Firestone Building Products Ultraply Tpo Code Approval Guide
User Manual:
Open the PDF directly: View PDF .
Page Count: 54
Download | |
Open PDF In Browser | View PDF |
UltraPly™ TPO Roof Systems Code Approval Guide May 24 t h 1|P age , 2018 You must verify the included assemblies in the charts below with the associated Firm’s (UL, FM, etc.). Not all the information included in the RoofNav assemblies will be listed in the charts below. You must verify that all assemblies meet Firestone Building Products warranty requirements with the associated regions technical team. Table of Contents Firestone V-Force Vapor Barrier System........................................................................................................ 5 Firestone Fully Adhered Systems................................................................................................................... 6 Firestone Fully Adhered Systems with UltraPly TPO SA membrane .............................................................. 6 Firestone Fully Adhered Systems with UltraPly TPO XR ................................................................................ 6 Firestone Mechanically Attached Systems ..................................................................................................... 7 UL Internal Fire Ratings ..................................................................................................................................... 8 UL Roof Deck Constructions and “P” Assemblies .......................................................................................... 8 Factory Mutual General Information................................................................................................................... 9 Ground Roughness Definitions ...................................................................................................................... 9 General Notations ........................................................................................................................................ 10 Field/Corner/Perimeter Definitions ............................................................................................................... 11 Perimeter and Corner Treatment of Adjoining BuildingsPrescriptive Enhancement Options: Perimeter and Corner .......................................................................................................................................................... 12 Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System ......................................................... 23 Firestone Fully Adhered Uplift Ratings – SBS Vapor Barrier System ............................................................... 24 New Construction, Concrete Deck, Adhesively Attached Insulation, With Cover Board................................ 24 Firestone Fully Adhered Uplift Ratings............................................................................................................. 24 New Construction, Concrete Deck, Adhesively Attached Insulation, Without Cover Board ........................... 24 New Construction, Concrete Deck, Adhesively Attached Insulation, With Cover Board................................ 25 New Construction, Cementitious Wood Fiber Deck, Adhesively Attached Insulation, With Cover Board ...... 27 New Construction, Steel or Concrete, Mechanically Attached Insulation without Cover Board ..................... 27 New Construction, Steel or Concrete, Insulation and/or Mechanically Attached Cover Board ...................... 29 New Construction, Steel Deck, Mechanically Attached Insulation, Without Cover Board .............................. 32 New Construction, Concrete Deck, Mechanically Attached Insulation, Without Cover Board ....................... 33 New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached Insulation .............. 33 New Construction, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation ........ 34 New Construction, Steel Deck, Insulation with Mechanically Attached Cover Board .................................... 35 New Construction, Concrete Deck, Insulation with Mechanically Attached Cover Board .............................. 35 New Construction, Steel or Concrete Deck, Insulation without Cover Board, UltraPly XR membrane .......... 35 New Construction, Steel or Concrete Deck, Insulation with Cover Board, UltraPly XR membrane ............... 36 New Construction, Concrete Deck, Adhered Cover Board Only, UltraPly XR membrane ............................. 39 New Construction, Concrete Deck, UltraPly XR membrane ......................................................................... 39 New Construction, Concrete, Vapor Barrier, Adhesively Attached Insulation, UltraPly XR membrane ......... 39 New Construction, Lightweight Insulated Concrete, UltraPly XR membrane ................................................ 40 May 24 t h 2|P age , 2018 Re-Cover Construction, Lightweight Insulating Concrete over Steel, Nailed Base Sheet with Adhesively Attached Insulation and Cover Board ........................................................................................................... 40 New Construction, Lightweight Insulating Concrete over Structural Concrete, with Adhesively Attached Insulation and Cover Board .......................................................................................................................... 40 Re-Cover Construction, Gypsum Deck, Adhesively Attached Insulation, Without Cover Board .................... 40 Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Cover Board ........................... 41 Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Cover Board........................... 41 Firestone Re-cover over Treated Wood Deck .................................................................................................. 42 Adhered Membrane ..................................................................................................................................... 42 Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane ............................... 42 New Construction, Steel, Mechanically Attached Insulation, Single Weld..................................................... 42 New Construction, Steel, Insulation with Cover Board, Single Weld ............................................................. 44 New Construction, Concrete, Insulation with Cover Board, Single Weld ...................................................... 46 Recover, Metal Building, Insulation with Cover Board .................................................................................. 46 Recover, Metal Building, Insulation without Cover Board ............................................................................. 48 Recover, Metal Building, Flute Filler with Cover Board ................................................................................. 48 Recover, Steel Deck, UltraPly TPO XR membrane, Single Weld ................................................................. 48 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System................................................. 49 Invisiweld System, Induction Welded ........................................................................................................... 49 Recover, Metal Building, Invisiweld System, Induction Welded .................................................................... 53 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld- S System ............................................ 53 Invisiweld-S System, Induction Welded ........................................................................................................ 53 Firestone Re-cover over Treated Wood Deck .................................................................................................. 53 InvisiWeld Attached Membrane.................................................................................................................... 53 May 24 t h 3|P age , 2018 Underwriters Laboratories (UL) External Fire Ratings All regional building codes and most local building code officials require that roofing systems meet minimum performance requirements when exposed to external fire sources. The accepted method for measuring external fire resistance is ASTM E-108. This test standard, and closely related standards such as Underwriters Laboratories UL-790 and Uniform Building Code 15-2, is used to determine the ability of a roof system to hinder the horizontal spread or vertical penetration of an external fire source. In accordance with these standards, all classified roof covering assemblies fall into one of the three following categories. • • • CLASS A: Includes roof coverings which are effective against severe fire exposures CLASS B: Includes roof coverings which are effective against moderate fire exposures CLASS C: Includes roof coverings which are effective against light fire exposures Noncombustible Roof Decks (NC): Steel, Concrete, Poured Gypsum – require testing for horizontal spread of flame. Combustible Roof Decks (C): Wood, Plywood, Tectum – require testing for both horizontal spread and vertical penetration of flame. The following information has been referenced from the UL Online Certification Directory document: TGFU.GuideInfo Certified gypsum wallboard, any thickness, may be included in any roofing system without adversely affecting the certification. Insulations may be attached to the deck with fasteners, hot mopping asphalt or certified adhesive. Certified insulated systems may be installed over existing certified insulated systems when: 1) the new system is certified for use with the existing roof insulation type (glass fiber, perlite, wood fiber, foamed plastic, etc.) 2) the total thickness of insulation in both systems does not exceed the maximum specified for the new system being applied. MAINTENANCE AND REPAIR SYSTEMS These roofing systems are composed of various types of roofing applications which are specifically limited for installation (recover) over existing roofing systems as specified. These systems may not meet certification requirements without being used over existing systems. Recovering may also be accomplished with certified new construction roofing systems where compatibility has been determined by test, by empirical data or by known performance properties of similar materials to the test methods. The following guidelines are provided to assist Authorities Having Jurisdiction in determining the suitability of a new construction roofing system as a recover system. Noncombustible Deck Construction: 1. Insulated roof systems may be utilized over any type of existing roof system and maintain its new construction rating when the roof deck is noncombustible. 2. Insulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing roof system and maintain its new construction rating when the roof deck is noncombustible. The insulation may be omitted from the recover system. 3. Uninsulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing uninsulated roof system and maintain its new construction rating when the roof deck is noncombustible. Combustible Deck Construction: 1. Insulated roof systems certified for use over combustible deck can be used over any type of existing roof system and maintain its new construction rating. 2. Insulated roof systems certified for use over noncombustible deck may be used over any type of Class A, B or C existing roof systems. The resultant Class will be the lesser rating of the existing system or the new construction (recover) system. 3. Uninsulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing uninsulated roof system and maintain its new construction rating. May 24 t h 4|P age , 2018 The class of roof covering required by each regional building code depends upon many factors, including the use and location of the building and the type of construction. The local building authority should always be consulted as to what the roofing assembly classification will need to be for each roofing project. It should be noted that these classifications apply to roofing assemblies, and NOT the roofing membrane. A roofing membrane that is classified as part of a Class A assembly when installed over a particular insulation may not qualify as part of a Class A assembly with another insulation. The “UL Item Number” in the following listings has been added as a service to those who have the UL Building Materials Directory. It identifies the UL listing from which our Code Approval Guide listing derives (e.g., “A,FA,23” means Class A, Fully Adhered, item number 23; “B,MA,04” means Class B, Mechanically Attached, item number 04, etc.). General Notations • PLEASE NOTE: Not all UL-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and attachment for the warranty desired must be followed. If a discrepancy occurs between this guide and UL Certifications, the published information located in the UL Certifications Directory at www.ul.com should be adhered to and utilized. Noncombustible decks Classifications are acceptable for use over combustible (15/32ʺ minimum plywood) decks when .5ʺ gypsum board or .25ʺ DensDeck® are used directly over the deck with all joints staggered 6ʺ minimum from plywood joints. The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for approval of assembly for warranty purposes. ISOGARD HG Insulation is an acceptable alterative to all insulations in the following Classifications except where DensDeck is stated. **Water Based Bonding Adhesive –P (WBBA-P) is an equivalent to Water Based Bonding Adhesive-R (WBBA-R) (no longer available**) ISOGARD GL™ is trademarked. • • • • • • NOTE: The UL assemblies listed below can be found on the UL Online Certification Direct report TGFU.R9516. You can click on the report number previously listed to open a hyperlink to the report. Firestone V-Force Vapor Barrier System Adhesive: Construction: Classification: UltraPly Bonding Adhesive, Single-Ply LVOC Bonding Adhesive or Water Based Bonding Adhesive S New or Tear-off See Note 1 Below UL Assembly Number Deck Vapor Barrier 1. NC (See NOTE) “V-Force”, self adhered 1A. C– 15/32 “V-Force”, self adhered 1B. C15/32 “V-Force”, self adhered Roofing System Any Insulated UL Classified modified bitumen system, BUR system, EPDM, or TPO membrane system. Insulation may be adhered with Firestone "I.S.O. Twin Pack", “I.S.O.Stick" or "I.S.O. Spray S". Insulation (Optional): Firestone ISOGARD GL – Any Thickness Barrier Board: 1” min. ISOGARD CG Roofing System: Any Insulated UL Classified modified bitumen system, BUR system, or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or TRE membrane system. Insulation may be adhered or mechanically attached with Firestone "I.S.O. Twin Pack™", "I.S.O. Twin Pack™ Green", "I.S.O.Stick™" or "I.S.O. Spray™ R" Insulation (Optional): Firestone ISOGARD GL – Any Thickness Barrier Board: ½ʺ thick DensDeck, DensDeck Prime Roofing System: Any Insulated UL Classified modified bitumen system, BUR system, or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or TRE membrane system. Insulation may be adhered or mechanically attached with Firestone "I.S.O. Twin Pack™", "I.S.O. Twin Pack Green", "I.S.O.Stick™" or "I.S.O. Spray™ R" Maximum Slope Class, Type See NOTE A/B/C, Mechanically Attached or Fully Adhered See NOTE A/B/C, Mechanically Attached or Fully Adhered See NOTE A/B/C, Mechanically Attached or Fully Adhered NOTE: Classification (A, B or C) and maximum incline will be the same as that for the currently Classified insulated system, currently limited to a noncombustible deck. May 24 t h 5|P age , 2018 Firestone Fully Adhered Systems Membrane: Adhesive: Construction: Classification: UL Assembly Number Deck Type 143. NC 88. C 144. NC 125. NC 123. C 160. NC 163. C 166/167. C/NC UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil) UltraPly Bonding Adhesive, Single-Ply LVOC Bonding Adhesive or Water Based Bonding Adhesive S New, Retrofit or Tear-off Class A Insulation Minimum Thickness Maximum Slope Membrane Class, Type Insulation (Optional): Firestone ISOGARD GL Any ¼ʺ UltraPly TPO A, Fully Adhered Barrier Board: DensDeck (Prime) Insulation (Optional): Any UL Classified, any thickness ½ʺ Any 2½ʺ UltraPly TPO A, Fully Adhered Any 2½ʺ UltraPly TPO A, Fully Adhered Any 7/16ʺ 1¼ʺ UltraPly TPO A, Fully Adhered --Any ½ʺ UltraPly TPO A, Fully Adhered Any ½ʺ ¼ʺ UltraPly TPO A, Fully Adhered Any ½ʺ ¼ʺ UltraPly TPO A, Fully Adhered Any Any 2ʺ UltraPly TPO A, Fully Adhered Insulation Assembly Lightweight Insulated (LWIC) or Structural Concrete Insulation: Any UL Classified, any thickness mechanically attached Cover Board: Oriented Strand Board (OSB) Slip Sheet: 2 layers VersaShield® FB-1S Insulation: Firestone ISOGARD GL, mechanically attached Insulation: Any Classified Poly I.S.O., any thickness Cover Board: Firestone ISOGARD CG or Firestone ISOGARD HD Insulation: Firestone ISOGARD GL Insulation: Firestone ISOGARD CG or Firestone ISOGARD HD Insulation: Firestone ISOGARD GL Barrier Board: DensDeck (Prime) Firestone Fully Adhered Systems with UltraPly TPO SA membrane Membrane: Adhesive: Construction: Classification: UltraPly TPO SA (45 or 60 mil) Self Adhered New, Retrofit or Tear-off Class A UL Assembly Number Deck Type Insulation Minimum Thickness Maximum Slope 182. NC/C Insulation (Optional): Any UL Classified any thickness Barrier Board: DensDeck Any ¼ʺ 2ʺ 184. NC/C* Insulation (Optional): ISOGARD CG Any ¼ʺ *DensDeck, ¼ʺ, required A, Fully Adhered 183. NC/C* Insulation: Firestone ISOGARD GL Any ¼ʺ *DensDeck, ¼ʺ, required A, Fully Adhered Insulation Assembly Class, Type NOTE A, Fully Adhered Firestone Fully Adhered Systems with UltraPly TPO XR Membrane: Adhesive: Construction: Classification: UL Assembly Number Deck Type 140. C 141. NC UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) or UltraPly TPO XR 135 (80 mil) XR Bonding Adhesive @ 90 sqft/gal New, Retrofit or Tear-off Class A Insulation Assembly Insulation (Optional): Any UL Classified any thickness Cover Board: G-P Gypsum DensDeck or DensDeck Prime Any Classified LWIC Insulation Minimum Thickness Any ¼ʺ 2ʺ coverage over internal insulation (if installed) Maximum Slope Class, Type 1ʺ A, Fully Adhered 1ʺ A, Fully Adhered May 24 t h 6|P age , 2018 Firestone Fully Adhered Systems with UltraPly TPO XR Membrane: Adhesive: Construction: Classification: Deck Type NC C/NC UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) or UltraPly TPO XR 135 (80 mil) Hot asphalt New, Retrofit or Tear-off Class A Insulation Assembly Insulation Minimum Thickness Maximum Slope Class, Type --- 1ʺ A, Fully Adhered Any ¼ʺ 1ʺ A, Fully Adhered None Insulation (Optional): Firestone ISOGARD™ GL Barrier Board: DensDeck or DensDeck Prime Firestone Fully Adhered Systems with UltraPly TPO XR Membrane: Adhesive: Construction: Classification: Deck Type UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) Firestone I.S.O. Spray or Firestone XR Stick Adhesive New, Retrofit or Tear-off Class A Insulation Assembly NC C* Insulation (Optional): Firestone ISOGARD GL, ISOGARD CG, or ISOGARD HD NC C* Structural Concrete or Lightweight Concrete decks only Insulation (Optional): Any UL Classified any thickness Barrier Board: DensDeck C/NC Insulation Minimum Thickness Maximum Slope NOTE Class, Type Any ¼ʺ *DensDeck, ¼ʺ A, Fully Adhered --- ¼ʺ / ½ʺ *DensDeck, ¼ʺ A, Fully Adhered Any ¼ʺ ½ʺ A, Fully Adhered Firestone Mechanically Attached Systems Membrane: Construction: Classification: UL Assembly Number Deck Type 58. C/NC 58A UltraPly TPO (45,60 or 80 mil), UltraPly Platinum (80 mil) New, Retrofit or Tear-off Class A Insulation Minimum Thickness Maximum Slope Membrane Insulation (Optional): Any UL Classified any thickness Cover Board: DensDeck Any ¼ʺ 4ʺ UltraPly TPO NC --- N/A 4ʺ UltraPly TPO 57. NC Insulation (Optional): Any UL Classified any thickness Cover Board: Glass fiber, wood fiber, or perlite Any ½ʺ ½ʺ UltraPly TPO 76. C/NC Two layers of “VersaShield Underlayment” or “VersaShield FB-2S --- 1ʺ UltraPly TPO 56. NC Any ½ʺ UltraPly TPO 63. C/NC --- ½ʺ UltraPly TPO 91. NC Any ½ʺ 1ʺ UltraPly TPO Insulation Assembly Insulation: Firestone ISOGARD GL Two or more layers of Atlas "FR 50", mechanically fastened Insulation (Optional): Any UL Classified any thickness Insulation (Required): Firestone ISOGARD CG May 24 Class, Type A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached A, Mechanically Attached t h 7|P age , 2018 UL Internal Fire Ratings To determine the resistance of a building to internal sources of fire, Underwriters Laboratories has conducted extensive testing and classification of wall, floor/ceiling and roof/ceiling assemblies. UL classified assemblies are rated according to the time in hours the assembly will contain a fire and still maintain structural integrity. Testing is conducted in accordance with UL Standard 263 (ASTM E-119), which is recognized by all major building codes. Roof/Ceiling Assemblies are listed in the UL Fire Resistance Directory - Vol. 1 under the prefix “P” and are classified by hourly fire rating according to the type of protection used to contain a fire: Assembly Protection Used P000 – P099 P200 – P299 P400 – P499 P500 – P599 P600 – P699 P700 – P799 P800 – P899 P900 – P999 Concealed grid suspended ceiling Exposed grid suspended ceiling Metal lathe (plaster) ceiling Gypsum board ceiling Miscellaneous fireproofing Spray-Applied Resistive Material Spray-Applied Resistive Material Unprotected concrete or composite decks It should be noted that the roof membrane forms only a small part of the total roof/ceiling assembly. For a structure to qualify for a “P” Assembly or Roof Deck Construction, all materials used to construct the assembly (including roof decking, ceiling materials, light fixtures, duct work and structural support members) must be UL classified and installed as described in the appropriate UL Directories. The insulations listed with each of the following “P” Assemblies are not, in most cases, the only UL accepted insulations for that assembly. Consult the UL Fire Resistance Directory - Vol. 1 for “P” Assembly information and the UL Roofing Materials and Systems Directory for Roof Deck Construction information, or call Firestone Technical Services for additional accepted insulations. UL has indicated on page 8 of the 2008 Fire Resistance Directory - Vol. 1 that "Class A, B or C roof coverings consisting of hot mopped or cold applied bituminous materials or a roof covering material classified under 'Roofing Membranes' (CHCI) may be applied directly to the concrete or wood surface of floor designs being used as roofs without a reduction of fire resistance ratings." They further state on page 8 that "Roof insulation is to be carefully controlled relative to manufacturer, type and thickness as specified. Less than the specified thickness could result in higher temperatures on the roof covering while a greater thickness of insulation could cause earlier structural failure. Classified polystyrene insulation, with a density of 5 pcf or less, may be placed on concrete floors or structural concrete roofs without reducing the assembly rating. When polyisocyanurate insulation is used over concrete in D 900 Series Designs, the unrestrained beam rating shall be increased by a minimum of ½ hour." Roof Deck Constructions are listed in the UL Roofing Materials and Systems Directory and are rated according to the interior flame spread of the assembly as compared to the flame spread of a typical built-up roof installed over a metal deck (UL 1256). Roof Deck Constructions may also be classified according to wind uplift performance. The fire rating of a UL Roof Deck Construction is similar to the Factory Mutual Class I internal fire (calorimeter) rating and they are deemed equivalent by the Model Building Code Agencies. UL Roof Deck Constructions and “P” Assemblies Deck Constructions (Tested in accordance to UL 1256) Firestone UltraPly TPO 96/120 roofing systems are classified for use in the following Deck Construction: 1, 2, 9, 14, 120, 123, 158, 200, 219, 237, 260, 276, 289, 292, 325, 374, 411, 412, 413, 419, 421, 440, 441, 444, 457, and 458. Consult Roof Deck Constructions (TGKX) in the UL Roofing Materials and Systems Directory, your regional technical coordinator or the Firestone Codes Department for an acceptable insulation for use in these constructions. “P” Assemblies (Designs) Firestone TPO 96/120 roofing systems are classified for use in the following hourly roof / ceiling designs. Ballasted, adhered or mechanically attached systems with or without optional wood fiber or mineral board insulation for use in Design numbers: P215, P216, P225, P227, P230, P231, P242, P246, P251, P259, P405, P406, P407, P410, P508, P510, P511,P512,P51 3, P514, P519, P701, P708, P709, P710, P711, P712, P717, P718, P719, P720, P722, P723, P725, P726, P727, P728,P 729, P730, P731, P732, P733, P734, P735, P737, P738, P739, P801, P810, P811, P815, P819, P822, P824, P825, P826, P827,P902, P903, P904, P905, P906, P907, P908, P909, P910, P911, P912, P913, P914, P915, P916, P917, P919, P92 0, P921, P922,P923, P925, P926, P927, P928, P929, P930, P931 Consult Fire Resistance Ratings (BXUV) in the UL Fire Resistance Directory, your regional technical coordinator or the Firestone Codes Department for an acceptable insulation, thickness and additional requirements. May 24 t h 8|P age , 2018 NOTE: The accepted insulation must be used in a UL Class A, B or C rated roofing assembly. UL acceptable system (e.g., adhering EPDM to Perlite or Fiberglass) listed for "P" design may not be approved for installation and warranty by Firestone. Contact Firestone Specifications and/or your Firestone Regional Technical Coordinator concerning acceptance. Factory Mutual General Information Factory Mutual Class 1 Approvals cover a wide range of testing of roofing products, including tests for fire resistance, corrosion resistance, fuel contribution and hail damage, Factory Mutual Approvals are known best for the uplift resistance, 1-60, 1-90, etc. afforded by an FM Approved roofing assembly: • • • FM 1-60 assemblies have been tested to withstand 60 psf air pressure applied for a period of one minute as well as one minute at the 30 and 45 psf levels. FM 1-90 assemblies have been tested to withstand 90 psf air pressure applied for a period of one minute as well as one minute at the 30, 45, 60 and 75 psf levels. Higher uplift ratings are possible based on the deck type and its attachment, fastener density and row spacing where applicable. When Factory Mutual 1-60 or 1-90 uplift ratings are specified, additional insulation attachment and reduced perimeter and corner batten (in-seam plate or batten for Reinforced Systems) spacing will/may be required. Consult the current edition of Factory Mutual Loss Prevention Data Sheets 1-28 and 1-29 for instructions for determining the required corner and perimeter dimensions and reduced spacing and increased fastener densities. Ground Roughness Definitions The descriptions below are based on information in ASCE 7. While information on this subject in the body of that standard is relatively brief, the designer must read the considerable additional information provided in the related commentary section of that document, particularly when then exposure is not obvious. For Exposure Category B to be used: A. The exposing terrain should include urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. B. Use of this exposure category should be limited to those areas for which the above terrain prevails in all directions for a distance of at least 2600′ (800 m) or 20 times the height of the building or other structure, whichever is greater. C. Limited openings in this terrain, such as small parking lots, roads, road intersections, playing fields, underdeveloped lots, and tree clearings can be tolerated. For openings that exceed 600′ (180 m) in total length measured radially from the building and 165′ [50 m] in width, use surface roughness exposure C. D. For buildings whose height is less than or equal to 30′ (9.1 m), the prevailing exposure B distance may be reduced to 1500′ (460 m). E. In cases where the difference between exposures B and C is not obvious, use exposure C. Exposure Category C NOTE: In cases where the difference between exposure B and C is not obvious, use exposure C. For Exposure Category C to be used: A. The exposing terrain should be open with scattered obstructions having heights generally less than 30′ (9 m), such as flat, open country and grasslands, and in all cases where exposures B and D do not apply. B. This also includes where surface roughness exposure B terrain is interrupted by clearings (parking lots, wide roads, road intersections, playing fields, underdeveloped lots, tree clearings, etc.) of greater than 600′ (180 m) in total length measured radially from the building and exceeding 165′ (50 m) in width. Exposure Category D NOTE: Some examples of D exposures include inland waterways, the Great Lakes, and coastal areas. See fig. 3.2.2.3 in FM Global LPDA 1-28 for examples of Exposure D requirements. For Exposure Category D to be used in determining the design wind pressure, all the following must be met: A. The terrain upwind of the structure must be flat, unobstructed areas or water surfaces including smooth mud flats, salt flats, and unbroken ice and is present in the upwind direction for a distance greater than approximately 5000′ (1500 m) or 20 times the building height, and B. The building must be within the greater of 600′ (180 m) or 20 times the building or structure height from the terrain (see Fig. 3.2.2.3), even if the terrain between the building and the terrain described in A. above would otherwise be considered Category B or C. May 24 t h 9|P age , 2018 Ballasted Systems Factory Mutual tests and rates only fully adhered and mechanically attached systems; Factory Mutual does accept the use of Ballasted Roof Systems on a job-to-job basis for FM insured clients. According to Mr. Edward J. Ward, Construction Standards Manager for Factory Mutual Research, “... the Factory Mutual system windstorm loss experience has been extremely favorable for Single-Ply ballasted roof systems. When these roofs are installed in accordance with (Factory Mutual) Loss Prevention Data Sheet 1-29, they are equally acceptable to Factory Mutual approved roofs.” General Notations PLEASE NOTE: Not all FM-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and attachment for the warranty desired must be followed. RoofNav® assemblies are summarized in the following tables; however, an assembly search should be conducted to confirm the attachment rates and requirements set for in the approval number. In all occasions, should a discrepancy occur between this guide and RoofNav, the published information located in the approval at www.roofnav.com should be adhered and utilized. Additionally, please be aware that the following assemblies typically are in reference to the field of the roof rating and attachment. Please refer to FM Global Loss Prevention Data Sheet 1-28 and 1-29 to determine the requirements for additional fastening requirements in the perimeter and corner. In all cases, when the project is Factory Mutual insured, please consult the FM agent assigned to the review of the project to ensure compliance. The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for approval of assembly for warranty purposes. It is acceptable to use multiple layers of FM Approved insulation, mechanically secured through all layers, provided all the following are true: • All layers are the same insulation; • The total insulation thickness is not greater than the maximum FM Approved thickness of the insulation; • The mechanical fastening and wind uplift rating are per the FM Approval of the top layer; and, • The roof cover/insulation/fastener combination is FM Approved. **Water Based Bonding Adhesive-P (WBBA-P) is the equivalent to Water Based Bonding Adhesive-S (WBBA-S)** May 24 10 | P a g e , 2018 t h Field/Corner/Perimeter Definitions The following diagram is direct form the FM Global Property Lost Prevention Data Sheet 1-28. This outlines how to calculate your perimeter and corner areas based on the building size and relative conditions. ©2015 Factory Mutual Insurance Company. All rights reserved. May 24 11 | P a g e , 2018 t h Perimeter and Corner Treatment of Adjoining Buildings May 24 12 | P a g e , 2018 t h Prescriptive Enhancement Options: Perimeter and Corner For all deck types, where roof covers are adhered to some combination of mechanically fastened insulation, cover board, or thermal barriers, prescriptive enhancements may be used for securement of the perimeter and corner areas, if one of the conditions below applies: • • • The building is in a non-hurricane prone region where the design wind speed does not exceed 90 mph and the roof height does not exceed 75 ft (23 m). Note the roof height is limited to 30 ft (9.1 m) if the building is located in surface roughness exposure D (see DS 1-28) and the building is partially enclosed. The recommended field of roof rating needed per DS 1-28 does not exceed Class 1-75 (3.6 kPa). The building is located in a non-hurricane prone area and the recommended field of the roof rating per Datasheet 1-28 does not exceed Class 1-90. For any of the three conditions above, increase the number of fasteners per board over the FM Approved field of the roof spacing by the following: • • • 50% minimum in the roof perimeter, but at least one fastener per 2 ft². (1 per 0.19 m²). It is not necessary to install fasteners closer than one per 1 ft² (1 per 0.09 m²). One fastener per 1 ft² (1 per 0.09 m²) in corner areas. Round up to the next whole number of fasteners, if necessary. May 24 13 | P a g e , 2018 t h You must verify the included assemblies in the charts below with the associated Firm’s (UL, FM, etc.). Not all the information included in the RoofNav assemblies will be listed in the charts below. You must verify that all assemblies meet Firestone Building Products warranty requirements with the associated regions technical team. NOTE: You must verify if any portion of the assembly needs primer. Most self adhering materials require primer to be used. Firestone Fully Adhered UltraPly TPO direct to ISOGARD GL – Mechanically Attached – Steel Deck Vapor Deck Insulation Membrane Membrane Uplift Barrier/Thermal Insulation Type Attachment Options Attachment Barrier 1-75 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-120 IF: 1 EF: A Slope: ¼ʺ 1-135 IF: 1 EF: A Slope: ¼ʺ 1-150 IF: 1 EF: A Slope: ¼ʺ 1-165 IF: 1 EF: A Slope: ¼ʺ 1-180 IF: 1 EF: A Slope: ¼ʺ Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 20-18-ga. 72ʺ span 33 ksi 22-ga. 69ʺ span 33 ksi Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding Water Based Bonding SA – Self Adhered Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered RoofNav Assembly Number 1ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Min. 12 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Min. 8 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 18 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 16 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 20 HD fasteners per 4' x 8' boards 45-80 mil. Single-Ply LVOC UltraPly TPO (1168) UltraPly TPO SA UltraPly Bonding EZ TPO SA – Self Adhered 400276-0-0 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 24 HD fasteners per 4' x 8' boards 45-80 mil. Single-Ply LVOC UltraPly TPO (1168) UltraPly TPO SA UltraPly Bonding EZ TPO SA – Self Adhered 400692-0-0 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 24 HD fasteners per 4' x 8' boards 45-80 mil. Single-Ply LVOC UltraPly TPO (1168) UltraPly TPO SA UltraPly Bonding EZ TPO SA – Self Adhered 400275-0-0 May 24 319480-0-0 400255-0-0 400214-0-0 400278-0-0 14 | P a g e , 2018 t h Firestone Fully Adhered UltraPly TPO direct to a Cover Board & Insulation Mech. Attached – Steel Deck Cover Vapor Barrier/ RoofNav Deck Cover Board Board/ Membrane Membrane Uplift Thermal Assembly Type /Insulation Insulation Options Attachment Barrier Number Attachment 1-60 IF: 1 EF: A Slope: 2.5ʺ Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck 1-60 IF: 1 EF: A Slope: 2.5ʺ 1-75 IF: 1 EF: A Slope: ½ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-105 IF: 1 EF: A Slope: 2.5ʺ 1-120 IF: 1 EF: A Slope: ¼ʺ 1-135 IF: 1 EF: A Slope: 2.5ʺ Cover Board: Min. ½ʺ DensDeck/Securock Insulation: 1.5ʺ-12ʺ Thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. ½ʺ Securock Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. ½ʺ Structodek HD® Insulation: 1ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. ¼ʺ DensDeck/ ½ʺ Securock Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: ½ʺ ISOGARD HD Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. ¼ʺ DensDeck Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: ½ʺ ISOGARD HD Insulation: 1.5ʺ- 4ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. ½ʺ DensDeck Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. 10 HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: Min. 10 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO EZ TPO 45-80 mil. UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding Water Based Bonding 112787-0-0 SA – Self Adhered 400815-0-0 Cover Board: Min. 12 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding Water Based Bonding 2063-0-0 Cover Board: Min. 12 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 209896-0-0 Cover Board: Min. 12 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 233370-0-0 Cover Board: Min. 18 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) SA – Self Adhered 394344-0-0 Cover Board: Min. 24 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 290589-0-0 Cover Board: Min. 18 HD fasteners per 4' x 8' boards Insulation: Loose Laid 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) SA – Self Adhered 395478-0-0 May 24 15 | P a g e , 2018 t h Continued Firestone Fully Adhered UltraPly TPO direct to a Cover Board & Insulation Mech. Attached – Steel Deck Vapor Barrier/ Cover Board/ RoofNav Deck Cover Board Membrane Membrane Uplift Thermal Insulation Assembly Type /Insulation Options Attachment Barrier Attachment Number Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Steel: 20-18-ga. 33 ksi 72ʺ span IF: 1 EF: A 22-ga. Slope: 2.5ʺ 33 ksi 64ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck 1-150 IF: 1 EF: A Slope: 2.5ʺ 1-150 IF: 1 EF: A Slope: ½ʺ 1-165 IF: 1 EF: A Slope: 2.5ʺ 1-165 IF: 1 EF: A Slope: ½ʺ 1-210 1-255 IF: 1 EF: A Slope: 2.5ʺ 1-300 IF: 1 EF: A Slope: ½ʺ Steel: 22-18-ga. 80 ksi 72ʺ span N/A Steel: 22-18-ga. 80 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Cover Board: Min. ½ʺ DensDeck Prime/Securock Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. 7/16ʺ OSB Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. ½ʺ DensDeck Prime/Securock Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. 7/16ʺ OSB Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. ½ʺ DensDeck Prime/Securock Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. ½ʺ DensDeck Prime Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Cover Board: Min. 7/16ʺ OSB Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Single-Ply LVOC Min. 24 HD 45-80 mil. Single-Ply LVOC fasteners per 4' x 8' UltraPly TPO (1168) 200412-0-0 boards UltraPly TPO SA UltraPly Bonding EZ TPO Insulation: SA – Self Adhered Loose Laid Cover Board: Min. 16 HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: Min. 32 HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: Min. 32 HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: Min. 32 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 45-80 mil. UltraPly TPO UltraPly TPO SA EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) 328645-0-0 UltraPly Bonding SA – Self Adhered 45-80 mil. UltraPly TPO Single-Ply LVOC (1168) UltraPly Bonding 328834-0-0 45-80 mil. UltraPly TPO EZ TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding 200414-0-0 Single-Ply LVOC Single-Ply LVOC (1168) 388009-0-0 Single-Ply LVOC (1168) UltraPly Bonding 171664-0-0 Insulation: Loose Laid Cover Board: Min. 32 HD 45-80 mil. fasteners per 4' x 8' UltraPly TPO boards Insulation: Loose Laid Cover Board: Min. 32 HD fasteners per 4' x 8' boards Insulation: Loose Laid 77830-0-0 45-80 mil. UltraPly TPO EZ TPO May 24 16 | P a g e , 2018 t h Firestone Fully Adhered UltraPly TPO direct to an Adhered Cover Board & Mech. Attached Insulation – Steel Deck Vapor Cover Board/ Membra RoofNav Deck Barrier/ Cover Board Membrane Uplift Insulation ne Assembly Type Thermal /Insulation Attachment Attachment Options Number Barrier 1-75 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ 1-165 IF: 1 EF: A Slope: ¼ʺ Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Cover Board: ½ʺ ISOGARD HD Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Cover Board: ½ʺ ISOGARD HD Steel: 22-16-ga. 33 ksi 72ʺ span Optional: ¼ʺ minimum DensDeck DensDeck Prime Securock Steel: 22-16-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼” DensDeck Steel: 22-16-ga. 33 ksi 72ʺ span Optional: ¼ʺ minimum DensDeck DensDeck Prime Securock Steel: 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Insulation: 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: ½ʺ ISOGARD HD Insulation: 2.2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: Min. ¼ʺ thick DensDeck Prime/ Securock Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. ½ʺ thick DensDeck Prime/ Securock Insulation: 2.2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: ½ʺ ISOGARD HD Insulation: 2ʺ-8ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: 12ʺ o.c. bead I.S.O. FIX I.S.O. Spray Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 8 HD Fasteners per 4' x 8' boards Cover Board: 12ʺ o.c. bead I.S.O. Spray Twin Pack Insulation: Min. 16 HD Fasteners per 4' x 8' boards Cover Board: 12ʺ o.c. bead I.S.O. Spray R Twin Pack Insulation: Min. 8 HD Fasteners per 4' x 8' boards Cover Board: 12ʺ o.c. bead I.S.O. Spray R Twin Pack Insulation: Min. 16 HD Fasteners per 4' x 8' boards Cover Board: 12ʺ o.c. bead I.S.O. Spray R Twin Pack Insulation: Min. 8 HD Fasteners per 4' x 8' boards Cover Board: 6ʺ o.c. bead I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 20 HD Fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 387410-0-0 Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 233373-0-0 Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 400915-0-0 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 400885-0-0 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 384613-0-0 Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 342142-0-0 45-80 mil. UltraPly TPO UltraPly TPO SA 45-80 mil. UltraPly TPO UltraPly TPO SA 45-80 mil. UltraPly TPO UltraPly TPO SA May 24 17 | P a g e , 2018 t h Continued Firestone Fully Adhered UltraPly TPO direct to an Adhered Cover Board & Mech. Attached Insulation – Steel Deck Vapor Barrier/ Cover Board/ RoofNav Deck Cover Board Membrane Membrane Uplift Thermal Insulation Assembly Type /Insulation Options Attachment Barrier Attachment Number 1-165 IF: 1 EF: A Slope: ¼ʺ Steel: 22-18-ga. 33 ksi 72ʺ span 1-165 IF: 1 EF: A Slope: 2.5ʺ 1-180 IF: 1 EF: A Slope: ¼ʺ 1-210 IF: 1 EF: A Slope: 2.5ʺ Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 20-18-ga. 33 ksi 72ʺ span 22-18 ga 80 ksi 72ʺ span Steel: 20-18-ga. 33 ksi 72ʺ span 22-18-ga. 80 ksi 72ʺ span 1-270 IF: 1 EF: A Slope: ¼ʺ Steel: 22-18 ga 80 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Optional: 4/6 mil. Polyethylene or V-Force SA over ¼ʺ DensDeck Cover Board: ½ʺ ISOGARD HD Insulation: 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. ½ʺ thick DensDeck Prime/ Securock Insulation: 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: ½ʺ ISOGARD HD Insulation: 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: Min. ½ʺ thick DensDeck Prime/ Securock Insulation: 2ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: ½ʺ ISOGARD HD Insulation: 2ʺ-8ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: 4ʺ o.c. bead I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 32 HD Fasteners per 4' x 8' boards Cover Board: 4ʺ o.c. bead I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 32 HD Fasteners per 4' x 8' board s Cover Board: 4ʺ o.c. bead I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 32 HD Fasteners per 4' x 8' boards Cover Board: 4ʺ o.c. bead I.S.O. Fix Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 32 HD Fasteners per 4' x 8' boards Cover Board: 4ʺ o.c. bead I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet Insulation: Min. 32 HD Fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 328437-0-0 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 328781-0-0 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered 320446-0-0 45-80 mil. UltraPly TPO 45-80 mil. UltraPly TPO Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered May 24 320420-0-0 342147-0-0 18 | P a g e , 2018 t h Firestone Fully Adhered UltraPly TPO, adhered Cover Board and/or Insulation – V-Force over MA DensDeck – Steel Deck Vapor Cover Board/ RoofNav Deck Barrier/ Cover Board Membrane Membrane Uplift Insulation Assembly Type Thermal /Insulation Options Attachment Attachment Number Barrier 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ V-Force Primer 22-16-ga. Min. ¼ʺ DensDeck 33 ksi Min. ½ʺ Securock 72ʺ span Min. 8 HD fasteners per 4' x 8' boards V-Force Primer 22-16-ga. Min.¼ʺ DensDeck 33 ksi Min. ½ʺ Securock 72ʺ span Min. 8 HD fasteners per 4' x 8' boards Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: ¼ʺ min. DensDeck Prime/ Securock Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 12ʺ o.c. bead I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet 45-80 mil. UltraPly TPO UltraPly TPO SA Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Bonding SA – Self Adhered Cover Board & Insulation: 12ʺ o.c. bead I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet 60-80 mil. UltraPly TPO Single-Ply LVOC (1168) Membrane Options Membrane Attachment RoofNav Assembly Number Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates 170476-0-0 Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates 266089-0-0 Sheet Size: 12' sheets Row Spacing: 142ʺ Fastener spacing: 6ʺ o.c. Firestone HD Fasteners and HD Seam Plates or Firestone HD Fasteners and Batten Strip (M) 335428-0-0 Firestone Mechanically Attached UltraPly TPO – Steel Deck Vapor Cover Board/ Deck Barrier/ Cover Board Uplift Insulation Type Thermal /Insulation Attachment Barrier 1-60 IF: 1 EF: A Slope: ¾ʺ 1-60 IF: 1 EF: A Slope: 1ʺ 1-60 IF: 1 EF: A Slope: ¾ʺ 20-16-ga. Optional: 33 ksi 4/6 mil. 72ʺ span Polyethylene 22-ga. or 33 ksi V-Force or 60ʺ span BASEGARD SA over 22-ga. ¼ʺ DensDeck 80 ksi 72ʺ span (possible primer) 20-16-ga. Optional: 33 ksi 4/6 mil. 72ʺ span Polyethylene 22-ga. or 33 ksi V-Force or 60ʺ span BASEGARD SA over 22-ga. ¼ʺ DensDeck 80 ksi 72ʺ span (possible primer) 18-ga. 33 ksi 72ʺ span 20-ga. Optional: 33 ksi 4/6 mil. 60ʺ span Polyethylene 22-ga. or 33 ksi V-Force or 48ʺ span BASEGARD SA over 20-ga. ¼ʺ DensDeck 80 ksi 72ʺ span (possible primer) 22-ga. 80 ksi 72ʺ span Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 5 HD fasteners per 4' x 8' boards Min. 5 HD fasteners per 4' x 8' boards Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO 45-80 mil. UltraPly TPO 45-80 mil. UltraPly TPO May 24 294762-0-0 307312-0-0 19 | P a g e , 2018 t h Continued Firestone Mechanically Attached UltraPly TPO – Steel Deck Vapor Cover Board/ Deck Barrier/ Cover Board Uplift Insulation Type Thermal /Insulation Attachment Barrier 1-60 IF: 1 EF: A Slope: 5ʺ 20-16-ga. 33 ksi 72ʺ span 22-ga. 33 ksi 60ʺ span 22-ga. 80 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force or BASEGARD SA over ¼ʺ DensDeck (possible primer) 1-75 IF: 1 EF: A Slope: 1ʺ 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene 1-75 IF: 1 EF: A Slope: 1ʺ 1-75 IF: 1 EF: A Slope: 1ʺ 1-75 IF: 1 EF: A Slope: 1ʺ 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene Optional: 4/6 mil. Polyethylene 22-18-ga. or 33 ksi V-Force or 72ʺ span BASEGARD SA over ¼ʺ DensDeck (possible primer) Optional: 4/6 mil. Polyethylene 22-18-ga. or 80 ksi V-Force 72ʺ span over ¼ʺ DensDeck (possible primer) Cover Board: ¼ʺ min. thick DensDeck, Prime or Securock Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG or 1.5ʺ-4ʺ ISOGARD HD Composite Insulation (Optional): 1.5ʺ-9.5ʺ ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Insulation: (2) 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. or 1.5ʺ-8ʺ ISOGARD HD Composite Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Min. 5 HD fasteners per 4' x 8' boards Min. 5 HD fasteners per 4' x 8' boards Membrane Options 45-80 mil. UltraPly TPO 45-80 mil. UltraPly TPO Membrane Attachment RoofNav Assembly Number Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates or Firestone HD Fasteners and Batten Strip (M) Sheet Size: 8' sheets Row Spacing: 90ʺ Fastener spacing: 12ʺ o.c. 264245-0-0 339042-0-0 Firestone HD Fasteners and HD Seam Plates Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO Sheet Size: 8' sheets Row Spacing: 90ʺ Fastener spacing: 12ʺ o.c. 338538-0-0 Firestone HD Fasteners and HD Seam Plates Min. 5 HD fasteners per 4' x 8' boards Min. 5 HD fasteners per 4' x 8' boards 60-80 mil. UltraPly TPO 60-80 mil. UltraPly TPO Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates May 24 375098-0-0 381672-0-0 20 | P a g e , 2018 t h Continued Firestone Mechanically Attached UltraPly TPO – Steel Deck Vapor Barrier/ Cover Board/ Deck Cover Board Uplift Thermal Insulation Type /Insulation Barrier Attachment 1-75 IF: 1 EF: A Slope: 1¾ʺ 22-18-ga. 80 ksi 72ʺ span 1-90 IF: 1 EF: A Slope: ¾ʺ 22-18-ga. 80 ksi 72ʺ span 1-90 IF: 1 EF: A Slope: 1ʺ 22-18-ga. 33 ksi 72ʺ span Optional: 4/6 mil. Polyethylene or V-Force over ¼ʺ DensDeck (possible primer) Optional: 4/6 mil. Polyethylene or V-Force or BASEGARD SA over ¼ʺ DensDeck (possible primer) Optional: 4/6 mil. Polyethylene or V-Force or BASEGARD SA over ¼ʺ DensDeck (possible primer) 1-90 IF: 1 EF: A Slope: 1ʺ 1-90 IF: 1 EF: A Slope: ¾ʺ 22-18-ga. 80 ksi 72ʺ span 18-19-ga. 33 ksi 72ʺ span 20-ga. 33 ksi 48ʺ span 20-ga. 80 ksi 72ʺ span 22-ga. 80 ksi 72ʺ span Optional: 4/6 mil. Polyethylene Optional: 4/6 mil. Polyethylene or V-Force or BASEGARD SA over ¼ʺ DensDeck (possible primer) Cover Board: ½ʺ Structodek HD ½ʺ FiberTop B Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. Insulation: 1.5ʺ -12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG or 1.5ʺ-4ʺ ISOGARD HD Composite Insulation (Optional): 1.5ʺ-9.5ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 5 HD fasteners per 1.5ʺ -12ʺ thick Min. 5 HD fasteners per 4' x 8' boards Membrane Options 60-80 mil. UltraPly TPO 45-80 mil. UltraPly TPO Membrane Attachment RoofNav Assembly Number Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates 381629-0-0 Sheet Size: 8' sheets Row Spacing: 90ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates 76897-0-0 Sheet Size: 78ʺ Row Spacing: 72ʺ Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO Fastener Spacing: 12ʺ o.c. 338363-0-0 Firestone HD Fasteners and HD Seam Plates Min. 5 HD fasteners per 4' x 8' boards Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO 45-80 mil. UltraPly TPO Sheet Size: 12' sheets Row Spacing: 71ʺ Fastener spacing: 12ʺ o.c. *Intermediate Batten Rows Firestone HD Fasteners and Batten Strip (M/P) Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 6ʺ o.c. 343386-0-0 166431-0-0 Firestone HD Fasteners and HD Seam Plates May 24 21 | P a g e , 2018 t h Continued Firestone Mechanically Attached UltraPly TPO – Steel Deck Vapor Cover Board/ Deck Barrier/ Cover Board Uplift Insulation Type Thermal /Insulation Attachment Barrier 1-90 IF: 1 EF: A Slope: ¾ʺ 1-90 IF: 1 EF: A Slope: 1ʺ 1-90 IF: 1 EF: A Slope: 1ʺ 1-105 IF: 1 EF: A Slope: 1ʺ 1-105 IF: 1 EF: A Slope: ¾ʺ Optional: 4/6 mil. Polyethylene 22-18-ga. or 80 ksi V-Force or 72ʺ span BASEGARD SA over ¼ʺ DensDeck (possible primer) Optional: 4/6 mil. Polyethylene 22-18-ga. or 80 ksi V-Force or 72” span BASEGARD SA over ¼ʺ DensDeck (possible primer) Optional: 4/6 mil. 22-16-ga. Polyethylene 33 ksi or 72ʺ span V-Force SA over ¼ʺ DensDeck (possible primer) Optional: 4/6 mil. 22-18-ga. Polyethylene 33 ksi or 72ʺ span V-Force SA over ¼ʺ DensDeck (possible primer) 18-ga. 33 ksi 54ʺ span 20-18-ga. 80 ksi 72ʺ span 22-ga. 80 ksi 60ʺ span Optional: 4/6 mil. Polyethylene or V-Force or BASEGARD SA over ¼ʺ DensDeck (possible primer) 1-105 IF: 1 EF: A Slope: 1ʺ 22-18-ga. 80 ksi 72ʺ span Optional: 4/6 mil. Polyethylene Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Min. 5 HD fasteners per 4' x 8' boards Membrane Options Membrane Attachment 45-80 mil. UltraPly TPO Sheet Size: 8' sheets Row Spacing: 90ʺ Fastener spacing: 12ʺ o.c. RoofNav Assembly Number 76731-0-0 Firestone HD Fasteners and HD Seam Plates *WIDE WELD* Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG or 1.5ʺ-12ʺ thick ISOGARD HD Composite Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO Min. 5 HD fasteners per 4' x 8' boards 60-80 mil. UltraPly TPO Min. 5 HD fasteners per 4' x 8' boards Min. 5 HD fasteners per 4' x 8' boards 45-80 mil. UltraPly TPO Sheet Size: 8' sheets Row Spacing: 90ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates Sheet Size: 10' sheets Row Spacing: 72ʺ Fastener spacing: 12ʺ o.c. RMA Strip w/ Firestone HD Fasteners and HD Seam Plates Sheet Size: 5' sheets Row Spacing: 54ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates Sheet Size: 10' sheets Row Spacing: 114ʺ Fastener spacing: 6ʺ o.c. 266129-0-0 382087-0-0 382086-0-0 3081-0-0 Firestone HD Fasteners and HD Seam Plates 45-80 mil. UltraPly TPO Sheet Size: 8' sheets Row Spacing: 90ʺ Fastener spacing: 6ʺ o.c. 364311-0-0 Firestone HD Fasteners and HD Seam Plates May 24 22 | P a g e , 2018 t h Continued Firestone Mechanically Attached UltraPly TPO – Steel Deck Vapor Cover Board/ Deck Barrier/ Cover Board Uplift Insulation Type Thermal /Insulation Attachment Barrier 1-105 IF: 1 EF: A Slope: 1ʺ 1-105 IF: 1 EF: A Slope: 1¾ʺ Membrane Attachment 381676-0-0 381634-0-0 Optional: 4/6 mil. 22-18-ga. Polyethylene 33 ksi or 72ʺ span V-Force SA over ¼ʺ DensDeck (possible primer) Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Min. 5 HD fasteners per 4' x 8' boards 60-80 mil. UltraPly TPO Sheet Size: 60' sheets Row Spacing: 54ʺ Fastener spacing: 12ʺ o.c. Optional: 4/6 mil. 22-18-ga. Polyethylene 33 ksi or 72ʺ span V-Force SA over ¼ʺ DensDeck (possible primer) Cover Board: ½ʺ Structodek HD ½ʺ FiberTop B Insulation: 1.5ʺ-12ʺ thick ISOGARD GL Tapered I.S.O. ISOGARD CG Min. 5 HD fasteners per 4' x 8' boards 60-80 mil. UltraPly TPO Firestone HD Fasteners and HD Seam Plates Sheet Size: 60' sheets Row Spacing: 54ʺ Fastener spacing: 12ʺ o.c. Firestone HD Fasteners and HD Seam Plates Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System Thermal Barrier Vapor Barrier Uplift Deck Type Insulation Assembly & Attachment System 1-90 IF: NC EF: A Slope: ¼ʺ Concrete: (New or recover) DensDeck/Securock, ¼ʺ min. 8 HD or Concrete Drive fasteners and plates per 4' x 8' boards Primed thermal barrier with VForce Concrete: Min. 2,500 psi Min. 2ʺ thick DensDeck, ¼ʺ min. Securock ½ʺ min. 8 HD or Concrete Drive fasteners and plates per 4' x 8' boards Primed thermal barrier with VForce 1-90 IF: NC EF: A Slope: ¼ʺ 1-525 Concrete: IF: NC Min. 2,500 psi EF: A Min. 2ʺ thick Slope: ¼ʺ None Primed substrate with V-Force None Primed substrate with V-Force 1-525 Concrete: IF: NC Min. 2,500 psi EF: A Min. 2ʺ thick Slope: ¼ʺ RoofNav Assembly Number Membrane Options ISOGARD GL, 1.5ʺ min., 4' x 4' boards, Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet 2 Layers - ISOGARD GL (Flat or Tapered), 1.5ʺ min., 4' x 4' boards, Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Cover Board: ISOGARD HD, ½ʺ min., 4' x 4' board, adhered with I.S.O.Stick, I.S.O. Spray or Twin Pack at 12ʺ o.c. Insulation: 2 Layers - ISOGARD GL, 1.5ʺ min., 4' x 4' boards, adhered with I.S.O.Stick, I.S.O. Spray or Twin Pack at 12ʺ o.c. Insulation: ISOGARD GL, 1.5ʺ min., 4' x 4' boards Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Membrane Options RoofNav Number UltraPly TPO: Single-Ply LVOC S.P. LVOC 1168 UltraPly Bonding UltraPly TPO SA 294593-0-0 UltraPly TPO Single-Ply LVOC S.P. LVOC 1168 UltraPly Bonding UltraPly TPO SA 294633-0-0 UltraPly TPO, FA with Single-Ply LVOC or UltraPly Bonding Adhesive Or UltraPly TPO SA 295461-0-0 UltraPly TPO: Single-Ply LVOC S.P. LVOC 1168 UltraPly Bonding 294948-0-0 May 24 23 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings – V-Force Vapor Barrier System Thermal Barrier Vapor Barrier Uplift Deck Type Insulation Assembly & Attachment System 1-525 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick None Primed substrate with V-Force None Primed substrate with V-Force 1-495 Concrete: Min. 2,500 psi Min. 2ʺ thick IF: NC EF: A Slope: 2.5ʺ Insulation: 2 Layers ISOGARD GL, 1.5ʺ min., 4' x 4' boards, Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Cover Board: DensDeck Prime or Securock ¼ʺ min. Insulation: ISOGARD GL, 1.5ʺ min., 4' x 4' boards Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Membrane Options RoofNav Number UltraPly TPO: Single-Ply LVOC S.P. LVOC 1168 UltraPly Bonding 294949-0-0 UltraPly TPO: Single-Ply LVOC S.P. LVOC 1168 UltraPly Bonding UltraPly TPO SA 295522-0-0 Firestone Fully Adhered Uplift Ratings – SBS Vapor Barrier System New Construction, Concrete Deck, Adhesively Attached Insulation, With Cover Board Vapor Cover Board RoofNav Deck Insulation and Cover Board Membrane Uplift Retarder/ and Insulation Membrane Assembly Type Attachment and Attachment Attachment Primer Attachment Number 1-465 IF: NC EF: A Slope: 2.5ʺ Cover Board: SBS Glass ¼ʺ min. Torch Base Cover DensDeck, SBS Poly Tapered Board/Insulation: Concrete: DensDeck Prime, Torch Base ISOGARD GL, 12ʺ o.c. beads Min. 2,500 or Securock, SBS Smooth 1.5ʺ min., 12ʺ o.c. I.S.O. Spray R psi 4' x 4' boards, 12ʺ Primer: beads of Twin Twin Pack Min. 2ʺ thick o.c. beads of Concrete Pack Adhesive I.S.O. Spray or Primer, Twin Pack Asphaltic Adhesive UltraPly TPO UltraPly Bonding Adhesive or Single-Ply LVOC Bonding Adhesive 233200-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, Without Cover Board Uplift Deck Type Insulation 1-555 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation (2 Layers): ISOGARD GL(Taper), 1ʺ (.5ʺ) min., ISOGARD GL, 1ʺ-36ʺ, 4' x 4' boards 1-330 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards 1-360 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards Insulation Attachment Adhered at 12ʺ o.c.: I.S.O. Spray R Membrane .045 mil. min. UltraPly membrane Adhered at 12ʺ o.c.: .060 mil. min. I.S.O. Twin Pack UltraPly Adhesive membrane Adhered with full application: I.S.O. Spray .045 mil. min. UltraPly membrane Membrane Attachment Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive May 24 RoofNav Assembly Number 304517-0-0 223517-0-0 80684-0-0 24 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, Without Cover Board Uplift Deck Type Insulation Insulation Attachment Membrane 1-360 IF: NC EF: A Slope: ¼ʺ 1-480 IF: NC EF: A Slope: ¼ʺ 1-540 IF: NC EF: A Slope: ¼ʺ 1-570 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 1.5ʺ-36ʺ 4' x 4' boards Adhered with full application: Hot Asphalt .060 mil. min. UltraPly membrane Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 1.5ʺ-36ʺ 4' x 4' boards Adhered at 8ʺ o.c.: I.S.O. Twin Pack Adhesive .045 mil. min. UltraPly membrane Concrete: Min. 2,500 psi Min. 2ʺ thick Primed: Asphaltic Insulation: ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards Adhered at 12ʺ o.c.: I.S.O.Stick Adhesive .045 mil. min. UltraPly membrane Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards Adhered at 4ʺ o.c.: I.S.O. Twin Pack Adhesive .045 mil. min. UltraPly membrane Membrane Attachment Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, With Cover Board Cover Board Cover Board and Membrane Uplift Deck Type and Insulation Membrane Insulation Attachment Attachment 1-120 IF: NC EF: A Slope: 2.5ʺ 1-270 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Primer: Asphaltic Concrete: Min. 2,500 psi Min. 2ʺ thick 1-255 IF: NC EF: A Slope: 2.5ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Cover Board: ¼ʺ min. DensDeck (Prime) or Securock Adhered at 12ʺ o.c.: Insulation: I.S.O.Stick Adhesive ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards Cover Board: ½ʺ ISOGARD HD Adhered at 12ʺ o.c.: Insulation: I.S.O. Spray R ISOGARD GL, 1.5ʺ-36ʺ, I.S.O. Twin Pack 4' x 4' boards Cover Board: ¼ʺ min. DensDeck Prime or Securock Adhered at 12ʺ o.c.: I.S.O. Spray R Insulation: I.S.O. Twin Pack ISOGARD GL (ISOGARD CG), ½ʺ-36ʺ, 4' x 4' boards RoofNav Assembly Number 245813-0-0 223518-0-0 228481-0-0 223523-0-0 RoofNav Assembly Number .045 mil. min. UltraPly membrane Single-Ply LVOC Bonding UltraPly Bonding Adhesive 228479-0-0 .045 mil. min. UltraPly membrane Water Based Bonding Adhesive 233376-0-0 .045 mil. min. UltraPly TPO or Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered 223524-0-0 May 24 25 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, With Cover Board Cover Board and Cover Board and Membrane Uplift Deck Type Insulation Membrane Insulation Attachment Attachment 1-90 IF: NC EF: A Slope: 2.5ʺ 1-255 IF: NC EF: A Slope: 2.5” 1-270 IF: NC EF: A Slope: ¼ʺ 1-270 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Cover Board: Min. 2ʺ thick ¼ʺ min. DensDeck Prime V-Force (req.): Insulation (Top): Self Adhered Tapered ISOGARD GL, ISOGARD CG, ½ʺ-4ʺ, Primer: 4' x 4' board Asphaltic Insulation (Bottom): Thermal (opt.): ISOGARD GL 1.5ʺ-8ʺ DensDeck, ¼ʺ min. Concrete: Min. 2,500 psi Min. 2ʺ thick Concrete: Min. 2,500 psi Min. 2ʺ thick Concrete: Min. 2,500 psi Min. 2ʺ thick 1-375 IF: NC EF: A Slope: 2.5ʺ 1-390 IF: NC EF: A Slope: 2.5ʺ 1-390 IF: NC EF: A Slope: 2.5ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Concrete: Min. 2,500 psi Min. 2ʺ thick Concrete: Min. 2,500 psi Min. 2ʺ thick Primer: Asphaltic 1-390 IF: NC EF: A Slope: 2.5ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Cover Board: ¼ʺ min. DensDeck Prime Insulation: ISOGARD GL, ISOGARD CG, ½ʺ-36ʺ, 4' x 4' boards Cover Board: ½ʺ ISOGARD HD Insulation: ISOGARD GL, 1.5ʺ36ʺ, 4' x 4' boards Cover Board: ½ʺ ISOGARD HD Insulation: ISOGARD GL, 1.5ʺ36ʺ, 4' x 4' boards Cover Board: ¼ʺ DensDeck Prime or Securock Insulation: ISOGARD GL, 1.5ʺ36ʺ, 4' x 4' boards Cover Board: ¼ʺ DensDeck Prime or Securock Insulation: ISOGARD GL, 1.5ʺ36ʺ, 4' x 4' boards Cover Board: ¼ʺ DensDeck Prime Or Securock Insulation: ISOGARD GL, 1.5ʺ36ʺ, 4' x 4' boards Cover Board: ¼ʺ DensDeck Prime or Securock Insulation: ISOGARD GL, 1.5ʺ36ʺ, 4' x 4' boards Cover Board and Top Insulation Adhered at 12ʺ o.c.: I.S.O. Fix II I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Bottom Insulation: Min. 16 HD fasteners per 4' x 8' boards Thermal: Loose Laid RoofNav Assembly Number .045 mil. min. UltraPly TPO or Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P Self Adhered 346005-0-0 Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack .045 mil. min. UltraPly TPO or Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered 223524-0-0 Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack .045 mil. min. UltraPly TPO Water Based Bonding Adhesive 233376-0-0 Adhered at 12ʺ o.c.: I.S.O.Stick/Twin Jet .045 mil. min. UltraPly TPO Water Based Bonding Adhesive 233380-0-0 Adhered at 8ʺ o.c.: I.S.O.Stick/Twin Jet .045 mil. min. UltraPly TPO Or Ultraply TPO SA Adhered at 12ʺ o.c.: I.S.O. Twin Pack .045 mil. min. UltraPly TPO I.S.O. Spray, full application Asphalt Attached, full application Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 223525-0-0 113754-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 135967-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 245811-0-0 May 24 26 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhesively Attached Insulation, With Cover Board Cover Board and Cover Board and Membrane Uplift Deck Type Insulation Membrane Insulation Attachment Attachment 1-495 IF: NC EF: A Slope: ½ʺ 1-600 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Primer: Asphaltic Concrete: Min. 2,500 psi Min. 2ʺ thick Cover Board: APA Rated OSB, 7/16ʺ min., 4' x 4' boards Insulation: ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards Cover Board: ½ʺ ISOGARD HD Insulation: ISOGARD GL, 1.5ʺ-36ʺ, 4' x 4' boards Adhered at 12ʺ o.c.: I.S.O.Stick/Twin Jet .045 mil. min. UltraPly TPO or Ultraply TPO SA Adhered at 12ʺ o.c.: I.S.O.Stick/Twin Jet .045 mil. min. UltraPly TPO or Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered RoofNav Assembly Number 228464-0-0 233379-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Cementitious Wood Fiber Deck, Adhesively Attached Insulation, With Cover Board Cover Board and RoofNav Deck Type Cover Board and Membrane Uplift Insulation Membrane Assembly (Vapor Retarder) Insulation Attachment Attachment Number 1-90 IF: 1 EF: A Slope: 2.5ʺ Cementitious Wood Fiber - Tectum Plank Min. thick: 2ʺ Max. span: 36ʺ Cover Board: ¼ʺ DensDeck Prime or Securock Insulation: ISOGARD GL, 1.5ʺ-12ʺ, 4' x 4' boards Adhered at 12ʺ o.c.: I.S.O. Fix Adhesive .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Mechanically Attached Insulation without Cover Board Deck Type (Vapor Insulation Membrane Uplift Retarder/Thermal Insulation Membrane Attachment Attachment Barrier) 1-90 IF: 1 EF: A Slope: ¼ʺ Steel: 22-16-ga. 33 ksi 72ʺ span 1-90 IF:NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 PSI Min. 2ʺ thick Insulation: ISOGARD GL, 1.5ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: V-Force (SA) w/Primer or SBS Torch Attached with 12 AP or HD fasteners per 4' x 8' boards Attached with 12 HD fasteners per 4' x 8' boards 112012-0-0 RoofNav Assembly Number .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P 2113-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P 2106-0-0 May 24 27 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Mechanically Attached Insulation without Cover Board Deck Type (Vapor Insulation Membrane Uplift Retarder/Thermal Insulation Membrane Attachment Attachment Barrier) 1-90 IF: 1 EF: A Slope: ¼ʺ Steel: 22-16-ga. 33 ksi 72ʺ span 1-120 IF: 1 EF: A Slope: ¼ʺ 1-180 IF: 1 EF: A Slope: ¼ʺ Steel: 22-18-ga. 33 ksi 72ʺ span Steel (WR): 20-18-ga. WR 33 ksi 72ʺ span 22-18-ga. 80 ksi 72ʺ span 1-120 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick 1-150 IF: 1 EF: A Slope: ¼ʺ 1-225 IF: 1 EF: A Slope: ¼ʺ Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 18-ga. 33 ksi 72ʺ span 22-18-ga. 80 ksi 72ʺ span Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) or SBS Torch Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck RoofNav Assembly Number .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 191607-0-0 Attached with 18 AP or HD fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 127787-0-0 Attached with 24 AP or HD fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 233194-0-0 Attached with 20 Concrete Drive or HD fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Water Based Bonding Adhesive 296301-0-0 Attached with 20 AP or HD fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 233195-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 228346-0-0 Attached with 8 AP or HD fasteners per 4' x 8' boards Attached with 32 AP or HD fasteners per 4' x 8' boards May 24 28 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation and/or Mechanically Attached Cover Board Deck Type Cover Board (Vapor Cover Board/ Membrane Uplift and Insulation Membrane Retarder/Therma Insulation Attachment Attachment l Barrier) 1-75 IF: 1 EF: A Slope: ½ʺ Steel: 22-16-ga. 33 ksi 72ʺ span 1-75 IF: NC EF: A Slope: ¾ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Steel: 22-16-ga. 33 ksi 72ʺ span 1-90 IF: 1 EF: A Slope: 2.5ʺ Steel: 22-16-ga. 33 ksi 72ʺ span 1-90 IF: NC EF: A Slope: 2.5ʺ Cover Board: ½ʺ min. Structodek HD Fiberboard HD Insulation: ISOGARD GL, 1.5ʺ-12ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ Cover Board: ½ʺ min. Structodek HD Fiberboard HD Insulation: ISOGARD GL, 2ʺ-12ʺ thick, 4' x 8' boards Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Concrete: Min. 2,500 psi Min. 2ʺ thick Cover Board: DensDeck, ¼ʺ min. Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: DensDeck, ¼ʺ min. Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: DensDeck, ¼ʺ min. Securock, ¼ʺ min. Insulation: ISOGARD GL, 1ʺ-12ʺ Cover Board: 12 AP or HD fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P 2063-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P 2061-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P 112795-0-0 .045 mil. min. UltraPly TPO Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P Self Adhered 209896-0-0 .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P 2064-0-0 Insulation: Loose Laid Cover Board: 12 HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: 16 AP or HD fasteners per 4' x 8' board Insulation: Loose Laid Cover Board: 12 AP or HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: 18 AP or HD fasteners per 4' x 8' boards Insulation: Loose Laid RoofNav Assembly Number May 24 29 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation and/or Mechanically Attached Cover Board Deck Type (Vapor Cover Board Cover Board/ Membrane Uplift Retarder/Thermal and Insulation Membrane Insulation Attachment Barrier) Attachment 1-150 IF: 1 EF: A Slope: 2.5ʺ 1-210 IF: 1 EF: A Slope: 2.5ʺ 1-90 IF: 1 EF: A Slope: ½ʺ 1-105 IF: 1 EF: A Slope: ½ʺ 1-150 IF: 1 EF: A Slope: ½ʺ Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 22-18-ga. 33 ksi 72ʺ span 22-ga. 33 ksi 64ʺ span 22-18-ga. 80 ksi 72ʺ span Steel: 20-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Cover Board: DensDeck, ½ʺ min. Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: DensDeck, ½ʺ min. Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: APA Rated OSB 7/16ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: APA Rated OSB 7/16ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: APA Rated OSB 7/16ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: 24 AP or HD fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: 32 AP or HD fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Insulation: Loose Laid Cover Board: 12 HD ISOGARD HG Fasteners per 4' x 8' boards Insulation: Loose Laid Cover Board: 16 HD ISOGARD HG Fasteners per 4' x 8' boards Insulation: Loose Laid 200412-0-0 200414-0-0 Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P Self Adhered 136153-0-0 .045 mil. min. UltraPly TPO Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Water Based P Self Adhered 136151-0-0 .045 mil. min. UltraPly TPO Ultraply TPO SA Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered 77830-0-0 .045 mil. min. UltraPly TPO Insulation: Loose Laid Cover Board: 20 HD ISOGARD HG Fasteners per 4' x 8' boards RoofNav Assembly Number May 24 30 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation and/or Mechanically Attached Cover Board Deck Type (Vapor Cover Board Cover Board/ Membrane Uplift Retarder/Thermal and Insulation Membrane Insulation Attachment Barrier) Attachment 1-300 IF: 1 EF: A Slope: ½ʺ 1-90 IF: 1 EF: A Slope: ½ʺ 1-105 IF: 1 EF: A Slope: ½ʺ 1-165 IF: 1 EF: A Slope: ½ʺ 1-300 IF: 1 EF: A Slope: ½ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ Steel (WR): 22-18-ga. 80 ksi 72ʺ span Steel (WR): 20-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 18-ga. 33 ksi 70ʺ span 20-ga. 33 ksi 60ʺ span 22-18-ga. 80 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Cover Board: APA Rated OSB 7/16ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: 32 HD ISOGARD HG Fasteners per 4' x 8' boards Insulation: Loose Laid Insulation: ISOGARD HG, 2ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: 12 HD ISOGARD HG Fasteners per 4' x 8' boards Insulation: ISOGARD HG, 2ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: 20 HD ISOGARD HG Fasteners per 4' x 8' boards Insulation: ISOGARD HG, 1.5ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: 32 HD ISOGARD HG Fasteners per 4' x 8' boards Insulation: ISOGARD HG, 1.5ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: ISOGARD HD, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck .045 mil. min. UltraPly TPO Insulation: 32 HD ISOGARD HG Fasteners per 4' x 8' boards Cover Board: 12 HD or AP Fasteners per 4' x 8' boards Insulation: Loose Laid RoofNav Assembly Number Single-Ply LVOC Bonding 1168 171664-0-0 UltraPly Bonding Adhesive Single-Ply LVOC Bonding .045 mil. min. Single-Ply LVOC UltraPly TPO Bonding 1168 136363-0-0 Ultraply TPO UltraPly Bonding SA Adhesive Water Based P Self Adhered Single-Ply LVOC Bonding .045 mil. min. Single-Ply LVOC UltraPly TPO Bonding 1168 136362-0-0 Ultraply TPO UltraPly Bonding SA Adhesive Water Based P Self Adhered .045 mil. min. UltraPly TPO .045 mil. min. UltraPly TPO Single-Ply LVOC Bonding 1168 328832-0-0 UltraPly Bonding Adhesive Single-Ply LVOC Bonding 1168 171662-0-0 UltraPly Bonding Adhesive Single-Ply LVOC Bonding .045 mil. min. Single-Ply LVOC UltraPly TPO Bonding 1168 233370-0-0 Ultraply TPO UltraPly Bonding SA Adhesive Self Adhered May 24 31 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete, Insulation and/or Mechanically Attached Cover Board Deck Type (Vapor Cover Board Cover Board/ Membrane Uplift Retarder/Thermal and Insulation Membrane Insulation Attachment Barrier) Attachment Steel: 22-16-ga. 33 ksi 72ʺ span Cover Board: ISOGARD HD, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Steel: 22-18-ga. 33 ksi 72ʺ span Cover Board: DensDeck Prime, ¼ʺ min. Insulation: ISOGARD GL, 2ʺ-12ʺ Steel: 22-16-ga. 33 ksi 72ʺ span Cover Board: DensDeck, DensDeck Prime, Securock ¼ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Steel: 22-16-ga. 33 ksi 72ʺ span Insulation (Top): ISOGARD GL, 1.5ʺ-4ʺ Insulation (Bottom): ISOGARD GL, 1.5ʺ-4ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ Cover Board: Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack Insulation: 16 HD or AP Fasteners per 4' x 8' boards RoofNav Assembly Number Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive Self Adhered 233373-0-0 Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 Water Based P 388285-0-0 Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 233196-0-0 Single-Ply LVOC Bonding Single-Ply LVOC Bonding 1168 UltraPly Bonding Adhesive 230423-0-0 Insulation Attachment Membrane RoofNav Number Insulation: 8 HD or AP Fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO SA 373219-0-0 Insulation: 18 HD or AP Fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO SA 373217-0-0 Insulation: 24 HD or AP Fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO SA 373246-0-0 Cover Board: Adhered at 12ʺ o.c.: I.S.O. Twin Pack Insulation: 8 HD or AP Fasteners per 4' x 8' boards Cover Board: Adhered at 12ʺ o.c.: I.S.O. Spray R I.S.O. Twin Pack Insulation: 16 HD or AP Fasteners per 4' x 8' boards Insulation (Top): Adhered at 12ʺ o.c.: I.S.O. Twin Pack Insulation (Bottom): 16 HD or AP Fasteners per 4' x 8' boards .045 mil. min. UltraPly TPO Ultraply TPO SA .045 mil. min. UltraPly TPO .045 mil. min. UltraPly TPO .045 mil. min. UltraPly TPO Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Mechanically Attached Insulation, Without Cover Board Uplift 1-90 IF: 1 EF: A Slope: ¼ʺ 1-120 IF: 1 EF: A Slope: ¼ʺ 1-165 IF: 1 EF: A Slope: ¼ʺ Deck Type Steel: 22-16-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Insulation Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼” DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼” DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck May 24 32 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Concrete Deck, Mechanically Attached Insulation, Without Cover Board Uplift Deck Type 1-90 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick 1-150 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick 1-300 IF: NC EF: A Slope: ¼ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation Insulation: ISOGARD GL, 1.25ʺ-12ʺ Optional: V-Force (SA) Primer or SBS Torch Insulation: ISOGARD GL, 2ʺ-4ʺ Optional: ISOGARD GL, ½ʺ-12ʺ Or V-Force (SA) Primer or SBS Torch Insulation (Top): ISOGARD GL, 2ʺ-4ʺ Optional (Bottom): ISOGARD GL, ½ʺ-12ʺ Optional: V-Force (SA) Primer or SBS Torch Insulation Attachment Insulation: 12 Concrete Drive or HP Fasteners per 4' x 8' boards Insulation: 20 Concrete Drive or HP Fasteners per 4' x 8' boards Insulation: 32 Concrete Drive or HP Fasteners per 4' x 8' boards Membrane .045 mil. min. UltraPly TPO SA .045 mil. min. UltraPly TPO SA .045 mil. min. UltraPly TPO SA RoofNav Number 373390-0-0 373397-0-0 373398-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached Insulation Uplift 1-60 IF: 1 EF: A Slope: ¼ʺ 1-75 IF: 1 EF: A Slope: ¼ʺ Deck Type Steel: 22-18-ga. 33 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Insulation Insulation (Top): ISOGARD GL, 1.5ʺ-8ʺ Insulation (Bottom): ISOGARD GL, 1.5ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation (Top): ISOGARD GL, 1.5ʺ-8ʺ Insulation (Bottom): ISOGARD GL, 2ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation Attachment (Top) Adhered at 12ʺ o.c.: I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet (Bottom): 12 AP or HD fasteners and plates per 4' x 8' boards Optional Vapor/Thermal: Loose Laid (Top) Adhered at 12ʺ o.c.: I.S.O. Fix I.S.O. Spray R Twin Pack I.S.O.Stick/Twin Jet (Bottom): 8 AP or HD fasteners and plates per 4' x 8' boards Optional Vapor/Thermal: Loose Laid Membrane .045 mil. min. UltraPly TPO SA .045 mil. min. UltraPly TPO SA May 24 RoofNav Number 373224-0-0 373230-0-0 33 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Mechanically Attached Insulation, Adhesively Attached Insulation Uplift 1-90 IF: 1 EF: A Slope: ¼ʺ 1-150 IF: 1 EF: A Slope: ¼ʺ Deck Type Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-18-ga. 33 ksi 72ʺ span Insulation Insulation Attachment Insulation (Top): ISOGARD GL, 1.5ʺ-4ʺ Insulation (Bottom): ISOGARD GL, 2.25ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation (Top): ISOGARD GL, ¼ʺ Insulation (Bottom): ISOGARD GL, 1.5ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck (Top) Adhered at 12ʺ o.c.: I.S.O. Fix Twin Pack I.S.O.Stick/Twin Jet (Bottom): 8 AP or HD fasteners and plates per 4' x 8' boards Optional Vapor/Thermal: Loose Laid (Top) Adhered at 12ʺ o.c.: Twin Pack (Bottom): 20 AP or HD fasteners and plates per 4' x 8' boards Optional Vapor/Thermal: Loose Laid Membrane .045 mil. min. UltraPly TPO SA .045 mil. min. UltraPly TPO SA RoofNav Number 373236-0-0 373245-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Concrete Deck, Mechanically Attached Insulation, Adhesively Attached Insulation Uplift 1-90 IF: NC EF: A Slope: ¼” Deck Type Insulation Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: Firestone ISOGARD GL, 1.5ʺ-4ʺ thick Insulation (Bottom): ISOGARD GL, 2.25ʺ-8ʺ Optional: V-Force or SBS Torch Insulation: Firestone ISOGARD GL, 1ʺ-4ʺ Thick 1-255 IF: NC EF: A Slope: ¼” Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation (Bottom): ISOGARD GL, 2ʺ-8ʺ Optional: V-Force or SBS Torch Insulation Attachment (Top): Adhered at 12ʺ o.c.: I.S.O. Fix I.S.O. Twin Pack I.S.O.Stick/Twin Jet (Bottom): 8 HD fasteners and plates per 4' x 8' boards Optional: Self Adhered or Torched (Top): Adhered at 4ʺ o.c.: I.S.O. Fix I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet (Bottom): 32 HD or Concrete Drive fasteners and plates 4' x 8' boards Optional: Self Adhered or Torched Membrane .045 mil. min. UltraPly TPO SA .045 mil. min. UltraPly TPO SA May 24 RoofNav Number 373371-0-0 373389-0-0 34 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Steel Deck, Insulation with Mechanically Attached Cover Board Cover Cover Board/Insulation Uplift Deck Type Board/Insulation Attachment 1-90 IF: 1 EF: A Slope: 2.5 1-90 IF: 1 EF: A Slope: 2.5 Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Cover Board: DensDeck, ¼ʺ min. or Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: ISOGARD HD, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Membrane RoofNav Number Cover Board: 12 HD or AP fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Loose Laid V-Force – Self Adhered .045 mil. min. UltraPly TPO AS or Ultraply TPO (SP LVOC, SP LVOC 1168, UltraPly, WB P) 271664-0-0 Cover Board: 12 HD or AP fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Loose Laid V-Force – Self Adhered .045 mil. min. UltraPly TPO SA or Ultraply TPO (SP LVOC, SP LVOC 1168, UltraPly) 233370-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly TPO SA membrane New Construction, Concrete Deck, Insulation with Mechanically Attached Cover Board Uplift 1-90 IF: NC EF: A Slope: ¼ʺ 1-90 IF: NC EF: A Slope: ¼ʺ Deck Type Concrete: Min. 2,500 psi Min. 2ʺ thick Concrete Optional: V-Force and DensDeck or Polyethylene Cover Board/Insulation Cover Board/ Insulation Attachment Cover Board: ISOGARD HD, 1ʺ min. Cover Board: 18 Concrete Drive or HD fasteners per 4' x 8' boards Insulation: ISOGARD GL, 1.5ʺ-4ʺ Cover Board: Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: Loose Laid Cover Board: 8 Concrete Drive or HD fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Loose Laid V-Force – Self Adhered Membrane RoofNav Number .045 mil. min. UltraPly TPO AS or Ultraply TPO (SP LVOC, SP LVOC 1168, UltraPly, WB P) 290613-0-0 045 mil. min. UltraPly TPO SA or Ultraply TPO (SP LVOC, SP LVOC 1168, UltraPly, WB P) 372640-0-0 Firestone Fully Adhered Uplift Ratings – UltraPly XR 100 and XR 115 membrane New Construction, Steel or Concrete Deck, Insulation without Cover Board, UltraPly XR membrane Membrane Uplift Deck Type Insulation Insulation Attachment and Attachment 1-90 IF: 1 EF: A Slope: ½ʺ Steel: 22-1-ga. 33 ksi 72ʺ span Insulation: ISOGARD GL, 1.5ʺ-4ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: 16 HD or AP fasteners per 4' x 8' boards Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid RoofNav Assembly Number UltraPly XR: 100, 115 or 135 12ʺ o.c. ribbons: I.S.O. Spray R XR Stick May 24 289254-0-0 35 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings – UltraPly XR 100 and XR 115 membrane New Construction, Steel or Concrete Deck, Insulation without Cover Board, UltraPly XR membrane Membrane Uplift Deck Type Insulation Insulation Attachment and Attachment 1-90 IF: NC EF: A Slope: ½ʺ 1-165 IF: 1 EF: A Slope: ½ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Steel: 22-18-ga. 33 ksi 72ʺ span 1-165 IF: NC EF: A Slope: ½ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick 1-285 IF: NC EF: A Slope: ½ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick 1-285 IF: 1 EF: A Slope: ½ʺ Steel: 18-ga.,33 ksi 72ʺ span 22-18-ga. 80 ksi 72ʺ span Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: 16 Concrete Drive or HD fasteners per 4' x 8' boards Optional: V-Force – Self Adhered SBS Torch - Torched Insulation: 20 HD or AP fasteners per 4' x 8' boards Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid Insulation: 20 Concrete Drive or HD fasteners per 4' x 8' boards Optional: V-Force – Self Adhered SBS Torch - Torched Insulation: 32 Concrete Drive or HD fasteners per 4' x 8' boards Optional: V-Force – Self Adhered SBS Torch - Torched Insulation: 32 HD or AP fasteners per 4' x 8' boards Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid UltraPly XR 100, 115 or 135 12ʺ o.c. ribbons: I.S.O. Spray R XR Stick 1-75 IF: 1 EF: A Slope: 1ʺ 1-90 IF: 1 EF: A Slope: 4ʺ Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Cover Board: 15 HD or AP fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid Cover Board: 12 HD or AP fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid 289250-0-0 UltraPly XR 100, 115 or 135 6ʺ o.c. ribbons: I.S.O. Spray R XR Stick 292119-0-0 UltraPly XR 100, 115 or 135 6ʺ o.c. ribbons: I.S.O. Spray R XR Stick UltraPly XR 100, 115 or 135 4ʺ o.c. ribbons: I.S.O. Spray R XR Stick 289292-0-0 289295-0-0 UltraPly XR 100, 115 or 135 4ʺ o.c. ribbons: I.S.O. Spray R XR Stick Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete Deck, Insulation with Cover Board, UltraPly XR membrane Membrane Cover Board/ Cover Board/ Uplift Deck Type and Insulation Insulation Attachment Attachment Cover Board: DensDeck, ¼ʺ min. or Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: DensDeck, ¼ʺ min. or Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene Or V-Force (SA) over ¼ʺ DensDeck RoofNav Assembly Number 292137-0-0 RoofNav Assembly Number UltraPly XR 100 or 115 Full Coverage: Water Based Bonding Adhesive 243485-0-0 UltraPly XR 100 or 115 Full Coverage: XR Bonding Adhesive May 24 243482-0-0 36 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete Deck, Insulation with Cover Board, UltraPly XR membrane Membrane Cover Board/ Cover Board/ Uplift Deck Type and Insulation Insulation Attachment Attachment 1-90 IF: NC EF: A Slope: 2ʺ 1-90 IF: 1 EF: A Slope: ½ʺ 1-90 IF: 1 EF: A Slope: ½ʺ 1-90 IF: NC EF: A Slope: ½ʺ 1-120 IF: NC EF: A Slope: 2ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Concrete: Min. 2,500 psi Min. 2ʺ thick Concrete: Min. 2,500 psi Min. 2ʺ thick Cover Board: DensDeck, ¼ʺ min. or Securock, ¼ʺ min. Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Cover Board: ISOGARD HD, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: APA Rated OSB, 7/16ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: APA Rated OSB, 7/16ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Cover Board: DensDeck, ½ʺ min. or Securock, ½ʺ min. Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Cover Board: 16 Concrete Drive or HD fasteners per 4' x 8' boards Insulation: Loose Laid Optional: V-Force – Self Adhered or SBS Torch - Torched Cover Board: 15 HD or AP fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid Cover Board: 16 HD or AP fasteners per 4' x 8' boards Insulation: Loose Laid Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid Cover Board: 16 Concrete Drive or HD fasteners per 4' x 8' boards Insulation: Loose Laid Optional: V-Force – Self Adhered or SBS Torch - Torched Cover Board: 4' x 4' boards attached w/ 6ʺ o.c. beads: I.S.O. Fix I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Insulation: 20 Concrete Drive or HD fasteners per 4' x 8' board Optional: V-Force – Self Adhered or SBS Torch - Torched RoofNav Assembly Number UltraPly XR 100, 115 or 135 12ʺ o.c. ribbons: I.S.O. Spray R XR Stick 292001-0-0 UltraPly XR 100, 115 or 135 320509-0-0 12ʺ o.c. ribbons: I.S.O. Spray R XR Stick UltraPly XR 100, 115 or 135 12ʺ o.c. ribbons: I.S.O. Spray R XR Stick 291981-0-0 UltraPly XR 100, 115 or 135 12ʺ o.c. ribbons: I.S.O. Spray R XR Stick 289274-0-0 UltraPly XR 100, 115 or 135 6ʺ o.c. ribbons: I.S.O. Spray R XR Stick May 24 289300-0-0 37 | P a g e , 2018 t h Continued Firestone Fully Adhered Uplift Ratings New Construction, Steel or Concrete Deck, Insulation with Cover Board, UltraPly XR membrane Membrane Cover Board/ Cover Board/ Uplift Deck Type and Insulation Insulation Attachment Attachment Cover Board: DensDeck, ½ʺ min. or Securock, ½ʺ min. 1-120 IF: 1 EF: A Slope: 2ʺ Steel (WR): 22-18-ga. 33 ksi 72ʺ span Insulation: ISOGARD GL, 1.5ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: ISOGARD HD, ½ʺ min. 1-165 IF: 1 EF: A Slope: ½ʺ Steel (WR): 22-18-ga. 33 ksi 72ʺ span Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Cover Board: ISOGARD HD, ½ʺ min. 1-165 IF:NC EF: A Slope: ½ʺ 1-255 IF:NC EF: A Slope: 2ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Cover Board: DensDeck, ½ʺ min. or Securock, ½ʺ min. Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: ISOGARD GL, 2ʺ-12ʺ Optional: V-Force (SA) or SBS Torch Cover Board: 4' x 4' boards attached w/6ʺ o.c. beads I.S.O. Fix I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Insulation: 20 HD or AP fasteners per 4' x 8' board Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid Cover Board: 4' x 4' boards attached w/6ʺ o.c. beads I.S.O. Fix I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Insulation: 20 HD or AP fasteners per 4' x 8' boards Optional: Poly - Loose Laid V-Force – Self Adhered DD – Loose Laid Cover Board: 4' x 4' boards attached w/6ʺ o.c. beads I.S.O. Fix I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Insulation: 20 Concrete Drive or HD fasteners per 4' x 8' boards Optional: V-Force – Self Adhered or SBS Torch - Torched Cover Board: 4' x 4' boards attached w/6ʺ o.c. beads I.S.O. Fix I.S.O. Spray R I.S.O. Twin Pack I.S.O.Stick/Twin Jet Insulation: 32 Concrete Drive or HD fasteners per 4' x 8' board Optional: V-Force – Self Adhered or SBS Torch - Torched RoofNav Assembly Number UltraPly XR 100, 115 or 135 292145-0-0 6” o.c. ribbons: I.S.O. Spray R XR Stick UltraPly XR 100, 115 or 135 320536-0-0 6ʺ o.c. ribbons: I.S.O. Spray R XR Stick UltraPly XR 100, 115 or 135 320464-0-0 6ʺ o.c. ribbons: I.S.O. Spray R XR Stick UltraPly XR 100, 115 or 135 289296-0-0 4ʺ o.c. ribbons: I.S.O. Spray R XR Stick May 24 38 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, Adhered Cover Board Only, UltraPly XR membrane Uplift Deck Type Cover Board/ Insulation Cover Board/ Insulation Attachment Membrane and Attachment RoofNav Assembly Number 1-465 IF:NC EF: A Slope: 4ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Insulation: DensDeck, ¼ʺ min. or Securock, ¼ʺ min. Insulation: Full Coverage, Hot Asphalt, 4' x 4' boards UltraPly XR 100, 115 or 135 Full Coverage: XR Bonding Adhesive 243447-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete Deck, UltraPly XR membrane Uplift 1-720 IF:NC EF: A Slope: 4ʺ 1-945 IF:NC EF: A Slope: 2ʺ 1-975 IF:NC EF: A Slope: 1ʺ Deck Type Membrane Membrane Attachment RoofNav Assembly Number Concrete: Min. 2,500 psi Min. 2ʺ thick UltraPly TPO XR 115 or 135 Full Coverage: XR Bonding Adhesive 242966-0-0 Concrete: Min. 2,500 psi Min. 2ʺ thick UltraPly TPO XR 100, 115, or 135 Full Coverage: I.S.O. Spray 293219-0-0 Concrete: Min. 2,500 psi Min. 2ʺ thick UltraPly TPO XR 115 or 135 Full Coverage: Hot Asphalt 243438-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Concrete, Vapor Barrier, Adhesively Attached Insulation, UltraPly XR membrane Uplift Deck Type, Vapor Barrier 1-345 IF:NC EF: A Slope: ½ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Vapor Barrier (Required): MB Base, SBS Poly Base, SBS Premium Base SBS Smooth or Type IV or VI 1-345 IF:NC EF: A Slope: ½ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick Cover Board/ Insulation Cover Board/ Insulation Attachment Membrane and Attachment RoofNav Assembly Number Insulation: ISOGARD HD, ½ʺ thick, 4' x 4' boards Insulation: 4' x 4' boards 12ʺ o.c. beads Firestone I.S.O. Fix I.S.O. Spray I.S.O. Twin Pack I.S.O.Stick UltraPly TPO XR 100, 115, 135 Full Coverage: I.S.O. Spray XR Stick 292419-0-0 Insulation: 4' x 4' boards, 12ʺ o.c. beads Firestone I.S.O. Fix I.S.O. Spray I.S.O. Twin Pack I.S.O.Stick UltraPly TPO XR 100, 115, 135 Full Coverage: I.S.O. Spray XR Stick 292418-0-0 Insulation: DensDeck, ¼ʺ min. or Securock, ¼ʺ min. May 24 39 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings New Construction, Lightweight Insulated Concrete, UltraPly XR membrane Lightweight Manufacturer Uplift Deck Type 1-420 IF:NC EF: A Slope: ½ʺ Concrete: Min. 2,500 psi Min. 2ʺ thick 1-180 IF:NC EF: A Slope: ½ʺ Concrete: Min. 2,500 PSI Min. 2ʺ thick Range II Elastizell Lightweight Insulating Concrete 2ʺ min. thick. Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (min 340 psi) 2ʺ min. thick. Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO XR 100 or 115 membrane Full Coverage: XR Bonding Adhesive 244665-0244657 UltraPly TPO XR 100 or 115 membrane Full Coverage: XR Bonding Adhesive 244648-0244646 Firestone Fully Adhered Uplift Ratings Re-Cover Construction, Lightweight Insulating Concrete over Steel, Nailed Base Sheet with Adhesively Attached Insulation and Cover Board RoofNav Deck Insulation Membrane Uplift Cover Board / Insulation Membrane Assembly Type Attachment Attachment Number LWIC over Steel (Re-Cover) 1-90 IF:1 EF: A Slope: 2.5ʺ Base Sheet: Channel Venting Base MB Base SBS Base (Various) Insulation: 4' x 4' boards, 12” o.c. beads I.S.O. Fix II I.S.O. Twin Pack I.S.O.Stick Cover Board (4' x 4' boards): DensDeck, ¼ʺ min. or Securock, ¼ʺ min. Insulation (4' x 4' boards): ISOGARD GL, 1ʺ-8ʺ thick Tapered I.S.O., 1ʺ-8” thick (ISOGARD CG) .045 mil. min. UltraPly TPO UltraPly TPO SA Base Sheet: Two Piece Impact Nail, Seams – 35.4ʺ Rows, 7ʺ o.c. 2 Field Rows – 11.75ʺ o.c. staggered Single-Ply LVOC Single-Ply LVOC 1168 UltraPly Bonding WBBA P Self Adhered 327092-0-0 Firestone Fully Adhered Uplift Ratings New Construction, Lightweight Insulating Concrete over Structural Concrete, with Adhesively Attached Insulation and Cover Board Uplift 1-375 IF:NC EF: A Slope: 2.5ʺ Deck Type Celcore LWIC over Structural Concrete Min. 2,500 psi Min. 2ʺ thick Cover Board / Insulation Cover Board (4' x 4' boards): DensDeck, ¼ʺ min. or Securock, ¼ʺ min. Insulation (4' x 4' boards): ISOGARD GL, 1ʺ-12ʺ thick Tapered I.S.O., 1ʺ-8ʺ thick (ISOGARD CG) Insulation Attachment Membrane Insulation: 4' x 4' boards, 12ʺ o.c. beads I.S.O.Stick .045 mil. min. UltraPly TPO UltraPly TPO SA Membrane Attachment RoofNav Assembly Number Single-Ply LVOC Single-Ply LVOC 1168 UltraPly Bonding Self Adhered 339642-0339279 Firestone Fully Adhered Uplift Ratings Re-Cover Construction, Gypsum Deck, Adhesively Attached Insulation, Without Cover Board Uplift 1-90 IF:1 EF: A Slope: ¼ʺ Deck Type Insulation Insulation Attachment Membrane Membrane Attachment RoofNav Assembly Number Gypsum (Re-Cover) Insulation (4' x 4' boards): ISOGARD GL, 1ʺ-12ʺ thick Tapered I.S.O., 1ʺ-12ʺ thick ½ʺ ISOGARD HD Insulation: 4' x 4' boards, 12ʺ o.c. beads I.S.O. Twin Pack .045 mil. min. UltraPly TPO UltraPly TPO SA Single-Ply LVOC UltraPly Bonding Self Adhered 319860-0-0 May 24 40 | P a g e , 2018 t h Firestone Fully Adhered Uplift Ratings Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Cover Board Uplift Deck Type Cover Board / Insulation Gypsum (Re-Roof) (All layers 4' x 4' boards) Cover Board: DensDeck, ¼ʺ min., Securock, ¼ʺ min. Second Layer Insulation: ISOGARD GL, 1.5ʺ-8ʺ thick, Tapered I.S.O., 1.5ʺ-8ʺ thick Base Layer Insulation: ISOGARD GL, 1.5ʺ-4ʺ thick, Tapered I.S.O., 1.5ʺ-4ʺ thick Gypsum (Re-Roof) (All layers 4' x 4' boards) Insulation: ISOGARD GL, 1.5ʺ-12ʺ thick, or Tapered I.S.O., 1.5ʺ-12ʺ thick, 4' x 4' boards Gypsum (All layers 4' x 4' boards) Cover Board: DensDeck, ¼ʺ min., Securock, ¼ʺ min. Insulation: ISOGARD GL, 1.5ʺ-8ʺ thick, Tapered I.S.O., 1.5ʺ-8ʺ thick 1-90 IF: 1 EF: A Slope: 2.5ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: 2.5ʺ Insulation Attachment 12ʺ o.c. beads: Twin Pack Adhesive 12ʺ o.c. beads: Twin Pack Adhesive 12ʺ o.c. beads: I.S.O.Stick Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO membrane Water Basted UltraPly Single-Ply LVOC Single-Ply LVOC (1168) 113387-0-0 UltraPly TPO membrane Water Basted UltraPly Single-Ply LVOC Single-Ply LVOC (1168) 113389-0-0 UltraPly TPO membrane Water Basted UltraPly Single-Ply LVOC Single-Ply LVOC (1168) 115286-0-0 Membrane Attachment RoofNav Assembly Number Firestone Fully Adhered Uplift Ratings Re-Roof Construction, Gypsum Deck, Adhesively Attached Insulation, With Cover Board Uplift Deck Type Insulation Insulation Attachment Cover Board Cover Board Attachment Membrane 1-90 IF: 1 EF: A Slope: 2.5ʺ Gypsum (Re-Roof) None None 1-90 IF: 1 EF: A Slope: 2.5ʺ ISOGARD 12ʺ o.c. beads Gypsum GL, .5ʺ-12ʺ, of I.S.O.Stick (Re-Roof) 4' x 4' boards Adhesive ¼ʺ minimum, 4' x 4' boards: 12ʺ o.c. beads: DensDeck Twin Pack Securock UltraPly TPO membrane ¼ʺ minimum, 4' x 4' boards: 12ʺ o.c. beads: DensDeck I.S.O.Stick DensDeck Prime UltraPly TPO membrane UltraPly Water Based Bonding Adhesive P Single-Ply LVOC Single-Ply LVOC (1168) UltraPly Water Based Bonding Adhesive P Single-Ply LVOC Single-Ply LVOC (1168 May 24 113400-0-0 115286-0-0 41 | P a g e , 2018 t h Firestone Re-cover over Treated Wood Deck Adhered Membrane Uplift 1-75 IF: 1 EF: A Slope: ¼ʺ 1-75 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ 1-90 IF: 1 EF: A Slope: ¼ʺ Deck Type Insulation Cover Board Attachment Membrane Membrane Attachment RoofNav Assembly Number Treated Wood ISOGARD GL ½ʺ-1ʺ thick None 12 AP fasteners Plates per 4' x 8' boards UltraPly TPO membrane, Single weld UltraPly or SinglePly LVOC Bonding Adhesive 129268-0-0 Treated Wood ISOGARD GL ½ʺ-1ʺ thick None 12 AP fasteners Plates per 4' x 8' boards UltraPly TPO SA membrane, Single weld None 374222-0-0 Treated Wood ISOGARD GL Min. 1ʺ thick None 16 AP fasteners Plates per 4' x 8' boards UltraPly TPO membrane, Single weld UltraPly or SinglePly LVOC Bonding Adhesive 326804-0-0 Treated Wood ISOGARD GL ½ʺ-1ʺ thick None 16 AP fasteners Plates per 4' x 8' boards UltraPly TPO SA membrane, Single weld None 374236-0-0 Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane New Construction, Steel, Mechanically Attached Insulation, Single Weld Deck Type (Vapor Membrane Uplift Retarder/Thermal Insulation and Attachment Membrane Attachment Barrier) 1-60 IF: 1 EF: A Slope: ¾ʺ Steel 22-18-ga. 80 ksi 72ʺ span Steel: 20-16-ga., 33 ksi 72ʺ span 1-60 IF: 1 EF: A Slope: ¾ʺ 1-90 IF: 1 EF: A Slope: ¾ʺ 22-ga., 33 ksi 60ʺ span 22-ga., 80 ksi 72ʺ span Optional: V-Force or BASEGARD SA and DensDeck or Polyethylene Steel: 22-18-ga., 80 ksi 72ʺ span Optional: V-Force or BASEGARD SA and DensDeck or Polyethylene RoofNav Assembly Number Insulation: ISOGARD GL, 1.5ʺ-12ʺ Pre-securement – min. 5/board Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck UltraPly TPO membrane, 10' sheet 12ʺ o.c. HD fastener and HD or Barbed Seam Plate, Single weld 3080-0-0 Insulation: ISOGARD GL, 1.5ʺ-12ʺ Pre-securement – min. 5/board Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck UltraPly TPO membrane, 10' sheet 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 170476-0-0 ISOGARD GL, 1.5ʺ-12ʺ, Preliminary Securement or ISOGARD GL (Tapered) 1.5ʺ-4ʺ UltraPly TPO membrane, 10' sheet 12ʺ o.c. HD+ fastener and HD+ Seam Plate, Single weld 76911-0-0 May 24 42 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane New Construction, Steel, Mechanically Attached Insulation, Single Weld Deck Type (Vapor Membrane Uplift Retarder/Thermal Insulation and Attachment Membrane Attachment Barrier) Steel: 18-16-ga., 33 ksi 72ʺ span 1-90 IF: 1 EF: A Slope: ¾ʺ 1-90 IF: 1 EF: A Slope: ¾ʺ 1-105 IF: 1 EF: A Slope: ¾ʺ 1-105 IF: 1 EF: A Slope: ¾ʺ 1-105 IF: 1 EF: A Slope: 1ʺ 20-ga., 33 ksi 48ʺ span 20-ga., 80 ksi 72ʺ span 22-ga., 80 ksi 72ʺ span Steel: 20-16-ga., 33 ksi 72ʺ span 22-ga., 33 ksi 48ʺ span 22-ga., 80 ksi 72ʺ span Steel (WR): 18-ga., 33 ksi 54ʺ span 20-16-ga., 80 ksi 72ʺ span 22-ga., 80 ksi 60ʺ span Steel (WR): 20-18-ga., 33 ksi 72ʺ span 22-ga., 33 ksi 66ʺ span 22-ga., 80 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Insulation: ISOGARD GL, 1.5ʺ-12ʺ Pre-securement – min. 5/board Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ Pre-securement – min. 5/board Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ Pre-securement – min. 5/board Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ Pre-securement – min. 5/board Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation (Top): ISOGARD GL, 1.5ʺ-4ʺ, Preliminary Securement. Insulation (Bottom): ISOGARD GL, 1.5ʺ-8ʺ Optional: 4-6 mil. Polyethylene 1-105 IF: 1 EF: A Slope: 1ʺ Steel (WR): 22-18-ga. 33 ksi 72ʺ span Insulation (Top): ISOGARD GL, 1.5ʺ-4ʺ Preliminary Securement. Insulation (Bottom): ISOGARD GL, 1.5ʺ-8ʺ Optional: 4-6 mil. Polyethylene RoofNav Assembly Number UltraPly TPO 6ʺ o.c. HD fastener and membrane, HD or Barbed Seam Plate, 10' sheets Single weld 166431-0-0 UltraPly TPO membrane, 8' sheets 12ʺ o.c. HD+ fastener and HD+ Seam Plate, Single weld 213747-0-0 UltraPly TPO membrane, 10' sheets 6ʺ o.c. HD fastener and HD or Barbed Seam Plate, Single weld 3081-0-0 UltraPly TPO membrane, 6'-6ʺ sheets 6ʺ o.c. HD fastener and HD Plate, Single weld 3074-0-0 6ʺ o.c. HD+ fastener and HD+ Seam Plate, Single weld (The roof cover is secured UltraPly TPO with stress plates and membrane, 8' fasteners placed in the sheets side laps (spaced 90ʺ [2.9 m] o.c.) and an intermediate batten placed centered in the field of the roof cover.) 6ʺ o.c. HD+ fastener and HD+ Seam Plate, Single weld (The roof cover is secured UltraPly TPO with stress plates and 120 fasteners placed in the membrane, side laps (spaced 114ʺ 10' sheets [2.9 m] o.c.) and an intermediate batten placed centered in the field of the roof cover.) May 24 343455-0-0 343459-0-0 43 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings – Standard UltraPly membrane New Construction, Steel, Mechanically Attached Insulation, Single Weld Deck Type (Vapor Membrane Uplift Retarder/Thermal Insulation and Attachment Membrane Attachment Barrier) 1-105 IF: 1 EF: A Slope: 1ʺ Steel: 22-18-ga. 33 ksi, 72ʺ o.c. span Insulation (Top) Required: ISOGARD GL, 1.5ʺ-4ʺ Insulation (Bottom) Optional: ISOGARD GL, 1.5ʺ-8ʺ Optional: 4-6 mil. Polyethylene 114ʺ row spacing at 6ʺ o.c. spacing, HD Fasteners, UltraPly TPO Single Weld 10' sheets NOTE: Additional w/intermediate intermediate Batten attachment. Securement required at See note. 57ʺ o.c. row spacing at 6ʺ o.c. fasteners spacing. RoofNav Assembly Number 343409-0-0 Firestone Mechanically Attached Systems Uplift Ratings New Construction, Steel, Insulation with Cover Board, Single Weld Uplift 1-60 IF: 1 EF: A Slope: 5ʺ 1-60 IF: 1 EF: A Slope: 1ʺ 1-75 IF: 1 EF: A Slope: 5ʺ 1-75 IF: 1 EF: A Slope: 1.75ʺ Deck Type Steel: 20-16-ga., 33 ksi, 72ʺ o.c. span 22-ga., 33 ksi, 60ʺ o.c. span 22-ga., 80 ksi, 72ʺ o.c. span Steel: Insulation and Attachment Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Cover Board and Membrane Attachment Cover Board: ¼ʺ min., DensDeck DensDeck Prime Securock UltraPly TPO membrane, 10' sheet Membrane Attachment RoofNav Assembly Number 12ʺ o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 264245-0-0 Insulation: 20-16-ga., 33 ksi, ISOGARD GL, 1.5ʺ-12ʺ Cover Board: Attachment: 72ʺ o.c. span ½ʺ ISOGARD HD 114ʺ row spacing, 12ʺ Preliminary Securement ½ʺ Structodek HD UltraPly TPO o.c. 22-ga., 33 ksi, Optional: membrane, 10' HD fastener and HD 60ʺ o.c. span 4-6 mil. Polyethylene Attachment: sheet Seam Plate, or Preliminary Single weld V-Force (SA) or Securement 22-ga., 80 ksi, BASEGARD SA 72ʺ o.c. span over ¼ʺDensDeck Insulation: Cover Board: ISOGARD GL, 1.5ʺ-12ʺ ¼ʺ min. Steel: Attachment: DensDeck 114ʺ row spacing, 12ʺ 22-18-ga. Common Fastened DensDeck Prime UltraPly TPO o.c. 80 ksi, Securock membrane, 10' Optional: HD fastener and HD 72ʺ o.c. span sheets 4-6 mil. Polyethylene Seam Plate, Single weld Attachment: or Preliminary V-Force (SA) Securement over ¼ʺ DensDeck Insulation: Cover Board: ISOGARD GL, 1.5ʺ-12ʺ ½ʺ min. Attachment: Steel: Structodek HD UltraPly Common Fastened 12ʺ o.c. HD fastener and 22-18-ga., FiberTop B TPO HD Seam Plate, Single Optional: 80 ksi, membrane, weld 4-6 mil. Polyethylene 72ʺ o.c. span Attachment: 10' sheets or Preliminary V-Force (SA) Securement over ¼ʺ DensDeck 266089-0-0 381449-0-0 381629-0-0 11 May 24 44 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings New Construction, Steel, Insulation with Cover Board, Single Weld Uplift 1-75 IF: 1 EF: A Slope: 1ʺ Deck Type Steel: 22-18-ga., 80 ksi, 72ʺ o.c. span 1-75 IF: 1 EF: A Slope: 5ʺ Steel: 22-18-ga., 33 ksi, 72ʺ o.c. span 1-75 IF: 1 EF: A Slope: 1ʺ Steel: 22-18-ga., 33 ksi, 72ʺ o.c. span 1-90 IF: 1 EF: A Slope: 5ʺ 1-90 IF: 1 EF: A Slope: 1ʺ 1-105 IF: 1 EF: A Slope: 5ʺ Steel: 22-18-ga. 33 ksi, 72ʺ o.c. span Steel: 22-18-ga. 33 ksi, 72ʺ o.c. span Steel (WR): 22-18-ga. 33 ksi, 72ʺ o.c. span Insulation and Attachment Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Common Fastened Optional: 4-6 mil. Polyethylene or V-Force (SA) over ¼ʺ DensDeck Insulation: ISOGARD GL, 3ʺ-12ʺ Attachment: Preliminary Securement Optional: 4-6 mil. Polyethylene Insulation: ISOGARD GL, 3ʺ-12ʺ Attachment: Preliminary Securement Optional: 4-6 mil. Polyethylene Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: Optional Top Layer: ISOGARD GL, 1.5ʺ-4ʺ Required Bottom Layer: ISOGARD GL, 1.5ʺ-8ʺ Attachment: Preliminary Securement Optional: 4-6 mil. Polyethylene Cover Board and Attachment Membrane Membrane Attachment RoofNav Assembly Number Cover Board: ½ʺ min. Structodek HD FiberTop B Attachment: Preliminary Securement UltraPly TPO membrane, 10' sheets 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 381672-0-0 UltraPly TPO membrane, 8' sheets 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 339004-0-0 UltraPly TPO membrane, 8' sheets 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 338538-0-0 UltraPly TPO membrane, 6'-6ʺ sheets 6ʺ o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 339174-0-0 UltraPly TPO membrane, 6'-6ʺ sheet 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 339172-0-0 UltraPly TPO membrane, 10' sheets 6ʺ o.c. HD fastener and HD Seam Plate, Single weld (UltraPly TPO MF - Lap Securement 114" OC-6" – w/Intermediate Batten Securement (57" OC - 6") 343411-0-0 Cover Board: ¼ʺ min. DensDeck Securock Attachment: Preliminary Securement Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement Cover Board: ¼ʺ min. DensDeck Securock Attachment: Preliminary Securement Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement Cover Board: ¼ʺ min. DensDeck Securock Attachment: Preliminary Securement May 24 45 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings New Construction, Steel, Insulation with Cover Board, Single Weld Uplift 1-105 IF: 1 EF: A Slope: 1ʺ Deck Type Insulation and Attachment Cover Board and Attachment Steel (WR): 22-18-ga. 33 ksi, 72ʺ o.c. span Insulation: Optional Top Layer: ISOGARD GL, 1.5ʺ-4ʺ Required Bottom Layer: ISOGARD GL, 1.5ʺ-8ʺ Attachment: Preliminary Securement Optional: 4-6 mil. Polyethylene Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO membrane,10' sheets 6ʺ o.c. HD fastener and HD Seam Plate, Single weld (The roof cover is secured with stress plates and fasteners placed in the side laps spaced 114ʺ [2.9 m] o.c. w/intermediate batten placed centered in the field of the roof cover. 343408-0-0 Firestone Mechanically Attached Systems Uplift Ratings New Construction, Concrete, Insulation with Cover Board, Single Weld Uplift Deck Type 1-60 IF: NC EF: A Slope: 5ʺ Concrete: 2,500 psi Min. 2ʺ thick 1-60 IF: NC EF: A Slope: 1ʺ Concrete: 2,500 psi Min. 2ʺ thick 1-75 IF: NC EF: A Slope: 5ʺ Concrete: 2,500 psi Min. 2ʺ thick 1-75 IF: NC EF: A Slope: 1ʺ Concrete: 2,500 psi Min. 2ʺ thick Insulation and Attachment Cover Board and Attachment Membrane Membrane Attachment RoofNav Assembly Number Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Insulation: ISOGARD GL, 1.5ʺ-12ʺ Attachment: Preliminary Securement Cover Board: ¼ʺ min. DensDeck Securock Attachment: Preliminary Securement UltraPly TPO membrane, 10' sheet 12ʺ o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 269751-0-0 Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement UltraPly TPO membrane, 10' sheet 12ʺ o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 269750-0-0 Cover Board: ¼ʺ min. DensDeck Securock Attachment: Preliminary Securement UltraPly TPO membrane, 10' sheet 6ʺ o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 269742-0-0 Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement UltraPly TPO membrane, 10' sheet 6ʺ o.c. HD fastener and HD Seam Plate or UltraPly TPO Barbed Seam Plate, Single weld 269741-0-0 Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO membrane, 10' sheet 12ʺ o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 305074-0-0 Firestone Mechanically Attached Systems Uplift Ratings Recover, Metal Building, Insulation with Cover Board Insulation Cover Board Uplift Deck Type Flute Filler and and Attachment Attachment 1-60 IF: 1 EF: A Slope: 1ʺ Standing/ Lap Seam Roof (Insulated) ISOGARD GL, 1ʺ min. ISOGARD GL .5ʺ-1ʺ thick Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement May 24 46 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings Recover, Metal Building, Insulation with Cover Board Insulation Flute Cover Board and Uplift Deck Type and Filler Attachment Attachment 1-60 IF: 1 EF: A Slope: 5ʺ Standing/ Lap Seam Roof (Insulated) 1-60 IF: 1 EF: A Slope: 1ʺ Standing/ Lap Seam Roof (Insulated) 1-60 IF: 1 EF: A Slope: 5ʺ Standing/ Lap Seam Roof (Insulated) 1-90 IF: 1 EF: A Slope: 1ʺ 1-105 IF: 1 EF: A Slope: 1ʺ ISOGARD GL, 1ʺ min. ISOGARD GL, 1ʺ min. ISOGARD GL, 1ʺ min. ISOGARD GL .5ʺ-1ʺ thick ISOGARD GL .5ʺ-1ʺ thick ISOGARD GL .5ʺ-1ʺ thick Standing/ Lap Seam Roof (Insulated) ISOGARD GL, 1ʺ min. ISOGARD GL .5ʺ-1ʺ thick Standing/ Lap Seam Roof (Insulated) ISOGARD GL, 1ʺ min. ISOGARD GL 1ʺ-12ʺ thick 1-105 Standing/ IF: 1 Lap Seam ISOGARD EF: A Roof GL 1ʺ min. Slope: (Uninsulated) 1ʺ 1-105 IF: 1 EF: A Slope: 1ʺ Standing/ Lap Seam Roof (Insulated) ISOGARD GL 1ʺ min. 1-105 IF: 1 EF: A Slope: 5ʺ Standing/ Lap Seam Roof (Insulated) 1-105 Standing/ IF: 1 Lap Seam EF: A Roof Slope: (Uninsulated) 5ʺ ISOGARD GL 1ʺ-12ʺ thick Cover Board: ¼ʺ min. DensDeck Securock Attachment: Preliminary Securement Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement Cover Board: ¼ʺ min. DensDeck DensDeck Prime Securock Attachment: Preliminary Securement Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Securement Cover Board: ¼ʺ min. DensDeck DensDeck Prime Securock Attachment: Preliminary Attachment Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO membrane, 10' sheet 12” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 305080-0-0 UltraPly TPO membrane, 6'-6ʺ sheet 12ʺ o.c. with Firestone Purlin Fasteners and Metal Batten Strip, Wide Weld 305058-0-0 UltraPly TPO membrane, 6'-6ʺ sheet 12” o.c. with Firestone Purlin Fasteners and Metal Batten Strip, Wide Weld 305060-0-0 UltraPly TPO membrane, 8' sheet UltraPly TPO membrane, 12'-4ʺ sheet UltraPly TPO membrane, ISOGARD GL .5ʺ-1ʺ thick Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment: Preliminary Attachment UltraPly TPO membrane ISOGARD GL, 1ʺ min. ISOGARD GL .5ʺ-1ʺ thick DensDeck, DensDeck Prime or Securock, ¼ʺ min. Preliminary Attachment UltraPly TPO membrane None DensDeck or Securock ¼ʺ min. DensDeck, DensDeck Prime or Securock ¼” min. Preliminary Attachment UltraPly TPO membrane 12ʺ o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 6” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 6ʺ o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 142ʺ Row Spacing, 6ʺ o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 142ʺ Row Spacing, 6” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 142ʺ Row Spacing, 6” o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld May 24 305221-0-0 265291-0-0 265296-0-0 305233-0-0 305237-0-0 283990-0-0 47 | P a g e , 2018 t h Firestone Mechanically Attached Systems Uplift Ratings Recover, Metal Building, Insulation without Cover Board Uplift Deck Type 1-60 IF: 1 EF: A Slope: 1ʺ 1-90 IF: 1 EF: A Slope: 1ʺ Flute Filler Standing/ Lap Seam Roof (Insulated) ISOGARD GL, 1ʺ, loose laid Standing/ Lap Seam Roof (Insulated) ISOGARD GL, 1ʺ, loose laid Insulation and Attachment ISOGARD GL, .5ʺ-1ʺ thick, presecurement, minimum 5 fasteners per 4' x 8' board ISOGARD GL, .5ʺ-1ʺ thick, presecurement, minimum 5 fasteners per 4' x 8' board Membrane UltraPly TPO membrane UltraPly TPO membrane Membrane Attachment 114ʺ Row Spacing, 12ʺ o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld 90ʺ Row Spacing, 12ʺ o.c. with Firestone Purlin Fasteners and HD Seam Plates, Single Weld RoofNav Assembly Number 305068-0-0 305219-0-0 Firestone Mechanically Attached Systems – Invisiweld System Uplift Ratings Recover, Metal Building, Flute Filler with Cover Board Uplift Deck Type 1-60 IF: 1 EF: A Slope: 1ʺ Standing/ Lap Seam Roof (Insulated) Flute Filler Cover Board and Attachment ISOGARD GL ½ʺ ISOGARD HD ½ʺ Structodek HD Preliminary Attachment Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO membrane 60ʺ Row Spacing, 12ʺ o.c. with Firestone Purlin Fasteners and Invisiweld Plates, Single Weld 273139-0-0 Firestone Mechanically Attached Systems Uplift Ratings – UltraPly XR 100 and XR 115 Recover, Steel Deck, UltraPly TPO XR membrane, Single Weld Uplift 1-60 IF: 1 EF: A Slope: ½ʺ 1-90 IF: 1 EF: A Slope: ½ʺ 1-90 IF: 1 EF: A Slope: ½ʺ 1-135 IF: 1 EF: A Slope: ½ʺ Deck Type Membrane Membrane Attachment RoofNav Assembly Number Steel: any thickness/class, Recover UltraPly TPO XR 100, 115, 135 membrane, 10' sheet 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 242937-0-0 Steel: 80 ksi Recover UltraPly TPO XR 100, 115, 135 membrane, 10' sheet 12ʺ o.c. HD+ fastener and HD+ Seam Plate, Single weld 242946-0-0 Steel: any thickness/class, Recover UltraPly TPO XR 100, 115, 135 membrane, 10' sheet 6ʺ o.c. HD fastener and HD+ Seam Plate, Single weld 242950-0-0 Steel: any thickness/class, Recover UltraPly TPO XR 100, 115, 135 membrane, 10' sheet 6ʺ o.c. HD+ fastener and HD+ Seam Plate, Single weld 242951-0-0 Firestone Mechanically Attached Systems Uplift Ratings Recover, Concrete Deck, UltraPly TPO XR membrane, Single Weld Uplift 1-60 IF: NC EF: A Slope: ½ʺ 1-90 IF: NC EF: A Slope: ½ʺ Deck Type Membrane Membrane Attachment RoofNav Assembly Number Concrete: Recover UltraPly TPO XR 100, 115, 135 membrane, 10' sheet 12ʺ o.c. HD fastener and HD Seam Plate, Single weld 242935-0-0 Concrete: Recover UltraPly TPO XR 100, 115, 135 membrane, 10' sheet 6ʺ o.c. HD fastener and HD Seam Plate, Single weld 242949-0-0 May 24 48 | P a g e , 2018 t h Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Invisiweld System, Induction Welded Uplift Deck Type 1-90 IF: 1 EF: A Slope: ¾ʺ Steel: 22-16-ga. 33 ksi 72ʺ span 1-90 IF: 1 EF: A Slope: ¾ʺ Steel: 22-16-ga. 33 ksi, 72ʺ span Insulation and Attachment Insulation: ISOGARD GL 1.5ʺ-12ʺ thick Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: ISOGARD GL 1.5ʺ-12ʺ thick 4' x 8' boards Thermal Barrier: DensDeck ¼ʺ thick 4' x 8' boards Cover Board Attachment Membrane Membrane Attachment RoofNav Assembly Number None 6 HD fasteners and Invisiweld Plates per 4' x 8' boards UltraPly TPO membrane, Single weld Invisiweld System 250651-0-0 None 6 HD fasteners and Invisiweld Plates per 4' x 8' boards UltraPly TPO membrane, Single weld Invisiweld System 399280-0-0 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Invisiweld System, Induction Welded Uplift 1-90 IF: 1 EF: A Slope: 1ʺ 1-90 IF: 1 EF: A Slope: 5ʺ Deck Type Steel: 22-16-ga. 33 ksi 72ʺ span Steel: 22-16-ga. 33 ksi 72ʺ span Insulation and Attachment Insulation: ISOGARD GL 1.5ʺ-12ʺ thick Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: ISOGARD GL 1.5ʺ-12ʺ thick Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck 1-90 IF: NC EF: A Slope: ¾ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: ISOGARD GL 1.5ʺ-12ʺ thick 1-90 IF: NC EF: A Slope: 1ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: ISOGARD GL 1.5ʺ-12ʺ thick Cover Board Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Cover Board: ¼ʺ min. DensDeck Securock None Cover Board: ½ʺ ISOGARD HD ½ʺ Structodek HD Attachment Membrane Membrane Attachment RoofNav Assembly Number 6 HD fasteners and Invisiweld Plates per 4' x 8' boards UltraPly TPO membrane, Single weld Invisiweld System 277978-0-0 6 HD fasteners and Invisiweld Plates per 4' x 8' boards UltraPly TPO membrane, Single weld Invisiweld System 277977-0-0 UltraPly TPO membrane, Single weld Invisiweld System 250819-0-0 UltraPly TPO membrane, Single weld Invisiweld System 251817-0-0 6 HD or Concrete Drive fasteners and Invisiweld Plates per 4' x 8' boards 6 HD or Concrete Drive fasteners and Invisiweld Plates per 4' x 8' boards May 24 49 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Invisiweld System, Induction Welded Uplift 1-90 IF: NC EF: A Slope: 5ʺ 1-120 IF: 1 EF: A Slope: ¾ʺ 1-120 IF: 1 EF: A Slope: 1ʺ 1-120 IF: 1 EF: A Slope: 5ʺ Deck Type Concrete: 2500 psi Min. 2ʺ thick Steel: 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span 1-120 IF: NC EF: A Slope: ¾ʺ Concrete: 2500 psi Min. 2ʺ thick 1-120 IF: NC EF: A Slope: 1ʺ Concrete: 2500 psi Min. 2ʺ thick 1-120 IF: NC EF: A Slope: 5ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation and Attachment Insulation: ISOGARD GL 1.5ʺ-12ʺ thick Attachment Membrane Membrane Attachment RoofNav Assembly Number 6 HD or Concrete Cover Board: Drive ¼ʺ DensDeck fasteners and ¼ʺ DensDeck Prime Invisiweld ¼ʺ Securock Plates per 4' x 8' board UltraPly TPO membrane, Single weld Invisiweld System 251833-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254071-0-0 UltraPly TPO membrane, Single weld Invisiweld System 278052-0-0 UltraPly TPO membrane, Single weld Invisiweld System 278051-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254075-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254076-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254078-0-0 Cover Board Insulation: 4' x 8' boards ISOGARD GL 24ʺ rows 1.5ʺ-12ʺ thick spacing 24ʺ on center Optional: None Invisiweld 4-6 mil. Polyethylene Plates and or HD Fasteners V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: 4' x 8' boards 24ʺ rows ISOGARD GL Cover Board: spacing 1.5ʺ-12ʺ thick 4' x 8' boards 24ʺ on center Optional: ½ʺ ISOGARD HD Invisiweld 4-6 mil. Polyethylene ½ʺ Structodek HD Plates and or V-Force (SA) or HD Fasteners BASEGARD SA over ¼ʺ DensDeck Insulation: 4' x 8' boards 24ʺ rows ISOGARD GL Cover Board: spacing 1.5ʺ-12ʺ thick 4' x 8' boards 24ʺ on center Optional: ¼ʺ DensDeck Invisiweld 4-6 mil. Polyethylene ¼ʺ DensDeck Prime Plates and or V-Force (SA) or ¼ʺ Securock HD Fasteners BASEGARD SA over ¼” DensDeck 8 HD or Insulation: Concrete 4' x 8' boards Drive ISOGARD GL None fasteners and 1.5ʺ-12ʺ thick Invisiweld Plates per 4' x 8' board 8 HD or Insulation: Cover Board: Concrete Drive 4' x 8' boards ½ʺ ISOGARD HD fasteners ISOGARD GL ½ʺ Structodek HD and Invisiweld 1.5ʺ-12ʺ thick Plates per 4' x 8' board 8 HD or Insulation: Cover Board: Concrete 4' x 8' boards 4' x 8' boards Drive ISOGARD GL ¼ʺ DensDeck fasteners and 1.5ʺ-12ʺ thick ¼ʺ DensDeck Prime Invisiweld ¼ʺ Securock Plates per 4' x 8' board May 24 50 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Invisiweld System, Induction Welded Uplift 1-150 IF: 1 EF: A Slope: ¾ʺ 1-150 IF: 1 EF: A Slope: 1ʺ 1-150 IF: 1 EF: A Slope: 5ʺ Deck Type Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Steel (WR): 22-18-ga. 33 ksi 72ʺ span Insulation and Attachment Cover Board Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick Optional: None 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: 4' x 8' boards ISOGARD GL Cover Board: 1.5ʺ-12ʺ thick 4' x 8' boards Optional: ½ʺ ISOGARD HD 4-6 mil. Polyethylene ½ʺ Structodek HD or V-Force (SA) or BASEGARD SA over ¼” DensDeck Insulation: 4' x 8' boards ISOGARD GL Cover Board: 1.5ʺ-12ʺ thick 4' x 8' boards Optional: ¼ʺ DensDeck 4-6 mil. Polyethylene ¼ʺ DensDeck Prime or ¼ʺ Securock V-Force (SA) or BASEGARD SA over ¼” DensDeck 1-150 IF: NC EF: A Slope: ¾ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick 1-150 IF: NC EF: A Slope: 1ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick 1-150 IF: NC EF: A Slope: 5ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick Attachment Membrane Membrane Attachment RoofNav Assembl y Number 12 HD fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO membrane, Single weld Invisiweld System 253954-0-0 12 HD fasteners and Invisiweld Plates per 4’x8’ board UltraPly TPO membrane, Single weld Invisiweld System 254053-0-0 12 HD fasteners and Invisiweld Plates per 4' x 8' board UltraPly TPO membrane, Single weld Invisiweld System 254055-0-0 Invisiweld System 254056-0-0 Invisiweld System 254057-0-0 Invisiweld System 254059-0-0 12 HD or Concrete Drive UltraPly TPO None fasteners and membrane, Invisiweld Single weld Plates per 4' x 8' board 12 HD Cover Board: Concrete 4' x 8' boards Drive UltraPly TPO ½ʺ ISOGARD HD fasteners and membrane, ½ʺ Structodek HD Invisiweld Single weld Plates per 4' x 8' board Cover Board: 12 HD Concrete 4' x 8' boards Drive fasteners UltraPly TPO ¼ʺ DensDeck and Invisiweld membrane, ¼ʺ DensDeck Prime Plates per Single weld ¼ʺ Securock 4' x 8' board May 24 51 | P a g e , 2018 t h Continued Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Invisiweld System, Induction Welded Uplift 1-210 IF: 1 EF: A Slope: ¾ʺ 1-210 IF: 1 EF: A Slope: 1ʺ 1-210 IF: 1 EF: A Slope: 5ʺ Deck Type Steel (WR): 20-18-ga. 33 ksi, 72ʺ span 22-ga. 33 ksi 64ʺ span 22-18-ga. 80 ksi 72ʺ span Steel (WR): 20-18-ga. 33 ksi 72ʺ span 22-ga. 33 ksi 64ʺ span 22-18-ga. 80 ksi 72ʺ span Steel (WR): 20-18-ga. 33 ksi 72ʺ span 22-ga. 33 ksi 64ʺ span 22-18-ga. 80 ksi 72ʺ span Insulation and Attachment Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick Optional: 4-6 mil. Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Cover Board Cover Board: 4' x 8' boards ½ʺ ISOGARD HD ½ʺ Structodek HD Insulation: 4' x 8' boards ISOGARD GL Cover Board: 1.5ʺ-12ʺ thick 4' x 8' boards Optional: ½ʺ ISOGARD HD 4-6 mil. ½ʺ-1ʺ Structodek HD Polyethylene or V-Force (SA) or BASEGARD SA over ¼ʺ DensDeck Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick Cover Board: Optional: 4' x 8' boards 4-6 mil. ¼ʺ DensDeck Polyethylene or ¼ʺ Securock V-Force (SA) or BASEGARD SA over ¼” DensDeck 1-210 IF: NC EF: A Slope: ¾ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick 1-210 IF: NC EF: A Slope: 1ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick 1-210 IF: NC EF: A Slope: 5ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards ISOGARD GL 1.5ʺ-12ʺ thick Attachment Membrane Membrane Attachment RoofNav Assembly Number 24ʺ rows spacing 12ʺ on center Invisiweld Plates and HD Fasteners UltraPly TPO membrane, Single weld Invisiweld System 254090-0-0 24ʺ rows spacing 12ʺ on center Invisiweld Plates and HD Fasteners UltraPly TPO membrane, Single weld Invisiweld System 278067-0-0 24ʺ rows spacing 12ʺ on center Invisiweld Plates and HD Fasteners UltraPly TPO membrane, Single weld Invisiweld System 278066-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254112-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254115-0-0 UltraPly TPO membrane, Single weld Invisiweld System 254119-0-0 16 HD or Concrete Drive None fasteners and Invisiweld Plates per 4' x 8' board 16 HD Concrete Cover Board: Drive 4' x 8' boards fasteners and ISOGARD HD ½ʺ or Invisiweld Structodek HD ½ʺ-1ʺ Plates per 4' x 8' board 16 HD Cover Board: Concrete 4' x 8' boards Drive ¼ʺ DensDeck fasteners and ¼ʺ DensDeck Prime Invisiweld ¼ʺ Securock Plates per 4' x 8' board May 24 52 | P a g e , 2018 t h Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld System Recover, Metal Building, Invisiweld System, Induction Welded Deck Type Uplift 1-90 IF: 1 EF: A Slope: 1ʺ 1-105 IF: 1 EF: A Slope: ¾ʺ 1-105 IF: 1 EF: A Slope: ¾ʺ 1-105 IF: 1 EF: A Slope: 1¾ʺ 1-105 IF: 1 EF: A Slope: 5ʺ Flute Filler Insulation Steel: Standing Seam Insulated ISOGARD GL, ½ʺ thick ISOGARD GL, ½ʺ thick, 5 HD fasteners and Insulation Plates per 4' x 8' board Steel: Standing Seam ISOGARD GL, 1.5ʺ-8ʺ thick ISOGARD GL, 1.5ʺ-4ʺ thick, 5 HD fasteners and Insulation Plates per 4' x 8' board Steel: Standing Seam ISOGARD GL, 1ʺ-4ʺ thick ISOGARD HD, ½ʺ or Structodek HD ½ʺ-1ʺ thick Preliminary Attachment Steel: Standing Seam ISOGARD GL, 1ʺ-4ʺ thick OSB, ⅜ʺ– ½ʺ thick, 5 HD fasteners and Insulation Plates per 4' x 8' board ISOGARD GL, 1ʺ-12ʺ thick DensDeck/DensDeck Prime, or Securock, ¼ʺ min., 5 HD fasteners and Insulation Plates per 4' x 8' board Steel: Standing Seam Attachment 12ʺ on center Purlin fastener and Invisiweld Plate, 60” row spacing 6ʺ on center Purlin fastener and Invisiweld Plate, 120ʺ row spacing 6ʺ on center Purlin fastener and Invisiweld Plate, 120ʺ row spacing 6ʺ on center Purlin fastener and Invisiweld Plate, 120ʺ row spacing 6ʺ on center Purlin fastener and Invisiweld Plate, 120ʺ row spacing Membrane Membrane Attachment RoofNav Assembly Number UltraPly TPO membrane, Single weld Induction Welded 273140-0-0 UltraPly TPO membrane, Single weld Induction Welded 253893-0-0 UltraPly TPO membrane, Single weld Induction Welded 253890-0-0 UltraPly TPO membrane, Single weld Induction Welded 253897-0-0 UltraPly TPO membrane, Single weld Induction Welded 253900-0-0 Firestone Mechanically Attached Systems Uplift Ratings – Invisiweld- S System Invisiweld-S System, Induction Welded Uplift Deck Type Insulation Cover Board Attachment Membrane Membrane Attachment RoofNav Assembly Number 1-150 IF: NC EF: A Slope: ¾ʺ Concrete: 2500 psi Min. 2ʺ thick Insulation: 4' x 8' boards, ISOGARD GL 1.5ʺ-12ʺ thick None 10 HD or Concrete Drive fasteners and Invisiweld-S Plates per 4' x 8' board UltraPly TPO membrane, Single weld Invisiweld-S System 382976-0-0 Required: Steel Deck (WR): ISOGARD GL 1.5ʺ-12ʺ 22-18 ga. thick 33 ksi. Optional: 72ʺ span 4-6 mil. Poly or V-Force SA over DensDeck None 10 HD fasteners and UltraPly TPO Invisiweld-S Plates membrane, per 4' x 8' board Single Weld Invisiweld-S System 382977-0-0 1-150 Firestone Re-cover over Treated Wood Deck InvisiWeld Attached Membrane Uplift 1-90 IF: 1 EF: A Slope: ¾ʺ 1-90 IF: 1 EF: A Slope: 1ʺ Deck Type Insulation Treated ISOGARD GL Wood ½ʺ-1ʺ thick (Re-cover) Treated Wood ISOGARD GL ½ʺ min. thick Cover Board Attachment Membrane Membrane Attachment RoofNav Assembly Number None 6 AP fasteners and Invisiweld Plates per 4' x 8' board .045 mil. min. UltraPly TPO InvisiWeld System 250823-0-0 ½ʺ ISOGARD HD or Structodek HD Fiberboard 6 AP fasteners and Invisiweld Plates per 4' x 8' board .045 mil. min. UltraPly TPO InvisiWeld System 251855-0-0 May 24 53 | P a g e , 2018 t h Factory Mutual Ballast Guidelines Stone Ballast ASTM D448 — Standard Size No. 3 for Coarse Aggregate (nominal 1-2ʺ [25 to 50 mm] diameter). This standard permits amounts (by weight percent) to pass through the square sieve openings as shown in Table 6. Table 6. Gradation for No. 3 Stone Size Number Nominal Size in. (mm) 3 1 to 2 (25 - 50) Sieve Opening in. (mm) 2½ (63) 2 (50) 1½ (38) 1 (25) ¾ (19) ½ (13) 100 90 to 100 35 to 70 0 to 15 -- 0 to 5 Aggregate Surfacing for BUR ASTM D1863 — Mineral Aggregate Used on Built-Up Roofs gives gradation and moisture content for aggregate surfacing as noted in Table 7. Table 7. Gradation for Gravel for BURs Sieve Amounts finer than sieve specified (mass %) Size 6 Size 67 Size 7 25 mm 100 100 --- 19 mm 90 to 100 90 to 100 100 12.5 mm 20 to 55 --- 90 to 100 9.5 mm 0 to 15 20 to 55 40 to 70 4.75 mm 0 to 5 0 to 10 0 to 15 2.36 mm --- 0 to 5 0 to 5 The moisture content limit for stone is £2 percent and £5 percent for slag. The dust content limit for stone and slag is greater than or equal to 2 percent. May 24 54 | P a g e , 2018 t h
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 54 Language : en-US Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Microsoft® Word 2016 Creator : Jenny Sherwin Creator Tool : Microsoft® Word 2016 Create Date : 2018:05:24 08:37:26-05:00 Modify Date : 2018:05:24 08:37:26-05:00 Document ID : uuid:A617B7DA-49D8-49C9-B130-EEC8E30F0ABA Instance ID : uuid:A617B7DA-49D8-49C9-B130-EEC8E30F0ABA Part : 3 Conformance : A Author : Jenny SherwinEXIF Metadata provided by EXIF.tools