PROFINET With STEP 7 V15 Step7 Function Manual En US
User Manual:
Open the PDF directly: View PDF .
Page Count: 277
Download | |
Open PDF In Browser | View PDF |
___________________ Preface 1 ___________________ Documentation guide SIMATIC PROFINET PROFINET with STEP 7 V15 Function Manual 12/2017 A5E03444486-AH 2 ___________________ Description Parameter 3 ___________________ assignment/addressing Diagnostics and 4 ___________________ maintenance 5 ___________________ Functions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY A5E03444486-AH Ⓟ 12/2017 Subject to change Copyright © Siemens AG 2013 - 2017. All rights reserved Preface Purpose of the documentation This function manual provides an overview of the PROFINET communication system with SIMATIC STEP 7 V15. STEP 7 V15 is integrated into the high-performance graphical Totally Integrated Automation Portal (TIA Portal), the new integration platform for all automation software tools. This function manual supports you in planning a PROFINET system. The manual is structured into the following subject areas: ● PROFINET basics ● PROFINET diagnostics ● PROFINET functions Basic knowledge required The following knowledge is required in order to understand the manual: ● General knowledge of automation technology ● Knowledge of the industrial automation system SIMATIC ● Knowledge about the use of Windows-based computers ● Knowledge about how to use STEP 7 (TIA Portal) Scope This documentation is the basic documentation for all SIMATIC products from the PROFINET environment. The product documentation is based on this documentation. The examples are based on the functionality of the S7-1500 automation system. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 3 Preface What's new in the PROFINET function manual, version 12/2017 compared to version 09/2016 This manual (version 12/2017) encompasses the following new functions compared to the previous version (version 09/2016): Function Applications Your benefits Specifying the router for a PROFINET IO device You can specify the IP address of a router for each IO device. You reach the IO device from outside the IP subnet through the router. In the past, it was only possible to specify a router for a PROFINET IO interface at the IO controller. The IO devices inherited the setting of the IO controller interface. Now you can set the router address independently of the IO controller setting. This allows, for example, a router address at the IO device although you have not set a router address or have set a different address at the IO controller. Configuring an IO device through hardware detection You can detect an existing IO device and enter STEP 7 inserts the IO device with all the modules and submodules into the project. Article numbers it in your project. and firmware versions between real and configured IO devices match. Asset management You can centrally manage non-PROFINET components (assets) of a PROFINET device. The PROFINET device makes the identification data of the assets available for evaluation via a standardized data record. You reduce the project planning work required. Asset manageSpecial application of asset management: ment data record for I- From the point of view of a higher-level IO devices controller, the modules plugged into the Idevice represent assets. The user program in the I-device compiles the asset management data record. The IO controller can read identification data of the I-device modules through this data record. The new standardized PROFINET service makes it possible to manage all the hardware and firmware components of PROFINET devices centrally. The possibilities available for filtering device data, for example, depend on the range of performance of the evaluating application. See Asset management. PROFINET with STEP 7 V15 4 Function Manual, 12/2017, A5E03444486-AH Preface What's new in the PROFINET function manual, Version 09/2016 compared to Version 12/2014 This manual (version 09/2016) encompasses the following new functions compared to the previous version (version 12/2014): Function Applications User benefits PROFINET IO on the 2nd PROFINET interface You can operate another PROFINET IO system on the CPU or connect additional IO devices. You use a fieldbus type in the plant. The CPU can perform fast and deterministic data exchange as an I-device with a higher-level controller (PROFINET/Ethernet) through the second line. IRT with very short You realize high-end applications with IO data cycle times down communication which place very high perforto 125 µs mance demands on the IO processing. You make PROFINET IO communication and standard communication possible via one cable even with a send clock of 125 µs. MRPD: Media Redundancy with Planned Duplication of frames PROFINET IO IRT enables you to realize applications that place particularly high demands on the reliability and accuracy (isochronous mode). By sending the cyclic IO data in both directions in the ring, the communication to the IO devices is maintained even when the ring is interrupted and does not result in device failure even with fast update times. You achieve higher reliability than with MRP. PROFINET performance upgrade You can implement applications with high speed and send clock requirements. This is interesting for applications with high demands on performance. Better utilization of the bandwidth results in short reaction times. Limitation of the data infeed into the network You limit the network load for standard Ethernet communication to a maximum value. You flatten peaks in the data feed. You share the remaining bandwidth based on demand. Conventions STEP 7: We refer to "STEP 7" in this documentation as a synonym for the configuration and programming software "STEP 7 as of V12 (TIA Portal)" and subsequent versions. This documentation contains pictures of the devices described. The figures may differ slightly from the device supplied. You should also pay particular attention to notes such as the one shown below: Note A note contains important information on the product, on handling of the product and on the section of the documentation to which you should pay particular attention. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 5 Preface Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens' products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial security measures that may be implemented, please visit (http://www.siemens.com/industrialsecurity). Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under (http://www.siemens.com/industrialsecurity). Siemens Industry Online Support You can find current information on the following topics quickly and easily here: ● Product support All the information and extensive know-how on your product, technical specifications, FAQs, certificates, downloads, and manuals. ● Application examples Tools and examples to solve your automation tasks – as well as function blocks, performance information and videos. ● Services Information about Industry Services, Field Services, Technical Support, spare parts and training offers. ● Forums For answers and solutions concerning automation technology. ● mySupport Your personal working area in Industry Online Support for messages, support queries, and configurable documents. This information is provided by the Siemens Industry Online Support in the Internet (http://www.siemens.com/automation/service&support). PROFINET with STEP 7 V15 6 Function Manual, 12/2017, A5E03444486-AH Preface Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP). You can find catalogs for all automation and drive products on the Internet (https://mall.industry.siemens.com). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 7 Table of contents Preface ................................................................................................................................................... 3 1 Documentation guide ............................................................................................................................ 12 2 Description............................................................................................................................................ 17 3 2.1 2.1.1 2.1.2 2.1.3 2.1.4 Introduction to PROFINET ..................................................................................................... 17 PROFINET terms ................................................................................................................... 19 Basic terminology of communication ..................................................................................... 22 PROFINET interface .............................................................................................................. 25 Implementation of the PROFINET device model in SIMATIC ............................................... 28 2.2 2.2.1 2.2.2 2.2.3 2.2.3.1 2.2.3.2 2.2.4 2.2.4.1 2.2.4.2 2.2.4.3 Setting up PROFINET ............................................................................................................ 30 Active Network Components.................................................................................................. 31 Cabling technology ................................................................................................................ 33 Wireless design ...................................................................................................................... 35 Basics ..................................................................................................................................... 35 Tips on assembly ................................................................................................................... 37 Network security..................................................................................................................... 38 Basics ..................................................................................................................................... 38 Network components and software........................................................................................ 40 Application example ............................................................................................................... 41 Parameter assignment/addressing ........................................................................................................ 43 3.1 Assigning an IO device to an IO controller ............................................................................ 45 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 Device name and IP address ................................................................................................. 47 Device name .......................................................................................................................... 48 IP address .............................................................................................................................. 49 Assigning a device name and IP address .............................................................................. 52 Assign device name via communication table ....................................................................... 57 Permitting changes to the device name and IP address directly on the device .................... 60 3.3 Configuring an IO device through hardware detection .......................................................... 62 3.4 Specifying the router for a PROFINET IO device .................................................................. 64 3.5 3.5.1 3.5.2 3.5.3 3.5.4 3.5.5 3.5.6 3.5.7 Configuring topology .............................................................................................................. 68 Topology view in STEP 7 ....................................................................................................... 70 Interconnecting ports in the topology view ............................................................................. 71 Interconnecting ports - Inspector window .............................................................................. 73 Automatic assignment of devices by offline/online comparison ............................................ 74 Apply the port interconnections identified online manually to the project .............................. 75 Include the devices identified online manually in the project ................................................. 76 Automatic assignment of devices by advanced offline/online comparison ............................ 76 PROFINET with STEP 7 V15 8 Function Manual, 12/2017, A5E03444486-AH Table of contents 4 5 Diagnostics and maintenance ............................................................................................................... 77 4.1 4.1.1 4.1.2 4.1.2.1 4.1.2.2 4.1.2.3 Diagnostics mechanisms of PROFINET IO ............................................................................77 Diagnostics levels in PROFINET IO .......................................................................................79 Maintenance ...........................................................................................................................81 I&M data (identification and maintenance) .............................................................................81 Loading I&M data to PROFINET IO devices and your modules ............................................81 Asset management .................................................................................................................82 4.2 Diagnostics using status LEDs ...............................................................................................96 4.3 Diagnostics via the display of the S7-1500 CPUs ..................................................................97 4.4 Diagnostics via Web server ..................................................................................................100 4.5 Diagnostics in STEP 7 ..........................................................................................................103 4.6 Extended maintenance concept ...........................................................................................106 4.7 Diagnostics of the network topology .....................................................................................108 4.8 4.8.1 4.8.2 Diagnostics in the user program ...........................................................................................109 Diagnostics and configuration data records .........................................................................109 Evaluate diagnostics in the user program ............................................................................111 Functions ............................................................................................................................................ 113 5.1 5.1.1 5.1.2 5.1.3 Connecting other bus systems .............................................................................................113 Connecting other bus systems .............................................................................................113 Linking PROFINET and PROFIBUS .....................................................................................115 Connect the DP slave via the IE/PB Link to a PROFINET IO system ..................................116 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 5.2.10 Intelligent IO devices (I-devices)...........................................................................................118 I-device functionality .............................................................................................................118 Properties and Advantages of the I-Device ..........................................................................119 Characteristics of an I-Device ...............................................................................................120 Data Exchange between higher- and lower-level IO system ................................................123 Configuring the I-device ........................................................................................................125 Program examples ................................................................................................................127 Diagnostics and interrupt characteristics ..............................................................................130 Rules for the Topology of a PROFINET IO System with I-Device ........................................133 Boundary conditions when using I-devices ..........................................................................135 Configuring PROFIenergy with I-devices..............................................................................136 5.3 5.3.1 5.3.2 5.3.3 5.3.4 Shared device .......................................................................................................................138 Useful information on shared devices ...................................................................................138 Configuring shared device ....................................................................................................141 Configuring an I-device as a shared device..........................................................................145 Module-internal shared input/shared output (MSI/MSO) ......................................................154 5.4 5.4.1 5.4.2 5.4.3 5.4.4 Media redundancy (ring topologies) .....................................................................................161 Media Redundancy Protocol (MRP) .....................................................................................162 Configuring media redundancy .............................................................................................164 Media Redundancy with Planned Duplication of frames (MRPD) ........................................167 Multiple rings .........................................................................................................................169 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 9 Table of contents 5.5 5.5.1 5.5.2 5.5.3 5.5.4 5.5.5 5.5.6 5.5.7 5.5.8 Real-time communication .................................................................................................... 173 Introduction .......................................................................................................................... 173 RT ........................................................................................................................................ 174 IRT ....................................................................................................................................... 175 Comparison of RT and IRT .................................................................................................. 178 Configuring PROFINET IO with IRT .................................................................................... 178 Setting the bandwidth usage for the send clock .................................................................. 181 Setup recommendations for optimizing PROFINET ............................................................ 183 Limitation of the data infeed into the network ...................................................................... 187 5.6 5.6.1 5.6.2 5.6.3 5.6.4 5.6.5 PROFINET with performance upgrade ................................................................................ 189 Dynamic frame packing ....................................................................................................... 190 Fragmentation ...................................................................................................................... 191 Fast forwarding .................................................................................................................... 192 Configuration of IRT with high performance ........................................................................ 193 Sample configuration for IRT with high performance........................................................... 197 5.7 5.7.1 5.7.2 5.7.3 5.7.4 5.7.5 5.7.6 5.7.7 5.7.8 5.7.9 Isochronous mode ............................................................................................................... 198 What is isochronous mode?................................................................................................. 198 Use of isochronous mode .................................................................................................... 199 Isochronous applications ..................................................................................................... 199 Time sequence of synchronization ...................................................................................... 200 Basics of Programming ........................................................................................................ 201 Program processing according to the IPO model with application cycle = 1 ....................... 202 Program execution according to the IPO model with application cycle > 1 ......................... 204 Configuring isochronous mode ............................................................................................ 205 Setting the application cycle and delay time ........................................................................ 208 5.8 5.8.1 5.8.2 5.8.3 Device replacement without exchangeable medium ........................................................... 210 Device replacement without exchangeable medium/PG function ....................................... 211 Replacing an IO device without exchangeable medium ...................................................... 212 Permit overwriting of PROFINET device name ................................................................... 213 5.9 5.9.1 5.9.1.1 5.9.1.2 5.9.1.3 5.9.2 5.9.2.1 5.9.2.2 5.9.2.3 5.9.2.4 5.9.2.5 5.9.2.6 Standard machine projects .................................................................................................. 217 Multiple use IO systems ....................................................................................................... 218 What you should know about multiple use IO systems ....................................................... 218 Configuring multiple use IO systems ................................................................................... 221 Adapt multiple use IO systems locally ................................................................................. 224 Configuration control for IO systems ................................................................................... 226 Information about configuration control of IO systems ........................................................ 226 Configuring IO devices as optional ...................................................................................... 229 Enabling optional IO devices in the program ....................................................................... 230 Configuring flexible order of IO devices ............................................................................... 236 Customizing arrangement of IO devices in the program ..................................................... 238 System behavior and rules .................................................................................................. 241 5.10 Saving energy with PROFIenergy........................................................................................ 243 5.11 5.11.1 Docking systems .................................................................................................................. 246 Configuring docking systems ............................................................................................... 248 PROFINET with STEP 7 V15 10 Function Manual, 12/2017, A5E03444486-AH Table of contents 5.12 5.12.1 5.12.2 5.12.3 5.12.4 5.12.5 5.12.6 Accelerating startup ..............................................................................................................251 Options for accelerating the startup of IO devices ................................................................251 Prioritized startup ..................................................................................................................252 Configuring prioritized startup ...............................................................................................254 Optimize the port settings .....................................................................................................255 Optimize the cabling of the ports ..........................................................................................256 Measures in the user program ..............................................................................................257 Glossary ............................................................................................................................................. 258 Index................................................................................................................................................... 271 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 11 Documentation guide 1 The documentation for the SIMATIC S7-1500 automation system, for CPU 1516pro-2 PN based on SIMATIC S7-1500, and for the distributed I/O systems SIMATIC ET 200MP, ET 200SP and ET 200AL is divided into three areas. This division allows you easier access to the specific information you require. Basic information System manuals and Getting Started manuals describe in detail the configuration, installation, wiring and commissioning of the SIMATIC S7-1500, ET 200MP, ET 200SP and ET 200AL systems; use the corresponding operating instructions for CPU 1516pro-2 PN. The STEP 7 online help supports you in configuration and programming. Device information Product manuals contain a compact description of the module-specific information, such as properties, terminal diagrams, characteristics and technical specifications. PROFINET with STEP 7 V15 12 Function Manual, 12/2017, A5E03444486-AH Documentation guide General information The function manuals contain detailed descriptions on general topics such as diagnostics, communication, Motion Control, Web server, OPC UA. You can download the documentation free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742705). Changes and additions to the manuals are documented in product information sheets. You will find the product information on the Internet: ● S7-1500/ET 200MP (https://support.industry.siemens.com/cs/us/en/view/68052815) ● ET 200SP (https://support.industry.siemens.com/cs/us/en/view/73021864) ● ET 200AL (https://support.industry.siemens.com/cs/us/en/view/99494757) Manual Collections The Manual Collections contain the complete documentation of the systems put together in one file. You will find the Manual Collections on the Internet: ● S7-1500/ET 200MP (https://support.industry.siemens.com/cs/ww/en/view/86140384) ● ET 200SP (https://support.industry.siemens.com/cs/ww/en/view/84133942) ● ET 200AL (https://support.industry.siemens.com/cs/ww/en/view/95242965) "mySupport" With "mySupport", your personal workspace, you make the best out of your Industry Online Support. In "mySupport", you can save filters, favorites and tags, request CAx data and compile your personal library in the Documentation area. In addition, your data is already filled out in support requests and you can get an overview of your current requests at any time. You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en). "mySupport" - Documentation In the Documentation area in "mySupport" you can combine entire manuals or only parts of these to your own manual. You can export the manual as PDF file or in a format that can be edited later. You can find "mySupport" - Documentation on the Internet (http://support.industry.siemens.com/My/ww/en/documentation). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 13 Documentation guide "mySupport" - CAx data In the CAx data area in "mySupport", you can access the current product data for your CAx or CAe system. You configure your own download package with a few clicks. In doing so you can select: ● Product images, 2D dimension drawings, 3D models, internal circuit diagrams, EPLAN macro files ● Manuals, characteristics, operating manuals, certificates ● Product master data You can find "mySupport" - CAx data on the Internet (http://support.industry.siemens.com/my/ww/en/CAxOnline). Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system separated from the focus on individual products. You will find the application examples on the Internet (https://support.industry.siemens.com/sc/ww/en/sc/2054). TIA Selection Tool With the TIA Selection Tool, you can select, configure and order devices for Totally Integrated Automation (TIA). This tool is the successor of the SIMATIC Selection Tool and combines the known configurators for automation technology into one tool. With the TIA Selection Tool, you can generate a complete order list from your product selection or product configuration. You can find the TIA Selection Tool on the Internet (http://w3.siemens.com/mcms/topics/en/simatic/tia-selection-tool). PROFINET with STEP 7 V15 14 Function Manual, 12/2017, A5E03444486-AH Documentation guide SIMATIC Automation Tool You can use the SIMATIC Automation Tool to run commissioning and maintenance activities simultaneously on different SIMATIC S7 stations as a bulk operation, independently of the TIA Portal. The SIMATIC automation tool provides a variety of functions: ● Scanning of a PROFINET/Ethernet plant network and identification of all connected CPUs ● Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a CPU ● Transfer of the date and programming device/PC time converted to UTC time to the module ● Program download to CPU ● Operating mode switchover RUN/STOP ● CPU localization by means of LED flashing ● Reading out CPU error information ● Reading of CPU diagnostic buffer ● Reset to factory settings ● Updating the firmware of the CPU and connected modules You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network during commissioning. PRONETA features two core functions: ● The topology overview independently scans PROFINET and all connected components. ● The IO check is a fast test of the wiring and the module configuration of a plant. You can find SIEMENS PRONETA on the Internet (https://support.industry.siemens.com/cs/ww/en/view/67460624). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 15 Documentation guide SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves. This helps to prevent problems in commissioning or failures during productive operation even in advance of a planned operation. This increases the availability of the production plant and helps improve operational safety. The advantages at a glance ● Network optimization thanks to port-specific calculation of the network load ● Increased production availability thanks to online scan and verification of existing systems ● Transparency before commissioning through importing and simulation of existing STEP 7 projects ● Efficiency through securing existing investments in the long term and optimal exploitation of resources You can find SINETPLAN on the Internet (https://www.siemens.com/sinetplan). PROFINET with STEP 7 V15 16 Function Manual, 12/2017, A5E03444486-AH Description 2.1 2 Introduction to PROFINET What is PROFINET IO? Within the framework of Totally Integrated Automation (TIA), PROFINET IO is the logical further development of: ● PROFIBUS DP, the established fieldbus and ● Industrial Ethernet PROFINET IO is based on 20 years of experience with the successful PROFIBUS DP and combines the normal user operations with the simultaneous use of innovative concepts of Ethernet technology. This ensures the integration of PROFIBUS DP into the PROFINET world. PROFINET IO as the Ethernet-based automation standard of PROFIBUS/PROFINET International defines a cross-vendor communication, automation, and engineering model. Objectives of PROFINET The objectives of PROFINET: ● Industrial networking, based on Industrial Ethernet (open Ethernet standard) ● Compatibility of Industrial Ethernet and standard Ethernet components ● High robustness due to Industrial Ethernet devices. Industrial Ethernet devices are suited to the industrial environment (temperature, noise immunity, etc.). ● Use of IT standards such as TCP/IP, http. ● Real-time capability ● Seamless integration of other fieldbus systems PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 17 Description 2.1 Introduction to PROFINET Implementation of PROFINET in SIMATIC PROFINET is implemented in SIMATIC as follows: ● We have implemented communication between field devices in SIMATIC with PROFINET IO. ● Installation technology and network components are available as SIMATIC NET products. ● Ethernet standard protocol and procedures (e.g., SNMP = Simple Network Management Protocol for network parameter assignment and diagnostics) are used for remote maintenance and network diagnostics. Figure 2-1 PROFINET overview configuration PROFINET with STEP 7 V15 18 Function Manual, 12/2017, A5E03444486-AH Description 2.1 Introduction to PROFINET STEP 7 The STEP 7 engineering tool supports you in setting up and configuring an automation solution. STEP 7 provides a uniform application view over all bus systems. Documentation from PROFIBUS & PROFINET International on the Internet You will find numerous documents on the topic of PROFINET at the Internet address (http://www.profibus.com) of the "PROFIBUS & PROFINET International" PROFIBUS user organization, which is also responsible for PROFINET. Additional information can be found on the Internet (http://www.siemens.com/profinet). Overview of the most important documents and links A compilation of the most important PROFINET application examples, FAQs and other contributions in the Industry Online Support is available in this FAQ (https://support.industry.siemens.com/cs/ww/en/view/108165711). 2.1.1 PROFINET terms Definition: Devices in the PROFINET environment In the PROFINET environment, "device" is the generic term for: ● Automation systems (PLC, PC, for example) ● Distributed I/O systems ● Field devices (for example, hydraulic devices, pneumatic devices) ● Active network components (for example, switches, routers) ● Gateways to PROFIBUS, AS interface or other fieldbus systems PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 19 Description 2.1 Introduction to PROFINET PROFINET IO devices The following graphic shows the general names used for the most important devices in PROFINET. In the table below the graphic you can find the names of the individual components in the PROFINET IO context. Number PROFINET ① PROFINET IO System ② IO controller ③ ④ ⑤ ⑥ Programming device / PC (PROFINET IO supervisor) PROFINET/Industrial Ethernet HMI (Human Machine Interface) IO device ⑦ I-device Figure 2-2 Explanation Device used to address the connected IO devices. This means that: The IO controller exchanges input and output signals with field devices. PG/PC/HMI device used for commissioning and for diagnostics Network infrastructure Device for operating and monitoring functions. A distributed field device that is assigned to one of the IO controllers (e.g., Distributed IO, valve terminals, frequency converters, switches with integrated PROFINET IO functionality) Intelligent IO device PROFINET devices PROFINET with STEP 7 V15 20 Function Manual, 12/2017, A5E03444486-AH Description 2.1 Introduction to PROFINET IO communication via PROFINET IO The inputs and outputs of distributed I/O devices are read and written by means of PROFINET IO using what is referred to as IO communication. The following figure provides an overview of IO communication by means of PROFINET IO. A B C IO controller - IO controller communication via PN/PN coupler IO controller - I-device communication IO controller - IO-device communication Figure 2-3 IO communication via PROFINET IO PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 21 Description 2.1 Introduction to PROFINET IO communication via PROFINET IO Table 2- 1 IO communication via PROFINET IO Communication between ... Explanation IO controllers and IO devices The IO controller sends data cyclically to the IO devices of its PROFINET IO system and receives data from these devices. IO controller and I-device A fixed quantity of data is transferred cyclically between the user programs in CPUs of IO controllers and I-devices. The IO controller does not access the I/O module of the I-device, but instead accesses configured address ranges, i.e. transfer ranges, which may be located inside our outside the process image of the CPU of the I-device. If parts of the process image are used as transfer ranges, it is not permitted to use these for real I/O modules. Data transfer takes place using load- and transfer operations via the process image or via direct access. IO controller and IO controller A fixed quantity of data is cyclically transferred between the user programs in CPUs of IO controllers. A PN/PN coupler is required as additional hardware. The IO controllers mutually access configured address ranges, i.e. transfer ranges, which may be located inside or outside the process image of the CPU. If parts of the process image are used as transfer ranges, it is not permitted to use these for real I/O modules. Data transfer takes place using load- and transfer operations via the process image or via direct access. See also Communication (http://support.automation.siemens.com/WW/view/en/59192925) Network security (Page 38) Functions (Page 113) 2.1.2 Basic terminology of communication PROFINET communication PROFINET communication takes place via Industrial Ethernet. The following transmission types are supported: ● Acyclic transmission of engineering and diagnostics data and interrupts ● Cyclic transmission of user data The PROFINET-IO communication takes place in real-time. For additional information on the real-time communication, refer to chapter Real-time communication (Page 173). PROFINET with STEP 7 V15 22 Function Manual, 12/2017, A5E03444486-AH Description 2.1 Introduction to PROFINET Transparent data access Access to process data from different levels of the factory is supported by PROFINET communication. By using Industrial Ethernet, standard mechanisms of communication and information technology such as OPC/XML can now be used along with standard protocols such as UDP/TCP/IP and HTTP in automation engineering. This allows transparent access from company management level directly to the data from the automation systems at the control level and production level. ① ② ③ Management level Control level Production level Figure 2-4 Access to process data PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 23 Description 2.1 Introduction to PROFINET Update time The update time is a time interval. IO controller and IO device/I-device exchange IO data cyclically in the IO system within this time interval. The update time can be configured separately for each IO device and determines the interval at which output data is sent from the IO controller to the IO device (output module/submodule) as well as input data from the IO device to the IO controller (input module/submodule). STEP 7 calculates the update time automatically in the default setting for each IO device of the PROFINET IO system, taking into account the volume of data to be exchanged as well as the set send clock. For additional information on the update time, refer to section Real-time communication (Page 173). Watchdog time The watchdog time is the time interval that an IO controller or IO device permits, without receiving IO data. If the IO device is not supplied by the IO controller with data within the watchdog time, the device detects the missing frames and outputs substitute values. This is reported in the IO controller as a station failure. In STEP 7, the watchdog time is made up from an integral multiple of the update time and can be set by the user. Send clock The period of time between two consecutive communication cycles. The send clock is the shortest possible interval in data exchange. Relationship between the update time and send clock The calculated update times are reduction ratios (1, 2, 4, 8, ..., 512) of the send clock. The minimum possible update time thus depends on the minimum send clock of the IO controller that can be set and the efficiency of the IO controller and IO device. Depending on the send clock, it can be that only some of the reduction ratios are available (STEP 7 guarantees this through a pre-selection). The following tables illustrate the dependency of the update time that can be set on the send clock, using an example of the CPU 1516-3 PN/DP. The update times satisfy the requirements of the PROFINET standard IEC 61158. Table 2- 2 With real-time communication the following applies: Send clock Update time Reduction ratios 250 μs 250 μs to 128 ms 1,2, ..., 512 500 μs 500 μs to 256 ms 1,2, ..., 512 1 ms 1 ms to 512 ms 1,2, ..., 512 2 ms 2 ms to 512 ms 1,2, ..., 256 4 ms 4 ms to 512 ms 1,2, ..., 128 Additional information For information on real-time communication, refer to the section Real-Time Communication (RT) (Page 174). PROFINET with STEP 7 V15 24 Function Manual, 12/2017, A5E03444486-AH Description 2.1 Introduction to PROFINET 2.1.3 PROFINET interface Overview PROFINET devices of the SIMATIC product family have one or more PROFINET interfaces (Ethernet controller/interface). The PROFINET interfaces have one or more ports (physical connection options). In the case of PROFINET interfaces with multiple ports, the devices have an integrated switch. PROFINET devices with two ports on one interface allow you to configure the system in a line or ring topology. PROFINET devices with three or more ports on one interface are also ideal for setting up tree topologies. Properties and rules for naming the PROFINET interface and its representation in STEP 7 are explained in the following. Properties Every PROFINET device on the network is uniquely identified via its PROFINET interface. For this purpose, each PROFINET interface has: ● A MAC address (factory default) ● An IP address ● A PROFINET device name Identification and numbering of the interfaces and ports Interfaces and ports for all modules and devices in the PROFINET system are identified with the following characters: Table 2- 3 Identification for interfaces and ports of PROFINET devices Element Symbol Interface number Interface X In ascending order starting from number 1 Port P In ascending order starting from number 1 (for each interface) Ring port R PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 25 Description 2.1 Introduction to PROFINET Examples of identification Three examples illustrate the rules for identifying PROFINET interfaces: Table 2- 4 Examples for identifying PROFINET interfaces Sample labeling Interface number Port number X2 P1 2 1 X1 P2 1 2 X1 P1 R 1 1 (ring port) Representation of PROFINET Interfaces in the Topology Overview in STEP 7 You can find the PROFINET interface in the topology overview in STEP 7. The PROFINET interface for an IO controller and an IO device is represented as follows in STEP 7: Number ① ② ③ ④ Description PROFINET interface of an IO controller in STEP 7 PROFINET interface of an IO device in STEP 7 These lines represent the PROFINET interface. These lines represent the "ports" of a PROFINET interface. Figure 2-5 Representation of the PROFINET interfaces in STEP 7 Schematic Representation of a PROFINET Interface with Integrated Switch The following schematic diagram shows the PROFINET interface with integrated switch and its ports for all PROFINETdevices. Figure 2-6 PROFINET interface with integrated switch PROFINET with STEP 7 V15 26 Function Manual, 12/2017, A5E03444486-AH Description 2.1 Introduction to PROFINET Functional differences of the PROFINET interfaces PROFINET interfaces can provide different functions. PROFINET interface functions include identification, configuration, diagnostics and communication services (e.g., open communication). PROFINET interfaces that provide PROFINET IO functions and network security functions are also available. The following table illustrates the differences using the example of the CPU 1516-3 PN/DP (as of firmware version V2.0), which features two PROFINET interfaces with different functionality. Table 2- 5 Differences between the PROFINET interfaces of the CPU 1516-3 PN/DP (as of firmware version V2.0) PROFINET interface (X1) PROFINET interface (X2) 2 ports with PROFINET IO functionality: 1 port with PROFINET IO functionality: Identification, configuration and diagnostics PG communication HMI communication S7 communication Time-of-day synchronization Web server Open communication OPC UA server IO controller I-device RT IRT - Isochronous mode - Media redundancy - Prioritized startup - Additional Information on the Functionality of PROFINET interfaces You can find information on the number and functionality of the interfaces of a PROFINET device in the documentation for the specificPROFINET device. PROFINET communication services are described in the Communication function manual. In the Network security section you can find components that are used to protect networks against hazards. The Functions section describes the PROFINET IO functions. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 27 Description 2.1 Introduction to PROFINET 2.1.4 Implementation of the PROFINET device model in SIMATIC Slots and modules A PROFINET device can have a modular and compact structure. A modular PROFINET device consists of slots into which the modules are inserted. The modules have channels which are used to read and output process signals. A compact device has the same design and can include modules, however, it cannot be physically expanded, which means that no modules can be inserted. This is illustrated by the following graphic. Figure 2-7 Configuration of a PROFINET device Number Description ① ② ③ ④ Slot with bus interface Slot with module Subslot with submodule Channel A module can contain multiple submodules. PROFINET with STEP 7 V15 28 Function Manual, 12/2017, A5E03444486-AH Description 2.1 Introduction to PROFINET Representation of PROFINET Device Model in the Device View of STEP 7 The following figure shows the representation of the PROFINET device model in the device view of STEP 7, based on the example of a distributed I/O system ET 200MP: Figure 2-8 PROFINET device model in the device view of STEP 7 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 29 Description 2.2 Setting up PROFINET 2.2 Setting up PROFINET Contents of this chapter The following chapter provides background information on building your communication network. ● Overview of the most important passive network components: These are network components that forward a signal without the possibility of actively influencing it, for example, cables, connectors, etc. ● Overview of the most important active network components: These are network components that actively affect a signal, for example switches, routers, etc. ● Overview of the most common network structures (topologies). Physical connections of industrial networks PROFINET devices can be networked in industrial systems in two different physical ways: ● Connected line – By means of electrical pulses via copper cables – By means of optical pulses via fiber-optic cables ● Wireless via wireless network using electromagnetic waves PROFINET devices and cabling technology in SIMATIC are suited for industrial use, as they are based on Fast Ethernet and Industrial Ethernet. ● Fast Ethernet You can use Fast Ethernet to transfer data at a speed of 100 Mbps. This transmission technology uses the 100 Base-T standard for this. ● Industrial Ethernet Structure of Ethernet in industrial environment. The biggest difference from standard Ethernet is the mechanical current carrying capacity and noise immunity of the individual components. PROFINET with STEP 7 V15 30 Function Manual, 12/2017, A5E03444486-AH Description 2.2 Setting up PROFINET 2.2.1 Active Network Components Introduction The following active network components are available for PROFINET: ● Switch ● Router Switched Ethernet PROFINET IO is based on switched Ethernet with full-duplex operation and a bandwidth of 100 Mbps. In this way, the network can be used much more efficiently through the simultaneous data transfer of several devices. The PROFINET IO frames are processed with high priority. Switches Switches are network components used to connect several terminal devices or network segments in a local network (LAN). For the communication of a device with several other devices on PROFINET, the device is connected to the port of a switch. Other communication devices (including switches) can then be connected to the other ports of the switch. The connection between a communication device and the switch is a point-to-point connection. A switch has the task of receiving and distributing frames. The switch "learns" the Ethernet address(es) of a connected PROFINET device or additional switches and only forwards those frames that are intended for the connected PROFINET device or the connected switch. Switch variants Switches are available in two models: ● Integrated into a PROFINET device For PROFINET devices with multiple ports (two or more), we are dealing with devices with an integrated switch (for example, CPU 1516-3 PN/DP). ● As autonomous device (for example, switches of the SCALANCE product family) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 31 Description 2.2 Setting up PROFINET Selection Guide for Switches To use PROFINET with the RT class "RT", you can use any switch of "PROFINET Conformance Class A" or higher. All switches of the SCALANCE product family meet these requirements. If you want to use PROFINET functions that provide an additional value, such as topology recognition, diagnostics, device exchange without exchangeable medium/programming device, you have to use a switch of the "PROFINET Conformance Class B" or higher. To use PROFINET with the RT class "IRT", you must use a switch of "PROFINET Conformance Class C". With switches of the SCALANCE product family, watch out for the catalog feature "IRT PROFINET IO switch". To select appropriate switches, we recommend the SIMATIC NET Selection Tool on the Internet (http://support.automation.siemens.com/WW/view/en/39134641). Switches of the SCALANCE product family Use the switches of the SCALANCE product family if you want to use the full scope of PROFINET. They are optimized for use in PROFINET IO. In the SCALANCE X device family, you will find switches with electrical and optical ports and with a combination of both variants. SCALANCE X202-2IRT, for example, has two electrical ports and two optical ports and supports IRT communication. Beginning with the SCALANCE X200, you can configure, diagnose and address switches of the SCALANCE X device series as PROFINET IO devices using STEP 7. Router A router connects separated network segments with each other (e.g. management level and control level). The volume of data volume must be coordinated with the services of the respective network segment. A router also separates two networks and acts as a mediator between both networks. It thus reduces the network load. Routing functionality is provided in the SCALANCE X device family, with SCALANCE X300 or higher. Communication devices on different sides of a router can only communicate with one another if you have explicitly enabled communication between them via the router. If you want to access manufacturing data directly from SAP, for example, use a router to connect your Industrial Ethernet in the factory with the Ethernet in your office. Note If devices need to communicate beyond the limits of a network, you must configure the router so that it allows this communication to take place. Information on routing with STEP 7 is available in the function manual Communication (http://support.automation.siemens.com/WW/view/en/59192925). PROFINET with STEP 7 V15 32 Function Manual, 12/2017, A5E03444486-AH Description 2.2 Setting up PROFINET 2.2.2 Cabling technology Cables for PROFINET Electrical and optical cables are available for PROFINET. The type of cable depends on the data transfer requirements and on the ambient conditions. Simple method for the prefabrication of twisted pair cables When you set up your PROFINET system, you can cut the twisted-pair cable to the required length on site, strip it with the stripping tool (for Industrial Ethernet), and fit the Industrial Ethernet Fast Connect RJ45 plugs using the cut-and-clamp method. For more information on installation, refer to the installation instructions in the "SIMATIC NET Industrial Ethernet Network Manual" (http://support.automation.siemens.com/WW/view/en/8763736). Note A maximum of four plug-in pairs are allowed between two switches per Ethernet path. Simple method for the prefabrication of fiber-optic cables The FastConnect FO cabling system is available for the easy, fast and error-free prefabrication of fiber-optic cables. The glass-fiber optic cable consists of: ● FC FO Termination Kit for SC and BFOC plug (cleave tool, Kevlar scissors, buffer grip, fiber remains container) ● FC BFOC Plug ● FC SC Duplex plug ● FO FC Standard cable ● FO FC Trailing cable Simple method for the prefabrication of POF and PCF cables The following special tools provide an easy and safe way to prefabricate POF / PCF cables and fit the SC RJ POF plugs: ● POF cable Prefabrication case IE Termination Kit SC RJ POF plug ● PCF cable Prefabrication case IE Termination Kit SC RJ PCF plug PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 33 Description 2.2 Setting up PROFINET Overview of transmission media with PROFINET The following table summarizes the technical specifications of a PROFINET interface with integrated switch or an external switch, and possible transmission media. Table 2- 6 Transmission media with PROFINET Physical properties Connection methods Cable type / transmission medium Electrical RJ45 connector ISO 60603-7 100Base-TX Transmission rate / mode Max. segment length (between two devices) Advantages 100 Mbps, full duplex 100 m Simple and cheap cable connection 100 Mbps, full duplex 50 m Use when there are large differences in potential standard 2x2 twisted, symmetrical and shielded copper cable, CAT 5 transmission requirement IEEE 802.3 Optical SCRJ 45 100Base-FX ISO/IEC 61754-24 POF fiber-optic cable (Polymer Optical Fiber, POF) Insensitive towards electromagnetic radiation 980/1000 µm (core diameter / external diameter) ISO/IEC 60793-2 Plastic-cladded glass fiber (Polymer Cladded Fiber, PCF) 100 Mbps, full duplex 100 m 100 Mbps, full duplex 26 km 100 Mbps, full duplex 3000 m Low line attenuation Considerably longer segments possible1 200/230 µm (core diameter / external diameter) ISO/IEC 60793-2 BFOC (Bayonet Fiber Optic Connector) and SC (Subscriber Connector) Monomode glass fiber optic cable ISO/IEC 60874 ISO/IEC 60793-2 10/125 µm (core diameter / external diameter) Multimode glass fiber optic cable 50/125 µm and 62.5/125 µm (core diameter / external diameter) ISO/IEC 9314-4 Electroma gnetic waves 1 - IEEE 802.11 x Depends on the 100 m extension used (a, g, h, etc.) Greater mobility Cost-effective networking to remote, difficult to access devices Applies for fiber-optic cables only PROFINET with STEP 7 V15 34 Function Manual, 12/2017, A5E03444486-AH Description 2.2 Setting up PROFINET See also PROFINET interface (Page 25) Assembly Instructions for SIMATIC NET Industrial Ethernet (http://support.automation.siemens.com/WW/view/en/27069465) PROFINET Installation Guideline (http://www.profibus.com/nc/download/installationguide/downloads/profinet-installation-guide/display/) 2.2.3 Wireless design 2.2.3.1 Basics What is Industrial Wireless LAN? In addition to data communication in accordance with the IEEE 802.11 standard, the SIMATIC NET Industrial Wireless LAN provides a number of enhancements which offer significant benefits for industrial customers. IWLAN is particularly suitable for demanding industrial applications that require reliable wireless communication. This is supported by the following properties: ● Automatic roaming when the connection to Industrial Ethernet is interrupted (Forced Roaming) ● Cost savings generated by using a single wireless network for reliable operation of a process with both process-critical data (alarm message, for example) and non-critical communication (service and diagnostics, for example) ● Cost-effective connection to devices in remote environments that are difficult to access ● Predictable data traffic (deterministic) and defined response times ● Cyclical monitoring of the wireless link (link check) Objectives and advantages of Industrial Wireless LAN Wireless data transmission achieves the following objectives: ● Seamless integration of PROFINET devices into the existing bus system via the wireless interface ● Mobile use of PROFINET devices for different production-linked tasks ● Flexible configuration of the system components for fast development in accordance with customer requirements ● Maintenance costs are minimized by savings in cables PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 35 Description 2.2 Setting up PROFINET Application examples ● Communication with mobile subscribers (mobile controllers and devices, for example), conveyor lines, production belts, translation stages , and rotating machines ● Wireless coupling of communication segments for fast commissioning or cost-effective networking where routing of wires is extremely expensive (e.g. public streets, railroad lines) ● Stacker trucks, automated guided vehicle systems and suspended monorail systems The following graphic illustrates the many possible applications and configurations for SIMATIC device family wireless networks. Figure 2-9 Application example for the use of Industrial Wireless LAN Data transmission rate In Industrial Wireless LAN, gross data transmission rates of 11 Mbps or 54 Mbps without full duplex are permitted. PROFINET with STEP 7 V15 36 Function Manual, 12/2017, A5E03444486-AH Description 2.2 Setting up PROFINET Range With SCALANCE W (access points), wireless networks can be set up indoors and outdoors. Multiple access points can be installed to create large wireless networks in which mobile subscribers are transferred seamlessly from one access point to another (roaming). As an alternative to a wireless network, point-to-point connections of Industrial Ethernet segments can also be set up over large distances (several hundred meters). In this case, the range and characteristics of the RF field are determined by the antennas used. Note Range The range can be considerably less, depending on spatial factors, the wireless standard used, the data rate, and the antennas on the send and receive sides. 2.2.3.2 Tips on assembly Wireless networks, SCALANCE device family With PROFINET, you can also set up wireless networks with Industrial Wireless Local Area Network (IWLAN) technology. We recommend implementing the SCALANCE W device line for this. Update time in STEP 7 If you set up PROFINET with Industrial Wireless LAN, you may have to increase the update time for the wireless devices. The IWLAN interface provides lower performance than the wired data network: Several communication stations have to share the limited transmission bandwidth. For wired solutions, 100 Mbps is available for each communication device. The Update time parameter can be found in the "Realtime settings" section in the Inspector window of IO devices in STEP 7. Figure 2-10 Update time in STEP 7 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 37 Description 2.2 Setting up PROFINET Additional information More information about SCALANCE W Industrial Wireless LAN components can be found in the manual SIMATIC NET SCALANCE W-700 (http://support.automation.siemens.com/WW/view/en/42784493). More information about wired data transmission can be found in the manual SIMATIC NET Twisted Pair and Fiber Optic Networks (http://support.automation.siemens.com/WW/view/en/8763736). More information about wireless data transmission can be found in the manual Basics for configuring an industrial wireless LAN (http://support.automation.siemens.com/WW/view/en/9975764). You should also read the PROFINET installation guideline of the PROFIBUS User Organization on the Internet (http://www.profibus.com/nc/download/installationguide/downloads/profinet-installation-guide/display/). Various documents that assist with the setting up of your PROFINET automation solution are available here: ● PROFINET planning guideline ● PROFINET installation guideline ● PROFINET commissioning guideline ● Additional documents for setup of PROFINET 2.2.4 Network security 2.2.4.1 Basics Introduction The topic of data security and access protection (Security) has become increasingly important in the industrial environment. The increased networking of entire industrial systems, vertical integration and networking of levels within a company and new techniques such as remote maintenance all result in higher requirements for protecting the industrial plant. Data security solutions for office environments cannot simply be transferred one-to-one to industrial applications to protect against manipulation in sensitive systems and production networks. Requirements Additional security requirements arise from the specific communication requirements in the industrial environment (real-time communication, for example): ● Protection against interaction between automated cells ● Protection of network segments ● Protection against faulty and unauthorized access ● Scalability of network security ● Must not influence the network structure PROFINET with STEP 7 V15 38 Function Manual, 12/2017, A5E03444486-AH Description 2.2 Setting up PROFINET Definition of security Generic term for all the measures taken to protect against: ● Loss of confidentiality due to unauthorized access to data ● Loss of integrity due to manipulation of data ● Loss of availability due to destruction of data, for example, through faulty configuration and denial-of-service attacks Threats Threats can arise from external and internal manipulation. The loss of data security is not always caused by intentional actions. Internal threats can arise due to: ● Technical errors ● Operator errors ● Defective programs Added to these internal threats there are also external ones. The external threats are not really any different to the known threats in the office environment: ● Software viruses and worms ● Trojans ● Man-in-the-middle attacks ● Password Phishing ● Denial of Service PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 39 Description 2.2 Setting up PROFINET Protective measures The most important precautions to prevent manipulation and loss of data security in the industrial environment are: ● Filtering and control of data traffic by means of firewall ● A virtual private network (VPN) is used to exchange private data on a public network (Internet, for example). The most common VPN technology is IPsec. IPsec (Internet Protocol Security) is a collection of security protocols that are used as the basis for the IP protocol at the mediation level and allow a secured communication via potentially unsecure IP networks. ● Segmenting in protected automation cells This concept has the aim of protecting the lower-level network devices by means of security modules. A group of protected devices forms a protected automation cell. ● Authentication (identification) of the devices The security modules identify each other over a safe (encrypted) channel using authentication procedures. It is therefore impossible for unauthorized parties to access a protected segment. ● Encrypting the data traffic The confidentiality of data is ensured by encrypting the data traffic. Each security module is given a VPN certificate which includes the encryption key. 2.2.4.2 Network components and software Protection against unauthorized access The following solutions may be used to connect industrial networks to the intranet and Internet to protect against internal and external threats: ● Communication processors, such as the SIMATIC CP 1543-1 ● SCALANCE X-300 and SCALANCE S - the data security components of the SIMATIC NET product family ● SOFTNET security client for use on PCs Features Both of these products have a wide variety of features, such as: ● Easy integration of existing networks without configuration, with integrated firewall. ● Segmenting in protected automation cells ● Authentication (identification) of the devices ● Encrypting the data traffic PROFINET with STEP 7 V15 40 Function Manual, 12/2017, A5E03444486-AH Description 2.2 Setting up PROFINET 2.2.4.3 Application example Data security at the office and production levels The following graphic contains an application example with protected areas at different levels of the company created using SCALANCE S and the security client. The protected areas are highlighted in light gray. Figure 2-11 Network configuration with the SCALANCE S security module and the SOFTNET security client PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 41 Description 2.2 Setting up PROFINET Additional information Additional information on the configuration of a security standard in PROFINET, is available: ● In the PROFINET security guideline. These guidelines can be found on the homepage of the PROFIBUS user organization on the Internet (http://www.profinet.com). ● In the Industrial Ethernet Security (http://support.automation.siemens.com/WW/view/en/56577508) manual ● In the SCALANCE S and SOFTNET Security Client (http://support.automation.siemens.com/WW/view/en/21718449) manual You can find general information on industrial security concepts, functions and news on the Industrial Security website (http://www.siemens.com/industrialsecurity). PROFINET with STEP 7 V15 42 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3 To set up an automation system, you will need to configure, assign parameters and interlink the individual hardware components. In STEP 7, the work needed for this is undertaken in the device, topology and network view. Configuring "Configuring" is understood to mean arranging, setting and networking devices and modules within the device, topology or network view. An I/O address is automatically assigned to each module. The I/O addresses can be subsequently modified. The CPU compares the configuration preset in STEP 7 with the actual current configuration of the system. In this way, potential errors can be detected and reported straight away. The exact procedure for configuring devices is described in detail in the STEP 7 online help. Assigning parameters "Assigning parameters" is understood to mean setting the properties of the components used. The settings for the hardware components and for data communication are configured at the same time. In STEP 7, you can "assign parameters" for the following settings PROFINET: ● Device names and IP address parameters ● Port interconnection and topology ● Module properties / parameters The parameters are loaded into the CPU and transferred to the corresponding modules when the CPU starts up. Modules are easy to replace from spare parts, as the parameters assigned for the SIMATIC CPUs are automatically loaded into the new module at each startup. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 43 Parameter assignment/addressing Adjusting the hardware to the project requirements You need to configure hardware if you want to set up, expand or change an automation project. To do this, add hardware components to your structure, link these with existing components, and adapt the hardware properties to the tasks. The properties of the automation systems and modules are preset such that in many cases they do not have to be assigned parameters again. Parameter assignment is however needed in the following cases: ● You want to change the default parameter settings of a module. ● You want to use special functions. ● You want to configure communication connections. PROFINET with STEP 7 V15 44 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.1 Assigning an IO device to an IO controller 3.1 Assigning an IO device to an IO controller PROFINET IO System A PROFINET IO system is comprised of a PROFINET IO controller and its assigned PROFINET IO devices. After these devices have been placed in the network or topology view, STEP 7 assigns default values for them. Initially, you only have to worry about the assignment of IO devices to an IO controller. Requirement ● You are in the network view of STEP 7. ● A CPU has been placed (e.g., CPU 1516-3 PN/DP). ● An IO device has been placed (e.g., IM 155-6 PN ST). Procedure To assign IO devices to an IO controller, proceed as follows: 1. Place the pointer of the mouse over the interface of the IO device. 2. Press and hold down the left mouse button. 3. Move the pointer. The pointer now uses the networking symbol to indicate "Networking" mode. At the same time, you see the lock symbol on the pointer. The lock symbol disappears only when the pointer is over a valid target position. 4. Now move the pointer onto the interface of the IO controller. You can keep the left mouse button pressed or release it when performing this action. 5. Now release the left mouse button or press it again (depending on your previous action). Figure 3-1 Assigning an IO device to an IO controller in the network view of STEP 7 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 45 Parameter assignment/addressing 3.1 Assigning an IO device to an IO controller Result You have assigned an IO device to an IO controller. Checking the assignment You can find an overview of the communication relationships in the "IO communication" tab in the tabular area of the network view. This table is context-sensitive for selection in the graphic area: ● Selection of the interface shows the I/O communication of the respective interface. ● Selection of the CPU shows all I/O communication of the CPU (including PROFIBUS). ● Selection of the station (as in the above figure) interface shows the I/O communication of the complete station. PROFINET with STEP 7 V15 46 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address 3.2 Device name and IP address Introduction In order that the PROFINET device can be addressed as node on PROFINET, the following are required: ● A unique PROFINET device name ● A unique IP address in the relevant IP subnet STEP 7 assigns a device name during the arrangement of a PROFINET device in the hardware and network editor. The IP addresses are typically assigned automatically by STEP 7 and assigned to the devices based on the device name. You can change the name and IP address manually. In STEP 7 You can find the device name and the IP address under "Ethernet addresses" in the properties of the PROFINET interface in the Inspector window. Figure 3-2 Device name and IP address in STEP 7 The function, the assignment and the changing of the device name and the IP address are described in the following sections. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 47 Parameter assignment/addressing 3.2 Device name and IP address 3.2.1 Device name Device names Before an IO device can be addressed by an IO controller, it must have a device name. In PROFINET, this method was selected because it is simpler to work with names than with complex IP addresses. The assignment of a device name for a specific IO device can be compared to setting the PROFIBUS address of a DP slave. In delivery state, an IO device does not have a device name. A device name must first be assigned before an IO device can be addressed by an IO controller, for example, for transferring configuration data during startup or for exchanging user data in cyclic mode. You assign the device names to the IO device, for example, with the programming device / PC. IO devices that have a slot for removable storage media provide the option of writing the device name directly to the removable storage medium in the programming device. When a device is replaced by a device without removable medium, the IO controller assigns the device name based on topological configuration (see section Configuring topology (Page 68)). Structured device names The device name is automatically assigned by default for PROFINET devices S7-1200, S7-1500, ET 200MP, ET 200SP and ET 200AL when these are configured in STEP 7. The device names are formed from the name of the CPU or the name of the interface module. For devices with several PROFINET interfaces, the name of the interface is enhanced, for example, "plc_1.profinet-interface_2" or "io-device_1". You can structure the device names using DNS conventions. These conventions are defined by "Internationalizing Domain Names in Applications (IDNA). According to this, device names are written in lower case. The "Domain Name System" (DNS) is a distributed database (http://iana.org), which manages the name space on the Internet. To structure the names, you use the dot ("."). The hierarchy is shown in ascending order from left to right. .... . If the name is not DNS-compliant, the name will be converted by STEP 7, for example, to "plcxb1.profinet-schnittstellexb2022c" or "io-devicexb15b32". PROFINET with STEP 7 V15 48 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address Device number In addition to the device name, STEP 7 also assigns a device number beginning with "1" when an IO device is allocated. The device number is located in the Inspector window in the properties of the PROFINET interface, under "Ethernet addresses" in the area PROFINET. Figure 3-3 Device number This device number can be used to identify an IO device in the user program (for example, with the instruction "LOG2GEO"). 3.2.2 IP address IP address To allow a PROFINET device to be addressed as a device on Industrial Ethernet, this device also requires an IP address that is unique within the network. The IP addresses are typically assigned automatically by STEP 7 and assigned to the devices based on the device name. If it is a standalone network, you can apply the IP address and subnet mask suggested by STEP 7. If the network is part of an existing Ethernet company network, obtain the information from your network administrator. Configuration of the IP address In accordance with Internet Protocol version 4 (IPv4), the IP address is made up of four decimal numbers with a range of values from 0 through 255. The decimal numbers are separated by periods (for example, 192.162.0.0). The IP address consists of the following: ● Address of the network ● Address of the device (PROFINET interface of the IO controller/IO device) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 49 Parameter assignment/addressing 3.2 Device name and IP address Generating IP addresses The IP addresses of the IO devices are generated by STEP 7 and first assigned to the IO devices when the CPU starts up. In addition, for some IO devices (e.g., SCALANCE X, S7-300 CPs), it is possible not to obtain the IP address during startup of the IO controller, but rather to set it beforehand on the device (see Permitting changes to the device name and IP address directly on the device (Page 60)). The IP addresses of the IO devices always have the same subnet mask as the IO controller and are assigned from the IP address of the IO controller in ascending order. The IP address can be changed manually, if necessary. For devices with several PROFINET interfaces (e.g., CPU 1516-3 PN/DP), the IP addresses must be located in different subnets. Default router The default router is used when data has to be forwarded via TCP/IP or UDP to a partner located outside the local network. In STEP 7, the default router is named Router. You can activate the use of a router in the Inspector window of a CPU with the "Use router" check box in the "IP protocol" section. STEP 7 assigns the local IP address to the default router by default. The router address that is set on the PROFINET interface of the IO controller is automatically transferred for the configured IO devices. Subnet mask The bits set in the subnet mask decide the part of the IP address that contains the address of the network. In general, the following applies: ● The network address is obtained from the AND operation of the IP address and subnet mask. ● The device address is obtained from the AND NOT operation of the IP address and subnet mask. Example of the subnet mask Subnet mask: 255.255.0.0 (decimal) = 11111111.11111111.00000000.00000000 (binary) IP address: 192.168.0.2 (decimal) = 11000000.10101000.00000000.00000010 (binary) Meaning: The first 2 bytes of the IP address determine the network - i.e., 192.168. The last two bytes address the device, i.e. 0.2. PROFINET with STEP 7 V15 50 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address Relation between IP address and default subnet mask An agreement exists relating to the assignment of IP address ranges and so-called "Default subnet masks". The first decimal number (from the left) in the IP address determines the structure of the default subnet mask with respect to the number of "1" values (binary) as follows: IP address (decimal) IP address (binary) Address class Default subnet mask 0 to 126 0xxxxxxx.xxxxxxxx.... A 255.0.0.0 128 to 191 10xxxxxx.xxxxxxxx... B 255.255.0.0 192 to 223 110xxxxx.xxxxxxxx... C 255.255.255.0 Note Range of values for the first decimal point A value between 224 and 255 is also possible for the first decimal number of the IP address (address class D etc.). However, this is not recommended because there is no address check for these values. Masking other subnets You can use the subnet mask to add further structures and form "private" subnets for a subnet that is assigned one of the address classes A, B or C. This is done by setting other, less significant bits of the subnet mask to "1". For each bit set to "1", the number of "private" networks doubles and the number of devices they contain is halved. Externally, the network continues to function as an individual network. Example: You have a subnet of address class B (for example, IP address 129.80.xxx.xxx) and change the default subnet mask as follows: Masks Decimal Binary Default subnet mask 255.255.0.0 11111111.11111111.00000000. 00000000 Subnet mask 255.255.128.0 11111111.11111111.10000000. 00000000 Result: All devices with addresses from 129.80.001.000 to 129.80.127.254 are located in a subnet, all devices with addresses from 129.80.128.000 to 129.80.255.254 in a different subnet. Reading out an IP address in the user program You can read out the IP address of a PROFINET device in the user program of a S7-1500 CPU. You can find information in this FAQ (https://support.industry.siemens.com/cs/ww/en/view/82947835). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 51 Parameter assignment/addressing 3.2 Device name and IP address 3.2.3 Assigning a device name and IP address Assigning an IP address and subnet mask for an IO controller for the first time You have the following options: ● Using a programming device or PC: Connect your programming device/PC to the same network as the relevant PROFINET device. The interface of the programming device/PC must be set to TCP/IP mode. During the download, first of all display all available devices via the "Accessible devices" download dialog box. Select the target device via its MAC address and then assign its IP address before you download the hardware configuration including the configured IP address (IP address is saved retentively). ● Using the display of a S7-1500 CPU: The S7-1500 CPUs have a front cover with a display and operating keys. You can use this display to assign or change the IP address. To set the IP address, navigate on the display via the menu items "Settings" > "Addresses" > "X1 (IE/PN)" > "Parameters". ● Using a memory card: If your PROFINET device is equipped for a memory card (Micro Memory Card/SIMATIC memory card), plug this into your programming device/PC and save the hardware configuration together with the configured IP address on this memory card. Then plug the memory card into the PROFINET device. Once inserted, the PROFINET device automatically applies the IP address. If you have saved a configuration to the memory card with the "IP address is set directly at the device" option, you must assign the IP address using a different method after inserting the memory card (see section Permitting changes to the device name and IP address directly on the device (Page 60)). Assigning device names and IP address for "Device replacement without exchangeable medium/programming device" For devices without exchangeable medium (e.g., ET 200MP, ET 200SP) and devices that support "Device replacement without exchangeable medium/PG" (e.g., ET 200S), the IO controller can identify the device without name from the neighbor relationships specified by the set topology and from actual neighbor relationships determined by the real PROFINET devices. The IO controller then assigns the PROFINET device the configured name and incorporates the PROFINET device in the user data traffic. (See also Device replacement without exchangeable medium (Page 210)). PROFINET with STEP 7 V15 52 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address IP address assignment when replacing IO devices with exchangeable mediumPG The following is contained on the memory card of the programmable logic controller: ● On the IO controller: Device name and IP address ● On the IO device: Device name When you remove the memory card from a PROFINET device and insert it in another PROFINET device with exchangeable medium (e.g., ET 200S), device-specific information and the device name are loaded to the device. If an IO device has to be replaced in its entirety due to a device or module defect, the IO controller automatically assigns parameters and configures the replaced device or module. The cyclic exchange of user data is then restarted. In addition to this, before the power ON of the IO device, the memory card with the valid name must be removed from the faulty IO device and added to the replaced device. In the event of an error in the PROFINET device, the memory card allows you to replace a module without a programming device/PC. You can also transfer the device data directly from the programming device/PC to the memory card. Procedure: Changing the device name using properties of the PROFINET interface You can change the PROFINET name via the properties of the PROFINET interface. This is useful when the PROFINET device has not received its previous name from the automatic generation, for example, in the case of a migration. 1. In the network or device view of the STEP 7 hardware and network editor, select the PROFINET interface of a PROFINET device. 2. In the Inspector window, go to "Ethernet addresses" in the PROFINET area. 3. Clear the "Generate PROFINET device name automatically" check box. 4. Enter the new PROFINET device name in the relevant field. Figure 3-4 Changing the device name of a PROFINET device in the properties PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 53 Parameter assignment/addressing 3.2 Device name and IP address Alternative procedure: Changing the device name of a PROFINET device in the network view Requirement: The "Generate PROFINET device name automatically" check box is selected. 1. In STEP 7, select the "Network overview" tab in the tabular area of the network view. 2. In the "Device" column, overwrite the name in the row of the relevant PROFINET device. The name is also changed accordingly in the graphic area of the network view. Figure 3-5 Changing the device name of a PROFINET device in STEP 7 PROFINET with STEP 7 V15 54 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address Procedure: Changing the IP address To change the IP address, follow these steps: 1. In the network or device view of the STEP 7 hardware and network editor, select the PROFINET interface of a PROFINET device. 2. In the Inspector window, go to "Ethernet addresses" in the "IP protocol" area. 3. Check that the option "Set IP address in the project" is selected. 4. Enter the new IP address in the relevant field. Figure 3-6 Changing the IP address of a PROFINET device in STEP 7 Downloading configured device name to IO device To load the configured device names to the IO device, follow these steps: 1. Connect your programming device/PC to the same network as the relevant IO device. The interface of the programming device/PC must be set to TCP/IP mode. 2. In STEP 7, select the relevant IO device in the "Accessible devices" dialog based on the MAC address. 3. Click "Assign name" to download the configured device name to the IO device. The IO controller recognizes the IO device automatically by its device name and automatically assigns the configured IP address to it. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 55 Parameter assignment/addressing 3.2 Device name and IP address Identification of the PROFINET device To clearly identify a device from several identical devices in a control cabinet, for example, you can flash the link LED of the PROFINET device. To do this, select the menu command Online > Accessible devices... in STEP 7. In the "Accessible devices" dialog, set the "PG/PC" interface by means of which you are connected to the devices. STEP 7 now automatically searches for the accessible devices and displays them in the "Accessible devices in target subnet" table. Select the desired PROFINET device and click on the "Flash LED" button. The PROFINET device is identified based on its MAC address. Figure 3-7 "Accessible devices" dialog Using an different way to assign IP addresses for IO devices Various IO devices, for example, SCALANCE X,S7-300 CPs, support the option of not having the IP addresses assigned by the IO controller during startup. In this case, the IP address is assigned in a different way. For additional information, refer to the manual of the respective PROFINET device of the SIMATIC device family. PROFINET with STEP 7 V15 56 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address Additional information You can find a detailed description of the operation and functions of the display of the S7-1500 CPUs in the system manual S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792). 3.2.4 Assign device name via communication table Introduction You can assign the device names of PROFINET IO devices configured offline to the devices online. You can do this in the table area of the network view in the table "I/O communication". You can also assign the device names to several devices at the same time. "Online assignment" tab In the I/O communication table, you will find the tabs "Offline configuration" and "Online assignment". In the "Online assignment" tab, you can assign the PROFINET device names that were assigned offline to the corresponding IO devices online. To do this, use the buttons "Check devices" and "Assign now". Figure 3-8 Assign device name via communication table The objects displayed in the table of the "Online assignment" tab depend on the setting of the filter function. If only selected objects should be displayed, only objects of the corresponding context are displayed depending on the selection in the network view. ● PROFINET subnet: All connected devices and their PROFINET interfaces ● IO system All devices involved and their PROFINET interfaces ● Sync domain: All devices involved and their PROFINET interfaces ● Devices: The device and any existing PROFINET interfaces ● Other subnets or interfaces such as MPI or PROFIBUS are not displayed If the display is set for all devices using the filter function, all devices are displayed that have a PROFINET interface, regardless of whether they are connected via a PROFINET subnet or are part of an IO system. Devices without a PROFINET interface, for example only with a DP or MPI interface, are not displayed. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 57 Parameter assignment/addressing 3.2 Device name and IP address General procedure To assign PROFINET device names, you must first detect the IO devices available online. With this procedure, it matters whether the MAC addresses are known or unknown. This results in a general procedure in two steps: 1. Detecting the IO devices available online 2. Assigning configured PROFINET device names to the IO devices available online Requirements ● You are in the network view. ● There is an online connection to the devices. Procedure (step 1) To detect IO devices available online from the I/O communication table, follow these steps: 1. Optional: Entered known MAC addresses in the "MAC address" column. After every valid entry, the check box under "Assign device" is selected for the relevant row. Note You can enter, insert or import the MAC address in different formats. The correct format is automatically entered in the cell. The following entries are supported and then converted to the required format: • "08:00:06:BA:1F:20" • "08 00 06 BA 1F 20" • "080006BA1F20" The formats used in the example are automatically converted to "08-00-06-BA-1F-20". 2. Click "Check devices" to start the check of the IO devices available online. 3. Set the PG/PC interface in the dialog window and click "Start". PROFINET with STEP 7 V15 58 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address Intermediate result After the check, the result is displayed for every device in the table. Online data found is automatically entered in the table and the check box "Assign device" is set to "checked" in the rows in which a MAC address was entered or found online. The result of the check is shown as an icon in the "Status" column. Status Meaning Matching device and compatible type Matching device and incompatible type Non-matching device Device cannot be reached (with a known MAC address) Ready for assignment (with known MAC address) Note The icon "Ready for assignment" appears when a MAC address exists and matching device data was found, but no PROFINET device name was found online. You can update the data of the detected devices again via their MAC addresses at any time. To do this, you specify the MAC address and the status of the device is displayed immediately without having to re-detect the device. Procedure (step 2) All PROFINET device names configured offline will be assigned to the devices available online in a bulk operation. 1. Click the "Assign now" button. Note The bulk operation cannot be reversed. A message to this effect appears in a dialog window. 2. Click "Start" in the dialog window to start the assignment of the PROFINET device names. Result The PROFINET device names configured offline will be assigned to the devices available online. This relates to devices in whose row the check box under "Assign device" is selected, that have a MAC address and have the status "Ready for assignment". PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 59 Parameter assignment/addressing 3.2 Device name and IP address Importing and exporting data Using the import and export button, you can import or export the data of the I/O communication table for the online assignment: ● When you export, the currently displayed data of the table is exported to a CSV file. Using the filter function of the table, you can select which data will be exported. ● When you import, the data of the CSV file is written to the table. If there are conflicts with values already existing in the table, you can decide whether the data should be overwritten or whether the import needs to be stopped. 3.2.5 Permitting changes to the device name and IP address directly on the device Introduction Machines are frequently commissioned on site or integrated into the existing infrastructure without STEP 7. You can find typical applications in all areas of the series machine building. Alternative means for assigning the IP address are available for this. Procedure 1. In the network or device view of the STEP 7 Hardware and Network editor, select the PROFINET interface of an IO controller. 2. Navigate in the Inspector window to "Ethernet addresses". 3. Select the "IP address is set directly at the device" option in the "IP protocol" area. PROFINET with STEP 7 V15 60 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.2 Device name and IP address 4. In the "PROFINET" area, select the " PROFINET device name is set directly at the device" check box. Figure 3-9 Setting the device name and IP address on the device Note Gateway When you operate a PROFINET device with the option "Allow adaption of the device name/IP address directly on device", you cannot use this PROFINET device as gateway for S7 routing. Options for assigning IP addresses and device names Apart from the known address and device name assignment in the "Ethernet addresses" section of the Inspector window, there are other ways in which the IP address and name can be assigned: ● Assigning by means of the user program with the instruction "T_CONFIG" ● Assignment when downloading the configuration to the target system via the "Extended download to device" dialog box. ● Assignment via the Primary Setup Tool (PST) ● Assignment via the PRONETA ("PROFINET network analysis") commissioning and diagnostics tool ● Assignment via the SIMATIC Automation Tool Additional information For information on the "T_CONFIG" instruction and on downloading to the target system, refer to the STEP 7 online help. A free Download (http://support.automation.siemens.com/WW/view/en/14929629) of the Primary Setup Tool (PST) can be found on the Internet. On this Internet page, you will also find a list of devices for which the PST is approved. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 61 Parameter assignment/addressing 3.3 Configuring an IO device through hardware detection 3.3 Configuring an IO device through hardware detection Introduction As of STEP 7 V15, you have the possibility to detect a real existing IO device and to import it into your project. You find the IO device in STEP 7 through the "Hardware detection" function. A detected device can be imported into your project. STEP 7 inserts the IO device with all the modules and submodules. Prerequisites ● STEP 7 (TIA Portal) as of V15 ● It must be possible to technically access the IO device via IP Procedure Proceed as follows to detect one or more existing IO devices in STEP 7 and to import them into the project: 1. In STEP 7, navigate to "Online" > "Hardware detection". 2. Click "IO devices". STEP 7 opens the "Hardware detection of IO devices." 3. Select the interface of your programming device at "PG/PC interface:". 4. Click "Start search". STEP 7 begins with the hardware detection. When the hardware detection is completed, STEP 7 displays all the detected IO devices. 5. Select the IO devices that you want to import into the project by clicking the corresponding check box before the IO device. 6. Click "Add devices". After a brief moment, a window is opens to report about the success or failure of the hardware detection. PROFINET with STEP 7 V15 62 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.3 Configuring an IO device through hardware detection Result of the hardware detection If the hardware detection is successful, STEP 7 inserts the IO device with all the modules and submodules into the project. An IO device configured via hardware detection responds as follows: ● Modules configured through the "Hardware detection" are configured as if they have been inserted from the catalog. ● MAC address: STEP 7 imports the MAC address of the detected IO device into the project. ● IP settings: – If the detected IO device already has an IP address, STEP 7 imports the IP address into the project. – If the detected IO device does not have an IP address, STEP 7 automatically assigns an IP address in the project. PROFINET device name: – If the detected IO device already has a PROFINET device name, STEP 7 imports the PROFINET device name into the project. – If the detected IO device does not have a PROFINET device name, STEP 7 automatically assigns a PROFINET device name in the project. ● IO devices configured through "Hardware detection" have neither an IP subnet nor an IO controller assigned. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 63 Parameter assignment/addressing 3.4 Specifying the router for a PROFINET IO device 3.4 Specifying the router for a PROFINET IO device Introduction You always require a router (also referred to as a "Standard Gateway") when the PROFINET device has to communicate with a node whose IP addresses lie outside the own IP subnet. If the PROFINET device sends an IP packet to an IP address outside its own IP subnet, the IP packet first goes to the configured router. The router in turn checks the IP address. If this lies outside its own subnet, the router passes the IP packet on to the next router. The IP packet is routed to the next router until it has reached the target address. Like all S7-1500 CPUs, S7-1500 CPUs with several PROFINET interfaces provide the possibility to configure the IP address of a router. However, there is the restriction that you can only enter the IP address of a router at a PROFINET interface. You cannot include an IP address of a router on the other PROFINET interfaces of the CPU. IO devices that are connected to this PROFINET interface adopt this setting. Up to and including STEP 7 V14 SP1, these IO devices did not have any possibility to reach devices in a different IP subnet. As of STEP 7 V15, you have the possibility to assign the address of a router for an IO device independent of the setting of the IO controller. You can now, for example, set a router address at the IO device in the following cases as well: ● You have not set an IP address of a router for the interface of the associated IO controller. ● You have already set a router address for a different interface in the CPU. ① ② ③ ④ Router R1 configured at PROFINET X1 If a router is configured at X1, you cannot configure a router at X2. Because a router is configured at X1, the IO device adopts the IP address of the router R1. The IO device can be reached from a different IP subnet. As of STEP 7 V15, you set the IP address of the router R2 at the IO device irrespective of the setting at the interface X2. The IO device can be reached from a different IP subnet. Figure 3-10 Specifying the router for an IO device PROFINET with STEP 7 V15 64 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.4 Specifying the router for a PROFINET IO device Further information about the "User router" setting You have the possibility to configure the use of a router including IP address of the router in the "IP protocol" section of the settings for the PROFINET interface (Ethernet addresses). Rules Observe the following rules if you want to configure a router for the PROFINET interface of an IO controller: ● A PROFINET IO device supports exactly one router, irrespective of the number of interfaces. ● You can configure a router for exactly one PROFINET interface. All IO devices that are assigned to the PROFINET interface adopt the configured router from the IO controller. ● You cannot configure a router for the further PROFINET interfaces of the CPU. The further PROFINET interfaces take on the IP address "0.0.0.0" as the router and pass it on to their IO devices. As of STEP 7 V15, you can configure the use of a router for an IO device. This allows the IO device to communicate with a node outside its own IP subnet, irrespective of the setting of the PROFINET interface of the IO controller. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 65 Parameter assignment/addressing 3.4 Specifying the router for a PROFINET IO device Configuration example: Configuring a router for an IO device The following example shows a configuration in which you configure a router at the IO device so that the IO device reaches IP addresses in the higher-level network. Figure 3-11 Configuration example: Configuring a router for an IO device You have a CPU 1516-3PN/DP. The two PROFINET interfaces X1 and X2 of the CPU work in the "IO controller" operating mode. The PROFINET interface X1 is connected with the subnet "Production line 1". PROFINET interface X2 is connected with the subnet "Production line 2". The two subnets "Production line 1" and "Production line 2" are each connected via a router with the higher-level network "Superior line". For PROFINET X1, you configure the router "Router 1" with the IP address 192.168.1.100. The IO device (ET 200SP) in the "Production line 1" subnet adopts the router from the IO controller. You cannot configure a router for the PROFINET interface X2 because you have already configured a router for the PROFINET interface X1 of the CPU. No router is transferred by the PROFINET interface X2 to the IO device in the subnet "Production line 2". In order for the IO device in the subnet "Production line 2" to reach nodes in the higher-level "Superior line", configure the router "Router 2" with the IP address 192.168.2.100 for the IO device. PROFINET with STEP 7 V15 66 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.4 Specifying the router for a PROFINET IO device Configuring the router for the IO controller Requirements: You use the "Set IP address in the project" option for the PROFINET interface. Follow these steps to configure a router for the IO controller in STEP 7: 1. In the network view of STEP 7, select the PROFINET interface of the IO controller. 2. In the Inspector window, navigate to "Properties" > "General" > "Ethernet addresses". 3. Select the "Use router" check box in the "IP protocol" field. 4. Enter the IP address of the router at "Router address". Configuring a router for an IO device Requirements: ● STEP 7 as of V15 ● CPU 1500 as of firmware version V2.5 ● IO device is assigned to the PROFINET interface of an IO controller. The PROFINET interface of the IO controller uses the "Set IP address in the project" option. Follow these steps to configure a router for the IO device in STEP 7: 1. In the network view of STEP 7, select the PROFINET interface of the IO device. 2. In the Inspector window, navigate to "Properties" > "General" > "Ethernet addresses". 3. Clear the "Synchronize router settings with IO controller" check box. 4. Select the "Use router" check box. 5. Enter the IP address of the router at "Router address". PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 67 Parameter assignment/addressing 3.5 Configuring topology 3.5 Configuring topology Introduction If an IO device is assigned to an IO controller, this does not yet specify how the ports are connected to each other. A port interconnection is not required to use RT, but it provides the following advantages: ● A set topology is assigned with the port interconnection. Based on an online-offline comparison, it is possible to conduct a set-actual comparison with all devices that support this function. ● The "Device replacement without exchangeable medium" function can be used. A port interconnection is an essential requirement for using IRT. An overview of various options for setting up a PROFINET network is given below. Line All the communication devices are connected in a linear bus topology. In PROFINET, the linear bus topology is implemented with switches that are already integrated into the PROFINET devices. Therefore, the linear bus topology at PROFINET is merely a special form of tree / star topology. If a link element (switch, for example) fails, communication across the failed link element is no longer possible. The network is then divided into 2 subsegments. Linear bus topology structures require the least cabling. Star If you connect communication devices to a switch with more than two PROFINET ports, you automatically create a star network topology. If an individual PROFINET device fails, this does not automatically lead to failure of the entire network, in contrast to other structures. It is only if a switch fails that part of the communication network will fail as well Tree If you interconnect several star structures, you obtain a tree network topology. Ring In order to increase the availability of a network, use ring structures. In principle, a linear bus topology is connected to a ring through a so-called redundancy manager. The task of the redundancy manager is managed by an external switch SCALANCE X, a CPU that supports the Media Redundancy Protocol MRP (e.g., CPU 1516-3 PN/DP) or a CP (e.g., CP 343-1 Lean). If there is a break in the network, the redundancy manager ensures that the data is redirected over an alternative network connection in the ring. PROFINET with STEP 7 V15 68 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.5 Configuring topology Example for topology The following example shows a combination of different topologies. Number Meaning ① S7-1500 as IO controller ② S7-300 as IO controller ③ Industrial WLAN with SCALANCE W ④ SCALANCE X 307-3 with seven electrical and three optical ports ⑤ ET 200SP with integrated 2-port switch ⑥ SCALANCE X 204 with four electrical ports ⑦ PROFINET/Industrial Ethernet ⑧ IE/PB-Link PN IO ⑨ PROFIBUS DP ⑩ ET 200S with two optical ports Star topology Linear bus topology The combination of topology forms results in a tree topology. Figure 3-12 Combined topology PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 69 Parameter assignment/addressing 3.5 Configuring topology Additional information Observe the PROFINET Installation Guideline (http://www.profibus.com/nc/download/installation-guide/downloads/profinet-installationguide/display/) of the PROFIBUS User Organization when planning your PROFINET topology. For more detailed information, see the SIMATIC NET Twisted Pair and Fiber Optic Networks (http://support.automation.siemens.com/WW/view/en/8763736) manual. You can find basic information in the Communication with SIMATIC (http://support.automation.siemens.com/WW/view/en/1254686) manual. 3.5.1 Topology view in STEP 7 Introduction The topology view is one of three working areas of the hardware and network editor. You undertake the following tasks here: ● Displaying the Ethernet topology ● Configuring the Ethernet topology ● Identify and minimize differences between the set and actual topology (online) The topology view in STEP 7 consists of a graphic area and a table area. Graphic area The graphic area of the topology view displays PROFINET devices with their appropriate ports and port connections. Here you can add more PROFINET devices. The following figure shows the graphic area of the topology view. ① ② ③ ④ ⑤ Selector: Device view/Network view/Topology view Toolbar Graphic area of the topology view Overview navigation Selector for the table area of the topology view Figure 3-13 Graphic area of the topology view PROFINET with STEP 7 V15 70 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.5 Configuring topology Overview navigation Click in the overview navigation to obtain an overview of the created objects in the graphic area. By holding down the mouse button, you can quickly navigate to the desired objects and display them in the graphic area. Table area ● Topology overview: This displays the Ethernet or PROFINET devices with their appropriate ports and port connections in a table. This table corresponds to the network overview table in the network view. ● Topology comparison: Here you can import devices and port interconnections automatically through offline/online comparison or extended Offline/Online comparison into STEP 7. ① ② ③ ④ Selector for the graphic area of the topology view Selector: Device view/Network view/Topology view Selector: Topology overview/Topology comparison Table area of the topology view Figure 3-14 Table area of the topology view 3.5.2 Interconnecting ports in the topology view Requirement You are in the graphic view of the topology view. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 71 Parameter assignment/addressing 3.5 Configuring topology Procedure To interconnect ports in the topology view, follow these steps: 1. Place the pointer of the mouse on the port you want to interconnect. 2. Press and hold down the left mouse button. 3. Move the pointer. The pointer now uses the networking symbol to indicate "Interconnecting" mode. At the same time, you see the lock symbol on the pointer. The lock symbol disappears only when the pointer is over a valid target position. 4. Now drag the pointer to the target port. You can keep the left mouse button pressed or release it when performing this action. 5. Now release the left mouse button or press it again (depending on your previous action). Figure 3-15 Interconnecting ports in the topology view Result You have created a port interconnection. PROFINET with STEP 7 V15 72 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.5 Configuring topology 3.5.3 Interconnecting ports - Inspector window Interconnecting ports in the Inspector window To interconnect ports, follow these steps: 1. In the device or network view, select the PROFINET device or PROFINET interface. 2. In the Inspector window, navigate to the port property "Port interconnection". When the PROFINET interface is selected, you can find this setting in the Inspector window as follows: "Properties > General > Advanced Options > Port [...] > Port Interconnection." 3. In the "Local port" section, you can find the settings at the local port. In the case of fiberoptic cable you can, for example, set the cable names here. In the "Partner port" area, select the drop-down list for "Partner port" in order to display the available partner ports and make a selection. Figure 3-16 Interconnecting ports in the Inspector window in STEP 7 If the PROFINET interface was disconnected, it is automatically connected by this action. In the properties of the subnet you can set whether this subnet should or should not be used for the networking. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 73 Parameter assignment/addressing 3.5 Configuring topology 3.5.4 Automatic assignment of devices by offline/online comparison Overview During the offline/online comparison, the configured topology is compared with the actual existing topology. Devices identified online are automatically assigned to configured devices as far as this is possible. Start of availability detection You start the availability detection the first time by clicking the "Compare offline/online" button in the toolbar of the "Topology comparison" tab. You restart availability detection by clicking the "Update" button. Note The availability detection can take several seconds. During this time, no user input is possible. Automatic assignment of a PNIO device A PNIO device identified online is automatically assigned to a configured device if the following properties of the two devices match up: ● Article no. ● Type ● PROFINET device name No automatic assignment In the following situations, no automatic assignment is possible: ● No device can be identified online to match a configured device. (This means that the corresponding columns in the "Online topology" area of the topology comparison table are empty.) In this case, you should add the already configured device to your system or delete the configured device from the configuration. ● A device identified online can be assigned to a configured device, but there are differences in the port interconnections. In this case, you can Apply the port interconnections identified online manually to the project (Page 75). ● A device identified online cannot be assigned to a configured device. (In this case, the corresponding columns in the "Offline topology" area of the topology comparison table are empty.) In this case, you can Include the devices identified online manually in the project (Page 76). PROFINET with STEP 7 V15 74 Function Manual, 12/2017, A5E03444486-AH Parameter assignment/addressing 3.5 Configuring topology 3.5.5 Apply the port interconnections identified online manually to the project Requirements You have run an offline/online comparison in the topology view. The result of this is that at least one device identified online was automatically assigned to a configured device, but that there are differences relating to the interconnection. Procedure To adopt one more port interconnections identified online in the project manually, follow these steps: 1. Select the row belonging to the port interconnection. 2. If applicable, select further roles using multi-selection. 3. Select "Apply" > "Use selected" in the shortcut menu. The content of the corresponding table cells in the "Action" column changes to "Apply". 4. If you have mistakenly prepared too many port interconnections to be included in the project: Select the rows belonging to the port interconnections you have mistakenly prepared for inclusion in the project using multi-selection. Select "Reset" > "Reset selected" in the shortcut menu. The content of the corresponding table cells in the "Action" column change to "No action". 5. Click the "Synchronize" button. Result The port interconnections identified online for the corresponding devices are included in the project. Successful adoption is indicated by the diagnostics icon "Identical topology information" for each port. Note If other port interconnections are recognized for a device identified online and these differ from those that exist in the project, adopting these in the project means that the port interconnections that were previously in the project are replaced by those identified online. If no port interconnections are detected for a device identified online, adopting in the project means that all the port interconnections of this device are deleted in the project. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 75 Parameter assignment/addressing 3.5 Configuring topology 3.5.6 Include the devices identified online manually in the project Requirements You have run an offline/online comparison in the topology view. The result of this is that at least one device identified online could not be assigned to any configured device. Procedure To adopt one more devices identified online in the project manually, follow these steps: 1. For a configured device without an online partner, move the mouse pointer to the "Device/port" column of the online topology. 2. Select the device you want to assign to the configured device from the drop-down list of this box. 3. Repeat the previous steps if necessary for other configured devices without an online partner. Result The selected device that was identified online is moved up from the end of the table. Following this, it is in the row of the configured device to which you have just assigned it. 3.5.7 Automatic assignment of devices by advanced offline/online comparison Overview With the advanced offline/online comparison, ICMP is also used alongside DCP to be able to detect devices that do not support DCP. Automatic assignment of devices detected by ICMP With devices detected by ICMP, no type is available. With passive devices, no article number is available. For this reason, passive devices can only be assigned automatically if you have not assigned an article number in the configured data and the offline and online IP addresses match. With switches, automatic assignment is possible if the offline and online article number, IP address and PROFINET device name match. PROFINET with STEP 7 V15 76 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 4 Diagnostics mechanisms of PROFINET IO Totally Integrated Diagnostics Concept All SIMATIC products have integrated diagnostics functions that they can use to detect and remedy faults. The components automatically flag a potential fault in the operation and provide detailed information. Each individual error or several errors occurring concurrently are transferred from the IO device to the IO controller. If you require the full status of the IO device including any pending errors, you can also read the status directly from the IO device. The following sections provide basic information on using diagnostics via PROFINET IO. You can find a detailed description of the system diagnostics for S7-1500, ET 200MP, ET 200SP and ET 200AL in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function manual. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 77 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Accessing the status of an IO device with a PG/PC or an HMI device If you are connected to the Industrial Ethernet via a PG/PC with STEP 7 or an HMI device, you can also call up diagnostics information online. This is illustrated by the following graphic. Number ① ② ③ Description The IO device detects an error and sends diagnostics data to the IO controller. The IO controller notifies the programming/HMI device. The display of the system diagnostics is updated. In STEP 7, you can read the station status for "Accessible devices" directly from the IO device regardless of the IO controller. This is only possible if the programming device is connected to Industrial Ethernet. This means that you can access diagnostics information during the commissioning phase or for servicing even if the IO controller is not operational. Figure 4-1 PROFINET IO diagnostics with PG/PC or HMI device PROFINET with STEP 7 V15 78 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO 4.1.1 Diagnostics levels in PROFINET IO Concept The IO device sends all error messages that occur to the IO controller. The scope and volume of diagnostics information varies according to the level of diagnostics data evaluation and the PROFINET devices you are using. Diagnostics levels You can evaluate diagnostics data at different levels. The number and type of channels is selected, for example, at the diagnostics level 4. The following figure shows the diagnostics levels with PROFINET IO. Figure 4-2 Diagnostics levels with PROFINET IO PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 79 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Representation of diagnostics levels in the device view in STEP 7 The following figure shows the representation of the PROFINET device model in the device view of STEP 7, based on the example of a distributed I/O system ET 200MP: Number ① ② Description Level 1: Level 2: Error(s) in the device Error(s) in the module Figure 4-3 Diagnostics levels in the device view of STEP 7 Which PROFINET nodes support the extended PROFINET diagnostics? An overview of the PROFINET nodes that support extended PROFINET diagnostics and of what you have to configure is provided in this FAQ (https://support.industry.siemens.com/cs/ww/en/view/23678970). PROFINET with STEP 7 V15 80 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO 4.1.2 Maintenance 4.1.2.1 I&M data (identification and maintenance) Definition and properties Identification and maintenance data (I&M) is information saved to module memory in order to provide support when: ● Checking the plant configuration ● Locating hardware changes in a plant Identification data (I data) is module information (some of which may be printed on the module housing) such as the order and serial number. I data is read-only vendor-specific module data. Maintenance data (M data) is plant-specific information such as the location identifier and installation date. M data is created during configuration. The modules can be uniquely identified in online mode by means of the I&M data. Further information To find out whether and to what extent a PROFINET device supports I&M data, refer to the documentation of the relevant device. 4.1.2.2 Loading I&M data to PROFINET IO devices and your modules Which I&M data can be loaded to PROFINET IO devices and your modules? You can load I&M 1 data (plant designation and location identifier) and/or I&M 2 data (installation date) and/or I&M 3 data (additional information) to the actual hardware. Requirements ● In the project settings (Options > Settings, Hardware configuration > Compiling and downloading), the option "Download I&M data" must be enabled. ● There is an online connection to the PROFINET IO devices and the modules to which you want to load I&M data. ● You have entered the I&M data you want to download in the properties of the respective PROFINET IO devices and your modules (Inspector window: "Properties" tab > "General" tab, Settings > Identification & Maintenance). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 81 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Where do I specify which I&M data is downloaded to which PROFINET IO devices? You specify which I&M data you want to download to which PROFINET IO devices in the "Load preview" dialog. You will find the following alternatives in the drop-down list of the "Identification and maintenance data (I&M)" row: ● Load nothing The check boxes for all PROFINET IO devices as well as the check boxes for the loadable I&M data are cleared. No I&M data is transferred to the actual hardware during loading with this setting. ● Load data The check boxes for all PROFINET IO devices as well as the check boxes for the loadable I&M data are selected. The respective I&M 1, I&M 2 and I&M 3 data is transferred to all PROFINET IO devices during loading with this setting. ● Load selected You select the check boxes of those PROFINET IO devices to which you want to load I&M data. You also select the check boxes of the identification data you want to load. With this setting, you transfer the selected I&M data to the selected PROFINET IO devices during loading. Note Language dependency of the I&M data to be loaded The I&M data are loaded to the real hardware in the form that you specified in the properties of the relevant PROFINET IO devices and your modules. There is no language dependency. 4.1.2.3 Asset management Further information about asset management at PROFINET Operation of machines and plants without a detailed knowledge of devices and assets is difficult to imagine. Maintenance requires data for this – data that is extensive and up-to-date as far as possible. The requirement of greater transparency with regard to the data made available by plant components has been fulfilled by PROFIBUS & PROFINET International (PI): The identification and maintenance data familiar since PROFIBUS times have been extended. The current PROFINET fulfills this requirement through the definition of a special data record: the Asset Management Record (AMR). The aim of this definition is to enable you to acquire all the components to be maintained online - and not only those components that can be addressed and accessed through the PROFINET device model (Device / Module / Submodule). PROFINET now also reaches non-PROFINET components! PROFINET with STEP 7 V15 82 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Assets general and asset management data records Assets are components (hardware and software / firmware) of a machine, for example a laser welding machine, or a plant. A large number of these device components can already be identified through tried-andtested I&M functions or corresponding data records (I&M0 to I&M5) in the PROFINET context: The device itself as well as its modules and submodules. Meaning all components that can be addressed through the PROFINET device model. Components that cannot be addressed via the PROFINET device model, but whose data it should be possible to acquire online for operation and maintenance, can be identified through asset management functions. This asset management data (short: AM data) is stored in a defined structure in a special data record, the asset management record (AMR) mentioned above. The PROFINET Guideline "Identification & Maintenance Functions" differentiates here between I&M functions (I&M data) and asset management functions (AM data): The following sections only deal with the AM data. The components that can be read additionally online through asset management data records include both hardware components, such as backplane bus modules of a device as well as firmware components such as a drive control unit with own versioning. Application examples Importing asset management records enables you to read the following information during installation or operation, for example: ● Are only approved devices being used (whitelist check)? ● A firmware update is due. Obtain a fast overview: Which devices or components are affected and have to be upgraded? Making asset management data available The concept for the asset management of PROFINET devices stipulates that the manufacturers of PROFINET devices have to ensure that non-PROFINET automation components are made available through an asset management record. This data record is assigned to the PROFINET device. In contrast to a "standard" IO device, with an I-device the project engineer has to make the asset management record available. In this case, the central modules of the I-device are assets. From the perspective of PROFINET, these central modules are not visible from the point of view of the higher-level IO controller. The higher-level IO controller only "sees" the transfer areas through which it exchanges IO data with the I-device. The principle of this provision is explained in the section. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 83 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Reading asset management data The asset management record has the index 0xF880 and is read with standard PROFINET mechanisms by the user of the records, for example a tool or program for evaluating these data. A user program in the S7-1500 IO controller, for example, can read out the AMR of an IO device with the RDREC instruction (Index 0xF880). It is not possible to write to this data record. Further information Whether and to which extent a PROFINET device supports asset management data, meaning whether it makes an AMR available, is specified in the documentation of the respective device. Content and structure of an asset management record Basic structure of the asset management record You are first provided with an overview of the general structure of the record. The following table describes the framework within which the asset management data blocks are embedded. Each data block represents an asset, a terminal block for example. Element of the data structure Designation according to IEC 61158-6-10 Code Data type / length in bytes Header AssetManagementData BlockType 0x0035 UINT / 2 BlockLength Number of bytes without UINT / 2 counting the bytes for BlockType and BlockLength BlockVersion 0x0100 UINT / 2 NumbersOfEntries Number of AssetManagementBlocks UINT / 2 AssetManagementBlock 1 See the table below AssetManagementInfo AssetManagementBlocks (n) AssetManagementBlock 2 ... AssetManagementBlock n PROFINET with STEP 7 V15 84 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Structure of asset management blocks Each AssetManagementBlock contains identification data and localization information for an asset. An AssetManagementBlock has a substructure with basic characteristics described below. The header of an AssetManagementBlocks contains the coded information about which of the three possible AM data compilations the record contains. Devices make a suitable BlockType available in accordance with the various device types: ● Complex devices with information about the hardware and firmware (BlockType "AM_FullInformation") ● Complex devices with information about the hardware (BlockType "AM_HardwareOnlyInformation") ● Devices with information about the firmware (BlockType "AM_FirmwareOnlyInformation") The differentiation provides an efficient data structure below the header. Nevertheless, the data record can have a considerable size (maximum of 64 KB, depending on the number of assets that the IO device supplies). Table 4- 1 Structure of AssetManagementBlock Element of the data structure Designation according to IEC 61158-6-10 Code Data type / length in bytes Header AssetManagementBlock BlockType 0x0036 (AM_FullInformation) UINT / 2 0x0037 (AM_HardwareOnlyInformation) 0x0038 (AM_FirmwareOnlyInformation) BlockLength Number of bytes without counting the bytes for BlockType and BlockLength UINT / 2 BlockVersion 0x0100 UINT / 2 Padding 0x0000 (padding byte) USINT / 1 Padding 0x0000 (padding byte) USINT / 1 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 85 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Element of the data structure Designation according to IEC 61158-6-10 Code AssetManagementBlock IM_UniqueIdentifier Manufacturer-generated Universal Unique Array of Byte / 16 Identifier (UUID) conforming to ISO/IEC 98348. Used as a reference key to uniquely identify this asset. (Structure depends on the BlockType. Here it is shown using AM_FullInformation as an example) Data type / length in bytes Example: 550c5300-d34a-22b4-11d35533991111 AM_Location Description of the location of the asset: Array of Byte / 16 Either slot-oriented ("Slot and SubslotNumber format") or hierarchical ("Twelve level tree format"). See following description IM_Annotation Manufacturer-specific notation Example: "Terminal block, Type xyz123 ". Array of Char / 64 64 bytes are always used. Spaces are used for padding if the string is shorter. IM_OrderID Manufacturer-specific article number Array of Char / 64 Example: "6ES7 131-6BF00-0BA0 ". 64 bytes are always used. Spaces are used for padding if the string is shorter. AM_SoftwareRevision Manufacturer-specific SW version (not at Example: "V6.3.8 ". AM_HardwareOnlyInformati 64 bytes are always used. Spaces are used on) for padding if the string is shorter. Array of Char / 64 If the asset supports IM_Software_Revision, the AM_SoftwareRevision is padded with spaces. AM_HardwareRevision Manufacturer-specific hardware version (not at Example: "A4 ". AM_FirmwareOnlyInformati 64 bytes are always used. Spaces are used on) for padding if the string is shorter. Array of Char / 64 If the asset supports IM_Hardware_Revision, the AM_HardwareRevision is padded with spaces. IM_Serial_Number Manufacturer-specific unique productionrelated number. Array of Char / 16 The characters come from the visible range (0x20 ... 0x7E), no control characters. Example: "A78C-1C82 ". 16 bytes are always used. Spaces are used for padding if the string is shorter. PROFINET with STEP 7 V15 86 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Element of the data structure Designation according to IEC 61158-6-10 Code IM_Software_Revision Software version, follows a strict structure (SW version prefix, for example "V", digits for (not at AM_HardwareOnlyInformati functional extension, digits for BugFix, digits for internal change). on) Example: 'V' 0x01 0x2 0x3 Data type / length in bytes Array of Byte / 4 Prefix (character "V", "R", "P", "U", or "T"), then 3 digits "0" to "9" If AM_SoftwareRevision is padded with spaces, you should evaluate IM_Software_Revision. If the asset does not support any hardware, the coding 'V' 0x00 0x00 0x00. AM_DeviceIdentification Identification of the device. The structure is as Array of Byte / 8 follows: AM_DeviceIdentification.DeviceSubID (for SIEMENS e.g. 0x0000) AM_DeviceIdentification.DeviceID (Device ID from manufacturer, 0x0000 to 0xFFFF) AM_DeviceIdentification.VendorID (Example for Siemens assets: 0x002A) AM_DeviceIdentification.Organization: Example for Siemens assets: 0x0000 (PROFINET) AM_TypeIdentification Manufacturer-allocated type identification: UINT / 2 0x0000: Unspecified 0x0001: Controller (PLC) 0x0002: PC-based 0x0003: IO module, IO submodule 0x0004: Communications module / submodule 0x0005: Interface module / submodule 0x0006: Active network component 0c0007: Media attached unit (bus adapter) 0x0100 to 0x7FF: Manufacturer-specific IM_Hardware_Revision Version of the hardware (0x0000 to 0xFFFF) (not at AM_FirmwareOnlyInformati on) Example: 0x0003 UINT / 2 If AM_HardwareRevision is padded with spaces, you should evaluate IM_Hardware_Revision. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 87 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO AM_Location Asset management at PROFINET supports two formats for coding the location of an asset: ● Slot-oriented format ("Slot and SubslotNumber format") ● Hierarchical format ("Twelve Level Tree format" abbreviated LT format) Assets that are part of the PROFINET device use the slot-oriented format. These assets are bound completely to the PROFINET modules and submodules. Assets that are located outside the PROFINET device use the hierarchical format (LT format) for coding the location of an asset. These assets are localized by their tree level. The tree level begins with Level 0. The value of Level 0 provides information about the proximity to the PROFINET device: ● If the asset is connected to a module that can be addressed through the PROFINET device model, Level 0 has the value 0. The subsequent levels (Level 1 to Level 3) then have the meaning of slot address, subslot address and channel number. If further assets are connected to this asset, the next Level 4 is used. The limit is reached at Level 11. ● If the asset belongs to a PROFINET device but is not connected to a module that can be addressed through the PROFINET device model, Level 0 has a value between 1 and 0x1FF. An example of such an asset is a power supply unit in the PROFINET device. If a further asset is connected to this power supply unit, for example a sensor, the next tree level is used to localize this sensor (Level 1). ● If the asset is located outside the PROFINET device, but, for example, belongs to a machine into which the PROFINET device is installed, Level 0 has a value between 0x200 and 0x3FE. The value 0x3FF for a tree level shows that this tree level is not used. This means that no further asset is connected. In this case, all the lower tree levels down to Level 11 must also have this value. PROFINET with STEP 7 V15 88 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Example AM_Location slot-oriented A rack and the terminal blocks located on it each supply AM data. The slot assignments are shown in the figure. Figure 4-4 Example of assets with slot-oriented AM_Location coding. Code the AM_Location as an asset for each module as follows: Bit 0 – 7: AM_Location.Structure = 0x02 (coding "Slot and SubslotNumber format") Bit 8 – 15: AM_Location.Reserved1 = 0x00 (padding byte) Bit 16 – 31: AM_Location.BeginSlotNumber = 2 (the "Rack" asset begins from Slot 2 on) Bit 32 – 47: AM_Location.BeginSubslotNumber = 0xFFFF (the asset encompasses all the subslots of Slot 2. Otherwise you specify the no. of the subslot at which the asset begins) Bit 48 – 63: AM_Location.EndSlotNumber = 4 (the asset ends at Slot 4) Bit 64 – 79: AM_Location.EndSubslotNumber = 0xFFFF (the asset encompasses all the subslots of Slot 4. Otherwise you specify the no. of the subslot at which the asset ends) Bit 80 – 95: AM_Location.Reserved2 = 0x0000 (padding byte) Bit 96 – 111: AM_Location.Reserved3 = 0x0000 Bit 112 – 127: AM_Location.Reserved4 = 0x0000 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 89 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Example AM_Location level-oriented A complex sensor is connected to an IO module (Slot 5, Subslot 1, Channel 1). Two simple sensors, in turn, are connected to the complex sensor. The module can be addressed within the PROFINET device model. Level 0 therefore has the value 0x0000. The next level (Level 1) is specified by the assigned slot. This is followed by the further levels for the subslot and channel and, if appropriate, further subordinate layers. Figure 4-5 Example of assets with hierarchical AM_Location coding. Detailed coding for the example: Bit 0 – 7: AM_Location.Structure = 0x01 (LT format) Bit 8 – 17: AM_Location.Level0 = 0x000 (assets that are assigned to modules always have the Level 0 value 0x000) Bit 18 – 27: AM_Location.Level1 = 0x005 (Slot 5) Bit 28 – 37: AM_Location.Level2 = 0x001 (Subslot 1) Bit 38 – 47: AM_Location.Level3 = 0x001 (Channel 1) Bit 48 – 57: AM_Location.Level4 = 0x3FF (coding for "Level not used") Bit 58 – 67: AM_Location.Level5 = 0x3FF (coding for "Level not used") ... Bit 118 – 127: AM_Location.Level11 = 0x3FF (coding for "Level not used") Notation used in the screen for the LT coding of complex sensors: 0.5.1.1 The following correspondingly applies for the remaining sensors: LT coding for simple Sensor 1 at complex sensor: 0.5.1.1.1 LT coding for second simple Sensor 2 at complex sensor: 0.5.1.1.2 PROFINET with STEP 7 V15 90 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Asset management data record for I-devices With STEP 7 (TIA Portal) as of V15 and with S7-1500 CPUs as of Firmware V2.5, you have the possibility to compile an asset management record via a user program. Configured as an I-device, these CPUs then supply the data from centrally plugged modules to a requesting IO controller as assets. "S7-1500 CPUs" also refers to the CPU variants S7-1500F, S7-1500T, S7-1500C, S7-1500 SW Controller, S7-1500pro CPUs and ET 200SP CPUs. Asset management records for I-devices I-devices often represent machines. The PROFINET IO controller to which the I-device is assigned only sees the PROFINET interface (also configured as an IO device) and the transfer areas of the I-device configured by the machine manufacturer. The local modules of the I-device are not visible or cannot be accessed. The assigned IO controller can read the central modules as assets of the I-device by means of an asset management record that the user program of the I-device compiles. Figure 4-6 Assets of an I-device Requirement ● S7-1500-CPU as of firmware V2.5, configured as an I-device ● STEP 7 (TIA Portal) as of V15 ● If an IO controller is to read the asset management record: The PROFINET IO controller is programmed correspondingly to read an asset management record. For a SIMATIC IO controller, for example, you call a read instruction (RDREC) with record index 0xF880. The instruction addresses any submodule of the I-device, for example the first configured transfer area submodule. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 91 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Basic procedure The following steps are fundamentally required to create the requirements so that an Idevice can make its local modules available as an asset management record to a requesting IO controller: 1. Make the settings in the properties of the PROFINET interface of the CPU. – Activate "IO device" operating mode – Activate the "Activate asset management using user program" option PROFINET interface forwards a request of an IO controller to the user program of the I-device for reading the asset management record only if the option is selected. Figure 4-7 Activating asset management using a data record 2. Configure the program routine for compiling the asset management record. The program part collects the required I&M0 data of the plugged central modules and stores them in the corresponding fields of the data record structure of the asset management record. 3. Configure the program part for coordinating the data record provision: For this, call the instruction PRVREC (Provide Record) in accordance with the following templates in the corresponding modes: – Cyclic calling (for example in the cycle OB) of the PRVREC instruction with Mode 0, in order to recognize the AMR request. – When the AM record request is recognized, the PRVREC program has to acknowledge within one second that the request has been recognized. This means that PRVREC must be called with the Mode 2, and with the required AM record. If the I-device does not adhere to the time frame, the I-device acknowledges the record request of the IO controller as negative! Particular aspect for configuration of the PRVREC call: PRVREC has to be called with F_ID = 0. This codes that this is an IO-device-specific data record. The SLOT and SUBSLOT output parameters therefore also return the value 0. – Within 10 seconds the AM record now has to be completed and PRVREC be called with Mode 3 (positive response to the IO controller with provision of the AM record). If the I-device does not adhere to the time frame, the I-device acknowledges the record request of the IO controller as negative! A detailed description of the PRVREC instruction and possible error codes for evaluating the function can be found in the online help of STEP 7 (TIA Portal). PROFINET with STEP 7 V15 92 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Compilation of the asset management record You have various possibilities for compiling the asset management record for an I-device: ● Recommendation: The Siemens Industry Online Support makes an application available to you that helps you to compile the asset management record. The data area of the asset management record is divided in two. The first part consists of an automatically determined area that packages the IM0 data of the slots of the I-device into an asset management block. The second part consists of the user-specific asset management blocks. You configure the user-specific asset management blocks based on pre-configured asset management record structures, fill them with information and make them available to the application. The application performs the following: – The application determines the required size of all the asset management blocks. – The application fills the data block in accordance with the specifications of an asset management record with the automatically determined asset management blocks and your user-specific asset management blocks. – The application makes this asset management record available to the higher-level IO controller. The application is described in this application example (https://support.industry.siemens.com/cs/ww/en/view/109748894) ● You create the asset management record yourself. The following section describes how you can compile an asset management record for an I-device yourself. The concept assumes you yourself determine the I&M data for each centrally plugged module and fill the asset management record with this information. The I&M0 data of a module contains basic information about the module such as the manufacturer's code, article number, serial number, hardware and firmware version. These are the data that are also required in the AM record for an asset. Determine the I&M data of centrally plugged modules The central structure consists of an optionally plugged power supply unit (Slot 0), followed by the I-device CPU (Slot 1), and then followed by the further modules, such as digital modules, analog modules, etc. (as of Slot 2). You determine the I&M data with the "Get_IM_Data" instruction for the plugged modules with exception of the CPU: To assign parameters for the "Get_IM_Data" instruction, you require the hardware identifier (LADDR input parameter). You determine the hardware identifier for each occupied slot with the "GEO2LOG" instruction (Determine hardware identifier from slot). Summary of the theoretical steps: 1. In a loop, determine the hardware identifiers of the plugged modules with the "GEO2LOG" instruction. 2. For each hardware identifier found, determine the I&M data by using the "Get_IM_Data" instruction and store these data in a data block that you address with the input parameter DATA. Use ARRAY of BYTE for the data storage. This corresponds to the description of the AM record contents in the preceding section. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 93 Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Forming an AM record with the determined I&M data The following sections are based on the description of the fundamental structure of the AM record, see the preceding section. Since each module of an S7-1500 contains hardware and firmware information, select the coding for "AM_FullInformation" for the assigned BlockType. For the data types used: ● IM_Annotation, IM_OrderID, AM_SoftwareRevision and AM_HardwareRevision: Characters (UTF-8) ● IM_Serial_Number: Characters ("ASCII characters") with the exception of the characters for DEL (0x7F) ● Do not use String data types. They require additional bytes and therefore do not conform to the conventions of the PROFINET standard 61158-6-10 "Application layer protocol specification" Form the AM_FullInformationBlock for each module as follows: Table 4- 2 AM_FullInformationBlock for modules Data record element Description IM_UniqueIdentifier Generate a (pseudo) random UUID (hash value) in accordance with ISO 9834-8 as follows: • Generate an 8-byte hash value across the I&M0 data of the module (as of Slot 2). Use the algorithm Fowler-Noll-Vo (in short: FNV); an algorithm for generating variance coefficients (hash values) across data field, see corresponding example code in the Internet or online support. • Generate an 8-byte hash value across the I&M0 data of the CPU. (Use the algorithm Fowler-Noll-Vo (in short: FNV) as described above) IM_UniqueIdentifier Byte 0 to 7: Hash value of module I&M0 data Bytes 8 to 15: Hash value for CPU-I&M0 data Required customizations to ISO 9834-8: Byte 8, Bit 7 has to be set to 1, and Byte 8, Bit 6 to 0 (result of the AND operator with 0011 1111, subsequent OR operator with 1000 0000) Byte 6, Bit 4 to 7 have to be set to 0100 (result of the AND operation with 0000 1111, then OR operation with 0001 0000) Since this algorithm is based on the I&M0 data of the CPU as well as of the modules, it generates a constant IM_UniqueIdentifier for an individual module. When the configuration changes the IM_UniqueIdentifier also changes. • AM_Location Byte 0 = 0x02 (slot-oriented coding), see description in the preceding section. IM_Annotation Example: "S7-1500 module" and pad the remaining bytes of IM_Annotation with spaces (0x20). IM_OrderID Copy 20 bytes of the I&M0 data of the module (beginning with offset 2 of the I&M0 data). Pad the remaining 44 bytes with spaces (0x20) AM_SoftwareRevision Pad the field with 64 spaces (0x20) AM_HardwareRevision Pad the field with 64 spaces (0x20) IM_Serial_Number Copy 16 bytes of the I&M0 data of the module (beginning with offset 22 of the I&M0 data) IM_Software_Revision Copy 4 bytes of the I&M0 data of the module (beginning with offset 40 of the I&M0 data) PROFINET with STEP 7 V15 94 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.1 Diagnostics mechanisms of PROFINET IO Data record element Description AM_DeviceIdentification Byte 0, 1, 2, 6, 7 = 0x00 Byte 3 = 0x2A (Vendor = Siemens) Byte 4 = 01, Byte 5 = DeviceID (e.g. CPU 15xx = 0x0E) AM_TypeIdentification Copy 2 bytes of the I&M0 data of the module (beginning with offset 48 of the I&M0 data) IM_Hardware_Revision Copy 2 bytes of the I&M0 data of the module (beginning with offset 38 of the I&M0 data) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 95 Diagnostics and maintenance 4.2 Diagnostics using status LEDs 4.2 Diagnostics using status LEDs LEDs for diagnostics on PROFINET Each port of a PROFINET interface of a SIMATIC device has one LED. The following table shows a summary of the meaning of these LEDs in the S7-1500, ET 200MP, ET 200SP and ET 200AL systems. Table 4- 3 S7-1500, ET 200MP, ET 200SP, ET 200AL: LEDs for diagnostics on PROFINET LED image Meaning S7-1500 ET 200MP LINK/TX/RX LED LED off ET 200SP ET 200AL LK LED P1 Link LED P2 Link LED X X X X There is an Ethernet connection between the PROFINET interface of your PROFINET device and a communication partner. X X X X The "LED flashing test" is being performed. X X X X Data is currently being received from or sent to a communications partner on Ethernet via the PROFINET interface of the PROFINET device. X X - - There is no Ethernet connection between the PROFINET interface of the PROFINET device and the communication partner. No data is currently being sent/received via the PROFINET interface. LED green LED flashes green LED flickers yellow Additional information You can find a detailed description of all LEDs of the module with cause of the error and remedies in the relevant documentation for the module. PROFINET with STEP 7 V15 96 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.3 Diagnostics via the display of the S7-1500 CPUs 4.3 Diagnostics via the display of the S7-1500 CPUs Display The S7-1500 CPU has a display and operating keys. The display of the CPU shows you the control and status information in different menus. You use operating keys to navigate through the menus and make a variety of settings in the process. Diagnostics via the display The following indicators can be evaluated for diagnostics purposes on the display: ● Error and alarm texts (system diagnostics, alarm messages) ● Module status for central and distributed modules In the following example of a display of the CPU 1516-3 PN/DP, you can see a warning on the diagnostics icon and an exclamation mark on the icon for module. Figure 4-8 Display of overview PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 97 Diagnostics and maintenance 4.3 Diagnostics via the display of the S7-1500 CPUs Module status To show the module status, navigate on the display through the menu items "Module" > "PROFINET I/O (X1)" > "Station" > "Slot" > "Status" > "Module status". The module status indicates that a fault has occurred in the module. The "lower-level status" is the status of the module in the diagnostics level below this. In the example, the status is "good", i.e., the fault is not in the lower diagnostics level submodule or channel, but instead in the module. Figure 4-9 Display of module status Error and alarm texts You can show diagnostics buffer entries and alarm messages for the relevant automation system on the display. To show the diagnostics buffer entries of the CPU, navigate on the display via the menu items "Diagnostics" > "Diagnostics buffer". Figure 4-10 Display of diagnostics buffer PROFINET with STEP 7 V15 98 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.3 Diagnostics via the display of the S7-1500 CPUs To show the alarm messages of the automation system, navigate through the menu items "Diagnostics" > "Alarms" > "Alarm text" on the display. Note Updating the alarm display The display shows the currently read status of the CPU in static form, the display is not automatically updated. The alarm display is updated after it has been exited and opened again. You set the automatic updating of the diagnostics information under: "Display" > "DiagnosticRefresh". Figure 4-11 Display of alarms Figure 4-12 Display of alarm message Additional information You can find the description of the operation and functions of the display in the SIMATIC S7-1500 Display Simulator (http://www.automation.siemens.com/salesmaterialas/interactive-manuals/getting-started_simatic-s7-1500/disp_tool/start_de.html). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 99 Diagnostics and maintenance 4.4 Diagnostics via Web server 4.4 Diagnostics via Web server The CPUs belonging to the S7 family have their own integrated Web server with a wide range of functions. For diagnostics, the Web server supports you with the following displays: ● Contents of the diagnostic buffer ● Module status ● Actual topology of the PROFINET system ● Set topology of the PROFINET system (from the configuration) Set topology and actual topology - graphic view Requirements for displaying the set and actual topology: ● You have configured the PROFINET ports in the topology editor of the hardware and network editor of STEP 7. ● You have loaded the entire project with STEP 7 in the CPU. The following shows an example of the graphic view. Figure 4-13 Topology - graphic view via the Web server PROFINET with STEP 7 V15 100 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.4 Diagnostics via Web server Meaning of the colored connections in the set/actual topology: Table 4- 4 Meaning of the colored connections in the set/actual topology: Connection Meaning Set topology Actual topology green The current actual connection matches the configured set connection. detected connections red The current actual connection does not match the configured set connection (e.g., port interchanged). - yellow The connection cannot be diagnosed. Causes: - • The communication to an IO device has been disrupted (e.g., cable removed) • Connection to a passive component • Connection to PROFINET devices of another IO controller or PROFINET system ① Configured and accessible PROFINET devices Configured and accessible PROFINET devices are displayed dark-gray. Connections show the ports through which the PROFINET devices of a station are connected. ① Configured but not accessible PROFINET devices The configured but not accessible PROFINET devices are displayed in pink with red border (e.g., device has failed, cable disconnected). ③ Disabled devices All disabled, configured PROFINET devices are displayed light-gray. ④ Interchanged ports Interchanged ports are marked red in the set topology view. The currently connected ports are displayed in the actual topology, the configured set connection in the set topology. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 101 Diagnostics and maintenance 4.4 Diagnostics via Web server ⑤ PROFINET devices of another PROFINET IO system ● In the set topology: A PROFINET device of another PROFINET IO system is displayed with a green connection (or red connected if the ports have been interchanged), when it is directly adjoining a configured and accessible PROFINET device ① and it is also accessible. When the PROFINET device of another PROFINET IO system is not accessible, a yellow connection line is displayed. The connection between two PROFINET devices that both belong to a different PROFINET IO system, cannot be determined and is always displayed in yellow. ● In the actual topology: A PROFINET device of another PROFINET IO system is only displayed if the PROFINET device is in direct proximity to a configured PROFINET device. The PROFINET device is displayed light-gray and with dashed line. For PROFINET devices of a different PROFINET IO system, no status display is shown on the device head. ⑥ Representation of faulty neighbor relations The devices whose neighbor relations cannot be read out completely or correctly are displayed light-gray with red border. Additional information The tabular view of the actual topology and the status overview of the PROFINET devices in the project are possible. You can find these views, additional topology examples, and detailed information on the operation and the functions of the Web server in the Web server (http://support.automation.siemens.com/WW/view/en/59193560) manual. PROFINET with STEP 7 V15 102 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.5 Diagnostics in STEP 7 4.5 Diagnostics in STEP 7 For PROFINET, you have the following options to evaluate diagnostics in STEP 7: ● Online & diagnostics - Devices & networks ● Online & diagnostics - diagnostics of PROFINET ports Online & diagnostics network view In the hardware and network editor (launched from the "Project tree" by double-clicking "Devices & networks"), you can get an overview of the current state of your system by clicking on the "Go online" button. It also shows the configuration information (for example, non-configured modules). This option is also available in the topology view in similar form. Schematic drawing of the network view (online): Figure 4-14 Online & diagnostics network view PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 103 Diagnostics and maintenance 4.5 Diagnostics in STEP 7 Online & diagnostics device view In STEP 7, you can display an overview of the modules in which faults have occurred. To do this, select the menu command "Online > Online & diagnostics". Once you are connected, you can see the status of the accessible devices in the project tree. Double-click the device which displays an alarm message to access the faulty module directly. The device view is opened in the work area. In the device view of the device that reports the fault you can see directly in which module the fault occurs. Open the "Diagnostics" tab and the subordinate "Device information" tab in the Inspector window for a more detailed error description. Schematic drawing of the device view (online): Figure 4-15 Online & diagnostics device view PROFINET with STEP 7 V15 104 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.5 Diagnostics in STEP 7 Diagnostics of PROFINET ports If you select "PROFINET interface > Ports" in the Diagnostics area in the online & diagnostics device view of a PROFINET device, the ports of the PROFINET interface are listed in a table. The table provides you with the following information about the ports of the PROFINET interface. ● Name ● Status ● Settings ● Operating mode Figure 4-16 Diagnostics of PROFINET ports in STEP 7 Additional information You can find information on the system diagnostics for S7-1500, ET 200MP, ET 200SP and ET 200AL in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function manual and online help for STEP 7. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 105 Diagnostics and maintenance 4.6 Extended maintenance concept 4.6 Extended maintenance concept Extended maintenance concept The PROFINET interfaces with integrated switch of the SIMATIC devices support the fourlevel diagnostics concept in accordance with PROFINET specification Version V2.3 or higher with the following status: Table 4- 5 Classification of the diagnostic status Diagnostic status Symbol Good Green checkmark Maintenance Green wrench Severity of the error required Maintenance Yellow wrench demanded Bad Red wrench The aim of the diagnostics concept is the early detection and elimination of potential faults before they cause a production outage. Other status information is defined in addition to the Good (no fault) and Bad (fault) status information for a PROFINET device. The maintenance information is generated with the following system alarms: ● Maintenance required (symbolized by a green wrench) and ● Maintenance demanded (symbolized by a yellow wrench) The times at which the two system alarms are generated can be customized for most wear parameters. PROFINET with STEP 7 V15 106 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.6 Extended maintenance concept Example: Maintenance demanded for a PROFINET cable The following graphic illustrates how diagnostics information is exchanged when the transmission quality on the optical cable decreases due to ageing, for example. In this example, the scenario is considered after a maintenance required has already been diagnosed. Number ① ② ③ ④ ⑤ Description The system reserve of the fiber-optic cable drops below 0 dB. Both the ET 200S PN FO and the switch send the maintenance demanded alarm to the IO controller. Based on the interrupts, the IO controller detects the maintenance demanded from the switch and from the IO device. The module information data is updated in the IO controller and the corresponding error OBs are called. Note: To be able to start the error OBs in the IO controller, the "Call the user program if communication errors occur" property must be selected in STEP 7 for the relevant IO controller. In STEP 7 (on the programming device/PC), the maintenance demanded message is indicated on the IO device and at the switch by a yellow wrench symbol. STEP 7 can also read out detailed information directly from the switch. Figure 4-17 Maintenance demanded for a PROFINET cable PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 107 Diagnostics and maintenance 4.7 Diagnostics of the network topology 4.7 Diagnostics of the network topology Availability As an open standard, you can use any SNMP based systems or software solutions for diagnostics in PROFINET. Network diagnostics The network management protocol SNMP (Simple Network Management Protocol) uses the wireless UDP transport protocol. It consists of two network components, similar to the client/server model. The SNMP manager monitors the network nodes and the SNMP clients collect the various network-specific information in the individual network nodes and store it in a structured form in the MIB (Management Information Base). This information allows a network management system to run detailed network diagnostics. MIB The MIB (Management Information Base) is the database of a device. SNMP clients access this database in the device. The S7 device family supports the following standard MIBs: ● MIB II, standardized in the RFC 1213 ● LLDP-MIB, standardized in the international standard IEC 802.1AB ● LLDP-PNIO-MIB, standardized in the international standard IEC 61158-6-10 Detecting the network topology LLDP (Link Layer Discovery Protocol) is a protocol that is used to detect the closest neighbor. LLDP enables a device to send information about itself and to receive information from its neighbor devices. This information is then saved in the LLDP MIB, for example, and can be queried using SNMP. This information allows a network management system to determine the network topology. Use of SNMP (Simple Network Management Protocol) SNMP can be used as follows: ● By users to integrate network diagnostics into a central HMI/SCADA system using the SIMATIC NET OPC server ● By the IT administration of machine and plant operators to monitor their Industrial Ethernet network using standard network management systems. ● By the IT administration, to monitor the automation network, alongside the office network, using standard network management systems. Use of SNMP in the SIMATIC NET environment SNMP-compliant devices from the SIMATIC NET family can be monitored and operated via a conventional standard Internet browser. The management system known as web-based management offers a wide range of device-specific information (network statistics, status of redundant supply, for example). PROFINET with STEP 7 V15 108 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.8 Diagnostics in the user program 4.8 Diagnostics in the user program 4.8.1 Diagnostics and configuration data records Diagnostics mechanism The IO device outputs a diagnostics interrupt to the IO controller when it detects faults such as wire break on an IO module. This interrupt calls a corresponding organization block in the user program (diagnostics interrupt OB82), in order to generate a defined (programmed) response to the fault and passes a diagnostics data record. Diagnostics data records in PROFINET IO There are two different types of diagnostics data record: 1. Channel diagnostics data records Channel diagnostics data records are generated if a channel is in an error state and / or has triggered an interrupt. A diagnostics data record of length 0 is returned if there is no fault. 2. Vendor-specific diagnostics data records The structure and size of vendor-specific diagnostics data records depend on the vendor's settings. For information about vendor-specific diagnostics data records, refer to the appropriate device manual. Addressing levels of diagnostics data records Diagnostics and configuration data is evaluated at the following addressing levels: ● Device level ● AR (Application Relation) ● API (Application Process Identifier) ● Slot ● Subslot PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 109 Diagnostics and maintenance 4.8 Diagnostics in the user program A group of diagnostics and configuration data records are available for each address level (exception: device level always 0xF80c). In HEX representation, the individual groups of data records are distinguished by the first letter of the data record number. Figure 4-18 Addressing levels of diagnostics data records The information for each IO device (addressing level AR), module (addressing level slot) or submodule (addressing level subslot) is always transferred in separate diagnostics or configuration data records. The data record returns diagnostics data or configuration data for one or more subslots, slots and APIs, depending on the addressing level. Note The diagnostics information is only generated for configured modules / submodules / channels. PROFINET with STEP 7 V15 110 Function Manual, 12/2017, A5E03444486-AH Diagnostics and maintenance 4.8 Diagnostics in the user program 4.8.2 Evaluate diagnostics in the user program Diagnostics in the user program For PROFINET IO, a cross-vendor structure of data records with diagnostics information applies. Diagnostics information is created only for channels on which a fault has occurred. With PROFINET, there are two basic ways to obtain diagnostics information. 1. Evaluating the diagnostics status Read out the diagnostics of your PROFINET IO system using the instructions "DeviceStates" and "ModuleStates", to localize those stations / modules or station / modules with maintenance demanded or maintenance required that have faults within a PROFINET IO system. The instruction RDREC (read data record) is then used to read various diagnostics data records directly from the module concerned and thus obtain detailed information about the error. Number ① ② Description All individual errors are collected in a single data record on the interface module. In your user program, the instruction "RDREC" reads the entire station status asynchronously directly from the IO device. Figure 4-19 Example: Evaluating diagnostics data records with the instruction "RDREC" PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 111 Diagnostics and maintenance 4.8 Diagnostics in the user program 2. Evaluation of interrupts When the error OB (OB 82) is called, the OB's start information provides you with information on the cause and location of the error. Detailed information on the error event can be obtained in the error OB using the instruction "RALRM" (read additional interrupt information). Number ① ② ③ Description Every error is sent to the IO controller individually as channel diagnostics information in the form of an interrupt. In the IO controller, the module status data is updated automatically and the error OB (OB 82) is started. In your user program in the error OB (OB 82), the instruction "RALRM" reads the error synchronously from the IO controller without addressing the IO device. Figure 4-20 Diagnostics with OB 82 and the instruction "RALRM" Instructions and OBs You will find information on the instructions and OBs in the STEP 7 online help. PROFINET with STEP 7 V15 112 Function Manual, 12/2017, A5E03444486-AH Functions 5 Introduction The following section describes the PROFINET IO functions for field of application, properties and configuration in STEP 7. Refer to the documentation for the respective device to see to what extent the PROFINET devices support the described functions. You can find a tabular overview of the PROFINET devices and the functions these support on the Internet (https://support.industry.siemens.com/cs/ww/en/view/102325771). 5.1 Connecting other bus systems 5.1.1 Connecting other bus systems Fieldbus integration PROFINET allows you to use a proxy-capable PROFINET device to integrate existing fieldbus systems (for example, PROFIBUS, AS interface). The devices of these fieldbus systems are mapped on proxy PROFINET devices. In this way, you can set up any hybrid systems consisting of fieldbus and Ethernet-based subsystems. This allows a continuous exchange of information. Figure 5-1 Gateways on PROFINET IO PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 113 Functions 5.1 Connecting other bus systems Gateways of an S7-1500 CPU An overview of the gateways at an S7-1500 CPU is provided in this FAQ (https://support.industry.siemens.com/cs/ww/en/view/88778900). Connecting to building busses ● BACnet: You can find an application example for configuring communication between a SIMATIC PLC and a BACnet network with a gateway here:Application example (https://support.industry.siemens.com/cs/ww/en/view/109476182). ● M-bus: You can find an application example for configuring communication between a SIMATIC PLC and an M-bus network with a gateway here:Application example (https://support.industry.siemens.com/cs/ww/en/view/109478527). ● DALI: You can find an application example for configuring communication between a SIMATIC PLC and a DALI network with a gateway here:Application example (https://support.industry.siemens.com/cs/ww/en/view/109740160). ● KNX: You can find an application example for configuring communication between a SIMATIC PLC and a KNX network with a gateway here:Application example (https://support.industry.siemens.com/cs/ww/en/view/109739689). PROFINET with STEP 7 V15 114 Function Manual, 12/2017, A5E03444486-AH Functions 5.1 Connecting other bus systems 5.1.2 Linking PROFINET and PROFIBUS Linking PROFINET and PROFIBUS With a proxy-capable PROFINET device which is equipped with a PROFINET interface in addition to a PROFIBUS interface (for example, IE/PB Link PN IO), you can integrate existing PROFIBUS configurations into the PROFINET configuration. The following figures shows how a PROFIBUS system is connected via IE/PB Link to a CPU S7-1500 (as of firmware version 1.7). Figure 5-2 Gateway from PROFINET and PROFIBUS via IE/PB link PROFINET device with proxy functionality The PROFINET device with proxy functionality is the substitute for a PROFIBUS device on Ethernet. The proxy functionality allows a PROFIBUS device to communicate not only with its master but also with all devices on PROFINET. With PROFINET you can connect an existing PROFIBUS system to an IO controller, for example with the help of an IE/PB Link PN IO. From the IO controller perspective, the PROFIBUS DP slaves are connected to the same network as the IE/PB Link PN IO. These slaves have the same device name and IP address as the IE/PB Link PN IO, but different device numbers. Furthermore, each also has a specific PROFIBUS address. In this way, you can link both DPV0 and DPV1 slaves to PROFINET. For information on how to connect a DP slave to a PROFINET IO system, refer to section Connect the DP slave via the IE/PB Link to a PROFINET IO system (Page 116). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 115 Functions 5.1 Connecting other bus systems Diagnostic options with a CPU S7-1500 as IO controller The CPU S7-1500 (as of firmware version 1.7) as IO controller detects disrupted DP slaves behind the IP/PB link. 5.1.3 Connect the DP slave via the IE/PB Link to a PROFINET IO system Requirements ● STEP 7 as of V13 SP1 ● S7-1500 CPU as of firmware version 1.7 ● ET 200SP CPU as of firmware version 1.7 ● CPU 1516pro-2 PN as of firmware version 2.0 ● S7-1500 Software Controller as of firmware version 1.7 ● S7-300/400 CPU Procedure for connecting a DP slave via an IE/PB Link To connect a DP slave to a PROFINET IO system via an IE/PB Link in STEP 7, follow these steps: 1. Drag-and-drop a PROFINET CPU, for example CPU 1513-1 PN, from the hardware catalog into the network view of STEP 7. 2. Drag-and-drop an IE/PB Link PN IO from the hardware catalog into the network view of STEP 7. The IE/PB Link PN IO is located under Network components > Gateways > IE/PB Link PN IO. 3. Assign the IE/PB Link PN IO to the CPU. 4. Drag a PROFIBUS interface module e.g. IM155-6 DP HF, from the hardware catalog to the network view. 5. Assign the interface module to the IE/PB Link. Figure 5-3 Configuring an IE/PB link 6. Select the IE/PB Link PN IO in the network view of STEP 7. PROFINET with STEP 7 V15 116 Function Manual, 12/2017, A5E03444486-AH Functions 5.1 Connecting other bus systems 7. In the Inspector window, go to the "Gateway" area and select the "Network gateway as PROFINET IO proxy" option. Figure 5-4 Setting a gateway 8. In the PROFINET device number area, you can assign a PROFINET device number for the DP slave. If you have selected the "Device number = PB address" check box (default), STEP 7 automatically assigns the device number according to the PROFIBUS address of the slave. In addition, you no longer need to update the device number if the PROFIBUS address changes. Figure 5-5 Assigning PN device numbers for IE/PB link Result You have connected the DP slave to the PROFINET IO system. Reference Additional information on the IE/PB link is available in the manual Gateway IE/PB Link PN IO (http://support.automation.siemens.com/WW/view/en/19299692). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 117 Functions 5.2 Intelligent IO devices (I-devices) 5.2 Intelligent IO devices (I-devices) 5.2.1 I-device functionality I-device functionality The "I-device" (intelligent IO device) functionality of a CPU facilitates data exchange with an IO controller and operation of the CPU as intelligent preprocessing unit of sub processes, for example. The I-device is linked as an IO device to a "higher-level" IO controller. The preprocessing is handled by the user program in the I-device. The process values acquired in the centralized or distributed (PROFINET IO or PROFIBUS DP) I/O are preprocessed by the user program and made available to the IO controller. Figure 5-6 I-device "I-device" naming conventions In the remainder of this description, a CPU or a CP with I-device functionality is simply called an "I-device". Application example: Configuration and application of the PROFINET I-device function A detailed application example is available here (https://support.industry.siemens.com/cs/ww/en/view/109478798). PROFINET with STEP 7 V15 118 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) 5.2.2 Properties and Advantages of the I-Device Fields of application Fields of application of the I-device: ● Distributed processing A complex automation task can be divided into smaller units/subprocesses. This results in manageable processes which lead to simplified subtasks. ● Separating subprocesses Complicated, widely distributed and extensive processes can be subdivided into several subprocesses with manageable interfaces by using I-devices. These subprocesses can be stored in individual STEP 7 projects if necessary, which can later be merged to form one master project. ● Know-how protection Components can only be delivered with a GSD file for the I-device interface description instead of with a STEP 7 project. The know-how of the user program may no longer be published. Properties Properties of the I-device: ● Unlinking STEP 7 projects Creators and users of an I-device can have completely separated STEP 7 automation projects. The GSD file forms the interface between the STEP 7 projects. This allows a link to standard IO controllers via a standardized interface. ● Real-time communication The I-device is provided with a deterministic PROFINET IO system via a PROFINET IO interface and therefore supports RT (real-time communication) and IRT (isochronous real time). Advantages The I-device has the following advantages: ● Simple linking of IO controllers ● Real-time communication between IO controllers ● Relieving the IO controller by distributing the computing capacity to I-devices. ● Lower communication load by processing process data locally. ● Manageable, due to processing of subtasks in separate STEP 7 projects PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 119 Functions 5.2 Intelligent IO devices (I-devices) 5.2.3 Characteristics of an I-Device Principle An I-device is included in an IO system like a standard IO device. I-device without lower-level PROFINET IO system The I-device does not have its own distributed I/O. The configuration and parameter assignment of the I-devices in the role of an IO device is the same as for a distributed I/O system (for example ET 200). Figure 5-7 I-device without lower-level PROFINET IO system I-device with lower-level PROFINET IO system Depending on the configuration, an I-device can also be an IO controller on a PROFINET interface in addition to having the role of an IO device. This means that the I-device can be part of a higher-level IO system via its PROFINET interface and as an IO controller can support its own lower-level IO system. The lower-level IO system can, in turn, contain I-devices (see figure below). This makes hierarchically structured IO systems possible. PROFINET with STEP 7 V15 120 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) In addition to its role as IO controller, an I-device can also be used via a PROFIBUS interface as DP master for a lower-level PROFIBUS system. Figure 5-8 I-device with lower-level IO system PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 121 Functions 5.2 Intelligent IO devices (I-devices) Example - the I-device as IO device and IO controller The I-device as IO device and IO controller is explained based on the example of a print process. The I-device controls a unit (a subprocess). One unit is used, for example, to insert additional sheets such as flyers or brochures in a package of printed material. Figure 5-9 Example - the I-device as IO device and IO controller Unit 1 and unit 2 each consist of an I-device with centralized I/O. The I-device along with the distributed I/O system (for example ET 200) forms unit 3. The user program on the I-device is responsible for preprocessing the process data. For this task, the user program of the I-device requires default settings (for example control data) from the higher-level IO controller. The I-device provides the higher-level IO controller with the results (for example status of its subtask). PROFINET with STEP 7 V15 122 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) I-device as a shared device An I-device can also be used simultaneously by multiple IO controllers as a shared device. Figure 5-10 I-device as a shared device Information about configuring an I-device as a shared device is available in the section Configuring an I-device as a shared device (Page 145). 5.2.4 Data Exchange between higher- and lower-level IO system Introduction The next chapter shows the data exchange between the higher- and lower-level IO system. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 123 Functions 5.2 Intelligent IO devices (I-devices) Transfer areas Transfer areas are an interface to the user program of the I-device CPU. Inputs are processed in the user program and outputs are the result of the processing in the user program. The data for communication between IO controller and I-device is made available in the transfer areas. A transfer area contains an information unit that is exchanged consistently between IO controller and I-device. You can find more information on configuration and use of transfer areas in the section Configuring the I-device (Page 125). The next figure shows the data exchange between the higher- and lower-level IO system. The individual communication relations are explained below based on the numbers. Figure 5-11 Data exchange between higher- and lower-level IO system PROFINET with STEP 7 V15 124 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) ① Data exchange between higher-level IO controller and normal IO-device In this way, the IO controller and IO devices exchange data through PROFINET. ② Data exchange between higher-level IO controller and I-device In this way, the IO controller and the I-device exchange data through PROFINET. The data exchange between a higher-level IO controller and an I-device is based on the conventional IO controller / IO device relationship. For the higher-level IO controller, the transfer areas of the I-devices represent submodules of a preconfigured station. The output data of the IO controller is the input data of the I-device. Analogously, the input data of the IO controller is the output data of the I-device. ③ Transfer relationship between the user program and the transfer area In this way, the user program and the transfer area exchange input and output data. ④ Data exchange between the user program and the I/O of the I-device In this way, the user program and the centralized / distributed I/O exchange input and output data. ⑤ Data exchange between the I-device and a lower-level IO device In this way, the I-device and its IO devices exchange data. The data transfer is via PROFINET. 5.2.5 Configuring the I-device Introduction There are basically two possibilities for configuration: ● Configuration of an I-device within a project ● Configuration of an I-device that is used in another project or in another engineering system. STEP 7 allows you to configure an I-device for another project or for another engineering system by exporting a configured I-device to a GSD file. You import the GSD file in other projects or engineering systems as with other GSD files. The transfer areas for the data exchange, among other data, are stored in this GSD file. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 125 Functions 5.2 Intelligent IO devices (I-devices) Configuration of an I-device within a project 1. Drag-and-drop a PROFINET CPU from the hardware catalog into the network view. 2. Drag-and-drop a PROFINET CPU, which can also be configured as an IO device, from the hardware catalog into the network view. This device is configured as I-device (e.g., CPU 1516-3 PN/DP). 3. Select the PROFINET interface for the I-device. 4. In the Inspector window in the area navigation choose "Operating mode" and select the check box "IO device". 5. Now you have the option of choosing the IO controller in the "Assigned IO controller" drop-down list. Once you have chosen the IO controller, the networking and the IO system between both devices are displayed in the network view. Figure 5-12 Configuring the I-device 6. With the "Parameter assignment of PN interface by higher-level IO controller" check box, you specify whether the interface parameters will be assigned by the I-device itself or by a higher-level IO controller. If you operate the I-device with a lower-level IO system, then the parameters of the Idevice PROFINET interface (for example, port parameter) cannot be assigned with the higher-level IO controller. PROFINET with STEP 7 V15 126 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) 7. Configure the transfer areas. The transfer areas are found in the area navigation section "I-device communication". – Click in the first field of the "Transfer area" column. STEP 7 assigns a default name which you can change. – Select the type of communication relation: you can currently only select CD or F-CD for "Controller-device communication relation". – Addresses are automatically preset; you can correct addresses if necessary, and determine the length of the transfer area which is to be consistently transferred. Figure 5-13 Configuring the transfer areas 8. A separate entry is created in the area navigation for each transfer area. If you select one of these entries, you can adjust the details of the transfer area, or correct them and comment on them. Configuring an I-device with a GSD file If you use an I-device in another project, or if the I-device is used in another engineering system, then configure the higher-level IO controller and the I-device as described above. However, click on the "Export" button after configuring the transfer areas so a new GSD file is created from the I-device. This GSD file represents the configured I-device in other projects. The "Export" button is found in the "I-device communication" section of the Inspector window. The hardware configuration is compiled and the export dialog opened. Assign a name for the I-device proxy as well as a description in the fields provided. Click the "Export" button to complete your process. Finally, import the GSD file, for example, in another project. 5.2.6 Program examples Introduction This simple program example shows how you use the transfer areas of an I-device. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 127 Functions 5.2 Intelligent IO devices (I-devices) Requirements You have configured an I-device. Task The result of an "AND logic operation" of two inputs (preprocessing) in the I-device is to be provided to the higher-level IO controller. This result is to be assigned to a local output in the IO master (further processing). Use a transfer area with the following addresses for this purpose: ● Address in the I-device: Q568 ● Address in the IO controller: I68 Required steps The following steps to solve the task: 1. Configuring the transfer area 2. Programming I-device 3. Programming IO controller Configuring the transfer area Configure a transfer area with the following properties in the I-device: Figure 5-14 I-device transfer area, sample program PROFINET with STEP 7 V15 128 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) Programming I-device To program the sample program for the I-device, follow these steps: 1. Using the SCL programming language, create a new function with the name "preprocessing" in the project tree in "Program blocks" > "Add new block". Open the function. 2. In the interface of the function "preprocessing", create the following tags: Name Data type Input / output type input 1 bool Input input 2 bool Input result bool Output 3. In the instruction window of the function "preprocessing", write the following program code: #result:=#input 1input 2; 4. Call the function "preprocessing" in a program cycle OB, for example, in OB1. 5. Wire the function "preprocessing" in the program cycle OB as follows: Figure 5-15 I-device sample program Programming IO controller To program the sample program for the IO controller, follow these steps: 1. Using the SCL programming language, create a new function with the name "further processing" in the project tree in "Program blocks" > "Add new block". Open the function. 2. In the interface of the function "further processing", create the following tags: Name Data type Input / output type result bool Input output bool Output 3. In the instruction window of the function "further processing", write the following program code: #output:=#result; PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 129 Functions 5.2 Intelligent IO devices (I-devices) 4. Call the function "further processing" in a program cycle OB, for example, in OB1. 5. Wire the function "further processing" in the program cycle OB as follows: Figure 5-16 IO controller sample program Result The IO controller and the I-device can exchange data with each other through the input/output transfer areas. 5.2.7 Diagnostics and interrupt characteristics Diagnostics and interrupt characteristics S7 CPUs have numerous diagnostics and interrupt functions that can, for example, report errors or failures of lower-level IO systems. These diagnostics messages reduce down times and simplify localization and elimination of problems. Diagnostics options in the higher-level IO controller and in the I-device The following diagnostics functions are available to the higher-level IO controller and the Idevice CPU: ● OB 83 (pull/plug) ● OB 86 (rack failure) ● OB 122 (I/O access error) Note The diagnostics messages of the I/O can be processed in the user program of the Idevice CPU and passed on from there to the higher-level IO controller via transfer areas. PROFINET with STEP 7 V15 130 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) Operating state changes and station failure / station return In the following table, you can see which consequences an operating state change or the failure of an IO controller / I-device of the SIMATIC family has on the respective other(s): Table 5- 1 Operating state changes and station failure / station return Initial status Event I-device response Higher-level IO controller I-device CPU is in RUN, higherlevel IO controller is in RUN The I-device CPU changes to STOP - During the updating of the process image with the instructions "UPDAT_PI" and "UPDAT_PO" an error report is returned at the parameter RET_VAL. With direct IO access to all transfer areas to the I-device: depending on the type of error handling, e.g., call of OB 122 (IO access error). I-device CPU is in STOP higherlevel IO controller is in RUN The I-device CPU is starting up Call of OB 100 (startup). Call of OB 83 (pull/plug) for input transfer areas to the higher-level IO controller. Until call of OB 83 in the case of direct access to the input transfer areas to the higher-level IO controller: depending on the type of error handling, e.g., call of OB 122 (IO access error). I-device CPU is in RUN, higherlevel IO controller is in RUN The higher-level IO controller changes to STOP During the updating of the process image with the instructions "UPDAT_PI" and "UPDAT_PO" an error report is returned at the parameter RET_VAL. Call of OB 83 (pull/plug) for all transfer areas to the I-device. Until call of OB 83 in the case of direct access to the transfer areas to the Idevice: depending on the type of error handling, e.g., call of OB 122 (IO access error). - With direct IO access to the input transfer areas to the higher-level IO controller: depending on the type of error handling, e.g., call of OB 122 (IO access error). Note: Output transfer areas can still be accessed. Higher-level IO controller is in STOP, I-device CPU in RUN The higher-level IO controller starts up Call of OB 83 (pull/plug) for input transfer areas to the higher-level IO controller. Call of OB 100 (startup). Until call of OB 83 in the case of direct access to the input transfer areas to the higher-level IO controller: depending on the type of error handling, e.g., call of OB 122 (IO access error). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 131 Functions 5.2 Intelligent IO devices (I-devices) Initial status Event I-device response Higher-level IO controller I-device CPU is in RUN, higherlevel IO controller is in RUN Station failure Idevice, for example, through bus interruption If the I-device continues to run without a bus connection: Call of OB 86 (rack failure). Call of OB 86 (rack failure). During the updating of the process image with the instructions "UPDAT_PI" and "UPDAT_PO" an error report is returned at the parameter RET_VAL. With direct IO access to all transfer areas to the higher-level IO controller: depending on the type of error handling, e.g., call of OB 122 (IO access error). I-device CPU is in RUN, higherlevel IO controller is in RUN, communication connection between IO controller and Idevice is interrupted (bus interruption). The bus connection between the IO controller and Idevice has been reestablished and the I-device is again included in the user data traffic. During the updating of the process image with the instructions "UPDAT_PI" and "UPDAT_PO" an error report is returned at the parameter RET_VAL. With direct IO access to all transfer areas to the I-device: depending on the type of error handling, e.g., call of OB 122 (IO access error). Call of OB 86 (rack failure). Call of OB 86 (rack failure). Call of OB 83 (pull/plug) for input transfer areas to the higher-level IO controller. Until reporting of station re-integration by OB 86 with direct IO access to all transfer areas to the I-device: depending on the type of error handling, e.g., call of OB 122 (IO access error) Until call of OB 83 in the case of direct access to the input transfer areas to the higher-level IO controller: depending on the type of error handling, e.g., call of OB 122 (IO access error). Note Special characteristic during startup of the higher-level IO controller In contrast to the station return message from IO devices in the IO controller, which are covered completely by the call of the OB 86, the station return message of a higher-level IO controller in the I-device is separated into 2 parts: 1. Call of the OB 86: The initial values for the outputs of the I-device are set. However, the input values are not yet valid. These values will first be valid with the opening of OB 86 in the higher-level IO controller. 2. Call of OB 83 for each input transfer area; with this call, the validity of an input transfer area is displayed. The starting up of the I device is first complete when the OB 83 has been called for the input transfer areas. This step can be delayed or not occur at all in the following situations: – Higher-level IO controller is in STOP: OB 83 is first called at the STOP-RUN transition of the higher-level IO controller. – The IRT communication has been disrupted (sync-master failure, topology error, ...). OB 83 is opened only after the IRT communication has taken place. Reference For more information on error handling in the case of direct I/O access, refer to "Error handling" in the STEP 7 online help. PROFINET with STEP 7 V15 132 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) 5.2.8 Rules for the Topology of a PROFINET IO System with I-Device Introduction The following recommendations for the structure and configuration of an IO system when using I-devices will help you to keep the bandwidths required for keeping communication small. The following communication paths should not overlap: ● Communication paths between the IO controller and the IO device of its IO system. ● Communication paths of the I-device CPU and the IO devices of your IO system. I-device with one port Connect an I-device with only one port to a PROFINET switch that is uncoupled from the higher-level IO system. Connect the lower-level IO system to another port of the switch as shown in the following figure. Figure 5-17 I-device with one port PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 133 Functions 5.2 Intelligent IO devices (I-devices) I-device with two ports With an I-device with two ports, connect one port, uncoupled from the higher-level IO system, to the port of the PROFINET switch. Use the second port for the lower-level IO system as shown in the following figure. Figure 5-18 I-device with two ports PROFINET with STEP 7 V15 134 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) I-device with three or more ports If you have an I-device with three or more ports, connect the I-device to one or both ports to the higher-level IO system in a linear bus topology. Connect the third port to the lower-level IO system uncoupled from the linear bus topology as shown in the following figure. Figure 5-19 5.2.9 I-device with three or more ports Boundary conditions when using I-devices Note the following boundary conditions when using I-devices: Bandwidth The number of addresses of the configured transfer areas affects the usable bandwidth of the I-device: ● Bandwidth of the transfer areas + bandwidth of the lower-level IO system = total bandwidth used on the I-device If the address space of the transfer areas is too large, this indicates a larger bandwidth requirement and can thus lead to longer update times. Tip: Keep the address space of the transfer area as small as possible. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 135 Functions 5.2 Intelligent IO devices (I-devices) Rules for RT and IRT communication. IO systems with I-devices are also suitable for setting up real-time applications with RT and IRT communication. The following rules must be followed for this: ● Both the higher-level and the lower-level IO system support RT communication. You can use RT communication for both IO systems at the same time. ● IRT communication can be combined with RT communication. You can use IRT communication in one of the two IO systems. Use IRT either in a higher-level or in a lower-level IO system. 5.2.10 Configuring PROFIenergy with I-devices The requirement for program-controlled pauses for saving energy with PROFINET devices is that the PROFINET devices support the PROFIenergy protocol. Only if a PROFINET device (I/O device) supports the PROFIenergy protocol does an I/O controller actually send PE commands to this I/O device, for example to start or stop pauses. If an I/O device supports the PROFIenergy protocol, this property is saved in its PROFINET GSD file and is available for configuration in an engineering system. For S7-1500 CPUs as intelligent I/O devices (I-devices), you have the option with STEP 7 V13 service pack 1 or later to set PROFIenergy support for each transfer area. If you have selected the "Enable PROFIenergy communication" option for a transfer area and import the generated PROFINET GSD file into another project, you can handle an Idevice as a PE entity there. Requirements ● STEP 7 as of V13 service pack 1 ● CPU supports PROFIenergy with I-devices, for example CPU 1215C DC/DC/DC as of firmware version 4.2 ● You use the PROFINET IO interface as an I-device and have created transfer areas. ● The user program in the I-device handles PROFIenergy commands Background: You need to program PROFIenergy functions with I-devices in the user program using the "PE_I_DEV" instruction and corresponding auxiliary blocks; this is different compared with IO devices for which this functionality is made available by the firmware. You may therefore only activate the PROFIenergy support for transfer areas if the user program in the I-device is configured correspondingly as well. PROFINET with STEP 7 V15 136 Function Manual, 12/2017, A5E03444486-AH Functions 5.2 Intelligent IO devices (I-devices) Enabling PROFIenergy for transfer areas of I-devices Proceed as follows to assign parameters for the support of PROFIenergy: 1. Select the PROFINET interface (X1) of the CPU. 2. Select the required transfer area in the area navigation, for example: Operating mode > I-device communication > Transfer_area_1. 3. Select the check box "Enable PROFIenergy communication". Figure 5-20 Configuring PROFIenergy with I-devices Once the I-device is fully configured, generate the GSD file for the I-device and import this file in the project for the I/O controller. The GSD file generated contains an entry that specifies that the I-device supports the PROFIenergy profile. To address the I-device, for example for the PE command "PE_START_END", use the hardware identifier of the "PROFIenergy supporting" transfer area in the I-device. To address the IO controller for the PE command "PE_I_DEV", use the hardware identifier of the transfer area that is supplied with the data for PROFIenergy on the IO controller. You can find more information on PROFIenergy in the sectoin Saving energy with PROFIenergy (Page 243). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 137 Functions 5.3 Shared device 5.3 Shared device 5.3.1 Useful information on shared devices shared device functionality Numerous IO controllers are often used in larger or widely distributed systems. Without the "Shared Device" function, each I/O module of an IO device is assigned to the same IO controller. If sensors that are physically close to each other must provide data to different IO controllers, several IO devices are required. The "Shared Device" function allows the modules or submodules of an IO device to be divided up among different IO controllers. Thus allowing flexible automation concepts. You have, for example, the possibility of combining I/O modules lying near other into an IO device. ① ② PROFINET Logical assignment Figure 5-21 Example: Shared device with 2 IO controllers PROFINET with STEP 7 V15 138 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device Principle Access to the submodules of the shared device is then divided up among the individual IO controllers. Each submodule of the shared device is assigned exclusively to one IO controller. Requirements ● STEP 7 V12 Service Pack 1 or higher ● IO device supports the shared device function, e.g. interface module IM 155-5 PN ST ● IO controller supports the shared device function, for example CPU 1516-3 PN/DP as of firmware version 1.1 or CPU 1215 DC/DC/DC as of firmware version 4.1 Explanatory notes: ● A CPU that is configured as an I-device can be used as a shared device. For this purpose, you create a GSD file for the I-device in STEP 7 via "GSD export". You then import the GSD file into a different project and assign the I-device to the IO controller there. The CPU has to support the GSD export, for example CPU 1215C DC/DC/DC as of firmware version 4.1. The maximum number of IO controllers that you can assign to a CPU configured as a shared I-device is given in the technical specifications in the CPU manuals. Configuring the access The IO device must be present in several projects so that the modules or submodules of an IO device can be assigned to different IO controllers. A separate project is required for each IO controller. You use the "Shared device" parameter of the interface module to determine the modules or submodules to which the IO controller has access: ● If the local IO controller has access to the configured module, select the name of the IO controller from the list. ● If the IO controller from a different project and not the local IO controller is to have access to the configured module, select the entry "---". The configuration is consistent regarding access if each module or submodule in exactly one project is assigned to an IO controller. Module or submodule is assigned to another IO controller The paragraph below describes the consequences of the "---" setting of the "Shared device" parameter from the point of view of the local IO controller. In this case, the local IO controller does not have access to the module configured in this way. Specifically, this means: ● No data exchange with the module or submodule ● No reception of alarms or diagnostics, which means no display of the diagnostics status in the online view ● No parameter assignment of the module or submodule PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 139 Functions 5.3 Shared device Setting of the real-time properties STEP 7 calculates the communication load and thus the resulting update times. You must enter the number of project-external IO controllers in the project in which the PROFINET interface of the shared device is assigned to the IO controller so that a calculation is possible with shared device configurations. The maximum possible number of IO controllers for the shared device depends on the device. This number is stored in the GSD file of the shared device. You can set a very short send clock with a CPU as IO controller. The send clock can be shorter than the shortest send clock supported by the shared device. In this case, the shared device is operated by the IO controller with a send clock that it supports (send clock adaptation). Example: A CPU supports send clocks starting from 0.25 ms. A configured IO device also supports send clocks starting at 0.25 ms; another IO device supports send clocks starting at 1 ms. In this case, you have the option of setting the short send clock of 0.25 ms for the CPU. The CPU operates the "slow" IO device with the send clock of 1 ms, for example. Rules for the configuration ● IO controllers that use the shared device are created in different projects. In each project, care must be taken that the shared device is configured identically in each station. Only one IO controller may ever have full access to a submodule. Inconsistencies in the configuration result in a failure of the shared device. ● If you have selected the "Use router" option for the IO controllers in use, you need to set the same router address in all the IO controllers involved. ● I/O addresses of a module or submodule can only be edited if a module or submodule is assigned to the IO controller in the same project. ● The shared device must have the same IP parameters and the same device name in each project. ● The send clock must be identical for all IO controllers that have access to the shared device. ● The S7 subnet ID of the subnet to which the shared device is connected must be identical in all projects. ● The following functions are only available if the PROFINET interface of the shared device is assigned to the local IO controller: – IRT operation – Prioritized startup – Parameter assignment of the port properties PROFINET with STEP 7 V15 140 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device Boundary conditions The following boundary conditions result because a shared device configuration is distributed across several projects: ● The addresses of modules or submodules that are not assigned to this IO controller are missing in the address overview of each IO controller that has access to a shared device. ● The modules or submodules that are not assigned are not taken into consideration in the configuration limit calculation for the shared device during the consistency check. For this reason, you must verify for yourself that the maximum number of submodules or the maximum amount of cyclic IO data for the shared device will not be exceeded. For information on the maximum quantities, refer to the documentation for the devices you are using. ● Configuration errors such as the assignment of a module or submodule to several IO controllers are not detected in STEP 7. ● CPUs that are loaded with a shared device configuration do not have any information on whether the IO device is a shared device. Modules or submodules that are assigned to other IO controllers and therefore other CPUs are missing in the loaded configuration. These modules or submodules are therefore displayed neither in the CPU web server nor in the CPU display. Response in the event of fault Information about how PROFINET IO controllers behave in the event of a fault when accessing the data of a shared device is available in this FAQ (https://support.industry.siemens.com/cs/ww/en/view/109572804). 5.3.2 Configuring shared device Below, you will find a description of how to configure a distributed I/O system as a shared device with STEP 7 V12, Service Pack 1 or higher. A "distributed" configuration with different engineering tools for different IO controller families is always possible. However, the description of the procedure is based solely on STEP 7 as of V12, service pack 1. The description is limited to two IO controllers of the S7-1500 family that share a shared device. Two projects are created (Shared-Device-1 and Shared-Device-2), each with one IO controller (PLC1 and PLC2). You must create the shared device in both projects, even though it is physically one and the same IO device. Requirements ● STEP 7 V12 Service Pack 1 or higher ● The IO controller supports the shared device function, for example CPU 1513-1 PN as of firmware version 1.1. ● IO device supports shared device functionality, for example interface module IM 155-5 PN ST as of firmware version 2.0. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 141 Functions 5.3 Shared device Procedure - Creating project 1 To create the first project with a shared device, follow these steps: 1. Start STEP 7. 2. Create a new project with the name "Shared-Device-1". 3. Insert, for example, a CPU 1513-1 PN from the hardware catalog in the network view. Name it "PLC1". 4. Insert an IO device with the "Shared device" function from the hardware catalog. 5. Assign the IO controller "PLC1" to the IO device. 6. Double-click the IO device and insert all required modules and submodules from the hardware catalog in the device overview table. 7. Assign the module parameters. 8. Save the project. Procedure - Creating project 2 To create the second project with a shared device, follow these steps: 1. Start STEP 7 once again. A new instance of STEP 7 opens. 2. In the new instance, create a new project with the name "Shared-Device-2". 3. Insert, for example, a CPU 1513-1 PN in the network view. Name it "PLC2". 4. Copy the IO device from the project "Shared-Device-1" and insert it in the network view of project "Shared-Device-2". 5. Assign the IO controller "PLC2" to the IO device. 6. Save the project. Both projects now have an identically structured IO device that must be configured in the next step for the different types of IO controller access. Procedure - Configuring access to the shared device The modules and submodules you insert in the shared device are automatically assigned to the local CPU. To change the assignment, follow these steps: 1. Select the interface module in the network view or device view of project "Shared-Device1". 2. Select the "Shared Device" area in the Inspector window. A table shows which CPU has access to the respective module or submodule for all configured modules. The default setting is that the local CPU has access to all modules and submodules. PROFINET with STEP 7 V15 142 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device 3. Keep the "PLC1" setting for all modules and submodules that are to remain in the address range of the local CPU. Select the setting "---" for all modules and submodules that are to be located in the address range of the CPU from the "Shared-Device-2" project (PLC2). This means that an IO controller outside the project is to have access to the module or submodule. Figure 5-22 Configuring shared device 4. Select the interface module in the network view or device view of project "Shared-Device2". 5. Select the "Shared Device" area in the Inspector window. A table shows which CPU has access to the respective module or submodule for all configured modules. 6. Select the setting "---" for all modules and submodules that are to be located in the address range of the CPU from the "Shared-Device-1" project (PLC1). 7. Finally, check whether the settings for access are "complementary" for each module or submodule in both projects. This means that if the local CPU has access in one project, the option "---" must be set in the other project and vice versa. Special consideration: The option "---" for the PROFINET interface and therefore for the ports makes the associated parameters read-only and not changeable. Parameters of the PROFINET interface and port parameters can only be edited in the project in which the PROFINET interface is assigned to the local CPU. The ports can be interconnected in both projects regardless of this. 8. Check whether the same IP address parameters and device name are set for the shared device in all projects. Check whether the same S7 subnet ID is set in all projects for the subnet to which the shared device is connected (subnet properties, "General" area in the Inspector window). Note If you make changes to the shared device: Make the same changes in each project on the shared device. Make sure that only one IO controller has access to a module or submodule. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 143 Functions 5.3 Shared device Procedure - Adjusting the real-time settings To ensure that all IO controllers and shared devices are operated with the appropriate send clock and that the update times are calculated correctly based on the communication load, you must adjust and check the following settings: 1. Select the project whose IO controllers have access to the PROFINET interface and the ports of the shared device. 2. Select the interface module of the shared device in the network view. 3. In the Inspector window, navigate to the "PROFINET interface > Advanced options > Real time settings > IO cycle" area. 4. In the "Shared Device" area, set the number of project-external IO controllers. The maximum number depends on the IO device (specification in GSD file). 5. You must set the same send clock for each IO controller that has access to modules and submodules of the shared device: – If you configure the IO controller with STEP 7 (TIA Portal): Open the corresponding project. Select the PROFINET interface of the IO controller. Select the "Advanced options > Real time settings > IO communication" area in the Inspector window and set the shared send clock. – If you configure the IO controller with a different engineering tool: Select the PROFINET interface of the shared device in STEP 7 (TIA Portal) and read out the send clock on the shared device ("Advanced options > Real time settings" area) Enter the read send clock in the engineering tool. – Special consideration: If you configure all IO controllers that have access to the shared device in STEP 7 (TIA Portal or V5.5), you can set shorter send clocks on the IO controller than supported by the shared device (send clock adaptation). Compiling and loading You must compile the configurations for the different IO controllers and load them to the CPUs one after the other. Due to the distributed configuration with separate projects, STEP 7 does not output consistency errors in the case of incorrect access parameter assignment. Example for incorrect access parameter assignment: ● Several IO controllers have access to the same module ● IP address parameters or send clocks are not identical PROFINET with STEP 7 V15 144 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device These errors do not show up until operation and are output as configuration errors, for example. Note After a configuration has been loaded in the IO controller, non-assigned modules or submodules retain their current parameterization state to ensure the independence from the parameterizations of other IO controllers. 5.3.3 Configuring an I-device as a shared device Below, you will find a description of how you configure an S7-1500 as an I-device with STEP 7 Version 13 or higher and then use it in two projects as a shared device. A "distributed" configuration with different engineering tools for different IO controller families is generally also possible here. The procedure described below is based on STEP 7 V13 and is limited to a configuration with two IO controllers of the S7-1500 family that share the transfer areas of an I-device as a shared device. The I-device itself is also an S7-1500 CPU. Three projects are created with one IO controller each (PLC-I-Device, PLC_1, and PLC_2). PLC-I-Device is used to configure the I-device. The PROFINET GSD variant of PLC-I-Device is used in the PLC_1 and PLC_2 projects in order to assign the transfer areas in the respective higher-level IO controller. Shared I-device concept For the introduction of the shared I-device concept, two roles are distinguished: ● The role of manufacturer (e.g., machine manufacturer): The manufacturer configures and programs an I-device that performs a particular automation task. Transfer areas are defined as the I/O interface to the operator of the machine. These transfer areas can be assigned to different IO controllers. For the connection to higher-level IO controllers, the manufacturer provides a PROFINET GSD file and discloses the transfer areas via which the I-device can be accessed. ● The role of the operator: The operator uses the I-device as a PROFINET GSD variant during configuration of the PROFINET IO system and, in this process, specifies the I/O addresses under which the IO controllers access the transfer areas. Manufacturer view You assign the following parameters for an S7-1500 CPU as an I-device: centralized and distributed I/O, the desired transfer areas, and the number of IO controllers having access to this I-device (always greater than 1 for a shared device!). Special consideration: The I-device is configured without a higher-level IO controller. As a result, only the local I/O addresses of the transfer area are available (= "Address in the Idevice") in order to create the user program for editing the addresses from the transfer area. The I-device that has been completely configured except for the connection to the higherlevel IO controller is loaded to the S7-1500 CPU. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 145 Functions 5.3 Shared device You export a PROFINET GSD file from the I-device configuration. Figure 5-23 Exporting an I-device as a GSD file PROFINET with STEP 7 V15 146 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device Operator view You must install the PROFINET GSD file created from the I-device configuration in all engineering systems that are involved in configuring a PROFINET IO system with this shared I-device. If all uses of this I-device will be configured with STEP 7 V13, it is sufficient to install the GSD file in STEP 7. You configure the I-device as a GSD variant on the PROFINET IO system in the projects involved. In STEP 7 V13, this I-device can be found under "Other field devices > PROFINET IO > PLCs & CPs" following installation. Figure 5-24 Configuring an I-device as a GSD file PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 147 Functions 5.3 Shared device In each of the projects involved, you define which transfer areas are assigned exclusively to the higher-level IO controller (default setting: all). You set the other transfer areas to "---" (not assigned). As a result of this setting, the local IO controller has no access to this transfer area and it can therefore be assigned to another IO controller in another project. Figure 5-25 Setting the access to the shared I-device. You adapt the addresses from the view of the IO controller in the device overview. To open the device overview, double-click the I-device. Figure 5-26 I/O addresses of the transfer areas in the device overview Requirements ● STEP 7 as of V13 PROFINET with STEP 7 V15 148 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device Procedure - Creating the PLC-I-device project To create the project with a shared I-device, follow these steps: 1. Start STEP 7. 2. Create a new project with the name "PLC-I-device". 3. Insert, for example, a CPU 1518-4 PN/DP from the hardware catalog in the network view. Assign the name "PLC-I-device". 4. Double-click the IO device and configure all required modules and submodules. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 149 Functions 5.3 Shared device 5. Assign the module parameters. In particular, the following settings for the CPU are necessary in the area of the PROFINET interface [X1]: – Enable the "IO device" option in the "Operating mode" area. – Configure the transfer areas in the "Operating mode" > "I-device configuration" area. The "Address in IO controller" column remains empty because no IO controller is assigned. Note: To change an input area to an output area, and vice versa, you must navigate to the area of the corresponding transfer area. Figure 5-27 Changing the address type for the transfer area PROFINET with STEP 7 V15 150 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device – Select the number of IO controllers (at least two) that will access the shared I-device during operation ("Operating mode" > "Real time settings" area, "Shared Device" area). 6. Save the project. 7. Click the "Export" button ("Mode" > "I-device configuration" area, "Export general station description file (GSD)" section). If you do not change the name in the Export dialog, the GSD file has a name in the form "GSDML-V2.31-#Siemens-PreConf_PLC-I-Device-20130925-123456", for example. Procedure - Creating the PLC_1 project To create the first project with a shared I-device, follow these steps: 1. Start STEP 7. 2. Install the PROFINET GSD file from the export of the I-device CPU (PLC-I-Device). 3. Create a new project with the name "PLC_1". 4. Insert, for example, a CPU 1516-3 PN/DP in the network view. The name of the CPU should be "PLC_1". 5. Insert the I-device from the hardware catalog (Hardware catalog: Other field devices > PROFINET IO > PLCs & CPs). 6. Assign the IO controller "PLC_1" to the I-device. 7. Select the "Shared Device" area in the properties of the I-device. In the table, all transfer areas and the PROFINET interface are assigned to the local IO controller (PLC_1). 8. Define the transfer areas to which the PLC_1 CPU should not have access. Select the "--" entry for these areas. These transfer areas are provided for PLC_2. 9. Save the project. Procedure - Creating the PLC_2 project To create the second project with a shared I-device, follow these steps: 1. Start STEP 7 once again. A new instance of STEP 7 opens. 2. In the new instance, create a new project with the name "PLC_2". 3. Insert, for example, a CPU 1516-3 PN/DP in the network view. Assign the name "PLC_2". 4. Insert the I-device from the hardware catalog (Hardware catalog: Other field devices > PROFINET IO > PLCs & CPs). 5. Assign the IO controller "PLC_2" to the I-device. 6. Adapt the access to the transfer areas as in the PLC_1 project. Ensure that no duplicate assignments result. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 151 Functions 5.3 Shared device 7. Adapt the parameters of the subnet and PROFINET interface. Because the shared Idevice involves the same device in different projects, these data must match. 8. Save the project. Both projects now have an identically configured shared I-device. The IO controller access and the parameters of the PROFINET interface should still be checked in the different projects during the next step. Summary - Assigning parameters for access to the shared device The transfer areas are automatically assigned to the local IO controller. To change the assignment, follow these steps: 1. Click the "PLC_I-Device" device in the network view of the "PLC_1" project, and select the "Shared Device" area. 2. A table shows which CPU has access to each of the configured transfer areas. The default setting is that the local CPU has access to all modules and submodules. 3. Keep the setting "PLC_1" for all transfer areas that are to remain in the address range of the local CPU Select the setting "---" for all transfer areas that are to be located in the address range of the "PLC_2" CPU from the "PLC_2" project. This means that an IO controller outside the project is to have access to the transfer area. 4. Follow the same procedure for the remaining projects. 5. Finally, check whether the settings for access are "complementary" for each module or submodule in both projects. This means that if the local CPU has access in one project, the option "---" must be set in the other project and vice versa. Special consideration: The option "---" for the PROFINET interface and therefore for the ports makes the associated parameters read-only and not changeable. Parameters of the PROFINET interface and port parameters can only be edited in the project in which the PROFINET interface is assigned to the local CPU. The ports can be interconnected in both projects regardless of this. 6. Check whether the same IP address parameters and device name are set for the shared device in all projects. Check whether the same S7 subnet ID is set in all projects for the subnet to which the shared device is connected (subnet properties, "General" area in the Inspector window). Note If you make changes to the I-device (e.g., change the number or length of the transfer areas): Export the I-device as a GSD file again. Re-install the GSD file in each project that uses the I-device as a shared device. Make sure that only one IO controller has access to a transfer area. PROFINET with STEP 7 V15 152 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device Procedure - Adjusting the real-time settings To ensure that all IO controllers and shared devices are operated with the appropriate send clock and that the update times are calculated correctly based on the communication load, you must adjust and check the following settings: 1. You must set the same send clock for each IO controller that has access to modules and submodules of the shared device: – If you configure the IO controller with STEP 7 (TIA Portal): Open the corresponding project. Select the PROFINET interface of the IO controller. Select the "Advanced options > Real time settings > IO communication" area in the Inspector window and set the shared send clock. – If you configure the IO controller with a different engineering tool: Select the PROFINET interface of the shared device in STEP 7 (TIA Portal) and read out the send clock on the shared device ("Advanced options > Real time settings" area) Enter the read send clock in the engineering tool. – Special consideration: If you configure all IO controllers that have access to the shared I-device in STEP 7 (TIA Portal or V5.5), you can set shorter send clocks on the IO controller than supported by the shared device (send clock adaptation). Compiling and loading You must compile the configurations for the different IO controllers and load them to the CPUs one after the other. Due to the distributed configuration with separate projects, STEP 7 does not output consistency errors in the case of incorrect access parameter assignment. Example for incorrect access parameter assignment: ● Several IO controllers have access to the same module ● IP address parameters or send clocks are not identical These errors do not show up until operation and are output as configuration errors, for example. Note After a configuration has been loaded in the IO controller, non-assigned modules or submodules retain their current parameterization state to ensure the independence from the parameterizations of other IO controllers. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 153 Functions 5.3 Shared device 5.3.4 Module-internal shared input/shared output (MSI/MSO) Introduction This section describes the module-internal shared input/shared output (MSI/MSO) functionality for I/O modules that are operated on PROFINET. Module-internal shared input/shared output functionality The module-internal shared input (MSI) function allows an input module to make its input data available to up to four IO controllers. Each controller has read access to the same channels. The following figure shows the MSI functionality. ① ② ③ ④ ⑤ CPU 1516-3 PN/DP as IO controller CPU 1511-1 PN as IO controller Input module with MSI Read access to the input channels of the input module Write access to the channels of the I/O module (only with MSO) Figure 5-28 Example configuration with MSI PROFINET with STEP 7 V15 154 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device The module-internal shared output (MSO) function allows an output module to make its output data available to up to four IO controllers. An IO controller has write access to the channels of the output module. Up to three IO controllers can additionally have read-access to the channels. The following figure shows the MSO functionality. ① ② ③ ④ ⑤ CPU 1516-3 PN/DP as IO controller CPU 1511-1 PN as IO controller Output module with MSO Write access to the output channels of the output module Read access to the output channels of the output module Figure 5-29 Example configuration with MSO Advantages of MSI/MSO Module-internal shared input/shared output (MSI/MSO) offers the following advantages: ● Real-time acquisition in multiple CPUs ● Lower costs due to saving on additional IO devices and modules ● Lower space requirements due to saving on additional IO devices and modules ● Reduced communication load because no CPU-CPU communication is needed ● No additional programming effort is needed for CPU-CPU communication PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 155 Functions 5.3 Shared device Requirements for the use of MSI/MSO Observe the following requirements: ● MSI/MSO can only be used with PROFINET IO ● Configuration software: STEP 7 (TIA Portal) as of V12 SP1 with GSD file; the modules are integrated in the hardware catalog as of V13. ● The IM 155-5 PN ST interface module and the modules support MSI/MSO as of firmware version V2.0.0. Boundary conditions for the use of MSI/MSO Note the following boundary conditions: ● The use of MSI/MSO is not possible in the case of module grouping. ● Modules with MSI/MSO cannot be operated in isochronous mode. ● The maximum number of IO controllers is dependent on the interface module. To find out how many IO controllers the interface module supports, refer to the manual for the respective interface module. MSI submodules The input values of all channels are copied to a basic submodule and up to three other MSI submodules during MSI configuration of an input module. The channels of the module are then available with identical input values in the basic submodule and the MSI submodules. The MSI submodules can be assigned to up to three IO controllers when the module is used in a shared device. Each IO controller has read access to the same channels. PROFINET with STEP 7 V15 156 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device The following figure shows a digital input module with the basic submodule and three MSI submodules. Each submodule is assigned to an IO controller. Diagnostics and parameter assignment of the digital input module can be performed from the IO controller 1 via the basic submodule. ① ② Read access Parameter assignment and system diagnostics Figure 5-30 DI module with MSI submodules Value status (Quality Information, QI) The meaning of the value status depends on the submodule to which it pertains. With basic submodule (= 1st submodule), the "0" value status indicates that the value is incorrect. With an MSI submodule (2nd to 4th submodule), the "0" value status indicates that the value is incorrect or the basic submodule has not yet been configured (not ready). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 157 Functions 5.3 Shared device MSO submodules During MSO configuration of an output module, the output values of all channels of the module are copied from a basic submodule to up to three other MSO submodules. The channels of the module are then available with identical values in the basic submodule and the MSO submodules. The MSO submodules can be assigned to up to three IO controllers when the module is used in a shared device. ● The IO controller to which the basic submodule is assigned has write access to the outputs of the module. The basic submodule therefore occupies output addresses in the process image of the IO controller. ● The IO controllers to which the MSO submodules are assigned have read access to the outputs of the module. MSO submodules therefore occupy input addresses in the process image of the IO controller. The following figure shows a digital output module with the basic submodule and three MSO submodules. Each submodule is assigned to an IO controller. Diagnostics and parameter assignment of the digital output module can be performed from IO controller 1 via the basic submodule. ① ② ③ Write access Read access Parameter assignment and system diagnostics Figure 5-31 DQ module with MSO submodule PROFINET with STEP 7 V15 158 Function Manual, 12/2017, A5E03444486-AH Functions 5.3 Shared device Value status (Quality Information, QI) The meaning of the value status depends on the submodule to which it pertains. With basic submodule (= 1st submodule), the "0" value status indicates that the value is incorrect. With MSO submodule (= 2nd to 4th submodule) the "0" value status indicates that the value is incorrect or one of the following errors has occurred: ● The basic submodule parameters have not yet been assigned (not ready for operation). ● The connection between the IO controller and the basic submodule has been interrupted. ● The IO controller of the basic submodule is in STOP or POWER OFF state. Configuring I/O modules with MSI/MSO submodules Requirements ● Configuration software STEP 7 as of V13 ● IO device supports MSI/MSO (for example IM 155-5 PN ST as of firmware version 2.0.0) Procedure 1. In the network view of STEP 7, insert an IM 155-5 PN ST interface module as of V2.0. 2. Double-click the IO device. You are now in the device view. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 159 Functions 5.3 Shared device 3. Place the I/O modules from the hardware catalog in a suitable slot. 4. Add MSI/MSO submodules to the I/O modules: – Input modules: Select the number of MSI submodules under "Module parameters " > "DI configuration" or "AI configuration" in the area "Copy of module for Shared Device (MSI)". – Output modules: Select the number of MSO submodules under "Module parameters " > "DQ configuration" or "AW configuration" in the area "Copy of module for shared device (MSO)". Figure 5-32 Configuring I/O modules with MSI/MSO Assigning MSI/MSO submodules to an IO controller You can assign the submodules in a shared device to an IO controller. For more information, refer to Configuring shared device (Page 141). Configuring access to a shared device and the module-internal shared input / shared output (MSI /MSO) function You can learn how to access a shared device and the MSI /MSO function in STEP 7 with this FAQ (https://support.industry.siemens.com/cs/ww/en/view/109736536). PROFINET with STEP 7 V15 160 Function Manual, 12/2017, A5E03444486-AH Functions 5.4 Media redundancy (ring topologies) 5.4 Media redundancy (ring topologies) In order to increase the network availability of an Industrial Ethernet network with optical or electrical linear bus topologies, you can convert a linear bus topology to a ring topology by joining the ends together. Media redundancy in ring topologies Devices in a ring topology can be IO devices, IO controllers, external switches and/or the integrated switches of communication modules. To set up a ring topology with media redundancy, you need to bring together the two free ends of a linear bus topology in one device. Closing the linear bus topology to form a ring is achieved with two ports (ring ports) of a device in the ring. One device of the resulting ring then takes over the role of the redundancy manager. All other devices in the ring are redundancy clients. ① ② ③ Redundancy manager Test frames Redundancy clients Figure 5-33 Media redundancy in ring topology The ring ports of a device are the ports that establish the connection to the two neighboring devices in the ring topology. The ring ports are selected and set in the configuration of the relevant device (is also preset, if applicable). How media redundancy works in a ring topology The data paths between the individual devices are automatically reconfigured if the ring is interrupted at any point. The devices are available again after reconfiguration. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 161 Functions 5.4 Media redundancy (ring topologies) In the redundancy manager, one of the two ring ports is blocked in uninterrupted network operation for normal communication so that no data frames are circulated. In terms of data transmission, the ring topology is a linear bus topology. The redundancy manager monitors the ring for interruptions. For this purpose, it sends test frames not only from ring port 1 but also from ring port 2. The test frames pass through the ring in both directions until they arrive at the other ring port of the redundancy manager. An interruption of the ring can be caused by loss of the connection between two devices or by failure of a device in the ring. If the test frames of the redundancy manager no longer arrive at the other ring port during an interruption of the ring, the redundancy manager connects its two ring ports. This substitute path once again restores a functioning connection between all remaining devices in the form of a linear bus topology. The time between the ring interruption and restoration of a functional linear topology is known as the reconfiguration time. As soon as the interruption has been eliminated, one of the two ring ports is blocked again in the redundancy manager. The redundancy clients are informed about the change and use the original paths to the other devices again. Media redundancy method The standard method of media redundancy in SIMATIC is MRP (Media Redundancy Protocol) with a typical reconfiguration time of 200 ms. Up to 50 devices can participate per ring. In addition, the real-time capable media redundancy process MRPD (Media Redundancy with Planned Duplication of frames) is also available. 5.4.1 Media Redundancy Protocol (MRP) Media Redundancy Protocol (MRP) The "MRP" process works in conformity with the Media Redundancy Protocol (MRP) that is specified in the standard IEC 62439-2. Requirements ● All devices in the ring support MRP. ● You have complied with the rules for topology set out below. STEP 7 monitors compliance with the rules during compilation and outputs corresponding alarms. Topology The following schematic shows a possible topology for devices in a ring with MRP. The devices inside the shaded oval are in the redundancy domain. Example of a ring topology with the MRP media redundancy protocol: PROFINET with STEP 7 V15 162 Function Manual, 12/2017, A5E03444486-AH Functions 5.4 Media redundancy (ring topologies) Figure 5-34 Example of a ring topology with the MRP media redundancy protocol: The following rules apply to a ring topology with media redundancy using MRP: ● All devices must be connected to one other via their ring ports. ● All devices in the ring belong to the same redundancy domain. ● A device in the ring takes on the task of a redundancy manager. – One device only has the role of "Manager". No other device may have the role of "Manager". Or – Several devices in the ring have the role of "Manager (auto)". The devices with the role of "Manager (auto)" then negotiate between themselves which device is to take on the role of redundancy manager. In this case, no device is permitted to have the role of "Manager". ● All other devices in the ring are redundancy clients. ● You can connect up to 50 devices in a ring. Non MRP-compliant devices can, for example, be connected to the ring via a SCALANCE X switch or via a PC with a CP 1616. Rules for loading the devices of an MRP domain When loading devices of an MRP domain, frame loops can occur and result in network failure if there is an invalid MRP configuration. Example: You change the MRP roles of several devices and consecutively load the configuration into the devices involved. Configurations can arise that contradict the roles mentioned above, for example, there may be devices that simultaneously have the "Manager" and "Manager (auto)" roles in the ring. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 163 Functions 5.4 Media redundancy (ring topologies) In order to ensure that an invalid MRP configuration does not result in the failure of the network, delete the ring before loading. Follow these steps: 1. Delete the ring. 2. Load the error-free and consistent MRP configuration from your project onto all the devices involved and ensure that the devices are in data exchange mode (i.e. the application relations (ARs) are set up). 3. Close the ring. Boundary conditions MRP and RT RT operation is possible with the use of MRP. Note The RT communication is disrupted (station failure) if the reconfiguration time of the ring is greater than the selected response monitoring time of the IO device. This is why you should select a response monitoring time of the IO devices that is sufficiently large. MRP and IRT IRT mode is not possible together with MRP. If you want to use media redundancy together with IRT in a ring, only use devices that support MRPD. MRP and TCP/IP (TSEND, HTTP, ...) The TCP/IP communication with MRP is possible, because lost data packages are resent, if applicable. MRP and prioritized startup If you configure MRP in a ring, you cannot use the "prioritized startup" function in PROFINET applications on the devices involved. If you want to use the "prioritized startup" function, then you must disable MRP in the configuration (the device may also not be part of the ring). 5.4.2 Configuring media redundancy Configuring MRP Proceed as follows to create a PROFINET IO configuration with MRP in STEP 7: 1. Generate a ring via the port interconnections in the topology view. First interconnect the devices to a line topology. Connect the unassigned port of the last device in the line with PROFINET with STEP 7 V15 164 Function Manual, 12/2017, A5E03444486-AH Functions 5.4 Media redundancy (ring topologies) the unassigned port of the first device. The following example shows one CPU 1516-3 PN/DP and two interface modules IM 155-6 PN HF that are interconnected in a ring in the topology view of STEP 7. Figure 5-35 Configuring media redundancy 2. Select the PROFINET IO system in the network view. 3. In the Inspector window, navigate to "Properties" > "General" > "PROFINET" > "MRP domains" in the "Ring interconnections" field. This field shows you all the topological rings in the IO system with the associated MRP domains. 4. Select the ring generated above in the "Ring interconnections" field. The table below it shows all the PROFINET devices in the ring. 5. Set the media redundancy role for the PROFINET devices in the MRP role column. Figure 5-36 MRP domain Automatic MRP configuration You can also have the media redundancy roles assigned automatically for your PROFINET devices in the ring. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 165 Functions 5.4 Media redundancy (ring topologies) To have the media redundancy roles assigned automatically, click the "Configure MRP automatically" button. STEP 7 automatically assigns the media redundancy role for each device in the ring. After the automatic MRP configuration, you can make modifications to the media redundancy roles in the "MRP role" column. "Media redundancy" setting options Media redundancy role Depending on the device used, the roles "Manager", "Manager (Auto)", "Client" and "Not device in the ring" are available. Rules: ● A ring must have precisely one device with the role "Manager". No additional devices with the role "Manager" or "Manager (Auto)" are permissible. All the other devices may only have the "Client" role. ● If a ring has no device with the "Manager" role, the ring must at least have a device with the role "Manager (Auto)". Any number of devices with the "Client" role may exist. Ring port 1 / Ring port 2 Select one at a time those ports you want to configure as ring port 1 or ring port 2. The dropdown list box shows the selection of possible ports for each device type. If the ports are set at the factory, then the fields are unavailable. If you use single-stage commissioning, use the preset ring ports in STEP 7. Diagnostic interrupts If diagnostic interrupts to the MRP state are to be output in the local CPU, select the "Diagnostic interrupts" check box. The following diagnostic interrupts can be configured: ● Wiring or port error Diagnostic interrupts will be generated for the following errors in the ring ports: – A neighbor of the ring port does not support MRP. – A ring port is connected to a non-ring port – A ring port is connected to the ring port of another MRP domain. ● Interruption / return (redundancy manager only) If the ring is interrupted and the original configuration is returned, diagnostic interrupts will be generated. If both of these interrupts occur within 0.2 seconds, this indicates an interruption of the ring. You can respond to these events in the user program by programming the appropriate response in the diagnostic error interrupt OB (OB 82). PROFINET with STEP 7 V15 166 Function Manual, 12/2017, A5E03444486-AH Functions 5.4 Media redundancy (ring topologies) 5.4.3 Media Redundancy with Planned Duplication of frames (MRPD) MRP extension "Media Redundancy with Planned Duplication of frames" (MRPD) The MRP extension "Media Redundancy with Planned Duplication of frames" (MRPD) provides the advantage that, in the case of a failure of a device or a line in the ring, all other devices continue to be supplied with IO data without interruption and with short update times. MRPD is based on IRT and MRP. To realize media redundancy with short update times, the PROFINET devices participating in the ring send their data in both directions. The devices receive this data at both ring ports so that there is no reconfiguration time. Requirements for media redundancy with MRPD ● All the devices of the ring must support MRPD, for example interface module IM 155-6 PN HS as of firmware version 4.0. ● You have configured MRP for all the devices of the ring. You have assigned the MRP role "Not device in the ring" to devices that are not located in the ring. ● You have configured IRT for all the involved components. Configuring MRPD You do not have to explicitly activate MRPD in STEP 7. The function is available automatically as soon as all the requirements for MRPD are fulfilled. Redundancy levels of IO devices with MRPD The redundancy level of an IO device specifies how strongly the real-time communication is influenced in the case of a power interruption between an IO device and its IO controller. ● Full redundancy: No influence, because the IO controller and IO device are located in the same ring. ● Partial redundancy: – If the interruption takes place on a non-redundant part (line) between the IO device and IO controller, real-time communication is influenced. – If the interruption takes place on a redundant part (ring), real-time communication is not influenced. ● No redundancy: No redundant path between the IO device and its IO controller, communication is always influenced. The figure below shows the redundancy levels of the IO devices for an example configuration with MRPD. The three devices in the ring and the switch have the redundancy level "Full redundancy". Device 4 has the redundancy level "Partial redundancy", because the connection between the switch and the device is not redundant. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 167 Functions 5.4 Media redundancy (ring topologies) ① ② ③ ④ IO controller in the ring IO device in the ring with redundancy level "Full redundancy" Switch in the ring with redundancy level "Full redundancy" IO device in the spur with the redundancy level "Partial redundancy" Figure 5-37 Example configuration with MRPD PROFINET with STEP 7 V15 168 Function Manual, 12/2017, A5E03444486-AH Functions 5.4 Media redundancy (ring topologies) The figure below shows the display of the redundancy levels in STEP 7 for the example configuration. Figure 5-38 5.4.4 Display of the redundancy levels in STEP 7 Multiple rings Multiple rings Use multiple rings to achieve higher availability for PROFINET IO networks with star topology. In a multiple ring configuration, several PROFINET lines lead from a switch (star topology). The individual PROFINET lines lead from IO device to IO device. Redundant PROFINET cables run back to the switch from the last IO device on each individual line. The switch operates as a manager. The manager must have two ring ports for each ring. Several rings are possible. For example, the SCALANCE X414 as of firmware version 3.10 supports up to 4 rings. The manager monitors all the rings individually: It checks for each particular ring (an MRP domain) whether the transmission path is intact. To do this, it uses an MRP instance in each case. An MRP instance is required for each connected ring (set up automatically by STEP 7). Figure 5-39 Configuration with several rings PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 169 Functions 5.4 Media redundancy (ring topologies) Requirements ● SCALANCE X414 as of version 3.10 ● SCALANCE X300 as of version 4.0 (configured via GSD file) Rules for the configuration of multiple rings ● MRP role at multiple rings: – The device that belongs to all the rings must have the MRP role in every instance that is entered in the GSD file in the "SupportedMultipleRole" attribute. – The switches from the series SCALANCE X300 as of version 4.0 and the switch X414 as of version 4.10 support the MRP role "Manager" for multiple rings. ● If the device that belongs to all rings has the "Manager" role in one ring, no devices with the "Manager (Auto)" role may exist in this ring. Configuring multiple rings To configure an MRP configuration with multiple rings, follow these steps: 1. In the topology view, interconnect the ring ports of the devices that are intended to belong to an MRP domain to form a ring. 2. Select the PROFINET IO system in the network view. 3. In the Inspector window, navigate to "Properties" > "General" > "PROFINET" > "MRP domains" in the "Ring interconnections" field. This field shows you all the topological rings in the IO system with the associated MRP domains. 4. Select one of the rings generated above in the "Ring interconnections" field. The table below it shows all the PROFINET devices in the ring. 5. Set the media redundancy role for the PROFINET devices in the MRP role column. Example of multiple rings The following figure shows an example configuration for multiple rings. Figure 5-40 Example configuration with two rings ① and ② PROFINET with STEP 7 V15 170 Function Manual, 12/2017, A5E03444486-AH Functions 5.4 Media redundancy (ring topologies) In the example, Switch 1 belongs to two MRP rings. Ring 1 is formed by Switch 1 and PLC 1, Ring 2 by Switch 1 and IO device 1. STEP 7 automatically assigns the "Manager" role to the switch. The other devices receive the "Client" role. The manager is located at the point of intersection of the two rings 1 and 2. The manager monitors the two rings separately. To do this, it uses two MRP instances. One MRP instance checks whether all devices in ring 1 are reachable, another instance monitors whether all devices in ring 2 are reachable (only one device in each case in the example). You can configure each MRP instance separately. The following figure shows the two MRP instances in the manager (PROFINET interface of the switch). Here in the example, MRP instance 1 checks whether the devices in the MRP domain "mrpdomain-1" can be reached. The MRP instance 2 is responsible for monitoring the devices of the MRP domain "mrpdomain-2". Figure 5-41 Setting media redundancy for multiple rings PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 171 Functions 5.4 Media redundancy (ring topologies) The following figure shows Ring 1 (mrpdomain-1). The participants of the mrpdomain-1 are the PROFINET interface of the CPU as the "Client" and the MRP interface 1 of the PROFINET interface of the switch as the "Manager". Figure 5-42 Ring 1 The following figure shows Ring 2 (mrpdomain-2). The participants of the mrpdomain-2 are the PROFINET interface of the IO device as the "Client" and the MRP instance 2 of the PROFINET interface of the switch as the "Manager". Figure 5-43 Ring 2 PROFINET with STEP 7 V15 172 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication 5.5 Real-time communication 5.5.1 Introduction Properties PROFINET IO is a scalable real-time communication system based on the Layer 2 protocol for Fast Ethernet. With the RT transmission method, two real-time-support performance levels are available for time-critical process data and IRT for high-accuracy and also isochronous processes . Figure 5-44 Real-time communication performance Real-time communication and IT communication Industrial communication, especially in the factory automation and process automation, requires a punctual and deterministic data transmission. This is why, for the cyclic exchange of time-critical IO user data, PROFINET IO does not use TCP/IP, it uses real-time communication (RT) or isochronous real-time communication (IRT) for the synchronized data exchange in reserved time intervals. Fields of application of PROFINET with RT PROFINET with RT is suited for: ● Time-critical applications in factory automation ● The implementation of large quantity structures in line process plants PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 173 Functions 5.5 Real-time communication Fields of application of PROFINET with IRT PROFINET with IRT is particularly suitable for: ● Considerable deterministics with large quantity structures concerning the I/O user data communication (productive data) ● Considerable performance also with many devices concerning the I/O user data communication (productive data) ● Parallel transfer of productive and TCP/IP data via a cable, even with considerable data traffic whilst ensuring the forwarding of productive data by reserving the transmission bandwidth. International standard IEC 61158 The communication procedures RT and IRT are standardized in the international standard IEC 61158. 5.5.2 RT PROFINET IO with real-time communication (RT) is the ideal solution for integrating IO systems. This is a solution that also uses standard Ethernet in the devices and commercially available industrial switches as infrastructure components. A special hardware support is not required. If you want to use PROFINET functions that provide an additional value, such as topology detection, diagnostics, device exchange without exchangeable medium/PG, you have to use switches that support the PROFINET standard according to the IEC 61158 standard. In the integrated switches of PROFINET devices and PROFINET switches (e.g., the SCALANCE product family), PROFINET functions in accordance with the PROFINET standard are implemented and can be used without restriction for integration in the PROFINET IO system (see also section Active network components (Page 31). Real-time communication (RT) PROFINET IO frames have priority over standard frames in accordance with IEEE802.1Q. This ensures the required determinism in the automation technology. The data is transferred via prioritized Ethernet frames. With RT, you can achieve update times ≥ 250 μs with RT. Switching mechanisms Switches in SIMATIC meet the real-time requirements with two mechanisms on PROFINET: "Store and forward" and "Cut through". Store and forward In the Store and forward method, the switch stores the frames completely and places them in a queue. If the switch supports the international standard IEEE 802.1Q, then the data is sorted according to its priority in the queue. The frames are then forwarded selectively to the specific port that can access the addressed node (Store and forward). PROFINET with STEP 7 V15 174 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication Cut through In the Cut through process the entire data package is not stored temporarily in a buffer, it is passed directly onto the target port as soon as the target address and the target port have been determined. The times required by the data package to pass through the switch are then minimal and independent of the frame length. The data are only stored temporarily in accordance with the Store and forward process as per priority when the section between the target segment and the port of the next switch is occupied. 5.5.3 IRT Isochronous real-time communication (IRT) IRT is a synchronized communication protocol for cyclic exchange of IRT data between PROFINET devices. A reserved bandwidth is available in the send cycle for IRT data. The reserved bandwidth ensures that the IRT data can be transferred at reserved synchronized intervals, without being influenced also by higher other network loads (such as TCP/IP communication, or additional real-time communication). Advantages PROFINET with IRT is synchronized communication in reserved time intervals. With IRT you have the option to be able to control time-critical applications such as motion control via PROFINET. With IRT you use further advantages: ● High-precision deterministics allow highest control quality and thus, for example, exact positioning of axes ● Simple and flexible integration of PROFINET devices for real-time applications in existing company networks ● Shortest response times and highest deterministics by means of bandwidth reservation and thus also for applications that have to satisfy highest performance requirements (e.g., printing control/position control for presses, print-mark recognition with packaging machines) ● Secured standard communication parallel to real-time communication via the same transmission medium ● You can continue to use standard components for your PROFINET IO system outside of the sync domain PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 175 Functions 5.5 Real-time communication Properties of isochronous real-time Topology configuration is a prerequisite for IRT. In addition to the reserved bandwidth, the frames from defined transmission paths are exchanged for the further optimization of data transfers. For this, the topological information from the configuration is used for planning the communication. Transmission and reception points of every individual data frame at every communication node are thus guaranteed. This allows you to achieve optimal usage of the bandwidth and reach the best possible performance in the PROFINET IO system. Use of IRT allows you to achieve update times with very high deterministics ≥ 125 µs and a jitter accuracy of the send clock < 1 µs. Isochronous applications are possible with IRT (see section Isochronous mode (Page 198)). * The minimum update time depends on the CPU used. The update times supported by a CPU are listed in the technical specifications of the CPU manual. Note IWLAN and IRT PROFINET devices that are connected to PROFINET IO via access points, do not support IRT. Synchronization The prerequisite for the IRTcommunication is a synchronization cycle for all PROFINET devices in a sync domain for distributing a mutual time basis. A synchronism of the transmission cycle of the PROFINET devices within a sync domain is achieved with this basic synchronization. A sync master specifies the clock to which sync slaves are synchronized. An IO controller or an IO device can have the role of sync master. If the sync master fails, all IO devices with IRT will fail. Sync master and sync slaves are always devices in a sync domain. Bandwidth is reserved within the sync domain for IRT communication. Real-time and non-real-time communication (TCP/IP communication) is possible outside of the reserved bandwidth. Default sync domain If you have created a PROFINET subnet, a special sync domain is automatically created, the default sync domain. All PROFINET devices configured for the PROFINET subnet automatically belong to this sync domain. For additional information on creating sync domains, refer to the STEP 7 online help. PROFINET with STEP 7 V15 176 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication Time ranges of the communication cycle The communication cycle is divided into three time ranges, which are shown in the following chart: Figure 5-45 ● Reserving bandwidth IRT data (synchronized communication) This time range can be reserved in specific steps, depending on the send clock. Only IRT data is transmitted during this time range. ● RT data (real-time communication) The cyclic RT data is transferred in this time range. RT data is prioritized over "normal" TCP/IP data. TCP/IP data or Ethernet frames can have a priority of between 1 and 7. RT data have the Priority 6. ● TCP/IP data (standard communication) Standard communication (e.g., TCP/IP) is transmitted in the remaining interval of the communication cycle. In STEP 7, you can set the ratio of the bandwidth usage of cyclic IO data to standard communication. For information on how to set the bandwidth usage, refer to the section Setting the bandwidth usage for the send clock (Page 181) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 177 Functions 5.5 Real-time communication 5.5.4 Comparison of RT and IRT The most important differences between RT and IRT Table 5- 2 Comparison between RT and IRT Property RT IRT Transmission method Prioritizing the RT frames through Ethernet priority (VLAN tag) Path-based switching on the basis of a communication path plan; no transmission of TCP/IP frames in the time range with IRT communication. Determinism Variance of the duration of transmission by the shared use of the transmission bandwidth with other protocols (e.g., TCP/IP) Exact, planned transmission, transmission and reception times are guaranteed for all topologies. Hardware support through special Not required Ethernet controllers is required Required Isochronous application - Yes Starting time of the isochronous application - The point in time for the reception of the data is planned exactly. Application can be started synchronized to the cycle. 5.5.5 Configuring PROFINET IO with IRT Introduction If you want to configure a PROFINET IO system with IRT, you have to configure the PROFINET IO devices. These PROFINET devices must support IRT. Set which device acts as the sync master and synchronizes the other devices. This is done by configuring a sync domain with a sync master and at least one sync slave. Requirement ● There is an IO system with an IO controller and at least one IO device. ● You have configured the topology for the IO system. ● The devices support IRT. PROFINET with STEP 7 V15 178 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication Procedure Proceed as follows to enable an existing IO system for the use of IRT: 1. Select the PROFINET interface of the IO controller. 2. In the Inspector window, navigate to "Advanced options > Real time settings > Synchronization". Figure 5-46 IRT configuring sync master 3. Assign the IO controller the role of sync master under "Synchronization role". 4. Select the PROFINET interfaces of an associated IO device. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 179 Functions 5.5 Real-time communication 5. In the Inspector window, navigate to "Advanced options > Real time settings > Synchronization". Figure 5-47 IRT configuring sync slave 6. Activate the RT class "IRT". The IO device will then automatically be assigned the synchronization role "sync slave". 7. You can check and correct your settings at any time using the "Domain settings" button. Or 1. Highlight the PROFINET IO system in the network view. 2. Click on the PROFINET IO system. PROFINET with STEP 7 V15 180 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication 3. Navigate to the device of the required sync domain in the Inspector window. Figure 5-48 IRT configuring sync domain 4. Enter all necessary settings in the tables: – Select an IO system. – Set the synchronization role "sync master" for the IO controller. – Set the RT class for the IO devices to "IRT". The IO devices will then automatically be assigned the synchronization role "sync slave". You can now load the configuration to the relevant devices with PROFINET IRT. 5.5.6 Setting the bandwidth usage for the send clock Bandwidth level For PROFINET IO with IRT, you can specify the maximum portion of the send cycle that you want to use for cyclic IO communication. You have the following setting options for the bandwidth usage in STEP 7. ● Maximum 25% cyclic IO data. Focus on non-cyclic data. ● Maximum 37.5% cyclic IO data. Focus on non-cyclic data. ● Maximum 50% cyclic IO data. Balanced proportion. ● Maximum 90% cyclic IO data. Focus on cyclic IO data. (Requirement: The "Make 'high performance' possible" option is activated) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 181 Functions 5.5 Real-time communication Setting the bandwidth usage To set the bandwidth usage for a PROFINET IO system in STEP 7, follow these steps: 1. Select your IO system in the network view of STEP 7. 2. In the Inspector window, go to "Properties" > "General" > "PROFINET" > "Domain management" > "Sync domains" > "Name of the sync domain" > "Details". 3. Select the desired level of bandwidth usage from the "Bandwidth use" drop-drop down list box. Figure 5-49 Setting the bandwidth usage For information on how to set the bandwidth usage for IRT with maximum performance, refer to the section Configuration of IRT with high performance (Page 193) PROFINET with STEP 7 V15 182 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication 5.5.7 Setup recommendations for optimizing PROFINET Optimizing PROFINET with RT PROFINET provides you with high-performance communication on all levels. The following figures shows an example of an optimized PROFINET topology. Figure 5-50 Optimized PROFINET topology When setting up your PN network topology, take care that the various automation applications are distributed among separate network branches so that a sufficient bandwidth reserve will be available for future expansions. ● If you integrate standard Ethernet devices into the network topology or use standard Ethernet communication, take into account the network load caused by standard Ethernet and adapt the network topology as appropriate (max. bandwidth 100 Mbps). ● For communication with higher-level networks with a high data volume, use the most direct paths possible to the higher-level network infrastructure. Also observe the Installation Guideline (http://www.profibus.com/nc/download/installationguide/downloads/profinet-installation-guide/display/) of the PROFIBUS User Organization. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 183 Functions 5.5 Real-time communication Setting up PROFINET with IRT Keep in mind the following rules for setting up and operating a PROFINET IO system in IRT mode. These rules will ensure best possible operation of your PROFINET IO system. ● When using IRT, you must configure the topology. This will enable exact calculation of the update time, bandwidth, and other parameters. ● If you would like to use multiple sync domains, configure a sync boundary for the port which is currently connected to the PROFINET device of another sync domain. ● In a sync domain, you can only configure one sync master at a time. ● A PROFINET IO system may only be part of a single sync domain. ● If you configure PROFINET devices in a sync domain and want to synchronize with IRT, the PROFINET devices concerned must support IRT communication. ● If possible, use the same PROFINET device as the PROFINET IO controller and sync master. ● If only some of the PROFINET devices in a PROFINET IO system are synchronized, please keep in mind the following: Assign PROFINET devices that are not participating in the IRT communication to the RT class "RT" and the synchronization role "unsynchronized" in the sync domain. PROFINET with STEP 7 V15 184 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication Applications for CPU with multiple PROFINET IO interfaces ● Connecting machines: Your configuration contains machines located on separate IO lines. You can perform real-time communication between the CPUs over PROFINET IO interface X2. Use the I-device or shared I-device function for this purpose. The figure below shows an example configuration for two machines connected over the X2 interface with an I-device relationship. Figure 5-51 I-device connection over 2nd PNIO interface ● Distribution by automation tasks: – For automation tasks with high performance and deterministic requirements, use PROFINET with IRT over the X1 interface. – For other tasks that you can implement with RT, use the X2 interface. If you use interface X2 as the PROFINET IO interface for one of the following CPUs, this can affect performance: ● CPU 1515(F)-2 PN ● CPU 1515T(F)-2 PN ● CPU 1516(F)-3 PN/DP ● CPU 1516T(F)-3 PN/DP ● CPU 1516(F)pro-2 PN You can find additional information in the section PROFINET interface (Page 25) and in the Cycle and Response Times (https://support.industry.siemens.com/cs/ww/en/view/59193558) function manual. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 185 Functions 5.5 Real-time communication Topological overlap of IO systems in multi-controller applications In a configuration with multiple IO controllers, shared paths are subject to the combined network loads of all connected PROFINET IO systems. To avoid high communication loads in multi-controller applications, observe the following recommendations: ● Avoid paths that are shared by multiple IO systems. The figure below shows a configuration with two PROFINET IO systems that use the same paths. ① Shared path Figure 5-52 Multi-controller application with shared path In the figure below, the two PROFINET IO systems do not use shared paths. Figure 5-53 Multi-controller application with separate paths ● If separation is not possible: Increase the update time for the affected IO devices. Installation guidelines of the PROFIBUS user organization The installation guidelines can be found on the Internet (http://www.profibus.com/nc/download/installation-guide/downloads/profinet-installationguide/display/). PROFINET with STEP 7 V15 186 Function Manual, 12/2017, A5E03444486-AH Functions 5.5 Real-time communication 5.5.8 Limitation of the data infeed into the network Limiting the data infeed into the network on PROFINET interfaces The "Limit data infeed into the network" function limits the network load of standard Ethernet communication which is fed into the network by the interface to a maximum value. This does not apply to cyclic real-time communication (RT/IRT). In a PROFINET IO system, critical network loads can occur quickly with standard Ethernet communication, especially in line topologies. Devices which feed a lot of standard Ethernet communication into the PROFINET IO system, should support the function "Limit data infeed into the network". If necessary, you should optimize your topology by avoiding e.g. standard Ethernet devices in line topologies. You can find additional information on this in section Setup recommendations for optimizing PROFINET (Page 183). Depending on the interface, you can activate or deactivate the "Limit data infeed into the network" function. If you use the X1 interface of an S7-1500 CPU as the IO controller or Idevice, the "Limit data infeed into the network" function is always enabled. Example: If you are not using the X1 interface of an S7-1500 CPU as IO controller or I-device, you can enable or disable the function. Uses of the limitation of the data infeed to the network ● Division of the bandwidth for standard Ethernet communication between devices: In PROFINET networks cyclic real-time communication and standard Ethernet communication share the same network. This means that only a limited bandwidth remains for standard Ethernet communication. The limitation of the data infeed ensures that the remaining bandwidth for standard Ethernet communication is not used just by one device, but is divided between several devices. ● Smoothing peaks in the data infeed: The limitation of the data infeed smooths peak loads of standard Ethernet communication (for example, from Open User Communication, access by the Web server). ● Limiting problems in the data infeed: If applications in a device generate too much data, this data is not forwarded to the PROFINET network. Negative effects (for example data loss, communication breakdown) remain limited to the device and its communications partner. Other nodes are not disturbed. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 187 Functions 5.5 Real-time communication Setting limitation of the data infeed into the network for a CPU To set the limitation of the data infeed into the network, follow these steps: 1. In the network view of STEP 7, select the interface of the CPU. 2. In the Inspector window, go to "Properties" > "General" > "Advanced options" > "Interface options". 3. Select or clear the "Limit data infeed into the network" check box. Figure 5-54 Limit data infeed into the network PROFINET with STEP 7 V15 188 Function Manual, 12/2017, A5E03444486-AH Functions 5.6 PROFINET with performance upgrade 5.6 PROFINET with performance upgrade Performance upgrade The performance upgrade implements the application class "High Performance" of the PROFINET specification V2.3. The performance upgrade provides a series of measures that lead to the following improvements for PROFINET with IRT: ● Reduction of runtime delays in the IO devices ● Increase in the bandwidth for cyclic IO data ● Reduction of the bandwidth used for PROFINET frames ● Reduction of the send clocks The improvements achieved with the performance upgrade mean that you can operate your PROFINET IO system with more devices with the same send clock or the same number of devices with a shorter send clock. With PROFINET, it was previously possible to reach a send clock of 250 µs. With the performance upgrade, it is now possible to achieve isochronous send clocks of up to 125 µs with the fast forwarding, dynamic frame packing and fragmentation procedures, depending on the performance capability of the CPU (see Technical Specifications in the device manuals). With short send clocks, standard communication remains possible. The performance upgrade will help you to implement applications with high speed and send clock requirements. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 189 Functions 5.6 PROFINET with performance upgrade 5.6.1 Dynamic frame packing Dynamic frame packing Previously, individual PROFINET IO frames were sent for every PROFINET IO device. The performance upgrade uses the dynamic frame packing procedure that is based on the summation frame method. With the summation frame method, a frame contains the user data for neighboring devices on a line. With Dynamic Frame Packing, every IO device takes its data from the frame and forwards the rest. The frame is shortened from IO device to IO device. Dynamic frame packing improves the use of the bandwidth in a line topology. The following figure shows how Dynamic Frame Packing works based on the example of a frame containing the user data for 3 IO devices. ① ② ③ ④ ⑤ ⑥ The PROFINET IO frame contains the user data for all 3 IO devices (green, blue and orange). The PROFINET IO frame reaches the first IO device. The IO device takes its user data (green) from the frame and forwards the remaining frame. The PROFINET IO frame contains the user data for two IO devices (blue and orange). The PROFINET IO frame reaches the second IO device. The IO device takes its user data (blue) from the frame and forwards the remaining frame. The PROFINET IO frame contains the user data for one IO device (orange). The PROFINET IO frame reaches the last IO device. The IO device saves the entire frame including user data (orange). Figure 5-55 Dynamic Frame Packing (DFP) DFP groups Dynamic frame packing automatically groups IO devices that support the performance upgrade into DFP groups. To be grouped together in a DFP group. the IO devices must be located one after the other in a line and must have the same update time and watchdog time. As soon as a maximum frame size for the DFP group is exceeded or a maximum number of members for a DFP group is reached, Dynamic Frame Packing automatically opens a new DFP group. PROFINET with STEP 7 V15 190 Function Manual, 12/2017, A5E03444486-AH Functions 5.6 PROFINET with performance upgrade STEP 7 shows the DFP groups in "Domain management" > "Sync domains" > "Name of the sync domain" > "Device" in the "IO devices" box. Figure 5-56 Display of the DFP groups in STEP 7 Note Dynamic frame packing with high watchdog times If you set the parameter "Accepted update cycles without IO data" higher than 31, Dynamic Frame Packing does not place this IO device in a DFP group. 5.6.2 Fragmentation The transfer of a complete standard Ethernet frame with TCP/IP data takes up to 125 µs. This means that the cycle time for PROFINET IO data cannot be reduced by any desired amount. The performance upgrade uses the fragmentation procedure, which breaks down TCP/IP frames into sub-frames. These frame segments are transferred to the target device over multiple send clocks; there they are reassembled to the original TCP/IP frame. Fragmentation is a requirement for cycle times lower than 250 µs. In these short send clocks, you can use more bandwidth for cyclic IO data, since the fragments of the standard Ethernet frames use significantly less bandwidth than a complete standard Ethernet frame. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 191 Functions 5.6 PROFINET with performance upgrade The following figure shows how fragmentation works. ① ② ③ A standard Ethernet frame with TCP/IP data is up to 125 µs. During fragmentation, the standard Ethernet frame is divided into frame segments. The frame segments are divided into multiple short send clocks. Figure 5-57 Fragmentation Note The PROFINET IO interface of the IO controller supports fragmentation if all the ports except one are deactivated. 5.6.3 Fast forwarding To be able to decide whether a frame should be forwarded or used, a PROFINET IO device requires the frame ID. It previously took 1440 ns until the frame ID was present in the IO device. The performance upgrade uses the fast forwarding procedure in which the frame ID is located nearer the front of the frame. The throughput time in the device is reduced to 320 ns. With fast forwarding, the throughput time of the frame is reduced in your PROFINET IO system. This results in decisive performance advantages, particularly in line, ring and tree topologies. PROFINET with STEP 7 V15 192 Function Manual, 12/2017, A5E03444486-AH Functions 5.6 PROFINET with performance upgrade The figure below compares the throughput of a PROFINET IO frame in an IO device with and without fast forwarding. ① Start: • Both PROFINET frames reach the IO device. The IO devices start to check the frames for the frame ID ② After 320 ns: • Without fast forwarding: The IO device is still checking the PROFINET frame for the frame ID. • ③ With fast forwarding: The IO device receives the frame ID from the PROFINET frame and forwards the frame. After 1440 ns: • Without fast forwarding: The IO device receives the frame ID from the PROFINET frame and forwards the frame. • The PROFINET frame with fast forwarding is "ahead" of the PROFINET frame without fast forwarding. Figure 5-58 5.6.4 Fast forwarding Configuration of IRT with high performance High-end applications with IO communication require excellent performance in IO processing, for example in the control of wind turbines (converter control). To use IRT communication with the highest performance in your PROFINET IO system, enable the option "Make 'high performance' possible". When you enable the "Make 'high performance' possible" option, this has the following effects: ● You can set send clocks of 187.5 µs and 125 µs (for example CPU 1518-4 PN/DP) or 187.5 µs (for example CPU 1517-3 PN/DP), see Technical specifications in the CPU device manuals. ● You can set more bandwidth use for cyclic IO data. ● You can use the option "Allows the use of 'fast forwarding'". Requirements ● S7-1500 CPU as of firmware version V2.0 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 193 Functions 5.6 PROFINET with performance upgrade Enable the "Make 'high performance' possible" option. Follow these steps to activate the "Make 'high performance' possible" option: 1. Select the PROFINET IO system in the network view of STEP 7. 2. In the Inspector window, go to "Properties" > "General" > "PROFINET" > "Domain management" > "Sync domains" > "Name of the sync domain". 3. Enable the "Make 'high performance' possible" option. Figure 5-59 Activating high performance Using more bandwidth for cyclic IO data Requirement: The "Make 'high performance' possible" option is enabled. To set more bandwidth for cyclic IO data for your PROFINET IO system, follow these steps: 1. Select your IO system in the network view of STEP 7. 2. In the Inspector window, go to "Properties" > "General" > "PROFINET" > "Domain management" > "Sync domains" > "Name of the sync domain" > "Details". 3. In the drop-down list, select "Maximum 90% cyclic IO data. Focus on cyclic IO data". Figure 5-60 Using more bandwidth for cyclic IO data Note Bandwidth usage in isochronous mode If you operate your PROFINET IO system in isochronous mode, avoid using the setting for the bandwidth usage "Maximum 90% cyclic IO data. Focus on cyclic IO data." PROFINET with STEP 7 V15 194 Function Manual, 12/2017, A5E03444486-AH Functions 5.6 PROFINET with performance upgrade Setting low send clocks (example CPU 1518-4 PN/DP) Requirement: The "Make 'high performance' possible" option is enabled. 1. Select the PROFINET IO system in the network view of STEP 7. 2. In the Inspector window, go to "Properties" > "General" > "PROFINET" > "Domain management" > "Sync domains" > "Name of the sync domain". 3. Select the send clock for "Send clock" in the drop-down list. Figure 5-61 Setting low send clocks Requirements for the fragmentation process (example CPU 1518-4 PN/DP) If you use the following combinations for send clock and bandwidth settings, the devices in the IO system use the fragmentation process. ● Send clock cycle 125 µs: Always fragmentation irrespective of the bandwidth setting. ● Send clock cycle 187.5 µs: Fragmentation with the bandwidth settings "Maximum 50% cyclic IO data. Balanced proportion." and "Maximum 90% cyclic IO data. Focus on cyclic IO data." The PROFINET IO interface of the controller supports fragmentation if all the ports except one are deactivated. Optimizing port settings for low send clocks You can further optimize the bandwidth use in your PROFINET IO system by using cables with a short cable length (< 20 m) or a short signal delay (max. 0.12 µs) between the devices. To configure cables with a shorter length or signal delay in STEP 7, follow these steps: 1. Select the port in the topology view of STEP 7. 2. Navigate in the Inspector window to "Port interconnection" in the "Partner port" box. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 195 Functions 5.6 PROFINET with performance upgrade 3. Select the option "Cable length" or "Signal delay:". 4. Select the cable length or enter the signal delay. Figure 5-62 Optimizing port settings for low send clocks Allowing fast forwarding Requirements: ● The PROFINET IO device has to support the fast forwarding process so that the process can be used by the device. ● The "Make 'high performance' possible" option is enabled. ● The PROFINET IO interface supports fast forwarding if all the ports except one are deactivated. Follow these steps to allow fast forwarding: 1. Select the PROFINET IO system in the network view of STEP 7. 2. In the Inspector window, go to "Properties" > "General" > "PROFINET" > "Domain management" > "Sync domains" > "Name of the sync domain". 3. Enable the "Allows the use of ‘fast forwarding'" option. Figure 5-63 Allowing fast forwarding PROFINET with STEP 7 V15 196 Function Manual, 12/2017, A5E03444486-AH Functions 5.6 PROFINET with performance upgrade Note Fast forwarding and IPv6 The operation of fast forwarding in combination with IPv6 is not supported. As soon as an IO device in the subnet uses an IPv6 address, you must not activate "fast forwarding". 5.6.5 Sample configuration for IRT with high performance The figure below shows an example configuration with which you can achieve maximum performance. Port 1 of the X1 interface of the CPU is deactivated. Port 2 of the X1 interface and the ports of the interface modules on the bus use the following setting: Medium copper, cable length < 20 m or signal delay max. 0.12µs A programming device connection to the CPU can be established via the interfaces X2 and X3 of the CPU or via the free port at the end of the line. Figure 5-64 Example configuration for IRT with high performance Use the following settings for the Sync domain: ● Enable the "Make 'high performance' possible" option. ● Set the send clock to 125 µs. ● Enable the "Allows the use of ‘fast forwarding'" option. Standard Ethernet communication for IRT with high performance Standard Ethernet communication is still possible even in a PROFINET IO system with high performance. Keep in mind that you first arrange the IRT nodes, as seen from the IO controller, and arrange the standard Ethernet nodes at the end of the line. With a large volume of data through standard Ethernet communication, it makes sense to reduce the load on your network by separating standard Ethernet communication and cyclic real-time communication. Example: Use the interface X1 for the PROFINET IO communication and a different interface for the standard Ethernet communication. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 197 Functions 5.7 Isochronous mode 5.7 Isochronous mode 5.7.1 What is isochronous mode? Objectives of isochronous operation Assuming public transport were to operate at maximum speed while reducing stop times at the passenger terminals to absolute minimum, the last thing many potential passengers would notice of the departing contraption are its red tail lights. The overall travel time is, however, decided by the train, bus or underground-railway clock, because well adjusted timing is essential to a good service. This also applies to distributed automation engineering. Not only fast cycles but also the adaptation and synchronization of the individual cycles result in optimum throughput. Just-In-Time Figure 5-65 System cycle The high speed and reliable reaction time of a system operating in isochronous mode is based on the fact that all data are provided just-in-time. The constant bus cycle time PROFINET IO cycle beats the time here. PROFINET with STEP 7 V15 198 Function Manual, 12/2017, A5E03444486-AH Functions 5.7 Isochronous mode Advantages of isochronous mode The use of isochronous mode allows high-precision control. ● Optimized control ● Determinism ● Consistent (simultaneous) reading in of input data ● Consistent (simultaneous) output of output data 5.7.2 Use of isochronous mode With the "Isochronous mode" system property, measured values and process data can be acquired in a fixed system clock. The signal processing up to the switching-through to the "output terminal" occurs within the same system clock. Isochronous mode thus contributes to high-quality control and hence to greater manufacturing precision. With isochronous mode, the possible fluctuations of process response times are drastically reduced. The timeassured processing can be utilized to improve machine cycle times. In principle, isochronous mode is worthwhile whenever measured values must be acquired synchronously, movements must be coordinated, and process responses must be defined and simultaneously executed, as in the following example. There are thus numerous areas in which isochronous mode can be used. 5.7.3 Isochronous applications Example: Isochronous measurement at several measuring points Quality assurance requires precise measurement of dimensions within a camshaft production process. Figure 5-66 Measuring of camshafts PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 199 Functions 5.7 Isochronous mode Isochronous workflow When the isochronous mode property of the system is used, the measured value acquisition is clocked and occurs simultaneously at the various measuring points. The time required for measurement is reduced. Resultant workflow: ● Continuous machining of the camshaft ● Synchronous measurement of the camshaft positions and gradients within a continuous rotation. ● Machining of the next camshaft All camshaft positions and the corresponding measured values (red) are measured synchronously within a single rotation of the camshaft. This increases machine output and maintains or enhances precision of the measurement. 5.7.4 Time sequence of synchronization From reading-in of input data to outputting of output data The basic time sequence of all components involved in synchronization is explained in the following: ● Reading-in of input data in isochronous mode ● Transport of input data to the IO controller (CPU) via the PROFINET subnet ● Further processing in the isochronous application of the CPU ● Transport of output data to the outputting IO device via the PROFINET subnet ● Outputting of output data in isochronous mode T_DC TI TO Data cycle (Time_DataCycle) Time for reading in the input data Time for outputting the output data Figure 5-67 Time sequence of synchronization PROFINET with STEP 7 V15 200 Function Manual, 12/2017, A5E03444486-AH Functions 5.7 Isochronous mode The start of the I/O read cycle is advanced by the amount of a bias time TI in order to make all input data available for transfer on the PROFINET IO line at the start of the next PROFINET IO cycle. TI is the "flashlight" for the inputs; at this instant all synchronized inputs are read in. TI is necessary in order to compensate for analog-to-digital conversion, backplane bus times, and the like. The bias time TI can be configured by STEP 7 or by the user. We recommend automatically assigning the bias time TI of STEP 7. The PROFINET IO line transports the input data to the IO controller. The application can be started synchronized to the cycle, i.e., the isochronous mode interrupt OB is called after a parameterizable delay time. The user program in the isochronous mode interrupt OB decides the process reaction and provides the output data in time for the start of the next data cycle. The length of the data cycle is always configured by the user. TO is the compensation arising from the backplane bus and the digital-to-analog conversion within the IO device. TO is the "flashlight" for the outputs; at this instant the synchronized outputs are output. The time TO can be configured by STEP 7or by the user. We recommend automatically assigning the bias time To of STEP 7. Isochronous mode and non isochronous mode distributed I/O It is possible to combine isochronous mode distributed I/O with non isochronous mode distributed I/O on one IO controller. 5.7.5 Basics of Programming Programming in the isochronous mode interrupt OBs The isochronous part of the program is always programmed in the isochronous mode interrupt OBs OB 61 to OB 64. As the isochronous mode interrupts are processed with high priority, only the time-sensitive elements of the program should be processed in OB 6x. The isochronous mode interrupt is called with a configured delay time. Accessing isochronous I/O by calling system functions The isochronous I/O are updated exclusively by calling the "SYNC_PI" and "SYNC_PO" instructions and therefore in the corresponding process image partition. Note To prevent inconsistent data from being returned to OB6x, you should avoid using the "DPRD_DAT" and "DPWR_DAT" instructions (direct data access) in the isochronous mode OB. Direct access to the I/O areas returns current values of the process that do not, however, necessarily match the values supplied by "SYNC_PI" and "SYNC_PO". PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 201 Functions 5.7 Isochronous mode The "SYNC_PI" and "SYNC_PO" instructions can update the process image partition only within the permitted execution window. The execution window for the possible call of the "SYNC_PI" and "SYNC_PO" instructions stretches from the end of the cyclical data exchange on the PROFINET IO until the point in time before the end of T_DC at which the outputs can still be copied on time. The data exchange must be started within this time window. If the "SYNC_PI" and "SYNC_PO" instructions are not processed within the execution window, the system functions will indicate this with a corresponding error message. An image in which the execution window and the corresponding times are displayed can be found in the next section. Program execution models Depending on the order of the "SYNC_PI" and "SYNC_PO instructions in OB6x and the application cycle factor used, the program execution can be divided into two basic models: ● IPO model (read Inputs - Processing - write Outputs), CACF = 1 ● IPO model (read Inputs - Processing - write Outputs), CACF > 1 5.7.6 Program processing according to the IPO model with application cycle = 1 Characteristics of the IPO-model with application cycle factor = 1 The IPO model with application cycle factor = 1 is characterized by the fact that the execution of the I/O data is complete within one system clock cycle T_DC. The shortest response times are achieved with this model. PROFINET with STEP 7 V15 202 Function Manual, 12/2017, A5E03444486-AH Functions 5.7 Isochronous mode IPO model with application cycle factor = 1 With the IPO model with application cycle factor = 1, there is a constant execution time from the "input terminal" to the "output terminal" of TI + T_DC + TO. TI + 2×T_DC + TO can be guaranteed for the process response time. Figure 5-68 Program execution according to the IPO model with application cycle = 1 The figure shows the IPO model with the application cycle factor = 1 from acquisition through processing on the CPU to output of the process values. STEP 7 calculates the delay time or you can enter it yourself (see section Setting the application cycle and delay time (Page 208)). During this time, the read input data and the written output data is on its way on PROFINET IO. The delay time is set as a default to the start of the execution window. The isochronous user program in OB 6x begins with the "SYNC_PI" instruction and ends with the "SYNC_PO" instruction. The "SYNC_PI" and "SYNC_PO" instructions may only be processed within the execution window. The processing of the user program must be completed within the data cycle T_DC. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 203 Functions 5.7 Isochronous mode 5.7.7 Program execution according to the IPO model with application cycle > 1 Characteristics of the IPO-model with application cycle factor > 1 The IPO model with application cycle factor > 1 is an IPO model over multiple data cycles T_DC. In this case, it is an IPO model with an output delayed by one application cycle (OB6x). The input and processing take place in the same application clock cycle. Output is performed at the start of the next application clock cycle, directly before the next input. You call the "SYNC_PI" and "SYNC_PO" instructions in the execution window of the first data cycle T_DC of the application clock cycle (only available there with application cycle factor > 1.) The other user program execution in OB 6x then occurs after "SYNC_PO" and extends into the next data cycle or over the following data cycles T_DC. Figure 5-69 Program execution according to the IPO model with application cycle factor > 1 The figure shows the signals of the IPO model with application cycle factor = 2 over time from the acquisition through the processing on the IO controller to the output of the process values. STEP 7 calculates the delay time TM. During this time, the read input data and the written output data is on its way on PROFINET IO. The IPO model with application cycle factor > 1 is particularly ideal for large IO infrastructures with a comprehensive user program in the OB6x. With this model, longer calculation times are possible when executing the input data and obtaining the corresponding output data. With the IPO model with application cycle factor > 1, there is a constant execution time from the "input terminal" to the "output terminal" of TI + (application cycle factor + 1) x T_DC + TO. TI + (2 x application cycle factor + 1) x T_DC + TO can be guaranteed for the process response time. PROFINET with STEP 7 V15 204 Function Manual, 12/2017, A5E03444486-AH Functions 5.7 Isochronous mode 5.7.8 Configuring isochronous mode Introduction The configuring of isochronous mode for a module is described as IO device in the following based on the ET 200MP distributed I/O system. The procedure described also applies to other distributed I/O systems (e.g., ET 200S or ET 200SP). The IO controller is an S7-1500 CPU. Requirements ● The STEP 7 network view is open. ● A S7-1500 CPU has been placed (e.g., CPU 1516-3 PN/DP). ● An interface module IM 155-5 PN HF (ET 200MP) has been placed and networked with the CPU. ● All requirements for an IRT configuration are met, namely: – The ports of the CPU and the interface module are interconnected. – The RT class of the interface module is set to "IRT" (area "Advanced options > Real time settings > Synchronization"). – You have assigned the "sync master" and "sync slave" roles. Procedure To create an isochronous connection between the I/O and user program, follow these steps: 1. Select the "IM 155-5 PN HF" in the network view of STEP 7 and switch to the device view. 2. Insert an IO module that can be operated in isochronous mode (module with the extension "HF"). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 205 Functions 5.7 Isochronous mode 3. Go to the "I/O addresses" area in the Inspector window of the selected I/O module. Figure 5-70 Configuring isochronous mode in STEP 7 PROFINET with STEP 7 V15 206 Function Manual, 12/2017, A5E03444486-AH Functions 5.7 Isochronous mode 4. Make the following settings in the I/O addresses area: – Select the "Isochronous mode" option. – Select a process image partition, e.g., process image partition 1. – Click on the "Assigned organization block" in the drop-down list and click the "Add object" button, or select an already existing OB. Figure 5-71 Creating the organization block for programming isochronous mode A dialog box for selecting organization blocks opens. – Select the "Synchronous Cycle" OB and confirm the selection with "OK". In the case of automatic number assignment, OB 61 will be generated and opened. The "Isochronous mode" area is selected in the Inspector window, and you can continue directly with the setting of the application cycle and delay time and start the programming of the OB in the instruction section. 5. Add other IO devices as required in the network view and adapt the configuration and the isochronous mode settings. 6. To retrieve information about calculated bandwidths or to adapt the send clock, select the subnet and navigate to the corresponding area of the domain management in the Inspector window. Programming isochronous mode The user program must be set up accordingly in order to operate your plant in isochronous mode. To do this, you must create an isochronous mode interrupt OB (OB 6x) in an I/O module (see above). You access the isochronous I/O via a process image partition, i.e., the addresses of isochronous modules must be in a process image partition. You have to program accesses to the isochronous IO with the instructions SYNC_PI and SYNC_PO in the isochronous mode interrupt OB. With an application cycle = 1 you call the SYNC_PI instruction at the start of the isochronous mode interrupt OB, provided you have selected the automatic setting for the delay time. You call the instruction SYNC_PO at the end of the OB 6x. With an application cycle > 1 you first call the SYNC_PO instruction at the start of the isochronous mode interrupt OB, then the SYNC_PI instruction and subsequently the actual user program. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 207 Functions 5.7 Isochronous mode 5.7.9 Setting the application cycle and delay time Requirement ● You have created an isochronous mode configuration in STEP 7. ● You have created an isochronous mode interrupt OB. ● The isochronous mode interrupt OB is open. Setting the application cycle and delay time To set the application cycle for your isochronous mode application, follow these steps: 1. Open the "Properties" dialog associated with the relevant isochronous mode interrupt OB. 2. In the area navigation, click the "Isochronous mode" group . 3. Set the application cycle in "Application cycle (ms)". Open the drop-down list box and select the application cycle. The drop-down list box offers multiples of the PROFINET send cycle clock as possible values for the application cycle. The PROFINET send cycle clock is set to 2 ms in the following figure. Figure 5-72 Setting the application cycle PROFINET with STEP 7 V15 208 Function Manual, 12/2017, A5E03444486-AH Functions 5.7 Isochronous mode Setting the delay time STEP 7 sets the delay time automatically to the start of the execution window by default. As a result, the isochronous mode update of the process image partition automatically falls within the execution window of the application cycle. You can also set the delay time manually. A shorter delay time enables you to increase the processing time for your user program in the isochronous mode interrupt OB. If a manual setting is made, note that you must call the "SYNC_PI" and "SYNC_PO" instructions in the execution window of the application cycle. To set the delay time for your isochronous mode application, follow these steps: 1. Open the "Properties" dialog associated with the relevant isochronous mode interrupt OB. 2. In the area navigation, click the "Isochronous mode" group . 3. Clear the "Automatic setting" check box. 4. Enter your desired delay time in "Delay time (ms)". Figure 5-73 Setting the delay time PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 209 Functions 5.8 Device replacement without exchangeable medium 5.8 Device replacement without exchangeable medium Definition IO devices which have no slot for exchangeable medium (e.g. ET 200SP, ET 200MP) or IO devices which support the PROFINET functionality "Device replacement without exchangeable medium/PG" can be replaced without having an exchangeable medium with saved device names inserted and without having to assign the device name with the PG. The new IO device is given a device name by the IO controller and not by the exchangeable medium or the PG. To assign the device name, the IO controller uses the configured topology and the neighborhood relations established from the IO devices. Figure 5-74 Device replacement without exchangeable medium Note When you exchange a device, make sure that the PROFINET cable is again inserted into the correct port, as it is configured in STEP 7. Otherwise, the system will not run. Advantages With the Device replacement without exchangeable medium/PG PROFINET functionality, you can profit from the following advantages: ● After the replacement of the IO device, it automatically obtains its device name from the IO controller. You no longer have to assign device names with the PG or exchangeable medium. ● You can save on the storage medium for the IO device that replaces the removed one. ● Simple device name allocation with series machines that have the same configuration and set topology. It is no longer necessary to assign device names via exchangeable medium/PG. Which devices support device replacement without exchangeable medium? An overview of the devices that support the "Device replacement without exchangeable medium" function is provided in this FAQ (https://support.industry.siemens.com/cs/ww/en/view/36752540). PROFINET with STEP 7 V15 210 Function Manual, 12/2017, A5E03444486-AH Functions 5.8 Device replacement without exchangeable medium 5.8.1 Device replacement without exchangeable medium/PG function Neighborhood Neighborhood is the physical relationship between two ports of adjacent PROFINET devices. A PROFINET device is connected in this case through one of its ports over a physical Ethernet line to a specific port of the second PROFINET device in close proximity (neighbors). Both terminal devices, for example, IO controllers and IO devices with a port, and network components, for example, switches, IO controllers and IO devices with multiple ports, are considered PROFINET devices. Failure and replacement of an IO device The following example describes device replacement without exchangeable medium in the case of failure of an IO device. Figure 5-75 Example configuration of device replacement without exchangeable medium For the device replacement, the following information is available to the IO controller: PROFINET device Device alias Controller "port-001.Switch" Switch "port-002.Controller", "port-001.Press", "port-001.Pump" Press "port-002.Switch", "port-001.Mill" Mill "port-002.Press" Pump "port-004.Switch" The IO device with the device name "Mill" fails in this example: Requirement The PROFINET device replacing the removed one has no device name. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 211 Functions 5.8 Device replacement without exchangeable medium Principles of name assignment The failure of the "Mill" IO device is considered here. 1. The IO controller queries the device name of the replaced IO device. 2. The IO controller detects that the IO device with the device alias "port-002.Press" does not have a device name. 3. The IO controller assigns the device name "Mill" to the replaced IO device via the device alias "port-002.Press" of the failed IO devices. Note If you insert a device with the Device replacement without exchangeable medium/PG PROFINET functionality at a different location than the configuration, a different device name is then assigned to the device. Reset a wrongly inserted device to delivery state before you use it again. 5.8.2 Replacing an IO device without exchangeable medium Introduction Replacement of IO devices is sometimes frequently required in automation systems. The IO devices are generally assigned a device name by either inserting an exchangeable medium or via the programming device. The CPU identifies the IO device by using these device names. Under certain circumstances, replacing an IO device can be done without inserting an exchangeable medium or without the PG. PROFINET with STEP 7 V15 212 Function Manual, 12/2017, A5E03444486-AH Functions 5.8 Device replacement without exchangeable medium Requirements ● The topology of the PROFINET IO system with the respective IO devices must be configured. By configuring the topology, the neighbor relationships of all the PROFINET devices located in the PROFINET IO system are announced to the PROFINET IO system or the IO controller. From the neighbor relationships specified by the set topology and the actual neighbor relationships established by the real PROFINET devices, the IO controller can identify the replaced IO device without a name and assign to it the configured name and the IP address and then again list it in the user data traffic. ● The affected IO devices in the automation system must support device replacement without exchangeable medium. If the individual IO devices in the automation system do not support device replacement without exchangeable medium, a corresponding alarm is output for the IO device. Note Use only new IO devices as replacements or restore configured IO devices to their delivery state. Activating/deactivating device replacement without exchangeable medium The "Device replacement without exchangeable medium" function is activated in the IO controller by default. To deactivate device replacement without exchangeable medium, follow these steps: 1. In the device or network view of the STEP 7, select the PROFINET interface in the corresponding IO controller. 2. In the interface properties under "Advanced options > Interface options", clear the "Support device replacement without exchangeable medium" check box. To reactivate device replacement without exchangeable medium, you must select the "Support device replacement without exchangeable medium" check box again. 5.8.3 Permit overwriting of PROFINET device name With the option "Permit overwriting of PROFINET device names of all assigned IO devices", you can overwrite PROFINET device names of IO devices during startup of the CPU. This option reduces the effort during automatic commissioning, for example, when replacing a device. Requirements ● IO controller supports the "Permit overwriting of device names of all assigned IO devices" option, for example CPU 1215C DC/DC/DC as of firmware version 4.0 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 213 Functions 5.8 Device replacement without exchangeable medium How the "Permit overwriting of PROFINET device names of all assigned IO devices" option works The IO controller (CPU) can overwrite the PROFINET device names of IO devices in the IO system when the "Permit overwriting of PROFINET device names of all assigned IO devices" option is enabled. Multiple use IO systems can only be operated when this option is enabled. The IO controller checks prior to overwriting if the type of the IO device matches the configured type. If the option is not selected, the IO controller cannot overwrite the device names of the IO devices. In this case, you must manually assign the PROFINET device name on the IO device if the PROFINET device name changes in the configuration or when a device is replaced, or delete the device names of the IO devices prior to an automatic commissioning. Response during commissioning Select the option "Permit overwriting of PROFINET device names of all assigned IO devices" only if the following requirements are fulfilled: ● All the configured IO devices are available. ● All IO devices are wired correctly in accordance with the topology configuration. ● No IO device is jumpered. If configured IO devices are missing or are jumpered (partial commissioning), do not use the option. CAUTION Error at partial commissioning If device names are assigned incorrectly during partial commissioning or incorrect wiring, these have to be deleted manually after a correction of the wiring in order to attain correct assignment of the device names. PROFINET with STEP 7 V15 214 Function Manual, 12/2017, A5E03444486-AH Functions 5.8 Device replacement without exchangeable medium Behavior during operation After commissioning, you may exchange or jumper IO devices as long as the IO devices do not have a PROFINET device name that is used for a different IO device in the project. Otherwise, incorrect assignment of PROFINET device names in the neighborhood or further vicinity of the IO device can occur. WARNING Wrong PROFINET device name When the "Permit overwriting of PROFINET device names of all assigned IO devices" option is enabled, incorrectly connected devices can be assigned an incorrect PROFINET device name from the configuration. Depending on the connected I/O, there is risk of death, severe injuries or damage caused by malfunctions. To rule out any danger, check whether the suitable replacement device has been connected in case of a device replacement and whether the port interconnection matches the configured preset topology. Typical source of danger When replacing an IO device ("standard case"), it is almost guaranteed that the replaced device will be connected according to the configured port interconnection. The figure below shows a scenario whereby the connections of two identical PROFINET cables are swapped at two switch ports. Because the IO controller assigns the device names according to the preset topology, the incorrect connection of the devices has serious effects on the naming. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 215 Functions 5.8 Device replacement without exchangeable medium Due to the control of different actuators, the plant could become hazardous in this case. ① ② ③ ④ ⑤ Switch with connected PROFINET cables Device A, device name "IOD-1": controls motor 1 Device B, device name "IOD-10": controls motor 10 Device A controls motor 10! Device B controls motor 1! Procedure Proceed as follows to change the "Permit overwriting of PROFINET device names of all assigned IO devices" option: 1. Select the PROFINET interface of the CPU for which you want to change the option in the network view or in the device view. 2. Select the area "Advanced options", section "Interface options". 3. Change the option. PROFINET with STEP 7 V15 216 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects 5.9 Standard machine projects Introduction Standard machine projects are STEP 7 projects that use a set of innovative functions allowing simple configuration and commissioning of flexible automation solutions for standard machines or for machines with a modular structure. A hardware configuration consisting of an IO controller and any number of connected IO devices represents a "PROFINET IO system master". This master is configured with a maximum configuration based on a template from which various options can be derived for different standard machines, for example with different configuration variants of the IO system. Greater flexibility at all levels Standard machine projects have the following central characteristics: ● Different variants of a standard machine can be loaded from precisely one project with an engineered maximum configuration (IO system options). The standard machine project covers all variants (options) of the IO system. ● An IO system option can be integrated in an existing network locally using simple tools. Flexibility is provided in more ways than one: ● With suitable configuration, adaptation of the IP address parameters of the IO controller is possible locally using simple tools. This allows a standard machine to be integrated in different plants with little effort or to be included in a network several times. IO systems with this property are known as multiple use IO systems. ● With suitable configuration and programming, different setups of IO system options can be operated locally that differ in terms of the selection of IO devices used or in terms of the arrangement of the IO devices. Since the specific configuration of the IO system is controlled by the user program, this is known as configuration control for IO systems. ● Independently of the functions described above, with suitable configuration and programming, you can use different station options of central devices or distributed I/O devices in one project. The devices can be different in terms of the selection and arrangement of the modules. Since the concrete configuration of the station is controlled by the user program, this is also known as configuration control at the device layer. Application examples You can find application examples for configuration control at the device layer, configuration control for IO systems and multiple-use IO systems on the Internet (https://support.industry.siemens.com/cs/ww/en/view/29430270). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 217 Functions 5.9 Standard machine projects Additional information For more information on multiple use IO systems, refer to section Multiple use IO systems (Page 218). For more information on the configuration control for IO systems, refer to section Configuration control for IO systems (Page 226). For more information on configuration control, refer to the system manual S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792). 5.9.1 Multiple use IO systems 5.9.1.1 What you should know about multiple use IO systems Multiple use automation solutions For a flexible reusable automation solution as is the case with series machines, the following use cases are typical: ● The machine (and therefore also the PROFINET IO system) is used more than once by the customers. ● The machine is used in different plants by various customers. For this to be possible, the automation solution must meet the following requirements: ● A project (configuration and program) can be loaded on various machines of the same type without changes. ● Only a few easy adaptations need to be performed locally to integrate the machine into an existing network infrastructure. PROFINET with STEP 7 V15 218 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects The following figure shows how an automation solution with a multiple use IO system is loaded on different automation systems and then one automation system is adapted to the existing network infrastructure locally. ① ② Load configuration with multiple use IO system Set IP address and device name locally on the IO controller Figure 5-76 "Multiple use IO system" principle Principle The automation components for a machine include a PROFINET IO system, consisting of an IO controller (PROFINET interface of a CPU) and the IO devices assigned to it. With the "Multiple use IO system" setting for the IO system, you turn a STEP 7 project into a "Standard machine project". The "Multiple use IO system" setting triggers various settings and checks of the configuration by STEP 7. The settings ensure that the IO system is self-contained and there are no dependencies on components outside the IO system. Requirements ● STEP 7 as of V13 ● The IO controller supports the "Multiple use IO system" function, for example a CPU 1512SP-1 PN as of firmware version 1.6. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 219 Functions 5.9 Standard machine projects Rules The following rules apply to a multiple use IO system: ● No IO device can be configured as shared device. ● The ports of the devices must be interconnected. Devices for which no port interconnection is configured, for example, interface module IM 154-6 IWLAN (ET 200pro PN), cannot be operated with STEP 7 V13 as IO devices on a multiple use IO system. ● If an IO device in a multiple use IO system is an I-device (CPU as an "intelligent" IO device): – If the I-device has a lower-level IO system, this I-device cannot be connected to the same PROFINET interface as the higher-level IO controller. Note: If the I-device is configured using a PROFINET GSD, STEP 7 cannot check for compliance with this rule. In this case, you are responsible for ensuring compliance with the rule. ① ② I-device in multiple use IO system. The PROFINET interface is operated as IO device. No other IO system is connected here. A lower-level IO system on the I-device is connected to another PROFINET interface. Figure 5-77 Example configuration for "Multiple use IO system" with I-device – The PROFINET interface of the I-device must be set to "Parameter assignment of PN interface by higher-level controller". ● If MRP (Media Redundancy Protocol) is configured: – All IO devices on the multiple use IO system must belong to the same MRP domain. ● If IRT (Isochronous Real Time) is configured: – All IO devices in multiple use IO systems must belong to the same sync domain. – The sync domain must not include any other IO devices. ● IE/PB Links cannot be operated as an IO device in a multiple use IO system with STEP 7 V13. PROFINET with STEP 7 V15 220 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects Configuration You specify whether or not a configuration can be used multiple times in the properties of the IO system. All other parameter settings for the configured devices are then set automatically by STEP 7 and checked during compilation. Boundary conditions To prevent a standard machine project from having dependencies on other devices outside of the machine, observe the following: ● A standard machine project consists of an IO controller and the corresponding IO devices. You should therefore configure only one CPU as IO controller and the corresponding IO devices in the standard machine project. ● Do not use connection configured at both ends for the communication. Instead, use only a connection configured at one end or unspecified connections if necessary. Background: To configure the communication in a STEP 7 project, it is always possible to set the IP address parameters in the project. For multiple use IO systems, however, this strategy is not possible since the IP address parameters of the IO controller and the assigned IO devices are assigned locally. At the time of the configuration, the IP address parameters are therefore unknown. If you nevertheless want to configure communication with devices on PROFINET, for example with a central coordinator, you can only use communications mechanisms that allow dynamic assignment of the IP address parameters in the user program. Example: Open User Communication If, for example, the device is configured as an active end point (initiator of the connection), the IP address parameters can be stored, for example, in a data block. You then supply the data block with the currently valid IP address parameters during commissioning. For this dynamic type of IP address parameter assignment, there is no system support; in other words, if you change the configuration of the system, the IP address parameters are not automatically adapted. You will find a description of handling instructions for Open User Communication under this keyword in the STEP 7 online help. 5.9.1.2 Configuring multiple use IO systems Requirements ● STEP 7 as of V13 ● The IO controller supports the "Multiple use IO system" function, for example a CPU 1512SP-1 PN as of firmware version 1.6. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 221 Functions 5.9 Standard machine projects Procedure The configuration of a series machine using an S7-1500-CPU as an example is described below. To create a standard machine project, follow these steps: 1. Create a project. 2. Configure a CPU as the IO controller, for example a CPU 1518-4 PN/DP as of firmware version 1.5. 3. Configure the required IO devices and assign the IO devices to the IO controller. 4. Configure the port interconnection between the devices. 5. Select the IO system so that you can edit the properties in the inspector window. 6. Select the "Multiple use IO system" check box in the "General" area of the inspector window. Figure 5-78 Activate "Multiple use IO system" Result: The following settings are made by STEP 7: ● The device name of the IO controller (CPU) in the standard machine project is set to "PROFINET device name is set directly at the device". The IO controller (CPU) has no PROFINET device name initially. ● The IP protocol of the IO controller (CPU) is set to "IP address is set directly at the device". The CPU has no IP address initially. ● The "Support device replacement without exchangeable medium" option is selected automatically. This option enables automatic commissioning. A commissioning engineer does not have to assign device names to the IO devices locally. The IO controller assigns the device name and IP address to the IO devices based on the preset topology and other settings during startup. ● The device name of the IO devices is set to "Generate PROFINET device name automatically" (from the configured name of the IO device). ● The IP protocol of the IO devices is set to "IP address is set by the IO controller during runtime". The IO devices have no IP address initially. If an IO device is not a typical distributed I/O system (e.g., ET 200 systems), but rather another device such as an HMI device, change the option to "IP address is set directly at the device"; see below. ● The device number for the IO devices is automatically assigned and is used locally for making the IP address unique. PROFINET with STEP 7 V15 222 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects The option "Permit overwriting of PROFINET device name" must be selected (CPU parameters, properties of the PROFINET interface, Ethernet addresses area) so that the IO controller can adapt the device name later at the operator. This option is disabled by default. The following figure shows the above-described settings for the IP address and PROFINET device name. ① ② After the configuration is loaded from the standard machine project, the IO controller has no device name and no IP address. Following loading, the IO devices have a device name and a device number but no IP address. Figure 5-79 Settings for the IP address and the PROFINET device name How an IO device obtains an IP address locally Below, you will find an explanation of the "IP address is set by the IO controller during runtime" and "IP address is set directly at the device" options, which can generally be configured for a multiple use IO system. If you have set the "Multiple use IO system" option for the IO system, STEP 7 automatically sets the "IP address is set by the IO controller during runtime" option for the IO devices. In this case, the IO controller assigns the IO device an IP address that results from the locally assigned IP address of the IO controller (see next section). This option is appropriate if the IO device is a field device, e.g., ET 200MP, ET 200SP, ET 200AL, or another distributed I/O system. If the IO device is not a "standard" field device, for example, an HMI device for a Windows operating system, the "IP address is set by the IO controller during runtime" option described above does not work. In this case, choose the "IP address is set directly at the device" option. You must then assign the IP address to the device locally and take steps to ensure that this address is suitable for the IP addresses of the other IO devices and the IP address of the IO controller. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 223 Functions 5.9 Standard machine projects 5.9.1.3 Adapt multiple use IO systems locally A few steps are needed to adapt the machine that was loaded with the standard machine project. Only the device name and IP address of the IO controller must be adapted locally. The device names and IP addresses of the IO devices result from these adaptations. In this example, the effects of local settings are described for two specific machine modules. The local settings are possible, for example, with the CPU display and commissioning tools such as Primary Setup Tool (PST) or PRONETA. You do not need a programming device with STEP 7 to make these settings, even though it is possible to do so. Requirements ● The machine was loaded with a standard machine project (see Configuring multiple use IO systems (Page 221)). ● The display is ready for operation and the desired tool for assigning the IP address and device name is available (e.g., PST Tool, STEP 7). ● The ports of the IO controller and IO devices are interconnected according to the configuration. Procedure Observe the boundary conditions and instructions for commissioning an S7-1500. For more information on commissioning an S7-1500 CPU, refer to the system manual S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792). To adapt a standard machine locally, follow these steps: 1. Integrate the machine into the network. 2. Connect the device for assigning the IP address and device name to the CPU, for example a PG/PC with the appropriate software. 3. Assign the desired device name and IP address to the IO controller. 4. Start up the CPU. The IO controller then assigns the adapted PROFINET device name and a unique IP address to the IO devices. The following rules apply to the assignment: ● The device names of the IO devices are formed by chaining together the following name components, separated by a period: . ● The IP addresses of the IO devices result from the locally configured IP address of the associated IO controller and the device number (sum). PROFINET with STEP 7 V15 224 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects Note Make sure that duplicate IP addresses cannot be created on the subnet during the assignment. The IO controller does not assign a new IP address in this case. In the following figure, the device name "m1" and the IP address 192.168.1.10 have been assigned to the IO controller of the first machine. The device name "m2" and the IP address 192.168.1.20 has been assigned for the second machine. Refer to the figure for the resulting device names and IP addresses. ① ② Set device name and IP address on the IO controller After startup, the IO devices have an updated device name ( . ) and an adapted IP address (= + ) Figure 5-80 Example of the assignment of IP addresses and device names at "Multiple use IO system" See also Configuring multiple use IO systems (Page 221) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 225 Functions 5.9 Standard machine projects 5.9.2 Configuration control for IO systems 5.9.2.1 Information about configuration control of IO systems Configuration control of IO systems makes it possible to generate several concrete versions of a standard machine from a standard machine project. You are given the flexibility to vary the configuration of an IO system for a specific application as long as the real configuration can be derived from the set configuration. The configured configuration therefore represents the superset of all real configurations that can be derived from it. The following figure shows an example of how two IO systems with a different number of IO devices arise from one standard machine project. Figure 5-81 Example of configuration control for PROFINET IO systems In the following sections, you find a description of how to configure and program a PROFINET IO system to commission, for example, a standard machine on-site without using configuration software. PROFINET with STEP 7 V15 226 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects Concept The principle of configuration control is already known at the device level for the flexible use of submodules/modules ("option handling"). Different configurations can be derived from one engineering project both for central as well as for distributed I/O. With S7-1500 CPUs as of firmware version V1.7, this principle can also be applied at the IO system level. You have the option of omitting, adding or changing the order of stations (IO devices) of a PROFINET IO system in a specific plant. Configuration control for devices and configuration control for IO systems can be combined; the functions are independent of each other. It is possible to operate variants deviating from a maximum configuration of an IO system. In a standard machine project, you can prepare a kit of IO devices which can be flexibly customized for various configurations using configuration control. The following variations are available: ● Variation of the number of IO devices involved You include optional IO devices for the configuration control in the configuration by transferring a suitable data record with the required configuration in the user program. ● Variation of the order of IO devices involved You adapt the port interconnection of the IO devices to the topology being used by transferring a suitable data record with the required topology in the user program. The following figure shows how you serve two different configurations with an IO device marked as optional in the network view of STEP 7. ● Configuration without the optional IO device: In this case, you use the instruction "ReconfigIOSystem" to transfer a data record to the PROFINET interface containing the information that no optional IO device is to be included in the configuration. ● Configuration with the optional IO device: PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 227 Functions 5.9 Standard machine projects In this case, you use the instruction "ReconfigIOSystem" to transfer a data record to the PROFINET interface adding the optional IO device to the configuration. ① ② ③ Determined through parameter assignment: IO Device_2 is optional IO device Configuration without the optional IO device Configuration with the optional IO device Figure 5-82 Example configuration with "Optional IO device" and the associated configuration options Summary: The procedure in principle The following phases are distinguished when it comes to the implementation of a standard machine concept: 1. Engineering phase: Creating a standard machine project and loading into specific machine or plant: – Completely configuring all IO devices (options) ever required in a specific machine or plant – Configuring as optional those IO devices that will be omitted in specific machines or plants – Configuring the interconnection of ports with respect to various arrangements of IO devices – Preparing user program (see Configuring flexible order of IO devices (Page 236)) with the possibility of selecting on-site the actually existing configuration via switch or HMI device 2. Commissioning phase: Preparing specific machine or plant for operation: – Integrating machine or plant in the on-site network (see Adapt multiple use IO systems locally (Page 224)) – Selecting the currently existing configuration of the IO system via configured option PROFINET with STEP 7 V15 228 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects 5.9.2.2 Configuring IO devices as optional Requirements ● IO controller supports configuration control for IO systems, for example CPU 1516-3 PN/DP as of firmware version 1.7 ● STEP 7 V13 SP1 or higher ● The rules (Page 241) for the establishment and operation of a standard machine project have been considered. Procedure To configure an IO device as optional IO device, proceed as follows: 1. Create a project. 2. Configure an S7-1500 CPU firmware version V1.7 or higher as IO controller. 3. Configure the required IO devices and assign the IO devices to the IO controller. 4. Configure the port interconnection between the devices. Note A port interconnection between the devices of the IO system is mandatory for IO systems to be customized with the user program. Otherwise, no order would be defined for the interconnected IO devices. The following settings are possible for the partner port: • Specific partner port of an IO device (selection via the "Partner port" drop-down list in the port properties or interconnection with drag-and-drop in the topology view) • "Setting partner port by user program" (selection via the "Partner port" drop-down list in the port properties). 5. Select the IO device you want to mark as optional. 6. Select the area "PROFINET interface [X1]" > Advanced options". 7. Enable the "Optional IO device" option. 8. Repeat steps 5 to 7 for all IO devices to be configured as optional. 9. Load the configuration onto the CPU. Figure 5-83 Configure the IO device as an optional IO device PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 229 Functions 5.9 Standard machine projects Result: Once this configuration is loaded, the system behavior is as follows: ● The CPU is prepared for the configuration control of the IO system. ● All IO devices are disabled. ● Irrespective of whether you customize the configuration with the user program (adding optional IO devices) or make no changes to the loaded configuration: You must call the instruction "ReconfigIOSystem" in the user program and notify the current configuration to the system! The system will not be operational without calling the instruction "ReconfigIOSystem". For further information on the proceeding see Enabling optional IO devices in the program (Page 230). Fast parameter assignment in the "IO communication" table You can also specify whether or not an IO device is optional in the "IO communication" tab. In an additional "Optional IO device" column, a selectable check box is available for each IO device that indicates whether or not an IO device is optional. Here, you can adjust the setting centrally. 5.9.2.3 Enabling optional IO devices in the program Requirements ● IO controller supports configuration control for IO systems, for example CPU 1516-3 PN/DP as of firmware version 1.7 ● STEP 7 V13 SP1 ● At least one IO device was configured as optional IO device. ● The rules (Page 241) for the establishment and operation of a standard machine project have been considered. Procedure Observe the information on and rules for commissioning in the documentation for SIMATIC S7-1500, for the ET 200SP CPUs and for the CPU 1516pro-2 PN. The following description of the proceeding only includes steps required to understand the program-controlled activation of an optional IO device. To activate or deactivate IO devices, follow these steps: 1. Create a data record "CTRLREC" for the instruction "ReconfigIOSystem". You can find information on the structure of the data record in the STEP 7 online help. PROFINET with STEP 7 V15 230 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects 2. Call the instruction "ReconfigIOSystem" and select MODE 1 to deactivate all IO devices. If you set the CPU to STOP or POWER OFF state in order to modify the plant in this status (for example to add an optional IO device), explicit deactivation using "ReconfigIOSystem" with mode 1 is not necessary. In this case, i.e. following a STOPRUN transition and following a POWER-OFF > POWER-ON transition, all IO devices are deactivated automatically. 3. When you have brought the plant to a safe status that allows restructuring without any danger: Put the plant together according to your intended application. Add the required optional IO devices at the points at which you planned this in the configuration (observe the order!) or remove optional IO devices that you no longer require. 4. Network the IO devices. 5. Startup the S7-1500 system and call again the instruction "ReconfigIOSystem". Select MODE 2 to transfer the data record CTRLREC. 6. Following successful transfer of the data record, call again the instruction "ReconfigIOSystem". Select MODE 3 to activate all IO devices forming part of the current configuration. Result: The CPU activates the following IO devices: – All IO devices that you have not set as optional IO devices. – All optional IO devices listed in the control data record (CTRLREC). The following IO devices remain disabled: – Docking units (IO devices changing during operation). – Optional IO devices that are not listed in the control data record. Note Call the instruction "ReconfigIOSystem" for all values of the parameter MODE with the same control data record (CTRLREC)! If you use different data records for the values of the MODE parameter, this results in an inconsistent customization of the configuration and thus to rather incomprehensible error messages. Example: Data record structure for the activation of an IO device The IO device "IO-Device_2" is to be activated as the only IO device in the user program. To do this, you only require the hardware identifier of "IO-Device_2". Recommendation: Use the system constants of the hardware identifiers instead of the absolute values as shown in this example. With this procedure, the content of the DB is not influenced by changes to the hardware identifiers as the result of changes to the configuration. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 231 Functions 5.9 Standard machine projects The data record is to be stored in a data block and to be transmitted to the PROFINET interface of the IO controller in the user program using the instruction "ReconfigIOSystem". ① ② IO device_2 is configured as optional IO device. Once the data record is transmitted and the configuration is activated using the instruction "ReconfigIOSystem" IO device_2 is included in the configuration and participates in the data exchange with the IO controller. Figure 5-84 Example: Activating an optional IO device Creating data block In this example, the control data record is created in a data block. The data block is structured as follows: Line 2: Array definition: Array of type Word with 4 elements. Array of Word is permitted as the data type. Line 3: Version of the data record (currently: V1.0). Line 4: Number of optional IO devices to be activated (here: 1). Line 5: List of the hardware identifiers of the IO devices, inserted here as system constants. Line 6: Number of port interconnections that are set in the user program (here: 0). Line 7: Additional data records (optional) Figure 5-85 Data block with control records PROFINET with STEP 7 V15 232 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects Parameter MODE of instruction "ReconfigIOSystem" You control how the "ReconfigIOSystem" instruction works with the MODE parameter. The following values are possible for the MODE input parameter: MODE Description 1 All IO devices of the IO system can be disabled by calling the instruction with MODE 1. The "ReconfigIOSystem" instruction uses the "D_ACT_DP" instruction internally. "ReconfigIOSystem" returns errors that are detected by D_ACT_DP in the following output parameters: • STATUS (error code) • ERR_INFO (hardware identifier of the IO device causing the error). In STATUS and ERR_INFO, the CPU enters the last determined error/HW identifier and in so doing overwrites an existing error code. For this reason, additional errors can be present besides the entered error. For controlling the actual configuration of the IO system, the instruction transfers the data record to the PROFINET interface, which is addressed with LADDR block parameter (HW identifier of the PROFINET interface). All non-optional IO devices in the IO system and optional IO devices that are listed in the control data record CTRLREC are enabled. The optional IO devices that are not listed in the CTRLREC data record remain disabled. If IO devices that are part of docking units (alternating IO devices in operation) are listed in the CTRLREC control data record, the PN IO system reacts as follows: 2 3 • IO devices of the docking units remain disabled when ReconfigIOSystem is called with MODE 3. This reaction corresponds to the reaction of a configuration without configurationcontrolled IO devices. IO devices of docking units are disabled by default and must be enabled in the user program. For more information on docking units, refer to the section Docking systems (Page 246). Rules for the call sequence of "ReconfigIOSystem" ● Always supply the instruction "ReconfigIOSystem" with the same control data record (CTRLREC input parameter)! ● Call sequence following POWER OFF -> POWER ON transition: – ReconfigIOSystem call with MODE 1 (optional). – ReconfigIOSystem call with MODE 2 (mandatory, even without previous reconfiguration!). – ReconfigIOSystem call with MODE 3 (mandatory). ● Call sequence following STOP > RUN transition: – ReconfigIOSystem call with MODE 1 (optional). – ReconfigIOSystem call with MODE 2 (mandatory, even when configuration was modified in STOP state). Otherwise not required). – ReconfigIOSystem call with MODE 3 (mandatory). ● Call sequence for reconfiguration in RUN state: – ReconfigIOSystem call with MODE 1 (mandatory). – ReconfigIOSystem call with MODE 2 (mandatory). – ReconfigIOSystem call with MODE 3 (mandatory). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 233 Functions 5.9 Standard machine projects Explanations and recommendations concerning the rules ● If you do not list an IO device to be configured as optional IO device in the control data record or data block resp. this IO device does not form part of the configuration and does not take part in data exchange with the CPU. ● If you do not activate any optional IO device at all and work with the loaded configuration without reconfiguration, you still have to follow the proceeding described in the above section and transmit the control data record to the CPU. The control data record has the simple structure with the following tags: – Version (High Byte =1, Low Byte = 0) – Number of optional devices to be activated = 0 – Number of port interconnections that are set in the user program = 0 ● Following a STOP > RUN transition and following a POWER-OFF > POWER-ON transition, all IO devices are deactivated automatically. For this reason, no ReconfigIOSystem call with MODE 1 is required for configuration control to function properly. If you use your project as a universally valid sample for programming the configuration control, we still recommend to perform the ReconfigIOSystem call with MODE 1 prior to any reconfiguration. This way, the sample can also be used for reconfigurations in RUN mode. ● Commissioning extensive I/O systems (more than 8 optional IO devices) while using IRT at the same time: PROFINET with STEP 7 V15 234 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects To keep the startup times short when activating the optional IO devices (ReconfigIOSystem, mode 3), note the following tip: Check the device numbers of the IO devices. The device numbers should follow the topological interconnection starting at the IO controller in ascending order. The further an IO device is from the IO controller topologically, in other words the more IO devices there are between the IO controller and the IO device in question, the higher the device number should be. You set the device numbers in the "Ethernet addresses - PROFINET" area in the Inspector window with the PROFINET interface selected. Example of the assignment of device numbers with a linear topology: Figure 5-86 Example: Device numbers in a line topology ● The CPU processes the instruction "ReconfigIOSystem" to transfer the control data record asynchronously. For this reason, you must call "ReconfigIOSystem" in a loop repeatedly when calling the instruction in the startup program until the output parameter "BUSY" or "DONE" indicate that the data record has been transferred. Tip: To program the loop, use the SCL programming language with the instruction REPEAT ... UNTIL. REPEAT "ReconfigIOSystem"(REQ := "start_config_ctrl", MODE := 1, LADDR := 64, CTRLREC := "myCTRLREC".ArrMachineConfig0, DONE => "conf_DONE", BUSY => "conf_BUSY", ERROR => "conf_ERROR", STATUS => "conf_STATUS"); UNTIL NOT "conf_BUSY" END_REPEAT; Additional information For information on the basic structure of the data record and on using the instruction "ReconfigIOSystem" see the STEP 7 online help. See also Configuring IO devices as optional (Page 229) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 235 Functions 5.9 Standard machine projects 5.9.2.4 Configuring flexible order of IO devices The following section shows how you can create the conditions required to change the order of IO devices in a PROFINET IO system. This function is also supported with optional IO devices. For simplicity, a maximum configuration without optional IO devices is shown below. Concept A typical application for a standard machine project consists of composing an entire plant from a set of various plant units which only differ with respect to the different arrangement of the units, e.g. in the case of transport systems. Each plant unit consists of a functional unit of mechanics (rails or conveyor belts) and electrics (power supply, IO device with IO modules, sensors, actuators, motors, PROFINET port for data exchange with central control ...). The following figure shows how, simply by exchanging two rail segments, a new transport system is created that is adapted with an upstream points to the local conditions. Figure 5-87 Example: Changing the arrangement of IO devices From the automation viewpoint, no change in the project is required for the flexible adjustment of the PROFINET configuration. The order of the IO devices is determined by the port interconnection. For each IO device, you define in the port properties the partner port and thus the neighboring device connected at the respective local port. If the partner port is to be defined by the user program, the option "Partner set by user program" is to be selected as partner port. PROFINET with STEP 7 V15 236 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects The figure below shows the initial configuration of the transport system shown above, which is to permit the order of the connected IO devices to be changed via the user program. In the example, the order of IO-Device_2 and IO-Device_3 is to be controlled via the user program. Figure 5-88 Example configuration: Configuring flexible order of IO devices To determine how the partner port settings are to be selected, you must note for each device and each port of a device which partner can be interconnected. ● If the partner is always the same in the different configurations provided, you select the partner port for this partner. ● If the partners vary in the different configurations, you select "Setting partner by user program". For the example in the figure above, the following port settings result: Device Local port Partner port setting Explanation PLC_1 p1 p1 (IO device_1) Partner of PLC_1 at port 1 is IO device_1 (always) IO device_1 p1 p1 (PLC_1) Partner of IO device_1 at port 1 is PLC_1 (always) IO device_1 p2 Partner is set by user program Partner of IO device_1 at port 2 is either IO device_2 or IO device_3 => Setting partner by user program IO device_2 p1 Partner is set by user program Partner of IO device_2 at port 1 is either IO device_1 or IO device_3 => Setting partner by user program IO device_2 p2 Partner is set by user program Partner of IO device_2 at port 2 is either IO device_3 or IO device_4 => Setting partner by user program IO device_3 p1 Partner is set by user program Partner of IO device_3 at port 1 is either IO device_2 or IO device_1 => Setting partner by user program IO device_3 p2 Partner is set by user program Partner of IO device_3 at port 2 is either IO device_4 or IO device_2 => Setting partner by user program IO device_4 p1 Partner is set by user program Partner of IO device_4 at port 1 is either IO device_3 or IO device_2 => Setting partner by user program IO device_4 p2 Any partner No partner planned at port 2 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 237 Functions 5.9 Standard machine projects Requirements ● IO controller supports configuration control for IO systems, for example CPU 1515-2 PN as of firmware version 1.7 ● STEP 7 V13 SP1 or higher ● The rules (Page 241) for the establishment and operation of a standard machine project have been considered. Procedure To set the partner port for a program controlled interconnection, proceed as follows: 1. Select the PROFINET interface of the device (IO controller or IO device) whose port you want to set. 2. In the properties of the PROFINET interface, select the area "Port interconnection" (Extended options > Port [...] > Port interconnection). 3. From the drop-down list, select "Setting partner by user program" as partner port. 4. Repeat steps 1 to 3 for each port to be interconnected via the user program. See also Customizing arrangement of IO devices in the program (Page 238) 5.9.2.5 Customizing arrangement of IO devices in the program Requirements ● IO controller supports configuration control for IO systems, for example CPU 1516pro-2 PN as of firmware version 1.7 as an IO controller ● STEP 7 V13 SP1 ● At least one partner port was configured as "Partner set by user program". ● The rules (Page 241) for the establishment and operation of a standard machine project have been considered. Procedure The proceedings corresponds to the proceeding for activating optional IO devices. Only the structure of the data record must be extended for the program-controlled assignment of the ports. The extension is described in the following sections. PROFINET with STEP 7 V15 238 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects Example: Data record structure for the assignment of partner ports For the data record structure, you need the HW identifications of the ports. The data record is to be stored in a data block and to be transmitted to the PROFINET interface of the IO controller in the user program using the instruction "ReconfigIOSystem". As the input parameter RECORD of the instruction "ReconfigIOSystem" is of the VARIANT data type, you first have to create a data type for the data block. In the following sections, you find a description of the structure of the PLC data type as well as of the structure of the data block based on this type. Selecting derived configuration For the following selected configuration it is shown below what the data record must look like so that the IO devices are interconnected in the planned order by the user program. Figure 5-89 Example configuration: Customizing arrangement of IO devices in the user program This example is based on the flexible configuration from the previous section (Page 236) with the settings for the respective partner ports described there. The partner ports in the specific derived configuration have been defined so that it is possible to name the HW identifications of the ports involved. The following table only contains those devices whose ports can be defined by the user program. Only these devices are relevant for the data record structure. Device Local port Partner port setting IO device_1 p2 = Port 2 Partner is set by user HW identifier: 251 program Port 1 of IO device_3 IO device_2 p1 = Port 1 Partner is set by user HW identifier: 281 program Port 2 of IO device_3 HW identifier: 291 IO device_2 p2 = Port 2 Port 1 of IO device_4 Partner is set by user HW identifier: 311 program Partner port of the selected configuration HW identifier: 261 HW identifier: 321 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 239 Functions 5.9 Standard machine projects Creating data block For the derived configuration, the structure of the data block "DB-IO-SYSTEM-PortInterconnections" is explained as an example. This data block is used when calling the instruction "ReconfigIOSystem" at input parameter "CTRLREC". Instead of the absolute values for the hardware identifiers of the ports, the system constants of the hardware identifiers are used here. The data block is structured as follows: Line 2: Declaration of an Array of Word (only this data type is possible). Line 3: Version of the control data record: V1.0. Line 4: Number of optional IO devices: 0. Line 5: Number of specified port interconnections: 3. Line 6: Port interconnection 1, local port. Line 7: Port interconnection 1, partner port. Line 8: Port interconnection 2, local port. Line 9: Port interconnection 2, partner port Line 10: Port interconnection 3, local port. Line 11: Port interconnection 3, partner port. Figure 5-90 Data block with data record for port interconnections Interconnection not listed in data block If the partner port was configured as "Setting partner by user program" in the port properties and this port is not listed in the data record or data block resp., then the CPU sets this port to the setting "any partner". If no data record is transmitted at all, the CPU sets this "any partner" setting for all program-controlled assignments. Additional information For information on the basic structure of the data record and on using the instruction "ReconfigIOSystem" see the STEP 7 online help. PROFINET with STEP 7 V15 240 Function Manual, 12/2017, A5E03444486-AH Functions 5.9 Standard machine projects 5.9.2.6 System behavior and rules Below, you find a description of how an IO system whose configuration is controlled by the user program behaves in operation. In addition, rules and restrictions are listed here which must be considered when configuring the maximum structure of the configuration in a standard machine project. System behavior ● System diagnostics: If an optional IO device is deactivated, the IO device is displayed as "deactivated" from the system diagnostics viewpoint (online view or Online & Diagnostics). ● Topology view: Offline view: As configured. No interconnection is shown for ports with partner ports configured as "Setting partner by user program". Online view: Ports and interconnections with deactivated IO devices are shown in a different shade of green as error-free ports and interconnections of activated IO devices. ● Representation in the Web server: The names of devices are shown as configured (Properties > General > Project information). The assigned PROFINET device name for the CPU is shown on the "Communication" website, at the "Parameter" tab. IP address parameters: Currently assigned IP address parameters are shown on the site "Module state". Topology: The current topology resulting from any customizations via user program is shown in the Web server. IO devices configured as optional are shown as "deactivated" IO devices in the Web server. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 241 Functions 5.9 Standard machine projects Rules The rules for standard machine projects as described here (Page 218) apply. For configuration-controlled IO systems, the following additional rules apply: ● When configuring MRP (Media Redundancy Protocol): The ports configured as ring ports must not be interlinked via user program. However, devices with ring ports (devices of an MRP domain) can be optional IO devices. ● When configuring docking stations (= IO devices changing during operation): Neither the docking station nor the first IO device of a docking unit may be optional IO devices. The ports of the docking units must not be interlinked via user program. ● When configuring IRT: The order of synchronized IO devices ("IRT devices") must be defined by the configuration and must not be changed in the different variants of a standard machine. For this reason, the ports of the IRT devices must not be interlinked via user program. However, you have the possibility to configure IRT devices primarily as optional IO devices. You also have the option to interconnect, by user program, RT devices that are, for example, separated from this line by a switchport (see figure). Figure 5-91 Example: Configuration control for IO systems with separated RT device PROFINET with STEP 7 V15 242 Function Manual, 12/2017, A5E03444486-AH Functions 5.10 Saving energy with PROFIenergy 5.10 Saving energy with PROFIenergy Saving energy with PROFIenergy PROFIenergy is a PROFINET-based data interface for switching off consumers centrally and with full coordination during pause times regardless of the manufacturer or device type. Through this, the process should only be provided with the energy that is absolutely required. The majority of the energy is saved by the process; the PROFINET device itself only contributes a few watts of savings potential. Figure 5-92 Energy savings during pauses with PROFIenergy Basic information In order to use the PROFIenergy functionality, the existing IO controller has to be "upgraded" to a so-called "PROFIenergy controller" by means of a function block in the PROFINET IO system and at least one PROFIenergy-capable IO device ("PROFIenergy device") has to exist. The PROFIenergy commands (for example to start or end a pause) are sent by the "PROFIenergy controller" to the individual "PROFIenergy devices". Each "PROFIenergy device" decides individually how it responds to the PROFIenergy command (response is device- and manufacturer-specific). No additional hardware is needed; the PROFIenergy commands are directly interpreted by the PROFINET devices. Principle of operation At the beginning and end of pauses, the system manager enables or disables the pause function of the system; then the IO controller sends the PROFIenergy command "Start_Pause"/"End_Pause" to the PROFINET devices. The device interprets the contents of the PROFIenergy command and switches off or back on. Through other PROFIenergy functions, device information can be accessed during pauses. The user can use this information in order to optimally time the transfer of the "Start_Pause"/"End_Pause" command. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 243 Functions 5.10 Saving energy with PROFIenergy PROFIenergy instructions for IO controllers Two instructions are needed for controlling and monitoring the PROFIenergy functions. The instruction PE_START_END allows you to easily activate and deactivate the idle state of PROFINET devices. This occurs by means of an incoming edge or outgoing edge. The instruction PE_START_END provides a simple interface for implementing the PROFIenergy commands Start_Pause and End_Pause. The instruction PE_CMD allows you to transmit all PROFIenergy commands, including Start_Pause and End_Pause. The other commands can be used, for example, to query the current status of the PROFINET device or the behavior during the pauses. The instruction PE_CMD is a convenient means for handling all PROFIenergy functions. PROFIenergy instruction for I-devices The instruction PE_I_DEV allows you to also implement PROFIenergy on I-devices. The instruction receives PROFIenergy commands on the I-device and forwards these to the user program for execution. After executing the command, the user program calls the PE_I_DEV instruction again in order to send the acknowledgment to the IO controller. For these replies, each command offers you a helper instruction that supplies the reply data to the instruction. The instructions can be found in the "Instructions" task card of the STEP 7 program editor. Configuration and programming The functions can be comfortably integrated into existing systems. No configuration is required for the use of PROFIenergy. However, amendments to the user program are required: ● Before the "Start_Pause" command, you must ensure that your system is brought into a condition that is suitable for a pause. ● A sequential control system for the beginning of the pause of the devices and for the punctual restarting of the device on break must be programmed (depending on the required startup times that the respective PROFINET device demands). ● The error messages of the PE_CMD instruction must be evaluated, and the required reaction must be programmed (for example, cancellation or continuation of further commands on lower-level PROFINET devices). Note In the case of the ET 200S distributed I/O system, you have to configure the application of PROFIenergy in STEP 7. You configure PROFIenergy by selecting the "Use energy saving for this potential group" check box in the PM-E DC24V/8A RO power module. If you want to use PROFIenergy for an I-device, you have to configure this in STEP 7. Information about configuring PROFIenergy for an I-device is available in the section Configuring PROFIenergy with I-devices (Page 136). PROFINET with STEP 7 V15 244 Function Manual, 12/2017, A5E03444486-AH Functions 5.10 Saving energy with PROFIenergy Application examples ● SIMATIC S7 library for simple configuration of PROFIenergy. The application example is available here (https://support.industry.siemens.com/cs/ww/en/view/109478388). ● Application guide for implementation of shutdown concepts with PROFIenergy. The application example is available here (https://support.industry.siemens.com/cs/ww/en/view/96837137). ● Saving energy with SIMATIC S7 PROFIenergy with I-device The application example is available here (https://support.industry.siemens.com/cs/ww/en/view/41986454). PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 245 Functions 5.11 Docking systems 5.11 Docking systems Using alternating IO devices ("alternating partners") during operation in a docking station The following figure shows an automation cell with a docking station and several docking units. Figure 5-93 Alternating IO devices (partner ports) in a docking system Area of application for alternating IO devices during operation You can use the PROFINET function "Alternating IO devices during operation" ("alternating partners"), for the tool changeover for robots, for example. Typical tools include: ● Welding guns ● Positioning tools for manufacturing parts PROFINET with STEP 7 V15 246 Function Manual, 12/2017, A5E03444486-AH Functions 5.11 Docking systems Requirements for interconnecting alternating partner ports during operation You can interconnect IO devices with alternating partner ports during operation in the following situations: ● The alternating IO device (docking unit) has no IRT communication configured. ● The PROFINET interface is connected to the Ethernet subnet. ● The PROFINET devices support topology configuration. ● The IO controller, the alternating IO devices (docking unit) and the switch (docking station) on which the alternating IO devices are to be operated support this feature. Note Unique IP address Each docking unit of a docking system must be configured with a unique IP address in a shared project and operated on the same IO controller as all other docking units of the system. Applicative conditions The following points should be observed when implementing a docking system with alternating IO devices during operation: ● The IO devices of all docking units must be deactivated by default in the configuration. ● At any time, only one docking unit can be active, i.e., only the IO devices of one docking unit can be activated. All IO devices of other docking units must be deactivated or become deactivated before the IO devices of a docking unit can be activated. You activate an IO device with the "D_ACT_DP" instruction. ● A physical connection to this docking unit and its IO devices must be created in order to activate a docking unit. The IO devices are then switched on (power on). At the same time, all the IO devices of this docking unit must be activated in the user program with the "D_ACT_DP" instruction. Note Automatic deactivation in "Startup" mode of the CPU If the CPU is in "Startup" mode, IO devices of a docking system that alternate during operation are deactivated automatically. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 247 Functions 5.11 Docking systems ● After the feedback "IO device activated", you can access the IO device by means of direct I/O access. ● Call the "D_ACT_DP" instruction to activate and deactivate the IO device as close as possible to the start of the OB 1 cycle. Note Number of alternating IO devices during operation ("alternating partner port") - number of docking units If you wish to achieve the shortest possible tool changeover times, you must observe the following points that are dependent on the CPU or the CP that is being used: • Only those IO devices that have been configured with the PROFINET function "Prioritized startup" can start up in an optimized fashion. The number of IO devices with configuration for this PROFINET function is restricted. • Only a limited number of IO devices can be activated at the same time. This number depends on the available "D_ACT_DP" resources. A docking unit should not contain more than the corresponding number of IO devices. If more IO devices are operated in a docking unit, the IO devices must be activated one after the other, which takes correspondingly longer. Example: An S7-CPU 1516-3 PN/DP can operate a maximum of 32 IO devices with prioritized startup and can simultaneously activate 8 IO devices by means of "D_ACT_DP". Therefore, for a scheduled optimum use, a docking unit should include no more than 8 IO devices and no more than 32 IO devices should be used in all the alternating docking units. 5.11.1 Configuring docking systems Configuring docking systems The possible connections to the individual IO devices must be configured in STEP 7. Procedure in STEP 7 1. Configure your system as usual, but do not yet configure the topological interconnections of the individual PROFINET devices. 2. Navigate to the "Topology view" tab. 3. Select the port which you want to operate with alternating partners during operation. 4. Navigate to the "Properties" tab of the inspector window and select "Port interconnection" in the area navigation. PROFINET with STEP 7 V15 248 Function Manual, 12/2017, A5E03444486-AH Functions 5.11 Docking systems 5. Under "Partner port", select the "Alternative partners" option. 6. Select the desired partner ports: To do this, click " Advanced options > Interface options". 4. Select the "Prioritized startup" check box. Figure 5-97 Configuring prioritized startup in STEP 7 5. Download the configuration to the IO controller. Note Prioritized startup after a startup for the first time A prioritized startup of the IO device is always available to you after the first configuration of this IO device in the very first startup of the PROFINET IO system. Even in the case of spare parts or a reset to factory settings, the first startup is a standard startup for the respective configured IO devices. Note Number of IO devices (distributed I/O) with prioritized startup You can only start up a maximum number of IO devices with the "Prioritized startup" PROFINET functionality within one PROFINET IO system. This maximum number depends on the IO controller used. PROFINET with STEP 7 V15 254 Function Manual, 12/2017, A5E03444486-AH Functions 5.12 Accelerating startup 5.12.4 Optimize the port settings Optimizing port settings on the IO device and IO controller The transfer medium and the duplex option are checked during startup of the IO device in the case of copper cabling. These checks require time, but with specific presets of these options you can save the time the check requires. Make certain that the settings made correspond to the actual conditions (using the correct cables). Optimizing port settings for accelerated startup To optimize port settings for accelerated startup, follow these steps: 1. Select the ports of the IO controller or the partner port of the corresponding IO device. 2. Navigate to "Port options > Connection" in the Inspector window. Select the setting "TP 100 Mbps full duplex" under "Transmission rate/duplex" 3. Clear the "Enable autonegotiation" check box. Figure 5-98 Optimizing port settings for accelerated startup in STEP 7 These settings are automatically applied during topology configuration for the partner port. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 255 Functions 5.12 Accelerating startup 5.12.5 Optimize the cabling of the ports Requirements You have made the following settings for the port in question to reduce the startup time of the IO device: ● Fixed transmission rate ● Autonegotiation deactivated The time for negotiating the transmission rate during startup is saved. If you have disabled autonegotiation, you must observe the cabling rules. Properties of ports PROFINET devices have the following two types of ports: Type of port Switch port with crossed pin assignment PROFINET devices For IO devices: Port 2 For S7-CPUs with two ports: Ports 1 and 2 Terminal device port with normal pin assignment For IO devices: Port 1 For S7-CPUs with one port: Port 1 Crossed pin assignment means that the pin assignment for the ports for sending and receiving between the respective PROFINET devices is inverted internally. Validity of the cabling rules The cabling rules described in the following paragraph apply exclusively for the situation in which you have specified a fixed port setting in STEP 7. Rules for cabling You can connect several IO devices in series using patch cables. To do this, connect port 2 of the IO device (distributed I/O) with port 1 of the next IO device. The following graphic provides an example with two IO devices. Figure 5-99 Optimized cabling for accelerated startup PROFINET with STEP 7 V15 256 Function Manual, 12/2017, A5E03444486-AH Functions 5.12 Accelerating startup 5.12.6 Measures in the user program Introduction You can make certain changes in the user program to accelerate the startup for IO devices of docking systems that alternate during operation. Making the required changes to the user program To accelerate the startup by making changes to the user program, follow these steps: 1. Call the "D_ACT_DP" instruction to activate and deactivate the IO device at the start of the OB 1 cycle. If the IO device is replaced, the device that is no longer required must be deactivated and the new device must be activated. 2. If you control the "Power ON" command of the IO devices via the application, then start the activation of the IO devices via the corresponding call of the "D_ACT_DP" instruction as near to the same time as possible. The IO device has to be physically connected for this. 3. You access the IO device using direct access commands after the "D_ACT_DP" instruction has provided the feedback "IO device activated". PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 257 Glossary API API (Application Process Identifier) is a parameter, the value of which specifies the IO data processing process (application). The PROFINET standard IEC 61158 assigns profiles to specific APIs (PROFIdrive, PROFIsave), which are defined by the PROFINET user organization. The standard API is 0. Application An application is a program that runs directly on the MS-DOS/Windows operating system. An application on the PG is STEP 7, for example. AR AR (Application Relation) is an addressing level for diagnostics data records. Asset An asset is a component of a machine or plant This can be either hardware or software/firmware. Automation system Programmable logic controller for the open-loop and closed-loop control of process chains of the process engineering industry and manufacturing technology. The automation system consists of different components and integrated system functions according to the automation task. Backplane bus The backplane bus is a serial data bus for module intercommunication and the distribution of the necessary power to the modules. Bus connectors interconnect the modules. Bus A bus is a transfer medium that interconnects several devices. Data transmission can be performed electrically or via optical fibers, either in series or in parallel. PROFINET with STEP 7 V15 258 Function Manual, 12/2017, A5E03444486-AH Glossary Communications Cycle and Reservation of Transmission Bandwidth PROFINET IO is a scalable real-time communication system based on the Layer 2 protocol for Fast Ethernet. With the RT transmission method, two real-time-support performance levels are available for time-critical process data and IRT for high-accuracy and also isochronous processes . Communications processor Communication processors are modules used for point-to-point and bus connections. Configuring Selecting and putting together individual components of an automation system or installing necessary software and adapting it for a specific application (for example, by configuring the modules). Consistent data Data which belongs together in terms of content and must not be separated is known as consistent data. For example, the values of analog modules must always be handled as a whole, that is, the value of an analog module must not be corrupted as a result of reading out at two different points in time. CP → Communications processor CPU Central Processing Unit - Central module of the S7 automation system with a control and arithmetic unit, memory, operating system and interface for programming device. DCP DCP (Discovery and Basic Configuration Protocol). Enables the assignment of device parameters (for example, the IP address) using manufacturer-specific configuration/programming tools. Default router The default router is used when data has to be forwarded via TCP/IP to a partner located outside the local network. Determinism Determinism means that a system responds in a predictable (deterministic) manner. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 259 Glossary Device In the PROFINET environment, "device" is the generic term for: ● Automation systems (for example, PLC, PC) ● Distributed I/O systems ● Field devices (for example, PLC, PC, hydraulic devices, pneumatic devices) ● Active network components (for example, switches, routers) ● Gateways to PROFIBUS, AS interface or other fieldbus systems Device name (PROFINET device name) In the PROFINET IO environment, the device name is a unique identifier for the PROFINET IO interface of a device. Diagnostics → System diagnostics Diagnostics buffer The diagnostics buffer represents a backup memory in the CPU, used to store diagnostics events in their order of occurrence. Diagnostics error interrupt Modules capable of diagnostics operations report detected system errors to the CPU by means of diagnostics interrupts. → See also CPU DP master A master which behaves in accordance with EN 50170, Part 3, is known as a DP master. → See also Master DP slave A slave operated on PROFIBUS with PROFIBUS DP protocol and in accordance with EN 50170, Part 3 is referred to as DP slave. → See also Slave DPV1 The designation DPV1 refers to the functional extension of acyclic services (to include new interrupts, for example) provided by the DP protocol. The DPV1 functionality is integrated in IEC 61158/EN 50170, Volume 2, PROFIBUS. PROFINET with STEP 7 V15 260 Function Manual, 12/2017, A5E03444486-AH Glossary Duplex Half duplex: One channel is available for alternating exchange of information. Full duplex: Two channels are available for simultaneous exchange of information in both directions. Ethernet Ethernet is an international standard technology for local area networks (LAN) based on frames. It defines types of cables and signaling for the physical layer and packet formats and protocols for media access control. GSD file As a Generic Station Description, this file contains all properties of a PROFINET device that are necessary for its configuration in XML format. I-device The "I-device" (intelligent IO device) functionality of a CPU facilitates data exchange with an IO controller, for example, as intelligent preprocessing unit of sub-processes. In its role as an IO device, the I-device is accordingly integrated into a "higher-level" IO controller. Industrial Ethernet Industrial Ethernet is a guideline for installing an Ethernet in an industrial environment. The biggest difference from standard Ethernet is the mechanical current carrying capacity and noise immunity of the individual components. Interrupt An interrupt is an event that causes the operating system of an S7-CPU to automatically call an assigned organization block (interrupt OB) in which the user can program the desired reaction. Interrupt, diagnostics → Diagnostics error interrupt PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 261 Glossary IP address To allow a PROFINET device to be addressed as a device on Industrial Ethernet, this device also requires an IP address that is unique within the network. Example: An IPv4 address consists of 4 decimal numbers with the value range 0 to 255. The decimal numbers are separated by periods. The IP address is made up of the following components: ● Address of the network ● Address of the device (generally called the host or network node). IRT IRT is a synchronized communication protocol for cyclic exchange of IRT data between PROFINET devices. A reserved bandwidth is available in the send cycle for IRT data. The reserved bandwidth ensures that the IRT data can be transferred at reserved synchronized intervals, without being influenced also by higher other network loads (such as TCP/IP communication, or additional real-time communication). LAN Local Area Network - a local network to which multiple computers within a company are connected. The LAN therefore has a limited geographical span and is only available to the company or institution. Line depth Designates the number of external switches or integrated switches interconnected in series. MAC address Worldwide unique device identification for all Ethernet devices. It is assigned by the manufacturer and has a 3-byte vendor ID and 3-byte device ID as a consecutive number. Every PROFINET device is assigned a worldwide unique device identifier at the factory. This 6-byte long device identifier is the MAC address. Maintenance Required / Maintenance Demanded A "Maintenance required" system message can be defined for different wear parameters and an inspection of a component can be recommended, for example, when a certain number of operating hours has elapsed. The "Maintenance demanded" alarm is sent when the part involved needs to be replaced within a foreseeable period. (Example printer: The maintenance demanded alarm is sent when the ink/printer cartridges have to be replaced immediately.) PROFINET with STEP 7 V15 262 Function Manual, 12/2017, A5E03444486-AH Glossary Master Higher-level, active participant in the communication/on a PROFIBUS subnet. It has rights to access the bus (token), sends data and requests it. Media redundancy The so-called Media Redundancy Protocol (MRP) enables the configuration of redundant networks. Redundant transmission links (ring topology) ensure that an alternating communication path is made available if a transmission link fails. The PROFINET devices that are a part of this redundant network form an MRP domain. Micro Memory Card (MMC) Micro Memory Cards are memory media for CPUs and CPs. Their only difference to the SIMATIC memory card is the smaller size. S7-1500 and ET 200SP-CPUs use SIMATIC memory cards. MPI The multipoint interface (Multi Point Interface,MPI) represents the programming device interface of SIMATIC S7. It enables multiple devices (programming devices, text-based displays, OPs) to be operated simultaneously by one or more CPUs. Each device is identified by its unique (MPI) address. MRPD MRPD (Media Redundancy with Planned Duplication of Frames) based on IRT and MRP. To realize media redundancy with short update times, the PROFINET devices participating in the ring send their data in both directions. The devices receive this data at both ring ports so that there is no reconfiguration time. Network A network consists of one or more interconnected subnets with any number of devices. Several networks can exist alongside each other. OB → Organization block OPC OPC (OLE for Process Control) refers to a standard interface for communication in automation technology. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 263 Glossary Operating mode The SIMATIC S7 automation systems know the following operating states: STOP, STARTUP, RUN. Organization block Organization blocks (OBs) form the interface between the CPU operating system and the user program. The order in which the user program is executed is defined in the organization blocks. Parameter 1. Tag of a STEP 7 code block: 2. Tag used to set one or several characteristics of a module In delivery state, every module has practical basic settings, which can be modified by configuration in STEP 7. There are static and dynamic parameters PG → Programming device PLC → Programmable logic controller Prioritized startup Prioritized startup denotes the PROFINET functionality for accelerating the startup of IO devices operated on a PROFINET IO system with RT and IRT communication. It reduces the time that the correspondingly configured IO devices require in order to return to cyclic user data exchange in the following cases: ● After the power supply has returned ● After a station has returned ● After activation of IO devices Process image The process image is part of CPU system memory. At the start of cyclic program execution, the signal states of the input modules are transferred to the process image of the inputs. At the end of cyclic program execution, the process image of the outputs is transferred to the output modules as signal state. → See also System memory PROFINET with STEP 7 V15 264 Function Manual, 12/2017, A5E03444486-AH Glossary PROFIBUS Process Field Bus - European Fieldbus standard. PROFIBUS device A PROFIBUS device has at least one PROFIBUS interface with an electrical (RS485) or optical (polymer optical fiber, POF) interface. PROFIBUS DP A PROFIBUS with DP protocol that complies with EN 50170. DP stands for distributed I/O (fast, real-time capable, cyclic data exchange). From the perspective of the user program, the distributed I/Os are addressed in exactly the same way as the centralized I/Os. PROFIBUS Users Organization Technical committee dedicated to the definition and development of the PROFIBUS and PROFINETstandard. Additional information can be found on the Internet (Page ). PROFIenergy Function for energy saving in the process, for example, during pause times by briefly switching off the entire system via standardized PROFIenergy commands. PROFINET Open component-based industrial communication system based on Ethernet for distributed automation systems. Communication technology promoted by the PROFIBUS Users Organization. PROFINET device A PROFINET device always has a PROFINET interface (electrical, optical, wireless). A lot of devices also have a PROFIBUS DP interface to connect PROFIBUS devices. PROFINET IO Communication concept for the realization of modular, distributed applications within the scope of PROFINET. PROFINET IO is based on switched Ethernet with full-duplex operation and a bandwidth of 100 Mbps. PROFINET IO Controller Device used to address the connected IO devices. This means that the IO controller exchanges input and output signals with assigned field devices. The IO controller is often the controller on which the automation program runs. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 265 Glossary PROFINET IO Device A distributed field device that is assigned to one of the IO controllers (e.g. remote IO, valve terminals, frequency converters, switches) PROFINET IO System PROFINET IO controller with assigned PROFINET IO devices. Programmable logic controller Programmable logic controllers (PLCs) are electronic controllers whose function is stored as a program in the control unit. The structure and wiring of the device does not therefore depend on the controller's function. A programmable logic controller is structured like a computer. It consists of a CPU with memory, input/output modules and an internal bus system. The IOs and the programming language are oriented to the requirements of the control technology. Programming device Programming devices are essentially compact and portable PCs which are suitable for industrial applications. They are identified by a special hardware and software configuration for programmable logic controllers. Proxy The PROFINET device with proxy functionality is the substitute for a PROFIBUS device on Ethernet. The proxy functionality allows a PROFIBUS device to communicate not only with its master but also with all devices on PROFINET. With PROFINET, existing PROFIBUS systems can be integrated into the PROFINET communication with the aid of an IE/PB link, for example. The IE/PB Link PN IO then handles communication via PROFINET on behalf of the PROFIBUS components. In this way, you can link both DPV0 and DPV1 slaves to PROFINET. Real-time Real-time means that a system processes external events within a defined time. Real-time communication Group error for RT and IRT. PROFINET uses its own real-time channel (RT) rather than TCP/IP for communication of time-critical IO user data. PROFINET with STEP 7 V15 266 Function Manual, 12/2017, A5E03444486-AH Glossary Router A router interconnects two subnets. A router works in a similar way to a switch. With a router, however, you can also specify which communication devices may communicate via the router and which may not. The communication devices on various sides of a router can only communicate with one another if you have explicitly enabled communication between these devices via the router. Real-time data cannot be exchanged beyond subnet boundaries. RT PROFINET IO with Real Time communication (RT) is the optimal transmission method for time-critical applications in factory automation. PROFINET IO frames are prioritized over standard frames in accordance with IEEE802.1Q. This ensures the required determinism in the automation technology. Security Generic term for all the measures taken to protect against ● Loss of confidentiality due to unauthorized access to data ● Loss of integrity due to manipulation of data ● Loss of availability due to the destruction of data Send clock Period between two consecutive intervals for IRT or RT communication. The send clock is the shortest possible transmit interval for exchanging data. SIMATIC The term denotes Siemens AG products and systems for industrial automation. SIMATIC NET Siemens Industrial Communication division for Networks and Network Components. SIMATIC PC Station A "PC station" is a PC with communication modules and software components within a SIMATIC automation solution. SIMATIC Memory Card (SMC) → Micro Memory Card (MMC) PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 267 Glossary Slave A slave can only exchange data after being requested to do so by the master. → See also DP slave SNMP The network management protocol SNMP (Simple Network Management Protocol) uses the wireless UDP transport protocol. It consists of two network components, similar to the client/server model. The SNMP manager monitors the network nodes and the SNMP agents collect the various network-specific information in the individual network nodes and stores it in a structured form in the MIB (Management Information Base). This information allows a network management system to run detailed network diagnostics. STEP 7 STEP 7 is an engineering system and contains programming software for the creation of user programs for SIMATIC S7 controllers. Subnet All the devices interconnected by switches are nodes of the same network or subnet. All the devices in a subnet can communicate directly with each other. All devices in the same subnet have the same subnet mask. A subnet is physically restricted by a router. Subnet mask The bits set in the subnet mask decide the part of the IP address that contains the address of the network. In general, the following applies: ● The network address is obtained from the AND operation of the IP address and subnet mask. ● The device address is obtained from the AND NOT operation of the IP address and subnet mask. Switch Network components used to connect several terminal devices or network segments in a local network (LAN). PROFINET with STEP 7 V15 268 Function Manual, 12/2017, A5E03444486-AH Glossary Sync domain All PROFINET devices to be synchronized with IRT via PROFINET IO must belong to a sync domain. The sync domain consists of exactly one sync master and at least one sync slave. An IO controller or switch generally handles the role of the sync master. Non-synchronized PROFINET devices are not part of a sync domain. System diagnostics System diagnostics refers to the detection, evaluation, and signaling of errors that occur within the automation system, for example, programming errors or module failures. System errors can be indicated by LEDs or in STEP 7. TCP/IP The Ethernet itself is only a transport system for data - similar to a highway, which is a transport system for people and goods. The actual data transport is performed by so-called protocols - similar to cars and trucks, which transport people and goods on the highway. The two basic protocols TCP (Transmission Control Protocol) and IP (Internet Protocol) TCP/IP for short - perform the following tasks: 1. The data is broken down into packets at the sender. 2. The packets are transported over the Ethernet to the correct recipient. 3. At the recipient, the packets are reassembled in the correct order. 4. Corrupt packets continue to be sent until they are received correctly. Most higher-level protocols use TCP/IP to perform their duties. Hyper Text Transfer Protocol (HTTP), for example transfers documents written in Hyper Text Markup Language (HTML) in the World Wide Web (WWW). This technique is what enables you to view web pages in your Internet browser in the first place. Topology Structure of a network. Common structures include: ● Linear bus topology ● Ring topology ● Star topology ● Tree topology Topology configuration All the interconnected ports of the PROFINET devices in the STEP 7 project and their relationships to each other. PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 269 Glossary Twisted-pair Fast Ethernet via twisted-pair cables is based on the IEEE 802.3u standard (100 Base-TX). The transmission medium is a shielded 2x2 twisted-pair cable with an impedance of 100 Ω (AWG 22). The transmission characteristics of this cable must meet the requirements of category 5. The maximum length of the connection between the terminal and the network component must not exceed 100 m. The connectors are designed according to the 100Base-TX standard with the RJ45 connector system. Update time An IO device / IO controller in the PROFINET IO system is supplied cyclically with new data from the IO controller / IO device within this time interval. The update time can be configured separately for each IO device and determines the interval at which data is sent from the IO controller to the IO device (outputs) as well as from the IO device to the IO controller (inputs). User program In SIMATIC, we distinguish between the CPU operating system and user programs. The user program contains all instructions, declarations and data by which a plant or process can be controlled. The user program is assigned to a programmable module (for example, CPU, CM) and can be structured in smaller units. WAN A network that extends beyond LAN boundaries and enables, for example, intercontinental network communication. Legal rights do not belong to the user but to the provider of the communication network. XML XML (Extensible Markup Language) is a flexible, easy to understand and easy to learn data description language. Information is exchanged using readable XML documents. These include continuous text supplemented by structure information. PROFINET with STEP 7 V15 270 Function Manual, 12/2017, A5E03444486-AH Index CPU display A Diagnostics, 97 Accelerating startup, 252, 252 IP address, 52 Adapting the user program, 257 Optimize the port settings, 255 Optimizing cabling, 256 Advanced offline/online comparison Automatic device assignment, 76 Cut through, 175 D D_ACT_DP, 247 Data access, 23 Alarm texts, 98 Data exchange between IO systems, 123 Alternating IO devices during operation, 246 Data security Alternating partner ports during operation, 246 Basics, 38 Asset management, 83 Example, 41 Assigning parameters, 43 SCALANCE, 40 Assignment IO device - controller, 45 Security, 39 Default router, 50 B Device name, 48, 216 Bandwidth, 135 Automatically assign, 47 Changing, 54 C Exchanging without removable storage medium, 52 Cables, 33 Permitting changes directly on the device, 60 Calling status from IO device, 78 Structured, 48 Channel, 28 Device number, 49 Communication, 22 Device replacement Compare offline/online Automatic device assignment, 74 Assign device name, 212 Configuring, 212 Configuration control, 217 Failure and replacement of an IO device, 211 Configuration control for IO systems, 217, 227, 241 Neighborhood detection, 211 Configuring, 43 Without exchangeable medium/programming device, 210 Configuring docking system, 248 Configuring hardware and assigning parameters for hardware, 43 Device replacement without exchangeable medium/programming device, 52, 210 Devices & networks, 103 DHCP, 61 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 271 Index Diagnostics, 77 G Diagnostics status, 111 Gateway, 61 Evaluation of interrupts, 112 Go online, 103 I-device, 130 GSD file, 127 PROFINET ports, 105 STEP 7, 103 H User program, 111 Hardware and network editor via CPU display, 97 Assign device name, 47 via LEDs, 96 Assign IP address, 47 via Web server, 100 Topology view, 70 Diagnostics buffer, 98 Diagnostics data record, 109 Channel-specific, 109 Vendor-specific, 109 I I&M data, 81 downloading to PROFINET IO devices, 81 Diagnostics levels, 79 I/O communication, 46, 57 Diagnostics status, 111 Identification data, 81 Display Identification of the PROFINET device, 56 Diagnostics, 97 IP address, 52 DNS conventions, 48 I-device, 137 Configuring with GSD file, 127 I-device (intelligent IO device) Docking station, 246 Alarm response, 130 Docking unit, 246 Configuring, 125 Diagnostics, 130 E Functionality, 118 Evaluation of interrupts, 112 Lower-level PN IO system, 120 Exchangeable medium, 210 Properties, 119 Topology rules, 133 F IE/PB link, 115 Fast Ethernet, 30 Industrial Ethernet, 17, 30 Fiber-optic cable (FOC), 33 Industrial Wireless LAN, 35 Fieldbus integration, 113 Application examples, 36 Full-duplex mode, 31 Range, 37 Functionality I-device, 118 Instruction SYNC_PI, 207 PROFINET IO, 27 PROFINET with STEP 7 V15 272 Function Manual, 12/2017, A5E03444486-AH Index SYNC_PO, 207 Isochronous mode Configuring, 205 T_CONFIG, 61 Definition, 198 Interconnecting ports In the Inspector window, 73 Example, 199 In topology view, 72 IPO model CAFC = 1, 202 IO controller, 45 IPO model CAFC >1, 204 IO device Programming, 207 Time synchronization, 200 Activating and deactivating during change, 247 Assigning, 45 Isochronous mode interrupt OB OB61 to OB64, 201 Calling status, 78 Configuring alternating partners, 248 Isochronous real-time, (see IRT) IO system, 218, 222, 224, 227, 229, 230, 238, 238 Checking the assignment, 46 L Data exchange, 123 LEDs for diagnostics, 96 IP address, 49 Assigning for the first time, 52 Linking PROFINET and PROFIBUS, 115 LLDP, 108 assigning using an different way, 56 Changing, 55 M Permitting changes directly on the device, 60 Machine tailoring, (see Configuration control for IO systems) IPO model CAFC = 1 Isochronous mode, 202 IPO model CAFC > 1 Isochronous mode, 204 IRT Area of application, 174 Communication, 175 Communication cycle, 177 Configuring, 179 Definition, 175 Differences of RT, 178 Properties, 176 Rules, 136 Setup recommendations, 184 Synchronization, 176 Maintenance concept, 106 Maintenance data, 81 Maintenance demanded, 106 Maintenance required, 106 Media redundancy Configuring, 164 Functions in ring topology, 161 Media Redundancy Protocol (MRP), 162 MIB, 108 Module, 28 Module status, 98 Module-internal shared input (MSI), 154 Module-internal shared output (MSO), 154 MRP, 162 MRPD, 167 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 273 Index MSI/MSO, 154 PROFINET, 17 Multiple use IO system, 216, 218, 222, 224 Assigning a device name, 57 Multiple use IO systems, 217 Communication, 22 Device model, 28 N Devices, 19 Neighborhood detection, 211 Equipment designations, 20 Network limits, 32 Implementation, 18 Network view Interface, 19, 25 Objectives, 17 I/O communication, 57 Optimizing with IRT, 184 O Optimizing with RT, 183 OB 6x, 207 Send clock, 24 OB 82, 112 Topology rules with I-device, 133 Online & diagnostics network view, 103 Transmission media, 34 Online assignment (PROFINET device names), 57 Update time, 24 Option handling in the network Watchdog time, 24 see Configuration control for IO systems, 227 Optional IO device, 229 PROFINET device name, 216 PROFINET interface Properties, 25 Overwriting the PROFINET device name, 216 Topology overview, 26 P PROFINET IO, 18 Diagnostics levels, 79 Port Alternating partners, 246 Functionality, 27, 113 Diagnostics, 105 System, 45 Switchport, 256 Proxy functionality, 115 Terminal port, 256 PST, 61 Prefabricating PCF cables, 33 Prefabricating POF cables, 33 R Primary Setup Tool (PST), 61 Real-time class, 32 Prioritized startup, 247 Real-time communication, 173, 174 Configuring, 254 Definition, 252 Redundancy, 161 Redundancy clients, 161 PROFIBUS, 17 Redundancy domains, 162 PROFIBUS & PROFINET International, 19 Redundancy manager, 161 PROFIenergy, 137, 243 Redundancy manager, 161 PROFINET with STEP 7 V15 274 Function Manual, 12/2017, A5E03444486-AH Index Ring port, 161, 166 Switch, 31 Ring topology, 161 Integrated, 26 Router, 32, 50, 65 Selection guide, 32 Switched Ethernet, 31 RT Area of application, 173 Switchport, 256 Communication cycle, 177 Sync domain, 176 Definition, 174 SYNC_PI, 207 Differences of IRT, 178 SYNC_PO, 207 Rules, 136 System diagnostics, 77 S T Saving energy, 243 T_CONFIG, 61 SCALANCE, 32, 37, 40 TCP/IP in the communication cycle, 177 Security Terminal port, 256 Definition, 39 Ti, 200 Example of data security, 41 To, 200 Protective measures, 40 Tool changer, 246 Send clock, 24 Topology Set/actual topology, 100 Example, 69 SFC 126 "SYNC_PI, 201 Line, 68 SFC 127 "SYNC_PO", 201 Ring, 68, 161, 162 Shared device, 138, 154 Rules about the IO-system with I-device, 133 SNMP, 108 Set/actual, 100 MIB, 108 Star, 68 Network diagnostics, 108 Tree, 68 Standard machine project, 216, 217, 218, 222, 224, 229, 230, 238, 238 Startup of IO devices, 247, 251 Store and forward, 174 Submodule, 28, 154 Subnet, 46 Subnet mask, 50 Assigning for the first time, 52 Example, 50 Topology overview, 26 Topology view Adopt devices identified online, 76 Adopt port interconnections identified online, 75 Hardware and network editor, 70 Interconnecting ports, 72 Transfer area, 137 Transmission bandwidth, 31 Transmission media with PROFINET, 34 Twisted-pair, 33 PROFINET with STEP 7 V15 Function Manual, 12/2017, A5E03444486-AH 275 Index U Update time, 24, 37 V Value status, 154 W Watchdog time, 24 Wire break, 107 Wireless networks, 37 PROFINET with STEP 7 V15 276 Function Manual, 12/2017, A5E03444486-AH
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : DF FA E&C PRM Comments : Company : Siemens AG Create Date : 2017:12:06 09:55:53+01:00 Keywords : A5E03444486-AH;, 12/2017 Modify Date : 2017:12:06 10:02:20+01:00 Source Modified : D:20171206084757 Subject : Function Manual Company-long : Siemens AG Company-short : Siemens Document-class : Function Manual Document-class-mrl : Edition : 12/2017 Order-nr : A5E03444486-AH Print-year : 2013 - 2017 Product-group : PROFINET System : SIMATIC Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Metadata Date : 2017:12:06 10:02:20+01:00 Creator Tool : Acrobat PDFMaker 11 für Word Document ID : uuid:ef641093-f8b4-4df1-990a-30fff3ab7a53 Instance ID : uuid:701f50a2-a9e2-4794-8254-c42186b0fcdb Format : application/pdf Title : PROFINET with STEP 7 V15 Description : Function Manual Creator : DF FA E&C PRM Producer : Adobe PDF Library 11.0 Headline : Function Manual Page Mode : UseOutlines Page Count : 277EXIF Metadata provided by EXIF.tools