EMCEE Broadcast TTU100FA UHF LPTV User Manual TUA100F Mnl Cover Pg 1
EMCEE Broadcast Products UHF LPTV TUA100F Mnl Cover Pg 1
TUA100FA
FAX: (570) 443-9257 Phone: (570) 443-9575 P.O. Box 68, White Haven, PA 18661 TUA100FA 100W SOLID STATE UHF POWER AMPLIFIER MDS MMDS ITFS LPTV North America South America Europe Asia Australia Africa Since 1960 TUA100FA 100W SOLID STATE UHF POWER AMPLIFIER BROADCAST PRODUCTS 04/99 TABLE OF CONTENTS I. THE TUA100FA POWER AMPLIFIER 1.1 1.2 1.3 1.4 1.5 II. CIRCUIT DESCRIPTION 2.1 III. Introduction Specifications Installation Operation Warranty and Parts Ordering Power Amplifier Drawer MAINTENANCE 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Periodic Maintenance Schedule Recommended Test Equipment Troubleshooting Chart Alignment TTU100FA Transmitter Power Calibration TU100FA Translator Power Calibration Spare Modules and Components IV. DATA PAK V. SCHEMATIC DIAGRAMS SECTION I THE TUA100FA POWER AMPLIFIER 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 1.2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 1.3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 1.4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 1.4a 1.4b 1.5 TTU100FA Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 TU100FA Translator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 Warranty and Parts Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 SECTION I THE TUA100FA POWER AMPLIFIER 1.1 Introduction: The EMCEE model TUA100FA Power Amplifier is rated to provide 100 watts peak visual and 10 watts average aural power on any FCC specified UHF channel extending from 470 to 806MHz when driven by the EMCEE TTU20F Transmitter or TU20F Translator. This compact, single drawer unit is completely solid-state and requires only minimal RF alignment, making it easy to service and maintain. The TUA100FA was designed for the express purpose of broadcasting as authorized by the Federal Communications Commission under Part 74, Subpart G of the FCC Rules and Regulations. 1.2 Specifications: Output Power 100W peak visual 10W average aural Output Frequency Range 470-806MHz (FCC Ch. 14-69) Gain 12dB Channel Flatness ±0.5dB Input Impedance 50 ohms (N connector) Output Impedance 50 ohms (N connector) Spurious Products >50dB below peak sync Harmonics >60dB below peak sync Intermodulation Products (IM3) >52dB below peak sync Differential Gain 5% maximum Differential Phase 3E maximum Color Transmission Compatible with PAL, SECAM, and NTSC Power Requirements 115Vac ± 15%, 60Hz, 700W 230Vac ± 15%, 50Hz (OPTIONAL) Ambient Temperature !30EC to +50EC 161 1.3 Mechanical Dimensions Power Amplifier Drawer 5.25"H x 19"W x 27"D Weight 30 lb. Installation: 1. After unpacking the EMCEE Model TUA100FA Amplifier, a thorough inspection should be conducted to reveal any damage which may have occurred during shipment. If damage is found, immediately notify the shipping agency and advise EMCEE Broadcast Products or its field representative. 2. Place the TUA100FA in a clean, weatherproof environment with adequate ventilation. Insure that the amplifier’s ambient temperature does not exceed the !30EC and +50EC limits and check to see that nothing blocks the exhaust fan located on the rear of the unit. IMPORTANT Do not apply ac power to the amplifier at this time since its RF output must be properly loaded before being placed in operation. 3. Place the amplifier in its permanent location near a 120Vac, 50 or 60Hz, single-phase receptacle. Unless the customer has specifically requested 220Vac operation, the amplifier will operate only from a 120Vac source. The ac source should have a minimum power capacity of 700 watts. 4. Set all circuit breakers and switches, including the ac mains breaker, to the OFF position. Place an appropriate ac power line protector (surge suppressor) across the ac line that supplies the amplifier. 5. Connect the EMCEE supplied interconnect harness to the TTU20F Transmitter or TU20F Translator CONTROL jack (J4) and the TUA100FA Amplifier CONTROL jack (J3). In the case of a transmitter system, find the two video sense wires connected to the TTU/TU20F CONTROL jack (J4) end of the harness but broken out separately. If video sense output is provided by the modulator, connect the striped white/orange/black wire to the video sense terminal and the black wire to the GND terminal on the modulator’s rear panel. Otherwise, clip off any bare conductor at the end of each wire and tie them back separately. For a translator system, plug the 9-pin D connector into the Receiver CONTROL jack (J7). 6. Connect the EMCEE supplied RF cable (N connector to N connector) to the RF OUT jack (J2) on the rear panel of the TTU/TU20F and the INPUT jack (J1) on the TUA100FA Power Amplifier's rear panel. 7. Connect the transmitting antenna cable to the Power Amplifier's RF OUT connector (J2). 162 1.4 Operation: 1.4a TTU100FA Transmitter: Assuming the installation instructions of Section 1.3 have been completed and the transmitter is receiving baseband video and audio signals, proceed with the following steps to place the transmitter in operation. It is assumed that the TTU20F is being used as a driver. 1. Place the modulator (A1) power switch to ON and verify that it provides 87.5% video modulation. If necessary, adjust the modulator for 87.5% video modulation as described in its instruction manual. 2. On the TTU20F Driver (A2), turn the POWER ADJUST control fully counterclockwise, place the OPERATE/STANDBY switch to STANDBY, and place the OPERATE/ALIGN switch to OPERATE. Place the meter switch to FWD and the POWER circuit breaker to ON. Then verify the following responses of the driver. 3. 4. a. The fans of the driver should be operating and exhausting air out the rear of the drawer. b. The driver OPERATE, SYNTH LOCK and DRIVER AMP indicators should be illuminated green. c. The TEMP EXCITER, ON, FINAL BIAS, and VSWR OVLD indicators should be extinguished. Place the TUA100FA Amplifier (A3) POWER switch to ON and meter switch to FWD. Verify the following responses of the amplifier drawer. a. The fans of the amplifier should be exhausting out the rear of the drawer. b. The FINAL ON and AMPL 1 indicators should be illuminated green and the TEMP indicator should be extinguished. Place the driver OPERATE/STANDBY switch to OPERATE. Then verify the following responses of the driver. a. The OPERATE, SYNTH LOCK, and DRIVER AMP indicators should remain illuminated. b. The ON and FINAL BIAS indicators should be illuminated green while the VSWR OVLD and TEMP indicators remain extinguished. 5. Turn the POWER ADJUST control clockwise until a 100% indication appears on the TUA100FA % POWER meter. The % POWER meter on the TTU20F may indicate less than 100% since a full 20W is not needed to drive the 100W amplifier. 6. Place both meter switches to REFLD and verify that neither % POWER meter indicates more than 10% returned power. If either reflected power is more than 10%, shut down the transmitter. Check the VSWR of the transmitting antenna and its associated cable or check the cable connecting the TTU20F Transmitter to the amplifier drawer. 7. Place the meter switches to FWD for constant monitoring of the transmitter’s output power. 163 The transmitter is now in operation. Check its coverage area for clean, sharp television reception. If the reception or picture quality is unsatisfactory, examine the amount of power delivered to the transmitting antenna and, if necessary, examine the antenna orientation, antenna VSWR, and transmission line VSWR to insure maximum radiation in the proper direction. 1.4b TU100FA Translator: Assuming the installation instructions of Section 1.3 have been completed and the translator is receiving RF signals, proceed with the following steps to place the translator in operation. It is assumed that the TU20F is being used to drive the TUA100FA Power Amplifier. 1. Place the Receiver’s power switch to ON and its OPERATE/ALIGN switch to OPERATE. Verify the following responses. a. 2. 3. 4. 5. The CARRIER PRESENT indicator should be illuminated green, indicating that a VHF/UHF signal of correct frequency and sufficient amplitude is being received. On the TTU20F Driver (A2), turn the POWER ADJUST control fully counterclockwise, place the OPERATE/STANDBY switch to STANDBY, and place the OPERATE/ALIGN switch to OPERATE. Place the meter switch to FWD and the POWER circuit breaker to ON. Then verify the following responses of the transmitter. a. The fans of the driver should be operating and exhausting air out the rear of the drawer. b. The driver OPERATE, SYNTH LOCK and DRIVER AMP indicators should be illuminated green. c. The TEMP EXCITER, ON, FINAL BIAS, and VSWR OVLD indicators should be extinguished. Place the TUA100FA Power Amplifier (A3) power switch to ON and meter switch to FWD. Verify the following responses of the amplifier drawer. a. The fans of the amplifier should be exhausting out the rear of the drawer. b. The FINAL ON and AMPL 1 indicators should be illuminated green and the TEMP indicator should be extinguished. Place the driver OPERATE/STANDBY switch to OPERATE. Then verify the following responses of the driver. a. The OPERATE, SYNTH LOCK, and DRIVER AMP indicators should remain illuminated. b. The ON and FINAL BIAS indicators should be illuminated green while the VSWR OVLD and TEMP indicators remain extinguished. Turn the POWER ADJUST control clockwise until a 100% indication appears on the TUA100FA % POWER meter. The % POWER meter on the TTU20F may indicate less than 100% which is appropriate. 164 6. Place both meter switches to REFLD and verify that neither % POWER meter indicates more than 10% returned power. If either reflected power is more than 10%, shut down the transmitter. Check the VSWR of the transmitting antenna and its associated cable or the cable connecting the TU20F Translator to the TUA100FA Amplifier drawer.. 7. Place the meter switches to FWD for constant monitoring of the transmitter’s output power. The translator is now in operation. Check its coverage area for clean, sharp television reception. If the reception or picture quality is unsatisfactory, examine the amount of power delivered to the transmitting antenna and, if necessary, examine the antenna orientation, antenna VSWR, and transmission line VSWR to insure maximum radiation in the proper direction. 1.5 Warranty and Parts Ordering: Warranty – EMCEE warrants its equipment to be free from defects in material and workmanship for a period of one year after delivery to the customer. Equipment or components returned as defective (prepaid) will be, at our option, repaired or replaced at no charge as long as the equipment or component part in question has not been improperly used or damaged by external causes (e.g., water or lightning). Semiconductors are excepted from this warranty and shall be warranted for a period of not more than ninety (90) days from date of shipment. Equipment or component parts sold or used by EMCEE, but manufactured by others, shall carry the same warranty as extended to EMCEE by the original manufacturer. Equipment Returns – If the customer desires to return a unit, drawer, or module to EMCEE for repair, follow the procedure described below: 1. Contact EMCEE Customer Service Department by phone or FAX for a Return Authorization Number. 2. Provide Customer Service with the following information: Equipment model and serial numbers. Date of purchase. Unit input and output frequencies. Part number (PN) and Schematic Diagram designator if a module is being sent. Detailed information concerning the nature of the malfunction. The customer shall designate the mode of shipping desired (e.g., Air Freight, UPS, FED EX, etc.). EMCEE will not be responsible for damage to the material while in transit. Therefore, it is of utmost importance that the customer insure the returned item is properly packed. Parts Ordering – If the customer desires to purchase parts or modules, utilize the following procedure: 1. Contact EMCEE Customer Service by phone or FAX indicating the customer's purchase order number. If the purchase order number is provided by phone, written confirmation of the order is required. 165 2. Also provide: The equipment model and serial number. The unit input and output frequencies. The quantity, description, vendor, number, and designation of the modules needed as found in the Spare Modules Lists subsection of this manual. If a module is required, give the part number (PN) and Schematic Diagram designator (e.g., 20362238). Designate the mode of shipping desired (e.g., Air Freight, UPS, FED EX, etc.). Shipping and billing addresses. Spare and Replacement Modules and Components – The Spare Modules and Components section of this manual provides a listing of the modules and some discrete components contained within the amplifier. This list contains those modules or components considered to be essential benchstock items and should be available to the maintenance technician at all times. The Schematic or Interconnection Diagram is the governing document of this manual. Should there be a discrepancy between a modules or components list and a diagram, the diagram takes precedence. Such a discrepancy is possible since manufacturing changes cannot always be incorporated immediately into the instruction manual. Module Referencing – The transmitter consists of drawers containing modules and components. Each drawer is given a reference designator starting with A1. Components and modules located in a drawer are referred to by their respective designators, preceded by the designator of the drawer in which they reside. Hence, the designator A1PS2 refers to power supply PS2 in drawer A1. This standard applies for all modular levels, i.e., A1A6A3 represents module A3, located in module A6, located in drawer A1. Components mounted directly to the cabinet take only a component reference designator. In the circuit description, Section 2, the full reference designator is given only with the schematic or interconnection diagram. In the text, the modules are referred to by their module number only, unless a module is mentioned that is located in a different drawer. Module designators on interconnect diagrams do not take the drawer designators. For EMERGENCY technical assistance, EMCEE offers a toll free, 24-hour, 7-day-a-week customer service hot line: 1-800-233-6193. 166 SECTION II CIRCUIT DESCRIPTION 2.1 Power Amplifier Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 2.1a 2.1b 2.1c 2.1d 2.1e 2.1f 2.1g 100W UHF Amplifier Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UHF Notch Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metering Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metering Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metering Display Assy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indicator Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32V Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii 261 262 262 262 263 264 264 SECTION II CIRCUIT DESCRIPTIONS 2.1 Power Amplifier Drawer: Interconnection Diagram 30383170/Rev 53 ò A3 RF OUT (J2) 100W (+50dBm) peak visual 10W (+40dBm) average aural 12dB Minimum Drawer Gain (J1-J2) The Power Amplifier drawer (A3) amplifies the composite RF output signal from the TTU20F Transmitter or the TU20F Translator (A2) to obtain 100 watts peak visual output with 10 watts of average aural. The drawer consists of an RF amplifier chain, a power detection/metering circuitry and an indicator circuit. Some monitoring and control of this drawer is also performed by the TTU/TU20F Driver. The RF amplifier chain is made up of a single LDMOS 100W UHF Amplifier module (A1), a 4.5MHz UHF Notch Filter (FL1) and a UHF Metering Coupler (DC1). The power detection/metering circuitry includes a Metering Detector (A2), Metering Switch (PC2), Metering Display Assembly (PC1) and an Indicator Circuit (PC3). The amplifier drawer has an internal 32V Power Supply (PS1) and slaves ±15V and +5V from the ±15V/+5V Power Supply (A2PS2) in the TTU/TU20F Upconverter/Amplifier Drawer. The drawer’s front panel provides a display of the amplifier’s % POWER using the Metering Display Assembly (PC1), which is a 30-segment LED bar array driven by information via the Metering Switch (PC2). Also on the front panel is the Indicator Circuit (PC3) which has three LEDs to indicate if the drawer is operational, the power amplifier has overheated, or if the amplifier module (A1) has experienced a fault. 2.1a 100W UHF Amplifier: Schematic Diagram 40383163/Rev 54 ò A3A1 Gain 13dB The TUA100FA contains a single 100 watt UHF power amplifier module (A1) having a nominal gain of 13dB in the UHF frequency band of 470 to 806MHz. The gain is derived from two parallel, class AB push-pull, LDMOS transistors (Q1, Q2) operating at 32Vdc. The RF signal enters the module through connector J1 and is split by a 90E hybrid, HY1. Each signal is then brought to separate coaxial baluns (Z1/Z2) both providing two signals that are 180E out of phase at the gates of their respective transistor pairs. The gate-source bias voltages for Q1 and Q2 are generated by monolithic voltage regulators U1 and U2 which are fed directly by 32V at pins 11 and 12. Potentiometers R8 and R12, in conjunction with resistors R7, R9, R11 and R13, control the outputs of U1and U2 and are typically set for a 10V at pin 10 of each regulator. Potentiometers R6 and R15 along with R4, R5, R16 and R17 provide individual fine adjustment for the gate-source biases of Q1 and Q2, a potential of approximately 4V. Input matching and signal coupling for each transistor are provided by capacitors C1-C6 with C25 for Q1, and C13-C18 261 with C36 for Q2. The outputs of each transistor pair are transformed into combined signals by coaxial baluns Z3 and Z4. These two signals are then combined again by 90E hybrid HY2 and delivered to the module output at J2. Output matching and coupling for each transistor pair are furnished by capacitors C8-C12, C62 for Q1, and C20-C24, C63 for Q2. Inductors L1 through L6 are employed as RF chokes with the remaining capacitors used for RF bypass. If a fault occurs in either transistor pair, the difference in power at the hybrid HY2 inputs will create an imbalance causing excessive power to appear at the HY2 ISOlation port. To monitor this fault, a power detection circuit, centered around diode CR1, transforms this excess power into a DC voltage which appears as a TTL high at terminal E11. On the Indicator Circuit (PC3) board this logic level high will change the front panel AMPL 1 status LED from green to red. 2.1b UHF Notch Filter: Schematic Diagram N/A ò A3FL1 Insertion Loss Notch Depth Notch Frequency 0.5dB maximum !12dB minimum Visual Carrier !4.5MHz Aural Carrier +4.5MHz This filter is a tunable two-section notch filter that removes the spurious products created through common amplification 4.5MHz below the visual carrier and above the aural carrier of the transmitted channel. Each notch has a minimum attenuation of 12dB, with the insertion loss of the passband at 0.5dB maximum. 2.1c Metering Coupler: Schematic Diagram 10199178/Rev 52 ò A3DC1 Insertion Loss (J1-J2) FWD Coupling (J1-J3) REFL Coupling (J1-J4) <0.5dB 30dB 30dB The Metering Coupler is a four port device designed to provide forward and reflected RF samples to the Metering Detector (A2) with minimal loss to the output signal. The RF signal from the Notch Filter is applied to the coupler’s input port (J1) and exits the coupler at J2 with a maximum of 0.5dB of loss. A !30dB sample of the signal’s forward power is provided at J3, and a !30dB sample of the reflected power is provided at J4. These two signals are connected through 6dB attenuators (AT3, AT4) to the metering detector which then provides DC signals, proportional to the amplifier’s output power, to the Control Board, AGC circuit, and Metering Switch. 262 2.1d Metering Detector: Schematic Diagram 30368024/Rev P ò A3A2 The Metering Detector contains three circuits for monitoring signal levels. Each of these circuits can take an RF signal at its input and provide a DC voltage at its output proportional to the input signal’s strength. Only two of the detector circuits are used in this application. From the Metering Coupler (DC1) a sample of the amplifier’s forward signal is supplied to the VISual port of the detector, and a sample of the reflected power is provided to the detector’s REFLected input. The front end or detector portion of each circuit is basically the same. Diodes CR2 and CR4, together with their surrounding components, convert the sampled on-channel RF signals to positive dc voltages proportional to the detected RF power. Detection of the sampled forward output is accomplished by CR2 in conjunction with R4 and C2 which form a time constant of 1 second. R4 is the dc load while C1 and C11 form the RF ground of the visual power detector. Detection of the sampled reflected signal is the same except for a faster time constant, as R22/C6 form a time constant of 1 millisecond. The positive dc voltages from the visual and reflected power detectors are processed by buffer amplifiers U1 and U2 which provide voltage gains of 1V/V and 2V/V, respectively. These buffer amplifiers also provide isolation between the % POWER meter and the detectors. The settings of potentiometers R9 and R27 determine the voltage level applied to the % POWER meter when the meter switch (A3PC2) is in its FWD or REFL position. Since common amplification of the visual and aural carriers is provided in this amplifier, the AURal detector circuit is not used. A dc voltage proportional to the amplifier's output power is applied to pin 5 of connector J4, designated VIS PWR REF. This power reference is fed back to the driver's (A2A1) AGC circuit contained in the IF/Upconverter. This voltage ultimately controls the attenuation of the composite IF carrier so that the amplifier's output is automatically maintained at its rated value. A dc voltage proportional to the amplifier's reflected output power is fed to pin 10 of comparator U2. This voltage is compared to a reference voltage at pin 9 whose magnitude is determined by potentiometer R30. With R30 properly set (see paragraph 3.5b), the voltage on pin 10 will be greater than the reference voltage whenever the amplifier's reflected power is more than 10% of its rated forward power. As a result, the output of the comparator saturates in the positive mode applying approximately +4Vdc to the VSWR OVLD line. This voltage instructs the Control Board (A2PC1) in the transmitter/driver that a VSWR overload condition has been detected. When the amplifier's reflected power is less than 10% of its rated forward power, the voltage on pin 10 of comparator U2 will be less than the reference voltage. As a result, the comparator saturates in the negative mode, diode CR1 is forward biased, and approximately !0.7Vdc is applied to pin 7 of connector J4. This voltage instructs the Control Board that no VSWR overload condition exists. 2.1e Metering Display Assy: Schematic Diagram 20362238/Rev 54 ò PC1 The Metering Display (PC1) consists of three 10-segment LED bar graphs (DS1, DS2, and DS3) and their drivers (U1, U2 and U3). Light Emitting Diodes DS1 and DS2 are green with DS3 colored red. The drivers are scaled so that at 100% forward output power all segments of DS1 and DS2 should be illuminated and at 50% only segments of DS1 should be illuminated. When the amplifier is operating at more than 100%, all segments of DS1 and DS2 will be lit with some or all portions of DS3 illuminated depending on the amount of output power over 100%. 263 2.1f Indicator Circuit: Schematic Diagram 20383174/Rev 53 ò A3PC3 The Indicator Circuit (PC3) is mounted to the front panel and contains three indicator LEDs. The FINAL ON indicator illuminates when the power switch is turned on and the 32V Power Supply (PS1) distributes power throughout the drawer. The TEMP LED illuminates when the thermostat, mounted on the heat sink of the power amplifier module, detects excessively high temperatures (175EF/80EC). When the 100W UHF Power Amplifier (A1) module is functioning properly, a logic "0/" is present on J2-A causing inverter U1 in the AMPL 1 status circuit to output a logic "1", placing approximately 5V across the green section of LED DS1. Buffer U2 essentially passes the logic "0/" bypassing the red section of the LED to ground, thus extinguishing it. If the amplifier module experiences a fault, a logic "1" is put on the AMPL 1 STATUS input J2-A, and the green LED section extinguishes while the red section illuminates. 32V is converted to +5V on this board by regulator U3 for use by inverters and buffers U1 and U2. 2.1g 32V Power Supply: Schematic Diagram N/A ò A3PS1 Output 32V @ 18.7A Max A +32V, 600 watt high performance, high efficiency power supply is used to power the 100W UHF Power Amplifier module. The supply is a single output, power factor corrected switching type. The 32V Power Supply is not field repairable. If defective, it should be returned to EMCEE for repair or replacement. 264 SECTION III MAINTENANCE 3.1 Periodic Maintenance Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361 3.2 Recommended Test Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361 3.3 Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362 3.4 Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364 3.4a 3.5 TTU100FA Transmitter Power Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364 3.5a 3.5b 3.6 Forward Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364 Reflected Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365 TU100FA Translator Power Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366 3.6a 3.6b 3.7 UHF Notch Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364 Forward Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366 Reflected Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367 Spare Modules and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S61 iii SECTION III MAINTENANCE 3.1 Periodic Maintenance Schedule: OPERATION 3.2 RECOMMENDATION ALIGNMENT Upon installation and at one-year intervals thereafter (see subsection 3.4). OUTPUT POWER CALIBRATION Same as above (see subsection 3.5). FANS Inspect as often as possible (at least monthly) and clean when necessary. No lubrication needed. Recommended Test Equipment: EQUIPMENT MANUFACTURER MODEL # Digital Multimeter HEWLETT PACKARD E2378A Oscilloscope TEKTRONIX 2232 VHF Sweep Generator WAVETEK 2001 50 Ohm RF Detector TELONIC BERKELEY 8553 30dB 150W Attenuator NARDA 769-30 Power Meter HEWLETT PACKARD 435B Step Attenuator KAY 1/432 Frequency Counter HEWLETT PACKARD 5386A Spectrum Analyzer HEWLETT PACKARD 8594E NTSC Video Generator TEKTRONIX TSG100 Television Modulator EMCEE EM1 Mixer MINI-CIRCUITS ZP-2 361 3.3 Troubleshooting Chart: The following chart is an aid to determining and correcting the causes of faults that may occur in this amplifier. Under normal operating conditions, the FINAL ON indicator should be illuminated green with the TEMP and AMPL 1 indicators unlit. If a problem develops, note the type of problem, the state of the indicator LEDs and % POWER meter and compare them to this chart. Refer to the Troubleshooting Chart in the TTU20F Transmitter or TU20F Translator manual as necessary. TROUBLESHOOTING CHART PROBLEM NO OUTPUT POWER INDICATORS ALL LEDs TEMP AMPL 1 FINAL ON % POWER DRIVER LOW OUTPUT POWER OR DISTORTED OUTPUT AMPL 1 CAUSE UNLIT YELLOW GREEN GREEN STBY RED NO fault indicated 362 SOLUTION No 32V or 5V available Check plug connections P9/P10 and 5V regulator (U3) output on Indicator Circuit board PC3. Faulty module or 32V Power Supply Shut off Xmtr/Xltr RF drive. While monitoring the 32V supply, remove the dc plug from each module and PC board in the drawer and the wire harness to the driver. If the 32V returns when a plug is removed, replace the associated module. If 32V does not return with all plugs removed, replace power supply. High ambient temperature inside drawer Ensure fans are operational and are not blocked. Faulty thermostat If amplifier A1 is cool, measure resistance across the thermostat. Replace thermostat if a short is present. Faulty amplifier module Replace amplifier module. Output power calibration is incorrect See Section 3.5 or 3.6. TROUBLESHOOTING CHART PROBLEM LOW OUTPUT POWER OR DISTORTED OUTPUT INDICATORS CAUSE NO fault indicated 363 SOLUTION Notch Filter misaligned See Section 3.4a. Xmtr/Xltr Driver misaligned Refer to the TTU/TU20F Instruction Manual. 3.4 Alignment: 3.4a UHF Notch Filter: 1. Place the Amplifier Drawer POWER ON switch to off. Disconnect the input cable from the Notch Filter and connect the filter’s input directly to the sweep generator's RF output. 2. Place the RF Detector directly on the RF OUTPUT connector (J2) of the transmitter. 3. Tune the sweep generator to the center frequency of the transmitter's output channel employing a 20MHz sweep width display on the oscilloscope. Display the 1MHz markers. 4. The filter adjustments are the two threaded rods located on the short side of the filter accessible through the left side panel toward the rear of the drawer. If they are not marked, slowly adjust one and observe which notch moves on the scope and set accordingly. Do not switch the positions of the individual notches. Set the lower notch to (Visual Carrier Frequency ! 4.5MHz). Set the upper notch to (Aural Carrier Frequency + 4.5MHz). The visual carrier frequency for the appropriate UHF channel can be found in Section 4, the Data Pak, or in Table 261. 5. 3.5 Remove the sweeper cable from the filter input and the RF Detector from the drawer output. Replace the Notch Filter input cable. TTU100FA Transmitter Power Calibration: To ensure proper transmission, the output power level and % Power Meter calibration should be checked once every year. With the meter switch in the FWD position, the % Power Meter has been factory calibrated for 100% with the transmitter providing 100 watts peak visual and 10 watts average aural. The following calibration procedure assumes that the visual carrier has 87.5% video modulation and 0% average picture level (APL). In the following steps, the power levels stated are those expected at the output of the transmitter. Therefore, when measuring these power levels as shown in Figure 366, be sure to take into account the 30dB factor provided by the attenuator. Power levels at 50% APL (stair steps) are included in brackets following the power levels at 0% APL (SYNC only). 3.5a Forward Power: 1. With the TTU20F in STANDBY and the TUA100FA Amplifier off (POWER ON circuit breaker down), set up the test equipment as shown in Figure 366. 364 3.5b 2. Verify that the modulator is operating and providing 87.5% video modulation. Place the 100 Watt Amplifier POWER switch to ON and make sure the Amplifier’s Meter Switch is in the FWD position. Place the TTU20F Transmitter STANDBY switch to OPERATE. 3. To set the output power, adjust the TTU20F POWER ADJUST for an external power meter reading of 69.5W [44W]. Note that 100W peak visual at 0% [50%] APL and 87.5% modulation plus 10W average aural equals 69.5W [44W] average power. 4. To check or adjust the visual to aural carrier ratio, replace the power meter in Figure 366 with a spectrum analyzer. Adjust the aural carrier level on the modulator for the desired ratio. Remove the spectrum analyzer and return the power meter to the Transmitter’s output and reset the output power for an external power meter reading of 69.5W [44W]. 5. With the external power meter showing the correct power, place the meter switch to FWD and check the TUA100FA front panel % Power Meter for a 100% indication. If this reading is not obtained, adjust potentiometer R9 of the Metering Detector (A3) for a 100% indication. The Metering Detector is mounted on the right-hand side wall near the front of the amplifier drawer and is accessible through the holes in the side wall. The % Power Meter on the TTU20F Transmitter/Driver will indicate less than 100% which is an appropriate reading. Reflected Power (OPTIONAL): 6. On the right side wall of the TUA100FA Power Amplifier drawer, adjust potentiometer R30 of the Metering Detector fully clockwise to disable the VSWR overload detection circuit. Place the amplifier drawer meter switch to REFL. 7. Place the Transmitter/Driver OPERATE/STANDBY switch to STANDBY and the OPERATE/ ALIGN switch to ALIGN. Remove and reverse the forward power (J3) and reflected power (J4) coupling port cables on the Metering Coupler (DC1). J1 and J3 of the Metering Detector (A3) should now be connected to J4 and J3 of the Metering Coupler (DC1), respectively. This simulates an open circuit at the amplifier's RF OUTput (J2) delivering maximum returned power to the REFL port of the Metering Detector. Insert a step attenuator between the modulator's IF OUTPUT and the transmitter's IF INPUT and set the step attenuator for 10dB attenuation. 8. Place the Transmitter/Driver OPERATE/STANDBY switch to OPERATE. Remove the attenuation from the step attenuator for an external power meter reading of 69.5W [44W]. Check the amplifier drawer's front panel REFL meter for a 100% [70%] reading. If necessary, adjust potentiometer R27 of the amplifier Metering Detector for the proper reading. R7 is accessible through the right-hand side wall of the drawer. 9. Decrease the transmitter's power to 50% by increasing the step attenuator 3dB for an external power meter reading of 34.75W [22W]. This power level is used for setting the trip point of the VSWR overload detection circuit. Adjust R30 of the amplifier’s Metering Detector slowly counterclockwise until the front panel VSWR OVLD indicator illuminates red and the Transmitter/Driver is placed in standby. 365 3.6 10. Check the VSWR OVLD trip point by setting the step attenuator for an additional 1dB of attenuation. Press the momentary VSWR RESET switch to reset the transmitter and remove the additional 1dB of attenuation from the step attenuator. The VSWR OVLD circuit should again trip. If it does not, repeat this section beginning at step #6. 11. Place the OPERATE/STANDBY switch to STANDBY. Return the Metering Coupler cables to their original ports, J3 and J4. Reinstall the top cover, slide the drawer back into the cabinet and secure it properly. Properly load the transmitter and place the Driver OPERATE/ ALIGN and OPERATE/STANDBY switches to OPERATE. TU100FA Translator Power Calibration: To ensure proper transmission, the output power level and % Power Meter calibration of the translator should be checked once every year. With the meter switch in the FWD position, the TUA100FA Amplifier % Power Meter has been factory calibrated for 100% with the translator providing 100 watts peak visual and 10 watts average aural. The following calibration procedure assumes that the composite signal received by the translator has the aural carrier 10dB down from the visual with the visual carrier having 87.5% video modulation and 0% average picture level (APL). In the following steps, the power levels stated are those expected at the output of the translator. Therefore, when measuring these power levels as shown in Figure 367, be sure to take into account the 30dB factor provided by the attenuator. Power levels at 50% APL (stair steps) are included in brackets following the power levels at 0% APL (SYNC only). This procedure also assumes the setup in Figure 367 is being used and that the output of the receiver drawer has been correctly calibrated. If the received broadcast channel frequency is in the VHF band (Ch.2-13), the mixer can be deleted from the test setup and a VHF agile modulator set on the correct channel may be connected directly to the RF INput (J1) of the Receiver drawer through an attenuator. 3.6a Forward Power: 1. With the TU20F Translator drawer in STANDBY and the TUA100FA Amplifier POWER ON circuit breaker switch open (down), set up the test equipment as shown in Figure 367. 2. Verify that the modulator is providing 87.5% video modulation with the aural 10dB below the visual and that the input signal is at the correct frequency (Receiver’s input channel) and at an amplitude between !40dBm to !47dBm. Place the TUA100FA 100 Watt Power Amplifier into operation and make sure the Meter Switch is displaying FWD power. Turn the TU20F Transmitter/Driver ON and place both the OPERATE/STANDBY and OPERATE/ALIGN switches to OPERATE. 3. To set the output power, adjust the Driver’s POWER ADJUST control for an external power meter reading of 69.5W [44W]. Note that 100W peak visual at 0% [50%] APL and 87.5% modulation plus 10W average aural equals 69.5W [44W]. 366 4. 3.6b With the external power meter reading the correct output power, place the meter switch to FWD and check the TUA100FA Amplifier front panel % Power Meter for a 100% indication. If this reading is not obtained, adjust potentiometer R9 of the Metering Detector (A3) for a 100% indication. The Metering Detector is mounted on the right-hand side wall near the front of the amplifier drawer and is accessible through the holes in the side wall. The % Power Meter on the TU20F Driver will read less than 100% which is an appropriate indication. Reflected Power (OPTIONAL): 5. On the right side wall of the 100W Power Amplifier drawer, adjust potentiometer R30 of the Metering Detector fully clockwise to disable the VSWR overload detection circuit and place the meter switch to REFL. 6. Place the Transmitter/Driver OPERATE/STANDBY switch to STANDBY and the OPERATE/ ALIGN switch to ALIGN. In the amplifier drawer remove and reverse the forward power (J3) and reflected power (J4) coupling port cables on the Metering Coupler (DC1). J1 and J3 of the Metering Detector (A3) should now be connected to J4 and J3 of the Metering Coupler (DC1), respectively. This simulates an open circuit at the amplifier’s RF OUTput (J2) delivering maximum returned power to the REFL port of the Metering Detector. Insert a step attenuator between the Receiver’s IF OUTPUT and the Transmitter’s IF INPUT and set the step attenuator for 10dB attenuation. 7. Place the Transmitter’s OPERATE/STANDBY switch to OPERATE. Remove attenuation from the stepper for an external power meter reading of 69.5W [44W]. Check the amplifier drawer's front panel meter for a 100% [70%] reading and, if necessary, adjust potentiometer R27 of the Amplifier’s Metering Detector for the proper reading. R27 is accessible through the right-hand side wall of the drawer. 8. Decrease the translator's power to 50% by increasing the step attenuator 3dB for an external power meter reading of 34.75W [22W]. This power level is used for setting the trip point of the VSWR overload detection circuit. Adjust R30 of the Amplifier’s Metering Detector slowly counterclockwise until the front panel VSWR OVLD indicator illuminates red and the Translator/Driver drops into standby. 9. Check the VSWR OVLD trip point by increasing the step attenuator an additional 1dB. Press the momentary VSWR RESET switch to reactivate the Translator and remove the additional 1dB of attenuation from the attenuator. The VSWR OVLD circuit should again trip. If it does not, repeat this section beginning at step #5. 10. Place the OPERATE/STANDBY switch to STANDBY. Return the Amplifier Metering Coupler cables to their original ports, J3 and J4. Reinstall the top cover, slide the drawer back into the cabinet and secure it properly. Properly load the Translator and place both the OPERATE/ALIGN and the OPERATE/STANDBY switches to OPERATE. 367 3.7 Spare Modules and Components: The following contains the description, vendor, part number, and designator of each module found in the TUA100FA Amplifier which EMCEE considers to be essential bench-stock items. These modules should be available to the technician at all times. TUA100FA SPARE MODULES LIST INTERCONNECTION DIAGRAM 30383170 (REV 53) DESCRIPTION VENDOR/PART # DESIGNATOR UHF Power Amplifier EMCEE/40383176-2 A1 32V Power Supply ASTEC/MP6-3T-00 PS1 Metering Detector EMCEE/60368050-1 A2 Metering Display EMCEE/60362240-1 PC1 Indicator Circuit EMCEE/20383186-1 PC3 Fans EMCEE/A2000-5 B1, B2 RF Cable EMCEE/A288-048-36 Interconnect Harness TTU100FA Transmitter EMCEE/60383052-1 OR Interconnect Harness TU100FA Translator EMCEE/60383092-1 Surge Suppressor GE/V150LA10A S61 E3, E4 SECTION V SCHEMATIC DIAGRAMS MODULE SCHEMATICS ARE LISTED IN ALPHANUMERICAL SEQUENCE
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 1999:12:22 09:07:56 Producer : Acrobat Distiller 3.01 for Windows Creator : Windows NT 4.0 Title : TUA100F Mnl Cover Pg 1 Modify Date : 1999:12:22 11:45:10 Page Count : 42EXIF Metadata provided by EXIF.tools