EMR HUHF800-40 Commercial Linear Amplifier User Manual HUHF800 40

EMR Corporation Commercial Linear Amplifier HUHF800 40

Service Manual

Download: EMR HUHF800-40 Commercial Linear Amplifier User Manual HUHF800 40
Mirror Download [FCC.gov]EMR HUHF800-40 Commercial Linear Amplifier User Manual HUHF800 40
Document ID143196
Application ID7WjwkYHJ49F3lLbkRT8Nsw==
Document DescriptionService Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize32.69kB (408685 bits)
Date Submitted2001-04-04 00:00:00
Date Available2001-04-04 00:00:00
Creation Date2001-02-27 15:15:10
Producing SoftwareAcrobat PDFWriter 4.0 for Windows NT
Document Lastmod2001-02-28 09:07:14
Document TitleHUHF800-40.PDF
Document CreatorCorelDRAW 9 - [HUHF800-40]
Document Author: jon

FCC Certification ID #
M7G-HUHF800-40
HUHF 800-40 SERIES
850-875 MHz AMPS
Table of Contents
PRODUCT DESCRIPTION............................
GENERAL SPECIFICATIONS.........................
CIRCUIT DESCRIPTIONS.............................
SCHEMATICS.............................................
PARTS LIST................................................
WARRANTY INFORMATION.........................
The HUHF 800-40 Series of EMR amplifiers are
intended for use in commercial communications
systems. Applications include cellular, SMR trunking
and data systems. They will cover the frequency
range extending from 850 MHz to 875 MHz.
For operator convenience, views of the
Amplifier are presented here..
FCC Certification
Label Placement
HUHF800-40
13.6
M7G-HUHF800-40
850-875
40 watts
FREQUENCY RANGE:
850 - 875 MHz
OPERATING MODE:
FM
USAGE:
Single Channel Systems
MODEL #:
HUHF 800-40
OUTPUT POWER:
40 WATTS
OPERATING
TEMPERATURE RANGE:
-20 to +60 Deg. C
OPERATING VOLTAGE:
+13.6 VDC / 8 amps
DUTY CYCLE:
HARMONIC
ATTENUATION:
OPTIONS:
FCC
Certification
LABEL
100%
Meets FCC
Certification
EMR Amplifiers are available
With several mechanical
mounting options and in
Various configurations.
(Specified at time of order.)
HUHF800-40
13.6
M7G-HUHF800-40
850-875
40 watts
The HUHF 800-40 Series power amplifier is a selfcontained rack mountable unit capable of up to 40
watts of class c output power, with built in cooling
circuitry and power reduction capability. The input
signal is amplified by a power module capable of
producing 14 watts. It is then split and amplified by
the output amplifiers and recombined with a
Wilkinson combiner. Finally, it is filtered by a seven
element low pass filter.
40 WATT SMR AMP
Bill of Materials Aug. 1, 2000
ITEM QUANTITY
REFERENCE
PART
___________________________________________________
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
C1,C8
C2, C3
C4
C5
C6,C12,C23
C7,C13
C9,C21
C10,C11
C14
C15
C16
C17
C18
C19,C20
C22
J1,J2
L1
L2,L3,L4
L5,L7,L8,L9
L6
Q1
Q2
R1,R2
Z1,Z2,Z3,Z4
4.3PF
47PF
.01UF
2.2UF
13PF
3PF
2.2PF
22PF
15PF
6.8PF
270PF
100PF
10PF
18PF
150PF
TYPE N
3.5T
12NH
4.5T
VK/4B
MRF847
MRF842
20
u-STRIP
EMR Corporation, hereinafter called EMR, warrants
that all equipment of its manufacture shall be free from defects
in design, materials and workmanship for a period of 12 months
from date of shipments unless otherwise covered by special
warranty. If any such product, entirely or in part, fails to produce
the performance set forth in the brochures, quotations or
literature provided by EMR, such product will be replaced or
repaired at EMR’s expense provided that the failure was not the
result of alteration, misuse, tampering, misapplication, shipping
damage or vandalism. If a product failure is found to be the
fault of EMR, costs of transportation to the EMR factory and
return will be born by EMR. Should EMR supply components not
of its own manufacture, but specified by a customer, the
warranty shall reflect the original manufactures warranty, only.
It is understood that this statement constitutes EMR’s entire
and only warranty, there being no other warrantees expressed or
implied in law or in fact, including implied warrantees of fitness.
In no event shall EMR be liable for damages either direct or
consequential, that may be occasioned by any defect in
materials, workmanship or product support.
For service on this amplifier, contact:
EMR Corporation
22402 N. 19th Avenue
Phoenix, Arizona 85021
Tel: 623/581/2875
800/796/2875
E-mail: info@emrcorp.com
http://www.emrcorp.com
FAX: 623/582/9499

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Creator                         : CorelDRAW 9 - [HUHF800-40]
Create Date                     : 2001:02:27 15:15:10
Title                           : HUHF800-40.PDF
Author                          : jon
Producer                        : Acrobat PDFWriter 4.0 for Windows NT
Modify Date                     : 2001:02:28 09:07:14-05:00
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M7G-HUHF800-40

Navigation menu