Edgecore Networks ECW7210L IEEE 802.11a/b/g/n/ac Enterprise Cloud Based Indoor Access Point User Manual Quick Start Guide

Edgecore Networks Corporation IEEE 802.11a/b/g/n/ac Enterprise Cloud Based Indoor Access Point Quick Start Guide

Contents

User Manual-1

Download: Edgecore Networks ECW7210L IEEE 802.11a/b/g/n/ac Enterprise Cloud Based Indoor Access Point User Manual Quick Start Guide
Mirror Download [FCC.gov]Edgecore Networks ECW7210L IEEE 802.11a/b/g/n/ac Enterprise Cloud Based Indoor Access Point User Manual Quick Start Guide
Document ID2221369
Application IDqEOuxl/+pQMPq4a5CE1KRA==
Document DescriptionUser Manual-1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize84.49kB (1056148 bits)
Date Submitted2014-03-20 00:00:00
Date Available2014-03-20 00:00:00
Creation Date2017-10-23 12:44:05
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-23 12:44:05
Document TitleQuick-Start-Guide.fm
Document CreatorFrameMaker 9.0
Document Author: angel_peng

Quick Star t Guide
IEEE 802.11a/b/g/n/ac Enterprise Cloud Based Indoor Access Point
ECW7210-L
Note: For detailed access point (AP) installation information, refer to the
Installation Guide, which is on the Documentation CD included with the AP.
Note: For Safety and Regulatory information, refer to the Safety and Regulatory
Information document included with the AP.
Installation Information
The AP includes its own built-in features for mounting the unit to a wall or
suspended ceiling T-rail.
Caution: The planning and installation of the AP requires professional personnel
that are trained in the installation of radio transmitting equipment. The user is
responsible for compliance with local regulations concerning items such as
antenna power, use of lightning arrestors, grounding, and radio mast or tower
construction. Therefore, it is recommended to consult a professional contractor
knowledgeable in local radio regulations prior to equipment installation.
Follow these steps to install the AP:
1. Unpack the AP Unpack the AP and check the package contents.
◆
◆
◆
◆
◆
◆
www.edge-core.com
ECW7210-L Enterprise Access Point
AC Power adapter
Console cable (RJ-45 to DB-9)
Quick Start Guide (this guide)
Regulatory and Safety Information
Screw Kit
– 1 –
150200000848A
E032014-AP-R01
Quick Start Guide
2. Mount the AP After planning your installation, mount the unit on a wall or suspended ceiling
T-rail.
.Mounting on a Wall
Set two screws in the wall 137.2 mm (5.2 in.) apart.
Slide the AP’s wall mounting slots down onto the screws so that the unit is secure.
.Mounting on a Ceiling T-rail
Position the AP’s ceiling-mount clip holders on either side of the T-rail.
Turn the AP until the two clips lock the AP to the T-rail.
– 2 –
Quick Start Guide
3. Connect Cables Connect network cable to the RJ-45 port for your network connection. The RJ-45
port connection can also provide PoE power to the unit.
Connect Category 5e or better cable to the RJ-45 port.
4. Connect Power If you do not power the unit using PoE, connect the AC power adapter to the AP
and to an AC power source.
Connect the power adapter to the power socket.
Connect the power adapter to a nearby AC power source.
– 3 –
Quick Start Guide
5. Verify AP Operation Verify basic AP operation by checking the system LEDs.
The Power LED should be on green and the LAN LED on or flashing green.
WiFi
Power
LAN
6. Connect to the To make initial configuration changes to the AP, connect a PC to the AP’s console
Console Port port using the included console cable.
– 4 –
Quick Start Guide
Console Port
Console Cable
From a PC running VT-100 terminal emulator software, use the following settings:
◆
◆
◆
◆
◆
◆
Baud rate — 115,200 bps
Character Size — 8 Characters
Parity — None
Stop bit — One
Data bits — 8
Flow control — none
Log in to the command-line interface (CLI) using default settings:
◆
◆
Login Name — admin
Password — null (there is no default password)
7. Connect to the Web The AP offers a user-friendly web-based management interface for the
User Interface configuration of all the unit’s features.
You can make initial configuration changes by connecting a PC directly to the AP’s
LAN port. The AP has a default management IP address of 192.168.1.10 and a
subnet mask of 255.255.255.0. You must set your PC IP address to be on the same
subnet as the AP (that is, the PC and AP addresses must both start 192.168.1.x).
Log in to the web interface using the default settings:
◆
Login Name — admin
◆
Password — tallacnetworks
– 5 –
Quick Start Guide
8. Security Slot The access point includes a Kensington security slot on the rear panel. You can
prevent unauthorized removal of the access point by wrapping the Kensington
security cable (not provided) around an unmovable object, inserting the lock into
the slot, and turning the key.
– 6 –
Quick Start Guide
Hardware Specifications
Item
Specification
Chassis Specifications
Size
W x D x H: 180 x 160 x 53 mm (7.08 x 6.29 x 2.08 inches)
Weight
638 g (1.40 lb)
Temperature
Operating: 0 °C to 40 °C (32 °F to 104 °F)
Storage: -20 °C to 70 °C (-4 °F to 158 °F)
Humidity
Operating: 5% to 95% (non-condensing)
Network Interfaces
Ports
Two RJ45 1000Base-T: One with PoE (PD)
2.4 GHz Radio
IEEE 802.11b/g/n
5 GHz Radio
IEEE 802.11a/n/ac
Radio Frequencies
2.4 GHz
2400 ~ 2483.5 MHz
5 GHz
B1: 5150 ~ 5250 MHz
B4: 5725 ~ 5850 MHz
Power Supply Specifications
PoE Input Power
48 VDC, 0.6 A
AC Power Adapter
AC Input: 100 ~ 240 VAC, 50 ~ 60 Hz
DC Output: 12 VDC, 2.5 A
Power Consumption
20 W maximum
Regulatory Compliances
Radio
FCC Part 15C 15.247/15.207 (2.4-2.4835GHz, 5.725-5.850GHz)
FCC Part 15E 15.407 (5.150GHz-5.250GHz)
Emissions
FCC Class B Part 15
Safety
UL 60950-1
– 7 –

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Author                          : angel_peng
Create Date                     : 2009:04:28 17:46:20Z
Modify Date                     : 2014:03:20 09:12:31+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : Quick-Start-Guide.fm
Creator                         : angel_peng
Creator Tool                    : FrameMaker 9.0
Metadata Date                   : 2014:03:20 09:12:31+08:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:e82265e4-e00a-40ff-8b36-388955a9645c
Instance ID                     : uuid:ea6fdfd5-deb9-435d-8682-285de0a4c917
Page Mode                       : UseNone
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YZKECW7210L

Navigation menu