Elettronika S r l TXUP5000 TXUP5000 5 kW Analog TV Transmitter User Manual APT120A AUTV 5000LD Rev0 Date221003 p65

Elettronika S.r.l. TXUP5000 5 kW Analog TV Transmitter APT120A AUTV 5000LD Rev0 Date221003 p65

Contents

User Manual Part 1

Download: Elettronika S r l TXUP5000 TXUP5000 5 kW Analog TV Transmitter User Manual APT120A AUTV 5000LD Rev0 Date221003 p65
Mirror Download [FCC.gov]Elettronika S r l TXUP5000 TXUP5000 5 kW Analog TV Transmitter User Manual APT120A AUTV 5000LD Rev0 Date221003 p65
Document ID686924
Application IDsg5khK0Ykr5mXyBh5L8E4w==
Document DescriptionUser Manual Part 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize168.17kB (2102158 bits)
Date Submitted2006-07-27 00:00:00
Date Available2007-01-31 00:00:00
Creation Date2006-03-08 10:57:03
Producing SoftwareAcrobat Distiller 3.0 for Windows
Document Lastmod2006-03-08 10:57:20
Document TitleAPT120A_AUTV_5000LD_Rev0_Date221003.p65
Document CreatorPageMaker 6.5
Document Author: Gianluca

AUTV/5000LD
LDMOS - UHF TV Solid State Amplifier
User’s manual
CODE: APT120A
TITLE: AUTV/5000LD
REV: 0
DATE: 22/10/03
Registration number: IT-17686
Registration number: IT-24436
SS 96 Km 113
70027 Palo del Colle (Ba) ITALY
Tel. +39 (0)80 626755
Fax +39 (0)80 629262
E-mail: elettronika@elettronika.it
Web siste: http://www.elettronika.it
WARNING
The apparatus described in this manual has been designed and manufactured with devices to safeguard the users. In any case it is recommended that during any operation of installation, maintenance,
miscellaneous interventions and calibrations requiring the apparatus to be switched on,
THE USER TAKES ALL THE
PRECAUTIONS AGAINST INCIDENTS
It is required to use the proper clothes and protection gloves in order to prevent damages from incidental contacts with high-voltage parts.
The manufacturer declines every responsibility in case the recommendations above are not followed.
IMPORTANT
The component lists attached to the relevant electrical diagrams indicate for each item the reference,
the description and the type normally used.
The Elettronika S.r.l. though reserves the right to use or supply as spare parts components with
equivalent characteristics but of a different type, assuring anyway the optimal work of the apparatus
in accordance with the specifications.
The enclosed monographs are solely owned by Elettronika S.r.l.
The use of anything enclosed in this technical manual without explicit authorization given by Elettronika
S.r.l. will be prosecuted by the law.
The data and technical characteristics of the apparatus described in this manual are not compelling for
the manufacturer.
The Elettronika S.r.l. reserves the right to make, without previous notice, modifications or updates in
order to improve the quality of the product.
The general conditions of supply and sale are described in the contracts.
The delivery time are in accordance with the products and quantities ordered.
Warranty
Summary of warranty
We, ELETTRONIKA S.r.l., SS096 Km 113 Z.I. PALO DEL COLLE (BA) ITALY, warrant to the ORIGINAL PURCHASER of a NEW product, for a
period of one (1) year from the date of purchase by the original purchaser (the “warranty period”) that the new ELETTRONIKA product is free of defects
in materials and workmanship and will meet or exceed all advertised specifications for such a product. This warranty does not extend to any subsequent
purchaser or user, and automatically terminates upon sale or other disposition of our product.
Items excluded from this ELETTRONIKA warranty
We are not responsible for product failure caused by misuse, accident, or neglect. This warranty does not extend to any product on which the serial
number has been defaced, altered, or removed. It does not cover damage to loads or any other products or accessories resulting from ELETTRONIKA
product failure. It does not cover defects or damage caused by use of unauthorized modificstions, accessories, parts, or service.
What we will do
We will remedy any defect, in material or workmanship (except as excluded), in our sole discretion, by repair, replacement, or refund. If a refund is
elected, then you must make the defective or malfunctioning component available to us free and clear of all liens or other encumbrances. The refund will
be equal to the actual purchase price, not including interest, insurance, closing costs, and other finance charges less a reasonable depreciation on the
product from the date of original purchase. Warranty work can only be performed at our authorized service centers or at our factory. Expenses in
remedying the defect will be borne by ELETTRONIKA, including one-way surface freight shipping costs within the United States. (Purchaser must bear
the expense of shipping the product between any foreign country and the port of entry in the United States and all taxes, duties, and other custom’s fee(s)
for such foreign shipments).
How to obtain warranty service
You must notify us of your need for warranty service not later than ninety (90) days after the expiration of the warranty period. We will give you an
authorization to return the product for service. All components must be shipped in a factory pack or equivalent which, if needed, may
Desclaimer of consequential and incidental damages
You are not entitled to recover from us any consequential or incidental damages resulting from any defect in our product. This includes any damage
to another product or products resulting from such a defect.
Warranty alterations
No person has the authority to enlarge, or modify this warranty. The warranty is not extended by the lenght of time for which you are deprived of
the use of the product. Repairs and replacement parts are provided under the terms of this warranty shall carry only the unexpired portion of this
warranty.
Design changes
We reserve the right to change the design of any product from time to time without notice and with no obligation to make corresponding changes in
products previously manufactured.
Legal remedies of purchaser
There is no warranty which extends beyond the terms hereof. This written warranty is given in lieu of any oral or implied warranties not contained
herein. We disclaim all implied warranties, including without limitation any warranties of merchantability or fitness for a particular purpose. No action
to enforce this warranty shall be commenced later than ninety (90) days after expiration of the warranty period.
Warranty for electronic tubes
The warranty applied for electronic tubes is the one given by the manufacturer of the tube. In the event that the product shows anomalies within the
deadline of the validity of the warranty given by the manufacturer of the product itself, the buyer will have to return it to the seller with the needed
documents and the written description of the defect. The seller will ship the broken tube to the manufacturer in order to effect the necessary technical
tests to find out the cause of the anomaly. Meanwhile the buyer of the tube who needs to use, and as such to replace immediately the product, will have
to buy a new one and provide to the relevant payment, further to the issuing by the seller of a regular commercial invoice. After the adequate tests made
by the manufacturer, should the result be positive, that is confirm the defect in manufacturing, the seller will issue a regular credit note in the name of
the buyer and return the amount paid. Should the result be negative, that is detect a negligence in the installation or use by the buyer, he will have no
right against the seller.
INTRODUCTION
The apparatus described in this manual is the latest of this series, offering high performances, remarkable reliability and a wide range of characteristics, it all at a low cost.
Its is easy to install and use. It only takes to follow the installation procedure as shown in this manual:
after having removed all from the package, you only have to follow step by step the description in the
various sections.
Before starting to use the apparatus, remember to:
read carefully the general safety information contained in this section;
follow the instructions for the installation and set up of the apparatus;
read all the remaining sections of this manual in order to know well the apparatus and learn
how to obtain the best of its characteristics.
CONTENTS OF THE MANUAL
The chapter composing this manual contain all the information concerning the use of the apparatus.
For more information refer to ELETTRONIKA S.r.l.
This manual is made up of different chapters, each made up of various sections. Each individual
chapter represents a single apparatus composing the whole station.
WARNING!
The currents and voltages in this equipment are dangerous!
Personnel must at all times observe safety regulation!
This manual is intended as a general guide for trained and qualified personnel who are aware of the
dangers inherent in handling potentially hazaedous electrical and electronic circuits.
It is not intended to contain a complete statement of all safety precautions which should be observed by
personnel in using this or other electronic equipment.
The installation, operation, maintenance and service of this equipment involves risks both to personnel
and equipment, and must be performed only by qualified personnel exercising due care.
Elettronika S.r.l. shall not be responsible for injury or damage resulting from improper procedures or
from the use of improperly trained or inexperienced personnel performing such tasks.
During installation and operation of this equipment, local building codes and fire protection standards
must be observed.
WARNING!
Always disconnect power before opening covers,
doors, enclosures, gates, panels or shields.
Always use grounding nsticks and short out high
voltage points before servicing. Never make
internal adjustments, perform maintenance or
service when alone or when fatigued.
Do not remove, short-circuit or tamper with interlock switches on access covers, doors, enclosures,
gates, panels or shields.
Keep away from live circuits, know your equipment and don’t take chances.
WARNING!
In case of emergency ensure that power has been disconnected.
Treatment of electrical shock
1) If victim is not responsive follow the A, B, C’s of basic life support.
PLACE VICTIM FLAT ON HIS BACK ON A HARD SURFACE
A - AIRWAY
B - BREATHING
If unconscious, open airway lift up neck, push
forehead back, clear out mouth if necessary,
observe for breathing.
If not breathing, begin artificial breathing. Tilt
head, pinch nostrils, make airttght seal, 4 quick
full breaths. Remember mouth to mouth resuscitation must be commenced as soon as possible.
C - CIRCULATION
Check carotid pulse. If pulse
absent, begin artificial circulation.
Approx. 80sec.: 1 rescuer, 15 compressions, 2 quick breaths.
Approx. 60sec.: 2 rescuers, 5 compressions, 1 breath.
NOTE: DO NOT INTERRUPT RHYTHM OF COMPRESSIONS WHEN
SECOND PERSON IS GIVING BREATH.
Call for medical assistance as soon as possible.
2) If victim is responsive:
- keep them warm;
- keep them as quiet as possible;
- loosen their clothing (a reclining position is recommended).
FIRST-AID
Personnel engaged in the installation, operation, maintenance or servicing of this equipment are urged
to become familiar with first-aid theory and practices. The following information is not intended to be
a complete first-aid procedure, it is brief and is only to be used as a reference. It is the duty of all
personnel using the equipment to be prepared to give adequate Emergency First Aid and thereby prevent avoidable loss of life.
TREATMENT OF ELECTRICAL BURNS
1) Extensive burned and broken skin.
- Cover area with clean sheet or cloth (cleansed available cloth article);
- do not break blisters, remove tissure, remove adhered particles of clothing, or apply any salve or
ointment;
- treat victim for shock as required;
- arrange transportation to a hospital as quickly as possible;
- if arms or legs are effected keep them elevated.
NOTE
If medical help will not be available within an hour and the victim is conscious and not vomiting, give
him a weak solution of salt and soda: 1 level teaspoonful of salt and 1/2 level teaspoonful of baking
soda to each quart of water (neither hot or cold).
Allow victim to sip slowly about 4 ounces (half a glass) over a period of 15 minutes.
Discontinue fluid if vomiting occurs (do not give alcohol).
2) Less severe burns - (1st & 2nd degree).
- Apply cool (not ice cold) compresses using the cleansed available cloth article;
- do not break blisters, remove tissue, remove adhered particles of clothing, or apply salve or ointment;
- apply clean dry dressing if necessary;
- treat victim for shock as required;
- arrange transportation to a hospital as qickly as possible;
- if arms or legs are affected keep them elevated.
LDMOS - UHF TV AMPLIFIER
AUTV/5000LD
User’s manual
AUTV/5000LD
LDMOS - UHF TV SOLID STATE AMPLIFIER
DESCRIPTION
The AUTV/5000LD belongs to the High Power UHF products family of Television Amplifiers fully in solid
state technology.
The AUTV/5000LD series represents the 5kW TV Amplifier operating in the IV/V Band for Common
amplification process (separate amplification available) of the Vision and Sound carriers. This Transmitters
family has been designed to offer to the customer high performances, high reliability and greater simplicity in
their operation and maintenance procedures.
The Vision and Sound signal processing is provided for all TV Standards and all types of Audio applications
(Mono & Dual sound - NICAM) together with colour systems such as PAL - NTSC - SECAM. Thanks to
the amplitude and phase pre-correction circuit, it is possible to cancel the distortions in the output stage, thus
cutting down the operating costs. The RF transposition in the driver is carried out by a synthesizer with various
possibilities of accuracy and stability as well as precision offset locked by internal or external frequency
reference.
The RF amplifier is made up by four RF modules installed in a power rack, the modules are dedicated for the
Vision and Sound carriers common amplification. The amplifiers employ solid state LDMOS technology in
order to obtain wide band, reliability, and high efficiency. Each RF module has a built-in switching-mode
power supply unit, self-protected against overcurrents and overvoltages, as well as overtemperature and
VSWR for RF parameters. The cooling system is fully contained into the transmitter. The control unit provides
full management of the transmitter without the presence of the operator, the system includes a central controller
and several peripheral units installed in each RF module and rack. Controller and peripherals are connected
by a RS485 full-duplex bus.
Power supply output voltages and currents, forward and reflected power of any single power amplifier are
monitorized by central control unit.
In that way there is a single interface point between user and all the transmitter. The operator interface is made
by a high resolution LCD graphic display and a simple keyboard, the menu is very friendly and easy to use.
The Control Unit can be fully controlled in REMOTE mode via link or via modem in RS232 or other interface.
The equipment design allows the soft degradation (RF power loss) for several transistors faults.
10
TECHNICAL CHARACTERISTICS
RF SECTION
Frequenchy range ............................................................................................................................................ 470 - 860MHz
Output power .......................................................................................................................................................... 5kW PEP
Vision / Sound power ratio ...................................................................................... 10/1 single sound - 20/1/0.2 dual sound
Out stage technology ............................................................................................................................. Solid State LDMOS
Vision / Sound amplification .................................................................................................................................... Common
Standards ................................................................................................................................................................ G, K, I, M
Sound transmission ..................................................................... FM single sound - Dual sound coding IRT - NICAM 728
Harmonics and suppression emission ..................................................................................... In compliance with CCIR rec.
Intermodulation products from vision and sound ................................................................................................... < = 50dB
Frequency stability ......................................................................................................................... 2,5ppm (option 0,05ppm)
VISION SECTION
Video input ............................................................................................................................................. BNC 75W connector
Nominal input level .............................................................................................................................................. 1Vpp ±6dB
Return loss ............................................................................................................................................................... > = 30dB
DC Restoration ........................................................................... Clamped to the blanking level without affecting the burst
White limiter ................................................................................. At 90% picture signal without affecting the chrominance
Transmission characteristics
Sideband spewctrum response .................................................................................................... According to the standard
Amplitude frequency response .................................................................................................... According to the standard
Group delay variation without receiver pre-correction and TV demodulator flat ................................................... < = ±35ns
Non linearity distortion (10 to 75% mod.) ................................................................................................................... < = 5%
Differential gain (10 to 75% mod.) ............................................................................................................................... < = 5%
Differential phase (10 to 75% mod.) .............................................................................................................................. < = 5°
Signal to random noise ratio (weighted 0.2 to 5MHz) .............................................................................................. > = 60dB
Blanking level variation ............................................................................................................................................... < = 2%
2T k factor ................................................................................................................................................................... < = 2%
SOUND SECTION
Nominal input level (±50kHz dev.) ..................................................................................................................... -10 to +8dBm
Input impedance ............................................................................................................................................ 600W balanced
Pre-emphasis .................................................................................................................................................................. 50ms
Transmission characteristics
Amplitude frequency response ............................................................................................................ 40 to 15000Hz ±0.5dB
Total harmonic distortion ......................................................................................................................................... < = 0.5%
FM Signal to noise ratio (referred to ±50kHz dev. f = 400Hz) ................................................................. > = 60dB (weighted)
AM Signal to nokise ratio .......................................................................................................... > = 50dB (referred to 100%)
AM Synchronous modulation ................................................................................................... < = 40dB (referred to 100%)
REMOTE CONTROL
Parallel interface ............................................................................................................................. On/Off, Alarms, Interlock
Serial interface ....................................................................................... RS232 or RS485 (Full monitoring and management)
11
GENERAL
Power supply voltage ................................................................................................... 3x380VAC, ±10% (other on request)
Frequency ........................................................................................................................................................ 50-60Hz, ±5%
Temperature operating range .................................................................................................................................. 0 to 45°C
Altitude ............................................................................... Up to 2.500 meters (> = 2.500m with additional cooling system)
Power consumption (cooling system included) ................................................................................. < = 12kVA (black level)
Power factor ................................................................................................................................................................ > = 0.9
Cooling .................................................................................................................................................................. Forced air
Dimensions ...................................................................................................................................................... Rack 19”-42U
12
AMPLIFIER CONTROL
RS232
MICROPRO CESSOR CONTROLL ED SYSTEM
CODE: APG012C
TITLE: AMPLIFIER CONTROL
REV: 1
DATE: 10/02/04
13
AMPLIFIER CONTROL
RS232
MICROPROCESSOR CONTROLLED SYSTEM
1.1 CONTROL SYSTEM OVERVIEW
The control system is made up by some “Slave” boards, which check locally the amplifier modules, and a
“Master” board to monitor the status of the Slave boards in each module and show on a graphic display all
the checked parameters.
The number of the Slaves changes depending on the output power of the amplifier. The communication
between Master and Slaves is made via RS485 standard. The Master board reads the overall parameters of
the equipment (Forward and Reflected power and Unbalancing), polls (interrogaes in sequence) the local
boards, shows on the display the values requested by the user, indicates alarm conditions, if any, and allows
to change some of the operating parameters of the apparatus. Besides it realizes a serial data interface to an
external system able to analyse the working parameters of the equipment, using the RS232 and RS485
communication protocols.
1.2 FUNCTIONS
At start-up, the display of Amplifier Control module shows an informational message concerning the equipment
and its firmware version.
- Main menu
The main menu has: a list of the amplifier modules, the measure of some parameters of the power in antenna,
a window with icons to show the alarm status (Alarm Status Window) and some general information, that is
date, time, temperature inside the module and, for FM equipment, transmission frequency.
The following picture is an exact representation of the main menu screen.
14
In the Amplifier List, next to each module, the following symbols can be found:
if the communication with the slave is correct and then
ON
if the amplifier module is ON
OFF
if the amplifier module is OFF
if the communication with the slave is interrupted
The UP and DOWN arrow keys allow to select one of the slave, the alarm list, or a menu allowing to change
some settings of the control module and the apparatus; the RET key is used to confirm the selection.
In the main and slave menu the Alarm Status Window (which position is indicated by an arrow in the picture
below) is shown: the gate symbol displays the status of the INTERLOCK, in case of alarm this icon blinks
and the buzzer ringgs.
The INTERLOCK signal is a control available to the user to manage an ON/OFF sensor.
When the relevant PIN is grounded, the Master board does not signal any alarm, as soon as the PIN is left
floating, an alarm is detected; the rotating screw symbol shows that the FANS work normally; in case of alarm
this icon blinks and the buzzer rings; the bell symbol appears in case of alarm detected by the control module
or the amplifier. It blinks if the alarm condition is terminated and the alarm itself can be displayed in the Alarm
List.
If one of the parameters of a Slave or any of the ones directly checked by the Master is alarmed, the general
15
alarm LED and the alarm icon blink until the Alarm List is checked to see the type of alarm occurred.
Besides, if an alarm for any of the powers of the signals in antenna occurs, the relevant measure in the
Antenna window of the display and the relevant LED on the front panel of the Master module blink until the
measure decreases below the threshold level, determined by the nominal power of the amplifier.
If the slave modules are working and an INTERLOCK or FANS alarm occurs, aside from the indication
explained above, the amplifiers are switched off. This happens immediately after an INTERLOCK alarm, or
about 7 seconds after a FANS alarm is detected.
In case the amplifiers are communicating but switched off, or they are not communicating and the INTERLOCK
alarm contact is open, a WARNING condition occurs: buzzer on and blinking ALARM LED on the front
panel; while if it is the FANS alarm contact to be open, the icon of the alarm appears in the box.
Further to any of these two alarms it is possible to choose whether to turn off the amplifiers or not. In fact,
there is a submenu of the Settings menu which allows to choose whether to turn off the amplifiers connected
to the control module as a consequence of an INTERLOCK and FAN alarm.
- Slave menu
By selecting one of the slaves, it is possible to see all the parameters of that amplifier module in two pages. The
first one shows voltages and currents Power Supply, the second one shows RF Powers: forward and reflected
power, temperature and, for some amplifiers, unbalancing and input power. The UP and DOWN keys allow
to scroll the local measures of all the slaves, page by page. The ESC key is used to go back to the main menu.
The following pictures show the menu screen of one amplifier.
Note that no numerical value is shown for amplifiers which are not communicating with the control module.
16
- Alarm List
By selecting the Alarm List, 26 pages listing the latest 130 alarms saved are shown. Each page shows 5
alarms, each contained in a box providing the following information: progressive number of the alarm, starting
with the most recent; number of the module in which the alarm occurred, following the “Blk.” Message (the
indication “AC” means that the alarm occurred in the Amplifier Control module); parameter in alarm, date and
time of the alarm. Next to the parameter showing the alarm type there may be a bell symbol. In case it is not
here, the alarm event has been communicated by an amplifier connected to the control module. These events
are different and on option of the Settings menu allows to choose whether they are displayed or not in the
alarm list.
The saved alarm can be deleted by keeping simultaneously pressed the UP and DOWN keys. The ESC key
is used to go back to the main menu. The picture shows a page of the list, containing both alarms and general
events.
1.3 PROGRAMMING MODE
The Settings menu gives access to programming mode. As shown below, the menu offers a list of settings next
to a window showing the default parameter set, or the one selected previously, when the pointer is moved on
the relevant options.
The menu under the cursor is accessed by pressing the RET key. This is shown by the “Enabled Menu”. Once
17
the menu is accessed, it is possible to change the value of the displayed fields or select a function by means of
the arrow keys. The RET key is used to confirm the selection (an acoustic signal should be heard). The ESC
key (or no key pressed for more than 7 seconds) sends back to the setting list. Pressing it again (or pressing
no key for more than 10 seconds) brings back to the main menu.
Every selection made in the Settings menu is stored into the EEPROM until it is changed again, this allows to
remember the settings status after an equipment reset.
Description of the submenus included in Settings.
SUBMENU
OPERATION
Clock / Date
Update the time and date shown in the main menu box.
FWD Read Mode
Selection of the analogue voltage signal (PEAK or RMS) to convert and
display the Forward power in antenna. A message in the main menu screen
confirms current choice.
Remote Control
It is possible to remotely control the apparatus, thus to monitor the parameters
shown on the display of Amplifier Control module and check the status of the
transmitter.
This is done through RS232 or RS485 standard serial communication, digital
and analog inputs through the DB25 telemetering connector on the rear panel
of the Amplifier Control module.
If the “Local” mode is set in this menu, the control module and the apparatus
can only be controlled locally, and a remote command is ignored. If “Remote”
is set instead, the REMOTE LED on the front panel of the module lights up
after going back to the main screen. From then on, incoming remote commands
from either the serial port or the telemeasuring connector on the rear panel
are handled (Note 1).
18
Serial Comm
Selects the remote control via serial port.
RS232 MODE: the RS232 mode allows a direct access to the equipment
via PC and a remote access via modem or switched telephone line.
RS485 MODE: the RS485 mode allows a remote access to the equipment
via modem over switched telephone line or GSM network. It allows the
connection to the Remote Control System, designed to monitor several
apparatuses located at the same site.
Buzzer
Enables / disables the buzzer during normal operation.
FAN Alarm
Select “OFF” to have the amplifiers turned off further to a FAN alarm; if
“ON” is selected, they will stay on.
INT Alarm
Select “OFF” to have the amplifiers turned off further to a INTERLOCK
alarm; if “ON” is selected, they will stay on.
LOG Mode
Select “only alarms” to store in the EEPROM and display in the module LOG
only detected alarms; select “all events” to store and display also any event
detected by any amplifier and sent via RS485 to the control module.
Working Timer
Updates the counter of the working time of the transmitter. Once this menu
has been enabled, the counter reset option appears in the window.
Backlight
If “Switch Off” is selected and no key is pressed for 8 minutes, the back light
of the display is turned off; select “always ON” to have it always on.
Frequency
This menu only exists in the firmware for Amplifier Control of FM transmitters.
The working frequency can be selected within a range from 88 to 108MHz,
this allows to optimise the display of the Forward power sent to the antenna.
Thresholds info
Shows for some seconds the alarms thresholds of the powers sent to the
antenna.
Release info
Shows for some seconds information concerning the transmitter and the
firmware version.
Note 1: to control the apparatus from remote, consider that pins n. 1 and n. 14 of the telemetering connector on the rear panel
of Amplifier Control module are used to receive the ON (pin n. 1) and OFF (pin n. 14) commands, both impulsive and
stationary. The digital level on these contacts is usually high, becoming low when the remote control is active. When a remote
command to turn off the amplifiers is received while the transmitters is ON, the LED ON of the frontal panel blinks.
19
1.3 POWER CALIBRATION
- FWD Power calibration
Disconnect the antenna and connect a wattmeter to the antenna connector. Give power to the amplifier until
you will read on the wattmeter a value corresponding to the equipment nominal power. Then turn the trimmer
A (see mounting plan BOTTOM - PN1071AR2, it is a variable resistor used to adjust the A analog input
measure) until you read approximately the same FWD power value on the display.
- REF Power calibration
Disconnect the antenna and connect a wattmeter to the antenna connector. Connect the Forward power
monitoring cable to the Reflected power input connector. Give power to the amplifier until you will read on the
wattmeter a value corresponding to 10% of the equipment nominal power. Then turn the trimmer B (see
mounting plan BOTTOM - PN1071AR2, it is a variable resistor used to adjust the B analog input measure)
until you read approximately the same REF power value on the display.
- UNB Calibration
Connect a wattmeter before the dummy load. Give power to the amplifier then turn off one slave module: you
will read an amount of unbalancing power on the wattmeter. Turn the trimmer C (see mounting plan BOTTOM
- PN1071AR2, it is a variable resistor used to adjust the C analog input measure) until you read approximately
the same UNB power value on the display.
1.4 RS232 AND RS485 PIN TABLES
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
Digital
Output
TX232
Digital
Input
RX2_485B-
Digital
Input
RX232
Digital
Input
RX2_485A+
GND
GND
VDC +5V
Digital
Output
TX2_485Z-
Digital
Output
TX2_485Y+
RS232 - DB9 Connector (Front panel)
20
RS485 - DB9 Connector (Rear panel)
1.5 TELEMEASURING PINS TABLE
PIN N°
SIGNAL TYPE
IN / OUT
FUNCTION
Digital
Digital
Output
Digital
Output
Digital
Output
Digital
Output
Digital
Output
Digital
Output
AGC alarm TTL:
GND = AGC alarm, +5V = no AGC alarm
Digital
Output
GND
10
Analog
Output
11
Analog
Output
12
Analog
Output
13
Analog
Output
REMOTE ON/OFF TTL:
GND = REMOTE ON
+5V = REMOTE OFF
REMOTE AMPLIFIER ON/OFF TTL:
if REMOTE ON then
GND = AMPLIFIER OFF
+5V = AMPLIFIER ON
14
Digital
Input
15
Digital
Output
16
Digital
Output
17
Digital
Output
18
Digital
Output
19
Digital
Output
AGC alarm TTL:
GND = AGC alarm, +5V = no AGC alarm
20
GND
21
+5V
22
Analog
Output
FWD Power [0,+ 5V]
23
Analog
Output
REF Power [0,+ 5V]
24
Analog
Output
UNB Power [0,+ 5V]
25
Analog
Output
21
1.6 OTHER TABLES
SYGNAL TYPE
IN/OUT
FUNCTION
Analog
Input
FWD Power monitoring
Analog
Input
REF Power monitoring
Analog
Input
UNB Power monitoring
BNC Connectors
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
GND
Digital
Output
AGC alarm TTL:
GND = AGC alarm, +5V = no AGC alarm
Digital
Output
AGC alarm TTL:
GND = AGC alarm, +5V = no AGC alarm
Analog
Output
FWD Power (range 0 - +5V)
Analog
Output
FWD Power (range 0 - +5V)
AGC Connector
22
BNC
SYGNAL TYPE
IN/OUT
Contact
Digital
Input
Body
GND
FUNCTION
FANS control Switch or TTL:
closed/GND = no FANS alarm
open/+5V = FANS alarm
FANS CONTROL Connector
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
Digital
Output
TX1_485Z-
Digital
Output
TX1_485Y-
GND
Digital
Input
RX1_485B-
Digital
Input
RX1_485A+
RS485 - DB9 Connector (Amplifiers communication)
PIN N°
SYGNAL TYPE
IN/OUT
FUNCTION
GND
VDC +24V
24VDC LOAD FAN Connector
23
Front panel
Status LEDs
Alarm LEDs
RS232 Socket
LCD Display
Function keys
RF Monitor connector
ON/OFF Switch
24
RS232
MICROPROCESSOR CONTROLLED SYSTEM
DESCRIPTION
Rear panel
RF Input connector
Main Power supply socket with Fuse-Holder by 10A
Driver1 Power socket
Driver2 Power socket
Fans Power socket
GND
Fuse by 1A
Fuse by 8A
24Vdc Connectors
10
AGC Socket
11
Telemeasures socket
12
Fans Control connector
13
RS485 Socket (Amplifiers Communication)
14
RS485 Socket (Remote Control)
15
Interlock connector
16
Power measurement connector
12
10
16
13
14
11
15
DESCRIPTION
25
Component list
APG012C - Amplifier Control
Part Name Code
Description
Qty
CON0145
05504
05525
PAN0066
CON0153
0552B
02880
SCH0239AR0
SCH0110BR0
SCH0152AR0
SCH0241AR0
E0031
07926
02843
02695
02856
07925
07524A
02018
02035
08500
02700
02790
02871A
C0814
V0761
CON0145R0 POST. CASS. CONTROLLO APG012B
CON0134R0 PIANO PROF. 260 ARE. p. 02047 ZN
LAT. 3U PROF. 260 TAV. 424/A p. 2033 ZN
PAN0066R0 PANNELLO CONTR. APG012B 3U
CON0153AR0 BASE CASS. CONTR. x APG012 ZN
KIT MANIGLIE 3-4U cod. 235.012
SPINA V.DE 10A + INT. + FUS. DA PANN. BZ15011
SCHEDA DI CONTROLLO CON DISPLAY
SCHEDA 3 IN. ANALOGICI MASTER APG012B
SCHEDA COMMUTAZIONE 220VAC x APG012B
SCHEDA IN/OUT DIGITAL SIGNAL FOR APG012C
ALIM. SWITCHING S-60-24
PROTEZIONE IN GOMMA PVC PG 087
SPINA SCHERM. 2 POLI cod. 525.2552
CONNETTORE DB9F x CAVO IU008059
CONNETTORE DB25F x CAVO 525-2812
PROTEZIONE IN GOMMA PVC PG075
INTERR. NERI I3910
GE 35145D/22 BN(UG909/cxRG174)
PRESA BNC/F x RG316 cod. 60140
CAVO RG174 50W
CONNETTORE cod. 534-2303 FEM. 16 VIE
CONNETTORE DB25M x CAVO SALDATO 525-2602
CALOTTE PER DB25 cod. 525-2622
NASTRO CONDUT. IN RAME DA 25mm 264/9275
TAPPI NERI O 12.7 PLASTICA DP-500
0,30
0,50
26
This page is intentionally blank
27
CONTROL AND DISPLAY BOARD
Component layout SCH0239AR0 (Bottom and Top layer)
28
SCH0239AR0
29
30
31
32
33
COMPONENT LIST SCH0239AR0
Part Name/Number
Description
Qty.
Comps.
BATT BH001RB 3093_90
BZ AI-155 03705
CC 100nF-S 01065C
03093 03090 BATTERY HOLDER
03705 5VDC BUZZER
01065C Y5V 1206 COND
33
CC 15pF-S 01088
CC 1nF-S 01096
01088 SMD 1206 COND
01096 SMD 1206 COND
20
CC 1uF100V-S 01760A
CC 220pF-S 01093
CC 47pF-S 01100
CE 10uF16V-S
CE 1uF50V-S 01763A
CE 220uF50V LOW ESR
CE 47uF35V-S 01790A
CE 47uF50V-S 01791C
D 1N4148-S 03002
D 50WQ06FN
D BAS85-S
D BAT54S
DIS WG240128B
DL KA-3528SGC 03057
DL LEDG3 03053
DL LEDR3 03058
DL LEDY3 03051
IC 24LC64 04815
IC 74HC00-S 4762A
IC 82B715-S 04734A
IC CD4053BC-S 04710A
IC LM2596S-5.0
IC LM75-S 00668
IC LMC6482-S
IC LMC6484-S
IC M41T56 04611
IC MAX232-S 04804B
IC MAX3080-S 04770
IC MAX3080-S N.M.
IC MAX942CSA-S
IC MB90F543PF
IC MPC100T-450I-TT
IC ULN2003A 4870
IND MS85 10uH-S
IND T100uH-1.8A 4958
01760A Y5V 1206 COND <<50 V>>
01093 SMD 1206 COND
01100 SMD 1206 COND
01626B TANT. ELETTR SMD CO
01763A ELETTR SMD COND
1799A ELETTR SMD COND LOW ESR
01790A ELETTR SMD COND
01791C ELETTR SMD COND
03002 SMD DIODE
03019A SMD DIODE SCHOTTKY 5,5A
03024 SMD DIODE SCHOTTKY
03199 SMD SCHOTTKY DIODE A-K T
03083 240/128 DOT MATRIX LCD
03057 GREEN SMD LED DIODE
03053 GREEN LED DIODE 3mm
03058 RED LED DIODE 3mm
03051 YELLOW LED DIODE 3mm
04815 SMD INTEG CIRCUIT
4762A SMD INTEG CIRCUIT
04734A SMD INTEG CIRCUIT
04710A SMD INTEG CIRCUIT
04580 SMD INTEG CIRCUIT
00668 SMD INTEG CIRCUIT
04632 SMD INTEG CIRCUIT
04634 SMD INTEG CIRCUIT
04611 SMD INTEG CIRCUIT
04804B SMD INTEG CIRCUIT
04770 SMD INTEG CIRCUIT
NOT MOUTED SMD INTEG CIRCUIT
04572 SMD INTEG CIRCUIT
04596 SMD INTEG CIRCUIT
04577 SMD INTEG CIRCUIT
04870 SMD INTEG CIRCUIT
04948 INDUCTOR 2,7A
04958 TOROIDAL-STORAGE CHOKES
BATT1
BZ1
C10, C15, C17-19, C22, C25, C28, C38,
C45, C49-52, C55, C62-63, C68-69, C78,
C80-85, C87-88, C90, C92-95
C74-75
C12-14, C31-33, C42-43, C53-54, C56-58,
C60-61, C66, C76-77, C79, C86
C21, C23, C37, C64-65, C67, C71-72
C2-9
C20, C30, C35-36, C40-41, C48, C59
C24, C26-27, C29, C34, C39, C46-47
C89, C91
C16, C44, C70, C73
C11
C1
D12-13, D17, D19
D9
D1-8
D10-11, D14-16, D18
LCD1
DL1
DL3
DL2, DL4, DL6-7
DL5
IC7
IC19
IC17
IC12
IC14
IC8
IC20
IC2-5
IC6
IC16
IC22
IC18
IC9-11, IC13
IC15
IC21
IC1, IC23
L1
L2
34
Page 1/2
Part Name/Number
Description
Qty.
Comps.
Page 2/2
INV IN-D43A-5V
J DB9_F-0° LT
J FC-10P 02697-02699
J FC-16P 02701-02700
J FC-26P 02855-02854
J PAN2 02739
J PAN2 02739-40-41
J PAN3 02707
J PAN3 NOT MOUNTED
J SCREWCONN2 02853
JU JUMP3 02707-02742
R 100R-S 00029A
R 10K-S 00053A
03085 DC/AC MODULE
02794 PCB CONNECTOR DB9 LONG T
02697+02699 PCB CONNECTOR POL
02701+02700 PCB CONNECTOR POL
02855+02854 PCB CONNECTOR POL
02739 PCB CONNECTOR
02739+02740+02741 PCB CONNECTO
02707 PCB CONNECTOR
NOT MOUNTED PCB CONNECTOR
02853 PCB SCREW CONNECTOR
02707+02742 MASCHIO PAN3
00029A RES 1/4W 5% SMD 1206
00053A RES 1/4W 5% SMD 1206
37
R 120R-S 00030A
R 1K0-S 00041A
R 1K5-S 00043A
R 22K-S 00057A
00030A RES 1/4W 5% SMD 1206
00041A RES 1/4W 5% SMD 1206
00043A RES 1/4W 5% SMD 1206
00057A RES 1/4W 5% SMD 1206
11
R 2K2-S 00045A
R 330R-S 00035B
R 33R-S 00023A
R 470K-S 00073A
R 470R-S 00037A
00045A RES 1/4W 5% SMD 1206
00035B RES 1/4W 5% SMD 1206
00023A RES 1/4W 5% SMD 1206
00073A RES 1/4W 5% SMD 1206
00037A RES 1/4W 5% SMD 1206
30
R 4K7-S 00049A
R 820R-S 00040A
RL 30.22.24 07569
RV 10K-S-H 00715
RV 1M-3266X
SW SWITCH-4DIP 90°
SW SWITCH-8DIP
T 06086 N 7630 7632
TR BC848 03457
XTAL 32.768k-S 05146
XTAL 4MHz-S 05101A
00049A RES 1/4W 5% SMD 1206
00040A RES 1/4W 5% SMD 1206
07569 RELE
00715 VARIABLE RESISTOR
00815 VARIABLE RESISTOR
07531A PCB DIP SWITCH 90°
07530A PCB DIP SWITCH SMD
7630 7632 KTI06086 PULSANTE 2
03457 NPN SMD TRANSISTOR
05146 QUARTZ
05101A QUARTZ
INV1
J6
J11, J13
J12, J14
J10
J4
J5
J1-3
J8-9
J7
JP1-4
R109, R114, R119-121, R123
R22-27, R30, R32-33, R40, R47, R50, R57,
R68, R81-82, R85, R90-101, R105-108,
R116, R118, R122, R124
R112-113
R46, R54, R87-88, R104
R110-111
R18, R20-21, R28, R34, R36, R38-39, R41,
R43-44
R19, R35, R37, R42, R45, R53, R59-60
R89, R103
R86, R102
R48-49, R51-52, R55-56, R58, R65
R10-17, R29, R31, R61-64, R66-67,
R69-80, R83-84
R117
R9
RLY1-5
R115
R1-8
SW1
SW2
T1-4
TR1
XTAL1
XTAL2
35
ANALOG INPUT BOARD
SCH0110BR0
Component layout SCH0110BR0
COMPONENT LIST SCH0110BR0
Part Name/Number
Description
Qty.
Comps.
CC 1206 N.M.
CC 1nF-S 01096
J BNC-90G-PCB 2034
J BNC-90G-PCB 2034
J FC-16P 02701-02700
R 0R0-S 00001
R 1206 N.M.
N.M. SMD 1206 COND
01096 SMD 1206 COND
02034 PCB CONNECTOR
N.M. BNC-90G
02701+02700 PCB CONNECTOR POL
00001 RES 1/4W 5% SMD 1206
N.M. RES 1/4W 5% SMD 1206
17
18
Z MICRO SOIC 8P N.M.
SMD INTEG CIRCUIT NOT MOUNTED
C4-20
C1-3
J1-3
J4-8
J9
R13, R15, R17, R19, R21, R23
R1-12, R14, R16, R18, R20, R22
R24
IC1-3
36
37
220VAC SWITCHING BOARD
SCH0152AR0
Component layout SCH0152AR0
COMPONENT LIST SCH0152AR0
Part Name/Number
Description
Qty.
Comps.
CC 2nF2 2kV 01045A
D 1N4148 03001
FUSE OMEGA C1034
J CON HD515V/05-6PVE
J FC-10P 02697-02699
J VASCHETTA IEC
JU JUMP2 02739-02742
RL 40.31.24
01045A CERAMIC COND
03001 DIODE
FUS00008 PORTA FUSIBILE 5x20 D
02883 + 02884 PANDUIT PCB CONN
02697+02699 PCB CONNECTOR POL
02879 VASCHETTA FEMALE PCB
02739+02742 MASCHIO PAN2
7567C RELE
C1-3
D1-6
F1
J1
J9
J6-8
JP1
RLY1-3
38
39
IN/OUT DIGITAL BOARD
SCH0241AR0
Component layout SCH0241AR0
COMPONENT LIST SCH0241AR0
Part Name/Number
Description
Qty.
Comps.
DZ 5V1 03109
FUSE OMEGA C1034
J BNC-90G-PCB 2034
J DB9-90G 02797
J FC-16P 02701-02700
J SCREWCONN2 02853
J TESTP2.5mm 07912
R 0R0-S 00001
R 10K 0053
R 1K0 0041
03109 ZENER DIODE
FUS00008 PORTA FUSIBILE 5x20 D
02034 PCB CONNECTOR
02797 PCB CONNECTOR
02701+02700 PCB CONNECTOR POL
02853 PCB SCREW CONNECTOR
07912 TEST POINT
00001 RES 1/4W 5% SMD 1206
0053 RES 1/4W 5%
0041 RES 1/4W 5%
DZ1
F1
J2-3
J4-6
J1
J7
J8-11
R3-9
R1
R2
40
41
S-60-24 SWITCHING POWER SUPPLY
E0031
SPECIFICATION
MODEL
S-60-24
Input voltage
Input frequency
Inrush current
Output voltage
Overload protection
Over voltage protection
Setup, rise, hold up time
85 ~ 264VAC; 120 ~ 370VAC
47-63Hz
Cold start, 30A/115V, 60A/230V
Refer to below table (±10% ADJ.)
105% ~ 150% output pulsing code
115% ~ 135% of output voltage
800ms, 50ms, 10ms/115VAC
300ms, 50ms, 80ms/230VAC
I/P-O/P:3kV, I/P-FG:1.5KV, 1min.
0-50°C@100%, -10°C@80%, 60°C@60%
UL 1012, UL 1950, TUV EN60950
EN55022 class B, EN61000-4-2,3,4,5, EN60555-2,3
5P/9.5mm pitch terminal block
0.55kgs/pcs; 30pcs/ 17kgs/ 1CUFT
Withstand voltage
Working temp
Safety standards
EMC Standards
Connection
Weight/Packing
42
Type No
Output
Tol.
R&N
Effi.
P.P.
S-60-5
S-60-12
S-60-15
S-60-24
5V, 12A
12V, 5A
15V, 4A
24V, 2.5A
± 2%
± 1%
± 1%
± 1%
120mV
120mV
150mV
150mV
73%
76%
77%
79%
58
58
58
58
43
FG
FG
AC/N
C32
221/250VAC
RTH1
10SP005
0.47U/50V
0.47U/50V
104/100V
104/100V
12V
15V
24V
30V
1U/50V
5V
C18
C21
C22
C23
U1
3842
C24
BD1
R8
22
C11
103/50V
R9
R14
C25
330U/35V
330U/35V
471/1KV
471/1KV
470U/25V
1000U/25V 1000U/25V
470u/25V
472/100V
222/500V
4A/800V
330U/35V
330U/35V BYQ28X-200
330U/35V BYQ28X-200
470U/25V BYQ28X-200
330U/35V
470U/25V BYQ28X-200
1000U/25V
CTB34M
D4
V-
470u/25V
2200U/10V 2200U/10V 2200U/10V 2200U/10V 2200U/10V
C3
472/250VAC
C6
222/250VAC
C2
472/250VAC
103/50V
C20
S-60N DIFFERENT COMPONENT:
3022
U3
R12
5K1
C28
221/250VAC
R11
7K5
C1
474/250VAC
C31
203/100V
LF1
TF-096C1
C15
FS1
F 3A/250V
R4
47K/2W
RB009
RB009
RB009
RB009
RB016
L2
2SK727
Q1
AC/L
U2
PC111
R13
1K
ZNR1
471
C12
C13
103/50V
C7
473/400V
R5
5.1
22K
15K
15K
15K
10K
R14
D2
FR104
24K
20K
12K
7K5
2K
R17
330/3W
C4
104/250VAC
471/50V
R2
C8
101/1KV
R3
30K/3W
D1
EGP20J
C9
47u/50V
2K
2K
2K
1K5
1K5
R18
T1
10-13
14-16
100
100
22
22
22
R20
U2
PC111
D4
D4
R27
390
390
220
220
100
R23
C22
C18
R19
SHR1
TL431
C20
C21
R22
2K2
R1
680K/1/2W
R10
680
C14
223/50V
R23
C23
10K
4K7
2K7
2K7
560
R26
R21
470
R29
47K/2W
R7
5K1
C16
221/1KV
C24
ZD3
JUMP
47/1/2W
47/1/2W
5.1/1/2W
5.1/1/2W
5.1/1/2W
R27
L2
C25
SVR1
1K
C5
150u/400V
C10
472/50V
R6
R17
R18
R28
ZD2
R20
1K/2W
680/2W
270/2W
270/2W
39/2W
R28
U3
3022
R26
LED1
GREEN
D8
FR104
0.39/2W
0.39/2W
0.39/2W
0.39/2W
0.33/2W
R6
C29
333/1KV
44
820
820
820
820
680
R9
C30
104/100V
TF161-1
TF161-1
TF160-1
TF159-1
TF158-1
T1
GND
+5V
ZD2
33V/1W
26.9V
17.9V
13.8V
5.1V
20K
20K
10K
10K
3K3
R19
C12
222/50V
222/50V
222/50V
222/50V
103/50V
COMPONENT LIST S-60-24
SPECIFICATIONS
QUANTITY
BOM FOR S-60-24 ON CASE
CASE 901-D-R1 M
CASE 901-T-R2 M
HS YS004W-055-R4 71268W-055
MHS002-R1 25mm
MYLAR FILM 901-R2
PR-7.5
BOX 901 168x105x45mm
SCREW F 3x6 ISO NI
SCREW F 3x18 ISO NI
SCREW T 3x6 ISO NI
SCREW P 3x6 ISO NI
LABEL UL S-60N-24-R2
LABEL IN/OUT UL BO17-R1 S-60N
CARTON 901 0.97CUFT
BOM FOR S-60-24 ON PCB
R/C 1/4W 5.1W 5% HP=10 T-52mm
R/C 1/4W 22W 5% HP=10 T-52mm
R/C 1/4W 100W 5% HP=10 T-52mm
R/C 1/4W 390W 5% HP=10 T-52mm
R/C 1/4W 470W 5% HP=10 T-52mm
R/C 1/4W 680W 5% HP=10 T-52mm
R/C 1/4W 820W 5% HP=10 T-52mm
R/C 1/4W 1kW 5% HP=10 T-52mm
R/C 1/4W 2kW 5% HP=10 T-52mm
R/C 1/4W 2.2kW 5% HP=10 T-52mm
R/C 1/4W 4.7kW 5% HP=10 T-52mm
R/C 1/4W 5.1kW 5% HP=10 T-52mm
R/C 1/4W 7.5kW 5% HP=10 T-52mm
R/C 1/4W 15kW 5% HP=10 T-52mm
R/C 1/4W 20kW 5% HP=10 T-52mm
R/C 1/2W 47W 5% T-52mm
R/C 1/2W 680kW 5% T-52mm
R/MO 2W 680W 5% KINK
R/MO 2W 47kW 5%
R/MO 3W 330W 5% MINI
R/MO 3W 30kW 5% MINI
R/NW 2W 0.39W 5%
MVR 0.3W 1kW 10% HP=5x5
NTC 4A 5W SCK054 KINK
MOV 0.6W 470V TNR15G471K
JUMP 0.6 P=10
JUMP 0.6 P=15
POSITION
HS3
HS3
HS3, HS3
HS3
HS1
CASE
30
R5
R8
R20
R23
R21
R10
R9
R13
R18
R22
R26
R12, R7
R11
R14
R17, R19
R27
R1
R28
R29, R4
R2
R3
R6
SCR1
RTH1
ZNR1
J1, J2, J3, J4, ZD3
J5
45
SPECIFICATIONS
QUANTITY
POSITION
C/Y2 221/250VAC 20% P=7.5 AC
C/Y2 222/250VAC 20% P=7.5 AC
C7Y2 472/250VAC 20% P=7.5 AC
C/X2 104/250VAC 20% P=15 KNB153X
C/X2 474/250VAC 20% P=22 KNB153X
C/M 473/400V 10% P=10
C/M 104/63V 10% P=5
C/C 101/1KV 10% P=5 Y5P
C/C 221/1KV 10% P=5 Y5P
C/C 471/100V 10% P=5 Y5P
C/C 471/1KV 10% P=5 Y5P
C/ML 222/100V 5% P=3
C/ML 472/100V 5% P=3
C/ML 103/100V 5% P=3
C/ML 203/100V 5% P=5
C/ML 223/100V 5% P=4.5
C/C 333/1KV EPOXY 20% P=10 Z5V
C/E 150u/400V 85°C 30x25 HP3
C/E 47u/50V 105°C 6.3x11 KM
C/E 330u/35V LL3K 10x16 YXG
BD 4A/600V GLASS D3SB60
FRD 1A/400V FR104 T-52mm
SFRD BYQ28X-200 10A/200V TO220F
SFRD EGP20J 2A/600V T-52mm
ZD 1/2W 26.9V 2% 27-2 T-52mm
LED GREEN 204GD-A
FET 2SK2652 6A/900V TO3P
SHR 431 2.5V 2% MM1431AT
PHOTO CNX82A PC111
PHOTO-TRIAC MOC3022
PWM TL3842P TI
RB-COIL RB009A 6x25 10. 1.5uH
LF TF096C1 EE-25 0.5 23mH
MT TF161-1-R3 EER-35
FUSE F3 L 250 5x20 G- U GFE/GMA
FUSE CLIP 5x20
TB HB 951-05P/DT49-B01W-05P
WIRE 07#18 100mm 05x05
HS HS001-R2
MHS002-R1 25mm
PCB S-60N-R5 CEM-1 20Z SS M1
SCREW F 3x12 ISO NI
SCREW P 3x6 ISO ZN
C28, C32
C6
C2, C3
C4
C1
C7
C18, C30
C8
C16
C15
C20
C12
C10
C11, C13
C31
C14
C29
C5
C9
C21, C24, C25
BD1
D2, D8
D4
D1
ZD2
LED1
Q1
SHR1
U2
U3
U1
L2
LF1
T1
FS1
FS1
TB1
F-F
HS1
HS1
PCB
Q1
HS1
46
LDMOS - UHF TV AMPLIFIER
AUTV/1500LD
User’s manual
47
This page is intentionally blank
48

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 48
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:e0c40d1d-b6cf-4a15-a9e7-e7b392a82be9
Modify Date                     : 2006:03:08 10:57:20-06:00
Create Date                     : 2006:03:08 10:57:03-06:00
Metadata Date                   : 2006:03:08 10:57:20-06:00
Document ID                     : uuid:73e873ef-286d-4e32-9f02-fed5a3c99e70
Format                          : application/pdf
Title                           : APT120A_AUTV_5000LD_Rev0_Date221003.p65
Creator                         : PageMaker 6.5
Author                          : Gianluca
Producer                        : Acrobat Distiller 3.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PHLTXUP5000

Navigation menu