EnOcean TCM2XXC 315 MHz Transceiver with optional Repeater capability User Manual CERTIFICATE OF COMPLIANCE

EnOcean GmbH 315 MHz Transceiver with optional Repeater capability CERTIFICATE OF COMPLIANCE

User Manual

Download: EnOcean TCM2XXC 315 MHz Transceiver with optional Repeater capability User Manual CERTIFICATE OF COMPLIANCE
Mirror Download [FCC.gov]EnOcean TCM2XXC 315 MHz Transceiver with optional Repeater capability User Manual CERTIFICATE OF COMPLIANCE
Document ID954069
Application IDrQH488TnRyRiZKWucaQzTw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize41.41kB (517568 bits)
Date Submitted2008-06-11 00:00:00
Date Available2008-06-11 00:00:00
Creation Date2008-06-10 11:47:32
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2008-06-10 11:47:53
Document TitleCERTIFICATE OF COMPLIANCE
Document CreatorAcrobat PDFMaker 7.0.7 for Word
Document Author: Systems Administrator

Rhein Tech Laboratories, Inc.
360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
Appendix K:
Client:
Models:
Standards:
ID’s:
Report #:
EnOcean GmbH
TCM200C & TCM220C
FCC 15.231/IC RSS-210
SZV-TCM2XXC/5713A-TCM2XXC
2008102
Manual
Please see the following pages.
Page 26 of 30
USER MANUAL
V0.92
Transceiver Module
TCM200C / 220C
June 5, 2008
Patent protected:
PRELIMINARY
WO98/36395, DE 100 25 561, DE 101 50 128,
WO 2004/051591, DE 103 01 678 A1, DE 10309334,
WO 04/109236, WO 05/096482, WO 02/095707,
US 6,747,573, US 7,019,241
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 1/24
USER MANUAL
V0.92
TCM200C / 220C
REVISION HISTORY
The following major modifications and improvements have been made to the first version of
this document:
No
0.92
0.93
Major Changes
Corrected: No internal pull-up on IN_5
Agency Certification section added
Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany
www.enocean.com, info@enocean.com, phone ++49 (89) 6734 6890
© EnOcean GmbH
All Rights Reserved
Important!
This information describes the type of component and shall not be considered as assured
characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry
and specifications are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com.
As far as patents or other rights of third parties are concerned, liability is only assumed for
modules, not for the described applications, processes and circuits.
EnOcean does not assume responsibility for use of modules described and limits its liability
to the replacement of modules determined to be defective due to workmanship. Devices or
systems containing RF components must meet the essential requirements of the local legal
authorities.
The modules must not be used in any relation with equipment that supports, directly or
indirectly, human health or life or with applications that can result in danger for people,
animals or real value.
Components of the modules are considered and should be disposed of as hazardous waste.
Local government regulations are to be observed.
Packing: Please use the recycling operators known to you. By agreement we will take packing material back if it is sorted. You must bear the costs of transport. For packing material
that is returned to us unsorted or that we are not obliged to accept, we shall have to invoice you for any costs incurred.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 2/24
USER MANUAL
V0.92
TCM200C / 220C
TABLE OF CONTENT
1.1
1.2
1.3
1.4
1.5
GENERAL DESCRIPTION ............................................................................... 4
Basic Functionality ....................................................................................... 4
Technical Data ............................................................................................ 4
Physical Dimensions .................................................................................... 5
Environmental Conditions ............................................................................. 5
Ordering Information ................................................................................... 5
FUNCTIONAL DESCRIPTION .......................................................................... 6
2.1 Block Diagram ............................................................................................ 6
2.2 Pin Description and operational characteristics ................................................. 7
2.3 Absolute maximum ratings ........................................................................... 8
2.4 Equivalent schematics .................................................................................. 9
2.4.1 Open drain outputs OUT_0..3 (TCM200C only) ............................................. 9
2.5 Transmit timing (only in repeater mode) ......................................................... 9
APPLICATIONS INFORMATION ......................................................................10
3.1 Transmission range ....................................................................................10
3.2 Mounting the antenna .................................................................................11
3.2.1 Mounting the 15cm whip antenna .............................................................11
3.2.2 Mounting 50Ω antennas ...........................................................................13
3.3 Power supply requirements ..........................................................................13
3.4 Connecting Open Collector or Open Drain Outputs ...........................................14
3.5 Transmission range ....................................................................................15
3.6 FCC/IC approval requirements............................ Error! Bookmark not defined.
DEVELOPMENT TOOLS ................................................................................19
APPENDIX .............................................................................................................20
A.1 EnOcean serial protocol ...............................................................................20
A.1.1 Message format......................................................................................20
A.1.2 Octet signals and bit order .......................................................................20
A.1.3 Description of serial data structure ............................................................21
A.1.4 Detailed description of ORG field ...............................................................21
A.1.5 Detailed description of STATUS field ..........................................................22
A.1.6 Detailed description of DATA_BYTE 3..0 fields .............................................23
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 3/24
USER MANUAL
V0.92
TCM200C / 220C
GENERAL DESCRIPTION
1.1
Basic Functionality
The transceiver modules TCM 200C and TCM 220C of EnOcean enable the realization of
highly efficient RF repeaters and transceivers for the EnOcean 315 MHz radio system. The
module receives all signals of the EnOcean radio transmitters and makes them available at
the serial port. In addition a repeater functionality can be activated. Using API200 it is possible to write custom software for the module.
TCM200C / TCM220C without antenna
1.2
Technical Data
Antenna
15cm whip antenna installed, external 50Ω antenna mountable
Frequency
315.0 MHz
Data rate / Modulation type
125 kbps / ASK
Conducted output power
typ. 5dBm
Receiver sensitivity
typ. –95 dBm
Power supply voltage
TCM200C: 5V ±5%, TCM220C 3V ±5%
Power supply current
Receive mode: typ. 29mA, max. 34mA (RX)
Transmit mode: max. 40mA (TX)
Radio standards
approvable according to FCC / IC for use in North America
Observe precautions! Electrostatic sensitive devices!
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 4/24
USER MANUAL
V0.92
TCM200C / 220C
PP5
PP4
PP3
ANT1
ANT2
PP2
Physical Dimensions
PP1
1.3
GND
IN_0
IN_1
IN_2
IN_3
IN_4
IN_5
OUT_0
OUT_1
OUT_2
OUT_3
OUT_4
RXD
n.c.
VCC
GND
GND
TCM200C/TCM220C Dimensions (mm)
PCB dimensions (without pin connector)
Pin connector
1.4
18.0 x 36.5 mm
16 pins, grid 2.0 mm (4.0 mm in length,
Environmental Conditions
Operating temperature
-25°C … +65 °C
Storage temperature
-40°C up … +85 °C
Humidity
1.5
0.5 mm)
0% … 95% r.h.
Ordering Information
Type
TCM200C
TCM220C
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Ordering Code
S3033-K200
S3033-K220
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 5/24
USER MANUAL
V0.92
TCM200C / 220C
FUNCTIONAL DESCRIPTION
2.1
Block Diagram
IN_0..5
RF
Transceiver
OUT_0..4
µC
ANT
Voltage
regulator
PP1..5
(TCM200C only)
VCC
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
GND
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 6/24
USER MANUAL
V0.92
TCM200C / 220C
2.2
Pin Description and operational characteristics
Pin
Symbol
GND
IN_0
IN_1
IN_2
IN_3
IN_4
IN_5
10
11
OUT_0
OUT_1
OUT_2
OUT_3
12
OUT_4
13
14
15
16
RXD
n.c.
VCC
GND
ANT1
ANT2
ICSP_VPP
Vcc
GND
ICSP_DATA
ICSP_CLK
PP1
PP2
PP3
PP4
PP5
Function TCM200C
Function TCM220C
Ground connection
Digital inputs 3V logic, 5V
Digital inputs, 3V logic
tolerant, internal pull-up (3V) or analog inputs 3V
Digital input, 3V logic, 5V
tolerant
Open drain output,
35 V max., 100 mA max.,
100 mW max. each.
Digital input, 3V logic
Digital output, 3V logic, 20mA max.
Digital output, 5V logic,
Digital output, 3V logic, 20mA max.
20mA max.
For EnOcean internal use only
Not used
Power supply 5V ± 5%
Power supply 3V ± 5%
Ground connection
Foot point for whip antenna
Foot point for 50Ω antenna
Programming voltage or active low reset to controller
3V internal VCC for programming interface
Ground connection for programming interface
In-circuit debugger and ICSP programming data
In-circuit debugger and ICSP programming clock
The module provides a basic firmware which is flashed at time of production.
It provides the following features:
„ Serial output of received EnOcean radio telegrams at OUT_0 (see appendix A.1)
„ Repeater activation if IN_2 LOW at startup
„ The receiver sensitivity can be controlled via IN_3:
Reduced sensitivity if IN_3 LOW, high sensitivity if IN_3 HIGH
Please use external pull-ups at the IN_2 and IN_3 of TCM220C to assure defined
input levels!
In addition EnOcean provides an API (please refer to API200 User Manual) which allows to
write customer specific firmware for the microcontroller of the module.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 7/24
USER MANUAL
V0.92
TCM200C / 220C
2.3
Absolute maximum ratings
Symbol
Description
VCC
Supply Voltage (Note 1)
OUT_0
Output 0 (Note 2)
Parameter
TCM200C
OUT_4
Units
min.
max.
min.
max.
VCC
-0.3
5.5
-0.3
3.6
Voltage
-0.3
60
-0.3
VCC+0.3
± 25
mA
Current
OUT_1..3
TCM220C
Output 1..3 (Note 2)
Voltage
Output source or sink current
Current
Max. load current
Current
Output 4 (Note 3)
Voltage
Output diode current
Current
200
-0.3
60
-0.3
± 25
mA
200
mA
-0.3
± 20
mA
Vout < -0.5 V or Vout > VCC +
0.5 V
Output source or sink current
Current
± 25
mA
IN_0..4
Input 0..4
Voltage
-0.3
-0.3
VCC+0.3
IN_5
Input 5 (SER_RX)
Voltage
-0.3
-0.3
RXD
For EnOcean internal use only!
this pin has to be left open for proper function of the device
VCCi
Internal Voltage (Note 1)
Voltage
Vpp
Programming Voltage
Voltage
-0.3
-0.3
ICSP_DATA
Programming Data
Voltage
-0.3
-0.3
ICSP_CLK
Programming Clock
Voltage
-0.3
-0.3
ANT2
50 Ohm Antenna (Note 4)
Voltage
RF power
-7
-7
dBm
Voltage
ANT1
Note 1:
Whip Antenna (Note 4)
± 25
not allowed
see VCC
on TCM200C VCCi is the internal stabilized voltage of 3V (should not be used for driving external circuitry)
on TCM220C VCCi is VCC
Note 2:
on TCM200C OUT_0..3 are Open-Drain-Outputs, max. power dissipation 300mW for OUT_0/1 and OUT_2/3 each
(dual transistor)
on TCM220C Output 0..3 are digital outputs at 3V (Low: max. 0.4V, High: min. 2.4V, see datasheet PIC18F65J11)
Note 3:
on TCM200C OUT_4 is an digital driver output at 5V
Note 4:
antenna connections are DC-shorted to ground, only for RF signal, no DC voltage should be applied
on TCM220C OUT_4 is an digital output at 3V (Low: max. 0.4V, High: min. 2.4V, see datasheet PIC18F65J11)
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 8/24
USER MANUAL
V0.92
TCM200C / 220C
2.4
Equivalent schematics
2.4.1 Open drain outputs OUT_0..3 (TCM200C only)
OUT_x
external
(OD)
2.5
OUT_x
internal
(TTL)
Transmit timing (only in repeater mode)
The setup of the transmission timing allows avoiding possible collisions with data packages
of other EnOcean transmitters as well as disturbances from the environment. With each
transmission cycle, 3 identical subtelegrams are transmitted. The transmission of a subtelegram lasts approximately 1.2 ms. To optimize data security, each telegram is repeated
twice within about 40 ms, whereas the delay between the three transmission bursts is effected at random.
Delay between received telegam and 1st subtelegram: 1 ms + n x 1 ms (integer n: 0≤n≤3)
Delay between 1st and 2nd subtelegram: 6 ms + n x 1 ms (integer n: 0≤n≤3)
Delay between 2nd and 3rd subtelegram: 18 ms + n x 1 ms (integer n: 0≤n≤11)
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 9/24
USER MANUAL
V0.92
TCM200C / 220C
APPLICATIONS INFORMATION
3.1
Transmission range
The main factors that influence the system transmission range are type and location of the
antennas of the receiver and the transmitter, type of terrain and degree of obstruction of
the link path, sources of interference affecting the receiver, and “Dead” spots caused by
signal reflections from nearby conductive objects. Since the expected transmission range
strongly depends on this system conditions, range tests should categorically be performed
before notification of a particular range that will be attainable by a certain application.
The following figures for expected transmission range are considered by using a PTM, a
STM or a TCM radio transmitter device and the TCM radio receiver device with preinstalled
whip antenna and may be used as a rough guide only:
„
„
„
„
„
Line-of-sight connections: Typically 30m range in corridors, up to 100m in halls
Plasterboard walls / dry wood: Typically 30m range, through max. 5 walls
Line-of-sight connections: Typically 30m range in corridors, up to 100m in halls
Ferroconcrete walls / ceilings: Typically 10m range, through max. 1 ceiling
Fire-safety walls, elevator shafts, staircases and supply areas should be considered as
screening.
The angle at which the transmitted signal hits the wall is very important. The effective wall
thickness – and with it the signal attenuation – varies according to this angle. Signals
should be transmitted as directly as possible through the wall. Wall niches should be
avoided. Other factors restricting transmission range:
„ Switch mounted on metal surfaces (up to 30% loss of transmission range)
„ Hollow lightweight walls filled with insulating wool on metal foil
„ False ceilings with panels of metal or carbon fiber
„ Lead glass or glass with metal coating, steel furniture
The distance between EnOcean receivers and other transmitting devices such as computers, audio and video equipment that also emit high-frequency signals should be at least
0.5m
A summarized application note to determine the transmission range within buildings is
available as download from www.enocean.com.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 10/24
USER MANUAL
V0.92
TCM200C / 220C
3.2
Mounting the antenna
Positioning and choice of receiver and transmitter antennas are the most important factors
in determining system transmission range.
TCM200C and TCM220C are providing two antenna outputs, ANT1 and ANT2:
„ ANT1 is designed for use with a 15cm whip antenna
„ ANT2 is designed for use with 50Ω antennas, e.g. helix antenna or external antenna
3.2.1 Mounting the 15cm whip antenna
For good receiver performance, great care must be taken about the space immediately
around the antenna since this has a strong influence on screening and detuning the antenna. The antenna should be drawn out as far as possible and must never be cut off. Mainly
the far end of the wire should be mounted as far away as possible (at least 15 mm) from all
metal parts, ground planes, PCB strip lines and fast logic components (e.g. microprocessors).
Do not roll up or twist the whip antenna!
Radio frequency hash from the motherboard desensitizes the receiver. Therefore:
„ PCB strip lines on the user board should be designed as short as possible
„ A PCB ground plane layer with sufficient ground vias is strongly recommended
„ See also section 3.3 for power supply requirements. Problems may especially occur with
switching power supplies!
Specification of the TCM whip antenna; L=150mm
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 11/24
USER MANUAL
V0.92
TCM200C / 220C
Recommendations for laying the antenna:
PCB with GND
PCB without GND
The GND plane should
have a size of at least
5cm x 8cm
Antenna too close
to GND area
Antenna end led
back to foot point
Antenna too close
to GND area
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 12/24
USER MANUAL
V0.92
TCM200C / 220C
3.2.2 Mounting 50Ω antennas
For mounting the receiver at bad RF locations (e.g. within a metal cabinet), an external
antenna has to be used.
„ Unsolder the whip antenna (if already mounted)
„ Connect external antenna to the module by 50Ω coax cable with Teflon insulation
„ „ Connect the inner cable to the ANT2 antenna hole on the PCB
„ „ Solder the shielding as short as possible to the antenna GND pad
(length of insulation max. 4 mm)
It is also possible to mount other 50Ω antennas – such as off the shelf helix antennas –
onto the module. In this case the GND pad is not used.
3.3
Power supply requirements
In order to provide a good radio performance, great attention must be paid to the power
supply and a correct layout and shielding. A star-connected topology and at least a 22uF
low-ESR tantalum or similar ceramic capacitor is recommended. This capacitor must be
located as close as possible to the module, between the module supply pin VCC and GND.
Furthermore, a low DC-resistance (<1Ω) EMI-suppressor is needed in series between the
board supply pin input and the output of the power supply rail. We recommend a ferrit
bead e.g. multi layer suppressor type MLS0805-4S7-102 from Ferroxcube.
The ripple on the power supply rail must be below 10 mVpp.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 13/24
USER MANUAL
V0.92
TCM200C / 220C
3.4
Connecting Open Collector or Open Drain Outputs
The term open-collector typically refers to a transistor output where the collector output
(collector for bipolar transistors, drain for MOSFETs) of the transistor is not yet connected
to a positive voltage internally. Since a transistor used in an output is typically a saturated
switch, the collector needs to be connected to a positive voltage to complete the circuit.
This positive voltage does not need to be any specific value as long as it is above the transistor saturation level. Therefore, an open collector/drain output offers more flexibility and
can be connected to a broad range of voltages using an adequate pull-up/load resistor. This
resistor is required for the output as it completes the transistor's circuit.
Applications of open-collector/drain devices:
One useful property is that the resistor does not need to be connected to the same supply
voltage: a lower or higher voltage can be used instead. Open collector/drain circuits are
therefore sometimes used to interface two devices that have different operating logic levels
(voltages) or even to directly drive higher voltage external loads (e.g. relays).
Another advantage is that more than one open-collector/drain output can be attached to a
single wire. If all outputs attached to the wire are in the high-impedance/logic 1 state, the
pull-up resistor will hold the wire in a high voltage state. If at least one of the device
outputs is in the ground/logic 0 state, it will sink current and bring the line voltage low.
15
C5
C6
11
10
R 2k2
12
15
VCC
OUT_0
VCC
GND
C2+
MAX232
T1IN
T2IN
+5V
C7
V+
C1+
C1V-
16
C2-
T1OUT
T2OUT
R1OUT
R1IN
R2OUT
R2IN
14
C8
RS232
13
TCM200C
GND
16
Example for connection of an RS232 circuit to an open collector/drain output
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 14/24
USER MANUAL
V0.92
TCM200C / 220C
+12V
+5V
15
VCC
OUT_0
TCM200C
GND
16
Example for connection of a relay to an open collector/drain output
3.5
Transmission range
The main factors that influence the system transmission range are:
o Type and location of the antennas of receiver and transmitter
o Type of terrain and degree of obstruction of the link path
o Sources of interference affecting the receiver
o “Dead” spots caused by signal reflections from nearby conductive objects
Since the expected transmission range strongly depends on these system conditions, range
tests should categorically be performed in early project phases!
The following figures for expected transmission range are considered by using a PTM, or
STM transmitter device and the TCM radio transceiver device with preinstalled whip antenna and may be used as a rough guide only:
o Line-of-sight connections: Typically 30m range in corridors, up to 100m in halls
o Plasterboard walls / dry wood: Typically 30m range, through max. 5 walls
o Brick walls / aerated concrete: Typically 20m range, through max. 3 walls
o Ferroconcrete walls / ceilings: Typically 10m range, through max. 1 ceiling
o Fire-safety walls, elevator shafts, staircases and supply areas should be considered
as screening.
The angle at which the transmitted signal hits the wall is very important. The effective wall
thickness – and with it the signal attenuation – varies according to this angle. Signals
should be transmitted as directly as possible through the wall. Wall niches should be
avoided. Other factors restricting transmission range:
o Switch mounted on metal surfaces (up to 60% loss of transmission range)
o Hollow lightweight walls filled with insulating wool on metal foil
o False ceilings with panels of metal or carbon fiber
o Lead glass or glass with metal coating, steel furniture
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 15/24
USER MANUAL
V0.92
TCM200C / 220C
The distance between EnOcean receivers and other transmitting devices such as computers, audio and video equipment that also emit high-frequency signals should be at least
1m.
A summarized application note to determine the transmission range within buildings is
available as download from www.enocean.com.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 16/24
USER MANUAL
V0.92
TCM200C / 220C
3.6 AGENCY CERTIFICATIONS
3.6.1 FCC (United States) Certification
TCM200C and TCM220C LIMITED MODULAR APPROVAL
This is an RF module approved for Limited Modular use operating as an intentional transmitting device with respect to 47 CFR 15.231(a-c) and is limited to OEM installation. The
module is optimized to operate using small amounts of energy, and may be powered by a
battery. The module transmits short radio packets comprised of control signals, (in some
cases the control signal may be accompanied with data) such as those used with alarm systems, door openers, remote switches, and the like. The module does not support continuous streaming of voice, video, or any other forms of streaming data; it sends only short
packets containing control signals and possibly data. The module is designed to comply
with, has been tested according to 15.231(a-c), and has been found to comply with each
requirement. Thus, a finished device containing the TCM200C/TCM220C radio module can
be operated in the United States without additional Part 15 FCC approval (approval(s) for
unintentional radiators may be required for the OEM’s finished product), under EnOcean’s
FCC ID number. This greatly simplifies and shortens the design cycle and development
costs for OEM integrators. The module can be triggered manually or automatically, which
cases are described below.
Manual Activation
The radio module can be configured to transmit a short packetized control signal if triggered manually. The module can be triggered, by pressing a switch, for example.
The packet contains one (or more) control signals that is(are) intended to control something at the receiving end. The packet may also contain data. Depending on how much
energy is available from the energy source, subsequent manual triggers can initiate the
transmission of additional control signals. This may be necessary if prior packet(s)
was(were) lost to fading or interference. Subsequent triggers can also be initiated as a precaution if any doubt exists that the first packet didn’t arrive at the receiver. Each packet
that is transmitted, regardless of whether it was the first one or a subsequent one, will only
be transmitted if enough energy is available from the energy source.
Automatic Activation
The radio module also can be configured to transmit a short packetized control signal
if triggered automatically, by a relevant change of its inputs or in response to receiving a
signal from another transmitter, for example. Again, the packet contains a control signal
that is intended to control something at the receiving end and may also contain data. As
above, it is possible for the packet to get lost and never reach the receiver. However, if
enough energy is available from the energy source, and the module has been configured to
do so, then another packet or packets containing the control signal may be transmitted at a
later time.
The device is designed to operate as a repeater, which can receive signals from the following list of FCC/IC approved transmitters, and retransmit the signals.
„
„
„
„
PTM200C
STM110C
TCM200C
TCM200C
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
FCC ID:SZV-PTM200C, IC:5731A-PTM-200C
FCC ID:SZV-STM110C, IC:5731A-STM-110C
FCC ID:SZV-TCM-2XXC, IC:5731A-TCM-2XXC
FCC ID:SZV-TCM-2XXC, IC:5731A-TCM-2XXC
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 17/24
USER MANUAL
V0.92
TCM200C / 220C
OEM Requirements
In order to use EnOcean’s FCC ID number, the OEM must ensure that the following conditions are met:
„
End users of products, which contain the module must not have the ability to alter the
firmware that governs the operation of the module. The agency grant is valid only when
the module is incorporated into a final product by OEM integrators.
„
The end-user must not be provided with instructions to remove, adjust or install the
module.
„
The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product.
Attaching a label to a removable portion of the final product, such as a battery cover, is
not permitted. The label must include the following text:
Contains FCC ID: SZV-TCM2XXC
The enclosed device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (i.) this device may not cause
harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.
The user manual for the end product must also contain the text given above.
„
Changes or modifications not expressly approved by EnOcean could void the user's authority to operate the equipment.
„
The module must be used with only the following approved antenna(s).
Part Number
N.A.
„
Type
Integrated Wire/Monopole
Gain
1.0 dBi
The OEM must sign the OEM Limited Modular Approval Agreement with EnOcean
3.6.2 IC (Industry Canada) Certification
Labeling requirements for Industry Canada are similar to those required by the FCC. The
Original Equipment Manufacturer (OEM) must ensure that IC labeling requirements are
met. A clearly visible label on the outside of a non-removable part of the final product must
include the following text:
Contains IC: 5731A-TCM2XXC
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 18/24
USER MANUAL
V0.92
TCM200C / 220C
DEVELOPMENT TOOLS
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 19/24
USER MANUAL
V0.92
TCM200C / 220C
APPENDIX
A.1
EnOcean serial protocol
A.1.1 Message format
The following figure shows the message format. A data block of length n is composed of 2
synchronization bytes, 1 octet for the header and n-1 octets for the message data.
TxD
Sync
Sync
Header
...
Byte0
ByteN-1
Message format for asynchronous serial communication
A.1.2 Octet signals and bit order
„
„
„
9600 bps; 8 data bits, no parity bit, one start bit, one stop bit
Line idle is binary 1 (standard)
Each character has one start bit (binary 0), 8 information bits (least significant bit first)
and one stop bit (binary 1)
Byte
5V
TxD
STA D0
D1
D2
D3
D4
D5
D6
D7 STOP
0V
Bit
Time
Bit
Time
Bit
Time
Signals and bit order sending a byte
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 20/24
USER MANUAL
V0.92
TCM200C / 220C
A.1.3 Description of serial data structure
Bit 7
Bit 0
SYNC_BYTE1 (A5 Hex)
SYNC_BYTE0 (5A Hex)
H_SEQ
LENGTH
ORG
DATA_BYTE3
DATA_BYTE2
DATA_BYTE1
DATA_BYTE0
ID_BYTE3
ID_BYTE2
ID_BYTE1
ID_BYTE0
STATUS
CHECKSUM
SYNC_BYTE 0..1
H_SEQ
LENGTH
ORG
DATA_BYTE 0..3
ID_BYTE 0..3
STATUS
CHECKSUM
(8
(3
(5
(8
(8
(8
(8
(8
bit each)
bit)
bit)
bit)
bit each)
bit each)
bit)
bit)
Synchronization Bytes
Header identification: always 0 in TCM200C/220C
Number of octets following the header octet (11 dec)
Type of telegram (see detailed description below)
Data bytes 0..3 (see detailed description below)
32-bit transmitter ID
Status field (see detailed description below)
Checksum (Last LSB from addition of all octets except
sync bytes and checksum)
A.1.4 Detailed description of ORG field
ORG field
(decimal)
Acronym
Description
RPS
1BS
4BS
HRC
Telegram from a PTM switch module received
(e.g. PTM 100 or PTM 200)
1 byte data telegram from a STM sensor module
(e.g. STM 250)
4 byte data telegram from a STM sensor module
(e.g. STM 100)
Telegram from a CTM module received
0-4, 9-255
Reserved
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 21/24
USER MANUAL
V0.92
TCM200C / 220C
A.1.5 Detailed description of STATUS field
If ORG = 5 (Telegram from a PTM switch module):
Reserved
T21
NU
RP_COUNTER
Reserved
T21
(2 bit)
(1 bit)
NU
RP_COUNTER
(1 bit)
(4 bit) =0..15
For future use
T21=0 Æ PTM switch module of type 1,
T21=1 Æ PTM switch module of type 2
NU=1 Æ N-message, NU=0 Æ U-message.
Repeater level: 0 is original message (not repeated)
IMPORTANT NOTE FOR SYSTEMS USING AN ENOCEAN RADIO REPEATER:
Within toggle switch applications using the serial receiver mode in combination
with a separate repeater, please ensure that no serial command interpretation
error may occur at the connected control unit. A toggle signal means that the
same telegram is sent for switching something on and off. If e.g. the light is
switched on receiving the I-button telegram from a PTM 200C, the repeated telegram (delay <100ms) may switch off the light again. It is therefore mandatory to
interpret the RP_COUNTER field. If a repeated telegram (RP_COUNTER>0) is received it has to be verified if the same telegram with a lower RP_COUNTER state
has already been received in the previous 100 ms. In this case the repeated message has to be discarded.
PTM switch modules of Type 2 (e.g. PTM 200C) allow interpretation of operating two buttons simultaneously:
„ N-message received Æ Only one or two pushbuttons have been pressed.
„ U-message received Æ No pushbutton was pressed when activating the energy generator, or more than two pushbuttons have been pressed.
Note for telegrams from PTM transmitters: Due to the mechanical hysteresis of the energy
bow, in most rocker switch device implementations, pressing the rocker sends an Nmessage and releasing the rocker sends a U-message!
If ORG = 6, 7 or 8 (all other telegrams):
Reserved
Reserved
RP_COUNTER
RP_COUNTER
(4 bit)
(4 bit)
For future use
Repeater level: 0 is original message (not repeated)
Please consider the “IMPORTANT NOTE” above!
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 22/24
USER MANUAL
V0.92
TCM200C / 220C
A.1.6 Detailed description of DATA_BYTE 3..0 fields
If ORG = 5 and NU = 1 (N-message from a PTM switch module):
DATA_BYTE2..0
DATA_BYTE3
always = 0
as follows:
RID
UD
RID
cimal)
UD
PR
leased
SRID
SUD
SA
PR
SRID
SUD
SA
(2 bit)
Rocker ID, from left (A) to right (D): 0, 1, 2 and 3 (de-
(1 bit)
(1 bit)
UD=1 Æ O-button, UD=0 Æ I-button
PR=1 Æ Energy bow pressed, PR=0 Æ Energy bow re-
(2 bit)
(1 bit)
(1 bit)
Second Rocker ID, from left to right: 0, 1, 2 and 3
(Second) SUD=1 Æ O-button, SUD=0 Æ I-button
SA=1 Æ Second action (2 buttons pressed
simultaneously), SA=0 Æ No second action
If ORG = 5 and NU = 0 (U-message from a PTM switch module):
DATA_BYTE2..0
DATA_BYTE3
always = 0
as follows:
BUTTONS
BUTTONS
PR
(3 bit)
Reserved
Number of simultaneously pressed buttons, as following:
PTM 100 (Type1):
0 = 0 Buttons
1 = 2 Buttons
PR
(1 bit)
Reserved
(4 bit)
PTM200 (Type2):
0 = 0 Button
1 = not possible
2 = 3 Buttons
2 = not possible
3 = 4 Buttons
3 = 3 or 4 buttons
4 = 5 Buttons
4 = not possible
5 = 6 Buttons
5 = not possible
6 = 7 Buttons
6 = not possible
7 = 8 Buttons
7 = not possible
PR = 1 Æ Energy bow pressed,
PR = 0 Æ Energy bow released
for future use
If ORG = 6 (Telegram from a 1 Byte STM sensor):
DATA_BYTE2..0
DATA_BYTE3
always = 0
Sensor data byte.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 23/24
USER MANUAL
V0.92
TCM200C / 220C
If ORG = 7 (Telegram from a 4 Byte STM sensor):
DATA_BYTE3
DATA_BYTE2
DATA_BYTE1
DATA_BYTE0
Value of third sensor analog input (AD_2)
Value of second sensor analog input (AD_1)
Value of first sensor analog input (AD_0)
Sensor digital inputs as follows:
DI_3 DI_2 DI_1 DI_0
Reserved
If ORG = 8 (Telegram from a HRC transmitter):
DATA_BYTE2..0
DATA_BYTE3
always = 0
as follows:
RID
RID
UD
PR
SR
Reserved
UD
PR
(2
(1
(1
(1
(3
bit)
bit)
bit)
bit)
bit)
SR
Reserved
Rocker ID, from left (A) to right (D): 0, 1, 2 and 3
UD=1 Æ O-button, UD=0 Æ I-button
PR=1 Æ Button pushed, PR=0 Æ Button released
SR=1 Æ Store, SR=0 Æ Recall (see note)
for future use
Note: The bit SR is used only when the lower 3 Bits from ID_BYTE0 = 0b111 (scene
switch), and RID ≠ 0 (indicates that the memory buttons M0-M5 are operated in the handheld remote control).
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
TCM200C / 220C User Manual V0.92
June 5, 2008 5:18 PM
Page 24/24

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Modify Date                     : 2008:06:10 11:47:53-07:00
Create Date                     : 2008:06:10 11:47:32-07:00
Metadata Date                   : 2008:06:10 11:47:53-07:00
Creator Tool                    : Acrobat PDFMaker 7.0.7 for Word
Format                          : application/pdf
Title                           : CERTIFICATE OF COMPLIANCE
Creator                         : Systems Administrator
Document ID                     : uuid:7f0c8ad4-14da-4fac-bd92-46d15d3332a7
Instance ID                     : uuid:1631baa9-8c34-4673-b8a3-1911f74bcd23
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Page Count                      : 25
Author                          : Systems Administrator
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SZV-TCM2XXC

Navigation menu