Everspring Industry Co SM103 Wireless Alarm System 908.42MHz User Manual
Everspring Industry Co Ltd Wireless Alarm System 908.42MHz
Users manual
from the metal surface using a plastic or wooden spacer to achieve the necessary radio range. SM103 DOOR/WINDOW DETECTOR Installation The Door/Window Detector is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks. Inclusion of this Door/Window Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules and their connected lighting when the Detector is triggered. 1. Undo and remove the fixing screw from the bottom edge of the Detector. Remove the rear cover. Adding to Z-WaveTM Network In the rear casing, there is a tamper switch which is used to carry out inclusion, exclusion or association. Put a Z-WaveTM Wireless Controller into inclusion/exclusion mode, press the tamper switch on the detector to complete the inclusion/exclusion process. 2. Fit 3 1.5V AAA batteries supplied to the battery compartment. 3. With the tamper switch not being pressed on the Detector, detach or close the magnet from the Detector, the LED on the Detector will illuminate. 4. Using the rear cover as a template, mark the positions of fixing holes on the fixed part of the frame along the opening edge opposite the hinges using screws provided. 5. Refit the Detector to the rear cover and secure with the fixing screw supplied. Do not over tighten the fixing screws as this may distort or damage the casing. 6. Fit the Magnet to the moving part of the door/window opposite the Detector using the adhesive tape or 19mm fixing screws. Tamper Switch Choosing A Mounting Location Ensure that the parallel gap between the Magnet and Detector is less than 10mm and that the matching line on the Magnet is pointing towards and aligned with the line on the Detector. The Door/Window Detector is suitable for mounting in dry interior locations only. Decide which doors/windows are to be protected by Door/Window Detectors, (usually the front and back doors as a minimum will have Door/Window Detectors fitted). Additional detectors may also be fitted where required to other vulnerable doors or windows, (e.g. garage, patio/conservatory doors etc). 7. If several windows need to be protected, adopt the wire according to the specifications as mentioned below. This should be wired to the terminal block provided in the battery compartment in series connection. The wired contact should be connected using two core (24AWG) wire of maximum length 4m. Note: Take care when fixing the Detector to a metal frame, or mounting within 1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio range of the device. If required, it may be necessary to space the magnet and detector away A cable entry cut-out is available and adjacent to the terminal block. 3. By pressing the tamper switch for more than 5 seconds, and then release it. The Detector will send an alarm command (ALARM_REPORT, Alarm Type == 0x01, Alarm Level == 0x11) to the module, of which load or the lamp plugged into the On/Off Module AN135 or Lamp Module AD130 will flash for 10 seconds. Advanced Operation Internal connection The following information is for someone that has some experience setting up a Z-Wave system or someone that has computer software running a Z-Wave controller. External wired connection Enabling/Disabling Power Saving Function (for testing) You can choose either the internal or external wired connection, both of which types cannot be in existence at the same time. When the magnet is parted or closed from the Detector for 10 seconds, the SM103 will enter the power saving mode. It can be disabled or enabled power saving function by setting Configuration Parameter # 3. Note: After removing batteries, wait for 5 seconds to refit batteries. This parameter can be configured with the value of 0 through 127, where 0 means power saving being enabled and others mean power saving being disabled. Operation 1. With the tamper switch not being pressed, the unit enters test mode, which allows the user to make a test. Detach the magnet from the Detector, the red indicator LED on the Detector will illuminate and the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130 will turn ON. It implies that the unit is working properly. PS : As long as the batteries have been refitted, the Detector will enable the power saving function automatically. Configuring the OFF Delay The Configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted is Configuration Parameter # 2. This parameter can be configured with the value of 1 through 127, where 1 means 1 second delay and 127 means 127 seconds of delay. Close the door/window by replacing the magnet to the Detector will turn OFF the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130 and the red indicator LED on the connected load or lamp will be off too. 2. When the tamper switch is pressed, the unit enters normal mode. Open the door/window to detach the magnet from the Detector will turn ON the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130. Configuring the Phase Level of ON Command The Configuration parameter that can be used to adjust the phase level of ON command is transmitted is Configuration Parameter # 1. This parameter can be configured with the value of 0 through 127. Close the door/window by replacing the magnet to the Detector will turn OFF the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130. Value 0: Set Device OFF(0x00) Value 1-99: Set Device On (1-99) Value 100-127: Set Device On to the last phase (0xFF) In normal mode with the tamper switch being pressed, the red indicator LED on the Detector will not illuminate to conserve battery life when the detector is triggered, (unless the battery is low). Note: 0xFF means the device will be on to the last phase that the device was turned This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. off. Wakeup Command Class SM103 will send a Wakeup Notification Command if it has been included into a Z-Wave network. The prerequisite is the connected Z-Wave controller needs to emit a node ID and wakeup time interval to the Detector. The SM103 will wake up every 30 minutes (default) and resend the Wakeup Notification Command unless configured for another time interval. The SM103 will stay awake for 10 seconds and then go back to sleep to conserve battery life. The time interval between Wakeup Notification Commands can be adjusted if you have a device in which that is supported. Refer to that device’s instructions. Troubleshooting Symptom Cannot carry out inclusion and association LED illuminating, but cannot control the connected modules Possible Cause 1. Run out of battery power or does not fit batteries. 2. Check if reverse battery polarity Not carry out inclusion and association Frequency interference This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Recommendation 1. Replace a new battery 2. Refit the battery with correct polarity FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Carry out inclusion and association Wait for a second to retry This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Specifications Battery 1.5V AAA size x 3 Range Up to 100 m line of sight Frequency Range WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. 908.42 MHz (US) / 868.42 MHz (EU) Contact your local government for information regarding the collection systems available. *Specifications are subject to change without notice A501110873R If electrical appliances are disposed of in landfills or dumps, hazardous substances Federal Communication Commission Interference Statement can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2007:09:21 17:46:53+08:00 Modify Date : 2007:09:24 16:02:50+08:00 Metadata Date : 2007:09:24 16:02:50+08:00 Format : application/pdf Title : untitled Document ID : uuid:9b4acd18-0a72-4d49-a188-59ee92361d0d Instance ID : uuid:d7f18816-411e-483b-b86e-2ab84a98d78c Page Count : 4EXIF Metadata provided by EXIF.tools