Farpointe Data DELTA Proximity RFID Tag Reader User Manual Delta Referece CORR

Farpointe Data Inc. Proximity RFID Tag Reader Delta Referece CORR

Users Manual

Delta Series Mifare Readers Quick Reference Guide                                                                2177 Leghorn Street                                              05465-001 Rev. 1.1                                                                Mountain View, CA  94043-1605     USA                                      1 of 2                                                                Tel: +1-650-964-2615     Fax: +1-650-988-6687                                                                 Web: http://www.farpointedata.com    E-mail: sales@pyramidseries.com The Delta Series models include the Delta3, Delta5, and Delta 6.4.  The Delta 6.4 is simply a Delta5 with a keypad attachment.  All Delta Series Readers are compliant with the following organizations:  FCC compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Changes made to this equipment that is not authorized by Farpointe Data Inc. may void the user’s authority to operate the equipment.  1.0 Cable Requirements All readers operate at up to 500 feet (152 m) of cable, using nine-conductor, shielded, stranded cable.  Per the Security Industry Association’s Wiegand specification, AWG 24 (such as Belden 9539) is the minimum gauge required for data transfer in a 500-foot run length.  However, the proper wire gauge to use must be determined by the current draw requirements of the reader, the length of the cable run, and the voltage applied to the reader.  If the reader is to be operated at 5 VDC, 5 VDC must be available at the reader (long cable runs have a voltage drop due to the resistance in the cable).  A larger gauge of wire (having less resistance) or a separate power supply near the reader may be required to ensure 5 VDC is available at the reader.  2.0 Reader Modes Delta Series readers can be configured to operate in any of the following modes: • Sector Only Mode: Reader looks for access control data in a secure sector but if no valid data is found the reader outputs nothing.  This is the default mode. • CSN Only Mode: Reader does not look for access control data in a secure sector data and simply outputs the card’s CSN. • Sector Plus CSN Mode: reader looks for access control data in a secure sector but if none is found the reader outputs the card’s CSN instead.    3.0 CSN Output Formats Delta Series readers can be configured to output the card’s CSN in any of the following ways:   • 32-bit Wiegand:  The reader outputs the 32-bit CSN as Wiegand data starting with the MSB.  This is the default mode. • 26-bit Wiegand:  The reader outputs 26-bit Wiegand data comprised of the 16 lower bits of the 32-bit CSN, fixed 8-bit facility code, and beginning and ending parity bits. Facility code defaults to 001 (Note: cutting off 16 MSBs from CSN can cause card duplication). • 34-bit Wiegand:  The reader outputs 34-bit Wiegand data comprised of the 32-bit CSN MSB first plus beginning and ending parity bits. • 40-bit Wiegand:  The reader outputs 40-bit Wiegand data comprised of the 32-bit CSN followed by an 8-bit check sum. • Magnetic Stripe (ABA Track II, clock and data, with card present): 32-bit CSN is output in ABA Track II format.  4.0 Secure Sector Access Control Data Output Formats Access control data programmed onto a secure mifare sector can be output in any of the following ways: • Wiegand (industry standard 26-bit Wiegand and custom formats) • Magnetic Stripe (ABA Track II, clock and data, with card present)  5.0 Grounding Shield (drain) continuity must run from the reader to the access panel.  Shield (drain) and reader ground must be tied together at the access panel and connect to an earth ground at one point.  6.0 Power      Reference Document  Delta Series Mifare Readers
Delta Series Mifare Readers Quick Reference Guide                                                                2177 Leghorn Street                                              05465-001 Rev. 1.1                                                                Mountain View, CA  94043-1605     USA                                      2 of 2                                                                Tel: +1-650-964-2615     Fax: +1-650-988-6687                                                                 Web: http://www.farpointedata.com    E-mail: sales@pyramidseries.com A reader may be powered by the access panel, so the reader is powered on when the access supply is powered on.  However the best case is to power the reader by a separate, linear power supply.  7.0 Voltage • Can range from 5 to 14 VDC, 12 VDC is nominal  8.0 Reader Wiring Please note that at minimum the power, ground, data 0, and data 1 lines must be connected to the access panel.  Other lines are for additional functionality.   9.0 Connections in Detail Wire Color  Line  I/O  Description Red  Reader Input voltage  Input  5 to 14 VDC Green  Wiegand data 0/ Magstripe Clock  Output   Wiegand data or ABA Track II clock White  Wiegand data 1/ Magstripe Data  Output   Wiegand data or ABA Track II data Brown  Red LED host control  Input  LED host control.  In single line LED control mode (default mode) pull line low to turn on green LED. In dual line LED mode pull line low to turn on Red LED Orange  Green LED host control  Input  LED host control, only used in dual LED mode.  In dual LED mode pull line low to turn on green LED. Blue  Audio tone host control  Input  Beeper host control.  Pull line low for beep. Purple  Read mode control  Input  Read mode host control.  Pull line low for “CSN Only” mode. Yellow  Card Present  Output (can be configured as TTL or open collector) Card present line for ABA Track II magnetic stripe output. Black  Reader Ground  Input  Reader Ground Silver  Cable shield  N/A  Cable shield (drain), should be grounded  Wire Color Function Green Blue Red Purple Brown Shield (Drain) White Yellow Black Silver Data 0 Beeper Reader Power Read Mode LED line 1 LED line 2 Data 1 Card Present Reader Ground Orange Figure 1: Wiring Connections to Access Panel Access Panel      Reference Document Delta Series Mifare Readers
Delta Series Mifare Readers Quick Reference Guide                                                                2177 Leghorn Street                                              05465-001 Rev. 1.1                                                                Mountain View, CA  94043-1605     USA                                      3 of 2                                                                Tel: +1-650-964-2615     Fax: +1-650-988-6687                                                                 Web: http://www.farpointedata.com    E-mail: sales@pyramidseries.com Mifare® is a registered trademark of Philips Electronics N.V.

Navigation menu