Farpointe Data DELTA Proximity RFID Tag Reader User Manual Delta Referece CORR

Farpointe Data Inc. Proximity RFID Tag Reader Delta Referece CORR

Users Manual

Download: Farpointe Data DELTA Proximity RFID Tag Reader User Manual Delta Referece CORR
Mirror Download [FCC.gov]Farpointe Data DELTA Proximity RFID Tag Reader User Manual Delta Referece CORR
Document ID738114
Application ID8PxHYYHmemEmwa0kaCKkig==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize3.62kB (45274 bits)
Date Submitted2006-12-13 00:00:00
Date Available2006-12-13 00:00:00
Creation Date2006-12-13 06:48:22
Producing SoftwareAcrobat Distiller 7.0.5 for Macintosh
Document Lastmod2006-12-13 06:51:19
Document TitleMicrosoft Word - Delta Referece CORR
Document CreatorWord: cgpdftops CUPS filter
Document Author: Thomas Cokenias

Delta Series Mifare Readers Quick Reference Guide
Reference Document
The Delta Series models include the Delta3, Delta5, and Delta 6.4. The Delta 6.4 is simply a Delta5 with a
keypad attachment.
All Delta Series Readers are compliant with the following organizations:
FCC compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation. Changes made to this
equipment that is not authorized by Farpointe Data Inc. may void the user’s authority to operate the equipment.
1.0
Cable Requirements
All readers operate at up to 500 feet (152 m) of cable, using nine-conductor, shielded, stranded cable. Per the
Security Industry Association’s Wiegand specification, AWG 24 (such as Belden 9539) is the minimum gauge
required for data transfer in a 500-foot run length. However, the proper wire gauge to use must be determined by
the current draw requirements of the reader, the length of the cable run, and the voltage applied to the reader.
If the reader is to be operated at 5 VDC, 5 VDC must be available at the reader (long cable runs have a voltage
drop due to the resistance in the cable). A larger gauge of wire (having less resistance) or a separate power
supply near the reader may be required to ensure 5 VDC is available at the reader.
Delta Series Mifare Readers
2.0
Reader Modes
Delta Series readers can be configured to operate in any of the following modes:
• Sector Only Mode: Reader looks for access control data in a secure sector but if no valid data is found
the reader outputs nothing. This is the default mode.
• CSN Only Mode: Reader does not look for access control data in a secure sector data and simply
outputs the card’s CSN.
• Sector Plus CSN Mode: reader looks for access control data in a secure sector but if none is found the
reader outputs the card’s CSN instead.
3.0
CSN Output Formats
Delta Series readers can be configured to output the card’s CSN in any of the following ways:
• 32-bit Wiegand: The reader outputs the 32-bit CSN as Wiegand data starting with the MSB. This is
the default mode.
• 26-bit Wiegand: The reader outputs 26-bit Wiegand data comprised of the 16 lower bits of the 32-bit
CSN, fixed 8-bit facility code, and beginning and ending parity bits. Facility code defaults to 001
(Note: cutting off 16 MSBs from CSN can cause card duplication).
• 34-bit Wiegand: The reader outputs 34-bit Wiegand data comprised of the 32-bit CSN MSB first plus
beginning and ending parity bits.
• 40-bit Wiegand: The reader outputs 40-bit Wiegand data comprised of the 32-bit CSN followed by an
8-bit check sum.
• Magnetic Stripe (ABA Track II, clock and data, with card present): 32-bit CSN is output in ABA Track
II format.
4.0
Secure Sector Access Control Data Output Formats
Access control data programmed onto a secure mifare sector can be output in any of the following ways:
• Wiegand (industry standard 26-bit Wiegand and custom formats)
• Magnetic Stripe (ABA Track II, clock and data, with card present)
5.0
Grounding
Shield (drain) continuity must run from the reader to the access panel. Shield (drain) and reader ground must be
tied together at the access panel and connect to an earth ground at one point.
6.0
Power
2177 Leghorn Street
05465-001 Rev. 1.1
Mountain View, CA 94043-1605 USA
1 of 2
Tel: +1-650-964-2615 Fax: +1-650-988-6687
Web: http://www.farpointedata.com E-mail: sales@pyramidseries.com
Delta Series Mifare Readers Quick Reference Guide
A reader may be powered by the access panel, so the reader is powered on when the access supply is powered on.
However the best case is to power the reader by a separate, linear power supply.
•
Voltage
Can range from 5 to 14 VDC, 12 VDC is nominal
8.0
Reader Wiring
Please note that at minimum the power, ground, data 0, and data 1 lines must be connected to the access panel.
Other lines are for additional functionality.
Wire Color
Function
Red
Reader Power
Green
Data 0
White
Data 1
Brown
LED line 1
Orange
LED line 2
Blue
Beeper
Purple
Read Mode
Yellow
Card Present
Black
Reader Ground
Silver
Shield (Drain)
Access
Panel
Figure 1: Wiring Connections to Access Panel
I/O
Input
Output
Description
5 to 14 VDC
Wiegand data or ABA Track II clock
Output
Wiegand data or ABA Track II data
Input
LED host control. In single line LED control
mode (default mode) pull line low to turn on
green LED. In dual line LED mode pull line
low to turn on Red LED
LED host control, only used in dual LED mode.
In dual LED mode pull line low to turn on
green LED.
Beeper host control. Pull line low for beep.
Orange
Green LED host
control
Input
Blue
Input
Purple
Audio tone host
control
Read mode control
Yellow
Card Present
Black
Silver
Reader Ground
Cable shield
Output (can be
configured as TTL or
open collector)
Input
N/A
Input
Read mode host control. Pull line low for
“CSN Only” mode.
Card present line for ABA Track II magnetic
stripe output.
Reader Ground
Cable shield (drain), should be grounded
2177 Leghorn Street
05465-001 Rev. 1.1
Mountain View, CA 94043-1605 USA
2 of 2
Tel: +1-650-964-2615 Fax: +1-650-988-6687
Web: http://www.farpointedata.com E-mail: sales@pyramidseries.com
Reference Document
9.0
Connections in Detail
Wire Color Line
Red
Reader Input voltage
Green
Wiegand data 0/
Magstripe Clock
White
Wiegand data 1/
Magstripe Data
Brown
Red LED host control
Delta Series Mifare Readers
7.0
Delta Series Mifare Readers Quick Reference Guide
Mifare® is a registered trademark of Philips Electronics N.V.
2177 Leghorn Street
05465-001 Rev. 1.1
Mountain View, CA 94043-1605 USA
3 of 2
Tel: +1-650-964-2615 Fax: +1-650-988-6687
Web: http://www.farpointedata.com E-mail: sales@pyramidseries.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Create Date                     : 2006:12:13 06:48:22-08:00
Modify Date                     : 2006:12:13 06:51:19-08:00
Creator Tool                    : Word: cgpdftops CUPS filter
Metadata Date                   : 2006:12:13 06:51:19-08:00
Format                          : application/pdf
Creator                         : Thomas Cokenias
Title                           : Microsoft Word - Delta Referece CORR
Document ID                     : uuid:038e0db8-8ab9-11db-a45e-0016cb856ad0
Instance ID                     : uuid:64b8e7c2-8ab9-11db-9b9d-0016cb856ad0
Page Count                      : 3
Author                          : Thomas Cokenias
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T8I-DELTA

Navigation menu