Feig Electronic CPRM02-ANT19 Inductive Tag Reader Module User Manual

Feig Electronic GmbH Inductive Tag Reader Module

User Manual

OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 2 of 20 Manual-M21001-3de-ID-B.docID CPR.M02/ANT19ID CPR.M02.VP/AB-CA with ID ICS.ANT19(english)
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 3 of 20 Manual-M21001-3de-ID-B.docNote© Copyright 2002 - 2006 byFEIG ELECTRONIC GmbHLange Strasse 4D-35781 Weilburg-WaldhausenTel.: +49 6471 3109-0http://www.feig.deEdition: bs/07/10/30 - manual-m21001-3de-id-b.docWith the edition of this manual, all previous editions become void. Indications made in this manual may bechanged without previous notice.Copying of this document, and giving it to others and the use or communication of the contents thereof areforbidden without express authority. Offenders are liable to the payment of damages. All rights are reservedin the event of the grant of a patent or the registration of a utility model or design.Composition of the information in this manual has been done to the best of our knowledge. FEIGELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in thismanual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.The installation instructions given in this manual are based on advantageous boundary conditions. FEIGELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in thismanual  and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH doesnot convey any license under its patent rights nor the rights of others.OBID® and OBID i-scan® is a registered trademark of FEIG ELECTRONIC GmbH.I-CODE® and mifare® is a registered trademark of Philips Electronics N.V.my-d® is a registered trademark of Infineon Technologies AGTag-itTM is a registered trademark of Texas Instruments Incorporated
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 4 of 20 Manual-M21001-3de-ID-B.docContents1.  Safety Instructions / Warning - Read before start-up ! 52.  Performance Characteristics of the ID CPR.M02 Reader 62.1.  Performance Characteristics .............................................................................................62.2.  Available module and antenna types ................................................................................62.3.  Scope of delivery.................................................................................................................63.  Installation and wiring 73.1.  Dimensions..........................................................................................................................73.2.  Wiring ...................................................................................................................................83.2.1.  Supply voltage ...............................................................................................................93.2.2.  RS232 interface...........................................................................................................103.2.3.  Data/Clock interface ....................................................................................................113.2.4.  Connection of an external Antenna (ID ISC.ANT19) ...................................................123.2.5.  Optional Module ID SAM.M02 .....................................................................................133.3.  Display elements...............................................................................................................143.4.  Operating elements...........................................................................................................153.4.1.  Operating/Programming Mode: Jumper J1..................................................................153.4.2.  Retuning the internal antenna (ID CPR.M02.VP/AB-C)...............................................163.5.  Installation notes...............................................................................................................183.5.1.  Metallic surroundings...................................................................................................183.5.2.  EMC effects on cables.................................................................................................183.5.3.  EMC effects from magnetic fields................................................................................194.  Radio Approvals 204.1.  Europe (CE)........................................................................................................................204.2.  USA (FCC)..........................................................................................................................205.  Technical Data 21
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 5 of 20 Manual-M21001-3de-ID-B.doc1. Safety Instructions / Warning - Read before start-up !• The device has to be used only for the purpose designed by the manufacturer.• The operation manual has to be stored available at any time and has to be handed over toeach user.• Unauthorized changes and the use of spare parts and additional devices which have not beensold or recommended by the manufacturer may cause fire, electric shocks or injuries. Suchmeasures will lead to exclusion of any liability by the manufacturer.• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are validfor the device. The manufacturer is not legally responsible for incorrect, unsuitable manual orautomatical setting of parameters for a device or the incorrect application of a device.• Repairs can only be executed by the manufacturer.• Installation-, operation- and maintenance procedures should only be carried out by qualifiedpersonnel.• Before opening the device, the power supply must always be interrupted. Make sure that thedevice is without voltage by measuring. CAUTION! The fading of an operation control (LED) isno indicator for an interrupted power supply or the device being without voltage!• Works at the device and its installation have to be executed according to the national legalrequirements and local prescriptions.• When working on devices the valid safety regulations must be observed.
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 6 of 20 Manual-M21001-3de-ID-B.doc2. Performance Characteristics of the ID CPR.M02 Reader2.1. Performance CharacteristicsThe ID CPR.M02 Reader Module is designed for reading and writing passive transponders havingan operating frequency of 13.56 MHz. It is suitable for any application in which short read rangesand small reader dimensions are required.2.2. Available module and antenna typesThe following module types are currently available:Modul Type Power Supply Antenna RS232-TTLInterfaceData-/ClockInterfaceID CPR.M02.VP/AB-C internalID CPR.M02.VP/AB-CA5 V DCexternal4.800, 9.600,19.200, 38.400,57.600, 115.200,230.400 BaudMag. StripeWiegandThe following antenna types are currently available:Antenna DescriptionID ISC.ANT19 PCB- Antenna, 50Ω, Ø 19mm 2.3. Scope of deliveryThe following components are included:Modul Type IncludedID CPR.M02.VP/AB-C 1 x Reader Module ID CPR.M02.VP/AB-CID CPR.M02.VP/AB-CA 1 x Reader Module ID CPR.M02.VP/AB-CA
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 7 of 20 Manual-M21001-3de-ID-B.doc3. Installation and wiring3.1. DimensionsFig. 3.1-1 shows the dimensions of the ID CPR.M02 Reader ModuleFig. 3.1-1: Dimensions of the ID CPR.M02 Reader ModuleX1J1V2V1C31544,050,026,12,1Ø3,3Ø3,3Ø3,3Ø3,314,011,5X3X444,050,0C405X224,03,5
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 8 of 20 Manual-M21001-3de-ID-B.doc3.2. WiringFig. 3.2-1 and Table 3.2-1 show the pin assignments for Terminal X1. The pin connector is de-signed for flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spac-ing.Fig. 3.2-1: Pin assignments for Terminal X1DescriptionX1Pin no. Function ID CPR.M021DAT Data line for the data/clock interface2CLK Clock line for the data/clock interface3TxD RS232-TTL – Transmit Data4GND ** GND5RxD RS232-TTL – Receive Data6--- not connected7CLS CLS line for the data/clock interface8VCC + 5 V DC *9GND ** GND10 --- not connected*  Use only regulated DC power supplies !**  GND-Pins 4 and 9 are to be connected directly to each other           on the Reader ModuleTable 3.2-1: Pin assignments for Terminal X1X1J1V2V1C315X112435796810X3X4C405X2
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 9 of 20 Manual-M21001-3de-ID-B.doc3.2.1. Supply voltageThe ID CPR.M02 must be supplied only by a regulated power supply. If switching power suppliesare used with the module, be sure that there is adequate filtering. Noise from the power supply canresult in a reduction of the read/write range of the module. The cable length from the power supplyshould be as short as possible, and should in any case not exceed 3 m.DescriptionX1Pin no. Function ID CPR.M028VCC * + 5 V DC ± 5%9, 4 GND ** GND*  Use only regulated power supplies !**  GND-Pins 4 and 9 are to be connected directly to each       other on the Reader ModuleTable 3.2.1-1: Pin assignments for X1NOTE:• Reversing the polarity of the supply voltage may destroy the device.• Supply voltages outside the specifications may destroy the device.
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 10 of 20 Manual-M21001-3de-ID-B.doc3.2.2. RS232 interfaceThe length of the cable to the RS232 interface should be kept as short as possible, and must inany case not exceed 3 m.DescriptionX1Pin no. Function ID CPR.M023TxD * RS232-TTL - Transmit Data4, 9 GND ** GND5RxD * RS232-TTL - Receive Data*  Signal names as seen by the Reader Module.**  GND-Pins 4 and 9 are to be connected directly to each       other on the Reader ModuleTable 3.2.2-1: Pin assignments for the RS232 interface on X1The transmission parameters for the interface can be software-configured. Table 3.2.2-2 shows thestandard parameters for the RS232 interface.Parameter Standard settingBaud rate 38400No. of data bits 8Parity EvenNo. of stop bits 1Table 3.2.2-2: Standard parameters of the RS232 interface.
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 11 of 20 Manual-M21001-3de-ID-B.doc3.2.3. Data/Clock interfaceThe length of the cable to the data/clock interface should be kept as short as possible. It must notexceed 3 m.DescriptionX1Pin no. Function ID CPR.M021DAT Data line for the data/clock in-terface2CLK Clock line for the data/clockinterface7CLS CLS line for the data/clock in-terface4, 9   GND * GND*  GND-Pins 4 and 9 are to be connected directly to each       other on the Reader ModuleTable 3.2.3-1: Pin configuration for the RS232 interface on Terminal X1Fig. 3.2.3-1: Connecting the data/clock interfaceHost ID CPR.M02DATCLKCLSGNDDataGNDClockCLS
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 12 of 20 Manual-M21001-3de-ID-B.doc3.2.4. Connection of an external Antenna (ID ISC.ANT19)The ID CPR.M02.VP/AB-CA are intended for the connection of an external 50Ω-Antenna.The use of the integrated antenna is not possible with this version. Fig. 3.2.4-1 and Table 3.2.4-1 shows the pin assignments for Terminal X2 for the connection of theexternal antenna. The pin connector has a pin spacing of 2.54mm.Fig. 3.2.4-1: Pin assignment of Terminal X2DescriptionX2Pin no. Function ID CPR.M02.VP/AB--CA1Signal Signal pin of the external 50Ω-Antenna2GND GND pin of the external 50Ω-AntennaTable 3.2.4-1: Pin assignment of Terminal X2Fig. 3.2.4-2: Ext. 50Ω antenna ID ISC.ANT19X1J1V2V1C315X3X4X2 Connectorext. AntennaGNDSignal }12C405X2
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 13 of 20 Manual-M21001-3de-ID-B.doc3.2.5. Optional Module ID SAM.M02If needed, the optional device ID SAM.M02 can be connected to terminals X3 and X4. TheID SAM.M02 is a module for connecting and driving an additional SAM and provides security byusing cryptographic data transmission between the reader and transponder.Fig. 3.2.4-1: Dimensions of ID CPR.M02 with ID SAM.M02V2V150,0X1X3X425,010,011,5C315
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 14 of 20 Manual-M21001-3de-ID-B.doc3.3. Display elementsThe ID CPR.M02 Reader Module has a green LED (V1) and a red LED (V2) which are used asdisplay elements (Fig. 3.3-1).Fig. 3.3-1: Position of LEDs V1 and V2LED Color Standard settingV1 Green• Flashes 4x after a reset.• Flashes continuously at a frequency of2 Hz.V2 Red• Flashes 4x after a reset.• Comes on for 1 second after successfulcommunication with a transponder.Table 3.3-1: Standard setting for the LEDsNOTE:Up from Firmware-Version 1.08 the function of the red LED is connected to X1, Pin7 (CLS).For current limitation an additional resistor with 470 Ω is required. X1J1V2V1 X4
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 15 of 20 Manual-M21001-3de-ID-B.doc3.4. Operating elements3.4.1. Operating/Programming Mode: Jumper J1Jumper J1 is used to configure the operating and programming mode of the ID CPR.M02.In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then innormal operating mode.If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset. Sincethe reader’s firmware however also has a software bootloader, the hardware bootloader optionshould be used only if necessary.For additional information about programming the reader, see the corresponding Application Note„Firmware Update“.Jumper position Mode1 - 2 Standard setting :The reader is in normal operating mode.2 - 3Activation of the hardware bootloader:After a reset the reader’s CPU starts its hardwarebootloader, which can then be used for new pro-gramming.Table 3.4.1-1: Jumper J1Fig. 3.4.1-1: Jumper J1X1J1V2V1C315X3X4 Default21J13C405
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 16 of 20 Manual-M21001-3de-ID-B.doc3.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-C)The antenna of the ID CPR.M02.VP/AB-C can be detuned as a result of various ambient condi-tions such as nearby metal objects (see Section 8.5). This detuning can be compensated to somedegree using the trim capacitor C315.Fig. 3.4.3-1: Trim capacitor for retuning the antennaThe integrated antenna can be retuned with the aid of an oscilloscope (bandwidth ≥ 20 MHz). Todo this, short the GND terminal of the oscilloscope probe with the probe point and hold it over thecircuit board of the ID CPR.M02. The probe then forms a measuring loop for the radiated magneticfield of the ID CPR.M02. The distance between the oscilloscope probe and the ID CPR.M02 shouldbe between 0 and 3 cm.Use the software command „RF-ON“ (0x6A) to turn on the HF field of the ID CPR.M02. A 13.56MHz signal should be visible on the oscilloscope screen. To tune the internal antenna, now set the signal amplitude of the 13.56 MHz signal to maximumusing trim capacitor C315.Fig. 3.4.3-2: Configuration for tuning the internal antennaX1J1V2V1C315X3X4C405Trim capacitor C315:Retuning the integrated antennaTrim capacitor C405:DO NOT CHANGE !!!ID CPR.M02V1 V2X1C65Turn C315 to set amplitude to maximum
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 17 of 20 Manual-M21001-3de-ID-B.docUse caution when the maximum value of the signal amplitude is reached at the minimum or maxi-mum position of the trim capacitor (Fig. 3.4.3-3). This usually means the antenna is too severelydetuned by the surroundings and can no longer be fully compensated by the trim capacitor.BeschriftungMinimaleKapazität MaximaleKapazitätFig. 3.4.3-3: Minimum and maximum position of the trim capacitor C315After the antenna has bee tuned, check it again for maximum range and any communication gaps.NOTE:• Notwithstanding the possibility of retuning the antenna as described here, the distancebetween the reader and the surrounding metal surfaces must be at least 3 cm. Note thateven other circuit boards may act like metal objects depending on how much copperthey contain.LabelingMinimumcapacitanceMaximumcapacitance
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 18 of 20 Manual-M21001-3de-ID-B.doc3.5. Installation notesBe aware of the following possible environmental factors when installing an ID CPR.M02 into an-other device :• Effects from nearby metal objects⇒ Detuning of the integrated antenna⇒ Impaired propagation of the antenna’s magnetic field• EMC effects on cables⇒ Impaired communication between reader and transponder• EMC effects from magnetic fields⇒ Impaired communication between reader and transponder3.5.1. Metallic surroundingsWhen installing an ID CPR.M02 into another device, be sure that there are no metal surfaces orobjects in the direct vicinity of the reader if possible. These can detune the antenna and thus re-duce the magnetic field of the integrated antenna. This will in turn result in reduced read distancesfor the reader. The distance between the reader and a metal surface should be at least 3 cm. Note thateven other circuit boards may act line metal objects depending on how much copper theycontain.If a metallic surrounding cannot be avoided, stable function should at least be ensured by keepingthe distance as great as possible.The area between the antenna and transponder as well as the area on the other side of the trans-ponder should also be kept clear of metal parts.Since any change in the metallic environment will result in detuning of the integrated antenna andtherefore to impaired function, no moving metal parts, such as metallic fans, should be allowed inthe vicinity of the reader.3.5.2. EMC effects on cablesIn spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage canresult in impairment of the communication between the reader and transponder.When installing an ID CPR.M02 into another device, be sure therefore that a clean, noise-freepower supply is used.
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 19 of 20 Manual-M21001-3de-ID-B.doc3.5.3. EMC effects from magnetic fieldsSince in this type of RFID-Technology the communication between the reader and transpondertakes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the an-tenna can have a negative impact on its function.Sources of such magnetic interference fields include coils within a primary or secondary switchingpower supply.When determining the position of the reader and antenna within a device, check the device for anypossible sources of interference as described above. If necessary, use shielding to suppress suchinterference.
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 20 of 20 Manual-M21001-3de-ID-B.doc4. Radio Approvals4.1. Europe (CE)When used according to regulation, this radio equipment conforms with the basic requirements ofArticle 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99.Equipment Classification according ETSI EN 300 330: Class 24.2. USA (FCC)FCC ID    PJMCPRM02-ANT19This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that maycause undesired operation.Any changes or modifications not expressly approved by the party responsible for com-pliance could void the user's authority to operate the equipment.This device is labeled with an FCC ID number.If this label is not visible when installed in an end device, the outside of the device MUSTalso display a label referring to the enclosed module.Wording on the label similar to the following shall be used:This device contains transmitter module FCC ID    PJMCPRM02-ANT19At the time of this printing, the antennas listed below were the only antennas approved foruse with the ID CPR.M02 module. Use of other antennas must be approved byFEIG ELECTRONIC GmbH.Antennas approved: ID ISC.ANT19The FCC sticker is glued at the package.ID CPR.M02/ANT19FEIG ELECTRONICFCC ID  PJMCPRM02-ANT19
OBID® classic-pro Installation ID CPR.M02/ANT19FEIG ELECTRONIC GmbH Page 21 of 20 Manual-M21001-3de-ID-B.doc5. Technical Data• Dimensions ( W x H x D ) 50 mm x 50 mm x 14 mm• Connector 10 pol. Pin-Connector (grid dim. 2,54 mm)• Supply voltage  5 V DC ± 5% ripple0...250 kHz < 10 mVppab 250 kHz < 0,1 mVpp• Power Consumption max. 1,5 W• Operating Frequency 13.56 MHz• RF Transmitting Power 250 mW  ± 2 dB• Antenna: ID CPR.M02.VP/AB-CA External (separate 2 pol. Pin-Connector)• RS232-TTL Interface:ID CPR.M02.VP/AB-C / -CA 4.800 to 230.400 Baud• Daten-/Takt Interface • Magnet Stripe  Emulation• Wiegand Emulation• EEPROM (for parameters) 1 kB (10,000 write cycles)• FLASH 64 kB (software update on interface possible)• Supported Transpondersread and write• ISO14443-A compatible(e. g. mifare, mifare Ultra Light, my-d proximity)• ISO14443-B compatible• ISO15693 compatible(e. g. I•Code SLI, Tag-It HFI, my-d vicinity, STMLRI512)•  I•Code 1 (optional)• Security Function (optional) SAM (Security Access Module),e.g. for my-d vicinity and my-d proximity• Optical Indicators LED green: running;LED red: Transponder detected• Temperature Range OperatingStorage-20°C to +70°C-40°C to +85°C• Radio Approval EuropeUSAEN 300 330FCC  47 CFR Part 15• EMC EN 301 489• Safety EN 60950

Navigation menu