Feig Electronic CPRM02-ANT19 Inductive Tag Reader Module User Manual
Feig Electronic GmbH Inductive Tag Reader Module
User Manual
OBID® classic-pro Installation ID CPR.M02/ANT19 ID CPR.M02/ANT19 ID CPR.M02.VP/AB-CA with ID ICS.ANT19 (english) FEIG ELECTRONIC GmbH Page 2 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 Note © Copyright 2002 - 2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de Edition: bs/07/10/30 - manual-m21001-3de-id-b.doc With the edition of this manual, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID® and OBID i-scan® is a registered trademark of FEIG ELECTRONIC GmbH. I-CODE® and mifare® is a registered trademark of Philips Electronics N.V. my-d® is a registered trademark of Infineon Technologies AG Tag-itTM is a registered trademark of Texas Instruments Incorporated FEIG ELECTRONIC GmbH Page 3 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 Contents 1. Safety Instructions / Warning - Read before start-up ! 2. Performance Characteristics of the ID CPR.M02 Reader 2.1. Performance Characteristics .............................................................................................6 2.2. Available module and antenna types ................................................................................6 2.3. Scope of delivery.................................................................................................................6 3. Installation and wiring 3.1. Dimensions ..........................................................................................................................7 3.2. Wiring ...................................................................................................................................8 3.2.1. Supply voltage ...............................................................................................................9 3.2.2. RS232 interface ...........................................................................................................10 3.2.3. Data/Clock interface ....................................................................................................11 3.2.4. Connection of an external Antenna (ID ISC.ANT19) ...................................................12 3.2.5. Optional Module ID SAM.M02 .....................................................................................13 3.3. Display elements ...............................................................................................................14 3.4. Operating elements...........................................................................................................15 3.4.1. Operating/Programming Mode: Jumper J1..................................................................15 3.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-C)...............................................16 3.5. Installation notes...............................................................................................................18 3.5.1. Metallic surroundings...................................................................................................18 3.5.2. EMC effects on cables.................................................................................................18 3.5.3. EMC effects from magnetic fields ................................................................................19 4. Radio Approvals 20 4.1. Europe (CE)........................................................................................................................20 4.2. USA (FCC) ..........................................................................................................................20 5. Technical Data FEIG ELECTRONIC GmbH 21 Page 4 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 1. Safety Instructions / Warning - Read before start-up ! • The device has to be used only for the purpose designed by the manufacturer. • The operation manual has to be stored available at any time and has to be handed over to each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such measures will lead to exclusion of any liability by the manufacturer. • The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer is not legally responsible for incorrect, unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device. • Repairs can only be executed by the manufacturer. • Installation-, operation- and maintenance procedures should only be carried out by qualified personnel. • Before opening the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. CAUTION! The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being without voltage! • Works at the device and its installation have to be executed according to the national legal requirements and local prescriptions. • When working on devices the valid safety regulations must be observed. FEIG ELECTRONIC GmbH Page 5 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 2. Performance Characteristics of the ID CPR.M02 Reader 2.1. Performance Characteristics The ID CPR.M02 Reader Module is designed for reading and writing passive transponders having an operating frequency of 13.56 MHz. It is suitable for any application in which short read ranges and small reader dimensions are required. 2.2. Available module and antenna types The following module types are currently available: Modul Type Power Supply ID CPR.M02.VP/AB-C Antenna RS232-TTL Interface internal 4.800, 9.600, 19.200, 38.400, 57.600, 115.200, 230.400 Baud 5 V DC ID CPR.M02.VP/AB-CA external Data-/Clock Interface Mag. Stripe Wiegand The following antenna types are currently available: Antenna ID ISC.ANT19 Description PCB- Antenna, 50Ω, Ø 19mm 2.3. Scope of delivery The following components are included: Modul Type Included ID CPR.M02.VP/AB-C 1 x Reader Module ID CPR.M02.VP/AB-C ID CPR.M02.VP/AB-CA 1 x Reader Module ID CPR.M02.VP/AB-CA FEIG ELECTRONIC GmbH Page 6 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3. Installation and wiring 3.1. Dimensions Fig. 3.1-1 shows the dimensions of the ID CPR.M02 Reader Module 50,0 44,0 V1V2 Ø X4 3,3 X1 ,3 Ø3 C405 44,0 X2 2,1 24,0 3,5 26,1 50,0 J1 C315 X3 Ø3,3 11,5 14,0 Ø3,3 Fig. 3.1-1: Dimensions of the ID CPR.M02 Reader Module FEIG ELECTRONIC GmbH Page 7 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.2. Wiring Fig. 3.2-1 and Table 3.2-1 show the pin assignments for Terminal X1. The pin connector is designed for flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spacing. X1 10 V1V2 X4 X1 C405 J1 X2 C315 X3 Fig. 3.2-1: Pin assignments for Terminal X1 Description X1 Pin no. Function DAT Data line for the data/clock interface CLK Clock line for the data/clock interface TxD RS232-TTL – Transmit Data GND ** GND RxD RS232-TTL – Receive Data --- not connected CLS CLS line for the data/clock interface VCC + 5 V DC * GND ** GND 10 --- not connected ** ID CPR.M02 Use only regulated DC power supplies ! GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2-1: Pin assignments for Terminal X1 FEIG ELECTRONIC GmbH Page 8 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.1. Supply voltage The ID CPR.M02 must be supplied only by a regulated power supply. If switching power supplies are used with the module, be sure that there is adequate filtering. Noise from the power supply can result in a reduction of the read/write range of the module. The cable length from the power supply should be as short as possible, and should in any case not exceed 3 m. Description X1 Pin no. Function VCC * + 5 V DC ± 5% 9, 4 GND ** GND ** ID CPR.M02 Use only regulated power supplies ! GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.1-1: Pin assignments for X1 NOTE: • Reversing the polarity of the supply voltage may destroy the device. • Supply voltages outside the specifications may destroy the device. FEIG ELECTRONIC GmbH Page 9 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.2. RS232 interface The length of the cable to the RS232 interface should be kept as short as possible, and must in any case not exceed 3 m. X1 Pin no. Description Function 4, 9 ** ID CPR.M02 TxD * RS232-TTL - Transmit Data GND ** GND RxD * RS232-TTL - Receive Data Signal names as seen by the Reader Module. GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.2-1: Pin assignments for the RS232 interface on X1 The transmission parameters for the interface can be software-configured. Table 3.2.2-2 shows the standard parameters for the RS232 interface. Parameter Standard setting Baud rate 38400 No. of data bits Parity Even No. of stop bits Table 3.2.2-2: Standard parameters of the RS232 interface. FEIG ELECTRONIC GmbH Page 10 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.3. Data/Clock interface The length of the cable to the data/clock interface should be kept as short as possible. It must not exceed 3 m. Description X1 Pin no. Function DAT Data line for the data/clock interface CLK Clock line for the data/clock interface CLS CLS line for the data/clock interface 4, 9 GND * GND ID CPR.M02 GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.3-1: Pin configuration for the RS232 interface on Terminal X1 Data Clock CLS GND Host DAT CLK CLS GND ID CPR.M02 Fig. 3.2.3-1: Connecting the data/clock interface FEIG ELECTRONIC GmbH Page 11 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.4. Connection of an external Antenna (ID ISC.ANT19) The ID CPR.M02.VP/AB-CA are intended for the connection of an external 50Ω-Antenna. The use of the integrated antenna is not possible with this version. Fig. 3.2.4-1 and Table 3.2.4-1 shows the pin assignments for Terminal X2 for the connection of the external antenna. The pin connector has a pin spacing of 2.54mm. V1V2 X4 X1 C405 J1 X2 Signal GND Connector ext. Antenna X2 C315 X3 Fig. 3.2.4-1: Pin assignment of Terminal X2 Description X2 Pin no. Function Signal Signal pin of the external 50Ω-Antenna GND GND pin of the external 50Ω-Antenna ID CPR.M02.VP/AB--CA Table 3.2.4-1: Pin assignment of Terminal X2 Fig. 3.2.4-2: Ext. 50Ω antenna ID ISC.ANT19 FEIG ELECTRONIC GmbH Page 12 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.5. Optional Module ID SAM.M02 If needed, the optional device ID SAM.M02 can be connected to terminals X3 and X4. The ID SAM.M02 is a module for connecting and driving an additional SAM and provides security by using cryptographic data transmission between the reader and transponder. V1 V2 X4 50,0 X1 C315 X3 11,5 10,0 25,0 Fig. 3.2.4-1: Dimensions of ID CPR.M02 with ID SAM.M02 FEIG ELECTRONIC GmbH Page 13 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.3. Display elements The ID CPR.M02 Reader Module has a green LED (V1) and a red LED (V2) which are used as display elements (Fig. 3.3-1). V1 V2 X4 X1 J1 Fig. 3.3-1: Position of LEDs V1 and V2 LED Color Standard setting V1 Green • Flashes 4x after a reset. • Flashes continuously at a frequency of 2 Hz. Red • Flashes 4x after a reset. • Comes on for 1 second after successful communication with a transponder. V2 Table 3.3-1: Standard setting for the LEDs NOTE: Up from Firmware-Version 1.08 the function of the red LED is connected to X1, Pin7 (CLS). For current limitation an additional resistor with 470 Ω is required. FEIG ELECTRONIC GmbH Page 14 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.4. Operating elements 3.4.1. Operating/Programming Mode: Jumper J1 Jumper J1 is used to configure the operating and programming mode of the ID CPR.M02. In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then in normal operating mode. If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset. Since the reader’s firmware however also has a software bootloader, the hardware bootloader option should be used only if necessary. For additional information about programming the reader, see the corresponding Application Note „Firmware Update“. Jumper position Mode 1-2 Standard setting : The reader is in normal operating mode. 2-3 Activation of the hardware bootloader: After a reset the reader’s CPU starts its hardware bootloader, which can then be used for new programming. Table 3.4.1-1: Jumper J1 J1 V1V2 X4 X1 Default C405 J1 C315 X3 Fig. 3.4.1-1: Jumper J1 FEIG ELECTRONIC GmbH Page 15 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-C) The antenna of the ID CPR.M02.VP/AB-C can be detuned as a result of various ambient conditions such as nearby metal objects (see Section 8.5). This detuning can be compensated to some degree using the trim capacitor C315. V1V2 X4 X1 Trim capacitor C405: C405 J1 C315 X3 DO NOT CHANGE !!! Trim capacitor C315: Retuning the integrated antenna Fig. 3.4.3-1: Trim capacitor for retuning the antenna The integrated antenna can be retuned with the aid of an oscilloscope (bandwidth ≥ 20 MHz). To do this, short the GND terminal of the oscilloscope probe with the probe point and hold it over the circuit board of the ID CPR.M02. The probe then forms a measuring loop for the radiated magnetic field of the ID CPR.M02. The distance between the oscilloscope probe and the ID CPR.M02 should be between 0 and 3 cm. Use the software command „RF-ON“ (0x6A) to turn on the HF field of the ID CPR.M02. A 13.56 MHz signal should be visible on the oscilloscope screen. To tune the internal antenna, now set the signal amplitude of the 13.56 MHz signal to maximum using trim capacitor C315. Turn C315 to set amplitude to maximum ID CPR.M02 V1 V2 X1 C65 Fig. 3.4.3-2: Configuration for tuning the internal antenna FEIG ELECTRONIC GmbH Page 16 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 Use caution when the maximum value of the signal amplitude is reached at the minimum or maximum position of the trim capacitor (Fig. 3.4.3-3). This usually means the antenna is too severely detuned by the surroundings and can no longer be fully compensated by the trim capacitor. Labeling Beschriftung Minimum Minimale Kapazität capacitance Maximum Maximale Kapazität capacitance Fig. 3.4.3-3: Minimum and maximum position of the trim capacitor C315 After the antenna has bee tuned, check it again for maximum range and any communication gaps. NOTE: • Notwithstanding the possibility of retuning the antenna as described here, the distance between the reader and the surrounding metal surfaces must be at least 3 cm. Note that even other circuit boards may act like metal objects depending on how much copper they contain. FEIG ELECTRONIC GmbH Page 17 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.5. Installation notes Be aware of the following possible environmental factors when installing an ID CPR.M02 into another device : • Effects from nearby metal objects ⇒ Detuning of the integrated antenna ⇒ Impaired propagation of the antenna’s magnetic field • EMC effects on cables ⇒ Impaired communication between reader and transponder • EMC effects from magnetic fields ⇒ Impaired communication between reader and transponder 3.5.1. Metallic surroundings When installing an ID CPR.M02 into another device, be sure that there are no metal surfaces or objects in the direct vicinity of the reader if possible. These can detune the antenna and thus reduce the magnetic field of the integrated antenna. This will in turn result in reduced read distances for the reader. The distance between the reader and a metal surface should be at least 3 cm. Note that even other circuit boards may act line metal objects depending on how much copper they contain. If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping the distance as great as possible. The area between the antenna and transponder as well as the area on the other side of the transponder should also be kept clear of metal parts. Since any change in the metallic environment will result in detuning of the integrated antenna and therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in the vicinity of the reader. 3.5.2. EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an ID CPR.M02 into another device, be sure therefore that a clean, noise-free power supply is used. FEIG ELECTRONIC GmbH Page 18 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 3.5.3. EMC effects from magnetic fields Since in this type of RFID-Technology the communication between the reader and transponder takes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the antenna can have a negative impact on its function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. FEIG ELECTRONIC GmbH Page 19 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 4. Radio Approvals 4.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. Equipment Classification according ETSI EN 300 330: Class 2 4.2. USA (FCC) FCC ID PJMCPRM02-ANT19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device is labeled with an FCC ID number. If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used: This device contains transmitter module FCC ID PJMCPRM02-ANT19 At the time of this printing, the antennas listed below were the only antennas approved for use with the ID CPR.M02 module. Use of other antennas must be approved by FEIG ELECTRONIC GmbH. Antennas approved: ID ISC.ANT19 The FCC sticker is glued at the package. ID CPR.M02/ANT19 FEIG ELECTRONIC FCC ID PJMCPRM02-ANT19 FEIG ELECTRONIC GmbH Page 20 of 20 Manual-M21001-3de-ID-B.doc OBID® classic-pro Installation ID CPR.M02/ANT19 5. Technical Data • Dimensions ( W x H x D ) 50 mm x 50 mm x 14 mm • Connector 10 pol. Pin-Connector (grid dim. 2,54 mm) • Supply voltage 5 V DC ± 5% • Power Consumption max. 1,5 W • Operating Frequency 13.56 MHz • RF Transmitting Power 250 mW ± 2 dB • Antenna: ID CPR.M02.VP/AB-CA ripple 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp External (separate 2 pol. Pin-Connector) • RS232-TTL Interface: ID CPR.M02.VP/AB-C / -CA 4.800 to 230.400 Baud • Daten-/Takt Interface • • • EEPROM (for parameters) 1 kB • FLASH 64 kB (software update on interface possible) • Supported Transponders read and write • Magnet Stripe Emulation Wiegand Emulation (10,000 write cycles) • • ISO14443-A compatible (e. g. mifare, mifare Ultra Light, my-d proximity) ISO14443-B compatible ISO15693 compatible (e. g. I•Code SLI, Tag-It HFI, my-d vicinity, STM LRI512) • I•Code 1 (optional) • Security Function (optional) SAM (Security Access Module), e.g. for my-d vicinity and my-d proximity • Optical Indicators LED green: running; LED red: Transponder detected • Temperature Range • Radio Approval • EMC EN 301 489 • Safety EN 60950 FEIG ELECTRONIC GmbH Operating -20°C to +70°C Storage -40°C to +85°C Europe EN 300 330 USA FCC 47 CFR Part 15 Page 21 of 20 Manual-M21001-3de-ID-B.doc
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 20 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:108b9289-3094-4ca8-8836-d5e9e82a775e Producer : Acrobat Distiller 6.0.1 (Windows) Company : FEIG ELECTRONIC GmbH Creator Tool : Acrobat PDFMaker 6.0 für Word Modify Date : 2007:10:30 12:03:06+01:00 Create Date : 2007:10:30 12:02:28+01:00 Metadata Date : 2007:10:30 12:03:06+01:00 Document ID : uuid:1403cb83-140b-49c5-864e-694e22f81469 Format : application/pdf Title : Creator : Michael Rödig Author : Michael RödigEXIF Metadata provided by EXIF.tools