Feig Electronic MR200 Inductive Reader User Manual M40400 1de ID B
Feig Electronic GmbH Inductive Reader M40400 1de ID B
Contents
- 1. Users Manual
- 2. Users Manual Antenna 1
- 3. Users Manual Antenna 2
Users Manual
® OBID i-scan MONTAGE INSTALLATION ID ISC.MR200 (deutsch / english) public (B) 2005-02-02 M40400-1de-ID-B.doc DEUTSCH OBID i-scan® Montage / Installation ID ISC.MR200 ENGLISH deutsche Version english version from page 4 FEIG ELECTRONIC GmbH Seite 2 von 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 ENGLISH Note Copyright 2005 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. ® ® OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. ® my-d is a registered trademark of Infineon Technologies AG ® I-CODE is a registered trademark of Philips Electronics N.V. TM Tag-it is a registered trademark of Texas Instruments Incorporated. FEIG ELECTRONIC GmbH Page 4 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 Safety Instructions / Warning - Read before start-up ! Features of the Reader Family ID ISC.MR200 2.1 Features.......................................................................................................................8 2.2 Available Reader models............................................................................................8 2.3 Scope of delivery ........................................................................................................9 Installation and Wiring 3.1 10 Installation .................................................................................................................10 3.1.1 Seal caps ....................................................................................................................11 3.1.2 Cover stays .................................................................................................................11 3.1.3 Decorative covers .......................................................................................................11 Wiring terminals......................................................................................................................12 3.3 Antenna connection..................................................................................................13 3.4 Supply voltage...........................................................................................................14 3.5 DC voltage on the RF antenna terminal X2 .............................................................16 3.6 Inputs .........................................................................................................................17 3.6.1 Optocoupler ................................................................................................................17 3.7 Outputs ......................................................................................................................19 3.7.1 Optocouplers...............................................................................................................19 3.7.2 Relay...........................................................................................................................20 3.8 Interfaces ...................................................................................................................21 3.8.1 RS232 interface ..........................................................................................................21 3.8.1.1 Wiring assignments .......................................................................................22 3.8.2 Ethernet interface(ID ISC.MR200-E) ...........................................................................23 Operating and Display Elements 4.1 24 LED´s .........................................................................................................................24 FEIG ELECTRONIC GmbH Page 5 of 30 M40400-1de-ID-B.doc ENGLISH Contents OBID i-scan® Montage / Installation Startup 5.1 ID ISC.MR200 25 Port configuration .....................................................................................................25 5.1.1 RS485 (ID ISC.MR200-A) ...........................................................................................26 5.1.1.1 Setting RS485 addresses for bus operation ..................................................26 ENGLISH 5.1.2 Ethernet Interface(ID ISC.MR200-E) ...........................................................................27 Technical Specifications 6.1 28 Approval ....................................................................................................................30 6.1.1 Europe (CE) ................................................................................................................30 6.1.2 USA (FCC)..................................................................................................................30 FEIG ELECTRONIC GmbH Page 6 of 30 M40400-1de-ID-B.doc OBID i-scan® ID ISC.MR200 Safety Instructions / Warning - Read before start-up ! • The device may only be used for the intended purpose designed by for the manufacturer. • The operation manual should be conveniently kept available at all times for each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. • The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. • Repairs may only be executed by the manufacturer. • Installation, operation, and maintenance procedures should only be carried out by qualified personnel. • Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . • When working on devices the valid safety regulations must be observed. FEIG ELECTRONIC GmbH Page 7 of 30 M40400-1de-ID-B.doc ENGLISH Montage / Installation OBID i-scan® 2.1 Montage / Installation ID ISC.MR200 Features of the Reader Family ID ISC.MR200 Features ENGLISH The Reader is designed for reading passive data carriers, so-called „smart labels“, with an operating frequency of 13.56 MHz. The ID ISC.MR200 is suitable for any application in which medium-range read distances are required. An additional external antenna is required which must be connected to the reader. An anti-collision function allows simultaneous reading of multiple transponders. The Reader electronics are housed in a rigid, powder-coated aluminum enclosure with an IP54 protection rating for use outdoors. It includes two digital inputs, two digital outputs and a relay output. The Reader has an asynchronous RS232 interface. Depending on the Reader model you can choose from between an additional asynchronous interface (RS485 for the ID ISC.MR200-A) and an Ethernet interface (ID ISC.MR200-E). The interface on the ID ISC.MR200-A can be configured for operation on a data bus with RS485 interface. The Reader address can then be software assigned. A DC voltage can be applied to the antenna output. This voltage powers the Dynamic Antenna Tuner (ID ISC.DAT). 2.2 Available Reader models The following Readers are currently available: Reader model Description ID ISC.MR200-A Asynchronous interfaces RS232 and RS485 ID ISC.MR200-E Asynchronous interface RS232 and Ethernet Interface Table 2-1: Reader models FEIG ELECTRONIC GmbH Page 8 of 30 M40400-1de-ID-B.doc OBID i-scan® 2.3 Montage / Installation ID ISC.MR200 Scope of delivery Module type Scope of delivery ID ISC.MR200-A 1 x Reader ID ISC.MR200-A 3 x jumpers 2 x seal cap M16 2 x decorative cover, clip-on 2 x integrated cover stays ID ISC.MR200-E 1 x Reader ID ISC.MR200-E 1 x jumper 4 x seal cap M12 - M25 1 x seal cap - reducer 2 x decorative cover, clip-on 2 x integrated cover stays ENGLISH The following components are included in the scope of delivery: Table 2-2: Scope of delivery FEIG ELECTRONIC GmbH Page 9 of 30 M40400-1de-ID-B.doc OBID i-scan® ID ISC.MR200 Installation and Wiring Installation The Reader is designed for wall mount, including outdoors. Holes are provided in the housing for wall attachment. The housing does not need to be opened for installation on a wall (see Fig. 1). Antenna Output Input Com Power 110 200 182 60 ENGLISH 3.1 Montage / Installation RFID by FEIG ELECTRONIC Fig. 3-1: Housing ID ISC.MR200 Cable gland Size Clamping range [mm] Description M 16 4.5 – 10 Antenna cable M 16 4.5 – 10 Relay / Outputs M 16 4.5 – 10 Inputs M 12 3.5 – 7 Interface (serial) M 12 3.5 – 7 Supply voltage M 25 9 – 17 Ethernet Interface (model –E only) Table 3-1: ID ISC.MR200 cable glands FEIG ELECTRONIC GmbH Page 10 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 3.1.1 Seal caps The seal caps included in the scope of delivery can be used to close off unused cable fittings. 3.1.2 Cover stays The two cover stays can be used to attach the cover to the housing. The cover stays are inserted into the openings provided for this purpose. Fig. 3-2: Cover stay 3.1.3 Decorative covers The decorative covers are attached after installing the Reader. The slot on the long side of the cover is used for disassembling the cover. Use a screwdriver to remove the cover. Fig. 3-3: Decorative cover FEIG ELECTRONIC GmbH Page 11 of 30 M40400-1de-ID-B.doc ENGLISH The reducing ring provided is intended for the network connection. The slotted reducer is placed over the network cable and then fixed in place in the cable gland. OBID i-scan® 3.2 Montage / Installation ID ISC.MR200 Wiring terminals X9 ENGLISH J10 X2 J3 J2 J1 X8 X10 V5 V4 V3 V2 V1 J9 J8 J7 J6 J5 J4 K1 X4 2 1 X5 2 1 X3 2 1 X7 X6 2 1 2 1 X1 2 1 Fig. 3-4: Wiring terminals Fig. 3-5: Maximum cable configuration (shown: ID ISC.MR200-E) FEIG ELECTRONIC GmbH Page 12 of 30 M40400-1de-ID-B.doc OBID i-scan® 3.3 Montage / Installation ID ISC.MR200 Antenna connection An SMA socket is provided on the circuit board for connecting the external antenna. The maximum tightening torque of the SMA sockets is 0.45 Nm. Terminal X2 ENGLISH Caution: Greater tightening torque will destroy the connector. Description External antenna connection (input impedance 50Ω) Table 3-2: Connecting the external antenna Notes: • The input impedance of the antenna should be calibrated to a value of 50 Ω ± (3 Ω ∠ 3°). • The optimal operating Q of the antenna should be in a range of QO = 20...30. To determine the operating Q, the antenna must be supplied with a 50Ω source, such as a network analyzer or a frequency generator. • When connecting the antenna be sure that the permissible limits specified by national code with respect to RF installations are not exceeded. • To meet national code with respect to RF installations, each antenna feed line must be equipped with the supplied ∅ 28 mm x 20 mm EMC ferrite ring core. The antenna line must be wrapped tightly around the EMC ferrite ring core at least 4 times. The distance between the Reader connection and the ring core should be no greater than 20 cm (see Fig. 3.2.-1). max. 20cm Fig. 3-6: Antenna cable with EMC ferrite ring core FEIG ELECTRONIC GmbH Page 13 of 30 M40400-1de-ID-B.doc OBID i-scan® 3.4 Montage / Installation ID ISC.MR200 Supply voltage Connect the 12-24 VDC supply voltage to Terminal X1. ENGLISH The cable length between the power supply and the Reader module must not exceed 3 m. Terminal Abbreviation Description X1 / Pin 1 Vcc Vcc – supply voltage X1 / Pin 2 GND Ground – supply voltage Table 3-3: Supply voltage pin assignments ID ISC.MR200 Vcc GND X3 Fig. 3-7: Connecting the supply voltage Note: • Reversing the polarity of the supply voltage may destroy the unit. FEIG ELECTRONIC GmbH Page 14 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 Recommended power supplies : The power supply should be a Safety Extra-Low Voltage (SELV) type with limited power. The output power of the power supply should be at least 15 watts. Output voltage 12 - 24 VDC Output power ≥ 15 W Ripple < 150 mVpp Switching frequency < 300 kHz Table 3-4: Electrical specifications for external power supply Model Manufacturer MPP15 CEAG AG / FRIWO Group Von-Liebig-Straße 11 D- 48346 Ostbevern Germany Tel.: + 49 (0) 02532/ 81-158 www.friwo.de AC adapter MiniLine ML 30.100 PULS GmbH MiniLine ML 30.102 Arabellastraße 15 D-81925 München DIN rail mount Germany Tel.: +49 (0) 89 9278 0 www.puls-power.com Table 3-5: Recommended power supplies FEIG ELECTRONIC GmbH Page 15 of 30 M40400-1de-ID-B.doc ENGLISH To make full use of the performance capability of the Reader module, a sufficiently regulated and noise-free power supply (noise ripple = max. 150 mV) should be used. When using a switching power supply be sure that the internal switching frequency of the power supply is less than 300 kHz. OBID i-scan® 3.5 Montage / Installation ID ISC.MR200 DC voltage on the RF antenna terminal X2 ENGLISH Jumper J10 can be used to provide DC voltage on antenna terminal X2. This DC offset is used to power the dynamic antenna tuner (ID DAT). Note: • The DC voltage is intended only for power the ID ISC.DAT dynamic antenna tuner • Connecting other antennas to this DC voltage will destroy them J10 X2 Fig. 3-8: Position Jumper J10 J10 1-2 2-3 DC voltage on antenna terminal No (Default) Yes Table 3-6: Jumper J10 configuration FEIG ELECTRONIC GmbH Page 16 of 30 M40400-1de-ID-B.doc OBID i-scan® 3.6 Montage / Installation ID ISC.MR200 Inputs The optocoupler inputs in Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied. The input LEDs for the optocouplers are switch internally with a series resistor of 500 Ω. For supply voltages of greater than 10V the input current must be limited to max. 20 mA by an additional external series resistor (see Table 3.4-1). Terminal Abbreviation Description IN1+ + Input 1 IN1- - Input 1 IN2+ + Input 2 IN2- - Input 2 Table 3-7: Optocoupler input pin assignments Notes: • The inputs are configured for a maximum input current of 24 V DC and an input current of maximum 20 mA. • Reversing the polarity or overloading the inputs will destroy them. • The Reader supply voltage must not be used to drive the inputs, since otherwise additionally induced noise may reduce the effective reading range. ID ISC.MR200 X5 Rint Rint IN1+ IN1- IN2+ IN2- Rext Rext Uext. Uext. Fig. 3-9: Internal and possible external wiring of the optocoupler inputs FEIG ELECTRONIC GmbH Page 17 of 30 M40400-1de-ID-B.doc ENGLISH 3.6.1 Optocoupler OBID i-scan® Montage / Installation ID ISC.MR200 ENGLISH Fehler! Verweisquelle konnte nicht gefunden werden. shows the required external series resistances at various external voltages Uext. External voltage Uext Required external series resistor Rext 5 V ... 10 V --- 11 V ... 15 V 270 Ω 16 V ... 20 V 560 Ω 21 V ... 24 V 820 Ω Table 3-8: Required external series resistance Rext FEIG ELECTRONIC GmbH Page 18 of 30 M40400-1de-ID-B.doc OBID i-scan® 3.7 Montage / Installation ID ISC.MR200 Outputs The transistor connections of the two optocoupler outputs, collector and emitter, are galvanically isolated from the Reader electronics and brought out with no internal circuitry to Terminal X6. The outputs must therefore be powered with an external power supply. Terminal Abbreviation Description O1-C Collector – Output 1 O1-E Emitter – Output 1 O2-C Collector – Output 2 O2-E Emitter – Output 2 Table 3-9: Optocoupler output pin configuration Notes: • The outputs are configured for max. 24 V DC / 30 mA. • Reversing the polarity or overloading the outputs will destroy them. • The outputs are intended for switching resistive loads only. ID ISC.MR200 O1-C X3 O1-E O2-C O2-E Uext. Uext. Fig. 3-10:: Internal and possible external wiring of the optocoupler outputs FEIG ELECTRONIC GmbH Page 19 of 30 M40400-1de-ID-B.doc ENGLISH 3.7.1 Optocouplers OBID i-scan® Montage / Installation ID ISC.MR200 3.7.2 Relay ENGLISH A changeover relay is provided. Terminal Abbreviation Description COM Working contact NC Normally closed NO Normally open Table 3-10: Relay output pinouts Notes: • The relay outputs are configured for max. 24 V DC / 2 A. • The relay outputs are intended for switching resistive loads only. If an inductive load is used, the relay contacts must be protected by means of an external protection circuit. ID ISC.MR200 X4 COM NC NO Uext. Fig. 3-11: Internal and possible external wiring of the relay output FEIG ELECTRONIC GmbH Page 20 of 30 M40400-1de-ID-B.doc OBID i-scan® 3.8 Montage / Installation ID ISC.MR200 Interfaces 3.8.1 RS232 interface ENGLISH The RS232 interface is connected at Terminal X6. The transmission parameters are configured using software protocol. Pin assignments X6 (RS232 interface): Terminal Abbreviation Description GND RS232 – GND RxD RS232 - RxD TxD RS232 - TxD Table 3-11: RS232 interface pin assignments 9-pol. DUB-D-Buchse ID ISC.MR200 X6 GND RxD TxD PC X6 / 1 X6 / 2 X6 / 1 <−> <−> <−> Pin 5 Pin 3 Pin 2 Fig. 3-12: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 21 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 3.8.1.1 Wiring assignments The RS485 interface is connected at Terminal X7. ENGLISH Pin assignments X7 (RS485 interface): Terminal Abbreviation Description GND A- RS485 – (A -) B+ RS485 – (B +) Y- n.c. Z+ n.c. RS485 – (B +) RS485 – GND Table 3-12: RS485 interface pin assignments ID ISC.MR200 X7 RS485 - GND RS485 - (A-) RS485 - (B+) nc nc Fig. 3-13: Wiring the RSR485 interface FEIG ELECTRONIC GmbH Page 22 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 3.8.2 Ethernet interface(ID ISC.MR200-E) Cat 5 cable should be used for structured cabling. This ensures reliable operation at 10Mbps or 100Mbps. Pin assignments X8 (network interface): Terminal Abbreviation Description TX+ Transmit Data + TX- Transmit Data - RX+ Receive Data + VETH+ n.c. VETH+ n.c. RX- VETH- n.c. VETH- n.c. Receive Data - Table 3-13: Ethernet interface pin assignments FEIG ELECTRONIC GmbH Page 23 of 30 M40400-1de-ID-B.doc ENGLISH The Reader has an integrated 10/100Tbase network interface with RJ-45 connection. Terminal X8 serves as the Ethernet port. OBID i-scan® ENGLISH 4.1 Montage / Installation ID ISC.MR200 Operating and Display Elements LED´s Fehler! Verweisquelle konnte nicht gefunden werden. shows the configuration of the LED’s. Abbreviation LED V1 (green) LED V2 (blue) LED V3 (yellow Description "RUN-LED" Indicates proper running of the internal Reader software Flashing frequency approx. 1 Hz Diagnostic 1: RF communication / EEPROM status Short flashing indicates errorless communication with a transponder on the RF interface Flashes alternately with V1 after the reset following a software update Flashes alternately with V1 if an error in reading the parameters occurred following a reset Diagnostic 2: Host communication Short flashing indicates a protocol is being sent to the host. LED V4 (yellow) Diagnostic 3: for future applications LED V5 (red) Diagnostic 4: Reader initializing / RF error Comes on during Reader initializing following power-on or after a reset. Comes on when there is an error in the RF section of the Reader. The error type can be read via software using the Reader Diagnostic command [0x6E]. Table 4-1: LED configuration FEIG ELECTRONIC GmbH Page 24 of 30 M40400-1de-ID-B.doc OBID i-scan® 5.1 ID ISC.MR200 Startup Port configuration Both Reader ports can be used for communication. The Reader automatically detects which port is being used for communication. The RS232 port is used as a service port and thus has higher priority. If communication takes place on the RS232 port, the other port (RS485 for ID ISC.MR200A and network port for ID ISC.MR-200-E) is disabled for a time of 10 seconds. This lockout can be cancelled by means of a reset. Fehler! Verweisquelle konnte nicht gefunden werden. shows the standard configuration of the RS232 port. Baud rate 38400 Frame 8E1 Table 5-1: Standard configuration of the RS232 port FEIG ELECTRONIC GmbH Page 25 of 30 M40400-1de-ID-B.doc ENGLISH Montage / Installation OBID i-scan® Montage / Installation ID ISC.MR200 5.1.1 RS485 (ID ISC.MR200-A) ENGLISH In the case of the RS485 interface, any necessary termination resistors can be enabled by inserting jumpers J4, J5 and J6. Jumper In Out J4 Pull-Up on RS485 - B without Pull-Up on RS485 - B J5 Pull-Down on RS485 - A without Pull-Down on RS485 – A J6 Termination resistor without termination resistor RS485 - A ⇔ RS485 - B RS485 - A ⇔ RS485 - B Table 5-2: RS485 termination resistors 500 Ohm J4 100 Ohm J6 J5 500 Ohm Fig. 5-1: RS485 port jumpers 5.1.1.1 Setting RS485 addresses for bus operation The Reader allows you to assign the required bus address via software. Addresses are assigned by the host computer. The software is used to assign addresses between “0” and “254”. Note: Since all Readers are factory set with address 0, they must be connected and configured in succession. FEIG ELECTRONIC GmbH Page 26 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 5.1.2 Ethernet Interface(ID ISC.MR200-E) Note: The Readers must be connected to the network and configured in succession. Fehler! Verweisquelle konnte nicht gefunden werden. shows the standard configuration of the network connection. Network Address IP address 192.168.10.10 Subnet mask 255.255.255.0 Port 10001 Table 5-3: Standard configuration of the network connection FEIG ELECTRONIC GmbH Page 27 of 30 M40400-1de-ID-B.doc ENGLISH The prerequisite for using TCP/IP protocol is that each device on the network have a unique IP address. All Readers have been assigned a factory default IP address. OBID i-scan® Montage / Installation ID ISC.MR200 Technical Specifications Mechanical Data • Enclosure Die-case aluminum, powder-coated, ENGLISH lockable hinged cover • Dimensions ( W x H x D ) 200 x 110 x 60 mm • Weight 1.0 kg • Enclosure rating IP 54 • Color RAL 7040 (similar to window grey) Electrical Data • Supply voltage 12 VDC to 24VDC ± 5 % Noise Ripple : max. 150 mV • Power consumption max. 13 VA • Operating frequency 13.56 MHz • Transmitting power 1 W / 1.75W ± 1 dB • Degree of modulation 20% ± 3% absolute • Antenna connection 1 x SMA socket (50Ω) • Outputs: - 2 optocoupler - 1 relay ( 1 x changeover) 24 V DC / 30 mA (galvanically isolated) 24 V DC / 2 A • Inputs – 2 optocoupler max. 24 V DC/ 20 mA • Interfaces - ID ISC.MR200-A - ID ISC.MR200-E FEIG ELECTRONIC GmbH RS232 and RS485 RS232 and Ethernet Page 28 of 30 M40400-1de-ID-B.doc OBID i-scan® Montage / Installation ID ISC.MR200 • EEPROM (for parameters) 10,000 write cycles • FLASH Software can be updated on interface • Supported transponders • • ISO15693 (I•Code SLI, Tag-it HFI, my-d, STM LRI512) I•Code MID and EPC-Transponder • Address setting for interface (ID ISC.MR200-A only) • Optical indicators - Software (up to 254 addresses) 5 LED´s for diagnosing the operating status Ambient Conditions • Temperature range - Operating - Storage -20°C to +60°C -25°C to +85°C • Vibration EN60068-2-6 10 Hz to 150 Hz : 0.075 mm / 1 g • Shock EN60068-2-27 Acceleration : 30 g Applicable Standards • RF approval - Europe - USA • EMC EN 300 330 FCC 47 CFR Part 15 EN 301 489 • Safety - Low Voltage - Human Exposure FEIG ELECTRONIC GmbH EN 60950 EN 50364 Page 29 of 30 M40400-1de-ID-B.doc ENGLISH Functional Properties OBID i-scan® 6.1 Montage / Installation ID ISC.MR200 Approval ENGLISH 6.1.1 Europe (CE) When properly used, the RF system is in conformance with the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1995/5/EC of March 99. Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489 6.1.2 USA (FCC) FCC ID: PJMMR200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Page 30 of 30 M40400-1de-ID-B.doc
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Creator : FinePrint : Microsoft Word - M40400-1de-... (30 pages) Create Date : 2005:02:02 10:25:33 Title : M40400-1de-ID-B.doc Author : fiedler Producer : Acrobat PDFWriter 5.0 für Windows NT Modify Date : 2005:02:04 11:04:11+01:00 Page Count : 30EXIF Metadata provided by EXIF.tools