Feig Electronic MR200 Inductive Reader User Manual M40400 1de ID B

Feig Electronic GmbH Inductive Reader M40400 1de ID B

Users Manual

Download: Feig Electronic MR200 Inductive Reader User Manual M40400 1de ID B
Mirror Download [FCC.gov]Feig Electronic MR200 Inductive Reader User Manual M40400 1de ID B
Document ID527649
Application IDtdYhZKE22ERa78FzLhdPzg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize23.76kB (296964 bits)
Date Submitted2005-03-30 00:00:00
Date Available2005-03-30 00:00:00
Creation Date2005-02-02 10:25:33
Producing SoftwareAcrobat PDFWriter 5.0 für Windows NT
Document Lastmod2005-02-04 11:04:11
Document TitleM40400-1de-ID-B.doc
Document CreatorFinePrint : Microsoft Word - M40400-1de-... (30 pages)
Document Author: fiedler

®
OBID i-scan
MONTAGE
INSTALLATION
ID ISC.MR200
(deutsch / english)
public (B)
2005-02-02
M40400-1de-ID-B.doc
DEUTSCH
OBID i-scan®
Montage / Installation
ID ISC.MR200
ENGLISH
deutsche Version
english version from page 4
FEIG ELECTRONIC GmbH
Seite 2 von 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
ENGLISH
Note
 Copyright 2005 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions. FEIG
ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
®
®
OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH.
®
my-d is a registered trademark of Infineon Technologies AG
®
I-CODE is a registered trademark of Philips Electronics N.V.
TM
Tag-it is a registered trademark of Texas Instruments Incorporated.
FEIG ELECTRONIC GmbH
Page 4 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
Safety Instructions / Warning - Read before start-up !
Features of the Reader Family ID ISC.MR200
2.1
Features.......................................................................................................................8
2.2
Available Reader models............................................................................................8
2.3
Scope of delivery ........................................................................................................9
Installation and Wiring
3.1
10
Installation .................................................................................................................10
3.1.1 Seal caps ....................................................................................................................11
3.1.2 Cover stays .................................................................................................................11
3.1.3 Decorative covers .......................................................................................................11
Wiring terminals......................................................................................................................12
3.3
Antenna connection..................................................................................................13
3.4
Supply voltage...........................................................................................................14
3.5
DC voltage on the RF antenna terminal X2 .............................................................16
3.6
Inputs .........................................................................................................................17
3.6.1 Optocoupler ................................................................................................................17
3.7
Outputs ......................................................................................................................19
3.7.1 Optocouplers...............................................................................................................19
3.7.2 Relay...........................................................................................................................20
3.8
Interfaces ...................................................................................................................21
3.8.1 RS232 interface ..........................................................................................................21
3.8.1.1 Wiring assignments .......................................................................................22
3.8.2 Ethernet interface(ID ISC.MR200-E) ...........................................................................23
Operating and Display Elements
4.1
24
LED´s .........................................................................................................................24
FEIG ELECTRONIC GmbH
Page 5 of 30
M40400-1de-ID-B.doc
ENGLISH
Contents
OBID i-scan®
Montage / Installation
Startup
5.1
ID ISC.MR200
25
Port configuration .....................................................................................................25
5.1.1 RS485 (ID ISC.MR200-A) ...........................................................................................26
5.1.1.1 Setting RS485 addresses for bus operation ..................................................26
ENGLISH
5.1.2 Ethernet Interface(ID ISC.MR200-E) ...........................................................................27
Technical Specifications
6.1
28
Approval ....................................................................................................................30
6.1.1 Europe (CE) ................................................................................................................30
6.1.2 USA (FCC)..................................................................................................................30
FEIG ELECTRONIC GmbH
Page 6 of 30
M40400-1de-ID-B.doc
OBID i-scan®
ID ISC.MR200
Safety Instructions / Warning - Read before start-up !
•
The device may only be used for the intended purpose designed by for the manufacturer.
•
The operation manual should be conveniently kept available at all times for each user.
•
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
•
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
•
Repairs may only be executed by the manufacturer.
•
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
•
Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
•
When working on devices the valid safety regulations must be observed.
FEIG ELECTRONIC GmbH
Page 7 of 30
M40400-1de-ID-B.doc
ENGLISH
Montage / Installation
OBID i-scan®
2.1
Montage / Installation
ID ISC.MR200
Features of the Reader Family ID ISC.MR200
Features
ENGLISH
The Reader is designed for reading passive data carriers, so-called „smart labels“, with an
operating frequency of 13.56 MHz.
The ID ISC.MR200 is suitable for any application in which medium-range read distances are
required. An additional external antenna is required which must be connected to the reader.
An anti-collision function allows simultaneous reading of multiple transponders.
The Reader electronics are housed in a rigid, powder-coated aluminum enclosure with an IP54
protection rating for use outdoors. It includes two digital inputs, two digital outputs and a relay
output.
The Reader has an asynchronous RS232 interface. Depending on the Reader model you can
choose from between an additional asynchronous interface (RS485 for the ID ISC.MR200-A) and
an Ethernet interface (ID ISC.MR200-E).
The interface on the ID ISC.MR200-A can be configured for operation on a data bus with RS485
interface. The Reader address can then be software assigned.
A DC voltage can be applied to the antenna output. This voltage powers the Dynamic Antenna
Tuner (ID ISC.DAT).
2.2
Available Reader models
The following Readers are currently available:
Reader model
Description
ID ISC.MR200-A
Asynchronous interfaces RS232 and RS485
ID ISC.MR200-E
Asynchronous interface RS232 and Ethernet Interface
Table 2-1: Reader models
FEIG ELECTRONIC GmbH
Page 8 of 30
M40400-1de-ID-B.doc
OBID i-scan®
2.3
Montage / Installation
ID ISC.MR200
Scope of delivery
Module type
Scope of delivery
ID ISC.MR200-A
1 x Reader ID ISC.MR200-A
3 x jumpers
2 x seal cap M16
2 x decorative cover, clip-on
2 x integrated cover stays
ID ISC.MR200-E
1 x Reader ID ISC.MR200-E
1 x jumper
4 x seal cap M12 - M25
1 x seal cap - reducer
2 x decorative cover, clip-on
2 x integrated cover stays
ENGLISH
The following components are included in the scope of delivery:
Table 2-2: Scope of delivery
FEIG ELECTRONIC GmbH
Page 9 of 30
M40400-1de-ID-B.doc
OBID i-scan®
ID ISC.MR200
Installation and Wiring
Installation
The Reader is designed for wall mount, including outdoors. Holes are provided in the housing for
wall attachment. The housing does not need to be opened for installation on a wall (see Fig. 1).
Antenna
Output
Input
Com
Power
110
200
182
60
ENGLISH
3.1
Montage / Installation
RFID by FEIG ELECTRONIC
Fig. 3-1: Housing ID ISC.MR200
Cable gland
Size
Clamping range
[mm]
Description
M 16
4.5 – 10
Antenna cable
M 16
4.5 – 10
Relay / Outputs
M 16
4.5 – 10
Inputs
M 12
3.5 – 7
Interface (serial)
M 12
3.5 – 7
Supply voltage
M 25
9 – 17
Ethernet Interface (model –E only)
Table 3-1: ID ISC.MR200 cable glands
FEIG ELECTRONIC GmbH
Page 10 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
3.1.1 Seal caps
The seal caps included in the scope of delivery can be used to close off unused cable fittings.
3.1.2 Cover stays
The two cover stays can be used to attach the cover to the housing. The cover stays are inserted
into the openings provided for this purpose.
Fig. 3-2: Cover stay
3.1.3 Decorative covers
The decorative covers are attached after installing the Reader.
The slot on the long side of the cover is used for disassembling the cover. Use a screwdriver to
remove the cover.
Fig. 3-3: Decorative cover
FEIG ELECTRONIC GmbH
Page 11 of 30
M40400-1de-ID-B.doc
ENGLISH
The reducing ring provided is intended for the network connection. The slotted reducer is placed
over the network cable and then fixed in place in the cable gland.
OBID i-scan®
3.2
Montage / Installation
ID ISC.MR200
Wiring terminals
X9
ENGLISH
J10
X2
J3 J2 J1
X8
X10
V5 V4 V3 V2 V1 J9 J8 J7 J6 J5 J4
K1
X4
2 1
X5
2 1
X3
2 1
X7
X6
2 1
2 1
X1
2 1
Fig. 3-4: Wiring terminals
Fig. 3-5: Maximum cable configuration (shown: ID ISC.MR200-E)
FEIG ELECTRONIC GmbH
Page 12 of 30
M40400-1de-ID-B.doc
OBID i-scan®
3.3
Montage / Installation
ID ISC.MR200
Antenna connection
An SMA socket is provided on the circuit board for connecting the external antenna.
The maximum tightening torque of the SMA sockets is 0.45 Nm.
Terminal
X2
ENGLISH
Caution:
Greater tightening torque will destroy the connector.
Description
External antenna connection
(input impedance 50Ω)
Table 3-2: Connecting the external antenna
Notes:
•
The input impedance of the antenna should be calibrated to a value of 50 Ω ± (3 Ω ∠ 3°).
•
The optimal operating Q of the antenna should be in a range of QO = 20...30. To
determine the operating Q, the antenna must be supplied with a 50Ω source, such as a
network analyzer or a frequency generator.
•
When connecting the antenna be sure that the permissible limits specified by national
code with respect to RF installations are not exceeded.
•
To meet national code with respect to RF installations, each antenna feed line must be
equipped with the supplied ∅ 28 mm x 20 mm EMC ferrite ring core. The antenna line
must be wrapped tightly around the EMC ferrite ring core at least 4 times. The distance
between the Reader connection and the ring core should be no greater than 20 cm (see
Fig. 3.2.-1).
max. 20cm
Fig. 3-6: Antenna cable with EMC ferrite ring core
FEIG ELECTRONIC GmbH
Page 13 of 30
M40400-1de-ID-B.doc
OBID i-scan®
3.4
Montage / Installation
ID ISC.MR200
Supply voltage
Connect the 12-24 VDC supply voltage to Terminal X1.
ENGLISH
The cable length between the power supply and the Reader module must not exceed 3 m.
Terminal
Abbreviation
Description
X1 / Pin 1
Vcc
Vcc – supply voltage
X1 / Pin 2
GND
Ground – supply voltage
Table 3-3: Supply voltage pin assignments
ID ISC.MR200
Vcc
GND
X3
Fig. 3-7: Connecting the supply voltage
Note:
•
Reversing the polarity of the supply voltage may destroy the unit.
FEIG ELECTRONIC GmbH
Page 14 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
Recommended power supplies :
The power supply should be a Safety Extra-Low Voltage (SELV) type with limited power. The
output power of the power supply should be at least 15 watts.
Output voltage
12 - 24 VDC
Output power
≥ 15 W
Ripple
< 150 mVpp
Switching frequency < 300 kHz
Table 3-4: Electrical specifications for external power supply
Model
Manufacturer
MPP15
CEAG AG / FRIWO Group
Von-Liebig-Straße 11
D- 48346 Ostbevern
Germany
Tel.: + 49 (0) 02532/ 81-158
www.friwo.de
AC adapter
MiniLine ML 30.100 PULS GmbH
MiniLine ML 30.102 Arabellastraße 15
D-81925 München
DIN rail mount
Germany
Tel.: +49 (0) 89 9278 0
www.puls-power.com
Table 3-5: Recommended power supplies
FEIG ELECTRONIC GmbH
Page 15 of 30
M40400-1de-ID-B.doc
ENGLISH
To make full use of the performance capability of the Reader module, a sufficiently regulated and
noise-free power supply (noise ripple = max. 150 mV) should be used. When using a switching
power supply be sure that the internal switching frequency of the power supply is less than 300
kHz.
OBID i-scan®
3.5
Montage / Installation
ID ISC.MR200
DC voltage on the RF antenna terminal X2
ENGLISH
Jumper J10 can be used to provide DC voltage on antenna terminal X2. This DC offset is used to
power the dynamic antenna tuner (ID DAT).
Note:
•
The DC voltage is intended only for power the ID ISC.DAT dynamic antenna tuner
•
Connecting other antennas to this DC voltage will destroy them
J10
X2
Fig. 3-8: Position Jumper J10
J10
1-2
2-3
DC voltage on
antenna terminal
No
(Default)
Yes
Table 3-6: Jumper J10 configuration
FEIG ELECTRONIC GmbH
Page 16 of 30
M40400-1de-ID-B.doc
OBID i-scan®
3.6
Montage / Installation
ID ISC.MR200
Inputs
The optocoupler inputs in Terminal X5 are galvanically isolated from the Reader electronics and
must therefore be externally supplied. The input LEDs for the optocouplers are switch internally
with a series resistor of 500 Ω. For supply voltages of greater than 10V the input current must be
limited to max. 20 mA by an additional external series resistor (see Table 3.4-1).
Terminal
Abbreviation
Description
IN1+
+ Input 1
IN1-
- Input 1
IN2+
+ Input 2
IN2-
- Input 2
Table 3-7: Optocoupler input pin assignments
Notes:
• The inputs are configured for a maximum input current of 24 V DC and an input current
of maximum 20 mA.
• Reversing the polarity or overloading the inputs will destroy them.
• The Reader supply voltage must not be used to drive the inputs, since otherwise
additionally induced noise may reduce the effective reading range.
ID ISC.MR200
X5
Rint
Rint
IN1+
IN1-
IN2+
IN2-
Rext
Rext
Uext.
Uext.
Fig. 3-9: Internal and possible external wiring of the optocoupler inputs
FEIG ELECTRONIC GmbH
Page 17 of 30
M40400-1de-ID-B.doc
ENGLISH
3.6.1 Optocoupler
OBID i-scan®
Montage / Installation
ID ISC.MR200
ENGLISH
Fehler! Verweisquelle konnte nicht gefunden werden. shows the required external series
resistances at various external voltages Uext.
External voltage Uext
Required external series
resistor Rext
5 V ... 10 V
---
11 V ... 15 V
270 Ω
16 V ... 20 V
560 Ω
21 V ... 24 V
820 Ω
Table 3-8: Required external series resistance Rext
FEIG ELECTRONIC GmbH
Page 18 of 30
M40400-1de-ID-B.doc
OBID i-scan®
3.7
Montage / Installation
ID ISC.MR200
Outputs
The transistor connections of the two optocoupler outputs, collector and emitter, are galvanically
isolated from the Reader electronics and brought out with no internal circuitry to Terminal X6. The
outputs must therefore be powered with an external power supply.
Terminal
Abbreviation
Description
O1-C
Collector – Output 1
O1-E
Emitter – Output 1
O2-C
Collector – Output 2
O2-E
Emitter – Output 2
Table 3-9: Optocoupler output pin configuration
Notes:
• The outputs are configured for max. 24 V DC / 30 mA.
• Reversing the polarity or overloading the outputs will destroy them.
• The outputs are intended for switching resistive loads only.
ID ISC.MR200
O1-C
X3
O1-E
O2-C
O2-E
Uext.
Uext.
Fig. 3-10:: Internal and possible external wiring of the optocoupler outputs
FEIG ELECTRONIC GmbH
Page 19 of 30
M40400-1de-ID-B.doc
ENGLISH
3.7.1 Optocouplers
OBID i-scan®
Montage / Installation
ID ISC.MR200
3.7.2 Relay
ENGLISH
A changeover relay is provided.
Terminal
Abbreviation
Description
COM
Working contact
NC
Normally closed
NO
Normally open
Table 3-10: Relay output pinouts
Notes:
• The relay outputs are configured for max. 24 V DC / 2 A.
• The relay outputs are intended for switching resistive loads only. If an inductive load is
used, the relay contacts must be protected by means of an external protection circuit.
ID ISC.MR200
X4
COM
NC
NO
Uext.
Fig. 3-11: Internal and possible external wiring of the relay output
FEIG ELECTRONIC GmbH
Page 20 of 30
M40400-1de-ID-B.doc
OBID i-scan®
3.8
Montage / Installation
ID ISC.MR200
Interfaces
3.8.1 RS232 interface
ENGLISH
The RS232 interface is connected at Terminal X6.
The transmission parameters are configured using software protocol.
Pin assignments X6 (RS232 interface):
Terminal
Abbreviation
Description
GND
RS232 – GND
RxD
RS232 - RxD
TxD
RS232 - TxD
Table 3-11: RS232 interface pin assignments
9-pol. DUB-D-Buchse
ID ISC.MR200
X6
GND
RxD
TxD
PC
X6 / 1
X6 / 2
X6 / 1
<−>
<−>
<−>
Pin 5
Pin 3
Pin 2
Fig. 3-12: Wiring example for connecting the RS232 interface
FEIG ELECTRONIC GmbH
Page 21 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
3.8.1.1 Wiring assignments
The RS485 interface is connected at Terminal X7.
ENGLISH
Pin assignments X7 (RS485 interface):
Terminal
Abbreviation
Description
GND
A-
RS485 – (A -)
B+
RS485 – (B +)
Y-
n.c.
Z+
n.c.
RS485 – (B +) RS485 – GND
Table 3-12: RS485 interface pin assignments
ID ISC.MR200
X7
RS485 - GND
RS485 - (A-)
RS485 - (B+)
nc
nc
Fig. 3-13: Wiring the RSR485 interface
FEIG ELECTRONIC GmbH
Page 22 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
3.8.2 Ethernet interface(ID ISC.MR200-E)
Cat 5 cable should be used for structured cabling. This ensures reliable operation at 10Mbps or
100Mbps.
Pin assignments X8 (network interface):
Terminal
Abbreviation
Description
TX+
Transmit Data +
TX-
Transmit Data -
RX+
Receive Data +
VETH+
n.c.
VETH+
n.c.
RX-
VETH-
n.c.
VETH-
n.c.
Receive Data -
Table 3-13: Ethernet interface pin assignments
FEIG ELECTRONIC GmbH
Page 23 of 30
M40400-1de-ID-B.doc
ENGLISH
The Reader has an integrated 10/100Tbase network interface with RJ-45 connection. Terminal X8
serves as the Ethernet port.
OBID i-scan®
ENGLISH
4.1
Montage / Installation
ID ISC.MR200
Operating and Display Elements
LED´s
Fehler! Verweisquelle konnte nicht gefunden werden. shows the configuration of the LED’s.
Abbreviation
LED V1 (green)
LED V2 (blue)
LED V3 (yellow
Description
"RUN-LED"
Indicates proper running of the internal Reader software
Flashing frequency approx. 1 Hz
Diagnostic 1: RF communication / EEPROM status
Short flashing indicates errorless communication with a
transponder on the RF interface
Flashes alternately with V1 after the reset following a software
update
Flashes alternately with V1 if an error in reading the
parameters occurred following a reset
Diagnostic 2: Host communication
Short flashing indicates a protocol is being sent to the host.
LED V4 (yellow)
Diagnostic 3: for future applications
LED V5 (red)
Diagnostic 4: Reader initializing / RF error
Comes on during Reader initializing following power-on or after
a reset.
Comes on when there is an error in the RF section of the
Reader.
The error type can be read via software using the Reader
Diagnostic command [0x6E].
Table 4-1: LED configuration
FEIG ELECTRONIC GmbH
Page 24 of 30
M40400-1de-ID-B.doc
OBID i-scan®
5.1
ID ISC.MR200
Startup
Port configuration
Both Reader ports can be used for communication. The Reader automatically detects which port is
being used for communication. The RS232 port is used as a service port and thus has higher
priority. If communication takes place on the RS232 port, the other port (RS485 for ID ISC.MR200A and network port for ID ISC.MR-200-E) is disabled for a time of 10 seconds. This lockout can be
cancelled by means of a reset.
Fehler! Verweisquelle konnte nicht gefunden werden. shows the standard configuration of the
RS232 port.
Baud rate
38400
Frame
8E1
Table 5-1: Standard configuration of the RS232 port
FEIG ELECTRONIC GmbH
Page 25 of 30
M40400-1de-ID-B.doc
ENGLISH
Montage / Installation
OBID i-scan®
Montage / Installation
ID ISC.MR200
5.1.1 RS485 (ID ISC.MR200-A)
ENGLISH
In the case of the RS485 interface, any necessary termination resistors can be enabled by
inserting jumpers J4, J5 and J6.
Jumper
In
Out
J4
Pull-Up on RS485 - B
without Pull-Up on RS485 - B
J5
Pull-Down on RS485 - A
without Pull-Down on RS485 – A
J6
Termination resistor
without termination resistor
RS485 - A ⇔ RS485 - B
RS485 - A ⇔ RS485 - B
Table 5-2: RS485 termination resistors
500 Ohm
J4
100 Ohm
J6
J5
500 Ohm
Fig. 5-1: RS485 port jumpers
5.1.1.1 Setting RS485 addresses for bus operation
The Reader allows you to assign the required bus address via software.
Addresses are assigned by the host computer. The software is used to assign addresses between
“0” and “254”.
Note:
Since all Readers are factory set with address 0, they must be connected and configured in
succession.
FEIG ELECTRONIC GmbH
Page 26 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
5.1.2 Ethernet Interface(ID ISC.MR200-E)
Note:
The Readers must be connected to the network and configured in succession.
Fehler! Verweisquelle konnte nicht gefunden werden. shows the standard configuration of the
network connection.
Network
Address
IP address
192.168.10.10
Subnet mask
255.255.255.0
Port
10001
Table 5-3: Standard configuration of the network connection
FEIG ELECTRONIC GmbH
Page 27 of 30
M40400-1de-ID-B.doc
ENGLISH
The prerequisite for using TCP/IP protocol is that each device on the network have a unique IP
address. All Readers have been assigned a factory default IP address.
OBID i-scan®
Montage / Installation
ID ISC.MR200
Technical Specifications
Mechanical Data
• Enclosure
Die-case aluminum, powder-coated,
ENGLISH
lockable hinged cover
• Dimensions ( W x H x D )
200 x 110 x 60 mm
• Weight
1.0 kg
• Enclosure rating
IP 54
• Color
RAL 7040 (similar to window grey)
Electrical Data
• Supply voltage
12 VDC to 24VDC ± 5 %
Noise Ripple : max. 150 mV
• Power consumption
max. 13 VA
• Operating frequency
13.56 MHz
• Transmitting power
1 W / 1.75W ± 1 dB
• Degree of modulation
20% ± 3% absolute
•
Antenna connection
1 x SMA socket (50Ω)
•
Outputs:
- 2 optocoupler
- 1 relay ( 1 x changeover)
24 V DC / 30 mA (galvanically isolated)
24 V DC / 2 A
• Inputs
– 2 optocoupler
max. 24 V DC/ 20 mA
• Interfaces
- ID ISC.MR200-A
- ID ISC.MR200-E
FEIG ELECTRONIC GmbH
RS232 and RS485
RS232 and Ethernet
Page 28 of 30
M40400-1de-ID-B.doc
OBID i-scan®
Montage / Installation
ID ISC.MR200
• EEPROM (for parameters)
10,000 write cycles
• FLASH
Software can be updated on interface
• Supported transponders
•
•
ISO15693 (I•Code SLI, Tag-it HFI, my-d,
STM LRI512)
I•Code MID and EPC-Transponder
• Address setting for interface
(ID ISC.MR200-A only)
• Optical indicators
- Software (up to 254 addresses)
5 LED´s for diagnosing the operating status
Ambient Conditions
• Temperature range
- Operating
- Storage
-20°C to +60°C
-25°C to +85°C
• Vibration
EN60068-2-6
10 Hz to 150 Hz : 0.075 mm / 1 g
• Shock
EN60068-2-27
Acceleration
: 30 g
Applicable Standards
• RF approval
- Europe
- USA
• EMC
EN 300 330
FCC 47 CFR Part 15
EN 301 489
• Safety
- Low Voltage
- Human Exposure
FEIG ELECTRONIC GmbH
EN 60950
EN 50364
Page 29 of 30
M40400-1de-ID-B.doc
ENGLISH
Functional Properties
OBID i-scan®
6.1
Montage / Installation
ID ISC.MR200
Approval
ENGLISH
6.1.1 Europe (CE)
When properly used, the RF system is in conformance with the essential requirements of Article 3
and the other relevant provisions of the R&TTE Directive 1995/5/EC of March 99.
Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489
6.1.2 USA (FCC)
FCC ID: PJMMR200
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device.
Warning: Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
FEIG ELECTRONIC GmbH
Page 30 of 30
M40400-1de-ID-B.doc

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Creator                         : FinePrint : Microsoft Word - M40400-1de-... (30 pages)
Create Date                     : 2005:02:02 10:25:33
Title                           : M40400-1de-ID-B.doc
Author                          : fiedler
Producer                        : Acrobat PDFWriter 5.0 für Windows NT
Modify Date                     : 2005:02:04 11:04:11+01:00
Page Count                      : 30
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJMMR200

Navigation menu