Feig Electronic MWDBP Motion Detector User Manual Manual MWD BP
Feig Electronic GmbH Motion Detector Manual MWD BP
User Manual
Instruction Manual Radar Motion Detector – MWD 07/21/2006 Manual MWD BP.doc BP Instruction Manual Radar Motion Detector MWD BP 2/13 General © Copyright 2006 by FEIG ELECTRONIC GmbH Lange Straße 4 35781 Weilburg Germany The indications made in these operating instructions may be altered without previous notice. With the edition of these instructions, all previous editions become void. Composition of the information given in this manual has been done to the best of our knowledge. FEIG ELECTRONIC does not guarantee the correctness of the details given in these instructions and may not be held liable for damages ensuing from incorrect installation. Since, despite of all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC does not give any guarantee promise for perfect function of the traffic detector in a cross surrounding. Copy or reproduction of these instructions, even if only partial, as well as translation into other languages is forbidden unless a written consent has been granted by FEIG ELECTRONIC. This also applies to the complete or partial storage of these operating instructions on modern input- and output media for further processing in data processing systems. Please read the operating- and safety instructions thoroughly before putting the motion detector into operation ! Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 3/13 Contents 1 Functional description____________________________________4 2 Installation _____________________________________________5 2.1 Place of installation _________________________________________________________ 5 2.2 Hints for planning and installation:____________________________________________ 5 3 Parameter Entry _________________________________________6 3.1 Open Parameter Entry ______________________________________________________ 6 3.2 Change Parameter__________________________________________________________ 6 3.3 Close Parameter Entry ______________________________________________________ 7 3.4 Show Service Parameter _____________________________________________________ 7 4 Standard Parameter List __________________________________8 5 Service Parameter List____________________________________9 6 Profiles ________________________________________________9 7 Notes _________________________________________________10 8 Connections ___________________________________________10 9 Technical data _________________________________________10 10 Type Approval _________________________________________11 10.1 Europe (CE) ______________________________________________________________ 11 10.2 USA (FCC) / Canada (IC)___________________________________________________ 12 11 Safety instructions ______________________________________13 Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 4/13 1 Functional description The MWD BP is a radar motion detector with direction identification, which has been especially designed for applications in the area of industrial gate- and barrier systems. In some cases, the operational parameters may also be adjusted with an infrared remote control. Motion detection is done according to the Doppler’s principle. The sensor sends out 24 GHz microwaves. These microwaves are reflected by objects in motion and thus their frequency changes. The sensor receives these altered frequencies and analyses them. Thus, each motion within the detection range is recorded, analyzed by a logic and transmitted to the gate- resp. barrier control by connecting potential-free change-over contacts. Range of application: Entry-/access recognition for the drive of industrial gate- and barrier systems Special features: • Insensitive to fluctuations of temperature and humidity • Distinction vehicles/persons • Suppression of cross traffic • Object tracking for slow objects • Reversible and cutoff direction logic • Adjustable sensitivity • Application specific parameter profiles • Two channel with individual parameter setting • Two potential-free relay contacts • Large supply voltage range - AC or DC • Adjustment of operational parameters by key buttons or infrared remote control and 7-segment display • Compact plastic housing • IP 65 housing • Easy and fast installation with mounting bracket Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 5/13 2 Installation 2.1 Place of installation The device is centrally mounted above the area to be monitored. Both wall- and ceiling mounting are possible. The maximum mounting height is 7m. 2.2 Hints for planning and installation: • The device has to be mounted vibrationless. • In order to avoid incorrect release, there must not be any objects in motion within the radiation field. • There must not be any fluorescent tubes within the radiation field of the detector. • It should be avoided that the radiation fields of two motion detectors overlap, since this may lead to incorrect releases. • Do not install behind objects, building coverings or elements. • If the motion detector is exposed to rain or snow, it should be adjusted to directional recognition. • If conductive floors are used and the radiation direction is almost vertical, incorrect releases may be caused by reflections. Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 6/13 3 Parameter Entry 3.1 Open Parameter Entry a) Remote Control MWD RC Symbol Key Keypress Description Action 1. i-Button short Channel 1: displayed address Channel 2: displayed address + 1 Actual device address is displayed with blinking digit and decimal point 2a. 1..4 value 1..4 short Direct confirmation of device address Display first parameter name short Select address value Increment or decrement value. Changed values doesn’t blink ! short Indirect confirmation of device address Display first parameter name Display Example Ñ1.Ò L. or Volume + 2b. Volume 3b. On/Off 2. L. b) Buttons on Motion Detector MWD BP The left button is functionally assigned to the On/Off-button on remote control MWD RC. Right button is equivalent to the Volume +- button KeyKey Description Action press 1. Right or Left short Channel 1: displayed address Channel 2: displayed address + 1 2. Right short Select address value 3. Left short Confirmation of device address 3.2 Actual device address is displayed with blinking digit and decimal point Increment or decrement value. Changed values doesn’t blink ! Display first parameter name Display Example Ñ1.Ò 2. L. Change Parameter Before changing parameter values you have to open the parameter entry as described above. a) Remote Control MWD RC Symbol Key Volume + Action Change parameter name short Return to display parameter value short (long) Change parameter value On/Off short Undo changes Display actual parameter value again (without decimal point) On/Off long Save new parameter value Decimal point expires after successful saving. short Return to display parameter name Display parameter name with character and decimal point. Volume On/Off Volume + 3. Volume 4a. Description short (long) 1. 2. Keypress (long: quick selection) (long: quick selection) Display parameter name with character and decimal point. Actual parameter value is displayed without decimal point. Display changed parameter value with blinking decimal point. Display Example d. P. 2.Ò 0.Ò or 4b. 5. Manual MWD BP.doc On/Off as 07/21/2006 d. FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP b) Buttons on Motion Detector MWD BP KeyKey press short 1. Right (long) Description 7/13 Action Change parameter name (long: quick selection) Display parameter name with character and decimal point. Actual parameter value is displayed without decimal point. 2. Left short Return to display actual parameter value 3. Right short (long) Change parameter value (long: quick selection) 4a. Left short Undo changes Display actual parameter value again (without decimal point). long Save new parameter value Decimal point expires after successful saving. short Return to display parameter name Display parameter name with character and decimal point. Display changed parameter value with blinking decimal point. Display Example d. 2.Ò or 4b. Left 5. 3.3 Left d. Close Parameter Entry a) Remote Control MWD RC Key Keypress Description Action On/Off long Close parameter entry from standard parameter menu service parameter menu display off Description Action Close parameter entry from standard parameter menu service parameter menu display off Symbol 1. b) Button on Motion Detector MWD BP KeyKey press 1. Left long Display Example Display Example c) automatic 60 s after last keypress on the remote control or directly on the motion detector parameter entry is closed automatically. 3.4 Show Service Parameter To display the Service Parameter you have first to open the parameter entry as described in chapter 3.1. Service Parameter names are displayed with blinking character and static decimal point. Menu navigation is conform to the navigation of standard parameter. a) Remote Control MWD RC 1. Symbol Key Keypress Description Action Display Example F+ or F- long Activate service parameter from standard parameter menu Display first service parameter name ÑA. b) Button on Motion Detector MWD BP The left button is functionally assigned to the On/Off-button on remote control MWD RC. The right button is equivalent to the Volume +- button. KeyButton Description Action press 1. Left and Right Manual MWD BP.doc long Activate service parameter from standard parameter menu as 07/21/2006 Display first service parameter name Display Example ÑA. FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 8/13 4 Standard Parameter List 7-Segment Display Parameter Value Range Name Parameter Name Parameter Definition Sensitivity Level L. 1..9, A..F 1 = low 7 = middle 9* F = high direction d. 0..2 0 = off 1 = approaching * 2 = departure 0 = off * 1 = low 3 = high 0 = off * 1 = low 3 = high 0 = off * 1 = low 3 = high 0 = off * 1 = low 3 = high 0 = off 1 = channel 1 * (for channel 1) 2 = channel 2 * (for channel 2) 3 = channel 1 OR channel 2 4 = channel 1 AND channel 2 human detection h. 0..3 vehicle detection u. 0..3 Cross traffic suppression C. 0..3 Object tracking O. 0..3 relay function r. 0..4 output on delay time t. 0..F 0 = 0s * 1..F = 0.2s .. 3.0s (value x 0.2s) output off delay Time T. 0..F 0 = 0s 1 = 0.2s 2 = 0.4s * 3..F = 0.6s .. 3.0s relay operating mode o. 0..1 0 = normally de-energized * 1 = normally energized P. 0..9 0 = parameter changed after profile setting (only displayed !) 1 = Profile No 1: initiate Factory Setting * 2..9 = Profile No. 2..9 Profiles (value x 0.2s) * factory setting Note: Resetting to factory values can be effected by parameter name “profile” with parameter value “1”. Alternatively press both keys while switching power supply on. Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 9/13 5 Service Parameter List 7-Segment Display Parameter Value Range Name Parameter A. device Address S. miscellaneous Settings i. firmware information Parameter Definition 1..9, b..d 1=1* d = 13 0..3 0 = all off ** 1 = key operation on, display relay output off 2 = only display relay status off ** 3 = key operation and display relay output on * (only odd address) show Firmware-Version on display: - manually, with „ “-Button for each character - automatically, with „i“-Button one character per second * factory setting ** Key operation is always available in the first 15 minutes after power on regardless of the parameter setting. If the display of the relay output is deactivated, only the decimal point is commonly used to show the relay status of both channels. 6 Profiles Profile No. Sensitivity Level Direction appr. appr. appr. appr. appr. appr. appr. appr. appr. Human Detection =2 =2 Vehicle Detection =2 =2 Cross Traffic Suppr. Object Tracking On delay Off delay 400 ms 400 ms 400 ms 400 ms 400 ms Relay Detection Channel Assignments (Logic) Working Principle Ch1 Ch2 Ch1 AP AP Factory Setting: Remarks additional parameter (e.g. device address =1) will be initialized too. Ch1 = Channel 1 AP = normally de-energized Manual MWD BP.doc Channel 2: Relay output off =2 =2 =2 =2 400 ms 400 ms 400 ms 400 ms Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 AP same as Factory Setting without initializing additional parameter AP Channel 1 : only persons Channel 2 : only vehicles AP Channel 1 : all objects Channel 2 : cross traffic suppression Ch2 = Channel 2 RP = normally energized as 07/21/2006 AP RP RP RP Profile No. 4, Profile No. 5, Profile No. 6, but with RP but with RP but with RP Channel 1 : all objects Channel 2 : slow motion object tracking appr. = approaching direction FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 10/13 7 Notes The MWD BP is a 2 channel device. While opening parameter entry first the odd address used to open channel 1 will displayed. The following even device address activates channel 2. In factory settings relay 1 with change over contacts is assigned to channel 1 (display „| .“) and relay 2 with normally open contact is assigned to channel 2 (display „| |.“). It is possible to change relay assignments via parameter entry. Only the odd device address of channel 1 can be changed. The address of channel 2 results from the following even address. Common parameter (e.g. firmware info, profiles...) can be displayed/changed with even or odd device address. 8 Connections X1 NC Com NO GND 24V NO Com Backside view, Contact status for power off 9 Technical data Dimensions Protective system 135x65x130mm (BxHxT) IP 65 Power supply Power consumption 12-27 V AC / 12-30 V DC typ. 1,0 W, max. 2,4 W Admissible working temperature Storing temperature Air moisture -20 °C .. +60 °C -30 °C .. +75 °C < 95 % not condensing Transmit frequency Output power (EIRP) typ. 24,125 GHz typ. 40 mW, max. 100 mW Output relay max. switching load min. switching load Maximum mounting height Manual MWD BP.doc 1 A / 30 V AC/DC (resistive load) 1 mA / 5 V DC Use external protective wiring for inductive load ! 7m as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 11/13 10 Type Approval 10.1 Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of article 3 and the other relevant provisions of the R&TTE guideline1999/5/EC dated March 99. Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 12/13 10.2 USA (FCC) / Canada (IC) FCC ID: PJMMWDBP IC: 6633A-MWDBP This device complies with part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH Instruction Manual Radar Motion Detector MWD BP 13/13 11 Safety instructions • This device shall only be used for the purpose intended by the manufacturer. • The operating instructions have to be handed out to each user and accessible at any time. • Improper changes and spare parts resp. special features which are not sold or recommended by the manufacturer of the device may cause fires, electric shock and injuries. Such measures therefore lead to nonliability of the manufacturer and no guarantee will be given. • For this device, the indemnity contract applies in the version valid at the time of purchase. We exclude liability for improper or wrong manual or automatic adjustment of parameters resp. improper use of the appliance. • Repair work should only be carried out by the manufacturer. • Connection, initiation, maintenance, measuring and adjustment of the motion detector should only be carried out by electrical engineers with accident prevention skills. • When handling appliances which get into contact with electric current, VDE-rules have to be observed - especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711, VDE 0860, VDE 0105 as well as the fire – and accident prevention standard VBG4. • Please switch off current supply prior to opening the device and make sure that it remains off. • If an indicator lamp goes out, this is not a proof that the device is without electricity and disconnected from power supply. All work that is carried out at the device as well as installation has to be carried out in conformance with the national electric regulations and the local rules. • The user has to make sure that the appliance is mounted and connected according to the technical rules of the country of installation as well as other regional regulations. This applies especially to cable dimensioning, protection, earthing, cutoff, disconnection, isolation supervision and excess current cut-out. • Low-voltage operation is not allowed at the relay outputs. • According to machine rule 89/392/EWG, appendix IV, the device may not be used as a safety component. In facilities with a high danger potential, additional safety devices are necessary ! • The hard gold alloy of the relay contacts is destroyed if switching currents of more than 100 mA are used. Relays with such pre-damaged contacts may only switch currents of more than 100 mA reliably! • If the place of operation is located in direct proximity to foil gates, suitable measures have to be taken to branch off the electrostatic charging of the gate foil. Manual MWD BP.doc as 07/21/2006 FEIG ELECTRONIC GmbH
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 13 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:2605dd2c-907c-4e85-b6a5-aae14c75a68d Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2006:08:22 16:20:24+02:00 Create Date : 2006:07:21 11:50:18+02:00 Metadata Date : 2006:08:22 16:20:24+02:00 Document ID : uuid:96542e7c-fcd2-4964-b3fb-ea719b804b2e Format : application/pdf Title : Manual MWD BP.doc Creator : Scheu Author : ScheuEXIF Metadata provided by EXIF.tools