Feig Electronic PRHD102 RFID Reader User Manual Installation ID ISC PRH D 102

Feig Electronic GmbH RFID Reader Installation ID ISC PRH D 102

User Manual

INSTALLATIONfinalpublic (B)2010-01-18PRH102 - Manual.docOBID i-scan®ID ISC.PRH102ID ISC.PRHD102
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 2 of 12 PRH102 - Manual.docNote© Copyright 2008-2009 byFEIG ELECTRONIC GmbHLange Strasse 4D-35781 Weilburg-WaldhausenTel.: +49 6471 3109-0http://www.feig.deWith the edition of this document, all previous editions become void. Indications made in this manual may bechanged without previous notice.Copying of this document, and giving it to others and the use or communication of the contents thereof are forbiddenwithout express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of thegrant of a patent or the registration of a utility model or design.Composition of the information in this document has been done to the best of our knowledge. FEIGELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in thismanual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONICGmbH does not give any guarantee promise for perfect function in cross environments and does not giveany guaranty for the functionality of the complete system which incorporates the subject of this document.FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designedwith components and testing methods for a level of reliability suitable for use in or in connection with surgicalimplants or as critical components in any life support systems whose failure to perform can reasonably beexpected to cause significant injury to a human. To avoid damage, injury, or death, the user or applicationdesigner must take reasonably prudent steps to protect against system failures.FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH doesnot convey any license under its patent rights nor the rights of others. OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 3 of 12 PRH102 - Manual.docContents1.  Safety Instructions / Warning - Read before start-up ! 42.  Performance Features of the Readers 52.1.  Performance features .........................................................................................................52.2.  Available Reader-Types......................................................................................................63.  Control and Display Elements 73.1.  Signal buzzer .......................................................................................................................73.2.  Scan - button .......................................................................................................................73.3.  LED .......................................................................................................................................84.  Assembly and Wiring 94.1.  Reader with asynchronous serial interface ID ISC.PRH102-B / ID ISC.PRHD102-B......94.2.  Reader with USB interface ID ISC.PRH102-USB / ID ISC.PRHD102-USB .......................95.  Technical Data 106.  Approvals 126.1.  Europe  (CE).......................................................................................................................126.2.  USA and Canada (FCC).....................................................................................................12
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 4 of 12 PRH102 - Manual.doc1. Safety Instructions / Warning - Read before start-up !• The device may only be used for the intended purpose designed by for the manufacturer.• When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separationof 20 cm between antenna and the human body must be maintained.• The operation manual should be conveniently kept available at all times for each user.• Unauthorized changes and the use o f spare parts and additional devices which have not beensold or recommended by the manufacturer ma y cause fire, electric shocks or injur ies. Suchunauthorized measures shall  exclude any liability by the manufacturer.• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are validfor the device. The manufacturer shall  not  be held legally responsible for inaccuracies, errors,or omissions in  the manual or automatically  set parameters for a device or   for an incorrectapplication of a device.• Repairs may only be executed by the manufacturer.• Installation, operation, and maintenance procedure s shou ld only be carried out  by qualifiedpersonnel.• Use of the device and its installation must be in accordance with national legal requirementsand local electrical codes .• When working on devices the valid safety regulations must be observed.• Special advice for carriers of cardiac pacemakers:Although this device doesn't exceed the valid limits for electromagnetic fields you should keepa minimum distance of 25 cm (10 inch) between the device and your cardiac pacemaker.
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 5 of 12 PRH102 - Manual.doc2. Performance Features of the Readers2.1. Performance featuresThe ID ISC.PRH102 and the ID ISC.PRHD102 have been developed for reading passive data car-riers, so-called „Smart Labels“, using operating frequencies either in the HF range or in the HF andUHF range. The readers have internal antennas and  will be delivered ready for  connection. Thedevice is designed as a handheld.An anti-collision function enables simultaneous reading of several transponders per second.The Reader electronic is fitted in a plastic housing with a protection class IP30.The Reader ID ISC.PRH(D)102-B have an asynchronous serial interface and the IDISC.PRH(D)102-USB have an USB interface. Depending on if HF or UHF transponder should be  detected the re ader comes with the  followingdifferent field areas as shown in the Fig.1 .Fig. 1: HF and UHF detection areas
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 6 of 12 PRH102 - Manual.doc2.2. Available Reader-TypesFollowing Reader-Types are available at present:Reader-Types DescriptionID ISC.PRH102-B HF Reader with serial interface with internal antenna.Powered via external 5 V DC/  power supply.ID ISC.PRH102-USB HF Reader with serial interface with internal antenna.Powered via a high powered USB port.ID ISC.PRHD102-B-EU Reader for Europe:HF and UHF Reader with serial interface with internal antenna.Powered via external 5 V DC/  power supply.ID ISC.PRHD102-USB-EU Reader for Europe:HF and UHF Reader with serial interface with internal antenna.Powered via a high powered USB port.ID ISC.PRHD102-B-FCC Reader for USA and Canada:HF and UHF Reader with serial interface with internal antenna.Powered via external 5 V DC/  power supply.ID ISC.PRHD102-USB-FCC Reader for USA and Canada:HF and UHF Reader with serial interface with internal antenna.Powered via a high powered USB port.Table 1: Reader-Types
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 7 of 12 PRH102 - Manual.doc3. Control and Display ElementsLEDScan-buttonFig. 2 Control and Display Elements3.1. Signal buzzerThe signal buzzer can be configured by the software.In the standard configuration the signal buzzer will be active if a Transponder is recognized.3.2. Scan - buttonThe switch of the reader can be configured by the software. In the standard con figuration the serial number of the Transponder is  read and is sent to the hostafter pressing the scan - button.
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 8 of 12 PRH102 - Manual.doc3.3. LEDThe Reader’s LED can be configured through software.Abbreviation DescriptionLED green "RUN "- Turns on when the Reader is ready.LED blue „TRANSPONDER“- Turns on when a Transponder is detected.LED red „WARNING“- Signals a warningLED orange „INITIALIZING “ and „WARNING“- Flashes during Reader initialization after power-up.Table 2: Standard configuration of the LEDs
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 9 of 12 PRH102 - Manual.doc4. Assembly and Wiring4.1. Reader with asynchronous serial interface ID ISC.PRH102-B / ID ISC.PRHD102-BThe communication and the power supply follows through the serial interface. The COM-port set-tings can be configured by the software.Note:If there is an USB/RS232 converter used on the PC/Notebook side, we recommend to in-crease the „Char Timeout Multiplier“ parameter in the COM-Port settings from „1“ to about„5“.4.2. Reader with USB interface ID ISC.PRH102-USB / ID ISC.PRHD102-USBThe power supply follows through the USB-interface (Bus-powered)The USB-interface must support a current of 500 mA (High Powered Interface)The data rate of the reader is reduced to 12 Mbit (USB high speed).The reader dispose of a fixed connected interfaces cable with standardized USB-connector. TheReader must only be connected to the USB-port of the PC. If the reader is used for the first time, it must be registered in the operating system of the computer.For this the instruction "M30100-xde-ID-B: Installation of the OBID USB driver" can be used
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 10 of 12 PRH102 - Manual.doc5. Technical DataMechanical Data• Housing ABS plastic (enclosed)• Dimensions ( W x H x D ) 230 x 100 x 80 mm  (9,06 x 3,94 x 3,15 inch)• Weight 320 g• Degree of Protection IP 30• Cable length approx. 2,5 m / 8,2 ft.• Color similar RAL 9002Electrical Data• Supply Voltage– ID ISC.PRH(D)102-B– ID ISC.PRH(D)102-USB5,0 V DC/  ± 0,2 V regulatedUSB - High Powered Interface• Current Draw max. 0,5 A• Power Consumption max. 2,5 VA• Operating Frequency– ID ISC.PRH102– ID ISC.PRHD10213,56 MHz13,56 MHz  and 860 ... 960 MHz• Transmitting Power– HF– UHF200 mW ± 2 dB100mW ± 2 dB• Antennas internal• Interface– ID ISC.PRH(D)102-B– ID ISC.PRH(D)102-USBSerialUSB (12 Mbit)
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 11 of 12 PRH102 - Manual.docFunctional Properties• Supported Transponders– HF– UHF• ISO15693, ISO18000-3-Mode1(EM HF ISO Chips, Fujitsu HF ISO Chips,KSW Sensor Chips, Infineon my-d, NXP I-Code, STM LRI ISO Chips, TI Tag-it)• EPC class 1 Gen 218000-6-C (optional)• Address setting for USB interface Device ID of the Readers• Indicators– optical– acoustical1 LED ( multicolor – red / green / blue)buzzerAmbient Conditions• Temperature range– Operation– Storage   0°C to +50°C   (32°F to 122°F)-20°C to +70°C   (-4°F to 158°F)• Humidity 5 – 95% non condensing• Fall Withstands multiple 5´/1,5 m drops to concreteApplicable Norms• Radio approval– Europe EN 300 330, EN 302 208• EMC EN 301 489• Safety- low voltage- Human ExposureEN 60950EN 50364
OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USBFEIG ELECTRONIC GmbH Page 12 of 12 PRH102 - Manual.doc6. Approvals6.1. Europe  (CE)When used according to regulation, this radio equipment conforms with the basic requirements ofArticle 3 and the other relevant provisions of the R&TTE Guideline 1999/5/EC dated March 99.Equipment Classification according to ETSI EN 301 489: Class 26.2. USA and Canada (FCC)FCC ID PJMPRH102 / FCC ID PJMPRHD102This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that maycause undesired operation.NOTICE:Changes or modifications made to this equipment not expressly approved byFEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-sonable protection against harmful interference in a residential installation. This equip-ment generates, uses and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to radio com-munications. However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio or television recep-tion, which can be determined by turning the equipment off and on, the user is encour-aged to try to correct the interference by one or more of the following measures:-- Reorient or relocate the receiving antenna.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit different from that to    which the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help.