Feig Electronic PRHD102 RFID Reader User Manual Installation ID ISC PRH D 102
Feig Electronic GmbH RFID Reader Installation ID ISC PRH D 102
User Manual
OBID i-scan ® INSTALLATION ID ISC.PRH102 ID ISC.PRHD102 final public (B) 2010-01-18 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB Note © Copyright 2008-2009 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH. FEIG ELECTRONIC GmbH Page 2 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB Contents 1. Safety Instructions / Warning - Read before start-up ! 2. Performance Features of the Readers 2.1. Performance features .........................................................................................................5 2.2. Available Reader-Types......................................................................................................6 3. Control and Display Elements 3.1. Signal buzzer .......................................................................................................................7 3.2. Scan - button .......................................................................................................................7 3.3. LED .......................................................................................................................................8 4. Assembly and Wiring 4.1. Reader with asynchronous serial interface ID ISC.PRH102-B / ID ISC.PRHD102-B......9 4.2. Reader with USB interface ID ISC.PRH102-USB / ID ISC.PRHD102-USB .......................9 5. Technical Data 10 6. Approvals 12 6.1. Europe (CE).......................................................................................................................12 6.2. USA and Canada (FCC).....................................................................................................12 FEIG ELECTRONIC GmbH Page 3 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 1. Safety Instructions / Warning - Read before start-up ! • The device may only be used for the intended purpose designed by for the manufacturer. • When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation of 20 cm between antenna and the human body must be maintained. • The operation manual should be conveniently kept available at all times for each user. • Unauthorized changes and the use o f spare parts and additional devices which have not been sold or recommended by the manufacturer ma y cause fire, electric shocks or injur ies. Such unauthorized measures shall exclude any liability by the manufacturer. • The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. • Repairs may only be executed by the manufacturer. • Installation, operation, and maintenance procedure s shou ld only be carried out personnel. • Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . • When working on devices the valid safety regulations must be observed. • Special advice for carriers of cardiac pacemakers: Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm (10 inch) between the device and your cardiac pacemaker. FEIG ELECTRONIC GmbH Page 4 of 12 by qualified PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 2. Performance Features of the Readers 2.1. Performance features The ID ISC.PRH102 and the ID ISC.PRHD102 have been developed for reading passive data carriers, so-called „Smart Labels“, using operating frequencies either in the HF range or in the HF and UHF range. The readers have internal antennas and will be delivered ready for connection. The device is designed as a handheld. An anti-collision function enables simultaneous reading of several transponders per second. The Reader electronic is fitted in a plastic housing with a protection class IP30. The Reader ID ISC.PRH(D)102-B have an asynchronous serial interface and the ID ISC.PRH(D)102-USB have an USB interface. Depending on if HF or UHF transponder should be different field areas as shown in the Fig.1 . detected the re ader comes with the following Fig. 1: HF and UHF detection areas FEIG ELECTRONIC GmbH Page 5 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 2.2. Available Reader-Types Following Reader-Types are available at present: Reader-Types Description ID ISC.PRH102-B HF Reader with serial interface with internal antenna. power supply. Powered via external 5 V DC/ ID ISC.PRH102-USB HF Reader with serial interface with internal antenna. Powered via a high powered USB port. ID ISC.PRHD102-B-EU Reader for Europe: HF and UHF Reader with serial interface with internal antenna. power supply. Powered via external 5 V DC/ ID ISC.PRHD102-USB-EU Reader for Europe: HF and UHF Reader with serial interface with internal antenna. Powered via a high powered USB port. ID ISC.PRHD102-B-FCC Reader for USA and Canada: HF and UHF Reader with serial interface with internal antenna. power supply. Powered via external 5 V DC/ ID ISC.PRHD102-USB-FCC Reader for USA and Canada: HF and UHF Reader with serial interface with internal antenna. Powered via a high powered USB port. Table 1: Reader-Types FEIG ELECTRONIC GmbH Page 6 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 3. Control and Display Elements LED Scan-button Fig. 2 Control and Display Elements 3.1. Signal buzzer The signal buzzer can be configured by the software. In the standard configuration the signal buzzer will be active if a Transponder is recognized. 3.2. Scan - button The switch of the reader can be configured by the software. In the standard con figuration the serial number of the Transponder is read and is sent to the host after pressing the scan - button. FEIG ELECTRONIC GmbH Page 7 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 3.3. LED The Reader’s LED can be configured through software. Abbreviation LED green Description "RUN " - Turns on when the Reader is ready. LED blue „TRANSPONDER“ - Turns on when a Transponder is detected. LED red „WARNING“ - Signals a warning LED orange „INITIALIZING “ and „WARNING“ - Flashes during Reader initialization after power-up. Table 2: Standard configuration of the LEDs FEIG ELECTRONIC GmbH Page 8 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 4. Assembly and Wiring 4.1. Reader with asynchronous serial interface ID ISC.PRH102-B / ID ISC.PRHD102-B The communication and the power supply follows through the serial interface. The COM-port settings can be configured by the software. Note: If there is an USB/RS232 converter used on the PC/Notebook side, we recommend to increase the „Char Timeout Multiplier“ parameter in the COM-Port settings from „1“ to about „5“. 4.2. Reader with USB interface ID ISC.PRH102-USB / ID ISC.PRHD102-USB The power supply follows through the USB-interface (Bus-powered) The USB-interface must support a current of 500 mA (High Powered Interface) The data rate of the reader is reduced to 12 Mbit (USB high speed). The reader dispose of a fixed connected interfaces cable with standardized USB-connector. The Reader must only be connected to the USB-port of the PC. If the reader is used for the first time, it must be registered in the operating system of the computer. For this the instruction "M30100-xde-ID-B: Installation of the OBID USB driver" can be used FEIG ELECTRONIC GmbH Page 9 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 5. Technical Data Mechanical Data • Housing ABS plastic (enclosed) • Dimensions ( W x H x D ) 230 x 100 x 80 mm (9,06 x 3,94 x 3,15 inch) • Weight 320 g • Degree of Protection IP 30 • Cable length approx. 2,5 m / 8,2 ft. • Color similar RAL 9002 Electrical Data • Supply Voltage – ID ISC.PRH(D)102-B – ID ISC.PRH(D)102-USB 5,0 V DC/ ± 0,2 V regulated USB - High Powered Interface • Current Draw max. 0,5 A • Power Consumption max. 2,5 VA • Operating Frequency – ID ISC.PRH102 – ID ISC.PRHD102 • Transmitting Power – HF – UHF • • Antennas Interface – ID ISC.PRH(D)102-B – ID ISC.PRH(D)102-USB FEIG ELECTRONIC GmbH 13,56 MHz 13,56 MHz and 860 ... 960 MHz 200 mW ± 2 dB 100mW ± 2 dB internal Serial USB (12 Mbit) Page 10 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB Functional Properties • Supported Transponders – HF – UHF • Address setting for USB interface • Indicators – optical – acoustical • ISO15693, ISO18000-3-Mode1 (EM HF ISO Chips, Fujitsu HF ISO Chips, KSW Sensor Chips, Infineon my-d, NXP ICode, STM LRI ISO Chips, TI Tag-it) • EPC class 1 Gen 2 18000-6-C (optional) Device ID of the Readers 1 LED ( multicolor – red / green / blue) buzzer Ambient Conditions • Temperature range – Operation – Storage 0°C to +50°C (32°F to 122°F) -20°C to +70°C (-4°F to 158°F) • Humidity 5 – 95% non condensing • Fall Withstands multiple 5´/1,5 m drops to concrete Applicable Norms • Radio approval – Europe • EMC • Safety - low voltage - Human Exposure FEIG ELECTRONIC GmbH EN 300 330, EN 302 208 EN 301 489 EN 60950 EN 50364 Page 11 of 12 PRH102 - Manual.doc OBID i-scan ® Installation ID ISC.PRH(D)102-B / -USB 6. Approvals 6.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/5/EC dated March 99. Equipment Classification according to ETSI EN 301 489: Class 2 6.2. USA and Canada (FCC) FCC ID PJMPRH102 / FCC ID PJMPRHD102 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE: Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FEIG ELECTRONIC GmbH Page 12 of 12 PRH102 - Manual.doc
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Fiedler Company : FEIG ELECTRONIC GmbH Create Date : 2010:01:18 14:44:01+01:00 Modify Date : 2010:04:27 11:05:32+02:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : Acrobat PDFMaker 6.0 für Word Metadata Date : 2010:04:27 11:05:32+02:00 Document ID : uuid:b0aa8a8d-f50d-49c7-9415-f5a8a1c9baf9 Instance ID : uuid:60fd9342-75df-4f53-b481-fdb0d34913f9 Format : application/pdf Title : Installation ID ISC.PRH(D)102 Creator : Fiedler Page Count : 12EXIF Metadata provided by EXIF.tools