Feig Electronic RW02 Inductive Reader User Manual RW02 Manual
Feig Electronic GmbH Inductive Reader RW02 Manual
Users Manual
OBID ® Installation ID RW02.ABC ID RW02.ABC-A (RS232 Interface) ID RW02.ABC-B (RS485 Interface) ENGLISH (english) FEIG ELECTRONIC GmbH Page 1 of 18 OBID ® Installation ID RW02.ABC Note ENGLISH Copyright 1999 - 2002 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful advises. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID® is registered trademark of FEIG ELECTRONIC GmbH. General information's regarding this document The sign "F" indicates extensions or changes of this manual compared with the former issue. Page 2 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 1. Safety instructions 2. Installation 3. 4. 2.1 Installation on flush-mounting box ...........................................................................6 2.2 Installation with surface frame ID APR-A .................................................................. 7 Reader-connection 3.1 (F) Jumper and Switches .......................................................................................... 9 3.2 Power supply.............................................................................................................10 3.3 Relay .......................................................................................................................... 10 3.4 Digital inputs (IN1 / IN2)............................................................................................ 10 3.5 RS232 Interface (ID RW02.ABC-A) ...........................................................................10 3.6 (F) RS485 Interface (ID RW02.ABC-B) .................................................................... 11 3.7 (F) Data-/Clock interface.......................................................................................... 12 Operation 4.1 5. 6. 13 Address setting (Bus mode with RS485 interface).................................................13 (F) Technical data 14 5.1 Approval .................................................................................................................... 15 5.2 USA (FCC).................................................................................................................. 15 5.3 Dimensions for concealed installation .................................................................... 16 5.4 Dimensions for surface installation with ID APR-A ................................................ 17 System delivery contents: 6.1 18 OptionalAccessories ...............................................................................................18 FEIG ELECTRONIC GmbH Page 3 of 18 ENGLISH Content OBID ® Installation ID RW02.ABC ENGLISH 1. Safety instructions • The device has to be used only for the purpose designed by the manufacturer. • The operation manual has to be stored available at any time and has to be handed over to each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such measures will lead to exclusion of any liability by the manufacturer. • The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer is not legally responsible for incorrect, unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device. • Repairs can only be executed by the manufacturer. • Installation-, operation- and maintenance procedures should only be carried out by qualifiedpersonnel. • Before opening the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. CAUTION! The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being without voltage! • Works at the device and its installation have to be executed according to the national legal requirements and local prescriptions. • When working on devices the valid safety regulations must be observed. Page 4 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 2. Installation NOTES: • The Reader must not be installed directly upon conductive materials as e.g. metal sur- faces, metal grids (reinforcements) or metallized surfaces, as these surfaces reduce the detection range of the Reader. The distance between the Reader and such surfaces should be min. 3 cm. If an installation to a metal surface becomes necessary, the surface frame ID APR-A can be employed in order to keep the minimal distance. • The distance between two Readers of the same type should not fall below 30 cm. • Before any installation the intended position of the Reader should be tested for its suit- ability. • The opening (A) in the casing (see Fig 1) has to be installed downwards! Fig 1: mounting direction (A) downwards FEIG ELECTRONIC GmbH Page 5 of 18 ENGLISH The Reader has been designed for wall installation on 60 mm flush-mounting box. For surface installation, the bottom part of the casing can be substituted by the surface frame ID APR-A, which is available as an attachment. OBID ® Installation ID RW02.ABC 2.1 Installation on flush-mounting box ENGLISH 1. Select installation place: The installation should be executed always on a surface as even as possible. 2. Connection: see chapter Reader-connection 3. Operation: • snap connection board into bottom part of casing (see Fig 2). • Put the top of the casing onto its bottom part. The pin board of the Reader electronic has to be inserted carefully into the socket board X3! • see chapter Installation 4. Wall installation: The wall installation should be executed only after a control of all functions. • Remove top of the casing from its bottom part again. • Screw bottom part of casing with snapped-in connection board to selected surface. • Put top of the casing again onto its bottom part. Insert the pin board of the Reader electronic carefully in the socket board X3! • Screw top of casing to bottom part by using thread cutting screw 3,2 x 25 mm. • Attach adhesive label to clean and non-greasy casing. X3 (1) Fig 2: Rear view with snapped-in connection board (1) Page 6 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 2.2 Installation with surface frame ID APR-A • The installation should be executed always on a surface as even as possible. • Make openings into the bottom part of the casing for lead-in wire, eventually attach twisting sleeve and pull wire into the casing. • Screw bottom part of casing to surface. 2. Connection: see chapter Reader-connection 3. Close casing: • Put the connection board (1) out of the bottom part of the concealed casing and snap it into the bottom part of casing according to Fig 3 with the connectors in downward direction. In order to do this, press the notches slightly apart with your fingers. • Put top of the casing onto its bottom part. Insert the pin board of the Reader electronic carefully into the socket board X3!! • Screw top of casing to bottom part by using thread cutting screw 3,2 x 25 mm. 4. Operation: see chapter Reader-connection 5. Adhesive label: Attach label to clean and non-greasy casing +/~ -/~ R COM NO GND R/A T/B CLK DAT IN1 IN2 (1) Fig 3: Surface installation (LED top left) Open surface casing with snapped-in connection board (1) FEIG ELECTRONIC GmbH Page 7 of 18 ENGLISH 1. Wall installation: OBID ® Installation ID RW02.ABC 3. Reader-connection The connection of the Reader is executed via the connection board. (see: Fig 4) which is snapped into the bottom part of the casing. ENGLISH CLK DAT IN1 IN2 X1 X3 X2 +/~ -/~ CLS COM NO GND R/A T/B Fig 4: Connection board connector board name +/~ -/~ CLS X2 ID RW02.ABC-A ID RW02.ABC-B power supply 12 - 24 AC / DC data-/clock interface – cls COM NO GND R/A X1 function relay internal GND T/B CLK RS232 - RxD RS485 - A RS232 - TxD RS485 - B data-/clock interface – clock DAT IN1 data-/clock interface – data digital input 1 (IN1) IN2 digital input 2 (IN1) Table 1: connection plan Page 8 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 3.1 (F) Jumper and Switches Fig 5 shows the position of the jumpers and switches on the printed circuit board of the ID RW02.ABC. The jumpers and switches are only accessible at opened device. X7 J2 ENGLISH J1 1 2 3 4 5 6 7 8 ON OFF S1 X1 X2 X3 X4 1 2 3 Fig 5: Jumper and switsches S1: DIP-switch to configure the Reader address. X1: Terminal for sticking up the connection board. X2 / X3 / X4: Jumper for termination resistors of the RS485 interface (only ID RW02.ABC-B). X7: Interface for firmware update. J1 / J2: Jumper for firmware update. FEIG ELECTRONIC GmbH Page 9 of 18 OBID ® Installation ID RW02.ABC 3.2 Power supply ENGLISH The power supply is effected via the connectors [+ / ~] and [- / ~]. The device may be supplied either with 12 - 24 V AC or DC. In case of DC supply, the polarity may be chosen freely. NOTE: The lead-in wire should not be laid directly parallel to other power supply- and low voltage wires. 3.3 Relay The device is equipped with an relay (normally open contact). The connection is executed via the connectors [NO] and [COM]. 3.4 Digital inputs (IN1 / IN2) The digital inputs [IN1] and [IN2] can only be connected to internal GND (terminal [GND]) according to Fig 6. Any connection to external voltage might damage the unit! IN1 IN2 GND Fig 6: connection of the digital inputs 3.5 RS232 Interface (ID RW02.ABC-A) Readers with RS232 interface have to be connected to the host according to Fig 7. Host RxD TxD GND R/A T/B GND ID RW02 Fig 7: connection of the RS232-interface Page 10 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 3.6 (F) RS485 Interface (ID RW02.ABC-B) To operate the bus, you need a host computer with a terminating resistor and active termination. A twisted paired or stranded wire is recommended. Host ID RW02 ID RW02 ID RW02 (with active termination) X2 T/B X2 X2 R/A R/A T/B R/A T/B without termination with termination resistor Fig 8: data bus with RS485 interface If no host computer with active termination is available, a active termination can be implemented as an alternative at maximum one Reader. The Jumpers X3 and X4 are available to this. X2 X2 X2 X3 X3 X3 X4 1 2 3 X4 X4 1 2 3 without termination (default) 1 2 3 with termination resistor active termination and termination resistor Fig 9: Jumper positions of the RS485 interface X4 +5V 1 kΩ T/B X2 100Ω R/A 1 kΩ X3 GND Fig 10: intern construction of the RS485 interface FEIG ELECTRONIC GmbH Page 11 of 18 ENGLISH With RS485 data buses, it can be necessary to use terminating resistors. For each installation, checks should be made as to whether it is necessary to use terminating resistors, because this e.g. is dependent on line lengths, bus structure, powering of the Readers and the employed host computer. Generally, a terminating resistor is only required at the end of the bus, i.e. on the last unit. In order to do this, the Jumper needs to be pit on X2 terminals 1 and 2 (see Fig 8 and Fig 5). OBID ® Installation ID RW02.ABC 3.7 (F) Data-/Clock interface The connection of the data-/clock interface is executed according to Fig 11. If no CLS signal is required on host, this connection can be abandon. Host ENGLISH CLOCK DATA CLS GND CLK DAT CLS GND ID RW02 Fig 11: connection of the data-/clock interface Page 12 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 4. Operation For Readers with RS232 interfaces usually no address setting is necessary. In case of units with RS485 interface, the unit address can be set either via the DIP-switch on the opened unit (see Fig 5), or via the host. Bus mode with up to 16 Readers: The setting of the individual addresses is executed via the DIP-switches S1, DIP1 - DIP 4 according to the table seen below (DIP5 - DIP8 are unused). Thus, each Reader is being provided with an individual address. Address 10 11 12 13 14 15 DIP 1 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DIP 2 OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON DIP 3 OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON DIP 4 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON Bus mode with 16 - 32 Readers: The setting of addresses is executed by the host-PC (host). NOTE: Due to the default value 0 of each Reader, they have to be connected and configurated one after another. FEIG ELECTRONIC GmbH Page 13 of 18 ENGLISH 4.1 Address setting (Bus mode with RS485 interface) OBID ® Installation ID RW02.ABC 5. (F) Technical data casing Plastic material ASA ENGLISH colour bottom part of casing: similar to RAL 9002 (greyish white) top of casing: similar to RAL 7043 (traffic grey) weight approx. 120 g protective system IP 54 power supply 12 - 24 V AC/DC power consumption max. 2,5 W temperature range -25°C to 70°C relative air humidity 95 % (non-condensing) antenna integrated data transmission with transponder 125 kHz for transponder • ID CTx.A • ID DTx.B • ID DTx.C signal transmitter 1 x bicolor-LED (red, green, orange) 1 x buzzer relay 1 x normally open capacity of contacts: 24 V AC/DC 1,5 A digital inputs 2 x configurable length of lead-in wire max. 3 m interfaces asynchrony (bi-directional) 2400 to 38400 Baud • RS232 (ID RW02.ABC-A) length of lead-in wire max. 10 m • RS485 (ID RW02.ABC-B) max. 32 units on each data bus data / clock (unidirectional) TTL length of lead-in wire max. 3 m • Magnetic Stripe Emulation, track 1 (7 Bit), track 2+3 (5 Bit) • Wiegand Emulation DIP-switch 8-channel EEPROM 10.000 writing cycles Default values (factory alined): asynchronous interface: IN1 IN2 LED-operation control Page 14 of 18 9600 Baud, 8 data- 1 stopbit, even parity activates LED red and relay aktivates LED green and buzzer orange FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC 5.1 Approval ENGLISH When properly used this radio equipment conforms to the basic requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/E6 of March 99. 5.2 USA (FCC) FCC ID: PJMRW02 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device is labeled with an FCC ID number. If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used: This device contains transmitter module FCC ID PJMRW02 FEIG ELECTRONIC GmbH Page 15 of 18 OBID ® Installation ID RW02.ABC ENGLISH 5.3 Dimensions for concealed installation Fig 12: Dimensions of concealed casing (A) = below Page 16 of 18 FEIG ELECTRONIC GmbH OBID ® Installation ID RW02.ABC ENGLISH 5.4 Dimensions for surface installation with ID APR-A Fig 13: Dimensions for installation with surface frame ID APR-A (A) = below FEIG ELECTRONIC GmbH Page 17 of 18 OBID ® Installation ID RW02.ABC 6. System delivery contents: 1 x bottom part of casing (concealed casing) 1 x top of casing with Reader electronic ENGLISH 1 x connection board 1 x adhesive label 1 x thread cutting screw 3,2 x 25 mm (for connecting parts of casing) 2 x thread cutting screws 3,2 x 15 mm (for wall installation) 1 x Installation instructions 6.1 Optional Accessories bottom part of casing for surface installation ID APR-A Order-No.: 1144.001.00 adhesive front label ID AKL.02 Page 18 of 18 Order-No.: 1424.000.00 FEIG ELECTRONIC GmbH
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Creator : FinePrint Create Date : 2003:05:19 10:33:04 Title : RW02-Manual.doc Author : schuessl Producer : Acrobat PDFWriter 5.0 für Windows NT Modify Date : 2003:12:09 12:35:12+01:00 Page Count : 18EXIF Metadata provided by EXIF.tools