Feig Electronic TSTPDFSAS Wireless Safety System for industrial doors - Stationary Unit User Manual PD FSAS Eng 150409
Feig Electronic GmbH Wireless Safety System for industrial doors - Stationary Unit PD FSAS Eng 150409
User Manual
TST PD_FSAS 2. Connection image inside with: Multiturn Absolute Encoder w/ integrated Wireless Safety System for industrial doors – Stationary Unit interface cable coaxial cable with MCX connector Mounting and Startup manual ATTENTION The content of the door controller manual and particularly the safety instructions must get note! reset pins X3- 2 and X3- 1 JST connector 8-pole Connector: battery with connector (see 2.1) M12, 8- polig, cable 0,4m 4x2x0.25 2.1 Encoder: battery change: Attention TST PDFSAS-0.0-A Disconnecting the battery effects clearing of position values from the encoder! After reconnecting the battery a RESET must be done. Do not short or charge the battery. Do not store or operate the system above the specified temperature range. Connecting the encoder with switched on supply voltage is not allowed. Antenna: TST FSAS- 0.1-A- circuit board- Antenna with 0.9m long coaxial cable To do an Reset you must make an short cut between the Reset pins X3-2 and X3-1 for a short moment 3. Mounting of encoder: 1. Pin connections: weiß/white braun/brown TST PDFSAS grün/green gelb/ yellow grau/grey rosa/pink blau/blue rot /red GND +24V RS485 B RS485 A (not used) safety edge n o. (safety edge 2 optional) breakaway 34 31 36 35 Si2 screw M3 for magnet holder fixing Controller FU3P 15.5 mm / 0.63 inch ... 17.5 mm / 0.69 inch 24.5 mm / 0.965 inch ... 26.5 mm / 1.04 inch mounting plate engine shaft or gear box shaft D = 12.0 mm + 0 mm / -0.1 mm D = 0.49 inch + 0 inch / -0.004 inch Remarks: - For connection shielded cables with M12 A-encoded plug are recommended. The shield has to be connected to earth ground only on the controller side. - The housing of the plug is not allowed to be connected to earth ground. - Not used wires must be isolated inside of FU3P magnet holder with magnet The assembling tolerance from shaft center to sensor center is maximum +/-1 mm (+/- 0.039 inch). Torque for M3 screw / magnet holder fixing : maximum 0.4 Nm FEIG ELECTRONIC GmbH Lange Str. 4 D-35781 Weilburg, Germany Tel.: +49 (0) 6471 / 3109-0 Fax: +49 (0) 6471 / 3109-99 www.feig.de Email: info@feig.de PD_FSAS_Eng_150409.Doc 4. Mounting of the stationary Antenna: 6. Technical Data: Side view Connection data: Supply voltage +24 V +/-10%, typical 50 mA. Serial bidirectional Interface RS485 / 19,2k Baud Digital outputs: Three configurable outputs with the following standard setting: Output 1 and 2: Safety output (N.O.) with 8.2kΩ terminal resistor and testing of terminal resistor. Output 3: Breakaway output (N.C. contact at 24V with 560Ω limiting resistor) Connecting to A-encoded M12 plug with 35cm long cable. Front view Antenna Antenna The max. allowed Length of the customer mounted cable is 50m Radio : Temperature range: Mobile unit Mobile unit Figure: Mounting of Antenna on door 5. Stationary Antenna + aluminum mounting bracket: 45 12 0 aluminum mounting bracket 60 7,6 44 24,5 10 39 drill holes 15 4,2 84 Figure: Stationary Antenna + aluminum mounting bracket Operating range 2400 to 2483.5MHz 40 channels, Rated output power 0dBm Operating range –40 to +70°C, Storage range –40 to +70°C (recommended +20°C) Protection class: IP65 Max. tolerable speed: 6000 U/min Resolution: 13 Bit / turn (8192 Increments / turn) Counter of turns: 15 Bit Weight: Without cable but with magnet holder 220g Lifetime of battery: typical 10 years Dimensions (L x B x H): Encoder 92 x 69.5 x 24mm Antenna board 84 x 39 x 7.6mm (Antenna height 26mm) 7. FCC Statements: Notice: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice: Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC may void the FCC authorization to operate this equipment. Notice: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio / TV technician for help FEIG ELECTRONIC GmbH Lange Str. 4 D-35781 Weilburg, Germany Tel.: +49 (0) 6471 / 3109-0 Fax: +49 (0) 6471 / 3109-99 www.feig.de Email: info@feig.de PD_FSAS_Eng_150409.Doc
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:3e57cf26-ec72-4521-894f-e2be66bd5bec Producer : Acrobat Distiller 6.0.1 (Windows) Create Date : 2009:04:15 11:05:22+02:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2009:04:15 11:05:22+02:00 Document ID : uuid:476cfe19-adf5-414e-9ac2-ce8ec96152a6 Format : application/pdf Title : Microsoft Word - PD_FSAS_Eng_150409.doc Creator : heinze Author : heinzeEXIF Metadata provided by EXIF.tools