Feig Electronic TSTPDFSAS Wireless Safety System for industrial doors - Stationary Unit User Manual PD FSAS Eng 150409

Feig Electronic GmbH Wireless Safety System for industrial doors - Stationary Unit PD FSAS Eng 150409

User Manual

Download: Feig Electronic TSTPDFSAS Wireless Safety System for industrial doors - Stationary Unit User Manual PD FSAS Eng 150409
Mirror Download [FCC.gov]Feig Electronic TSTPDFSAS Wireless Safety System for industrial doors - Stationary Unit User Manual PD FSAS Eng 150409
Document ID1104063
Application IDQkypSyz38ZkK4zw5iPm7oA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize17.22kB (215191 bits)
Date Submitted2009-04-30 00:00:00
Date Available2009-04-30 00:00:00
Creation Date2009-04-15 11:05:22
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2009-04-15 11:05:22
Document TitleMicrosoft Word - PD_FSAS_Eng_150409.doc
Document CreatorPScript5.dll Version 5.2
Document Author: heinze

TST PD_FSAS
2. Connection image inside with:
Multiturn Absolute Encoder w/ integrated
Wireless Safety System for industrial doors
– Stationary Unit
interface cable
coaxial cable with
MCX connector
Mounting and Startup manual
ATTENTION
The content of the door controller manual and particularly the safety instructions
must get note!
reset pins X3- 2
and X3- 1
JST connector 8-pole
Connector:
battery with connector (see 2.1)
M12, 8- polig,
cable 0,4m 4x2x0.25
2.1
Encoder:
battery change:
Attention
TST PDFSAS-0.0-A
Disconnecting the battery effects clearing of position values from the
encoder! After reconnecting the battery a RESET must be done. Do not short
or charge the battery. Do not store or operate the system above the
specified temperature range. Connecting the encoder with switched on
supply voltage is not allowed.
Antenna:
TST FSAS- 0.1-A- circuit
board- Antenna with 0.9m long
coaxial cable
To do an Reset you must make an short cut between the Reset pins
X3-2 and X3-1 for a short moment
3. Mounting of encoder:
1. Pin connections:
weiß/white
braun/brown
TST
PDFSAS
grün/green
gelb/ yellow
grau/grey
rosa/pink
blau/blue
rot /red
GND
+24V
RS485 B
RS485 A
(not used)
safety edge n o.
(safety edge 2 optional)
breakaway
34
31
36
35
Si2
screw M3 for
magnet holder fixing
Controller
FU3P
15.5 mm / 0.63 inch
...
17.5 mm / 0.69 inch
24.5 mm / 0.965 inch ...
26.5 mm / 1.04 inch
mounting plate
engine shaft or gear box shaft
D = 12.0 mm + 0 mm / -0.1 mm
D = 0.49 inch + 0 inch / -0.004 inch
Remarks:
- For connection shielded cables with M12 A-encoded plug are recommended. The
shield has to be connected to earth ground only on the controller side.
- The housing of the plug is not allowed to be connected to earth ground.
- Not used wires must be isolated inside of FU3P
magnet holder with magnet
The assembling tolerance from shaft center to sensor center is
maximum +/-1 mm (+/- 0.039 inch).
Torque for M3 screw / magnet holder fixing : maximum 0.4 Nm
FEIG ELECTRONIC GmbH ‹ Lange Str. 4 ‹ D-35781 Weilburg, Germany ‹ Tel.: +49 (0) 6471 / 3109-0 ‹ Fax: +49 (0) 6471 / 3109-99 ‹ www.feig.de ‹ Email:
info@feig.de PD_FSAS_Eng_150409.Doc
4. Mounting of the stationary Antenna:
6. Technical Data:
Side view
Connection data:
Supply voltage +24 V +/-10%, typical 50 mA.
Serial bidirectional Interface RS485 / 19,2k Baud
Digital outputs:
Three configurable outputs with the following standard setting:
Output 1 and 2: Safety output (N.O.) with 8.2kΩ terminal resistor
and testing of terminal resistor.
Output 3: Breakaway output
(N.C. contact at 24V with 560Ω limiting resistor)
Connecting to A-encoded M12 plug with 35cm long cable.
Front view
Antenna
Antenna
The max. allowed Length of the customer mounted cable is 50m
Radio :
Temperature range:
Mobile unit
Mobile unit
Figure: Mounting of Antenna on door
5. Stationary Antenna + aluminum mounting bracket:
45
12 0
aluminum mounting bracket
60
7,6
44
24,5
10
39
drill holes
15
4,2
84
Figure: Stationary Antenna + aluminum mounting bracket
Operating range 2400 to 2483.5MHz
40 channels, Rated output power 0dBm
Operating range –40 to +70°C,
Storage range –40 to +70°C (recommended +20°C)
Protection class:
IP65
Max. tolerable speed:
6000 U/min
Resolution:
13 Bit / turn (8192 Increments / turn)
Counter of turns:
15 Bit
Weight:
Without cable but with magnet holder 220g
Lifetime of battery:
typical 10 years
Dimensions (L x B x H):
Encoder 92 x 69.5 x 24mm
Antenna board 84 x 39 x 7.6mm (Antenna height 26mm)
7. FCC Statements:
Notice: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry
Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Notice: Changes or modifications made to this equipment not expressly approved by
FEIG ELECTRONIC may void the FCC authorization to operate this equipment.
Notice: This product has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures :
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected
Consult the dealer or an experienced radio / TV technician for help
FEIG ELECTRONIC GmbH ‹ Lange Str. 4 ‹ D-35781 Weilburg, Germany ‹ Tel.: +49 (0) 6471 / 3109-0 ‹ Fax: +49 (0) 6471 / 3109-99 ‹ www.feig.de ‹ Email:
info@feig.de PD_FSAS_Eng_150409.Doc

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:3e57cf26-ec72-4521-894f-e2be66bd5bec
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Create Date                     : 2009:04:15 11:05:22+02:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2009:04:15 11:05:22+02:00
Document ID                     : uuid:476cfe19-adf5-414e-9ac2-ce8ec96152a6
Format                          : application/pdf
Title                           : Microsoft Word - PD_FSAS_Eng_150409.doc
Creator                         : heinze
Author                          : heinze
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJMTSTPDFSAS

Navigation menu