Fiberstars WPC04 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1

Fiberstars, Inc. WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS WPC 1

USERS MANUAL

Download: Fiberstars WPC04 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1
Mirror Download [FCC.gov]Fiberstars WPC04 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1
Document ID829727
Application ID3qvheyhi3dbWj6MHC7bqeQ==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize85.67kB (1070936 bits)
Date Submitted2007-08-15 00:00:00
Date Available2007-08-16 00:00:00
Creation Date2007-07-19 13:12:40
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2007-07-19 13:13:10
Document TitleWPC-1
Document CreatorAcrobat PDFMaker 6.0 for Word
Document Author: FIBERSTARS

WPC-04R
Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
Installation Instructions: Read these instructions in
their entirety before performing any installation work.
FOR USE WITH POOL AND SPA PRODUCTS
ETL LISTED
Conforms to UL STD 508;
Certified to CSA STD
C22.2 No. 14
http://www.fiberstars.com
79-15103-00 REV. B
Page 1 of 11
The WPC-04R consists of the following parts:
Item No.
10
11
12
13
14
Qty.
12
Component part No.
42-15032-00
41-15004-08
10-15089-01
10-15089-07
37-15000-00
02-15287-00
02-15286-00
02-15285-00
38-15012-00
A10670
14-15032-00
94-15108-01
04-15045-00
94-15092-00
Description
Timer
8 Position Terminal Block
M3 Screw, 4MM Length
M3 Screw, 14MM Length
Relay
Base Plate
Timer and Switch Plate
Relay Cover
3 Position Rocker Switch
Screw, 8-32 x .25”
PCB Standoff
PCB
Enclosure
WPC Repeater
Accessory Items:
FP 1/2
WE-65
DL-HUB
Temperature Freeze Device
65 ft Repeater Cord Extension Kit
Direct Light Hub Connection Kit
13
11
12
10
14
http://www.fiberstars.com
79-15103-00 REV. B
Page 2 of 11
SAVE THESE INSTRUCTIONS!
IMPORTANT SAFETY INFORMATION
Basic safety precautions should be observed when operating the WPC-04R product and other
associated equipment.
1. A qualified electrician must install the WPC-04R in accordance to the National and Local
Electrical Codes.
2. The WPC-04R must not be less then 5 feet (3 meters in Canada) from inside edge of pool.
ONLY USE COPPER CONDUCTORS.
3. Do not exceed the maximum ratings of individual components, wiring devices, and current
carrying capacity of conductors.
4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-04R, refer to
Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code.
5. This device should never operate an equipment that could cause property damage, bodily injury,
or death should it be activated unexpectedly.
6. Never allow children to operate the WPC-04R unsupervised.
FCC WARNING
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by Fiberstars Inc. could void the user's
authority to operate the equipment.
ELECTRICAL RATINGS
Do not exceed the maximum electrical ratings of the WPC-04R. Install a 20Amp 120VAC Circuit
Breaker in the Breaker Panel for connection to the Time Clock Input. This Circuit Breaker is also
used for Light Input. Refer to pages 4 and 5 for installation instructions. Light circuit is rated for
8Amp 120VAC Max.
http://www.fiberstars.com
79-15103-00 REV. B
Page 3 of 11
WARNING
•
•
•
TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT.
ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY
QUALIFIED ELECTRICAL PERSONELL ONLY.
VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE.
LOCATION
Install the WPC-04R enclosure using the mounting plates included with each enclosure. The
WPC-04R is housed in a Type 3R rainproof enclosure and can be mounted anywhere between
the pool equipment and the breaker panel.
WIRING INSTRUCTIONS
FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL
REGULATORY REQUIREMENTS.
TC NEUTRAL
120V POWER
FROM GFCI LOAD
TC 120V INPUT
Power Connections:
To wire the WPC-04R use insulated
COPPER wire only, 12 gauge minimum.
Run a ½” to ¾” conduit from the main
breaker panel to the WPC-04R. Pull
appropriate wires from the main breaker
panel to the WPC-04R unit. To make
power connections remove 3/8 inches of
insulation from wire ends. Insert the
bare end of wires under the pressure
plate of terminals (Power Input, HOT).
Use 1/8-in. flat head screwdriver to
tighten terminal screws firmly (4.4 lb-in
minimum). Connect the house common
to the Power Inputs NEUTRAL
terminal. Connect another HOT wire to
the Timeclocks T/C POWER terminal.
Connect a house common to the
Timeclocks T/C NEUTRAL. Install a
20 Amp circuit breaker in the main
breaker panel and connect the HOT
wires from the WPC-04R.
NEUTRAL FROM
GFCI LOAD
GFCI
GROUND
NEUTRAL
120V LINE INPUT
http://www.fiberstars.com
79-15103-00 REV. B
Page 4 of 11
Hooking up Lights to Circuit 1
To connect a lighting product to the Circuit
1 switch, pull wires from the product to the
WPC-04R through conduits connected to
the bottom of the WPC-04R. As
illustrated, connect the light that will be
operated by the Rocker Switch to the Light
Hot terminal. Connect the Neutral to the
Light Neutral terminal. Connect the
Ground to the Light Ground terminal. Do
not exceed 8Amps per circuit.
LIGHT GROUND
LIGHT NEUTRAL
LIGHT HOT
http://www.fiberstars.com
79-15103-00 REV. B
Page 5 of 11
CONNECTING A 240VAC PUMP
Connect the 240VAC pump to the relay as
illustrated. Connect the Line Power to a
240VAC Circuit Breaker on the breaker
panel. Circuit Breaker should be rated to
correspond to Horsepower and Amperes
rating of Pump being used. NOT TO
EXCEED 1.5HP 120V/3HP 240V –
30Amps.
PRIMARY
240VAC PUMP
SECONDARY
http://www.fiberstars.com
79-15103-00 REV. B
Page 6 of 11
Repeater Mounting
The WPC-04R is equipped with a signal repeater that can be mounted up to 10 feet from the
WPC-04R unit. This repeater receives signals from the wireless remote and sends that signal to
the WPC-04R via the 10 foot cable. Establish a location for the Repeater that is in line of sight
from where the wireless remote will be used most frequently and that is no more then 75 feet from
furthest where the remote will be used. NOTE: If extension is needed, use Fiberstars part
number 94-15098-00 and follow installation instructions supplied with the Repeater Extension.
To mount the Repeater, carefully insert a small flathead screwdriver into groove between the
Dome and Base approximately where the locking dimples are located. Pry the Dome out of on of
the locking dimples. Then carefully insert the small flathead screwdriver into the groove between
the Dome and the Base in an adjacent locking dimple and pry the Dome out. Then separate the
Dome from the Base by hand. Using the supplied self-drilling screws, locate a suitable mounting
surface and screw the base to this surface. Note that the marking “TOP” must be in the 12
o’clock position and the wire slit must be in the 6 o’clock position. Do not over tighten the
screws as it may damage the Repeater base. Realign the Repeater Dome to the Base and ensure
that the wire is exiting the base through the slit and the Locking Dimples are aligned with the
Flathead Screwdriver
Repeater
Dome/Base groove
Locking
Dimple
10 feet
Mounting Screws
Orientation
Marker
Mounting
Holes
Repeater Dome
Base Slit for
Repeater Wire
Repeater Base
http://www.fiberstars.com
79-15103-00 REV. B
Page 7 of 11
OPERATING INSTRUCTIONS
WPC-04R ROCKER SWITCH OPERATION
The WPC-04R receiver box houses one rocker
switch. For operation with the wireless transmitter,
the switch needs to be in the DOWN or REMOTE
position. To manually turn ON the device connected
to the Rocker Switch, flip the Rocker Switch UP or
to the ON position. When the Rocker Switch is in
the ON position, the Wireless Remote will not be
able to turn OFF the device connected to the Rocker
Switch terminal. To turn OFF the device manually,
flip the Rocker Switch to the MIDDLE or OFF
position. NOTE: In the OFF position, the wireless
remote operation will be bypassed. To re-enable the
wireless remote operation, flip the Rocker Switch
back to the BOTTOM or REMOTE position.
NOTE: If the unit turns ON when the switch is
returned to the REMOTE position, simply use the
wireless remote to turn OFF the unit if desired.
WIRELESS REMOTE OPERATION
NOTE: The Rocker Switch on the WPC-04R
must be set to REMOTE for wireless operation.
The POWER ON/OFF button controls the device
connected to the Rocker Switch terminal. With
each push of the button, the WPC-04R toggles the
device ON and OFF.
NOTE: Switch is shown in the ON position.
Circuit 1 control
http://www.fiberstars.com
79-15103-00 REV. B
Page 8 of 11
TIMER OPERATION
Set time to current time. In the example below, the current time is set for 9:00pm. NOTE:
Only turn the Timer dial clockwise or the timer will be damaged. Once the time has been set to
the current time, set the hours of the Pump operation by “snapping” the timer tabs inwards
towards the center. NOTE: Each tab represents 15 minutes of operation and tabs set inwards
towards the center is for OFF operations and ON when the tabs are set outwards as illustrated.
In the example below, the Pump will be off from 12:00pm to 11:45pm.
Once the time and time of operation has been set, ensure that the Timer function switch is set to
Auto for timer control of the Pump as illustrated below. To turn off timers automatic functions,
set the Timer function switch to OFF. To manually turn on the Pump, set the Timer function
switch to the ON position. NOTE: When in the ON position, the Pump will continue to run
until the Timer function switch is set to Auto where the tabs at the Set Point is in the OFF
position or if the Timer function switch is rotated to the OFF position.
Timer tabs set to
ON position
Timer dial rotation
direction indicator
Timer tabs set to
OFF position
Current time and Timer
function switch set point
PM hours
AM hours
Timer function
switch
Timer dial
http://www.fiberstars.com
79-15103-00 REV. B
Page 9 of 11
For Freeze
Protect Switch
For Freeze
Protect Switch
http://www.fiberstars.com
79-15103-00 REV. B
Page 10 of 11
http://www.fiberstars.com
79-15103-00 REV. B
Page 11 of 11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 11
Language                        : EN-US
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:d42dd455-bb84-45cc-9100-1999b26626e8
Producer                        : Acrobat Distiller 6.0 (Windows)
Company                         : FIBERSTARS
Source Modified                 : D:20070719171235
Headline                        : 
Creator Tool                    : Acrobat PDFMaker 6.0 for Word
Modify Date                     : 2007:07:19 13:13:10-04:00
Create Date                     : 2007:07:19 13:12:40-04:00
Metadata Date                   : 2007:07:19 13:13:10-04:00
Document ID                     : uuid:6bf1ffc4-de55-462b-ab38-5255d3e6e6be
Version ID                      : 3
Format                          : application/pdf
Title                           : WPC-1
Creator                         : FIBERSTARS
Subject                         : 
Tagged PDF                      : Yes
Author                          : FIBERSTARS
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VF2-WPC04

Navigation menu