Fiberstars WPC2 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1
Fiberstars, Inc. WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS WPC 1
USERS MANUAL
WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL LISTED Conforms to UL STD 508; Certified to CSA STD C22.2 No. 14 79-15054-00 Rev. C http://www.fiberstars.com Page 1 of 18 The WPC2 single speed version consists of the following parts: Item 10 11 12 13 14 15 16 17 18 19 20 Qty. Component part No. 94-15089-00 37-15000-00 41-15004-08 42-15032-00 02-15269-00 02-15267-00 41-15003-00 94-15090-00 10-15086-04 10-15089-06 10-15060-01 10-15089-03 A11526 94-15092-00 10-15089-02 20-15013-00 02-15270-00 17-15005-00 10-15089-01 Description WPC-2 Enclosure WPC-2 Enclosure Door Relay 8 Position Terminal Block Timer Load Center Cover Plate WPC-2 Mounting Bracket Grounding Bar WPC Receiver Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws Terminal Block Mounting Screw Relay Mounting Screw Timer and Receiver Mounting Screws 3-Position Toggle Switch WPC Repeater Freeze Device Mounting Screw (Optional equipment) Strain Relief Switch Bracket Latch Latch Mounting Screws Accessory Items: FP 1/2 WE-65 WPC-2/3 ST DL-HUB TC-2 WPC-12V Temperature Freeze Device 65 ft Repeater Cord Extension Kit GFCI Mounting Kit Direct Light Hub Connection Kit Additional Timeclock/Dust Cover 12V Transformer for Fiberstars Light Streams LED Products 10 15 16 10 18 13 10 11 20 19 12 13 17 14 10 79-15054-00 Rev. C 10 http://www.fiberstars.com Page 2 of 18 The WPC2 dual speed version consists of the following parts: Item 10 11 12 13 14 15 16 17 18 19 20 21 Qty. Component part No. 94-15089-00 37-15001-00 41-15004-08 42-15032-00 02-15269-00 02-15267-00 41-15003-00 94-15090-00 10-15086-04 10-15089-06 A7000 10-15089-03 A11526 94-15092-00 10-15089-02 20-15013-00 02-15270-00 17-15005-00 10-15089-01 A8966 Description WPC-2 Enclosure WPC-2 Enclosure Door DPDT Relay 8 Position Terminal Block Timer Load Center Cover Plate WPC-2 Mounting Bracket Grounding Bar WPC Receiver Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws Terminal Block Mounting Screw Relay Mounting Nut Timer and Receiver Mounting Screws 3-Position Toggle Switch WPC Repeater Freeze Device Mounting Screw (Optional equipment) Strain Relief Switch Bracket Latch Latch Mounting Screws Relay Mounting Screw 10 15 16 21 10 18 13 10 11 20 19 13 12 17 14 10 79-15054-00 Rev. C 10 http://www.fiberstars.com Page 3 of 18 SAVE THESE INSTRUCTIONS! IMPORTANT SAFETY INFORMATION Basic safety precautions should be observed when operating the WPC-2 product and other associated equipment. 1. A qualified electrician must install the WPC-2 in accordance to the National and Local Electrical Codes. 2. The WPC-2 must not be less then 5 feet (3 meters in Canada) from inside edge of pool. ONLY USE COPPER CONDUCTORS. 3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. 4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-2, refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. 5. This device should never operate an equipment that could cause property damage, bodily injury, or death should it be activated unexpectedly. 6. Never allow children to operate the WPC-2 unsupervised. FCC WARNING 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by Fiberstars Inc. could void the user's authority to operate the equipment. 79-15054-00 Rev. C http://www.fiberstars.com Page 4 of 18 ELECTRICAL RATINGS Do not exceed the maximum electrical ratings of the WPC-2. A circuit breaker rated at 20Amps at 120VAC must installed in the breaker panel to connect to the WPC-2 power input. Circuit 1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is rated at a maximum of 3HP @ 240VAC. M ANUFACTURER Thomas & Bet t s Cut ler-Hammer Square D M urray Siemens/ ITE Challenger West inghouse or Bryant Crouse Hinds GE Regular SINGLE TB BR HOM M P-T QP BR MP THOP SUITABLE LISTED BREAKERS CIRCUIT BREAKER DOUBLE TWIN QUAD TB TBBD TBBQ BR BRD BRD HOM HOM T HOM T M P-T M H-T M H-T QP QT QT A-CT BQ TRIPLEX GFCB GFB GFCB HOM -GFI M P-GT QPF HAGF GFCB M P-GF THOP-GF Wiring Inf ormat ion - Copper Conduct ors Only Terminal Torque* Wire Size 75°C min. Insulat ion AWG 14 12 10 79-15054-00 Rev. C Supply Circuit Breaker Rat ing AM P 15 20 30 50 65 85 100 100/ 125 Line and Neut ral M ain Lugs LB-IN 35 35 35 40 45 45 50 50 Neut ral and Ground LB-IN 20 20 20 25 35 35 M ax M ot or Load (Cont inuous Dut y) 120V 240V HP HP 1/ 2 1 1/ 2 http://www.fiberstars.com General Purpose Branch Circuit Breaker Rat ing AM P 15 20 30 40 60 FILLER PLATE FP-1C-TB BRFP HOM FP LX100FP QF-3 # FC-1C FP-1 TQLFP-1 General Purpose Branch Circuit M aximum Current Capacit y AM P 12 16 24 32 44 Page 5 of 18 WARNING • • • TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT. ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL PERSONELL ONLY. VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE. LOCATION Install the WPC-2 enclosure using the mounting plates included with each enclosure. The WPC-2 is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool equipment and the breaker panel. WIRING INSTRUCTIONS FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL REGULATORY REQUIREMENTS. Power Connections: To wire the WPC-2 use insulated COPPER wire only, 12 gauge minimum. Run a ½” to ¾” conduit from the main breaker panel to the WPC-2. Pull appropriate wires from the main breaker panel to the WPC-2 unit. To make power connections remove 3/8 inches of insulation from wire ends. Connect bare wires to the Load Center as illustrated. Tighten terminal screws firmly (20 lb-in minimum). Connect the common to the Neutral bar (tighten to 20 lb-in minimum). Install a 20 Amp circuit breaker and wire to the 120V LINE and the T/C POWER of the terminal block. Wire the Neutral and T/C NEUTRAL terminals to the Neutral bar on the Load Center. For use with an internal GFCI, punch out the GFCI knockout on the Load Center Cover Plate of the WPC. Install a GFCI with appropriate hardware (sold separately from Fiberstars, part number WPC-2/3 ST). 79-15054-00 Rev. C NEUTRAL LOAD SIDE HOT LOAD SIDE T/C POWER T/C NEUTRAL 120VAC 20AMP CIRCUIT BREAKER HOT LINE SIDE GFCI TO NEUTRAL BAR http://www.fiberstars.com GROUND Page 6 of 18 Hooking up Lights to Circuit 1 and Circuit 2 To connect a lighting product to the Circuit 1 and Circuit 2 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Repeat for Circuit 2. Do not exceed 8Amps per circuit. NOTE: Some models with optional equipment will have Circuit 1 or Circuit 2 or both Circuits pre-wired for other functions. The WPC-3 is approved for use with the Intermatic Metallic Hub Kit (156PA14336A) and Fiberstars DL-HUB for direct connection of underwater lights. Refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. 79-15054-00 Rev. C http://www.fiberstars.com Page 7 of 18 Connecting Jazz, Jazz-Spa, System 6004, and System 6004-AS* For proper operation of these products both Circuit 1 and Circuit 2 must be wired so that the power is controlled through Circuit 1 and the color wheels functions are controlled through Circuit 2. Follow each products installation manual for proper installation. Run appropriately rated wires from the unit to the WPC-2 no less then 12 Gauge COPPER wires. Connect the Power to the Circuit 1 terminal at one end and to the BLACK wire on the Fiberstars unit. Connect the neutral to the NEUTRAL terminal in the WPC-2 and to the WHITE wire on the Fiberstars unit. Connect the grounding cable to the EQUIP. GND. and on the other end to the GREEN cable. Finally, for synchronization operation, connect the C/W CONTROL cable to the Circuit 2 terminal and on the other end to the RED wire on the Fiberstars unit. You may connect up to 8Amps of Fiberstars units to Circuit 1. NOTE: Some models with optional equipment will have Circuit 2 or Circuit 1 or both Circuits pre-wired for other functions and therefore eliminates the ability for this type of wiring. NEUTRAL LIGHT CONTROL C/W CONTROL The WPC-3 is approved for use with the Intermatic Metallic Hub Kit (156PA14336A) and Fiberstars DL-HUB for direct connection of underwater lights. Refer to 1999 NEC 680-21(b), 2002 NEC 68024(b) or CEC 68-060, 062 and 066 for details. * Or other two button Power/Color system, i.e. Pentair, Supervision, Fiberworks… 79-15054-00 Rev. C http://www.fiberstars.com Page 8 of 18 PUMP CONNECTIONS NOTE: Some models are ONLY equipped with Single Speed OR Dual Speed pump connections. CONNECTING A 240VAC PUMP Connect a 240V 30AMP Circuit Breaker for each pump (if this control box is equipped with optional pump relays). Using an appropriately sized copper wires connect to the outer contacts of the JQX relays of the appropriate pumps as shown. Run wires from the pump to the inner contacts of the appropriate JQX relay. NOTE: This unit maybe equipped with more then one JQX relay for pump control. LO SPEED 79-15054-00 Rev. C POWER IN NOTE: The Secondary 120V must be directly connected to the pump for 240V operation. 240V Circuit Breaker HI SPEED CONNECTING A 240VAC DUAL SPEED PUMP As illustrated, connect the Low Speed wire to the Low Speed Load terminal on the terminal block. Connect the High Speed wire to the High Speed Load terminal on the terminal block. Connect the 120V Primary from the 240V Circuit Breaker to the 120V PRI INPUT terminal. Directly connect the 120V Secondary from the Circuit Breaker to the 2 Speed Pump. 240VAC Pump 120V PRIMARY 240VAC CIRCUIT BREAKER 2 SPEED PUMP 120V SECONDARY CONNECTED TO 2 SPEED PUMP NOTE: Pump Breaker MUST be turned OFF before servicing as 2nd leg of 240V circuit is HOT at all time! http://www.fiberstars.com Page 9 of 18 24V Valve Wiring (Optional Equipment). To connect a 24V Valve, follow diagram as shown. Connect one leg of the 24V common to the 24V TO VALVE terminal. Connect the Close wire to the NC LOAD terminal and the Open wire to the NO LOAD terminal. COMMON TO VALVE CLOSE WIRE FROM VALVE OPEN WIRE FROM VALVE Heater Connection (Optional Equipment). To connect a heater, run the pilot wires from the heater to the WPC unit. Connect the wires to the terminal block labeled Heater. NOTE: The Heater circuit only completes the circuit of the Heater terminals when the 24V Valve control is energized to the NO Load circuit. TO HEATER TO HEATER 79-15054-00 Rev. C http://www.fiberstars.com Page 10 of 18 Single Speed Wiring Diagram FOR USE ON WPC-2 AUXILIARY RELAY KIT FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION 79-15054-00 Rev. C http://www.fiberstars.com Page 11 of 18 Dual Speed Wiring Diagram FOR USE ON WPC-2 AUXILIARY RELAY KIT FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION 79-15054-00 Rev. C http://www.fiberstars.com Page 12 of 18 Repeater Mounting The WPC-2 is equipped with a signal repeater that can be mounted up to 10 feet from the WPC-2 unit. This repeater receives signals from the wireless remote and sends that signal to the WPC-2 via the 10 foot cable. Establish a location for the Repeater that is in line of sight from where the wireless remote will be used most frequently and that is no more then 75 feet from furthest where the remote will be used. NOTE: If extension is needed, use Fiberstars part number 9415098-00 and follow installation instructions supplied with the Repeater Extension. To mount the Repeater, carefully insert a small flathead screwdriver into groove between the Dome and Base approximately where the locking dimples are located. Pry the Dome out of the locking dimples. Then carefully insert the small flathead screwdriver into the groove between the Dome and the Base in an adjacent locking dimple and pry the Dome out. Then separate the Dome from the Base by hand. Using the supplied self-drilling screws, locate a suitable mounting surface and screw the base to this surface. Note that the marking “TOP” must be in the 12 o’clock position and the wire slit must be in the 6 o’clock position. Do not over tighten the screws as it may damage the Repeater base. Realign the Repeater Dome to the Base and ensure that the wire is exiting the base through the slit and the Locking Dimples are aligned with the locking holes. Apply enough pressure so that the Dome “snaps” into the base. NOTE: Do not stuff the remainder of the Repeater wire into the WPC unit. Flathead Screwdriver Repeater Dome/Base groove 10 feet Locking Dimple Mounting Screws Orientation Marker Mounting Holes Repeater Dome 79-15054-00 Rev. C Base Slit for Repeater Wire Repeater Base http://www.fiberstars.com Page 13 of 18 OPERATING INSTRUCTIONS WPC-1 TOGGLE SWITCH OPERATION The WPC-1 receiver box houses two switches. For operation with the wireless transmitter, the switches need to be in the REMOTE position. To manually turn ON the devices connected to either Circuit 1 or Circuit 2, flip the switches to the ON position. When a circuit is in the ON position, the Wireless Remote will not be able to turn OFF the respective circuit. To turn OFF the devices manually, flip the respective switch to the MIDDLE or OFF position. NOTE: In the OFF position, the wireless remote operation will be bypassed. To re-enable the wireless remote operation, flip the switch back to the REMOTE position. NOTE: If the units turn ON when the switch is returned to the REMOTE position, simply use the wireless remote to turn OFF the units if desired. WIRELESS REMOTE OPERATION NOTE: The toggle switches on the WPC-1 must be set to REMOTE for wireless operation. The POWER ON/OFF buttons control the individual circuits independently. With each push of the button, the WPC-1 toggles the individual circuits from ON to OFF and vice versa. For Synchronization operation, simply push the SYNC ON/OFF button. NOTE: If all circuits are off when the SYNC ON/OFF button is pressed, all circuits will be turned to ON. If any one of the circuits are in the ON state by the wireless remote, then when the SYNC ON/OFF button is pressed all circuits will be turned OFF and the SYNC ON/OFF must be pressed to turn all circuits on simultaneously. 79-15054-00 Rev. C Units equipped with toggle switches NOTE: Circuit 1 is in the ON position and Circuit 2 is in the REMOTE position Units equipped with rocker switches NOTE: Switch is shown in the ON position. Circuit 1 control Circuit 2 control For Synchronization of Circuit 1 and Circuit 2 http://www.fiberstars.com Page 14 of 18 TIMER OPERATION Set time to current time. Open timer cover by lifting from the bottom towards you. In the example below, the current time is set for 9:00 pm. NOTE: Only turn the Timer dial clockwise or the timer will be damaged. Once the time has been set to the current time, set the hours of the Pump operation by “snapping” the timer tabs inwards towards the center. NOTE: Each tab represents 15 minutes of operation and tabs set inwards towards the center is for OFF operations and ON when the tabs are set outwards as illustrated. In the example below, the Pump will be off from 12:00 pm to 11:45 pm. Once the time and time of operation has been set, ensure that the Timer function switch is set to Auto for timer control of the Pump as illustrated below. To turn off timers automatic functions, set the Timer function switch to OFF. To manually turn on the Pump, set the Timer function switch to the ON position. NOTE: When in the ON position, the Pump will continue to run until the Timer function switch is set to Auto where the tabs at the Set Point is in the OFF position or if the Timer function switch is rotated to the OFF position. Apply the timer label to the timer cover plate. Close the timer cover firmly after timer is set. Timer Cover Timer Plate Timer tabs set to ON position Timer dial rotation direction indicator Timer tabs set to OFF position Current time and Timer function switch set point PM hours AM hours Timer function switch Timer dial 79-15054-00 Rev. C http://www.fiberstars.com Page 15 of 18 CODE ADJUSTMENTS If it is necessary to change the transmission code on the WPC-2 an adjustment to the receiver AND the transmitter DIP switches must be performed. RECEIVER DIP SWITCHES – Turn OFF power to the WPC-2 from the circuit breaker on the Load Center or from Main Power. Open the enclosure door. Unscrew and remove the Load Center Cover Plate. Place the Cover Bracket in a safe location. Unscrew and remover the Switch Bracket. Disconnect the Molex connector that connects the Switch Bracket controls to the receiver unit and set the Switch Bracket in a safe location where it will not be bent, scratched, or impact forces applied to the components or the face plate itself. Unscrew the four (4) screws holding the receiver to the base of the WPC-2 control box. Unscrew the four (4) screws located on the back of the receiver to release the cover. NOTE: Take notice of how the wires enter and exit the receiver. Remove the cover and look on the PCB to locate the DIP switch as illustrated. TRANSMITTER DIP SWITCHES – Remove all screws from rear of remote. Separate the bottom cover from the top cover. DIP SWITCH ADJUSTMENT – The four DIP switches have an ON and an OFF position. Changing just one DIP switch will change the code. MAKE SURE BOTH THE RECEIVER AND TRANSMITTER HAVE THE SAME DIP SWITCH SETTINGS. Molex Connector Receiver Mounting Holes Switch Bracket Rear screws DIP Switch Mounting Screws Load Center Cover Plate DIP switch Receiver screws 79-15054-00 Rev. C http://www.fiberstars.com Page 16 of 18 Note: Sample shown is of Channel 9 CHANNEL DIP SWIT CH Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 79-15054-00 Rev. C OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON http://www.fiberstars.com 13 10 14 11 15 12 16 DIP Switch Page 17 of 18 WPC FUNCTION CHART Below is a chart of the WPC functionality based on the model number. WPC2 Pump Features Button 1 Features Button 2 Features Other Options X – Standard 1 – Load Center Removed X – Standard 1 – T/C Bypass 2 – T/C Bypass & JVA Valve 3 – WFPR added for Booster Pump Accessories X – Standard 1 – Freeze Protect 2 – T/C w/Relay for Pool Booster Pump Cleaner 5 – FP & T/C w/Relay for Pool Cleaner Pump X – Standard 3 – WFPR added for Booster Pump X –1 Speed Pump – Standard 2 – 2 Speed Pump – 24/7 LO Speed, T/C controls HI Speed 3 – 2 Speed Pump w/T.C. for Lo Speed & T/C for Hi Speed EXAMPLE: WPC2-2X2X-1 is a 2 speed pump model with the Low Speed ON continuously until High Speed is actuated by the Time Clock. Button 1/Circuit 1 is wired standard. Button 2/Circuit 2 is wired as a Time Clock Bypass & JVA which actuates a JVA valve and turns on the High Speed pump (if Time Clock is already ON, then this action will keep the High Speed ON even after the Time Clock has Shut OFF) with the push of the Button 2 on the remote or flipping the Circuit 2 switch to ON. And this equipment is equipped with a Freeze Protect device which will turn on the High Speed pump when outside temperatures drop near freezing. 79-15054-00 Rev. C http://www.fiberstars.com Page 18 of 18
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 18 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:59a25fd1-5f56-45ef-ba0f-ee24e5161e71 Producer : Acrobat Distiller 6.0 (Windows) Company : FIBERSTARS Source Modified : D:20070719170113 Headline : Creator Tool : Acrobat PDFMaker 6.0 for Word Modify Date : 2007:07:19 13:02:27-04:00 Create Date : 2007:07:19 13:01:20-04:00 Metadata Date : 2007:07:19 13:02:27-04:00 Document ID : uuid:618c1a87-caf2-487f-ad6d-829f1add3717 Version ID : 7 Format : application/pdf Title : WPC-1 Creator : FIBERSTARS Subject : Tagged PDF : Yes Author : FIBERSTARSEXIF Metadata provided by EXIF.tools