DSX-602 CableAnalyzer™ Users Manual Software Version 5.1 May 2017 ©2017 Fluke Corporation All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service unless stated otherwise herein. The warranty period for the mainframe is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption. Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks. Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. To the extent permitted by law, Fluke Networks reserves the right to invoice Buyer for repair/replacement when a product purchased in one country is submitted for repair in another country. For a list of authorized resellers, visit www.flukenetworks.com/wheretobuy. Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB destination). Fluke Networks assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination). If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping point). THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decisionmaker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. 4/15 Fluke Networks PO Box 777 Everett, WA 98206-0777 USA Contents Chapter 1 Get Acquainted Overview of Features ......................................................1 Contact Fluke Networks .................................................2 Register Your Product ....................................................2 Additional Resources ......................................................2 Supplements and Updated Manuals .............................3 Kit Contents ....................................................................3 Symbols ............................................................................3 WSafety Information ....................................................4 Connectors, Keys, and LEDs ............................................8 About Link Interface Adapters ......................................12 AC Adapter and Battery .................................................14 Charge the Battery ...................................................14 Check the Battery Status ..........................................15 Verify Operation .............................................................16 How to Use the Touchscreen .........................................18 Change the Language ....................................................20 Buttons to Do Tests and Save Results ............................20 Overview of Memory Functions .....................................22 Options for Cable IDs ......................................................22 About LinkWare Applications ........................................23 LinkWare PC Cable Test Management Software ....23 The LinkWare Live Web Application .......................23 LinkWare Stats ..........................................................24 DSX-602 CableAnalyzer Users Manual Chapter 2 Certify Twisted Pair Cabling The DSX-602 CableAnalyzer Home Screen ................... 25 Make Sure Your Tester is Ready to Certify Cabling ............................................................................ 28 Set the Reference ........................................................... 29 Settings for Twisted Pair Tests ....................................... 31 How to Do an Autotest .................................................. 36 “Bad Patch Cord” Message ............................................ 39 Twisted Pair Autotest Results ........................................ 40 PASS*/FAIL* Results ................................................. 41 WIRE MAP Tab ......................................................... 42 PERFORMANCE Tab ................................................. 44 Frequency-Domain Results ...................................... 45 How to Save Frequency-Domain Results as a Plot or a Table ............................................ 45 DIAGNOSTIC Tab ...................................................... 50 Continuous Tests ...................................................... 51 Chapter 3 Certify Coaxial Cabling Set the Reference for Coaxial Tests ............................... 53 Settings for Coaxial Tests ............................................... 55 How to Do an Autotest .................................................. 57 Coaxial Autotest Results ................................................ 60 About Splitters ............................................................... 61 Tests Without a Remote ................................................ 62 Continuous Tests ............................................................ 65 Chapter 4 Manage Test Results View Saved Results ......................................................... 67 How to Replace a Saved Result that Failed .................. 70 ii Contents Delete, Rename, and Move Results ............................... 70 Manage Results on a Flash Drive ................................... 72 Upload Results to a PC ................................................... 73 View the Memory Status ................................................ 74 Chapter 5 Use Projects Why Use Projects? .......................................................... 75 Set Up a Project .............................................................. 76 The PROJECT Screen ....................................................... 76 The CABLE ID SETUP Screen ........................................... 78 About Next ID Sets ......................................................... 80 Manage Projects on a Flash Drive ................................. 81 Copy Project Settings to Other Testers ......................... 82 Chapter 6 Sync Projects with LinkWare™ Live Sign Up for a LinkWare Live Account ........................... 83 How to See the Tester’s MAC Address .......................... 84 Use LinkWare Live Through a Wired Ethernet Network .......................................................................... 84 Use LinkWare Live Through a Wi-Fi Ethernet Network .......................................................................... 85 Change the Network Settings ....................................... 88 Settings for the Wired Port ..................................... 88 Settings for the Wi-Fi Port ....................................... 88 Delete Wi-Fi Settings and Passwords ...................... 90 About the Asset Management Service .......................... 90 Sign Your Tester Out of LinkWare Live ......................... 91 Sign In to LinkWare Live from a Desktop or Mobile Device .......................................................... 91 Import Projects from LinkWare Live into LinkWare PC ..................................................................................... 91 iii DSX-602 CableAnalyzer Users Manual Learn More About LinkWare Live ................................. 91 Chapter 7 Maintenance Verify Operation ............................................................ 94 Clean the Tester ............................................................. 94 See Information About the Tester ................................ 95 Update the Software ..................................................... 95 Use a PC to Update the Software ........................... 96 Use an Updated Main Tester to Update Other Testers ....................................................................... 97 Use LinkWare Live to Update the Software ........... 99 Extend the Life of the Battery ....................................... 100 Store the Tester .............................................................. 100 Remove the Battery ....................................................... 100 Traceable Calibration Period ......................................... 101 Options and Accessories ................................................ 101 If the Tester Does Not Operate as Usual ....................... 102 iv List of Figures Figure Page 1. Main Tester Connectors, Keys, and LEDs.....................................8 2. Remote Tester Connectors, Keys, and LEDs ................................10 3. How to Attach and Remove Link Interface Adapters.................12 4. How to Prevent Damage to the Permanent Link Adapter Cables......................................................................13 5. LEDs Show the Remote’s Battery Status......................................15 6. Connections to See the Status of a Remote’s Battery ................17 7. How to Zoom the Screen..............................................................19 8. FIX LATER, TEST AGAIN, and TEST Buttons and the TEST Key..................................................................................20 9. The Home Screen for the DSX-602 CableAnalyzer .....................26 10. Reference Connections for Twisted Pair Cable ...........................30 11. Outlet Configurations ..................................................................35 12. Equipment for Autotests on Twisted Pair Cable.........................36 13. Permanent Link Connections .......................................................38 14. Channel Connections....................................................................39 15. PASS* and FAIL* Results...............................................................41 16. WIRE MAP Tab ..............................................................................42 17. PERFORMANCE Tab ......................................................................44 18. Tabular Results Screen for a Frequency-Domain Test ................46 19. Plot Screen for a Frequency-Domain Test ...................................48 20. Examples of Diagnostic Screens ...................................................50 21. Reference Connections for Tests on Coaxial Cabling .................54 22. Equipment for Tests on Coaxial Cabling .....................................57 23. Examples of Connections for Tests on Coaxial Cabling..............59 DSX-602 CableAnalyzer Users Manual 24. Autotest Results for Coaxial Cabling .......................................... 60 25. Connections for Coaxial Tests Without a Remote...................... 64 26. RESULTS Screen ............................................................................ 68 27. How to Connect the Tester to a PC............................................. 74 28. PROJECT Screen ............................................................................ 77 29. CABLE ID SETUP Screen (after you enter the first and last IDs) ........................................ 79 30. SYNC PROJECTS Screen ................................................................ 86 31. How to Connect the Tester to a PC............................................. 97 32. How to Connect Units Together to Update the Software......... 98 33. How to Remove the Battery ........................................................ 101 Chapter 1: Get Acquainted Overview of Features The DSX-602 CableAnalyzer main and remote units are rugged, hand-held testers that let you certify, troubleshoot, and document copper network cabling. The DSX-602 includes these features: The testers certify twisted pair cabling to Cat 6A/Class EA limits (500 MHz) in less than 10 seconds. Gives a PASS or FAIL result based on a test limit that you specify. You can save approximately 12,700 Cat 6A Autotest results, with plot data, in the tester’s internal memory. You can save more results on a removable flash drive. Taptive™ user interface lets you quickly navigate through different views of the results and see more information about cables. ProjX™ management system lets you set up projects to specify the types of tests and the cable IDs necessary for a job and monitor the progress and status of the job. You can connect the tester to a wired or Wi-Fi network and use the LinkWare™ Live web application to manage your projects from a desktop or mobile device. LinkWare PC software lets you upload test results to a PC and make professional-quality test reports. LinkWare Stats software makes browsable, graphical reports of cable test statistics. DSX-602 CableAnalyzer Users Manual Contact Fluke Networks www.flukenetworks.com/support info@flukenetworks.com 1-800-283-5853, +1-425-446-5500 Fluke Networks 6920 Seaway Boulevard, MS 143F Everett WA 98203 USA Fluke Networks operates in more than 50 countries worldwide. For more contact information, go to our website. Register Your Product Registering your product with Fluke Networks gives you access to valuable information on product updates, troubleshooting tips, and other support services. If you purchased a Gold Support plan, registration also activates your plan. To register your product, use LinkWare PC software. Additional Resources The Fluke Networks Knowledge Base answers common questions about Fluke Networks products and provides articles on cable testing techniques and technology. To access the Knowledge Base, log on to www.flukenetworks.com, then click SUPPORT > Knowledge Base. Supplements and Updated Manuals If necessary, Fluke Networks will put a supplement for this manual, or an updated manual, on the Fluke Networks website. To see if a supplement or updated manual is available, log on to www.flukenetworks.com, click SUPPORT > Manuals, then select a product. Chapter 1: Get Acquainted Kit Contents Kit Contents For a list of the contents of your DSX-602 kit, see the list that came in the product’s box or see the lists of models and accessories on the Fluke Networks website. If something is damaged or missing, contact the place of purchase immediately. Symbols Table 1 shows the symbols used on the tester or in this manual. Table 1. Symbols Warning: Risk of fire, electric shock, or personal injury. Warning or Caution: Risk of damage or destruction to equipment or software. See explanations in the manuals. Consult the user documentation. Do not connect this equipment to public communications networks, such as telephone systems. 40 year Environment Friendly Use Period (EFUP) under China Regulation - Administrative Measure on the Control of Pollution Caused by Electronic Information Products. This is the period of time before any of the identified hazardous substances are likely to leak out, causing possible harm to health and the environment. -continued- This product complies with the WEEE Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste. To return unwanted products, contact the manufacturer’s web site shown on the product or your local sales office or distributor. DSX-602 CableAnalyzer Users Manual Table 1. Symbols Conformite Europeene. Conforms to requirements of European Union directives. Safety requirements for electrical equipment for measurement, control, and laboratory use. Conforms to relevant North American standards. Conforms to relevant Australian standards. « Conforms to relevant Russian standards. Ã KCC-REM-FKN-012001001: EMC approval for Korea Class A Equipment (Industrial Broadcasting & Communication Equipment) This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. This key turns the tester on and off. WSafety Information WWarningX To prevent possible fire, electric shock, or personal injury: Read all safety information before you use the Product. Carefully read all instructions. Do not open the case. You cannot repair or replace parts in the case. Do not modify the Product. Use only replacement parts that are approved by Fluke Networks. Chapter 1: Get Acquainted WSafety Information Do not touch voltages > 30 V AC rms, 42 V AC peak, or 60 V DC. Do not use the Product around explosive gas, vapor, or in damp or wet environments. Use this Product indoors only. Use the Product only as specified, or the protection supplied by the Product can be compromised. Do not use and disable the Product if it is damaged. Do not use the Product if it operates incorrectly. Do not connect the tester to telephony inputs, systems, or equipment, including ISDN inputs. Doing so is a misapplication of this product, which can cause damage to the tester and make a possible shock hazard for the user. Always turn on the tester before you connect it to a link. Doing so activates the tester’s input protection circuitry. Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible. Remove the input signals before you clean the Product. Do not put metal objects into connectors. Batteries contain hazardous chemicals that can cause burns or explode. If exposure to chemicals occurs, clean with water and get medical aid. Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product. Replace the rechargeable battery after 5 years of moderate use or 2 years of heavy use. Moderate use is defined as recharged twice a week. Heavy use is defined as discharged to cutoff and recharged daily. DSX-602 CableAnalyzer Users Manual Disconnect the battery charger and move the Product or battery to a cool, non-flammable location if the rechargeable battery becomes hot (>50 °C, >122 °F) during the charge period.The battery door must be closed and locked before you operate the Product. The battery door must be closed and locked before you operate the Product. Repair the Product before use if the battery leaks. Recharge the batteries when the low battery indicator shows to prevent incorrect measurements. Turn off the Product and disconnect all test leads, patch cords, and cables before you replace the battery. Do not disassemble or crush battery cells and battery packs. Do not put battery cells and battery packs near heat or fire. Do not put in direct sunlight. Have an approved technician repair the Product. Use only AC adapters approved by Fluke Networks for use with the Product to supply power to the Product and charge the battery. Chapter 1: Get Acquainted WSafety Information WCaution To prevent damage to the tester or cables under test, to prevent data loss, and to make sure your test results are as accurate as possible: Do not connect the tester to an active network. Doing so causes unreliable test results, can disrupt network operations, and can cause damage to the tester. Connect only RJ45 plugs to the adapters. Other types of plugs, such as RJ11 (telephone) plugs, can cause permanent damage to the jacks. To make sure your test results are as accurate as possible, do the reference procedure every 30 days. See “Set the Reference” on page 29. Do not operate portable transmitting devices, such as walkie-talkies and cell phones, during a cable test. Doing so can cause errors in test results. For permanent link adapters, do not twist, pull on, pinch, crush, or make kinks in the cables. See Figure 4 on page 13. Do not remove the USB flash drive while the LED on the drive flashes. Doing so can corrupt the data on the drive. You can lose a USB flash drive, cause damage to it, or accidentally erase the contents of the drive. Thus, Fluke Networks recommends that you save no more than one day of test results on a flash drive, or that you upload results to LinkWare Live. See Chapter 4. DSX-602 CableAnalyzer Users Manual Connectors, Keys, and LEDs BK88.EPS Figure 1. Main Tester Connectors, Keys, and LEDs Connector for a link interface adapter LCD display with touchscreen : Starts a test. Turns on the tone generator if a remote tester is not connected to the main tester. To start a test, you can also tap TEST on the display. : Power key Chapter 1: Get Acquainted Connectors, Keys, and LEDs : Press to go to the home screen. Connector for the AC adapter. The LED is red when the battery charges, and green when the battery is fully charged. The LED is yellow if the battery will not charge. See “Charge the Battery” on page 14. RJ45 connector: Lets you connect to a network for access to Fluke Networks cloud services. Micro-AB USB port: This USB port lets you connect the tester to a PC so you can upload test results to the PC and install software updates in the tester. Type A USB port: This USB host port lets you save test results on a USB flash drive. Headset jack Note If you have two main testers, you can use one as a remote. To select the remote function, tap TOOLS > Main as Remote. DSX-602 CableAnalyzer Users Manual BK42.EPS Figure 2. Remote Tester Connectors, Keys, and LEDs Connector for a link interface adapter PASS LED comes on when a test passes. TEST LED comes on during a test. FAIL LED comes on when a test fails. TALK LED comes on when the talk function is on (). The LED flashes until the main tester accepts the request to talk. 10 Chapter 1: Get Acquainted Connectors, Keys, and LEDs TONE LED flashes and the tone generator comes on if you press when a main tester is not connected to the remote. LOW BATTERY LED comes on when the battery is low. The LEDs also have these functions: Battery gauge (see Figure 5 on page 15) Volume indicator for the TALK function Progress indicator for software updates : Starts a test. Turns on the tone generator if a main tester is not connected to the remote. : Power key : Press to use the headset to speak to the person at the other end of the link. Press again to adjust the volume. To turn off the talk function, hold down . Connector for the AC adapter. The LED is red when the battery charges, and green when the battery is fully charged. The LED is yellow if the battery will not charge. See “Charge the Battery” on page 14. Micro-AB USB port: This USB port lets you connect the tester to a PC so you can install software updates in the tester. Headset jack 11 DSX-602 CableAnalyzer Users Manual About Link Interface Adapters Link interface adapters let you connect the DSX-602 CableAnalyzer to different types of twisted pair links. Figure 3 shows how to attach and remove adapters. WCaution To prevent damage to the cables on the permanent link adapters and to make sure your test results are as accurate as possible, do not twist, pull on, pinch, crush, or make kinks in the cables. See Figure 4 on page 13. BK109.EPS Figure 3. How to Attach and Remove Link Interface Adapters 12 Chapter 1: Get Acquainted About Link Interface Adapters 5 in (13 cm) minimum GPU108.EPS Figure 4. How to Prevent Damage to the Permanent Link Adapter Cables 13 DSX-602 CableAnalyzer Users Manual AC Adapter and Battery You can use the AC adapter (model PWR-SPLY-30W) or the lithium ion battery (model VERSIV-BATTERY) to supply power to the tester. To remove the battery, see “Remove the Battery” on page 100. Charge the Battery Before you use the battery for the first time, charge the battery for about 2 hours with the tester turned off. To charge the battery Connect the AC adapter to the 15V jack on the left side of the tester. The LED near the AC adapter connector is red when the battery charges, and green when the battery is fully charged. A fully-charged battery operates for approximately 8 hours of typical use. The battery takes approximately 4 hours to fully charge when the tester is turned off. Notes You do not need to fully discharge the battery before you recharge it. The battery will not charge if its temperature is outside the range of 32 °F to 104 °F (0 °C to 40 °C). The LED near the connection for the AC adapter is yellow if the battery will not charge. 14 Chapter 1: Get Acquainted AC Adapter and Battery Check the Battery Status On a main tester The battery status icon is in the upper-left corner of the screen: Battery is full. Battery is approximately half full. If the AC adapter is not connected, the red bar shows that the battery is very low. Connect the AC adapter to charge the battery and make sure the tester continues to operate. The red bar also shows if the AC adapter is connected, but the battery is not installed. On a remote The LEDs show the battery status at the end of the power-up sequence, as shown in Figure 5. 84 % - 100 % 67 % - 83 % 51 % - 66 % 34 % - 50 % 18 % - 33 % 0 % - 17 % BK102.EPS Figure 5. LEDs Show the Remote’s Battery Status 15 DSX-602 CableAnalyzer Users Manual To see more information about a remote’s battery status Make the connections shown in Figure 6 and turn on both testers. Make sure the connection icon shows at the top of the screen ). Tap TOOLS, then tap Battery Status. When the AC adapter is not connected, the screen shows the Time Remaining, which is the approximate battery life at the present rate of use. Verify Operation The tester does a self test when you turn it on. If the tester shows an error or does not turn on, refer to “If the Tester Does Not Operate as Usual” on page 102. 16 Chapter 1: Get Acquainted Verify Operation DSX-602 with two channel adapters and a patch cord DSX-602 with permanent link and channel adapters BK148.EPS Figure 6. Connections to See the Status of a Remote’s Battery 17 DSX-602 CableAnalyzer Users Manual How to Use the Touchscreen The DSX-602 main unit’s Taptive™ user interface lets you use a touchscreen to control the tester. You can operate the touchscreen with your fingertip or with a stylus that is made for projected capacitance touchscreens. WCaution For correct operation and to prevent damage to the touchscreen: Touch the screen only with your fingers or with a stylus that is made for projected capacitance touchscreens. Do not use too much force. Do not touch the screen with sharp objects. Note The touchscreen will not respond if you tap it with your fingernail or an incorrect type of stylus or if you wear non-conductive gloves. To use the touchscreen To select an item on the screen, tap the item lightly with your fingertip. To scroll a screen, lightly touch the screen then move your fingertip in the direction you want the screen to move. On screens that show a plot, you can drag the measurement cursor. These screens also have a zoom function, as shown in Figure 7. To clean the touchscreen Turn off the tester, then use a soft, lint-free cloth that is moist with a mild detergent. WCaution When you clean the touchscreen, do not let liquid get under the plastic around the touchscreen. 18 Chapter 1: Get Acquainted How to Use the Touchscreen To zoom in, use the reversepinch gesture To move the image, drag it in any direction. To zoom out, use the pinch gesture To quickly go back to 1:1 magnification, double-tap the screen. BA45.EPS Figure 7. How to Zoom the Screen 19 DSX-602 CableAnalyzer Users Manual Change the Language On the home screen, tap the TOOLS icon, tap Language, then tap a language. Buttons to Do Tests and Save Results When a test is completed and more than one button shows at the bottom of the screen, the tester highlights one in yellow to recommend which one to tap. Figure 8 shows the buttons you will see. Note To change the Auto Save setting, tap the Next ID panel on the home screen. BK40.EPS Figure 8. FIX LATER, TEST AGAIN, and TEST Buttons and the TEST Key 20 Chapter 1: Get Acquainted Buttons to Do Tests and Save Results SAVE (yellow), TEST (gray): These buttons show if the test passed and Auto Save is off. When you tap SAVE, you can save the results with an ID that you make or select. When you tap TEST, you can select to save the results or do the test again and not save the results. UNSAVED RESULT: This button shows if Auto Save is off and you go to the home screen when a test is completed. Tap this button to see the result. FIX LATER: This button shows if the test failed or had a PASS* result and the result has not been saved. TEST AGAIN: This button shows if the test failed or had a PASS* result. Tap this button to do the test again. If Auto Save is on, the tester saves subsequent results with the same ID. If the test fails again, you can tap FIX LATER to save the result if necessary. When you look at a saved result that failed, tap TEST AGAIN to do the test again for the same ID and with the same test settings as the saved result. TEST (yellow): This button shows if the test passed and Auto Save is on. When Auto Save is on, the tester saves results with the next available ID when the test is completed. When you tap TEST, the tester does a test for the next available ID. : The key does the same function as the TEST button. When TEST AGAIN shows, you can press to do a test on the next ID. 21 DSX-602 CableAnalyzer Users Manual Overview of Memory Functions You can save approximately 12,700 Cat 6A Autotest results, with plot data included, in the DSX-602 main tester. The capacity available for test results depends on the space used by the software and custom test limits in the tester. To see the memory status On the home screen, tap the TOOLS icon, then tap Memory Status. To make more memory available, you can export results to a USB flash drive, then delete the results in the tester. See “Manage Results on a Flash Drive” on page 72. Options for Cable IDs When you save the test results for a cable, you usually give the results the name that is the ID for the cable. There are several methods you can use to make IDs for test results: You can use the CABLE ID SETUP screen to make a set of sequential IDs. The tester uses the IDs in sequence as the names for the results you save. When Auto Save is on, the tester automatically saves each result with the next available ID in the set. A cable ID set also lets you use IDs again so you can add different results to tests you saved before. 22 You can enter an ID each time you do a test. To do this, turn off the Auto Save function (see page 23). Each time a test is completed, tap SAVE (if the test passed) or FIX LATER (if the test failed), then enter an ID manually. You can use LinkWare PC software to make a set of IDs, download the set to the tester, then import it into a project. After you do a test, you can enter the ID for a test you saved before. This lets you replace results. Chapter 1: Get Acquainted About LinkWare Applications If the test failed before, and you saved the results, you can select it on the RESULTS screen, then press TEST AGAIN to replace the results for that ID. Notes Cable IDs are case-sensitive. For example, the tester saves result with the names “A0” and “a0” in two different records. A cable ID can have a maximum of 60 characters. If you delete all the ID sets in a project, the tester makes a default set that starts with 001. To turn the Auto Save function on or off On the home screen, tap the Next ID panel. On the CHANGE ID screen, tap the On/Off control next to Auto Save. Tap DONE. About LinkWare Applications LinkWare PC Cable Test Management Software The LinkWare PC Cable Test Management software lets you upload test records to a PC, organize and examine test results, print professional-quality test reports, and do software updates and other maintenance procedures on your tester. You can download LinkWare PC from the Fluke Networks website. The LinkWare Live Web Application The LinkWare Live web application lets you manage your projects from a desktop or mobile device. To get started with LinkWare Live, see Chapter 6. 23 DSX-602 CableAnalyzer Users Manual LinkWare Stats The LinkWare Stats Statistical Report software that is included with LinkWare PC software provides statistical analysis of cable test reports and generates browsable, graphical reports. For instructions about LinkWare PC and LinkWare Stats software, see the guides for getting started and the online help available under Help on the LinkWare PC and LinkWare Stats menus. 24 Chapter 2: Certify Twisted Pair Cabling WWarningX Before you use the DSX-602 CableAnalyzer, read the safety information that starts on page 3. The DSX-602 CableAnalyzer Home Screen The home screen (Figure 9) shows important test settings. Before you do a test, make sure these settings are correct. 25 DSX-602 CableAnalyzer Users Manual LM N BK110.EPS Figure 9. The Home Screen for the DSX-602 CableAnalyzer PROJECT: The project contains the settings for a job and helps you monitor the status of a job. When you save test results, the tester puts them in the project. Tap the PROJECT panel to edit the project settings, select a different project, or make a new project. Shows a summary of the test results in the project: : The number of tests that passed. 26 Chapter 2: Certify Twisted Pair Cabling The DSX-602 CableAnalyzer Home Screen : The number of tests that failed. : The number of tests with an overall marginal result. The test setup panel shows the settings the tester will use when you tap TEST or press . To change these settings, tap the panel. Icons show the status of the Store Plot Data and AC Wire Map settings. See Table 2 on page 33. Next ID: The Next ID panel shows the ID that the tester gives to the next test results you save. Tap Next ID to do these tasks: Enter an ID, select a different ID in the ID set, select a different set of IDs, or make a new set. The tester adds the IDs and ID sets you make to the project that shows on the home screen. Turn Auto Save on or off. Operator: The name of the person who does the job. You can enter a maximum of 20 operator names. For each operator you can also enter the email address that the operator will use as an ID to sign in to LinkWare Live. TOOLS: The TOOLS menu lets you set the reference, see the status of the tester, and set user preferences such as the language and the display brightness. RESULTS: Tap RESULTS to see and manage the results that are saved in the tester. SYNC: Tap SYNC to sync projects with LinkWare Live. TEST: Tap TEST to do the test shown in the test setup panel. The percentage of the project that is completed. The percentage is the number of IDs used for saved results divided by the total number of used and available IDs in the project. % Tested does not show if your project contains only a Next ID list. See “Each project can have up to 5000 IDs. If an ID set does 27 DSX-602 CableAnalyzer Users Manual not have a Last ID, the tester counts the set as one ID. An ID can have a maximum of 60 characters. Symbols, such as the asterisk, and accented characters do not increment.” on page 78 for more information about the Next ID list. This icon shows when the tester’s link interface adapter is connected to the adapter on a DSX-602 remote and the remote is turned on. The asset management icon shows when the owner of a LinkWare Live account has enabled the asset management service on the tester. See “About the Asset Management Service” on page 90. This icon shows when the talk function is on. To use the talk function: Connect the main and remote testers together through a link that has one or more good wire pairs. Connect headsets to the headset jacks on the testers. Press the button on one of the headset microphones or press on the remote, then speak into the microphone. Make Sure Your Tester is Ready to Certify Cabling To make sure your tester meets its accuracy specifications, follow these guidelines: 28 Keep the tester’s software current. The latest software is available on the Fluke Networks website. See “Update the Software” on page 95. Set the reference for the twisted pair adapters every 30 days. See page 29. Make sure that you select the correct cable type for the job, and that the NVP for the cable is correct. See Table 2 on Chapter 2: Certify Twisted Pair Cabling Set the Reference page 32. Make sure you select the correct test limit for the job. See Table 2 on page 32. Make sure the cords and connectors for all test equipment and patch cords are in good condition. Make sure the battery is fully charged. Send the testers to a Fluke Networks service center every 12 months for factory calibration. Set the Reference The reference procedure for twisted pair cable sets the baseline for insertion loss, ACR-F, and DC resistance measurements. Set the reference at these times: Every 30 days, at minimum. To ensure maximum accuracy of test results, set the reference daily.It is not necessary to set the reference when you change the link interface adapters. To set the reference Turn on the tester and the remote a minimum of 5 minutes before you set the reference. Note Set the reference only after the testers are at an ambient temperature between 50 °F and 104 °F (10 °C and 40 °C). Use the reference patch cord and two channel adapters or permanent link and channel adapters to connect the main and remote testers together as shown in Figure 10. On the home screen, tap TOOLS, then tap Set Reference. On the SET REFERENCE screen tap TEST. 29 DSX-602 CableAnalyzer Users Manual Channel adapters 6 inch (15 cm) reference patch cord Permanent link adapter Channel adapter BK89.EPS Figure 10. Reference Connections for Twisted Pair Cable 30 Chapter 2: Certify Twisted Pair Cabling Settings for Twisted Pair Tests Settings for Twisted Pair Tests Table 2 gives descriptions of the settings for twisted pair tests. To set up a project, which includes the settings in Table 2, cable IDs, and operator names, see Chapter 5. To set up a twisted pair test On the home screen, tap the test setup panel. On the CHANGE TEST screen, select a twisted pair test to change, then tap EDIT. Or to set up a new twisted pair test, tap NEW TEST. On the TEST SETUP screen, tap the panels to change settings for the test. See Table 2. On the TEST SETUP screen, tap SAVE when your test setup is completed. On the CHANGE TEST screen, make sure the button next to the test is selected, then tap USE SELECTED. 31 DSX-602 CableAnalyzer Users Manual Table 2. Settings for Twisted Pair Tests Setting Description Cable Type Select a cable type that is correct for the type you will test. To see a different group of cable types, tap MORE, then tap a group. To make a custom cable type, tap Custom in the Cable Groups list. NVP Nominal velocity of propagation. The tester uses the NVP and the propagation delay to calculate the length of the cable. The default value is defined by the selected cable type and is the typical NVP for that cable type. To enter a or different value, tap the NVP panel, then tap on the NVP screen to increase or decrease the value. To find the actual value for a cable, connect a known length of the cable to the tester, tap MEASURE on the NVP screen, then change the NVP until the measured length matches the known length. Use a cable at least 30 m (100 ft) long. When you increase the NVP value, the calculated length increases. Shield Test This setting shows only when you select a shielded cable type. On: The wire map test includes a DC test for shield continuity and AC tests for shield quality. The wire map test fails if the shield is open or the AC test results are unsatisfactory. Off: The wire map shows the shield if the shield has continuity. The tester does not do AC tests for shield quality. The wire map test does not fail or show the shield if the shield is open. Test Limit 32 Select the correct test limit for the job. To see a different group of limits, tap MORE, then tap the name of a group. Chapter 2: Certify Twisted Pair Cabling Settings for Twisted Pair Tests Table 2. Settings for Twisted Pair Tests (continued) Setting Description Store Plot Data Off : The tester does not save plot data for frequencydomain tests or for the HDTDR/HDTDX analyzers. You can see the plots before you save the test and exit the results screen. The saved results show frequency-domain measurements in a table and do not include the HDTDR/ HDTDX plots. On : The tester saves plot data for all frequencydomain tests required by the selected test limit and for the HDTDR/HDTDX analyzers. HDTDR/HDTDX Fail/Pass* only: The tester shows HDTDR and HDTDX analyzer results only for Autotests with PASS*, FAIL*, or FAIL results. All Autotests: The tester shows HDTDR and HDTDX analyzer results for all Autotests. To get HDTDR/HDTDX analyzer results you can also tap TOOLS > Diagnostics. For more information about the HDTDR and HDTDX analyzers, see the Technical Reference Handbook. Outlet Configuration The Outlet Configuration specifies which wire pairs are tested and which wire numbers the wire map shows for the pairs. See Figure 11. To see the wire map for a configuration, tap Outlet Configuration, tap the configuration name on the OUTLET CONFIG screen, then tap SAMPLE. To select a configuration, tap a name on the OUTLET CONFIG screen, then tap USE SELECTED. Note The OUTLET CONFIG screen shows only the configurations that are applicable to the selected Test Limit. To make a custom outlet configuration, tap CUSTOM on the OUTLET CONFIG screen, then tap MANAGE, then tap Create. 33 DSX-602 CableAnalyzer Users Manual Table 2. Settings for Twisted Pair Tests (continued) Setting AC Wire Map Description The AC Wire Map test lets you do tests on links connected through midspan PoE (Power over Ethernet) devices. See the Technical Reference Handbook. When the AC Wire Map test is on, this icon shows on the home screen: Notes Always turn off the AC wire map test when you will not do tests through a PoE device. The AC wire map test increases the time for an Autotest. It also disables the resistance and shield continuity tests. The DSX-8000 modules do not support the AC wire map test. 34 Chapter 2: Certify Twisted Pair Cabling Settings for Twisted Pair Tests T568A T568B Crossover 1000BASE-T Crossover Rollover 2 x Two-Pair Crossed Ethernet Two-Pair Ethernet Two-Pair Crossed CSU/DSU USOC Two-Pair Token Ring USOC Single-Pair ATM/TP-PMD Straight ATM/TP-PMD Crossed M12 Two-Pair One Pair (1,2) M12 Two-Pair Crossed GPU85.EPS Figure 11. Outlet Configurations 35 DSX-602 CableAnalyzer Users Manual How to Do an Autotest When you tap TEST on the main tester or press on the main or remote tester, the testers do an Autotest. The Autotest includes all the tests necessary to certify that the cabling meets or exceeds the performance requirements specified in the selected test limit. Figure 12 shows the equipment for Autotests on twisted pair cable. BK111.EPS Main and remote testers For tests on permanent links: two permanent link adapters (PRO model or optional) For tests on channels: two channel adapters AC adapters (optional) Figure 12. Equipment for Autotests on Twisted Pair Cable 36 Chapter 2: Certify Twisted Pair Cabling How to Do an Autotest To do an Autotest on twisted pair cable Attach permanent link or channel adapters to the main and remote testers. Make sure that the home screen shows the correct settings for the job. To make sure that other settings are correct, tap the test setup panel, make sure the correct test is selected on the CHANGE TEST SCREEN, then tap EDIT to see more settings. Table 2 on page 32 describes the settings. Connect the testers to the link as shown in Figure 13 or 14. Tap TEST on the main tester or press on the main or remote tester. If the tester at the other end of the cable is in sleep mode or is off, your tester’s tone generator turns on the other tester. If the two testers are not connected: Your tester’s tone generator stays on. Then, you can use a tone probe if necessary to find the cable to connect to the other tester. Or, tap MEASURE to do the tests that do not require a remote tester. Because the tester cannot complete all tests and some tests always fail with no remote connected, the result for an Autotest without a remote is always FAIL. 37 DSX-602 CableAnalyzer Users Manual Horizontal cabling Optional consolidation point Patch panel Wall outlet Start permanent link Tester with permanent link adapter End permanent link Remote with permanent link adapter BK97.EPS Figure 13. Permanent Link Connections 38 Chapter 2: Certify Twisted Pair Cabling “Bad Patch Cord” Message Horizontal cabling Hub or switch Patch cord from hub or switch Optional consolidation point Patch panels Start channel Tester with channel adapter Wall outlet Patch cord from PC End channel Remote with channel adapter BK96.EPS Figure 14. Channel Connections “Bad Patch Cord” Message To comply with standards for tests on channels, the tester removes the effects of the channel adapters and their connections from the test results. Before it removes these effects, the tester makes sure that the plugs on the patch cord do not have too much near-end crosstalk (NEXT). Too much NEXT is frequently caused by too much untwisted wire in the plug. If a plug is bad, the tester shows the message Bad patch cord at main or Bad patch cord at remote, and does not remove the effects of the channel adapters and their connections. The tester saves the message with the results. If you see one of these messages, replace the patch cord or install a new plug at the bad end. 39 DSX-602 CableAnalyzer Users Manual Twisted Pair Autotest Results The tests listed below apply to twisted pair cabling. Note Some tests are not included in some test limits. 40 Wire map Resistance Length Propagation delay Delay skew Insertion loss (attenuation) Impedance NEXT (near-end crosstalk) PS NEXT (power-sum near-end crosstalk) ACR-N (attenuation to crosstalk ratio at the near end) PS ACR-N (power-sum attenuation to crosstalk ratio, near end) ACR-F (attenuation to crosstalk ratio at the far end) PS ACR-F (power-sum attenuation to crosstalk ratio, far end) Return loss HDTDR and HDTDX analyzers (optional tests, not required by any test limit) Chapter 2: Certify Twisted Pair Cabling Twisted Pair Autotest Results PASS*/FAIL* Results A result shows an asterisk when measurements are in the tester’s accuracy uncertainty range (Figure 15) and the asterisk is required by the selected test limit. These results are marginal. A PASS* shows that the cable’s performance is satisfactory. If a cable must get a PASS result to agree with your requirements for quality, identify and correct the problems with the cable and do the Autotest again. Usually, a FAIL* is not a satisfactory result. The tester shows a FAIL for the overall result. Identify and correct the problems with the cable and do the Autotest again. PASS Tester’s accuracy uncertainty range PASS* PASS* FAIL* Limit FAIL GPU87.EPS Figure 15. PASS* and FAIL* Results 41 DSX-602 CableAnalyzer Users Manual WIRE MAP Tab The WIRE MAP tab shows the connections between the ends of the cable under test. The tester compares the connections to the selected Outlet Configuration to get a PASS or FAIL result. If the wire map test fails, you can continue or stop the Autotest. Or, you can tap SCAN ON to do the wire map test continuously while you look for the fault. To continue the Autotest after you correct the fault, tap SCAN OFF, then tap CONTINUE. If you leave then return to the WIRE MAP FAIL screen, the SCAN ON button goes away. To see the button again, tap TEST AGAIN. You can also select the continuous wire map test as a single test from the TOOLS menu. See “Continuous Tests” on page 51. Figure 16 shows an example of a wire map screen. For information on AC wire map screens, see the Technical Reference Handbook. Figure 16. WIRE MAP Tab 42 BA59.EPS Chapter 2: Certify Twisted Pair Cabling Twisted Pair Autotest Results The name of the outlet configuration used for the test. The outlet configuration is a setting on the TEST SETUP screen. The wire map of the cabling. The main tester is at the left side of the wire map. Tap to see information about wire map faults. If shows, tap it to see a message about the results, such as Bad patch cord at remote. The overall result for the Autotest. If the result shows an asterisk, See “PASS*/FAIL* Results” on page 41. The result for the wire map test: The wire map does not agree with the outlet configuration selected for the test. The wire map agrees with the outlet configuration selected for the test. When more than one button shows at the bottom of the screen, the tester highlights one in yellow to recommend which one to tap. See “Buttons to Do Tests and Save Results” on page 20. 43 DSX-602 CableAnalyzer Users Manual PERFORMANCE Tab The PERFORMANCE tab (Figure 17) shows the overall result for each test that is required by the selected test limit. BA86.EPS Figure 17. PERFORMANCE Tab The test limit and cable type used for the test. To see all the settings used for the test, tap the panel. To see detailed results for a test, tap the panel. The overall result for the Autotest. If the result shows an asterisk, See “PASS*/FAIL* Results” on page 41. The overall result for the test: The results exceed the limit. 44 Chapter 2: Certify Twisted Pair Cabling Twisted Pair Autotest Results The results are within the limit. The selected test limit does not have a limit for the test, or a dB rule applies. See the Technical Reference Handbook. The results are within the range of accuracy uncertainty for the tester. See “PASS*/FAIL* Results” on page 41. The measurement shown for frequency-domain results is the worst margin. (The insertion loss plot is different. See the Technical Reference Handbook.) When more than one button shows at the bottom of the screen, the tester highlights one in yellow to recommend which one to tap. See “Buttons to Do Tests and Save Results” on page 20. Frequency-Domain Results Frequency-domain results are the measurements that change with frequency, such as insertion loss and crosstalk. How to Save Frequency-Domain Results as a Plot or a Table If Store Plot Data is on when you do a test, the saved results show as plots. If Store Plot Data is Off, the tester does not save plot data for frequency-domain tests or for the HDTDR/HDTDX analyzers. You can see the plots before you save the test and exit the results screen. Figures 18 and 19 show examples of the two types of screens. Also see “Store Plot Data” on page 33. 45 DSX-602 CableAnalyzer Users Manual BA104.EPS Figure 18. Tabular Results Screen for a Frequency-Domain Test The location where the tester made the measurements. To switch between results for the main and remote, tap REMOTE or MAIN (). The results are for the wire pair or pairs shown. To see the results for a different pair or pairs, tap a tab on the right side of the screen (). WORST MARGIN is the measurement that is nearest to the limit line or exceeds the limit by the largest amount. WORST VALUE is the worst measurement. 46 Chapter 2: Certify Twisted Pair Cabling Twisted Pair Autotest Results The measured value. The limit specified by the selected test limit. MARGIN is the difference between the measured value and the limit. The value is in a red box if the measurement exceeds the limit. To switch between results for the main unit and the remote, tap REMOTE or MAIN. To see the results for a different pair or pairs, tap a tab. The result for the pair. If the result shows an asterisk, see “PASS*/FAIL* Results” on page 41. 47 DSX-602 CableAnalyzer Users Manual HI BA71.EPS Figure 19. Plot Screen for a Frequency-Domain Test The location of the measurements. To switch between results for the main and remote, tap REMOTE or MAIN (). Measured values for the wire pairs. The limit line (in red) for the measurement. Note If the limit line is black, the tester does not evaluate the measurement at those frequencies because a dB rule applies. See the Technical Reference Handbook. 48 Chapter 2: Certify Twisted Pair Cabling Twisted Pair Autotest Results The vertical scale is the measured value in decibels. The horizontal scale is the frequency range in megahertz. To see help for the screen, tap To switch between results for the main unit and the remote, tap REMOTE or MAIN. The margin at the cursor’s location. The margin is the difference between the measured value and the limit. The margin is negative if the pair failed. The measured value at the cursor’s location. When you first look at the plot, the cursor is at the frequency of the worst margin. To move the cursor to the worst value, tap WORST VALUE. (The insertion loss plot is different. See the Technical Reference Handbook.) To see the plots for pairs, tap or . To select pairs to show on the plot, touch or for one second to see the SELECT PAIRS window. Select the pairs you want to see, then tap OK. When you first look at the plot, the cursor is at the frequency of the worst margin. To move the cursor to the worst value, tap WORST VALUE (). The box at the bottom of the cursor shows the frequency at the cursor’s position. To move the cursor to other points, touch and drag the yellow circle at the top of the cursor. To move the cursor in small increments, tap the yellow circle, then tap the arrow buttons that show on the plot ( or ). The overall result for the test. If you look at pairs, the result is for those pairs. If the result shows an asterisk, see “PASS*/ FAIL* Results” on page 41. To zoom in and out, use the pinch, reverse-pinch, and doubletap gestures on the touchscreen. You can also use the zoom controls to change the magnification on the frequency and decibels scales independently. 49 DSX-602 CableAnalyzer Users Manual DIAGNOSTIC Tab If an Autotest on twisted pair cabling fails or has marginal results, the DSX-602 CableAnalyzer automatically gives you HDTDR and HDTDX plots to help you find faults. To see the plots, tap the DIAGNOSTIC tab, then tap the HDTDR or HDTDX panel (Figure 20). To get only diagnostics results, select Diagnostics from the TOOLS menu. These results do not include a PASS/FAIL status. For more information on the HDTDR and HDTDX plots, see the Technical Reference Handbook. BA192.EPS Figure 20. Examples of Diagnostic Screens 50 Chapter 2: Certify Twisted Pair Cabling Twisted Pair Autotest Results Continuous Tests To do the wire map, length, or resistance test continuously, go to the home screen, tap TOOLS > Single Tests, then tap a test. The wire map test compares the results to the outlet configuration specified by the selected test limit and shows the connections agree or if they do not. if The length and resistance tests do not compare the results to a test limit. To save the result, tap SCAN OFF > SAVE. The saved test has an for the overall result. 51 DSX-602 CableAnalyzer Users Manual 52 Chapter 3: Certify Coaxial Cabling The optional DSX-CHA003 coaxial adapters let you use the DSX-600 CableAnalyzer to certify coaxial cabling for network and video applications. Set the Reference for Coaxial Tests To use DSX-CHA003 adapters, you must set the reference for coaxial tests. The reference procedure sets a baseline for insertion loss and resistance measurements. Set the reference at these times: Every 30 days, at minimum. To ensure maximum accuracy of test results, set the reference daily. Note It is not necessary to set the reference again if you use different coaxial adapters. To set the reference Make the connections shown in Figure 21. Turn on the tester and the remote a minimum of 5 minutes before you set the reference. -continued- 53 DSX-602 CableAnalyzer Users Manual Notes Set the reference only after the testers are at an ambient temperature between 10 °C and 40 °C (50 °F and 104 °F). The tester will not let you set the reference if the patch cord is longer than 30 cm (12 in). You can also set the reference with a 50 patch cord On the home screen, select a coaxial cable test. On the home screen, tap TOOLS, then tap Set Reference. On the SET REFERENCE screen tap TEST. 30 cm (12 in) 75 coaxial patch cord Coaxial adapter with F connector adapter DSX-CHA003 COAX ADAPTER DSX-CHA003 COAX ADAPTER Coaxial adapter with F connector adapter BK179.EPS Figure 21. Reference Connections for Tests on Coaxial Cabling 54 Chapter 3: Certify Coaxial Cabling Settings for Coaxial Tests Settings for Coaxial Tests Table 3 gives descriptions of the settings for coaxial tests. To set up a project, which includes the settings in Table 3, cable IDs, and operator names, see Chapter 5. To set up a coaxial test On the home screen, tap the test setup panel. On the CHANGE TEST screen, select a coaxial test to change, then tap EDIT. Or to set up a new coaxial test, tap NEW TEST. On the TEST SETUP screen, tap the panels to change settings for the test. See Table 3. On the TEST SETUP screen, tap SAVE when your test setup is completed. On the CHANGE TEST screen, make sure the button next to the test is selected, then tap USE SELECTED. 55 DSX-602 CableAnalyzer Users Manual Table 3. Settings for Coaxial Tests Setting Description Cable Type Select a cable type that is correct for the type you will test. To see a different group of cable types, tap MORE, then tap a group. To make a custom cable type, tap Custom in the Cable Groups list. NVP Nominal velocity of propagation. The tester uses the NVP and the propagation delay to calculate the length of the cable. The default value is defined by the selected cable type and is the typical NVP for that cable type. To enter a different value, tap the NVP panel, then tap or on the NVP screen to increase or decrease the value. To find the actual value for a cable, connect a known length of the cable to the tester, tap MEASURE on the NVP screen, then change the NVP until the measured length matches the known length. Use a cable at least 30 m (100 ft) long. When you increase the NVP value, the calculated length increases. Test Limit Select the correct test limit for the job. To see a different group of limits, tap MORE, then tap the name of a group. Store Plot Data Off : The tester does not save plot data for insertion loss or for the HDTDR analyzer. You can see the plots before you save the test and exit the results screen. The saved results show insertion loss measurements in a table and do not include the HDTDR plot. On : The tester saves plot data for the insertion loss test and for the HDTDR analyzer. 56 Chapter 3: Certify Coaxial Cabling How to Do an Autotest How to Do an Autotest Figure 22 shows the equipment for tests on coaxial cabling. Notes You can do the HDTDR, length, and resistance tests without a remote tester. See “Tests Without a Remote” on page 62. If you have two main testers, you can use one as a remote. To select the remote function, tap TOOLS > Main as Remote. BK181.EPS Main and remote testers Two DSX-CHA003 adapters For tests on network cabling: F-connector to BNC adapters and patch cords (typically 50 ) For tests on video cabling: F-connector adapters and patch cords (typically 75 ) AC adapters (optional) Figure 22. Equipment for Tests on Coaxial Cabling 57 DSX-602 CableAnalyzer Users Manual To do an Autotest Attach coaxial adapters to the main and remote testers. Make sure that the home screen shows the correct settings for the job. To make sure that other settings are correct, tap the test setup panel, make sure the correct test is selected on the CHANGE TEST screen, then tap EDIT to see more settings. Table 3 on page 56 describes the settings. Connect the testers to the link as shown in Figure 23. WCaution To make sure your results are reliable: Disconnect all taps and devices from the cable. Do not do tests through splitters (See “About Splitters” on page 61). Tap TEST on the main tester or press on the main or remote tester. If the tester at the other end of the cable is in sleep mode or is off, your tester’s tone generator turns on the other tester. If the two testers are not connected: 58 Your tester’s tone generator stays on so you can use a tone probe to find the cable to connect to the other tester. Or, tap MEASURE to do the length and resistance tests, which do not require a remote tester. Because the tester cannot complete all tests, and the reflection at the end of the cable exceeds the 15% limit for the HDTDR test, the result for an Autotest without a remote is always FAIL. Chapter 3: Certify Coaxial Cabling How to Do an Autotest Data network Disconnect all drop cables DSX-CHA003 DSX-CHA003 COAX ADAPTER COAX ADAPTER IP cameras Surveillance network Router Coaxial segment MoCA adapter DSX-CHA003 DSX-CHA003 COAX ADAPTER COAX ADAPTER MoCA adapter Cable TV Note: Do not do tests through splitters. DSX-CHA003 DSX-CHA003 COAX ADAPTER COAX ADAPTER Cable spools DSX-CHA003 COAX ADAPTER BK184.EPS Figure 23. Examples of Connections for Tests on Coaxial Cabling 59 DSX-602 CableAnalyzer Users Manual Coaxial Autotest Results Note Not all test limits include all the tests shown in Figure 24. GPU182.EPS Figure 24. Autotest Results for Coaxial Cabling The test limit and cable type used for the test. To see detailed results for a test, tap the panel. The overall result for the Autotest. If the result shows an asterisk, See “PASS*/FAIL* Results” on page 41. 60 Chapter 3: Certify Coaxial Cabling About Splitters The DIAGNOSTIC tab shows the HDTDR analyzer button, which you can tap to see the HDTDR plot. The plot helps you find faults on the cable. The HDTDR plot for coaxial cable includes limit lines and a PASS/FAIL result. The overall result for the test: The results exceed the limit. The results are within the limit. The selected test limit does not have a limit for the test. The results are within the range of accuracy uncertainty for the tester. See “PASS*/FAIL* Results” on page 41. The measurement shown for the insertion loss plot is the worst value if the test passed, or the worst margin if the test failed. When more than one button shows at the bottom of the screen, the tester highlights one in yellow to recommend which one to tap. See “Buttons to Do Tests and Save Results” on page 20. To do the resistance test continuously, select the test from the TOOLS menu. This function helps you locate intermittent faults. About Splitters If you get these results, there might be a splitter on the cable: The tester cannot find the remote. The tester looses communication with the remote. The test might continue, then loose communication again as the splitter interferes with the communication signal. The length test shows End not found. The resistance test shows an open. The HDTDR plot shows a reflection that has an unusual shape. Because splitters can cause unreliable test results, you should not do tests through them. 61 DSX-602 CableAnalyzer Users Manual Tests Without a Remote You can do the length, resistance, and HDTDR tests without a remote tester. Table 4 describes the effects of a remote on tests. Attach a coaxial adapter to the main tester. Make sure that the home screen shows the correct settings for the job. To make sure that other settings are correct, tap the test setup panel, make sure the correct test is selected on the CHANGE TEST screen, then tap EDIT to see more settings. Table 3 on page 56 describes the settings. Connect the tester as shown in Figure 25. To do an Autotest: Tap TEST on the main tester or press on the main or remote tester. When the MEASURE button shows, tap it to do the length and resistance tests, which do not require a remote tester. To do only the length or resistance test: On the home screen tap TOOLS > Single Tests, then tap a test. To do only the HDTDR test: On the home screen tap TOOLS > Diagnostics, then tap HDTDR. Note Because the tester cannot complete all tests, and the reflection at the end of the cable exceeds the 15% limit for the HDTDR test, the result for an Autotest without a remote is always FAIL. 62 Chapter 3: Certify Coaxial Cabling Tests Without a Remote Table 4. Remote Requirements for Coaxial Tests Test Remote Requirements* HDTDR analyzer Optional. Without a remote, the plot shows large reflections at the end of the cabling. Resistance A remote or a terminator is required for a loop resistance measurement. Length Not required. Because a coaxial cable terminator eliminates signal reflections, the tester cannot measure the length of terminated cabling. The tester shows End not found in this case. Impedance Optional. Without a remote or terminator, the tester cannot measure the impedance of cables longer than 984 ft (300 m). The tester shows Unknown in this case. Propagation delay Not required. Insertion Loss Required. Because a coaxial cable terminator eliminates signal reflections, the tester cannot measure the propagation delay of terminated cabling. In this case, the tester shows End not found. * If a remote is not required for a test, the test runs without activating the toner when no remote is detected. 63 DSX-602 CableAnalyzer Users Manual DSX-CHA003 COAX ADAPTER For length measurements, disconnect terminators. See Table 4 on page 63. DSX-CHA003 COAX ADAPTER BK183.EPS Figure 25. Connections for Coaxial Tests Without a Remote 64 Chapter 3: Certify Coaxial Cabling Continuous Tests Continuous Tests To do the length or resistance test continuously, go to the home screen, tap TOOLS > Single Tests, then tap a test. The length and resistance tests do not compare the results to a test limit. To save the result, tap SCAN OFF > SAVE. The saved test has an for the overall result. 65 DSX-602 CableAnalyzer Users Manual 66 Chapter 4: Manage Test Results View Saved Results On the home screen, tap the RESULTS icon. The RESULTS screen shows the results in the active project. See Figure 26. To view results saved on a USB flash drive, connect the drive, then tap RESULTS, TRANSFER, USB Flash Drive, Import. See “Manage Results on a Flash Drive” on page 72. To organize results and make reports you can give to customers, use LinkWare PC software. 67 DSX-602 CableAnalyzer Users Manual JK Figure 26. RESULTS Screen BA24.EPS The name of the active project. : The number of results that passed. This includes individual results for each ID and tests that have an result. : The number of results that failed. This includes individual results for each ID. 68 Chapter 4: Manage Test Results View Saved Results : The number of DSX CableAnalyzer results that have PASS* results. PASS* results have measurements within the range of accuracy uncertainty for the tester. See “PASS*/FAIL* Results” on page 41. The cable IDs that have FAIL results and must be tested again. The cable IDs that have an overall PASS or result. Tap VIEW ALL to see a summary of the results in all the projects in the tester. TRANSFER lets you export or import results to or from a flash drive and delete results on the flash drive. MANAGE lets you move results to a different project, rename results, or delete results that are in the tester. The scroll bar shows when the list of results is long. To use the scroll bar, tap on the bar or slide your fingertip on the bar. For example, to see the 12th result in the list, tap on “12” in the scroll bar. When you slide your fingertip on the bar, the number of the result you can see is next to your fingertip. Tap the ID/Date control to sort the results by cable ID or by date. When you sort by ID, the results show in ascending order. When you sort by date, the latest result is at the top of the list. These icons show when you connect the tester to a network to use Fluke Networks cloud services (see Chapter 6): The tester is connected to a wireless network. The tester is connected to a wired network. The asset management icon shows when the owner of a LinkWare Live account has enabled the asset management service on the tester. See “About the Asset Management Service” on page 90. 69 DSX-602 CableAnalyzer Users Manual How to Replace a Saved Result that Failed To use the same test settings that were used for the saved result On the home screen, tap the RESULTS icon. On the RESULTS screen, tap a result that failed. Tap TEST AGAIN. When the test is completed, and if Auto Save is on, the tester asks you if you want to overwrite the results. Tap Yes. If Auto Save is off, tap FIX LATER (if the test failed) or SAVE (if the test passed) to save the result. To replace a result with a result that uses different test settings Turn off Auto Save. Make sure that the home screen shows the project that contains the result you want to replace. Select the necessary test settings. Do the test, tap FIX LATER (if the test failed) or SAVE (if the test passed), then enter the ID of the saved result. The tester asks you if you want to overwrite the results. Tap Yes. Delete, Rename, and Move Results Before you delete, rename, or move results, select the project that contains the results and go to the MANAGE RESULTS screen: 70 On the home screen, tap the RESULTS icon. The RESULTS screen shows the results in the active project. To see the results in another project, tap VIEW ALL, then tap a project. Tap MANAGE to see the MANAGE RESULTS screen. Chapter 4: Manage Test Results Delete, Rename, and Move Results To delete results On the MANAGE RESULTS screen, select the results you want to delete. To select all the tests that failed or all the tests that passed, tap Select All Retests or Select All Passes. Tap DELETE, then tap DELETE in the confirmation dialog. To rename results On the MANAGE RESULTS screen, select one result to rename. Tap RENAME. Enter a new name, then tap DONE. To move results to a different project On the MANAGE RESULTS screen, select the results you want to move. Tap MOVE. To move the results to a project shown in the list, tap the project name, then tap MOVE in the confirmation dialog. To make a new project and move the results to the new project, tap NEW PROJECT, enter a project name, tap DONE, then tap MOVE in the confirmation dialog. Note When you move results to a different project, that project becomes the active project. 71 DSX-602 CableAnalyzer Users Manual Manage Results on a Flash Drive You can export or import results to or from a flash drive, and delete results on the flash drive. To export or import project settings along with results, see “Manage Projects on a Flash Drive” on page 81. WCaution Do not remove the USB flash drive while the LED on the drive flashes. Doing so can corrupt the data on the drive. You can lose a USB flash drive, cause damage to it, or accidentally erase the contents of the drive. Thus, Fluke Networks recommends that you save no more than one day of test results on a flash drive. Note The tester reads only USB drives that use the FAT format. Connect a USB flash drive to the type A USB port. The tester makes a bell sound when it detects the drive. On the home screen, tap the RESULTS icon, then tap TRANSFER. On the TRANSFER RESULTS screen, tap USB Flash Drive, then tap a function: Export: On the EXPORT RESULTS screen, select New or All, select the project that contains the results you want to export to the flash drive, then tap EXPORT. New: Export only results that do not have the same IDs as results that are already on the flash drive. All: Export all the results from all projects in the tester. Note Cable IDs are case-sensitive. For example, the tester saves result with the names “A0” and “a0” in two different records. 72 Chapter 4: Manage Test Results Upload Results to a PC Import: On the IMPORT RESULTS screen select the project that contains the results you want to import from the flash drive, then tap IMPORT. Delete: On the DELETE RESULTS screen select the project that contains the results you want to delete on the flash drive, then tap DELETE. Upload Results to a PC Note To upload results to the cloud for transfer to a PC, use the LinkWare Live web application. See Chapter 6. To upload results to a PC from the tester or a flash drive, use LinkWare PC software. Install the latest version of LinkWare PC software on the PC. Turn on the tester and start LinkWare PC on the PC. Use the USB cable supplied to connect the Micro-AB USB port on the tester to a type A USB port on the PC. See Figure 27. Or connect a USB flash drive to the PC. On the LinkWare PC toolbar, click , then select a product, or select Test Files (.tst) to upload from a flash drive. In the Import dialog box in LinkWare PC, select options for the location and the number of results to import. 73 DSX-602 CableAnalyzer Users Manual AC adapter Type A USB port Micro-AB USB port Figure 27. How to Connect the Tester to a PC BK46.EPS View the Memory Status To see the memory status On the home screen, tap the TOOLS icon, then tap Memory Status. The MEMORY STATUS screen shows these values: 74 The percentage of memory available The number of test records that are saved The number of .id files that have been downloaded to the tester from LinkWare PC software The memory space taken by other files, such as the databases for projects and test limits Chapter 5: Use Projects Why Use Projects? The tester’s ProjX™ management system lets you set up projects that help you monitor the status of a job and make sure that your work agrees with the requirements of the job. You can use a project to do these tasks: Specify the tests that are necessary for a job. Specify settings for tests. Specify an operator for the job. Make sets of sequential IDs to use as names for test results. Automatically save test results with IDs from a set. Add the results from other necessary tests to each saved result in the project. See which IDs do not have results for a specified test. See what percentage of a job is completed. See how many links passed and how many failed. Keep the test results from a job in one place for easy access. When you use a project, you can do tests and use IDs that are not specified in the project if necessary. You can also easily change the settings in a project if necessary. Note To manage projects in the cloud, use the LinkWare Live web application. See Chapter 6. 75 DSX-602 CableAnalyzer Users Manual Set Up a Project Refer to the PROJECT screen in Figure 28 on page 77. On the home screen, tap the PROJECT panel, tap CHANGE PROJECT, then tap NEW PROJECT. On the NEW PROJECT screen, enter a name for the project, then tap DONE. On the PROJECT screen, tap the Operator panel to enter an operator name for the project. On the PROJECT screen, tap the NEW TEST button to enter the tests and test settings necessary for the project. On the PROJECT screen, tap the NEW ID SET button to make one or more sets of cable IDs for the project. See the CABLE ID SETUP screen in Figure 29 on page 79. On the PROJECT screen, tap DONE. The PROJECT Screen To start a new project, tap the PROJECT panel on the screen. Figure 28 shows the PROJECT screen and describes the items you enter to make a project. The name of the project. See also item . Operator: The name of the person who will do the tests for the project. For each operator you can also enter the email address that the operator will use as an ID to sign in to LinkWare Live. The date range for the results in the project. Results: A summary of the test results in the project: : The number of tests that failed. : The number of tests that passed. 76 Chapter 5: Use Projects The PROJECT Screen Figure 28. PROJECT Screen GPU08.EPS : The number of DSX CableAnalyzer results that have PASS* results. PASS* results have measurements within the range of accuracy uncertainty for the tester. See “PASS*/FAIL* Results” on page 41. Test Setup: The tests that are available in the project. To add a test to the project, tap NEW TEST. Cable ID Sets: The sets of IDs the tester can use for the names of test results. To add a set of IDs to the project, tap NEW ID SET. See Figure 29. 77 DSX-602 CableAnalyzer Users Manual To use a different project, tap CHANGE PROJECT, then tap a project. To make a new project, tap CHANGE PROJECT, then tap NEW PROJECT. TRANSFER lets you export or import projects to or from a flash drive and delete projects on the flash drive. The project data includes all project settings and test results. MANAGE lets you rename, copy, or delete a project that is in the tester. To delete the test setup or ID set, tap . To copy the test setup or ID set so you can edit it to make a new one, tap Notes If you delete an imported ID set from a project, the ID set is still available in the tester. To delete imported ID sets from the tester, use LinkWare PC software. A project must have at least one Test Setup and one Cable ID set. If you delete them all, the tester makes a default Test Setup and Cable ID set. The CABLE ID SETUP Screen To see the CABLE ID SETUP screen, tap the PROJECT panel on the home screen, then tap NEW ID SET on the PROJECT screen. See Figure 29. Each project can have up to 5000 IDs. If an ID set does not have a Last ID, the tester counts the set as one ID. An ID can have a maximum of 60 characters. Symbols, such as the asterisk, and accented characters do not increment. 78 Chapter 5: Use Projects The CABLE ID SETUP Screen Figure 29. CABLE ID SETUP Screen (after you enter the first and last IDs) BA09.EPS First ID and Last ID: The first and last IDs in a set of sequential IDs. If you do not enter a Last ID when you make an ID set, the tester will increment the First ID to make subsequent IDs. Note The tester does not increment symbols or accented characters. When you use an ID set that does not have a Last ID, the set under IDs Untested on the CHANGE ID screen shows only the next ID. 79 DSX-602 CableAnalyzer Users Manual Total IDs: The number of IDs in the set. This section does not show for ID sets that do not have a Last ID. Tap IMPORT to use an ID set that you downloaded to the tester from LinkWare PC software. Tap REVIEW to see the CABLE ID REVIEW screen, which shows the ID set an the total number of IDs. Note The REVIEW button does not show if you do not enter a Last ID. SAVE: To save the ID set, tap SAVE. About Next ID Sets If you do not enter a Last ID when you make an ID set, the tester uses the First ID as the Next ID. The tester increments the Next ID each time you save a result. Numbers increment sequentially: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, ... 99, 100, 101... Letters increment through the English alphabet: A, B, C, D, ... Z, AA, AB, AC, AD, ... AZ, BA, BB, BC... Numbers and letters do not cause each other to increment: 1Y, 1Z, 1AA, 1AB, ... 1ZZ, 1AAA, 1AAB... The tester does not increment symbols or accented characters. When you use a Next ID set, the set under IDs Untested on the CHANGE ID screen shows only the next ID. To save the next test with a different ID, tap the Next ID: panel, then enter a different ID. Each project can have one Next ID set. If your project has only a Next ID set, the tester cannot calculate the percentage of the project that is completed, so the % Tested value does not show on the home screen. 80 Chapter 5: Use Projects Manage Projects on a Flash Drive If your project has both a Next ID set and sets with first and last IDs, the % Tested value includes tests you saved with Next ID. For example, if you have one Next ID set and one set with 10 IDs, and you save 10 results with next IDs, the % Tested shows 50% (10 saved results divided by 20 IDs). Manage Projects on a Flash Drive You can export or import projects to or from a flash drive, and delete projects on the flash drive. The project data includes all project settings, test results, and ID sets. WCaution Do not remove the USB flash drive while the LED on the drive flashes. Doing so can corrupt the data on the drive. You can lose a USB flash drive, cause damage to it, or accidentally erase the contents of the drive. Thus, Fluke Networks recommends that you save no more than one day of test results on a flash drive. Note The tester reads only USB drives that use the FAT format. Connect a USB flash drive to the type A USB port. The tester makes a bell sound when it detects the drive. On the home screen, tap the PROJECT panel. On the PROJECT screen, tap TRANSFER. On the TRANSFER PROJECTS screen, select a function: Export: On the EXPORT PROJECTS screen, select the projects you want to export to the flash drive, then tap EXPORT. -continued- 81 DSX-602 CableAnalyzer Users Manual Import: On the IMPORT PROJECTS screen select the projects you want to import from the flash drive, then tap IMPORT. Delete: On the DELETE PROJECTS screen select the projects you want to delete on the flash drive, then tap DELETE. Copy Project Settings to Other Testers To copy the settings in a project to other DSX-602 testers, use the Read Project Setups and Write Project Setups utilities in LinkWare PC software. You can use LinkWare PC to read project settings from a tester or from a project you exported to a flash drive. 82 Chapter 6: Sync Projects with LinkWare™ Live The LinkWare Live web application lets you manage your projects from a desktop or mobile device. Sign Up for a LinkWare Live Account Go to www.linkwarelive.com/signin. If you already have a LinkWare Live account, enter your email address and password on the LinkWare Live Sign In page. If you do not have a LinkWare Live account, click New user? Sign up now!. Enter the information for your account, then click CREATE ACCOUNT. Fluke Networks sends you an email with a LinkWare Live activation code. Open the email, copy the activation code, click the LinkWare Live activation link in the email, paste the activation code into the box in the activation window, then click ACTIVATE. The LinkWare Live Sign In page shows again. Enter your email address and password, then click SIGN IN. 83 DSX-602 CableAnalyzer Users Manual How to See the Tester’s MAC Address Some networks require users to register their device’s MAC address before they can connect to the network. There are two MAC addresses: one for the wired port and one for the Wi-Fi adapter. To see the tester’s or Wi-Fi adapter’s MAC address On the home screen tap TOOLS, then tap Network. On the NETWORK screen, tap the Wired or Wi-Fi panel. The MAC addresses shows at the top of the WIRED and WI-FI PORT screens. Use LinkWare Live Through a Wired Ethernet Network Use an appropriate cable to connect the tester’s RJ45 Ethernet port to an active network port. If the cable is good and the port is active, the LEDs on the tester’s port will come on. On the home screen, make sure the Operator name is correct. The tester uses the email address associated with the operator name as the ID when you sign in to LinkWare Live. If no address is associated with the name, or if you enter a different address on the LWL SIGN IN screen, the tester associates the name with the address you enter. 84 On the home screen, tap the SYNC icon. When the tester connects to the network, the wired network connection icon shows at the top of the screen: On the LWL SIGN IN screen, if necessary, enter the ID and password for your LinkWare Live account, then tap SIGN IN. If you use other people’s LinkWare Live accounts, the ORGANIZATION screen shows. Tap the organization you want to use. Chapter 6: Sync Projects with LinkWare™ Live Use LinkWare Live Through a Wi-Fi Ethernet Network On the SYNC PROJECTS screen (Figure 30 on page 86), select the projects you want to sync, then tap SYNC. Use LinkWare Live Through a Wi-Fi Ethernet Network The tester can use wireless network channels 1 through 11. To connect the tester to a Wi-Fi network On the home screen, make sure the Operator name is correct. The tester uses the email address associated with the operator name as the ID when you sign in to LinkWare Live. If no address is associated with the name, or if you enter a different address on the LWL SIGN IN screen, the tester associates the name with the address you enter. On the home screen, tap the SYNC icon. Select a wireless network if necessary. If the network setting are not correct, the tester shows the NETWORK screen and a message about the necessary settings. a. To change the settings, tap the Wi-Fi panel. b. To test the settings, go back to the WI-FI PORT screen, then tap CONNECT. When the tester connects to the network, the Wi-Fi network connection icon shows at the top of the screen: c. Go back to the TRANSFER RESULTS screen, then tap the LinkWare Live panel. On the LWL SIGN IN screen, if necessary, enter the ID and password for your LinkWare Live account, then tap SIGN IN. Enter a user name and password for the network, if necessary. -continued- 85 DSX-602 CableAnalyzer Users Manual If you use other people’s LinkWare Live accounts, the ORGANIZATION screen shows. Tap the organization you want to use. On the SYNC PROJECTS screen (Figure 30), select the projects you want to sync, then tap SYNC. See Figure 30: Projects in the On this tester section are possibly also in LinkWare Live. You can upload results from these projects to LinkWare Live. If the project in LinkWare Live has test settings or cable IDs that are different from those in the tester, you can download the new settings to the tester. Figure 30. SYNC PROJECTS Screen 86 GPU190.EPS Chapter 6: Sync Projects with LinkWare™ Live Use LinkWare Live Through a Wi-Fi Ethernet Network By default, the active project is selected to sync. Projects in the Available only on LinkWare Live section have project settings you can download to the tester. If you download these projects, only test settings and cable IDs are downloaded. Any test results saved in the project in LinkWare Live are not downloaded. If you select Assigned to me only, you will see only projects that are assigned to you in the project settings in LinkWare Live. 87 DSX-602 CableAnalyzer Users Manual Change the Network Settings It is not usually necessary to change the wired or Wi-Fi network settings before you try to make a connection. But for example if you must use static addressing, you can get to the settings on the NETWORK screen. To get to the network settings On the home screen, tap TOOLS, then tap Network, then tap the Wired or Wi-Fi panel. To test the settings Tap CONNECT on the WI-FI PORT or WIRED PORT screen. Settings for the Wired Port The tester can use DHCP (dynamic host configuration protocol) or Static for the address method. Most networks use DHCP. For Static, enter an IP address for the tester and the Subnet Mask, Gateway address, and DNS1 and DNS2 addresses for the network. If you are not sure what to enter, speak to the network administrator. Settings for the Wi-Fi Port Table 5 shows the Wi-Fi settings. 88 Chapter 6: Sync Projects with LinkWare™ Live Change the Network Settings Table 5. Settings for the Wi-Fi Connection Setting Description Address Most networks use DHCP. DHCP address settings SSID: The tester does a scan for wireless networks and shows a list of available networks. Select the correct SSID. To connect to a hidden network, tap ADD SSID. Security: Authentication: Select the authentication type that the network uses: Open: Security credentials are not necessary. WEP: Select an encryption method and enter the necessary keys. WPA/WPA2 Personal: Enter the password for the network. WPA/WPA2 Enterprise: EAP: Select an EAP type that is appropriate for the authentication server. User and Password: Enter a user name (login name) and password for the network. Alternate ID: The tester can use the Alternate ID with some EAP methods to send an empty or anonymous identity while the tester makes a private connection. The tester then uses the private connection to send the User name and Password you entered. The tester can also use the Alternate ID to send the User name and Password to an authentication server in a different realm. In this situation, the Alternate ID can have a format such as anonymous@MyCompany.com or /MyCompany/ anonymous. 89 DSX-602 CableAnalyzer Users Manual Table 5. Settings for the Wi-Fi Connection (continued) Setting Description Static address settings Enter an IP address for the tester and the Subnet Mask, Gateway address, and DNS1 and DNS2 addresses for the network. If you are not sure what to enter, speak to the network administrator. The Security settings are the same as for the DHCP address settings. Delete Wi-Fi Settings and Passwords The tester saves the security settings and passwords for the Wi-Fi connections you use. To delete all Wi-Fi settings and passwords On the home screen, tap TOOLS, then tap Network, tap the Wi-Fi panel, then tap FORGET ALL. About the Asset Management Service LinkWare Live’s asset management service lets you see the locations of your DSX-602 testers in the field. The owner of the LinkWare Live account can enable or disable the service remotely for each DSX-602 tester. When this service is enabled on a DSX-602 tester, the asset management icon ( ) shows on the tester’s home screen. When a technician uses the tester to sign in to LinkWare Live, the tester’s location shows on a map on LinkWare Live’s ASSETS page. Note You can enable or disable the asset management service only with LinkWare Live. There is no setting on the DSX-602 tester that enables or disables this service. 90 Chapter 6: Sync Projects with LinkWare™ Live Sign Your Tester Out of LinkWare Live Sign Your Tester Out of LinkWare Live On the home screen, tap the TOOLS icon, then tap Sign In. On the LWL SIGN IN screen, tap SIGN OUT. Or, turn off the tester. Sign In to LinkWare Live from a Desktop or Mobile Device Go to https://www.linkwarelive.com/signin. Enter your LinkWare Live user name and password, then click SIGN IN. For more information about how to use LinkWare Live, click HELP on the LinkWare Live web page. Import Projects from LinkWare Live into LinkWare PC Install the latest version of LinkWare PC software on the PC. Turn on the tester and start LinkWare PC on the PC. Use the USB cable supplied to connect the Micro-AB USB port on the tester to a type A USB port on the PC. On the LinkWare PC toolbar, click Sign in to your LinkWare Live account, then use the LinkWare PC dialog boxes to select and import projects. Learn More About LinkWare Live Go to http://www.flukenetworks.com/linkwarelive. 91 DSX-602 CableAnalyzer Users Manual 92 Chapter 7: Maintenance WWarningX To prevent possible fire, electric shock, personal injury, or damage to the tester: Do not open the case. You cannot repair or replace parts in the case. Use only replacement parts that are approved by Fluke Networks. If you replace parts that are not specified as replacement parts, the warranty will not apply to the product and you can make the product dangerous to use. Use only service centers that are approved by Fluke Networks. WCaution If you replace electrical parts yourself, the tester will possibly not have the correct calibration and can give incorrect test results. If the calibration is not correct, cable manufacturers can remove their warranty from the cabling you install. 93 DSX-602 CableAnalyzer Users Manual Verify Operation The tester does a self test when you turn it on. If the tester shows an error or does not turn on, refer to “If the Tester Does Not Operate as Usual” on page 102. Clean the Tester To clean the touchscreen, turn off the tester, then use a soft, lintfree cloth that is moist with water or water and a mild detergent. To clean the case, use a soft cloth that is moist with water or water and a mild detergent. WWarningX Do not put the tester or the battery pack in water. WCaution To prevent damage to the touchscreen or the case, do not use solvents or abrasive materials. When you clean the touchscreen or the case, do not let liquid get under the plastic around the touchscreen. 94 Chapter 7: Maintenance See Information About the Tester See Information About the Tester To see information about your tester On the home screen, tap the TOOLS icon, then tap Version Information. To see information about your remote tester Connect the main and remote testers together (see Figure 6 on page 17), then tap REMOTE on the Version Information screen. Update the Software New software gives you access to new features and the latest test limits and cable types. Software updates are available on the Fluke Networks website. You can use a PC to install a software update, or connect an updated main unit to a remote or to another main unit to update those units. You can also use LinkWare Live to download a software update from the cloud to your main tester, then use the main tester and a USB cable to install the update in the remote. 95 DSX-602 CableAnalyzer Users Manual Use a PC to Update the Software WCaution To prevent unexpected loss of power, connect the ac adapter to the tester when you update the software. Note The software update procedure does not delete the test records, project settings, or user preferences in the tester, but can possibly change the factory-installed cable types or test limits. Install the latest version of LinkWare PC software on your PC. LinkWare PC is available on the Fluke Networks website. Connect the AC adapter to the tester and connect the Micro-AB USB port on the tester to a type A USB port on the PC. See Figure 31. LinkWare PC automatically tells you if new software for the tester is available on the Fluke Networks website, and lets you install the software. Note Older versions of LinkWare PC do not start the update procedure automatically. For older versions, you must have the software update file on a disk or USB drive and click to start the update procedure. 96 The tester reboots when the update is completed. To make sure the update was installed correctly, tap the TOOLS icon on the home screen, tap Version Information, then make sure the correct version shows. Do steps 2 through 4 again for the remote. On a remote tester, the LEDs show the progress of the installation. Chapter 7: Maintenance Update the Software AC adapter Type A USB port Micro-AB USB port Figure 31. How to Connect the Tester to a PC BK46.EPS Use an Updated Main Tester to Update Other Testers Turn on both testers and connect the AC adapters to both testers. Use the USB cable provided to connect the updated main unit to the remote or to another main. See Figure 32. Follow the instructions shown on the display of the updated main unit. Note If a remote has newer software than the main unit, the main unit can install the older software in the remote so that you can use the two units together. The remote cannot install the newer software in the main unit. 97 DSX-602 CableAnalyzer Users Manual AC adapters Remote Updated main unit Type A USB port Micro-AB USB port AC adapters Main unit Updated main unit Type A USB port Micro-AB USB port BK116.EPS Figure 32. How to Connect Units Together to Update the Software 98 Chapter 7: Maintenance Update the Software Use LinkWare Live to Update the Software Use an appropriate cable to connect the tester’s RJ45 Ethernet port to a network port, or connect a Wi-Fi adapter to the tester’s type A USB port. On the home screen, tap the SYNC icon. For a wireless network, if the network selection screen shows, connect to a network: a. Select a network. b. Enter security information. c. Go back to the previous screen, then tap CONNECT. d. Go back to the home screen, then tap SYNC. On the LWL SIGN IN screen, enter the ID and password for your LinkWare Live account, then tap SIGN IN. If a software update is available, the tester shows a message. Tap YES to install new software in your tester. The tester reboots when the update is completed. To install the update in a remote or another main tester, use the USB cable provided to connect the updated main tester to the other tester. See Figure 32. Follow the instructions shown on the display of the updated main tester. 99 DSX-602 CableAnalyzer Users Manual Extend the Life of the Battery WWarningX To prevent possible fire, electric shock, or personal injury, read the warnings about the rechargeable battery under “WarningX” on page 4. Do not frequently let the battery discharge completely. Do not keep the battery at temperatures below -20 oC (-4 oF) or above +50 oC (+122 oF) for periods longer than one week. Before you put a battery into storage, charge it to approximately 50 % of full charge. Store the Tester Before you store a tester or an extra battery for a long period, charge the battery to approximately 50 % of full charge. The discharge rate of the battery is 5 % to 10 % each month. Check the battery every 4 months and charge it if necessary. Keep a battery attached to the tester during storage. If you remove the battery for more than approximately 24 hours, the tester will not keep the correct time and date. Storage temperature: -22 °F to +140 °F (-30 °C to +60 °C) Remove the Battery Figure 33 shows how to remove the battery. Notes If you remove the battery and do not connect the AC adapter, the clock keeps the current date and time for a minimum of 24 hours. The screw does not come out of the battery door. 100 Chapter 7: Maintenance Traceable Calibration Period OFF Model VERSIV-BATTERY BA21.EPS Figure 33. How to Remove the Battery Traceable Calibration Period To make sure that the testers operate within the published specifications for accuracy, have them calibrated at a Fluke Networks authorized service center every 12 months. To get information on factory calibration, contact an authorized Fluke Networks Service Center. To see when the tester last received a factory calibration, tap the TOOLS icon on the home screen, then tap Version Information. Options and Accessories For a complete list of options and accessories go to the Fluke Networks website at www.flukenetworks.com. To order options and accessories, contact an authorized Fluke Networks distributor. 101 DSX-602 CableAnalyzer Users Manual If the Tester Does Not Operate as Usual If the tester does not operate as usual or if it shows an unusual message, see Table 6 for possible explanations and solutions to some conditions that can occur. If the condition continues, contact Fluke Networks for assistance, or search the Fluke Networks Knowledge Base for a solution. If you contact Fluke Networks, have available the serial number, software and hardware versions, and calibration date for the tester, if possible. To see this information, tap the TOOLS icon on the home screen, then tap Version Information. You can also use LinkWare PC software to upload the system log from the tester. This file contains information that can possibly help Fluke Networks find a solution to an unusual problem. The serial numbers of the main and remote units are on a sticker on the back of the units. Table 6. Possible Solutions for Unusual Behavior The touchscreen or the keys do not respond. Press and hold until the tester turns off. Then turn on the tester. If the problem continues, install the latest version of software in the tester. The tester will not turn on even though the battery is charged. The safety switch or the fuse in the battery is possibly open. Wait a few seconds, then try again. If the tester does not turn on, the battery is possibly bad and must be replaced. The tester can operate on AC power if the battery does not operate. Test results appear to be incorrect. The tester possibly has incorrect settings. Make sure you selected the correct cable type and test limit. 102
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : tamis Create Date : 2017:05:08 13:22:16Z Modify Date : 2017:09:11 15:41:41+08:00 Language : en Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Creator : tamis Title : Man_Users_DSX-600_us.book Creator Tool : FrameMaker 12.0.4 Metadata Date : 2017:09:11 15:41:41+08:00 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:deccf015-d3e0-4388-83e7-88b5a3105856 Instance ID : uuid:7db642ee-c6ad-4062-973b-eb256d1680d2 Page Mode : UseOutlines Page Count : 110EXIF Metadata provided by EXIF.tools