Follet 160002 Quick Start Guide 00160002R09_Cond
2014-07-05
: Follet Follet-160002-Quick-Start-Guide follet-160002-quick-start-guide follet pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Horizon™ Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1000R _ _ HCD/HMD/HCF/HMF1400R _ _ HCD/HMD/HCF/HMF1650R _ _ (See model number configurator on page 2 for details.) Order parts online www.follettice.com remote condensing unit a Pennsylvani NO Easton PART SINGLE PHASE OZ HZ N NO SERIAL CORPORATIO PSIG VOLTS PROTECTED CHARGE SIDE LOW R THERMALLY MODEL AMPS MOTOR T REFRIGERAN PRESSURE HIGH IN MADE USA THE NSF UL COMPRESSO LOAD FULL R UL C R SIDE AMPS AMPS AMPACITY DESIGN CIRCUIT SIZE FUSE BRANCH MIN. CIRCUIT BRANCH 208264 MAX. Stock Module Identification Plate Module No. Product Service No. NO PART SINGLE PHASE OZ HZ PSIG CHARGE SIDE LOW MODEL IN MADE USA THE NSF UL R UL C R AMPS AMPS 208264 Stock Module Identification Plate Module No. Product Service No. Pennsylvania NO Easton PART SINGLE PHASE OZ HZ NO SERIAL CORPORATION PSIG VOLTS PROTECTED CHARGE SIDE LOW THERMALLY MODEL AMPS C R SIDE HIGH IN MADE USA THE R UL MOTOR REFRIGERANT PRESSURE NSF UL COMPRESSOR LOAD FULL AMPS AMPS AMPACITY DESIGN CIRCUIT SIZE FUSE BRANCH MIN. CIRCUIT BRANCH 208264 MAX. Stock Module Identification Plate Module No. Product Service No. Drop-in Remote Condensing RIDE™ remote ice delivery equipment Harmony Remote Condensing Top Mount Bin Remote Condensing Top Mount NO PART SINGLE PHASE OZ HZ PSIG CHARGE SIDE IN MADE USA THE LOW MODEL NSF UL R UL C R AMPS AMPS 208264 Stock Module Identification Plate Module No. Product Service No. NO PART SINGLE PHASE OZ HZ PSIG CHARGE SIDE LOW MODEL IN MADE USA THE NSF UL R UL C R AMPS AMPS 208264 Stock Module Identification Plate Module No. Product Service No. Pennsylvania NO Easton PART SINGLE PHASE OZ HZ NO SERIAL CORPORATION PSIG VOLTS PROTECTED CHARGE SIDE LOW THERMALLY MODEL AMPS C R SIDE HIGH IN MADE USA THE R UL MOTOR REFRIGERANT PRESSURE NSF UL COMPRESSOR LOAD FULL AMPS AMPS AMPACITY DESIGN CIRCUIT SIZE FUSE BRANCH MIN. CIRCUIT BRANCH 208264 MAX. Stock Module Identification Plate Module No. Product Service No. Vision™ Remote Condensing RIDE remote ice delivery equipment Harmony™ Remote Condensing RIDE remote ice delivery equipment 801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com Bin Remote Condensing RIDE remote ice delivery equipment 00160002R09 Read and complete the following 8 installation steps Unpack Site preparation 1 2 Condenser installation Refrigeration line assembly 3 4 Pressure adjustment Startup and test 5 6 Chewblet® Ice Machine Model Number Configurations HC Icemaker MC Maestro™ Chewblet® (400 Series) HC Horizon Chewblet (1000, 1400, 1650 Series) HM Horizon Micro Chewblet 2 Voltage C 1400 A Series 400 up to C 208-230/60/1 (icemaking head) Self-contained only. 454 lbs D 115/60/1 (icemaking head) (206kg) Self-contained and remote. If remote 1000 up to unit, high side is 208-230/60/1. 1036 lbs E 230/50/1 (icemaking head) (471kg) Self-contained only. 1400 up to F 115/60/1 (icemaking head) 1450 lbs Remote only. High side is (658kg) 208-230/60/3. V S Condenser A W R N Air-cooled, self-contained Water-cooled, self-contained Air-cooled, remote condensing unit Air-cooled, no condensing unit for connection to parallel rack system V H B J M Application Configuration Vision™ Harmony™ Ice storage bin Drop-in Ice Manager diverter valve system S RIDE™ (RIDE remote ice delivery equipment) T Top-mount 1650 up to 1580 lbs (717kg) REMOTE CONDENSING UNIT Unpack 1 Site preparation 2 Carefully unpack and inspect the contents of your condensing unit To ensure proper performance, ease of service and warranty coverage, it is critical that you follow the requirements detailed in this manual. If you cannot meet these requirements or have questions, call our technical service group at 877.612.5086 for installation support. 2.1 2.1 Condenser Unit Clearances 38" (965mm) (only required for Single-phase units) B 48" (1219mm) 48" (1219mm) A Discharge air Air flow 48" (1219mm) (only required for Single-phase units) Single-phase 3-phase A 27.0 (68.6 cm) 23.50” (59.7 cm) B 38.9 (98.8 cm) 35.13” (89.2 cm) • Position condenser unit as shown above, with clearances noted above REMOTE CONDENSING UNIT 3 2.1 2.2 Condenser installation specifications 100' max. (30,5m) ➍ CONDENSER UNIT maximum line rise ➋ S-trap required ➊ +35' (+10,7m) CONDENSER UNIT +20' (+6,1m) P-trap required +3' (+0,9m) Easton Pennsylvania CORPORATION MODEL PART NO SERIAL NO FULL LOAD AMPS VOLTS HZ SINGLE PHASE MOTOR COMPRESSOR THERMALLY PROTECTED REFRIGERANT CHARGE DESIGN PRESSURE HIGH SIDE OZ LOW SIDE PSIG 208264 Stock Module Identification Plate Module No. Product MIN. BRANCH CIRCUIT AMPACITY AMPS MAX. BRANCH CIRCUIT FUSE SIZE AMPS UL UL R R NSF MADE IN THE USA C Service No. EVAPORATOR UNIT EVAPORATOR UNIT LEVEL CONDENSER UNIT –15' (–4,6m) maximum line drop 100' max. (30,5m) ➌ ➍ Site layout: • Outdoor ambient temperature range: –20 F to 120 F (–29 C to 49 C) • Installation with condenser unit elevations above 20' (6,1m) require an S-trap at the midpoint of the rise ➊ • Maximum line rise must not exceed 35' (10,7m) ➋ • Maximum line set length must not exceed 100' (30,5m) ➌ • Maximum line drop must not exceed 15' (4,6m) ➍ Note: The service loop is not included when calculating the length, rise or drop of the tubing run. Note: 1400/1650 units only: HCD1400/1650 condensing units contain a liquid to suction line heat exchanger. To maintain optimum liquid refrigerant sub-cooling from the heat exchanger, the entire liquid line should be insulated separately from the suction line. 4 REMOTE CONDENSING UNIT Condenser installation 3.1 Install condensing unit 3.2 3 Electrical connections Horizon Remote Single-Phase • 208-230/60/1 1000 - 15 amp circuit 1400 - 30 amp circuit 1650 - 50 amp circuit Horizon Remote 3-Phase • 208-230/60/3 1000 - 15 amp circuit 1400 - 25 amp circuit 1650 - 35 amp circuit • Refer to wiring schematic located in condenser unit electrical box • Level unit • Securely attach base of unit using holes found in base plate REMOTE CONDENSING UNIT CAUTION • Electrical disconnects required within 10' (3m) for all hard wired connections • Install in accordance with NEC and local electrical codes 5 Refrigeration line installation 4.1 4 Refrigeration line installation: 7/8" suction / 3/8" liquid line (1650) 5/8" suction / 3/8" liquid line (1000, 1400) CAUTION • The installer of the refrigeration line set must be USA Government Environmental Protection Agency (EPA) certified in proper refrigeration handling and service procedures • A qualified person must perform all roof or wall penetration • Do not form unwanted traps in refrigeration lines. A service loop is not considered an oil trap. • Never coil excess refrigeration tubing • The compressor oil rapidly absorbs moisture. Minimize the exposure of the refrigeration system by not releasing the condenser unit or evaporator unit holding charge until all line connections are finished and the system is ready for evacuation. • It is recommended that both liquid and suction lines are run and insulated together for the first 15 feet (4,6m) from the condensing unit. This protects the system from sub-cooling loss and/or liquid slugging the compressor. WARNING • This unit contains an R404A holding charge 1. Make and connect line set run from the condensing unit to the evaporator unit with all specifications found in the installation specifications section. Do not overheat shut off valves on the condenser unit or evaporator unit. 2. Leak check field joints via the evaporator unit service valves. 3. Evacuate line set via the evaporator unit service valves. 4. Determine required charge size based on the model and line length. R404A Ice Machine Charge Specifications Line Run Charge 1000R Charge 1400R Charge 1650R 0 - 50 ft (0 - 15,2m) 8 lbs (4,9kg) 11 lbs (4,9kg) 11 lbs (4,9kg) 50 - 75 ft (15,2 - 22,9m) 9 lbs (5,4kg) 12 lbs (5,4kg) 12 lbs (5,4kg) 75 - 100 ft (22,9 - 30,5m) 10 lbs (5,9kg) 13 lbs (5,9kg) 13 lbs (5,9kg) 100 ft + (30,5m+) not recommended – consult factory 5. Open the liquid line service valve and suction line service valve on the evaporator unit and condenser unit. 6. Open the liquid line valve on the receiver, then the suction line valve on the compressor unit. 7. Liquid charge unit through liquid line shut off valve on the evaporator unit or receiver valve on the condensing unit. 8. Isolate the refrigerant tank from high pressure side on the system. 9. Turn on power to condensing unit and evaporator unit. 10. Complete system charge through low pressure side. 11. Insulate entire suction line including shut off valves to prevent condensation. 6 REMOTE CONDENSING UNIT Pressure adjustment 5.1 5 Check pressure adjustment 1. The pressure control is located in the electrical box near the refrigeration line set connection point. 2. Verify the control is set for system operation of 10 psi cut out and 30 psi cut in 3. If adjustment is needed always adjust the cut in first. Start up and test 6 NOTICE Ice machine MUST be cleaned and sanitized prior to operation! Consult Operation and Service Manual provided with ice machine for cleaning and sanitizing instructions. 6.1 Verify operation • Turn dispenser power ON if applicable • Check current draw of compressor to verify correct electrical operation • Put a piece of ice on bin thermostat or hold a cup under the shuttle actuator on the bin/ dispenser to verify that the evaporator unit shuts OFF; condensing unit pumps down and shuts off. • After shut off, restart the ice machine REMOTE CONDENSING UNIT Horizon Condenser Unit Compressor Amperage Single-Phase Model Number Compressor Running amps (+/- 10%) 1000R 00168054 AJA7490ZXD 7.4 1400R 00178640 AWA9517ZXN 14.7 1650R 00973925 AVA9522ZXN 22.6 Model Number Compressor Running amps (+/- 10%) 1000R 00990200 AWA9490ZXTHN 4.7 1400R 00990218 AWA9517ZXTHN 7.3 1650R 00990226 AVA9522ZXTHN 10.3 3-Phase 7 Harmony, Horizon, Ice Manager, RIDE, and Vision are trademarks of Follett Corporation. Chewblet and Follett are registered trademarks of Follett Corporation, registered in US. 801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com 00160002R09 4/12