 User  manual  1/10           User manualUser manualUser manualUser manual                      Ver 1.3
  User  manual  2/10  CCCChange historyhange historyhange historyhange history     revision  Updated date summary 1.0  Aug 1 2012  First edition 1.1  Aug 6 2012 Modification Page 6(DSSS/CCK->DSSS/BPSK),7(modification of consumption), 8(addition of following sentence) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including       interference that may cause undesired operation. 1.2  August 15 2012 -Fixing of 3.1(delete comments of remarks) - addition of 5.6 Indicating compliance with ICES-003 1.3  August 28 2012 - Fixing of 4.3
  User  manual  3/10 Table of contentsTable of contentsTable of contentsTable of contents    1. Apprication ..................................................................................................................................... 4 2. System Configuration ..................................................................................................................... 4 3. Description of Meter (Host) ............................................................................................................ 5 3.1 Overview .................................................................................................................................... 5 3.2 Operating Range ........................................................................................................................ 5 4. Description of Module ( Module) .................................................................................................... 6 4.1 Overview .................................................................................................................................... 6 4.2 Operating Range ........................................................................................................................ 6 4.3 Major element ............................................................................................................................ 6 4.4 Basic specification  【module】 .................................................................................................... 7 5. Required FCC and IC statement ( Host ) ....................................................................................... 8 5.1 FCC §15.21 ................................................................................................................................ 8 5.2 FCC §15.105 .............................................................................................................................. 8 5.3 RSS-Gen §7.1.2. ........................................................................................................................ 8 5.4 RSS-Gen §7.1.3. ........................................................................................................................ 8 5.5 Indicating safe separation distance warning .............................................................................. 9 6. Required FCC and IC statement (Module)...................................................................................10 6.1 FCC §15.21 ..............................................................................................................................10 6.2 FCC §15.105 ............................................................................................................................10 6.3 RSS-Gen §7.1.2. ......................................................................................................................10 6.4 RSS-Gen §7.1.3. ......................................................................................................................10
  User  manual  4/10  1. Apprication This document shows the description of wattmeter(hereinafter called meter)and mounted   communication board(hereinafter called module).  -  target meters : GE I210+ Meter    FM1S / FM2S / FM12S / FM25S -  Module           : Fujitsu YAA75-0402  2. System Configuration Fig2-1 is general system configuration of using meter. Installed meters in each house is communicated to Center via Repeaters and Gateways and control   the meter-reading value etc.automatically.  Red line of Fig.2-1 is the applicable scope of this document.     Fig2-1 System configuration     Substation Poles Houses…..CenterServer -DHCP ServerRouterRouter Fiber-optnetwork SwitchMeters RepeatersGateway
  User  manual  5/10 3. Description of Meter (Host) 3.1  Overview Form and overview of meter are as follows.  Category Meter form Remark FM1S FM2S FM12S FM25S Input voltage 120VAC  240VAC  120VAC or 240VAC 120VAC or 240VAC  enclosure Same form   Meter panel board  Same board Meter socket type  Different type Mouted module Same module meter panel interface  Same interface   AC power cable  Same cable     3.2  Operating Range • Voltage                              :   + - 20% (or ±20%) • Temperature                   :   -40°C through +85°C • Typical Starting Watts   :   <=5.0 Watts (Form 2S 240V CL200) • Typical Watts Loss          :   0.7 Watts • Typical Accuracy          :   Within +/- 0.2%
  User  manual  6/10 4. Description of Module ( Module) 4.1  Overview The module mounted to each meter in paragraph 3 collects the meter-reading values etc.   with controlling Center.  4.2  Operating Range Same as chapter 3.2.  4.3  Major element   Major elements of module are as follows.  No. component  summary  remark 1 Radio element  IEEE802. 11b Transmission power:100mW Modulation:DSSS / BPSK Data rate  :1Mbps   2222 Antenna  This antenna made by printed-circuit in the module.   3 Meter panel interface element Communication between Meter panel. Signals:refer to chapter 3.2   4 Power element  *AC cable(with ferrite bead) is connected to   this element. *This  element  steps  down  AC  input(120V/240V)  to +3.3VDC.  5 Dispray element  extinction power off or normal operation  LED(green) blinking  No operation ( start-up firmware) lighting  No operation(reset / no service) extinction normal  LED(red) blinking  fault lighting  reset                    AC cable with ferrite bead 120/ 240VAC Meter   *Display  *Meter   information   collection   Meter panel module Power element Radio element antenna element Meter Socket From electric pole 120VAC / 240VAC 120VAC   / 240VAC +3.3VDC UART/ Control signal Meter panel Interface element
  User  manual  7/10 4.4  Basic specification     【【【【module】】】】 No Item  specification 1 External interface Wireless  IEEE802. 11b  Meter Panel  Connector(10pin)  Power  Input : AC85~264V 2 Debug interface RESET  FRES1/2 Short-circuit MB86C90  JTAG:×1 AR2315  JTAG:×1  3 Display  LED  Status      :GREEN Alarm      :AMBER 4 Security  Tamper  Program Deletion 5 Power  Input  AC-DC Conversion  (120V/240V⇒3.3V) Frequency  50/60Hz consumption  Input    : Less than 8.49W(AC:120V/240V) Output : Less than 5.94W(DC:+3.3V)  6 Condition  Operating temperature -20℃~40℃   7 Cooling method  Air cooling without blower 8 Thunder surge Protection fuse varistor fuse
  User  manual  8/10   5. Required FCC and IC statement ( Host ) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  5.1  FCC §15.21 Changes or modifications not expressly approved by the party responsible for compliance could void   the user’s authority to operate the equipment.  5.2  FCC §15.105 For class B equipment: NOTE:   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful   interference in a residential installation. This equipment generates, uses and can radiate radio frequency   energy and, if not installed and used in accordance with the instructions, may cause harmful interference   to radio communications. However, there is no guarantee that interference will not occur in a particular   installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.  5.3  RSS-Gen §7.1.2. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio   interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada.   Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.  5.4  RSS-Gen §7.1.3. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation   of the device.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est   susceptible d'en compromettre le fonctionnement.
  User  manual  9/10 5.5  Indicating safe separation distance warning This equipment complies with radio frequency exposure limits set forth by the FCC and Industry Canada for an uncontrolled environment. This equipment should be installed and operated with a Minimum distance of 20cm between the device and the user or bystanders. This device must Not be co-located or operating in conjunction with any other antenna or transmitter.  Cet  équipement  est  conforme  aux  limites  d'exposition  aux  radiofréquences  définies  par  la  FCC  et Industrie Canada pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre le dispositif et l'utilisateur ou des tiers. Ce dispositif ne doit pas être utilisé a proximité d’une autre antenne ou d’un autre émetteur.  5.6  Indicating compliance with ICES-003 This Class B digital apparatus complies with Canadian ICES-003.  Cet appareil numérique de la classe or B est conforme à la norme NMB-003 du Canada
  User  manual  10/10  6. Required FCC and IC statement (Module) 6.1  FCC §15.21 Changes or modifications not expressly approved by the party responsible for compliance could void   the user’s authority to operate the equipment.  6.2  FCC §15.105 For class B equipment: NOTE:   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful   interference in a residential installation. This equipment generates, uses and can radiate radio frequency   energy and, if not installed and used in accordance with the instructions, may cause harmful interference   to radio communications. However, there is no guarantee that interference will not occur in a particular   installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.  6.3  RSS-Gen §7.1.2. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio   interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada.   Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.  6.4  RSS-Gen §7.1.3. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation   of the device.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est   susceptible d'en compromettre le fonctionnement.