GE MDS DS-SERIES4 MDS Four.9 Series Digital Radio System User Manual Manual Rev 1
GE MDS LLC MDS Four.9 Series Digital Radio System Manual Rev 1
GE MDS >
user manual
Microwave Data Systems MDS FOUR.9 Series Digital Radio System User Reference and Installation Guide PRELIMINARY Part No. 05-4561A01, Rev. A Date: 9 JUNE 2006 © 2006 Microwave Data Systems Inc. All Rights Reserved. This book and the information contained herein is the proprietary and confidential information of Microwave Data Systems Inc. that is provided by Microwave Data SystemsTM exclusively for evaluating the purchase of Microwave Data Systems Inc. technology and is protected by copyright and trade secret laws. No part of this document may be disclosed, reproduced, or transmitted in any form or by any means, electronic or mechanical, for any purpose without the express written permission of Microwave Data Systems Inc. For permissions, contact Microwave Data Systems Inc. Marketing Group at 1-585-241-5510 or 1-585242-8369 (FAX). Notice of Disclaimer The information and specifications provided in this document are subject to change without notice. Microwave Data Systems Inc. reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant. The Warranty(s) that accompany Microwave Data Systems Inc., products are set forth in the sales agreement/contract between Microwave Data Systems Inc. and its customer. Please consult the sales agreement for the terms and conditions of the Warranty(s) proved by Microwave Data Systems Inc. To obtain a copy of the Warranty(s), contact your Microwave Data Systems Inc. Sales Representative at 1-585-241-5510 or 1-585-242-8369 (FAX). The information provided in this Microwave Data Systems Inc., document is provided “as is” without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Some jurisdictions do not allow the exclusion of implied warranties, so the above exclusion may not apply to you. In no event shall Microwave Data Systems Inc. be liable for any damages whatsoever – including special, indirect, consequential or incidental damages or damages for loss of profits, revenue, use, or data whether brought in contract or tort, arising out of or connected with any Microwave Data Systems Inc., document or the use, reliance upon or performance of any material contained in or accessed from this Microwave Data Systems Inc. document. Microwave Data Systems’s license agreement may be provided upon request. Additional Terms and Conditions will be finalized upon negotiation or a purchase. The above information shall not be constructed to imply any additional warranties for Microwave Data Systems Inc. equipment including, but not limited to, warranties of merchantability or fitness for an intended use. Trademark Information Software Defined Indoor UnitTM (SDIDUTM) is a product and trademark of CarrierComm Inc. JavaTM is a trademark of Sun Microsystems Inc. Windows® is a registered trademark of Microsoft Corporation All other brand or product names are trademarks or registered trademarks of their respective companies or organizations. Table of Contents SAFETY PRECAUTIONS ......................................................................................................................1-1 SYSTEM DESCRIPTION .......................................................................................................................2-1 2.1 About This Manual............................................................................................................................2-1 2.2 Introduction .......................................................................................................................................2-1 2.3 System Features ...............................................................................................................................2-4 2.4 Physical Description ........................................................................................................................2-5 2.4.1 Model Types ................................................................................................................................2-6 2.4.2 Options ........................................................................................................................................2-7 2.4.3 Front Panel Indicators .................................................................................................................2-7 2.4.4 Front Panel Connections .............................................................................................................2-8 2.5 System Description ........................................................................................................................2-12 2.6 Consecutive Point Architecture ....................................................................................................2-15 2.7 2 + 0 (East-West) Configuration ....................................................................................................2-17 2.8 1+1 Protection .................................................................................................................................2-18 2.9 1 + 1 Multi-hop Repeater Configuration .......................................................................................2-19 2.10 Data Interfaces ................................................................................................................................2-21 2.11 Power Management ........................................................................................................................2-21 2.12 MDS FOUR.9 Series Software and Network Management..........................................................2-22 INSTALLATION .....................................................................................................................................3-1 3.1 Unpacking..........................................................................................................................................3-1 3.2 Notices ...............................................................................................................................................3-2 3.3 Required Tools..................................................................................................................................3-2 3.3.1 SDIDUTM Tools ............................................................................................................................3-2 3.3.2 ODU Tools...................................................................................................................................3-2 3.4 PRE-INSTALLATION NOTES ...........................................................................................................3-3 3.5 Overview of Installation and Testing Process ...............................................................................3-3 3.6 Site Evaluation ..................................................................................................................................3-5 3.6.1 Preparing for a Site Evaluation....................................................................................................3-6 3.6.2 Site Evaluation Process...............................................................................................................3-7 3.6.3 Critical System Calculations ......................................................................................................3-12 3.6.4 Frequency Plan Determination..................................................................................................3-13 3.6.5 Antenna Planning ......................................................................................................................3-14 3.6.6 ODU Transmit Power Setup ......................................................................................................3-15 3.6.7 Documenting a Site Evaluation .................................................................................................3-16 3.7 Installation of the MDS FOUR.9 Series.........................................................................................3-19 3.7.1 Installing the MDS FOUR.9 Series Software Defined IDUTM ....................................................3-19 3.7.2 Installing the MDS FOUR.9 Series ODU...................................................................................3-20 3.7.3 Routing the ODU/ SDIDUTM Interconnect Cable .......................................................................3-22 3.8 Quick Start Guide ...........................................................................................................................3-24 3.8.1 Materials Required ....................................................................................................................3-24 3.8.2 Grounding the ODU...................................................................................................................3-24 3.8.3 3.8.4 3.8.5 3.8.6 3.8.7 3.9 Grounding the SDIDUTM ............................................................................................................3-26 Connecting the SDIDUTM to the PC and Power Source............................................................3-26 SDIDUTM Configuration..............................................................................................................3-27 ODU Antenna Alignment ...........................................................................................................3-29 Quick Start Settings...................................................................................................................3-30 Documenting MDS FOUR.9 Series Configuration.......................................................................3-31 SUMMARY SPECIFICATION ................................................................................................................4-1 FRONT PANEL CONNECTORS ...........................................................................................................5-1 5.1 DC Input (Power) Connector............................................................................................................5-1 5.2 Ethernet 100BaseTX Payload Connector 1-2.................................................................................5-1 4.9 SONET Payload Connector..............................................................................................................5-2 5.4 STM-1 Payload Connector ...............................................................................................................5-2 5.5 DS-3/E-3/STS-1 Payload Connector................................................................................................5-2 5.6 NMS 10/100BaseTX Connector 1-2 .................................................................................................5-3 5.7 Alarm/Serial Port Connector............................................................................................................5-3 5.8 ODU Connector.................................................................................................................................5-4 5.9 T1- Channels 1-2 Connector ............................................................................................................5-4 5.10 T1- Channels 3-16 Connector ..........................................................................................................5-5 5.11 USB ....................................................................................................................................................5-7 5.12 Voice Order Wire...............................................................................................................................5-8 5.13 Data Order Wire ................................................................................................................................5-8 APPENDIX .............................................................................................................................................6-1 6.1 Alarm Descriptions...........................................................................................................................6-1 6.2 Abbreviations & Acronyms............................................................................................................6-14 1 Safety Precautions PLEASE READ THESE SAFETY PRECAUTIONS! RF Energy Health Hazard The radio equipment described in this guide uses radio frequency transmitters. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than 119 cm (47.2) to the front of the antenna while the transmitter is operating. The antenna must be professionally installed on a fixed-mounted outdoor permanent structure to provide separation from any other antenna and all persons as detailed in this manual. Protection from Lightning Article 810 of the US National Electric Department of Energy Handbook 1996 specifies that radio and television lead-in cables must have adequate surge protection at or near the point of entry to the building. The code specifies that any shielded cable from an external antenna must have the shield directly connected to a 10 AWG wire that connects to the building ground electrode. Warning – This is a Class A product Warning – This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Warning – Turn off all power before servicing Warning – Turn off all power before servicing this equipment. Safety Requirements Safety requirements require a switch be employed between the SDIDU™ external power supply and the SDIDU™ power supplies. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 1-2 Proper Disposal The manufacture of the equipment described herein has required the extraction and use of natural resources. Improper disposal may contaminate the environment and present a health risk due to the release of hazardous substances contained within. To avoid dissemination of these substances into our environment, and to lessen the demand on natural resources, we encourage you to use the appropriate recycling systems for disposal. These systems will reuse or recycle most of the materials found in this equipment in a sound way. Please contact Microwave Data Systems or your supplier for more information on the proper disposal of this equipment. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A 2 System Description 2.1 About This Manual This manual is written for those who are involved in the “hands-on” installation of the MDS FOUR.9 Series Digital Transceiver, such as installation technicians, site evaluators, project managers, and network engineers. It assumes the reader has a basic understanding of how to install hardware, use Windows based software, and operate test equipment. The MDS FOUR.9 Series includes a Software Defined Indoor UnitTM (SDIDUTM) and outdoor unit (ODU). The SDIDUTM is a product and trademark of CarrierComm. 2.2 Introduction The Microwave Data Systems family of digital radios provides high capacity transmission, flexibility, features, and convenience for wireless digital communications networks. The Microwave Data Systems digital point-to-point radios represent a new microwave architecture that is designed to address universal applications for both PDH and SDH platforms. This advanced technology platform is designed to provide the flexibility to customers for their current and future network needs. The Microwave Data Systems radio family is based upon a common platform to support a wide range of network interfaces and configurations. It supports links for 16 x E1/T1, 100BaseTX Ethernet, and DS-3/E-3/STS-1 (optional, consult factory for availability). The radio family is spectrum and data rate scalable, enabling service providers or organizations to trade-off system gain with spectral efficiency and channel availability for optimal network connectivity. The Microwave Data Systems digital radio family enables network operators (mobile and private), government and access service provides to offer a portfolio of secure, scalable wireless applications for data, video, and Voice over IP (VoIP). The MDS FOUR.9 Series digital radio family operates in the FCC Public Safety Band of 4.940 to 4.990 GHz, which is generically referred to as the “4.9 GHz band.” The MDS FOUR.9 Series supports three types of user data payload connectivity as follows: • 100Base-TX intelligent bridging between two locations without the delay and expense of installing cable or traditional microwave. • Scalable Ethernet capability of 25 and 50 Mbps is included. These scalable radios provide LAN connectivity and offer performance trade-offs between operational bandwidths, data rates, and distance. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide • 2-2 16E1 or T1 for cellular backhaul, enterprise voice applications and voice network redundancy For customers such as cellular carriers requiring backhaul and backbone extension as well as service providers requiring network redundancy, new Points of Presence (POPs), and last mile access, the MDS FOUR.9 Series radio is a cost effective alternative to leased lines with carrierclass quality of performance. The MDS FOUR.9 Series is a cost effective solution to meet the growing demand for enterprise Local Area Network (LAN) connectivity between buildings and campuses as well as service providers requiring reliable products for infrastructure expansion, extending Metropolitan Area Network (MAN) fiber access, and network redundancy. The MDS FOUR.9 Series includes integrated Network Management functionality and design features enabling simple commissioning when the radio network is initially set up in the field at the customer’s premises. Furthermore, a highlight of MDS radio products is scalability and the capability to support a ring-type architecture. This ring or consecutive point radio architecture is self-healing in the event of an outage in the link and automatically re-routes data traffic, thereby ensuring that service to the end user is not interrupted. The MDS FOUR.9 Series is composed of a Software Defined Indoor UnitTM (SDIDUTM) and Outdoor Unit (ODU). It supports 1+0 and 1+1 protection and ring architectures in a single 1 RU chassis. The modem and power supply functions are supported using easily replaceable plug-in modules. An additional feature of the SDIDUTM is provision for a second plug-in modem/IF module to provide repeater or east/west network configurations. The overall architecture consists of a single 1RU rack mount Software Defined Indoor Unit (SDIDUTM) with a cable connecting to an Outdoor Unit (ODU) with an external antenna. Core Access Network Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Indoor Unit Figure 2-1. MDS FOUR.9 Series SDIDUTM and ODU Architecture Table 2-1 lists key features that MDS FOUR.9 Series technology offers to those involved in the design, deployment and support of broadband fixed wireless networks. 145H142H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-3 Table 2-1 Key Benefits and Advantages of MDS FOUR.9 Series Radios Benefits Advantages to Providers/Customers Reference Wireless license-exempt system ISM bands do not require expensive license band fees or incur licensing delays. Fast return on investment. 2.2 – 2.4 146H143H 147H144H Lower total cost of total ownership. Wireless connectivity supplements existing cable (Ethernet). Media diversity avoids single points of failure. Easy to install units Straightforward modular system enables fast deployment and activation. Fast return on investment. 3.5 148H145H No monthly leased line fees. Carrier-class reliability. Complete support of payload capacity with additional wayside channels Aggregate capacity beyond basic payload (34 Mbps or 50 Mbps or 100 Mbps). Scalable and spectrally efficient system. Separate networks for radio overhead/management and user payload. Increases available bandwidth of network. 2.2– 2.5 149H146H 150H147H Allows customer full use of revenuegenerating payload channel. Up to 16 T1/E1 wayside channels supports extension of PBX connectivity between buildings without additional leased-line costs. Lowers total cost of ownership. Ring Architecture Supports a ring (consecutive point) configuration, thus creating a self-healing redundancy that is more reliable than traditional point-to-point networks. In the event of an outage, traffic is automatically rerouted via another part of the ring without service interruption. Ring/consecutive point networks can overcome line-of-sight issues and reach more buildings than other traditional wireless networks. 2.6,2.7,2.9 Enables network scalability. Increases deployment scenarios for initial deployment as well as network expansion with reduced line-of-sight issues. Increases network reliability due to selfhealing redundancy of the network. Minimizes total cost of ownership and maintenance of the network. Allows for mass deployment. Networks can be expanded by adding more MDS FOUR.9 Series units or more rings without interruption of service. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-4 Benefits Advantages to Providers/Customers Reference A separate management channel allows for a dedicated maintenance ring with connections to each radio on the ring. Adaptive Power Control Automatically adjusts transmit power in discrete increments in response to RF interference. For EIRP compliance, the power output is limited to the maximum established at the time of installation, per FCC Part 90 rules. Enables dense deployment. Simplifies deployment management. 2.11 and network Comprehensive Link/Network Management Software A graphical user interface offers security, configuration, fault, and performance management via standard craft interfaces. Suite of SNMP-compatible network management tools that provide robust local and remote management capabilities. Simplifies management of radio network and minimizes resources as entire network can be centrally managed from any location. 2.12 Simplifies troubleshooting of single radios, links, or entire networks. Simplifies network upgrades with remote software upgrades. Allows for mass deployment. 2.3 System Features Selectable Rates and Interfaces Up to 16 x E1/T1 (wayside channels) 100BaseTX/Ethernet: Scalable 25-100 Mbps DS-3/E-3/STS-1 (option; consult factory for availability) Support for multiple configurations 1+0, 1+1 protection/diversity Hot Standby East/West Repeater (2 + 0) © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-5 Selectable Spectral Efficiency of 0.8 to 6.25 bits/Hz (including FEC and spectral shaping effects) QPSK, 16 – 64 QAM Modulation Powerful Trellis Coded Modulation concatenated with Reed-Solomon Error Correction Built-in Adaptive Equalizer Support of Voice Orderwire Channels Peak output power at antenna port 24.4 dBm at 4.9 GHz (High Power) 17.1 dBm at 4.9 GHz (Low Power) Receive Sensitivity: -84 dBm to -72 dBm (depending on data rate/modulation/FEC/ODU) Adaptive Power Control—Adjusts power output to account for changing path conditions. Power is limited to the maximum established at the time of installation, per FCC Part 90. Built-in Network Management System (NMS) Consecutive Point ring architecture Built-in performance statistics Built-in Bit Error Rate (BER) performance monitoring Data encryption of all payload data and T1/E1 wayside channels for MDS FOUR.9 Series-100 and MDS FOUR.9 Series-50 Ethernet models (Consult factory for availability) 2.4 Physical Description The following section details the physical features of the MDS FOUR.9 Series digital radios • Model types • Front panel indicators • Front panel connections © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-6 2.4.1 Model Types Table 2-2 lists the MDS FOUR.9 Series digital radios according to model number and associated capabilities of throughput, data interface, and wayside channel. 158H155H 159H156H Table 2-3 lists the ODU model numbers. Table 2-2 MDS FOUR.9 Series SDIDUTM Model Types PRODUCT NAME MODEL NUMBER FULL DUPLEX THROUGHPUT DATA INTERFACE WAYSIDE 4.9 GHz: MDS FOUR.9 Series SDIDU49MNVN 100 Mbps Aggregate 100 BaseTX Two T1/E1s 100 BaseTX Two T1/E1s 100 BaseTX Two T1/E1s 100 BaseTX Two T1/E1s 1-16xE1/T1 Scalable Ethernet, 2 Mbps 1-16xE1/T1 Scalable Ethernet, 2 Mbps (50 Mbps full duplex) 4.9 GHz: MDS FOUR.9 Series SDIDU49MPVN 100 Mbps Aggregate (50 Mbps full duplex), 1+1 Protection or 2+0 4.9 GHz: MDS FOUR.9 Series SDIDU49MNCN 200 Mbps Aggregate (100 Mbps full duplex) 4.9 GHz: MDS FOUR.9 Series SDIDU49MPCN 200 Mbps Aggregate (100 Mbps full duplex), 1+1 Protection or 2+0 4.9 GHz: MDS FOUR.9 Series SDIDU49MNTN 68 Mbps Aggregate (34 Mbps full duplex) + scalable ethernet 4.9 GHz: MDS FOUR.9 Series SDIDU49MPTN 72 Mbps Aggregate (36 Mbps full duplex), 1+1 Protection or 2+0 © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-7 Table 2-3 MDS FOUR.9 Series ODU Model Types PRODUCT NAME MODEL NUMBER MDS FOUR.9-ODU53e ODU4900MEP ANTENNA External antenna required 2.4.2 Options The following items are also available: • AC/DC power supply • Data Encryption • Upgrade 50Mbps Ethernet systems to 100Mbps capability • OC-3/STM-1 Mini-IO Module Please consult the factory for more information. 2.4.3 Front Panel Indicators All models of the MDS FOUR.9 Series support a variety of front panel configurations that are dependent on the network interface and capacity configurations. Figure 2-2 provides an example of the MDS FOUR.9 Series 1+0 configuration and the associated LEDs displayed on the SDIDUTM front panel. The controller, standard I/O, and each modem card have a status LED. 160H157H Figure 2-2. MDS FOUR.9 Series LEDs: SDIDUTM Front Panel Configuration for 1+0 Configuration The modem status LED indicates the modem status as described in Table 2-4. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-8 Table 2-4. Modem status LED. LED STATUS Green Active Locked Link Orange Standby Locked Link (1+1 Non-Diversity Only) Flashing Green Low SNR Flashing Orange Unlocked The controller status LED is the primary front panel indicator of alarms. An alarm is generated when a specific condition is identified and is cleared when the specified condition is no longer detected. When an alarm is posted, 1. The controller status LED turns orange for 5 seconds 2. The controller status LED turns off for 5 seconds 3. The controller status LED flashes orange the number of times specified by the first digit of the alarm code 4. The controller status LED turns off for 3 seconds 5. The controller status LED flashes orange the number of times specified by the second digit of the alarm code Steps 2-5 are repeated for each alarm posted. The entire process is repeated as long as the alarms are still posted. The standard I/O and modem status LEDs are set to red when certain alarms are posted. A complete list of alarms is provided in Appendix 6.1. 161H158H The alarm description is also displayed in the Graphical User Interface (GUI) as described in the User Interface Reference Manual. 2.4.4 Front Panel Connections Please refer to the Figure 2-3 for an example of a MDS FOUR.9 Series SDIDUTM front panel followed by a descriptive text of the connections. 162H159H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-9 Figure 2-3. MDS FOUR.9 Series, 1+1 Protection: SDIDUTM Front Panel Connections © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-10 Power Supply Input DC Input -48 VDC -48v (Isolated Input); 2-pin captive power connector. The unit requires an input of -48 volts dc ±10% at the front panel DC Input connector. The total required power is dependent on the option cards and protection configuration (1+0, 1+1). The SDIDUTM front panel power connector pin numbering is 1 through 2, from left to right, when facing the unit front panel. Pin 1 is the power supply return and is connected to unit chassis ground internally. Pin 2 should be supplied with a nominal -48 V dc, with respect to the unit chassis (ground). A ground-isolated supply may be used, provided it will tolerate grounding of its most positive output. The recommended power input is -44 to -52 V dc at 2 Amps minimum. It is recommended that any power supply used be able to supply a minimum of 100 Watts to the SDIDUTM. A mating power cable connector is supplied with the SDIDUTM. It is a 2-pin plug, 5 mm pitch, manufactured by Phoenix Contact, P/N 17 86 83 1 (connector type MSTB 2,5/2-STF). This connector has screw clamp terminals that accommodate 24 AWG to 12 AWG wire. The power cable wire should be selected to provide the appropriate current with minimal voltage drop, based on the power supply voltage and length of cable required. The recommended wire size for power cables under 10 feet in length supplying -48 Vdc is 18 AWG. The SDIDUTM supplies the ODU with all required power via the ODU/SDIDUTM Interconnect cable. The SDIDUTM does not have a power on/off switch. When DC power is connected to the SDIDUTM, the digital radio powers up and is operational. There can be up to 204 mW of RF power present at the antenna port (external antenna version). The antenna should be directed safely when power is applied. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-11 Alarm/Serial Interface Alarms/Serial DB-15HD female connector for two Form-C relay alarm outputs (rated load: 1A @ 24 VDC), two TTL alarm outputs, four TTL alarm inputs, and Serial Console. The two Form-C relay alarm outputs can be configured to emulate TTL alarm outputs. USB Interface USB USB connector, optional. Voice Orderwire Connector Voice Orderwire Call Call button to alert operator at link-partner SDIDUTM of incoming Voice-Orderwire call. Voice Orderwire RJ-11 modular port connector for voice orderwire interface. NMS 10/100 Network Management System Connections NMS 10/100 1 10/100Base-TX RJ-45 modular local port connector for access to the Network Management System (SNMP) and GUI. NMS 10/100 2 10/100BaseTX RJ-45 modular remote port connector for access to the Network Management System (SNMP). This port to be used for consecutive point networks. 100/Ethernet Models: Ethernet 100BaseT Connections USER 10/100 1 100Base-TX RJ-45 modular port connector for the local Fast Ethernet interface. USER 10/100 1 100Base-TX RJ-45 modular port connector. This port to be used for consecutive point networks. T1 Channels T1 1-2 Two T1/E1 (RJ-48C) interface connections. T1 3-16 Fourteen T1/E1 high density interface connector © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-12 2.5 System Description The overall digital radio architecture consists of a single 1RU rack mount Software Defined Indoor UnitTM (SDIDUTM) with a cable connecting to an Outdoor Unit (ODU). The 4.9 GHz ODU is designed for use with an external antenna only. This SDIDUTM /ODU architecture is advantageous when compared to a single IDU with external mount antenna, since supporting a signal of 4.9 GHz from the IDU rack to the antenna will result in significant signal degradation, which would require expensive coaxial cable or waveguide. Figure 2-4 shows the SDIDUTM and interfaces from a functional point of view. The functional partitions for the I/O, Modem/IF, and power supply modules are shown. The SDIDUTM comes with the standard I/O capability that can be upgraded. In addition, the Modem/IF function is modular. This allows the addition of a second Modem to support protection or ring architectures. The power supply is similarly modular. 163H160H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-13 IDU IDU CONTROLLER CPU RCH Serial SNMP 2x 100Base-Tx Switch 2x 100 Mbps User 2x 100Base-Tx Switch 16x 1.544/2.048 Mbps 16 T1/E1 2x 100 Mbps Modem Control Telemetry Serial East/Primary Modem MODEM/ FEC ASIC Digital IF Multiplexed IF Quad Mux -48Vdc 64 kbps Voice West/Secondary Modem Standard I/O Cards Optional I/O Cards (Small Slot) 155.52 Mbps 4x44.736/34.368/ 51.84 Mbps MODEM/ FEC ASIC FRAMER STM-1/OC3 Digital IF DS-3/ES/ STS-1 2xSTM-1/ OC3 4x44.736/34.368/ 51.84 Mbps 4xDS3/ES/ STS1 Multiplexed IF -48Vdc Optional I/O Cards (Large Slot) 2x 155.52 Mbps Quad Mux Primary Power Supply -48Vdc Secondary Power Supply -48Vdc Future ODU Vertical Antenna 350 MHz Transfer Switch Duplexer Transmitter Up-Converter TNC N-type 5.3/ 5.8 GHz Quad Mux Receiver 140 MHz -48Vdc 5/10 MHz Diversity Switch Down-Converter DC/DC Converters External Antenna +10Vdc +5Vdc +3Vdc -5Vdc Commlink & Processor Internal/ Horizontal Antenna BNC RSL (Received Signal Level) Voltage Figure 2-4. MDS FOUR.9 Series System Block Diagram The SDIDUTM interfaces with the ODU to receive and provide modulated transmit and receive waveforms. The SDIDUTM interfaces provide Fast Ethernet 100Base-T (MDS FOUR.9 Series100) connections to the network. Contact factory for availability of SONET OC-3 (MDS FOUR.9 Series-155) connections. In addition, two E1/T1 channels are provided for PBX extension. SNMP is provided on 10/100BaseT ports. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-14 The ODU RF Up/Down Converter card provides the interface to the antenna. The transmit section up-converts and amplifies the modulated Intermediate Frequency (IF) of 350 MHz from the IF Processor and provides additional filtering. The receive section down converts the received signal, provides additional filtering, and outputs an IF of 140 MHz to the IF Processor. The 64-QAM Modem performs the modulation and demodulation of the payload and forward error correction using advanced modulation and coding techniques. Using all-digital processing, the 64-QAM Modem uses robust modulation and forward error correction coding to minimize the number of bit errors and optimize the radio and network performance. The 64-QAM Modem also scrambles, descrambles and interleaves/deinterleaves the data stream in accordance with Intelsat standards to ensure modulation efficiency and resilience to sustained burst errors. The modulation will vary by application, data rate, and frequency spectrum. The highest order modulation mode supported is 64 Quadrature Amplitude Modulation (QAM). Table 2-5 summarizes the TCM/convolutional code rates for each modulation type supported by the MDS FOUR.9 Series. 164H161H Table 2-5. MDS FOUR.9 Series TCM/Convolutional Code Rates Modulation Type Available Code Rates QPSK 1/2, 3/4, 7/8 16-QAM 3/4, 7/8, 11/12 32-QAM 4/5, 9/10 64-QAM 5/6, 11/12 The major functions of the SDIDUTM can be summarized as follows: • I/O Processing – The SDIDUTM comes with a standard I/O capability that includes support for up to 16xT1/E1 and 2x100Base-TX user payloads, 2x100Base-TX for SNMP, and voice orderwire. In addition, option cards for DS-3/E3/STS-1, 1-2 x STM-1/OC-3, and 4xDS-3/E3/STS-1 may be added. The SDIDUTM architecture is flexible and allows for the addition of other I/O types in the future. • Switch/Framing – The SDIDUTM includes an Ethernet Switch and a proprietary Framer that are designed to support 1+1 protection switching, ring architecture routing, and overall network control functions. • Network Processor – The SDIDUTM includes a Network Processor that performs SNMP and Network Management functions. • Modem/IF – The SDIDUTM Modem performs forward-error-correction (FEC) encoding, PSK/QAM modulation and demodulation, equalization, and FEC decoding functions. The IF chain provides a 350 MHz carrier, receives 140 a MHz carrier, processes OOK telemetry, and provides –48V power. Two modems can be used for 1+1 protection or ring architectures. • Power Supply – The SDIDUTM power supply accepts -48 Vdc and supplies the SDIDUTM and ODU with power. A second redundant power supply may be added as an optional module. The Modem Processor and its associated RAM, ROM, and peripherals control the digital and analog Modem operation. It also provides configuration and control for both the IF and I/O cards. The © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-15 SDIDUTM interfaces with the ODU to receive and provide modulated transmit and receive waveforms. The SDIDUTM also provides the physical interface for the user payload and network management. In transmit mode, the Framer merges user payload with radio overhead-encapsulated network management data. This combined data stream is transmitted without any loss of user bandwidth. In the receive mode, the Framer separates the combined data stream received from the 64-QAM Modem. The SDIDUTM supports Scalable Ethernet data rates, such as 25 or 50 Mbps via the 100BaseT data interface port. The SDIDUTM provides network management data on 10 Mbps ports accessible via the 10/100BaseTX port. The Central Processor Unit (CPU) provides the embedded control and network element functionality of the NMS. The CPU also communicates with other functions within the SDIDUTM for configuration, control, and status monitoring. In Ethernet models, the payload of each user Ethernet data packet and all T1 can be encrypted using an AES encryption algorithm. In addition, the encryption engine is re-seeded with a new, randomly generated key stream every 10 seconds, in order to provide enhanced security. The initial key is based off of a pass phrase entered into each MDS FOUR.9 Series unit by the network administrator. Consult factory for the availability of this encryption function. The power supply converts -48 Vdc to the DC voltage levels required by each component in the system. 2.6 Consecutive Point Architecture The consecutive point network architecture is based upon the proven SONET/SDH ring. Telecommunications service providers traditionally use the SONET/SDH ring architecture to implement their access networks. A typical SONET/SDH network consists of the service provider’s Point of Presence (POP) site and several customer sites with fiber optic cables connecting these sites in a ring configuration (see Figure 2-5). This architecture lets providers deliver high bandwidth with high availability to their customers. 165H162H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-16 Figure 2-5. Ring Configuration. SONET/SDH rings are inherently self-healing. Each ring has both an active path and a standby path. Network traffic normally uses the active path. Should one section of the ring fail, the network will switch to the standby path. Switchover occurs in seconds. There may be a brief delay in service, but no loss of payload, thus maintaining high levels of network availability. The consecutive point architecture implemented in the MDS FOUR.9 Series Digital Radio family is based on a point-to-point-to-point topology that mimics fiber rings, with broadband wireless links replacing in-ground fiber cable. A typical consecutive point network consists of a POP and several customer sites connected using MDS FOUR.9 Series units. These units are typically in a building in an east/west configuration. Using east/west configurations, each unit installed at a customer site is logically connected to two other units via an over-the-air radio frequency (RF) link to a unit at an adjacent site. Each consecutive point network typically starts and ends at a POP. A pattern of wireless links and in-building connections is repeated at each site until all buildings in the network are connected in a ring as shown in Figure 2-6. . For 2 x 1+0 and 2 x 1+1 nodes payload and NMS connections need to be jumpered between two SDIDUTMs. For 1 x 2+0 nodes, there is no need for jumpers as there is a single SDIDUTM. For SDH or SONET payloads, the configuration is similar but an external add/drop mux and a second SDH/SONET interface card are required. 166H163H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-17 Figure 2-6. Consecutive Point Network 2.7 2 + 0 (East-West) Configuration The SDIDUTM supports an east/west, or 2+0, configuration that allows a consecutive point architecture to be achieved with only a single 1 RU chassis at each location. In this configuration the SDIDUTM contains two modems supplies and may contain two power supplies. One modem is referred to as the west modem and the other as the east modem. The SDIDUTM is connected to two ODUs, one broadcasting/receiving in one direction of the ring architecture and the other broadcasting/receiving in the other as shown in Figure 2-7. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Connected to east modem 2-18 Connected to west modem Connected to west modem Connected to west modem Connected to east modem Connected to east modem Connected to east modem Connected to west modem Figure 2-7. 2+0 (East-West) configuration. 2.8 1+1 Protection The MDS FOUR.9 Series supports 1+1 protection as an option for a critical link. In this configuration, protection is provided in a single 1 RU chassis. The SDIDUTM contains two power supplies and two modems. The power supply, ODU, IF/telemetry and modem are protected. The digital framing and LIUs are not. One modem is referred to as the west modem and the other as the east modem. 1+1 protection can be run in two modes called diversity and non-diversity. In diversity mode, the link between each pair of modems is the same, as shown in Figure 2-8, providing complete redundancy. This arrangement requires bandwidth for both links and noninterference between the links, but it provides hitless receive and transmit switching. The SDIDUTM supports both frequency and spatial diversity. In frequency diversity, two frequencies are used. In spatial diversity, two non-interfering paths are used. In either case, the proprietary framer chooses the best, or error-free, data stream and forwards it to the Line Interface Units (LIUs). 168H165H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-19 Connected to west modem Connected to west modem Connected to east modem Connected to east modem Figure 2-8. 1+1 protection in diversity mode Figure 2-9 shows operation in non-diversity mode. In this mode, one ODU at each location transmits to both two ODUs at the other location. This mode does not require the extra bandwidth or interference protection of diversity mode. It provides hitless receive switching and hot standby. The SDIDUTM automatically switches transmit ODU upon appropriate ODU alarm or ODU interface error, minimizing transmit outage time. 169H166H Connected to west modem Connected to west modem Connected to east modem Connected to east modem Figure 2-9. 1+1 protection in non-diversity mode 2.9 1 + 1 Multi-hop Repeater Configuration The MDS FOUR.9 Series supports a 1 + 1 multi-hop repeater configuration with drop/insert capability as shown in Figure 2-10. This configuration provides individual 1 + 1 link protection as described in section 2.8, as well as the full-scale protection inherent in the consecutive point architecture as described in section 2.6. At each location within the network, data may be dropped or inserted. Front panel connections for drop/insert capability are shown in Figure 2-11. In this configuration each SDIDUTM contains two power supplies and two modems. 171H168H 172H169H 173H170H 174H171H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-20 Protected Link Protected Link Data drop/insert Data drop/insert Data drop/insert Protected Link Protected Link Data drop/insert Figure 2-10. 1 + 1 Multi-hop Repeater Configuration © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-21 Figure 2-11. Front Panel connections in 1 + 1 multi-hop repeater configuration 2.10 Data Interfaces The I/O card has 2x100BaseTX interfaces that can be configured as either primary payload, or secondary wayside channels. The Over-the-air channel has a data-bandwidth capacity that is set by the frequency-bandwidth, modulation, and coding. The data-bandwidth may be allocated to various I/O card interfaces, including 155.52 Mbps for STM-1, 2 Mbps per E1, up to 100 Mbps Ethernet, and up to 1 Mbps NMS. Only up to 100 Mbps of data-bandwidth may be allocated for either net data, and the two I/O card 100BaseTX interfaces will share that 100 Mbps databandwidth. There is also an option mini-I/O card, which provides STM-1 Optical/OC-3 or STM-1 Electrical interfaces. The optical interface is single mode at 1300 nm. Consult factory for availability of Mini-IO STM-1/OC-3 Module. 2.11 Power Management RF power management is a radio design feature that controls the power level (typically expressed in dBm) of the RF signal received from a transmitter by a receiver. The traditional goal of power management is to ensure that the RF signal at a receiver is strong enough to maintain the radio link under changing weather and link conditions. Traditional power management techniques such as Constant Transmit Power Control (CTPC) and Automatic Transmit Power Control (ATPC) transmit at a high power level to overcome the effects of fading and interference. However, these techniques continue to operate at a higher © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 2-22 power level than needed to maintain the link in clear weather. Because transmit power remains high when the weather clears, the level of system interference increases. Radios operating at high transmit power will interfere with other radios, even if the interfering source is miles away from the victim. High interference levels can degrade signal quality to the point that wireless radio links become unreliable and network availability suffers. The traditional solution to system interference is to increase the distance between radios. However, the resulting sparse deployment model is inappropriate for metropolitan areas. In response to the need for a high-density deployment model the MDS FOUR.9 Series use a unique power control technique called AdTPC. AdTPC enables MDS FOUR.9 Series units to transmit at the minimum power level necessary to maintain a link regardless of the prevailing weather and interference conditions. The MDS FOUR.9 Series is designed and manufactured to not exceed the +30 dBm maximum power allowed. The purpose of power management is to minimize transmit power level when lower power levels are sufficient. AdTPC also extends the concept of power management by controlling not only the power (dBm) of the RF signal, but its quality (signal-to-noise ratio) as well. In contrast to ATPC, the AdTPC technique dynamically adjusts the output power based on both the actual strength and quality of the signal. Networked MDS FOUR.9 Series units constantly monitor receive power and maintain 10-12 BER performance under varying interference and climate conditions. Each MDS FOUR.9 Series unit can detect when there is a degradation in the received signal level of quality and adjust the transmit power level of the far-end MDS FOUR.9 Series unit to correct for it. AdTPC provides maximum power in periods of heavy interference and fading and minimum power when conditions are clear. Minimal transmit power reduces potential for co-channel and adjacent channel interference with other RF devices in the service area, thereby ensuring maximum frequency re-use. The resulting benefit is that operators are able to deploy more MDS FOUR.9 Series units in a smaller area. 2.12 MDS FOUR.9 Series Software and Network Management All of the MDS FOUR.9 Series parameters are accessible in three ways: 1. Using a standard web-browser via HTTP to access the built in webserver. 2. Via SNMP using the fully featured MIB, allowing for automation of data collection and network management. 3. Via a command line client accessible from a terminal client connected to the serial port, or telnet over the NMS Ethernet. The GUI, SNMP, and CLI control are discussed in the MDS FOUR.9 Series User Interface Manual. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A 3 Installation 3.1 Unpacking The following is a list of possible included items. Description Quantity Digital Radio SDIDUTM (1RU chassis) ODU (with hardware) Manual and/or Quick Start Guide SDIDUTM ODU Figure 3-1. MDS FOUR.9 Series Components Be sure to retain the original boxes and packing material in case of return shipping. Inspect all items for damage and/or loose parts. Contact the shipping company immediately if anything appears damaged. If any of the listed parts are missing, call the distributor or the factory immediately to resolve the problem. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-2 3.2 Notices CAUTION DO NOT OPERATE EXTERNAL ANTENNA ODU UNITS WITHOUT AN ANTENNA, ATTENUATOR, OR LOAD CONNECTED TO THE ANTENNA PORT. DAMAGE MAY OCCUR TO THE TRANSMITTER DUE TO EXCESSIVE REFLECTED RF ENERGY. ALWAYS ATTENUATE THE SIGNAL INTO THE RECEIVER ANTENNA PORT TO LESS THAN –20 dBm. THIS WILL PREVENT OVERLOAD AND POSSIBLE DAMAGE TO THE RECEIVER MODULE. WARNING HIGH VOLTAGE IS PRESENT INSIDE THE ODU and SDIDUTM WHEN THE UNIT IS PLUGGED IN. TO PREVENT ELECTRICAL SHOCK, UNPLUG THE POWER CABLE BEFORE SERVICING. UNIT SHOULD BE SERVICED BY QUALIFIED PERSONNEL ONLY. 3.3 Required Tools The following tools are needed for installation. 3.3.1 SDIDUTM Tools • 1/8” Slotted screwdriver for securing power supply connector • Screwdriver for rack mount assembly. Size and types depends on rack mount screws (not included). 3.3.2 ODU Tools • 13 mm or adjustable wrench for ODU bracket mounting bolts • 17 mm or adjustable wrench for U-Bolt © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-3 3.4 PRE-INSTALLATION NOTES It may be useful to gain familiarity with the MDS FOUR.9 Series via back-to-back bench testing prior to final installation. We highly recommend installation of lightning protectors on the ODU/SDIDUTM Interconnect Cable to prevent line surges from damaging expensive components. Back-to-back bench testing prior to final installation is highly recommended in order to gain familiarity with the product. The following additional equipment is required for back-to-back testing: • Low-loss cables, N-male connectors on ODU interfaces. • Two inline RF attenuators, 30 dB each, rated for ODU frequency. The SDIDUTM and ODUs must be configured in an operational configuration and set-up as shown in Figure 3-2. When equipment is connected in operational configuration, no errors should be reported on the front panel. 175H172H Ant. Port ODU - 1 Ant. Port 30 dB 30 dB ODU - 2 To IDU SDIDUTM - 1 SDIDUTM - 2 Figure 3-2. MDS FOUR.9 Series Back-to-Back Testing Configuration 3.5 Overview of Installation and Testing Process The installation and testing process is accomplished by performing a series of separate, yet interrelated, procedures, each of which is required for the successful implementation of a production MDS FOUR.9 Series network. These procedures are as follows: • Site Evaluation: gathering specific information about potential MDS FOUR.9 Series installation sites. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-4 • Cable and Installation: Testing and installing MDS FOUR.9 Series ODU cables and optional interface devices at installation sites. • MDS FOUR.9 Series ODU Mounting and Alignment: Mounting ODUs to a pole or wall, performing link alignment and radio frequency (RF) verification. • MDS FOUR.9 Series Digital Radio Configuration: Using MDS FOUR.9 Series Link Manager software to install network- and site-specific parameters in the radios. • MDS FOUR.9 Series Digital Radio Testing: Performing cable continuity checks and RF tests for links, the payload/radio overhead channel, and the management channel. The following diagram shows where installation and commissioning resides within the MDS FOUR.9 Series network deployment life cycle and defines the sequence in which the processes that comprise installation and commissioning should be performed. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-5 Network Life Cycle Customer Requirements RF Planning & Network Design Site Selection & Acquisition Network Operation & Maintenance Installation & Commissioning Network Upgrade & Expansion Perform Site Evaluation Mount and Align ODUs Install Cables Configure Digital Software Defined IDUTM PDH Type of Network? SDH Perform SDH Network Test Perform Fast PDH Network Test Installation & Commissioning Complete 03-01-013b 3.6 Site Evaluation A site evaluation consists of a series of procedures for gathering specific information about potential MDS FOUR.9 Series locations. This information is critical to the successful design and deployment of a network. Site evaluations are required to confirm whether or not a building meets network design requirements. The main objectives are as follows: © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide • • 3-6 Confirm • Line of sight for each link • MDS FOUR.9 Series ODU mounting locations • Site equipment locations • Cable routes • Any other potential RF sources Prepare site drawings and record site information 3.6.1 Preparing for a Site Evaluation The following tools are required to perform a site evaluation: • RF and network design diagrams (as required) • Binoculars • Global positioning system (GPS) or range finder • Compass • Measuring tape and/or wheel • Digital camera • Area map • Aerial photograph (if available) • List of potential installation sites (“targeted buildings”) The following tasks must be completed prior to performing a site evaluation: • • Prepare the initial network design by performing the following: • Identify potential buildings by identifying targeted customers (applicable if you’re a service provider) • Identify potential links by selecting buildings based on the high probability of line of sight Arrange for access with the facility personnel into the buildings, equipment rooms, and architectural plans to become familiar with the location of all ducts, risers, etc. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-7 3.6.2 Site Evaluation Process The following steps must be completed to perform a successful site evaluation. Each step in the process is detailed in the following subparagraphs: • Ensure RF Safety compliance: Ensure that appropriate warning signs are properly placed and posted at the equipment site or access entry. For a complete list of warnings, refer the Safety Precautions listed at the beginning of this manual. • Ensure Compliance with Laws, Regulations, Codes, and Agreements: Ensure that any installation performed as a result of the site evaluation is in full compliance with applicable federal and local laws, regulations, electrical codes, building codes, and fire codes. • Establish Radio Line of Sight between MDS FOUR.9 Series Radios: The most critical step in conducting a site evaluation is confirming a clear visual and radio Line of Sight (LOS) between a near MDS FOUR.9 Series Radio and a far MDS FOUR.9 Series Radio. If LOS does not exist, another location must be used. MDS FOUR.9 Series Radios in a link must have a clear view of each other, or visual “line of sight”. Binoculars may be used evaluate the path from the desired location of the near MDS FOUR.9 Series Radio to the desired location of the far MDS FOUR.9 Series Radio. To confirm Line of Sight: Ensure that no obstructions are close to the transmitting/receiving path. Take into consideration trees, bridges, construction of new buildings, unexpected aerial traffic, window washing units, etc. Ensure that each MDS FOUR.9 Series can be mounted in the position required to correctly align the MDS FOUR.9 Series with its link partner. MDS FOUR.9 Series Radios must also have a clear radio line of sight. If a hard object, such as a mountain ridge or building, is too close to the signal path, it can damage the radio signal or reduce its strength. This happens even though the obstacle does not obscure the direct, visual line of sight. The Fresnel zone for a radio beam is an elliptical area immediately surrounding the visual path. It varies in thickness depending on the length of the signal path and the frequency of the signal. The necessary clearance for the Fresnel zone can be calculated, and it must be taken into account when designing a wireless links. As shown in the picture above, when a hard object protrudes into the signal path within the Fresnel zone, knife-edge diffraction can deflect part of the signal and cause it to reach the receiving antenna slightly later than the direct signal. Since these deflected signals are out of phase with the direct signal, they can reduce its power or cancel it out © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-8 altogether. If trees or other 'soft' objects protrude into the Fresnel zone, they can attenuate (reduced the strength of) a passing signal. In short, the fact that you can see a location does not mean that you can establish a quality radio link to that location. Microwave Data Systems provides a link planner spreadsheet that calculates the Fresnel ratio and helps determine link feasibility. Contact your technical support representative for a copy of the spreadsheet. Determine MDS FOUR.9 Series ODU Mounting Requirements: MDS FOUR.9 Series ODUs can be mounted on an antenna mast, brick, masonry or wall. Refer to detailed installation sections. • Determine MDS FOUR.9 Series SDIDUTM Installation Location: MDS FOUR.9 Series SDIDUsTM can be installed tabletop or cabinet, wall mount, or rack mount. The site must provide DC power or an optional AC/DC converter may be used. Refer to detailed installation sections. • Document Potential Sources of Co-location Interference: When MDS FOUR.9 Series ODUs are located on a roof or pole with other transmitters and receivers, an interference analysis may be required to determine and resolve potential interference issues. The interference analysis needs to be performed by an RF engineer. The specific information required for each transmitter and receiver includes the following: • Transmitting and/or receiving frequency Type of antenna Distance from MDS FOUR.9 Series ODU (horizontal and vertical) Polarity (horizontal or vertical) Transmit power level Antenna direction Measure the Link Distance: The two ways to measure link distance are as follows: GPS: record the latitude and longitude for the near and far MDS FOUR.9 Series ODU sites and calculate the link distance. Record the mapping datum used by the GPS unit and ensure the same mapping datum is used for all site evaluations in a given network. Range finder: measure the link distance (imperial or metric units may be used). Once the link distance has been measured, verify that the link distance meets the availability requirements of the link. Microwave Data Systems has created a spreadsheet tool that calculates the link availability based on the details of the link. The Microsoft Excel spreadsheet is available on internet, at http://www.microwavedata.com/, and is shown on the following page. The following parameters should be entered (items in yellow): • Operating Frequency: Enter 4900 • Transmit Antenna Gain: Enter the gain of the external antenna. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-9 • Transmit Output Power: Selectable between +5 to +23dB in 1 dB steps. • Receive Antenna Gain: Enter the gain of the external antenna if used. • Link Distance: Enter distance in miles or kilometers (must select the correct units: miles or kilometers) • Fresnel Clearance Ratio: This is a factor indicating the radio line of sight. A clear radio line of site has a fresnel clearance ratio of +0.60. As the curvature of the earth or other obstacles degrade the radio line of sight, the ratio can drop to –1. A separate spreadsheet is provided to calculate the appropriate ratio. In this spreadsheet the path length, tower heights and heights of any obstructions or ridges in the path of the link are entered. • Climate Factor: Enter 0.1 for dry, 0.25 for average and 0.5 for humid environments • Terrain Factor: Enter 0.25 for mountainous, 1 for average, and 4 for smooth (water) • Determine the Length of Interconnect Cable from ODU to SDIDUTM: The primary consideration for the outdoor interconnect cable from the ODU to SDIDUTM is the distance and route between the ODU and SDIDUTM. Maximum cable lengths are listed in Table 3-1. 176H173H Table 3-1. Maximum cable lengths Loss at (dB/100 m) Cable Type 140 MHz 350 MHz Maximum Length* LMR-200 12.6 20.1 100 m LMR-300 7.6 12.1 165 m LMR-400 4.9 7.8 256 m RG-214 13.1 153 m Belden 7808 8.6 14 143 m * Does not account for connector loss. The link availability, dispersive fade margin and expected signal strength readings are calculated based on the entered parameters. Maximum link distances based on the antenna and transmitter power settings are also displayed. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-10 MDS FIVE series Link Planner: 5.3GHz Availability Parameter Operating Frequency (MHz) Transmit Antenna Gain (dBi) Transmitter Output Power (dBm Receive Antenna Gain (dBi) Link Distance Fresnel Clearance Ratio1,2 Climate Factor Terrain Factor MDS FIVE series Mode 5.3GHz Band 5.3G-25FE1 5.3G-25FE2 5.3G-25FE3 5.3G-50FE1 5.3G-50FE2 5.3G-50FE3 5.3G-100FE1 5.3G-16E1-2 5.3G-16T1-2 5.3G-16E1-3 5.3G-16T1-3 Value 5300 23 23 3.93 miles 0.60 0.25 Channel Modem Data Bandwidth Rate (Mbps) (MHz) 31.112E+6 30.0 31.112E+6 20.0 31.112E+6 13.3 56.733E+6 30.0 56.733E+6 20.0 56.733E+6 13.3 107.797E+6 30.0 36.918E+6 20.0 28.655E+6 20.0 36.918E+6 13.3 28.655E+6 13.3 Receiver Sensitivity3 (dBm) -83 -82 -82 -80 -77 -72 -73 -82 -84 -82 -84 Link Fade Margin (dB) ODU RSSI (dBm) Availability (%) 12 11 11 11 13 11 13 -71 -71 -71 -71 -71 -71 -71 -71 -71 -71 -71 99.9987 99.9984 99.9984 99.9975 99.9950 99.9845 99.9876 99.9984 99.9990 99.9984 99.9990 Note1: FCC's definition; negative clearance indicates no optical LOS; range is [-1,…,0.6]; 0.6 is radio LOS condition. Note2: Accounting for single knife-edge diffraction loss only. Note3: BER<<1e-6. Note4: Listed data rates inlcudes 2 E1 Wayside channels, except for 16E1/T1 modes. MDS FIVE series Mode 5.3G-25FE1 5.3G-25FE2 5.3G-25FE3 5.3G-50FE1 5.3G-50FE2 5.3G-50FE3 5.3G-100FE1 5.3G-16E1-2 5.3G-16T1-2 5.3G-16E1-3 5.3G-16T1-3 Receiver Modulation and Code Sensitivity3 Rate (dBm) QPSK 3/4 -83 16QAM 3/4 -82 16QAM 3/4 -82 16QAM 3/4 -80 32QAM 4/5 -77 64QAM 11/12 -72 32QAM 9/10 -73 16QAM 3/4 -82 16QAM 3/4 -84 16QAM 7/8 -82 16QAM 7/8 -84 Max Distance (miles) for Various Availability 99.9% 99.99% 99.999% © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-11 Path Length (Km ) TX Tow er Height (m ) RX Tow er Height (m ) Frequency (MHz) Calculated Fresnel Clearance Ratio 10 30 30 5800 0.48 MDS FIVE series Link Planner: Fresnel Zone Clearance Distance from TX (Km ) Optical LOS Height (m) Radio LOS (60% 1st 1st Earth Total Earth Fresnel Fresnel Fresnel Fresnel Obstruction Curvature 1 Terrain Clearance Clearance) Zone Zone Height (m ) Zone (m ) Height (m) Ratio Height (m) Radius (m ) Height (m ) 0.0 30.0 0.0 30.0 30.0 0.0 0.0 0.0 0.3 30.0 3.5 26.5 27.9 0.1 0.0 0.1 0.5 30.0 5.0 25.0 27.0 0.3 0.0 0.3 0.8 30.0 6.0 24.0 26.4 0.4 0.0 0.4 1.0 30.0 6.8 23.2 25.9 0.5 0.0 0.5 1.3 30.0 7.5 22.5 25.5 0.6 0.0 0.6 1.5 30.0 8.1 21.9 25.1 0.8 0.0 0.8 1.8 30.0 8.6 21.4 24.8 0.8 20.8 20.0 2.0 30.0 9.1 20.9 24.5 0.9 10.9 10.0 2.3 30.0 9.5 20.5 24.3 1.0 11.0 10.0 2.5 30.0 9.8 20.2 24.1 1.1 24.1 23.0 2.8 30.0 10.1 19.9 23.9 1.2 25.2 24.0 3.0 30.0 10.4 19.6 23.8 1.2 0.0 1.2 3.3 30.0 10.6 19.4 23.6 1.3 0.0 1.3 3.5 30.0 10.8 19.2 23.5 1.3 0.0 1.3 3.8 30.0 11.0 19.0 23.4 1.4 0.0 1.4 4.0 30.0 11.1 18.9 23.3 1.4 11.4 10.0 4.3 30.0 11.2 18.8 23.3 1.4 0.0 1.4 4.5 30.0 11.3 18.7 23.2 1.5 0.0 1.5 4.8 30.0 11.3 18.7 23.2 1.5 0.0 1.5 5.0 30.0 11.4 18.6 23.2 1.5 0.0 1.5 5.3 30.0 11.3 18.7 23.2 1.5 0.0 1.5 5.5 30.0 11.3 18.7 23.2 1.5 0.0 1.5 5.8 30.0 11.2 18.8 23.3 1.4 0.0 1.4 6.0 30.0 11.1 18.9 23.3 1.4 0.0 1.4 6.3 30.0 11.0 19.0 23.4 1.4 0.0 1.4 6.5 30.0 10.8 19.2 23.5 1.3 19.8 18.5 6.8 30.0 10.6 19.4 23.6 1.3 0.0 1.3 7.0 30.0 10.4 19.6 23.8 1.2 0.0 1.2 7.3 30.0 10.1 19.9 23.9 1.2 0.0 1.2 7.5 30.0 9.8 20.2 24.1 1.1 0.0 1.1 7.8 30.0 9.5 20.5 24.3 1.0 0.0 1.0 8.0 30.0 9.1 20.9 24.5 0.9 0.0 0.9 8.3 30.0 8.6 21.4 24.8 0.8 0.0 0.8 8.5 30.0 8.1 21.9 25.1 0.8 0.0 0.8 8.8 30.0 7.5 22.5 25.5 0.6 0.0 0.6 9.0 30.0 6.8 23.2 25.9 0.5 0.0 0.5 9.3 30.0 6.0 24.0 26.4 0.4 0.0 0.4 9.5 30.0 5.0 25.0 27.0 0.3 0.0 0.3 9.8 30.0 3.5 26.5 27.9 0.1 0.0 0.1 10.0 30.0 0.0 30.0 30.0 0.0 0.0 0.0 Note1: Earth Curvature is based on a spherical Earth model w ith a nominal radius of 6371Km and a typical K-factor of Opti cal LOS 1st Fr esnel Radi o LOS 8.42 6.00 4.95 4.32 3.91 3.61 1.06 2.10 2.00 0.60 0.48 2.76 2.70 2.65 2.60 1.67 2.54 2.53 2.52 2.51 2.52 2.53 2.54 2.57 2.60 0.94 2.70 2.76 2.84 2.94 3.05 3.20 3.38 3.61 3.91 4.32 4.95 6.00 8.42 1.33. Ear th Cur vatur e Obstr ucti ons 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 0.0 2.0 4.0 6.0 8.0 10.0 D i s t a nc e ( k m) © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-12 Select the Grounding Location for both the MDS FOUR.9 Series ODU and SDIDUTM: The MDS FOUR.9 Series must be properly grounded in order to protect it and the structure it is installed on from lightning damage. This requires Grounding all ODUs as specified by supplier Grounding all SDIDUTM to the rack. • Confirm the Presence of DC Power for the MDS FOUR.9 Series SDIDUTM. • Ensure Building Aesthetics: Ensure that the ODU can be mounted so that it is aesthetically pleasing to the environment and to the property owner. Aesthetics must be approved by the property owner and the network engineer. • Take Site Photographs • Sketch the Site 3.6.3 Critical System Calculations 3.6.3.1 Received Signal Level (RSL) and Link Budget The received signal level (RSL) can be estimated using the following formula: RSL (dBm) = PTX + GTX ANT – LPath + GRX ANT Where: PTX is the transmitter output power (in dBm) GTX ANT is the gain of the transmit antenna (in dB) GRX ANT is the gain of the receive antenna (in dB) LPath is the Path loss, defined by: LP (dB) = 36.6 + 20log10(F*D) Where: F is the Frequency in MHz (4900 GHz), D is the Distance of path in miles This link budget is very important in determining any potential problems during installation. expected RSL and measured RSL should be close (+/- 5 to 10 dB) 3.6.3.2 The Fade Margin Calculation The fade margin is the difference between the actual received signal and the MDS FOUR.9 Series Radio’s threshold for the modulation mode selected. The fade margin can be used to determine availability and should be at least 10 dB. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3.6.3.3 3-13 Availability Calculation Availability of the microwave path is a prediction of the percent of time that the link will operate without producing an excessive BER due to multipath fading. Availability is affected by the following: • Path length • Fade margin • Frequency • Terrain (smooth, average, mountainous, valleys) • Climate (dry, temperate, hot, humid) Depending on the type of traffic carried over the link and the overall network design redundancy, fade margin should be included to support the desired availability rate. Critical data and voice may require a very high availability rate (99.999% or 4.9 minutes of predicted outage per year). To improve availability, the fade margin can be increased by shortening the path length, transmitting at a higher power level, or by using higher gain antennas. Availability can be computed using the following formula, which is known as the Vigants Barnett Method. Availability = 100 × (1 – P) P = 2.5 × 10-9 × C × F × D3× 10(-FM/10) Where F is the frequency in MHz (4900 MHz) D is the distance in miles FM is the fade margin in dB C is the climate/terrain factor as defined below: Humid/Over Water: C = 4 (worst case channel) Average Conditions: C = 1 Dry/Mountains: C = 0.25 (best case channel) Example: Assume 21 dB fade margin, over 5 miles with average climate/terrain, at 4.9 GHz. The availability comes out to be 99.9986. This corresponds to the link being unavailable for 7.6 minutes per year. 3.6.4 Frequency Plan Determination When configuring MDS FOUR.9 Series units in a point-to-point or consecutive point configuration, careful engineering of the MDS FOUR.9 Series frequency plans and antenna locations should be performed in order to minimize potential interference between nearby radios. Nearby radios should operate on different frequencies, transmitting in the same band (high side or low side). © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-14 When designing multi-radio configurations, antenna size, antenna polarization, and antenna location are critical. The frequency plan must be selected based on desired data rate and expected link conditions. In a high interference environment or with lower gain antennas, higher bandwidth, more robust modulation formats must be employed. The available frequency plans are illustrated in Figure 3-3. The channel assignments shown in the figures correspond to the channel numbers entered via the graphical user interface (GUI) or SNMP. 1 Channel Operation, 30MHz Bandwidth A Tx B Rx A Rx B Tx Diplexer F, MHz 5270 5250 1A Tx 1B Rx 2 Channel Operation, 20MHz Bandwidth 2A Tx 2B Rx 5330 1A Rx 1B Tx Diplexer 5350 2A Rx 2B Tx F, MHz 5250 5320 5280 5260 5340 5350 3 Channel Operation, 13.3MHz Bandwidth 1A Tx 1B Rx 2A Tx 2B Rx 3A Tx 3B Rx Diplexer 1A Rx 1B Tx 2A Rx 2B Tx 3A Rx 3B Tx F, MHz 5250 5257 5270 5283 5317 5330 5343 5350 Figure 3-3. MDS FOUR.9 Series Channel 4.9 GHz Frequency Plan (Preliminary Artwork—Need to change to 4.9 GHz frequencies—Greg?) 3.6.5 Antenna Planning The ODU must be used with an external antenna. adequate link performance for most applications. The choice of antenna should provide Larger antennas have the advantage of providing narrower beamwidths and high isotropic gain, which yields better link performance (higher fade margin, better availability), and improves immunity to spatial interference (due to the smaller beamwidths). However, larger antennas are more costly to purchase and install than smaller antennas and in some cases, they require special equipment for installation due to narrower beamwidths. They are also more easily affected by wind. Only directional antennas can be used with MDS FOUR.9 Series radios. Consult factory for antenna manufacturer options. 1. Select where the cable will enter the building from the outside. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-15 2. Determine the length of cable required. Allow three extra feet on each end to allow for strain relief, as well as any bends and turns. 3.6.6 ODU Transmit Power Setup Setting the ODU transmit power is conditional on the band and application. The installer of this equipment is responsible for proper selection of allowable power settings. If there are any questions on power settings refer to your professional installer in order to maintain the FCC legal ERP limits. The SDIDUTM employs spectrally efficient shaped Quadrature Amplitude Modulation (QAM). This waveform is not a constant envelope waveform. Therefore, the average power and peak power are different. The difference in peak and average power depends on the constellation type and shaping factor, where spectral efficiency such as more constellation points or lower shaping factor leading to peak powers higher than average powers. The peak power is typically 5-7 dB greater than the average power in the SDIDUTM, and never exceeds 7 dB. Regulatory requirements are usually based on peak EIRP which is based on peak power and antenna gain. 3.6.6.1 4.9 GHz Band In the 4.9 GHz Public Safety band the peak EIRP (Effective Isotropic Radiated Power) is limited to +57.8 dBm at the antenna for bandwidths up to 15 MHz and is reduced for narrower bandwidths in accordance with FCC Part 90.1215. The ODU must therefore be adjusted so that the station does not exceed the allowable limit. The installer is responsible during set up of transmit power to not exceed FCC limits on transmission power. These maximum power levels are provided in Table 3-2 for various antenna configurations, along with the operational bandwidths. Note that though regulatory limits are stated in terms of peak power, the system transmit power levels are calibrated as averaged power readings. Average power is used for link calculations. Therefore the levels provided in table 3-2 are average power levels that have been certified to correspond with the maximum peak EIRP allowed. EIRP is calculated for link budget with external antennas as, EIRP(avg) dBm = External Antenna Gain (dBi) + 23 dBm 3.6.6.1.1 ODU with External Antenna When using external antennas with gains greater than 23 dBi, the transmit power must be reduced in dB from that given in Table 3-1 by the antenna gain difference above 23 dBi for the mode that is being used. For example, using a 6 foot dish antenna with 37 dBi gain, the output power would be dropped by Antenna Gain (External) – 23 dBi = Antenna Gain Difference 37.6 dBi – 23 dBi = 14.6 dB © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-16 For mode 100FE1 (single channel configuration with 30MHz emission bandwidth) the power would be lowered from Tx Power – Antenna Gain Difference = Tx Power (External Ant) +5 dBm – 14.6 dB = -9.6 dBm (-10 dBm). Table 3-1 also presents transmit power settings for various antenna dish sizes. For link budget, EIRP(Avg) dBm = 37 dBi + Tx Power Setting (dBm). Table 3-2. Maximum Power Settings for 4.9GHz Public Safety Band Operation (US). Antenna Diameter Antenna Gain, dBi* (example) Maximum Tx Power Setting, dBm EIRP 8 foot dish 39.5 17 56.5 6 foot dish 36.1 21 57.1 4 foot dish 33.1 23 56.1 3 foot dish 30.5 23 53.5 2 foot dish 27.1 23 50.1 * Note: Many antenna manufacturers rate antenna gain in dBd (dB referred to a dipole antenna) in their literature. To convert to dBi, add 2.15 dB. Power settings for other modes of operation can be easily extrapolated from Table 3-2. For link budget calculations, EIRP(Avg) dBm= Antenna Gain (dBi) + Tx Power Setting (dBm). Though transmitter radiated power is limited in the 4.9 GHz band regardless of antenna size, the receiver benefits from gain of larger antennas. 3.6.7 Documenting a Site Evaluation Use the site evaluation form provided on the following pages to document the results of your site evaluation. Optimally, this complete site form would be stored with the SDIDUTM for future reference. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-17 Site Evaluation Form Address Site Engineer Contact Person Phone Site No Site Agent Site Type ODU Roof Location Latitude Longitude Example Information Mapping Datum (ex. NDA27) ODU ODU# Information Information Clear Line of Sight Yes Mounting Method Wall or Pole FCC Compliance Yes Collocation Aesthetics ODU Azimuth 60 degrees GPS Reading 80 21' 48" Roof Requirements Cable Lengths Alarm Interconnect Cable 250 feet Grounding/Lighting Instructions Photographs* Photo 1 Photo 2 Photo 3 Sketches** Sketch 1 Sketch 2 Recommendations for Site Photographs and Sketches *Photographs **Sketches Photo 1 - ODU mounting location Sketch 1- Roof and cable route to entry point Phone 2 - View from the ODU mounting location to the link partner Sketch 2 - Details for grounding and lighting protection Photo 3 - IDU location Sketch 3 - IDU room and cable routes from entry port © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-18 Site Evaluation Parameters Example Information Tx and/or Rx Information Information Information Information Tx/Rx Distance from ODU Colocated Information 2.1 GHz Frequency Owner 5 feet Sprint PCS Azimuth 210 degrees Elevation Antenna Type 2 degrees downtilt Power Power 14W Parameters Example Information IDU room Identified Space for cabinet SDIDUTM Information PCS Source Phone line Yes Yes Need to install 48 VDC available? Cables Yes Confirm cables Take Photo 3 Sketch 3 Front View Top View Side View Equipment Cabinet Batteries Note Indoor Space Equipment Dimensions © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-19 3.7 Installation of the MDS FOUR.9 Series The following sections provide installation guides for: • SDIDUTM Installation • ODU Installation 3.7.1 Installing the MDS FOUR.9 Series Software Defined IDUTM The MDS FOUR.9 Series SDIDUTM can be installed in the following three options: 1. Table top or cabinet 2. Wall mount 3. Rack mount The MDS FOUR.9 Series SDIDUTM should be: • Located where you can easily connect to a power supply and any other equipment used in your network, such as a router or PC. • In a relatively clean, dust-free environment that allows easy access to the rear grounding post as well as the front panel controls and indicators. Air must be able to pass freely over the chassis. • Accessible for service and troubleshooting. • Protected from rain and extremes of temperature (it is designed for indoor use). 3.7.1.1 Installing on a Table Top or Cabinet The MDS FOUR.9 Series SDIDUTM can be placed on a tabletop or cabinet shelf. In order to prevent possible disruption, it is recommended to use a strap to secure the SDIDUTM. 3.7.1.2 Installing on a Wall An installation option for the SDIDUTM is mounting the unit to a wall. If the wall mount option is being considered, plan to position the MDS FOUR.9 Series SDIDUTM at a height that allows LEDs, the connectors on the front panel, and the rear grounding post to be visible at all times and easily accessible. Also, including plastic clamps to support and arrange the ODU/ SDIDUTM Interconnect Cable should also be considered. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3.7.1.3 3-20 Installing in a Rack To rack-mount the SDIDUTM, use the supplied mounting brackets to secure the chassis to a 19 inch rack cabinet. As shown in Figure 3-5, the brackets can be attached to the front sides of the enclosure. An optional 21 inch rack mount kit is also available (consult factory for details). 179H176H Figure 3-5. MDS FOUR.9 Series SDIDUTM Dimensions 3.7.2 Installing the MDS FOUR.9 Series ODU The MDS FOUR.9 Series ODU is intended for mounting on either a pole or antenna mast. Each site must be assessed for the mounting method, location, and height. After defining the mounting location and height for the MDS FOUR.9 Series ODU, re-confirm the line of sight. When operating a 1+1 configured SDIDU™, i.e. an SDIDU™ with two power supplies and two modem modules installed, in 1+0 mode, the ODU must be connected to the modem in the bottom slot. If the ODU is connected to the modem in the top slot, the SDIDU™ will not communicate with the ODU, and a link cannot be established. 3.7.2.1 Installing the Mounting Poles First install the mounting poles, on which you will mount the MDS FOUR.9 Series ODU. It is important to note the direction in which the ODU will point when installing the mounting pole. The mounting pole must be mounted in a vertical position. Failure to do so may result in improper alignment of the ODU. Vertical tilt of the ODU is accomplished from the tilt mounting bracket. The mounting pole must be grounded. Now that you have installed the mounting pole, you are ready to install the MDS FOUR.9 Series ODU onto the mounting poles. Reference Figure 3-6 through Figure 3-9. 180H177H © 2006 Microwave Data Systems Inc. All Rights Reserved. 181H178H MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-21 Figure 3-6. Mounting Parts for the MDS FOUR.9 Series ODU 1. Remove the pole mount portion of the tilt bracket from the ODU by loosening the middle bolts and removing the top and bottom bolts on each side. 2. Mount the tilt bracket to the mounting pole using the U-Bolts and nuts. Insert the U-bolts around the pole and through the holes in the tilt bracket. Install a washer and nut to each side of the threaded U-bolt and hand tighten. Repeat this step for the second U-bolt. 3. Place the MDS FOUR.9 Series ODU on the mating half of the tilt bracket connected by the two center bolts. 4. Add the remaining four bolts to the tilt bracket and tighten securely. 5. Manually point the antenna in the direction of the link partner. Figure 3-7. MDS FOUR.9 Series ODU Rear View © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-22 Figure 3-8. Tilt Bracket Figure 3-9. MDS FOUR.9 Series ODU with Mounted Tilt Bracket 3.7.3 Routing the ODU/ SDIDUTM Interconnect Cable 1. Select where the cable will enter the building from outside. 2. Determine the length of cable required. Allow three extra feet on each end to allow for strain relief, as well as any bends and turns. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-23 3. Route the cable. The SDIDUTM is equipped with TNC female connector on the front of the chassis. Depending on the ODU type, it will be equipped with either a N-type or TNC female connector at its interconnecting port. A length of coaxial cable (such as Times Microwave Systems LMR-400, LMR-300 or LMR-200) fitted with the appropriate N-type or TNC male connectors is required to connect the ODU to the SDIDUTM. This cable assembly may be supplied in fixed lengths with the digital radio. Bulk coaxial cable of equivalent specification may also be used, with terminating connectors applied during cable installation. Based on an evaluation of the cable routing path, pull the ODU/SDIDUTM Interconnect cable from one unit to the other, utilizing cable trays, ducts, or conduit as required. Take care that the ODU/ SDIDUTM Interconnect cable is not kinked or damaged in any way during installation. Be sure to protect the TNC connectors from stress, damage and contamination during installation (do not pull the cable by the connectors). If multiple ODU/ SDIDUTM Interconnect cables are to be installed along the same route, the cables should all be pulled at one time. Be sure the installed cable does not have any bends that exceed the specified cable bend radius. The ODU/ SDIDUTM Interconnect cable should be adequately supported on horizontal runs and should be restrained by hangers or ties on vertical runs to reduce stress on the cable. Outside the building, support and restrain the cable as required by routing and environmental conditions (wind, ice). The MDS FOUR.9 Series ODU/SDIDUTM and interconnection must be properly grounded in order to protect it and the structure it is installed on from lightning damage. This requires that the ODU, any mounting pole or mast and any exposed interconnect cable be grounded on the outside of the structure. The SDIDUTM must be grounded to a rack or structure ground that also has direct path to earth ground. The ODU must be directly connected to a ground rod or equivalent earth ground. The ODU/ SDIDUTM interconnect cable should also be grounded at the ODU, where the cable enters the structure and at intermediate points if the exposed cable run is long (typically at intervals of 100 ft), with the cable manufacturer’s grounding kits. Lightning protection devices used with the interconnect cable must be appropriate for the transmission of the interconnect signals (DC to 350 MHz). Provide a sufficient but not excessive length of cable at each end to allow easy connection to the ODU and SDIDUTM without stress or tension on the cable. Excessive cable length, especially outdoors, should be avoided to minimize signal attenuation and provide a more robust and reliable installation. If installing using bulk coaxial cable, terminate the ODU/ SDIDUTM Interconnect cable at each end with a TNC male connector on the SDIDUTM side and either a Ntype or TNC male connector on the ODU side that is appropriate for the cable type. Use of connectors, tools and termination procedures specified by the cable manufacturer is recommended. Once the cable has been installed but before connection has been made to either unit, a simple DC continuity test should be made to verify the integrity of the installed cable. A DC continuity tester or digital multimeter may be used to verify a lack of DC continuity between the cable center conductor and outer conductor, with the opposite end of the cable unconnected. With a temporary test lead or shorting adapter connected to one end of the cable, DC continuity should be verified between the center and outer conductors at the opposite end. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-24 3.8 Quick Start Guide 3.8.1 Materials Required 1. Power supply (-48 V DC @ 2 Amps) OR optional AC/DC power supply and power cable (A Phoenix Contact P/N 17 86 83 1 connector is provided) 2. Digital voltmeter with test leads and BNC connector (optional, for ODU alignment). 3. SDIDUTM Serial Cable (Optional) 4. Computer with networking capability, consisting of either: Laptop computer and Ethernet card with any necessary adapters and a Cat-5 Ethernet regular or crossover cable or Networked computer and an additional Ethernet cable providing access to the network. With the following system requirements: Minimum: • Pentium II 400MHz • 128MB RAM • 30MB available hard drive space • Windows 98, Windows NT, Windows 2000, or Windows XP • Internet Explorer 5.5 (available at http://www.microsoft.com) and above or Mozilla Firefox 1.0.6 (available at http://www.firefox.com) with default settings. • Sun Java JVM 1.5.0 or above (available at http://www.java.com) Recommended: • Pentium III 500MHz • 256 RAM • 30MB available hard drive space • Windows 98SE, Windows NT, Windows 2000, or Windows XP • Internet Explorer 5.5 (available at http://www.microsoft.com) and above or Mozilla Firefox 1.0.6 (available at http://www.firefox.com) with default settings. • Sun Java JVM 1.5.0 or above (available at http://www.java.com) 66H66H 67H67H 68H68H 69H69H 70H70H 71H71H 5. Site engineering folder with site drawings, or equivalent SDIDUTM configuration information 6. 1/8” slotted screwdriver 3.8.2 Grounding the ODU 1. Place the grounding rod so as to allow for the shortest possible path from the grounding cable to the ODU. 2. Drive the grounding rod into the ground at least eight inches from the ground surface. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-25 3. Attach a grounding clamp to the grounding rod. You will use this clamp to attach grounding wires for both the ODU and SDIDUTM, reference Figure 3-10. 182H179H Figure 3-10 Ground Connections to ODU 4. Connect a ground lug to one end of the grounding wire. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-26 5. Remove one of the lower mounting screws of the mounting pole. Insert a screw through the grounding lug terminal and re-install it to the mounting pole. 6. Attach the grounding wire to the clamp on the grounding rod. If necessary, use wire staples to secure the grounding wire to the outside wall. 3.8.3 Grounding the SDIDUTM 1. The SDIDU™ should be able to be connected to a system or building electrical ground point (rack ground or power third-wire ground) with a cable of 36” or less. 2. Connect the grounding wire to either grounding point on the front panel. Use 6-32x5/16 maximum length screws (not provided) to fasten the lug of the grounding cable. 3. Connect the other end of the ground to the local source of ground in an appropriate manner. 3.8.4 Connecting the SDIDUTM to the PC and Power Source 1. Using the supplied power cable connector, pin 2 (labeled -V) should be connected to the power supply terminal supplying -48 V dc, while pin 1 (labeled RET) should be connected to the power supply return. Refer to Figure 3-11. Use of a power supply with an inappropriate ground reference may cause damage to the SDIDUTM and/or the supply. 183H180H Figure 3-11. SDIDUTM DC Power Cable Connector 2. Connect the SDIDUTM power cable to the -48 V dc power supply, and place the voltmeter probes on the unconnected SDIDUTM end of the power cable, with the positive voltmeter probe on pin 2 (-V) of the cable connector and the negative probe on pin 1(RET). The connector terminal screw heads may be used as convenient monitor points. Refer to Figure 3-11. 184H181H 3. Turn on the –48 V dc supply. Verify that the digital voltmeter reads between -44 V dc and -52 V dc when monitoring the cable points specified above. Adjust the power supply output voltage and/or change the connections at the power supply to achieve this reading. 4. Turn the -48 V dc supply off. 5. Plug the SDIDUTM power cable into the SDIDUTM front panel DC Power connector (DC Input). Place the voltmeter probes on the cable connector terminal screw heads as per © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-27 step 2 above. Refer to Figure 3-11. Note that the MDS FOUR.9 Series SDIDUTM does not have a power on/off switch. When DC power is connected, the digital radio powers up and is operational. There can be up to 320 mW of RF power present at the antenna port. The antenna should be directed safely when power is applied. 185H182H 6. Turn on the -48 V dc power supply, and verify that the reading on the digital voltmeter is as specified in step 3 above. 7. Connect the SDIDUTM to the laptop computer, using a Cat-5 Ethernet cable or connect the SDIDUTM to a computer network, using a Cat-5 Ethernet cable. Connect the Ethernet cable to the NMS 1 or 2 connector on the SDIDUTM front panel. Refer to Figure 3-12 for the SDIDUTM front panel connections. 186H183H Figure 3-12. MDS FOUR.9 Series-SB, 1+1 Protection: SDIDUTM Front Panel Connections 3.8.5 SDIDUTM Configuration Although basic configuration of the MDS FOUR.9 Series SDIDUTM does not require a connection to the ODU, it is recommended that the ODU and SDIDUTM are connected prior to configuring the SDIDUTM. A connection to the ODU must be established prior to running the Link Configuration process (section 5.2) in order to configure ODU related parameters. 3.8.5.1 Setting the IDU IP Address 1. The PC’s network configuration must be set with the parameters provided at the end of this guide. 2. The IDU should be accessible from your PC at the default IP address provided at the end of this guide. A network ‘ping’ can be done to verify connectivity to the IDU. 3. Start web browser and use the SDIDUTM default IP address as the url. 4. Log in at the login prompt. The username and password are provided at the end of this guide. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-28 5. The GUI includes a navigation menu in the left frame. If this navigation menu is not visible, make sure the Java environment is properly installed and active. In the navigation menu, select Administration, then Network Configuration, and then General. The IP address, IP Netmask, and IP Gateway are shown. 6. Enter the new IP address, IP Netmask, and IP Gateway. The gateway must be in the same subnet as the IP address for proper operation. Click “Update” to change the values. 7. To verify the new IP address, change the PC's network configuration to be on the same subnet as the new IP address set in the unit and a network 'ping' may be performed to the new address. 8. To continue using the GUI, point the web browser to the new IP address. 3.8.5.2 Link Configuration 1. Start the SDIDUTM GUI. 2. Use the frame on the left side of the window to navigate to “Link Configuration”, then “Radio Link.” 3. Select the subcategory “Link Configuration.” 4. Select the operating mode. If the SDIDUTM has one modem installed and is connected to one ODU, select standard. If the SDIDUTM has two modems installed and is connected to two ODUs, select 1+1 diversity or 1+1 non-diversity for a protected link or east-west for a 2+0 ring configuration. 5. Follow the wizard located here to enter the rest of the required settings. 3.8.5.3 Setting SDIDUTM Site Attributes 1. Start the SDIDUTM GUI. 2. In the navigation menu, select Administration, then Device Information, and then Device Names. 3. Enter the Owner, Contact, Description, and Location. These values are not required for operation, but will help keep a system organized. 3.8.5.4 CLI Access via NMS Ethernet The CLI may be accessed via NMS Ethernet after connecting and configuring the PC as described in the previous section. Then using a Telnet client, telnet to the SDIDUTM IP address. You will be prompted for a username and password. Use the username and password supplied at the end of this guide. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3.8.5.5 3-29 CLI Access via Serial Port The CLI for configuring/monitoring the SDIDUTM may be accessed via the front-panel serial port. Table 3-3 shows the pinout for constructing a DB-9 to HD-15 cable. 187H184H Table 3-3: Serial Cable Pinout DB-9 Pin HDB-15 Pin The serial port parameters are show in Table 3-4. 188H185H Table 3-4: Serial Port Parameters Parameter Speed Bits Stop-Bits Parity Flow-Control Value 38400 None None After powering-on the SDIDUTM, the CLI may be accessed by connecting the serial cable between the PC and the SDIDUTM, launching and configuring a terminal program (e.g. Hyperterm) and pressing the enter key. You will be prompted for a username and password, which are supplied at the end of this guide. 3.8.6 ODU Antenna Alignment To use the built-in tuning of the ODU antenna, a complete link is required, with both ends of the link roughly pointed at each other, and transmitting. Once the links are roughly pointed, connect the voltmeter to the RSSI (Receive Signal Strength Indication) BNC connector seen on the ODU. This mode outputs 0 to +3 Volts. Adjust the antenna for maximum voltage. The RSSI voltage is linearly calibrated from 2.5 Volts for maximum RSL (received signal level) at –20 dBm to 0Volts for minimum RSL at -90 dBm. This mapping characteristic is plotted below in Figure 3-13. 189H186H © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-30 RSSI - Mapped Voltage Output RSSI Output (V) -100 -80 -60 -40 -20 Received Signal Level (dBm ) Figure 3-13. ODU RSSI Output vs. Received Signal. 3.8.7 Quick Start Settings PC Network Configuration The Web GUI may be accessed via NMS by connecting a CAT5 patch cable between the SDIDUTM front-panel NMS port and a PC. The PCs network interface must be configured to an open IP address within the same subnet. For the default SDIDUTM configuration, the IP address of the PC needs to be 192.168.0.x, where x (between 2 and 253) provides an available IP address. DHCP may also be used to set the PC IP address if a DHCP server is configured on the same subnet. SDIDUTM Default IP Address Parameter IP Address Netmask Gateway Value 192.168.0.1 255.255.255.0 192.168.0.254 After configuring the PCs network interface, a web browser may be launched and the following URL entered to access the Web GUI: http://192.168.0.1/ Username and Password A dialog box will show requesting a username and password: • • User: administrator Pass: d1scovery © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 3-31 3.9 Documenting MDS FOUR.9 Series Configuration Use the MDS FOUR.9 Series configuration form provided at the end of this section, or a similar form, to document the results of the SDIDUTM configuration procedure. Optimally, this complete site form would be stored with the SDIDUTM for future reference. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A AB-Full Access Digital Radio Configuration Form Link ID Radio Type (A/B) A=Low band, Horizontal polarization, odd serial number B=High band & Vertical polarization, even serial number Radio ID # Radio S/N Site Name Network Administration - Radio Addresses Link Administration - Radio Commissioning: Near IP: Far IP Routing Rain Model F requency Net Mask: IP EMS 1 Grade of Service NTP: IP EMS 2 Rain Region Gateway: IP EMS 3 IP EMS 4 SNMP Community Names TX RX Link Distance GPS Location Distance (meters) Trap: Super User Read/Write Read: OR Radio Type (A/B) Radio ID# Near Latitude deg min sec Near Longitude deg min sec Far Latitude deg min sec Far Longitude deg min sec Radio S/N Site Name Network Administration - IFU Addresses Link Administration - Radio Commissioning: Near IP: Far IP Routing Rain Model F requency Net Mask: IP EMS 1 Grade of Service NTP: IP EMS 2 Rain Region Gateway: IP EMS 3 IP EMS 4 SNMP Community Names TX RX Link Distance GPS Location Distance (meters) Trap: Super User Read/Write Read: OR Near Latitude deg min sec Near Longitude deg min sec Far Latitude deg min sec Far Longitude deg min sec 4 Summary Specifications Parameter Characteristic System Capacity 50 Mbps Ethernet 1-16 T1/E1 Various combinations of above Frequency Range Output Power – Average* 4.9475 to 4.9825 GHz +5 to 23 dBm (at antenna port) Output Power – Peak* (at antenna port) Input Sensitivity Maximum Input Power Modulation Channelization 17.1 dBm (Low Power) 24.4 dBm (High Power) -84 dBm (or higher, based on selected mode) -20 dBm QPSK to 64-QAM 12.5, 16.7 MHz Radio Interfaces External Antenna N Type Female TM TNC Female SDIDU /ODU Link RSSI BNC Female Data Interfaces Payload Ethernet 100Base-Tx RJ-45 2 T1/E1 RJ-48C Female (2) 14 T1/E1 Molex High-Density 60-pin SNMP 10Base-T/100Base-Tx RJ-45 Female Control Network Management SNMP, web/http browser NMS Connector 10Base-T/100Base-Tx Voice Orderwire RJ-48C Auxiliary Data (64 kps) RJ-48C © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 4-2 Encryption Proprietary, AES (optional) Alarm Port 2 Form C (SPDT), 2 TTL Output, 4 TTL Input, DB-15HD Power/Environment DC Power -48 Volts +/-10%, <70 W SDIDUTM Operational Temperature -5 to 55 degrees C ODU Operational Temperature -30 to 55 degrees C SDIDUTM Humidity 0 to 95%, non-condensing ODU Humidity ODU Humidity Altitude Altitude Physical Dimensions SDIDUTM Size (WxHxD) 17.2 x 1.75 x 14.5 inches (43.7 x 4.5 x 36.0 cm) SDIDUTM Weight 7 lbs (3.12 Kg) TM SDIDU EIA Rack Mount 19 inch/48.2 cm, 1 rack unit ODU Size (W x H x D) 14.6 x 15.4 x 2.6 inches ODU Weight 15 lbs (6.8 Kgs) ODU Mounting/Installation Custom Bracket * For definitions of peak and average power, see Section 3.6.6 © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A 5 Front Panel Connectors 5.1 DC Input (Power) Connector PIN Two-pin male TYPE SIGNAL POWER Power supply return POWER -48 Vdc, nominal 5.2 Ethernet 100BaseTX Payload Connector 1-2 PIN RJ-45 Female TYPE SIGNAL INPUT RX+ INPUT RX- OUTPUT TX+ N/A N/A N/A N/A OUTPUT TX- N/A N/A N/A N/A 12 3 4 5 6 7 8 © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5-2 5.3 SONET Payload Connector Consult factor for Mini-IO Optical Module for availability. SC Duplex Female Fiber PIN TYPE OUT OUTPUT SONET OC-3 payload output (optical) INPUT SONET OC-3 payload input (optical) IN SIGNAL OUT IN 5.4 STM-1 Payload Connector Consult factor for Mini-IO Optical Module for availability. BNC Duplex TX PIN TYPE SIGNAL TX OUTPUT SDH STM-1 payload output (electrical) RX INPUT SDH STM-1 payload input (electrical) RX 5.5 DS-3/E-3/STS-1 Payload Connector BNC Duplex TX PIN TYPE SIGNAL TX OUTPUT DS-3/E-3/STS-1 payload output RX INPUT DS-3/E-3/STS-1 payload input RX © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5-3 5.6 NMS 10/100BaseTX Connector 1-2 RJ-45 Female PIN TYPE SIGNAL OUTPUT TX+ OUTPUT TX- INPUT RX+ N/A N/A N/A N/A INPUT RX- N/A N/A N/A N/A 12 3 4 5 6 7 8 5.7 Alarm/Serial Port Connector DB-15HD Female PIN TYPE OUTPUT 21 INPUT/ Output RS-232 RX/TX 31 OUTPUT/ Input RS-232 TX/RX OUTPUT TTL Alarm Output 4 N/A GROUND 62 N/A Alarm 1 Form C Contact Normally Open 72 N/A Alarm 1 Form C Contact Normally Closed 82 N/A Alarm 2 Form C Contact Common 0F0F 1F1F SIGNAL TTL Alarm Output 3 Pins 2 and 3 are hardware jumper configurable for DCE or DTE operation. Form C Contacts are hardware jumper configurable to emulate TTL outputs. © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5-4 PIN TYPE SIGNAL INPUT TTL Alarm Input 1 10 INPUT TTL Alarm Input 3 112 N/A Alarm 1 Form C Contact Common 122 N/A Alarm 2 Form C Contact Normally Open 132 N/A Alarm 2 Form C Contact Normally Closed 14 INPUT TTL Alarm Input 2 15 Input TTL Alarm Input 4 TYPE SIGNAL 5.8 ODU Connector PIN TNC coaxial female Center I/O 350 MHz TX IF / 140 MHz RX IF / -48 VDC Shield N/A Shield / Chassis GND 5.9 T1- Channels 1-2 Connector RJ-45 Female PIN TYPE SIGNAL INPUT RX+ INPUT RX- N/A GND OUTPUT TX+ OUTPUT TX- N/A GND N/A N/A N/A N/A 12 3 4 5 6 7 8 © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5.10 60-pin Molex 5-5 T1- Channels 3-16 Connector PIN TYPE SIGNAL OUTPUT T1 Channel 13 Transmit Tip OUTPUT T1 Channel 14 Transmit Tip OUTPUT T1 Channel 15 Transmit Tip OUTPUT T1 Channel 16 Transmit Tip OUTPUT T1 Channel 9 Transmit Tip OUTPUT T1 Channel 10 Transmit Tip OUTPUT T1 Channel 11 Transmit Tip OUTPUT T1 Channel 12 Transmit Tip OUTPUT T1 Channel 5 Transmit Tip 10 OUTPUT T1 Channel 6 Transmit Tip 11 OUTPUT T1 Channel 7 Transmit Tip 12 OUTPUT T1 Channel 8 Transmit Tip 13 OUTPUT T1 Channel 3 Transmit Tip 14 OUTPUT T1 Channel 4 Transmit Tip 15 NC NC 16 NC NC 17 OUTPUT T1 Channel 4 Transmit Ring 18 OUTPUT T1 Channel 3 Transmit Ring 19 OUTPUT T1 Channel 8 Transmit Ring 20 OUTPUT T1 Channel 7 Transmit Ring 21 OUTPUT T1 Channel 6 Transmit Ring 22 OUTPUT T1 Channel 5 Transmit Ring 23 OUTPUT T1 Channel 12 Transmit Ring © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5-6 PIN TYPE SIGNAL 24 OUTPUT T1 Channel 11 Transmit Ring 25 OUTPUT T1 Channel 10 Transmit Ring 26 OUTPUT T1 Channel 9 Transmit Ring 27 OUTPUT T1 Channel 16 Transmit Ring 28 OUTPUT T1 Channel 15 Transmit Ring 29 OUTPUT T1 Channel 14 Transmit Ring 30 OUTPUT T1 Channel 13 Transmit Ring 31 INPUT T1 Channel 16 Receive Tip 32 INPUT T1 Channel 15 Receive Tip 33 INPUT T1 Channel 9 Receive Tip 34 INPUT T1 Channel 14 Receive Tip 35 INPUT T1 Channel 10 Receive Tip 36 INPUT T1 Channel 13 Receive Tip 37 INPUT T1 Channel 11 Receive Tip 38 INPUT T1 Channel 4 Receive Tip 39 INPUT T1 Channel 12 Receive Tip 40 INPUT T1 Channel 3 Receive Tip 41 INPUT T1 Channel 5 Receive Tip 42 INPUT T1 Channel 8 Receive Tip 43 INPUT T1 Channel 6 Receive Tip 44 INPUT T1 Channel 7 Receive Tip 45 NC NC 46 NC NC 47 INPUT T1 Channel 7 Receive Ring 48 INPUT T1 Channel 6 Receive Ring © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5.11 USB Type A 5-7 PIN TYPE SIGNAL 49 INPUT T1 Channel 8 Receive Ring 50 INPUT T1 Channel 5 Receive Ring 51 INPUT T1 Channel 3 Receive Ring 52 INPUT T1 Channel 12 Receive Ring 53 INPUT T1 Channel 4 Receive Ring 54 INPUT T1 Channel 11 Receive Ring 55 INPUT T1 Channel 13 Receive Ring 56 INPUT T1 Channel 10 Receive Ring 57 INPUT T1 Channel 14 Receive Ring 58 INPUT T1 Channel 9 Receive Ring 59 INPUT T1 Channel 15 Receive Ring 60 INPUT T1 Channel 16 Receive Ring PIN TYPE SIGNAL OUTPUT +5V I/O -Data I/O +Data N/A GND USB © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 5.12 5-8 Voice Order Wire RJ-48C Female PIN TYPE SIGNAL N/A NC INPUT PTT N/A GND OUTPUT PO- OUTPUT PO+ INPUT TI- N/A GND N/A NC 12 3 4 5 6 7 8 5.13 Data Order Wire RJ-48C Female PIN TYPE SIGNAL OUTPUT TX Clock - OUTPUT TX Clock + OUTPUT TX Data - INPUT RX Data - INPUT RX Data + OUTPUT TX Data + INPUT RX Clock - INPUT RX Clock + 12 3 4 5 6 7 8 © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A 6 Appendix 6.1 Alarm Descriptions Alarm Affected Component Description LED to RED Alarm Code Severity Modem Fault Lower Modem The specified Modem card has indicated a fault. Fault detection is via reading Modem Hardware Status from MODEM during start-up and polling GPIO for MODEM fault indication. Polling interval 5 sec. N/A 11 Critical Modem Comm Failiure Lower Modem The Controller Card is unable to communicate with the specified Modem card. Modem Lower 12 Critical Modem Card Removed Lower Modem The specified Modem card has been removed from the IDU (only if the specified Modem card has been enabled for use). Fault detection via card-detect logic. N/A 13 Major Modem Card Installed Lower Modem The specified Modem card has been installed into the IDU (only if the specified Modem card is not enabled for use). Fault detection via card-detect logic. Alarm is cleared after 5 minutes. Modem Lower 14 Info Modem Unlock Lower Modem The demodulation functional components of the modem have lost lock to the incoming signal. The data received through the RF link is not valid. Fault detection via modem status polling. Polling interval: 1 sec. N/A N/A Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-2 Description LED to RED Alarm Code Severity RSL Low Lower Modem RSSI is approaching the minimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing RSSI value to threshold value in configuration table. Polling interval 5 sec. N/A N/A Major Synthesizer Unlock Lower Modem Modem synthesizer has unlocked. Fault detection via modem status polling. Polling is done in conjunction with Modem Unlock polling. N/A N/A Critical SNR Low Lower Modem The signal-to-noise ratio is below the minimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing Eb/N0 value to threshold value in configuration table. Polling interval 5 sec. N/A N/A Major Modem Fault Upper Modem The specified Modem card has indicated a fault. Fault detection is via reading Modem Hardware Status from MODEM during start-up and polling GPIO for MODEM fault indication. Polling interval 5 sec. N/A 16 Critical Modem Comm Failiure Upper Modem The Controller Card is unable to communicate with the specified Modem card. Modem Lower 17 Critical Modem Card Removed Upper Modem The specified Modem card has been removed from the IDU (only if the specified Modem card has been enabled for use). Fault detection via card-detect logic. N/A 18 Major © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-3 Description LED to RED Alarm Code Severity Modem Card Installed Upper Modem The specified Modem card has been installed into the IDU (only if the specified Modem card is not enabled for use). Fault detection via card-detect logic. Alarm is cleared after 5 minutes. Modem Upper 19 Info Modem Unlock Upper Modem The demodulation functional components of the modem have lost lock to the incoming signal. The data received through the RF link is not valid. Fault detection via modem status polling. Polling interval 1 sec. N/A N/A Critical RSL Low Upper Modem RSSI is approaching the minimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing RSSI value to threshold value in configuration table. Polling interval 5 sec. N/A N/A Major SNR Low Upper Modem The signal-to-noise ratio is below the minimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing Eb/N0 value to threshold value in configuration table. Polling interval 5 sec. N/A N/A Major Synthesizer Unlock Upper Modem Modem synthesizer has unlocked. Fault detection via modem status polling. Polling is done in conjunction with Modem Unlock polling. N/A N/A Critical Fan Failure Controller The Fan rotational speed is too low. (Controller card LED flashed red rather than orange). Fault detection via polling fan controller status. Polling interval 10 sec. Controller 21 Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-4 Description LED to RED Alarm Code Severity Controller Card Fault Controller The CPU has detected a fault in the controller card. (Controller card LED flashes red rather than orange). Fault detection via software. Controller 22 Critical Low Battery Voltage Controller The CPU has detected a lowbattery voltage condition. (Controller card LED flashes red rather than orange). Fault detection via software polling RTC via controller FPGA. Controller 23 Info Power Supply Fault Lower Power Supply The Power Supply card has indicated a fault. Fault detection via polling GPIO. Polling interval 5 sec. N/A 31 Critical Power Supply Card Removed Lower Power Supply The specified Power Supply card has been removed from the IDU. Fault detection via carddetect logic. N/A 32 Major Power Supply Fault Upper Power Supply The Power Supply card has indicated a fault. Fault detection via polling GPIO. Polling interval 5 sec. N/A 36 Critical Power Supply Card Removed Upper Power Supply The specified Power Supply card has been removed from the IDU. Fault detection via carddetect logic. N/A 37 Major Standard I/O Card Removed StdIO The Standard I/O card has been removed from the IDU. Fault detect via card-detect logic. N/A 41 Critical Ethernet Payload Disconnect StdIO There is no cable detected at either Ethernet payload on Standard I/O card (only if Ethernet mode enabled). Fault detection via polling of Ethernet PHY. Polling interval 5 sec. Standard I/O 42 Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-5 Description LED to RED Alarm Code Severity Framer Initialization Timeout StdIO There is an Initalization wait for Framer to turn ON the Framer Receiver side after turning ON the Modem/ODU. Fault detection via polling. Poll only after timeout to detect. Standard I/O 43 Critical Mini I/O Card Removed MiniIO The Mini I/O card has been removed from the IDU (only if Mini I/O card has been enabled for use). Fault detection via card-detect logic. Standard I/O 46 Critical Mini I/O Card Installed MiniIO The Mini I/O card has been installed into the IDU (only if Mini I/O card is noted enabled for use). Fault detection via card-detect logic. Alarm is cleared after 5 minutes. Standard I/O 47 Info Optional I/O Card Removed OptIO The Optional I/O card has been removed from the IDU (only if the Optional I/O card has been enabled for use). Fault detection via card-detect logic. N/A 26 Critical Optional I/O Card Installed OptIO The Optional I/O card has been installed into the IDU (only if the Optional I/O card is not enabled for use). Fault detection via card-detect logic. Alarm is cleared after 5 minutes. Optional I/O 27 Info © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm T1/E1 Channel Alarm Ch x Affected Component StdIO (1-16) OptIO (1732) 6-6 Description There is either no cable detected at the specified E1/T1 channel port on Standard I/O Card or there is an AIS condition detected (only for active T1/E1 channels). Fault detection via polling of LIUs on Standart I/O card and Optional I/O Card when installed. Polling interval 2 channels per 1 sec. Report of this alarm in the GUI/Syslog/Alarm history shall indicate whether this is a disconnect or AIS condition. LED to RED Alarm Code Standard I/O when 1-16 51-58 (1-16) Severity Critical 61-68 Optional I/O when 17-32 (1732) Turn LED orange rather than RED T1/E1 Test Mode StdIO The user has selected a T1/E1 test mode (loopback or Tx Data). This alarm shall be set when the user sets the testmode for any of the T1/E1 channels, and cleared when all T1/E1 channels are not in loopback and Tx Data is normal. N/A 59 Info BERT/LB/CW Test Mode StdIO This alarm shall be set when the user enables either BERT,, Loopback, or CW mode, and cleared when all BERT, Loopback and CW modes are disabled. N/A 69 Info ODU Fault Lower ODU The ODU has indicated a fault condition. Fault detection via polling of ODU or unsolicited message, if supported. Polling interval 5 sec. Polling done via API functional call. Report of this alarm in the GUI/Syslog/Alarm history shall indicate the fault code from the ODU. N/A 71 Critical ODU Comm Failure Lower ODU The IDU is unable to communicate with the ODU. This could be a problem with the ODU or a problem with the cable connecting the ODU to the IDU. N/A 72 Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-7 Description LED to RED Alarm Code Severity ODU Fault Upper ODU The ODU has indicated a fault condition or unsolicited message, if supported. Fault detection via polling of ODU. Polling interval 5 sec. Polling done via API function call. Report of this alarm in the GUI/Syslog/Alarm history shall indicate the fault code from the ODU. N/A 73 Critical ODU Comm Failure Upper ODU The IDU is unable to communicate with the ODU. This could be a problem with the ODU or a problem with the cable connecting the ODU to the IDU. N/A 74 Critical Protection Switch MODEM/OD This alarm shall be set when an AL1 command is received from the active MODEM/ODU, then cleared when an AL2 command is received from the standby MODEM/ODU. Report of this alarm in the GUI/Syslog/Alarm history shall indicate the fault code from the ODU, if received. N/A 75 Critical East ATPC Tx at Max Power ODU The IDU is unable to increase the Tx Power as requested by link partner due to maximum power being reached. Maximum power is specified in the configuration table. N/A 76 Info West ATPC Tx at Max Power ODU The IDU is unable to increase the Tx Power as requested by link partner due to maximum power being reached. Maximum power is specified in the configuration table. N/A 78 Info Link Fault IDU Failed to receive link heartbeat from link partner via Radio Overhead (ROH) channel. Fault detection via timeout counter, which is reset via reception of link heartbeat message. N/A 81 Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-8 Description LED to RED Alarm Code Severity Remote Fault IDU Link Partner IDU indicating it has a fault condition. Local IDU receives Link Partner Fault detection via Radio Overhead (ROH) channel message. N/A 82 Info Encryption Failure IDU Data is not being decrypted properly due to encryption key mismatch between link partners. Fault detection via software detection of unreadable ROH messages from link partner. N/A 83 Critical Encryption OneWay IDU Only one IDU has data encryption enabled. Fault detection via software messages to/from link partner. N/A 84 Major External Alarm 1 External The external Alarm 1 input has been activated. Fault detection via polling GPIO. Polling interval 1 sec. N/A 91 Info External Alarm 2 External The external Alarm 2 input has been activated. Fault detection via polling GPIO. Polling interval 1 sec. N/A 92 Info External Alarm 3 External The external Alarm 3 input has been activated. Fault detection via polling GPIO. Polling interval 1 sec. N/A 93 Info External Alarm 4 External The external Alarm 4 input has been activated. Fault detection via polling GPIO. Polling interval 1 sec. N/A 94 Info Remote IDU Alarm Link Partner IDU The link partner IDU has indicated an alarm condition via ROH. N/A 95 Major Remote IDU External Alarm 1 Link Partner External The link partner IDU has indicated via ROH its external alarm input 1 has been activated. N/A 96 Info © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-9 Description LED to RED Alarm Code Severity Remote IDU External Alarm 2 Link Partner External The link partner IDU has indicated via ROH its external alarm input 2 has been activated. N/A 97 Info Remote IDU External Alarm 3 Link Partner External The link partner IDU has indicated via ROH its external alarm input 3 has been activated. N/A 98 Info Remote IDU External Alarm 4 Link Partner External The link partner IDU has indicated via ROH its external alarm input 4 has been activated. N/A 99 Info STM Loss of Clock IDU The SDH/SONET clock has lost lock. Fault detection via polling of LIU. N/A Solid Critical STM RS_LOS IDU The SDH/SONET has a Loss of Signal Defect. Fault detection via polling of LIU. N/A Solid Critical STM RS_B1 IDU The SDH/SONET Mux/Demux has a B1 Defect. Fault detection via polling of RS_B1_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM RS_LOF IDU The SDH/SONET Mux/Demux has a Loss of Frame Defect. Fault detection via polling of RS_LOF_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM RS_OOF IDU The SDH/SONET Mux/Demux has a Out of Frame Defect. Fault detection via polling of RS_OOF_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-10 Description LED to RED Alarm Code Severity STM RS_TIM IDU The SDH/SONET Mux/Demux has a Trace Identifier Mismatch Defect. Fault detection via polling of RS_TIM_T bit in STM1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM MS-AIS IDU The SDH/SONET Mux/Demux has detected an AIS at the Multiplexer Level. Fault detection via polling of MS_AIS_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM MS-REI IDU The SDH/SONET Mux/Demux has detected a Remote Error at the Multiplexer Level. Fault detection via polling of MS_REI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM MS-RDI IDU The SDH/SONET Mux/Demux has detected an Remote Defect at the Multiplexer Level. Fault detection via polling of MS_RDI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM MS_B2 IDU The SDH/SONET Mux/Demux has a B2 Defect at the Multiplex level. Fault detection via polling of MS_B2_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM AU-AIS IDU The SDH/SONET Mux/Demux has detected an AIS at the AU Level. Fault detection via polling of AU_AIS_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-11 Description LED to RED Alarm Code Severity STM AU-LOP IDU The SDH/SONET Mux/Demux has detected an Loss of Pointer Defect at the AU Level. Fault detection via polling of AU_LOP_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM HPUNEQ x IDU The SDH/SONET Mux/Demux HP number ‘x’ is Unequipped. Fault detection via polling of HP_UNEQ_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM HP-TIM IDU The SDH/SONET Mux/Demux HP number ‘x’ has a Trace Identifier Mismatch. Fault detection via polling of HP_TM_TIM_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM HP-REI IDU The SDH/SONET Mux/Demux HP number ‘x’ has a Remote Error Indication. Fault detection via polling of HP_REI_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM HP-RDI IDU The SDH/SONET Mux/Demux HP number ‘x’ has a Remote Defect Indication. Fault detection via polling of HP_RDI_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-12 Description LED to RED Alarm Code Severity STM HP-PLM IDU The SDH/SONET Mux/Demux HP number ‘x’ has a Path Identifier Mismatch. Fault detection via polling of HP_PLM_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM HP_B3 x IDU The SDH/SONET Mux/Demux HP number ‘x’ has a CRC Error. Fault detection via polling of HP_B3_T bit in STM-1 Core. Where ‘x’ is the HP index. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM TU-LOM lkm IDU The SDH/SONET Mux/Demux TU number ‘x’ has a Loss of Multiframe. Fault detection via polling of TU_LOMF_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM TU-AIS lkm IDU The SDH/SONET Mux/Demux TU number ‘x’ has an AIS. Fault detection via polling of TU_AIS_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM TU-LOP lkm IDU The SDH/SONET Mux/Demux TU number ‘x’ has a Loss of Pointer Defect. Fault detection via polling of TU_LOP_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-13 Description LED to RED Alarm Code Severity STM LPUNEQ lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ is Unequipped. Fault detection via polling of LP_UNEQ_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Info STM LP-TIM lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Trace Identifier Mismatch. Fault detection via polling of LP_TM_TIM_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major STM LP-REI lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Remote Error Indication. Fault detection via polling of LP_REI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM LP-RDI lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Remote Defect Indication. Fault detection via polling of LP_RDI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM LP-PLM lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Path Identifier Mismatch. Fault detection via polling of LP_PLM_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide Alarm Affected Component 6-14 Description LED to RED Alarm Code Severity STM LP-RFI lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Remote Fault Indication. Fault detection via polling of LP_RFI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Critical STM LP-BIP2 lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a CRC Error. Fault detection via polling of LP_BIP2_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core. N/A Solid Major 6.2 Abbreviations & Acronyms AIS Alarm Indication Signal BER Bit Error Rate Codec Coder-Decoder CPU Central Processing Unit DB Decibel DBm Decibel relative to 1 mW DCE Data Circuit-Terminating Equipment DTE Data Terminal Equipment EIRP Effective Isotropic Radiated Power FCC Federal Communications Commission FEC Forward Error Correction FPGA Field Programmable Gate Array GPIO General Purpose Input/Output IF Intermediate frequency IP Internet Protocol LED Light-emitting diode © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A User Reference and Installation Guide 6-15 LOS Line of Sight MIB Management Information Base Modem Modulator-demodulator ms Millisecond NC Normally closed NMS Network Management System OAM&P Operations, Administration, Maintenance, and Provisioning OC-3 Optical Carrier level 3 ODU Outdoor Unit PCB Printed circuit board POP Point of Presence QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying RF Radio Frequency RSL Received Signal Level (in dBm) RSSI Received Signal Strength Indicator/Indication RX Receiver SDH Synchronous Digital Hierarchy SNMP Simple Network Management Protocol SNR Signal-to-Noise Ratio TM SDIDU Software Defined Indoor Unit (CarrierComm trademark) SONET Synchronous Optical Network STM-1 Synchronous Transport Module 1 TCP/IP Transmission Control Protocol/Internet Protocol TTL Transistor-transistor logic TX Transmitter © 2006 Microwave Data Systems Inc. All Rights Reserved. MDS FOUR.9 Series 05-4561A01, Rev. A IN CASE OF DIFFICULTY... MDS products are designed for long life and trouble-free operation. However, this equipment, as with all electronic equipment, may have an occasional component failure. The following information will assist you in the event that servicing becomes necessary. TECHNICAL ASSISTANCE Technical assistance for MDS products is available from our Technical Support Department during business hours (8:00 A.M.–5:30 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble/symptom(s) that you are experiencing. In many cases, problems can be resolved over the telephone, without the need for returning the unit to the factory. Please use one of the following means for product assistance: Phone: 585 241-5510 E-Mail: mailto:TechSupport@microwavedata.com FAX: 585 242-8369 Web: http://www.microwavedata.com/ FACTORY SERVICE Component level repair of radio equipment is not recommended in the field. Many components are installed using surface mount technology, which requires specialized training and equipment for proper servicing. For this reason, the equipment should be returned to the factory for any PC board repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating specifications. If return of the equipment is necessary, you will be issued a Service Request Order (SRO) number and return shipping address. The SRO number will help expedite the repair so that the equipment can be repaired and returned to you as quickly as possible. Please be sure to include the SRO number on the outside of the shipping box, and on any correspondence relating to the repair. No equipment will be accepted for repair without an SRO number. A statement should accompany the radio describing, in detail, the trouble symptom(s), and a description of any associated equipment normally connected to the radio. It is also important to include the name and telephone number of a person in your organization who can be contacted if additional information is required. The radio must be properly packed for return to the factory. The original shipping container and packaging materials should be used whenever possible. When repairs have been completed, the equipment will be returned to you by the same shipping method used to send it to the factory. Please specify if you wish to make different shipping arrangements. To inquire about an in-process repair, you may contact our Product Services Group at 585-241-5540 (FAX: 585-242-8400), or via e-mail at: ProductServices@microwavedata.com User Reference and Installation Guide 6-2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2006:08:06 13:26:06-07:00 Modify Date : 2006:08:06 13:26:06-07:00 Page Count : 88 Creation Date : 2006:08:06 20:26:06Z Mod Date : 2006:08:06 20:26:06Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : dw8 Metadata Date : 2006:08:06 20:26:06Z Creator : dw8 Title : Microsoft Word - Manual Rev. 1.docEXIF Metadata provided by EXIF.tools