GS Instech COVERCELL25K In-Building RF Repeater User Manual

GS Instruments Co., Ltd. In-Building RF Repeater Users Manual

Users Manual

Download: GS Instech COVERCELL25K In-Building RF Repeater User Manual
Mirror Download [FCC.gov]GS Instech COVERCELL25K In-Building RF Repeater User Manual
Document ID1032750
Application ID5aXAM+1/dZlu5FDECQUHgQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize38.14kB (476767 bits)
Date Submitted2008-11-19 00:00:00
Date Available2009-01-03 00:00:00
Creation Date2008-11-18 16:34:20
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2008-11-18 16:40:35
Document TitleMicrosoft Word - GST_CoverCell25K_Rev2Nov062008_.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: C2F7B0E8BFB5

FCC ID : U88-COVERCELL25K
ATTACHMENT E.
- USER MANUAL -
HCT CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R08-205
1/1
GSTeletech
CoverCell 25K Repeater
USERS MANUAL
November 1, 2008
Version 1.1
WARNINGS, CAUTIONS, AND GENERAL NOTES
This product conforms to FCC Part 15, Section 21 of the FCC (Federal
Communications Commission) rules. Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
Indicates a procedure or practice, which, if ignored, may result in damage to the system or a
system component. Do not perform any procedure preceded by a WARNING until you
thoroughly understand the described conditions (e.g., To reduce the risk of burn, allow hot
devices to cool before handling).
Convention Definition
Warning
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operating in a commercial environment.
This equipment generates, uses, and radiates radio frequency energy and, if not installed and
used in accordance with this operator’s manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at their expense.
Safety Considerations
When installing or using this product, observe all safety precautions during handling and
operation.
Failure to comply with the following general safety precautions and with
specific precautions described elsewhere in this manual violates the safety standards of
the design, manufacture, and intended use of this product. GSTeletech assumes no
liability for the customer's failure to comply with these precautions.
WARNING
WARNING calls attention to a procedure or practice, which if ignored, may result in
damage to the system or system component. Do not perform any procedure preceded by
a WARNING until described conditions are fully understood and met.
If You Need Help
If you need additional copies of this manual, or have questions about system options, or need help
with installation and using of the system, please contact GSTeletech’ Customer Support.
GSTeletech Inc. Customer Support
6900 College Boulevard, Suite 850
Overland Park, KS 66211, USA
Toll Free: 1-866-9 GST USA
Phone: 913 469 6699
bdelozier@gsteletechinc.com
Service
Do not attempt to modify or service any part of this product other than in accordance with
procedures outlined in this Operator's Manual. If the product does not meet its warranted
specifications, or if a problem is encountered that requires service, notify GSTeletech
customer support department.
warranty and repair policy.
Service will be rendered according the GSTeletech
The product shall not be returned without contacting
GSTeletech and obtaining a return authorization number from the Customer Support
department.
When returning a product for service, include the following information: Owner, Model
Number, Serial Number, Return Authorization Number (obtained in advance from
GSTeletech Customer Support Department), service required and/or a description of the
problem encountered.
The GSTeletech Quality Plan includes product test and inspection operations to verify the
quality and reliability of our products.
GSTeletech uses every reasonable precaution to ensure that every device meets
published electrical, optical, and mechanical specifications prior to shipment. Customers
are asked to advise their incoming inspection, assembly, and test personnel as to the
precautions required in handling and testing ESD sensitive components. Physical damage
to the external surfaces voids warranty.
These products are covered by the following warranties:
1.
General Warranty
GSTeletech warrants to the original purchaser all standard products sold by
GSTeletech to be free of defects in material and workmanship for the duration of
the warranty period of one (1) year from date of shipment from GSTeletech.
During the warranty period, GSTeletech obligation, at our option, is limited to repair
or replacement of any product that GSTeletech proves to be defective.
This
warranty does not apply to any product, which has been subject to alteration,
abuse, improper installation or application, accident, electrical or environmental
over-stress, negligence in use, storage, transportation or handling.
2.
Specific Product Warranty Instructions
All GSTeletech products are manufactured to high quality standards and are
warranted against defects in workmanship, materials and construction, and to no
further extent.
Any claim for repair or replacement of a device found to be
defective on incoming inspection by a customer must be made within 30 days of
receipt of the shipment, or within 30 days of discovery of a defect within the
warranty period.
This warranty is the only warranty made by GSTeletech and is in lieu of all other
warranties, expressed or implied, except as to title, and can be amended only by a
written instrument signed by an officer of GSTeletech. GSTeletech sales agents or
representatives are not authorized to make commitments on warranty returns.
In the event that it is necessary to return any product against the above
warranty, the following procedure shall be followed:
a.
Return authorization shall be received from the GSTeletech Customer
Support prior to returning any device. Advise the GSTeletech Customer
Support of the model, serial number, and the discrepancy. The device shall
then be forwarded to GSTeletech, transportation prepaid. Devices returned
freight collect or without authorization may not be accepted.
b.
Prior to repair, GSTeletech Customer Support will advise the customer of
GSTeletech test results and will advise the customer of any charges for
repair (usually for customer caused problems or out-of-warranty conditions).
If returned devices meet full specifications and do not require repair, or if
non-warranty repairs are not authorized by the customer, the device may
be subject to a standard evaluation charge. Customer approval for the
repair and any associated costs will be the authority to begin the repair at
GSTeletech.
Customer approval is also necessary for any removal of
certain parts, such as connectors, which may be necessary for GSTeletech
testing or repair.
c.
Repaired products are warranted for the balance of the original warranty
period, or at least 90 days from date of shipment.
3.
Limitations of Liabilities
GSTeletech liability on any claim of any kind, including negligence, for any loss or
damage arising from, connected with, or resulting from the purchase order,
contract, or quotation, or from the performance or breach thereof, or from the
design, manufacture, sale, delivery, installation, inspection, operation or use of any
equipment covered by or furnished under this contract, shall in no case exceed the
purchase price of the device which gives rise to the claim.
EXCEPT AS EXPRESSLY PROVIDED HEREIN, GSTELETECH MAKES NO
WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, WITH RESPECT TO
ANY GOODS, PARTS AND SERVICES PROVIDED IN CONNECTION WITH
THIS AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
GSTELETECH SHALL NOT BE LIABLE FOR ANY OTHER
DAMAGE INCLUDING, BUT NOT LIMITED TO, INDIRECT, SPECIAL OR
CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
FURNISHING OF GOODS, PARTS AND SERVICE HEREUNDER, OR THE
PERFORMANCE, USE OF, OR INABILITY TO USE THE GOODS, PARTS AND
SERVICE.
GSTeletech test reports or data indicating mean-time-to-failure, mean-timebetween-failure, or other reliability data are design guides and are not intended to
imply that individual products or samples of products will achieve the same results.
These numbers are to be used as management and engineering tools, and are not
necessarily indicative of expected field operation.
These numbers assume a
mature design, good parts, and no degradation of reliability due to manufacturing
procedures and processes.
Handling the GST Repeater
1. Use ESD precautions when dealing with the modules within the repeater so that units are not
damaged.
2. Opening the unit voids warranty.
3. Disconnecting any component within the repeater when powered can damage or destroy the
equipment and will void the warranty.
- Table of Contents 1. OVERVIEW ................................................................................................................ 8
2. SYSTEM CONFIGURATION ...................................................................................... 9
2.1 COVERCELL 25K REPEATER NETWORK SERVICE CONFIGURATION................9
2.2 SYSTEM DESIGN AND OPERATIONS ................................................................. 10
2.2.1 SYSTEM DESIGN ............................................................................................... 10
3. SPECIFICATIONS.................................................................................................... 16
3.1 System Specifications ......................................................................................................16
3.2 Mechanical Specifications...............................................................................................17
3.3 Functions .............................................................................................................................17
4. INSTALLATION ........................................................................................................ 19
4.1 SYSTEM INSTALLATION ..................................................................................................19
4.2 TROUBLESHOOTING........................................................................................................21
1. OVERVIEW
COVERCELL 25K is a dual band repeater which can receive and transmit cellular and PCS
signals in the shadow area, which BTS signals cannot reach. This system has 79dB and 85dB
gain in the cellular band and PCS band respectively with 17dBm and 19dBm maximum power
each.
On the following condition, the band select function can be performed on each path in each
band.
Cellular: A1+A2 or B1+B2
PCS: 5MHz, 10MHz, 15MHz consecutive block select
Specific setting is possible using GUI
The basic structure of CoverCell 25K illustrates that each module is built-in on each path in a
body. The functions of each module are as follow.
4-Plex Cavity Filter: Duplexing input and output signals in the Cellular and PCS frequency
ranges and band combining.
Cellular Drive Module: including LNA, Local and PAM in the cellular band
PCS Drive Module: including LNA, Local, and PAM in the PCS band
Digital Filter: implementing the bandwidth setting and filtering using a digital technology
each band
PSU (Power Supply Unit): Converting AC 120V to respective voltages for each module
Control Board: Checking and controlling each module
IO Board: playing a role as a terminal between PSU and each module
2. SYSTEM CONFIGURATION
2.1 COVERCELL 25K REPEATER NETWORK SERVICE CONFIGURAT
ION
CoverCell 25K RF Repeater receives cellular 800MHz and PCS 1900MHz BTS signals
through a donor antenna installed outside of a building. The signals are amplified, filtered, and
transmitted through a coverage antenna inside of a building. In the reverse, it receives terminal
signals through a coverage antenna and transmits the signals to cellular and PCS BTSs through
a donor antenna.
CoverCell 25K RF Repeater has following functions;
Type of Modulation : CDMA (Cellular, PCS)
Frequency/ Band Select using cavity filters
Bandwidth Setting using PLL, Digital Filter
Output Control using AGC/ALC
Gain Control using attenuators
Figure 1 illustrates CoverCell 25K network configuration in a site. As seen in the Figure 1, the
donor antenna is installed towards PCS and cellular BTSs and the coverage antenna is located
in a place to cover approximately 25,000 square feet.
[Figure 1] COVERCELL 25K RF Repeater Operating Example
2.2 SYSTEM DESIGN AND OPERATIONS
2.2.1 SYSTEM DESIGN
NO
PART
FUNCTIONS
Donor 4-Plex Cavity Filter
Downlink Input, Uplink Output, path separated
Coverage 4-Plex Cavity Filter
Downlink Output, Uplink Input, path separated
Cellular Drive Module
LNA/ PAM, Service Band Select
RCU (Upper)
Repeater Control and High-level Communication
PCS Drive Module (Middle)
LNA / PAM , Service Band Select
Digital Filter (Lower)
Deciding Bandwidth in the Selected Band
7.5V Power Supply Unit
Drive Module Power Supply
10
6
5V Power Supply Unit
Digital Filter Power Supply
IO Board
Terminal board for controlling a repeater
PCS Wave Detector
PCS Service Band noise detect
Cellular Wave Detector
Cellular Service Band noise detect
10
PCS Coupling
PCS RX Service Signal Extract
11
Cellular Coupling
Cellular RX Service Signal Extract
12
Cellular DL_BPF
Blocking IF external signals
13
Cellular UL_BPF
Blocking IF external signals
14
PCS_DL_BPF
Blocking IF external signals
15
PCS_UL_BPF
Blocking IF external signals
[Figure 2] COVERCELL 25K RF Repeater Internal Structure
[Figure 3] COVERCELL 25K RF Repeater Port
NO
PORT
FUNCTIONS
Debug Port
GUI Connecting port, 9pin D-sub
AC Power port
AC 120V 60Hz
LAN1
High-level Communication port
LAN2
High-level Communication port
Coverage ANT
Antenna for terminals
Donor ANT
Antenna for BTS
11
12
2.2.2 Downlink Block Diagram
CoverCell 25K is a dual band repeater that can handle cellular and PCS signals. Basically RF
modules are separated from each path and band. One module can handle all the functions
except 4 plexer and digital filter. Also one integrated chip which includes local and mixer
consists a block and input detect process is performed to prevent external signals from affecting
other signals after signals are through a digital filter.
COVERCELL 25K RF Repeater
Downlink Block Diagram
PAM
Donor
Coverage
LNA
Cellular
Output Det
Mixer + Local
Cavity
Input Det
Cavity
Filter
Filter
Digital Filter
PAM
LNA
PCS
Output Det
Mixer + Local
Input Det
Digital Filter
[Figure 4] COVERCELL 25K RF Repeater Downlink Block Diagram
13
2.2.3 Uplink Block Diagram
The uplink path of CoverCell 25K does not use the input detect function. The gain of a donor
antenna is high enough. Then, the last output power level is not necessarily high. Consequently,
PAM is not necessary. The ALC function is monitoring the last output power and maintaining the
output power to increase stability of the system.
COVERCELL 25K RF Repeater
Uplink Block Diagram
Coverage ANT
Donor ANT
LNA
Cellular
Output Det
Mixer + Local
Cavity
Cavity
Filter
Filter
Digital Filter
LNA
PCS
Output Det
Mixer + Local
Digital Filter
[Figure 5] COVERCELL 25K RF Repeater Uplink Block Diagram
14
2.2.5 Frequency Selection
A1
A2
A3
B1
1930MHz
A1
B2
B3
C3
C4
1990MHz
< Downlink >
A2
A3
B1
B2
B3
< Uplink >
1850MHz
C5
C3
C4
C5
1910MHz
[Figure 7] PCS Band Structure
Based on the band select function, 5MHz, 10MHz, and 15MHz bands can be selected on the fo
llowing condition.
Any 5MHz bands can be chosen in the all the blocks.
10MHz or 15MHz band can be selected in any combinations In the consecutive bands
C1, C2 select is not supported.
15
3. SPECIFICATIONS
3.1 System Specifications
Downlink
Uplink
A1
869 ~ 880
824 ~ 835
A2
890 ~ 891.5
845 ~ 846.5
B1
880 ~ 890
835 ~ 845
B2
891.5 ~ 894
846.5 ~ 849
1930 ~ 1990
1850 ~ 1910
Item
Cellular
Frequency
(MHz)
PCS Frequency (MHz)
Sub Band Filtering
Gain
5, 10, 15MHz BW (tunable)
Cellular
79dB
84dB
PCS
85dB
74dB
5dB peak to peak
Channel power
Cellular
-49dBm ~ -81dBm
Max -73dBm
PCS
-48dBm ~ -85dBm
Max -67dBm
Output
Cellular
17dBm
Power
PCS
19dBm
17dBm
17dBm
AGC
Cellular
23dB
Range
PCS
28dB
≥ 45dBc@±2MHz
Cellular
Roll off
PCS
Group Delay
≥ 30dBc @±0.375MHz
≥ 30dBc @±1.5MHz
≤ 5us
Single &
Cellular
≤ -30dBm @±0.88MHz
2-tone
PCS
≤ -40dBm @±1.2MHz
Noise Figure
≤ 10dB @Max, Mean, Min Gain
Input Inter-modulation
≤ 10dB
≥ 45dBc @ 750kHz
Adjacent
Cellular
Channel
Power
≥ 45dBc @ 1.98MHz
≥ 45dBc @ 885kHz
PCS
Radiated Spurious
Emissions
Refer to Figure 7
A1+A2 or B1+B2
Flatness
Input Range
Remark
≥ 45dBc @ 1.98MHz
≤ -13dBm
Frequency Error
± 300Hz @cellular, ± 150Hz @PCS
Signal Quality
Rho >0.98
16
3.2 Mechanical Specifications
Item
Specification
Remark
RF Connector
N-Type Female
Donor & Coverage ANT Port
AC Power Connector
MS3102A-10SL (3Pin)
AC Supply
AC 120V 60Hz
Out Dimension
17 x 12 x 4.6
Inch
Net Weight
16.5
Kg
Operation Temperature
-10℃ ~ +50℃
Convection cooling
Humidity
5% ~ 85%
Non-condensing
3.3 Functions
Item
Gain Control
Description
• Gain can be controlled between 40dB and 65dB
• Setting gain and current gain can be displayed.
• Regardless of input changes output would be maintained constantly by
AGC
(Auto Gain Control)
controlling its gain.
• AGC Value Setting Through GUI
• ON/OFF Setting Through GUI
• User configurable output limit function
• ALC Level setting through GUI
ALC
(Auto Limit Control)
• Output is greater than a setting value, and then automatically the gain is
reduced.
• Output is reduced, and then automatically the gain is recovered.
• The repeater output is greater than a setting value with a minimum gain.
Then the repeater would shut down.
• User can select A-Band or B-Band in the cellular band.
Band Select
• User can select consecutive 5, 10, 15MHz block in the all the 60MHz block
of the PCS band.
Output Detect
Function
• The output of each path is displayed on GUI
• In order for a repeater not to emit spurious waves more than –13dBm out of band,
monitoring the noise power.
• If spurious waves are greater than -13dBm, controlling its gain
Spurious Check
• If spurious waves are greater than -13dBm with Minimum Gain, Repeater shuts
down
• Recovery Algorithm is working after shutdown
17
• When Initial Setup or Reset, Checking Isolation
• While Operation, Monitoring Oscillation through Highest and Lowest values
comparison of Noise Floor
Oscillation Check
• When Oscillation happens, automatically try stabilizing Isolation through
Repeater Gain Control
• If Oscillation still occurs with Minimum Gain, Repeater Shuts down
• Recovery Algorithm is working after shutdown
DL Input Detect
Function
Auto Recovery
• Monitoring downlink donor antenna input power
• Alarming if input range is abnormal or no signal is inputted.
• When Repeater Shuts down, regularly recovering its output power and
checking its alarming situations
• Monitoring current temperature
Temperature
Monitoring Function
• User Configurable up limits and down limits
When the current temperature is out of range, Repeater shuts down
• When Temperature falls in the normal range, automatically it recovers its
functions.
VSWR Monitoring
Power Supply
Monitoring
Voltage Out of
Range Monitoring
LED Display
• When the VSWR of Forward output is abnormal, alarming and shutdown.
• Recovery Algorithm is working after shutdown
• PSU current monitoring and the total current is over the standard, Alarming
• PSU Low and High Power Alarm Function
• Repeater status is displayed through front LED
18
4. INSTALLATION
4.1 SYSTEM INSTALLATION
4.1.1 Contents of Box (1 SET)
Category
Contents
Quantity
Repeater
COVERCELL 25K Repeater
1 EA
Power Cable
1 EA
Mounting Bracket
1 EA
Screws
1 SET
MANUAL
1 EA
Accessory
USER MANUAL
4.1.2 Caution
1) System Main Power Check: the main input power of this repeater is AC110V
A : 110V ~ 125VAC
B : 110V ~ 125VAC
C : GND
[Figure 8] MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
2) Input Condition Optimization:
A.
Cellular Forward Input Condition: -81 ~ -49dBm
B.
PCS Forward Input Condition: -85 ~ -48dBm
C. Adjusting system input condition to be optimized after comparing a donor antenna input con
dition to A and B
3) Measuring Isolation between Donor/Coverage Antennas
A.
Cellular: ≥96dBc(Gain +15dB)
B.
PCS: ≥100dBc (Gain+15dB)
C. Checking the above conditions, adjusting system input condition to be optimized.
4) The standard installation of this repeater is vertically wall-typed.
19
434
[Figure 9] Dual-band In-building Repeater
GS Teletech Inc. Tech Support
1-866-9-GST-USA (toll free)
300
[Figure 10] Dual-band In-building Repeater
20
4.1.3 System Initiation
1) Check points after connecting networks
A. External LED
① RUN: When Power On, green light blinks. Otherwise, the lamp is off.
② ALARM: When alarming situations happen, the yellow light is on. Otherwise, it is off.
③ SHUT DOWN: When Shut Down situations occur, the yellow light is on. Otherwise, it is off.
[Figure 11] dual-band In-building Repeater Repeater Front LED
B. Checking through Debug Program
C. Checking output power
Checking output status through output monitoring port and the characteristics of unnecessary wavefor
ms using a spectrum analyzer
D. Checking service quality status in the service area
Checking service signal quality status using terminals in the service area
4.2 TROUBLESHOOTING
When the repeater is abnormal, diagnosing with remote control or site debug functions. If major
alarms go off, turn it off and contact customer service at GS Teletech.
a. Troubleshooting should be performed by trained technicians.
b. No internal or external parts should be disassembled or tampered with for any reason.
c. While troubleshooting, technician should use attenuator to check RF Signal output.
21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:11:18 16:40:35+09:00
Create Date                     : 2008:11:18 16:34:20+09:00
Metadata Date                   : 2008:11:18 16:40:35+09:00
Format                          : application/pdf
Title                           : Microsoft Word - GST_CoverCell25K_Rev2Nov062008_.doc
Creator                         : 
Document ID                     : uuid:9386f7b5-ca67-412a-af83-94ccc32c24a5
Instance ID                     : uuid:24011482-bbd6-45a3-9d05-383586911ae0
Page Count                      : 22
Author                          : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U88-COVERCELL25K

Navigation menu