GS Instech GSTR1930DT-SPR CDMA In-Building RF Repeater User Manual 1

GS Instruments Co., Ltd. CDMA In-Building RF Repeater 1

User Manual

Download: GS Instech GSTR1930DT-SPR CDMA In-Building RF Repeater User Manual                            1
Mirror Download [FCC.gov]GS Instech GSTR1930DT-SPR CDMA In-Building RF Repeater User Manual                            1
Document ID810013
Application IDz7OHjgqIQLpxgZAxH9yU+g==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize175.28kB (2191043 bits)
Date Submitted2007-06-29 00:00:00
Date Available2007-08-13 00:00:00
Creation Date2007-06-20 17:59:05
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-06-22 17:23:21
Document Title붙임서류1
Document CreatorWordìš© Acrobat PDFMaker 7.0.7
Document Author: 이 인영

FCC ID : U88GSTR1930DT-SPR
ATTACHMENT E.
- USER MANUAL -
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
1/33
FCC ID : U88GSTR1930DT-SPR
INFORMATION TO USER :
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
CAUTION
Changes or modifications not expressly approved
by the manufacturer responsible for compliance
could void the user's authority to operate the equipment
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
2/33
FCC ID : U88GSTR1930DT-SPR
- INDEX 1. SUMMARY .................................................................................................................4
2. SYSTEM CONFIGURATION .....................................................................................6
3. SPECIFICATIONS................................................................................................... 11
3.1 System Specifications (applicable to both Uplink & Downlink)................................................... 11
3.2 Electrical and Environment Specifications .......................................................................................... 11
3.3 Functions.......................................................................................................................................................... 12
4. SET UP .....................................................................................................................15
4.1 System Set up ................................................................................................................................................ 15
4.2 Troubleshooting ............................................................................................................................................ 18
5. WEB USER INTERFACE .........................................................................................25
5.1 IP Address verification and Explorer setting ...................................................................................... 25
5.2 PCS Web UI ..................................................................................................................................................... 27
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
3/33
FCC ID : U88GSTR1930DT-SPR
1. SUMMARY
US PCS 1900 RF repeater is an analog RF repeater, which improves PCS network.
US PCS 1900 RF repeater receives RF signal from BTS and transmits it to the blanked and
shadowed area, thus providing and improving voice and image data services. US PCS 1900 RF
repeater’s goal is to support BTS’s functions proportionately.
US PCS 1900 RF repeater communicates with BTS wirelessly, thus saving additional costs for its
maintenance.
US PCS 1900 RF repeater consists of PA (Downlink, Uplink), IF, LNA (Downlink, Uplink), I/O &
Control divisions, which are supplied with Alarm LED, thus providing quick and easy
maintenance and troubleshooting of the repeater.
This manual describes in general structure of US PCS1900 repeater, its application, maintenance
and troubleshooting, installation and operation etc.
Abbreviation
PAM: POWER AMPLIFIER MODULE
LNA: LOW NOISE AMPLIFIER
AGC: AUTO GAIN CONTROL
ALC: AUTO LIMIT CONTROL
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
4/33
FCC ID : U88GSTR1930DT-SPR
Ethernet Instruction “ This equipment is indoor use and all the communication wirings
are limited to inside of the building” or similar texts.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the
equipment and shall be easily accessible.
Replaceable batteries instruction
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
5/33
FCC ID : U88GSTR1930DT-SPR
2. System Configuration
2.1 US PCS 1900 service organization
US PCS 1900 repeater decreases blanked and shadowed areas and extends cell coverage by retransmitting signal. The signal is received from BTS via Antenna directly, thus excluding
additional expenses for signal transmission (like cabling). Service organization of CDMA Inbuilding RF repeater is shown at the picture below. Donor Antenna is directed to BTS, and being
divided at Service Antennas are installed in the building and parking place. Pass Loss should be
taken into consideration while dividing and cabling.
 US PCS 1900 Service organization
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
6/33
FCC ID : U88GSTR1930DT-SPR
2.2 System Design and Operation
2.2.1 System design
9 7
10
11
12
13
1 Donor Cavity
2 Service Cavity
3 I/O & NMS Board 4 IF-10MHz
5 IF-15MHz
6 IF-20MHz
7 RVS LNA
Waveform Detector 10 FWD HPA
11
RVS HPA
8 FWD LNA
12
Power Supply
13 HUB
 Repeater’s inside structure
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
7/33
FCC ID : U88GSTR1930DT-SPR
1 Donor Antenna
2 Service Antenna
5 CLI
6 Ethernet HUB
3 AC Input Port
4 DC Input Port
 Repeater’s Top and Bottom panels
 AC & DC ports
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
8/33
FCC ID : U88GSTR1930DT-SPR
2.2.2 Uplink Path
FWD and RVS Gain Budgets have similar structure. In case of Uplink Path, RF signal is
transmitted from Service Antenna to Service Cavity Filter and RVS LNA division, then the signal
is transferred to IF division, where desirable Band is selected by passing 6 Paths of RF Switch
and SAW filter. Selected Band is got together in FWD LNA division, and then transmitted to
Donor Antenna passing through Digital ATT (10dB ATT Range) and Donor Cavity Filter. Then the
signal is transmitted to BTS through Donor Antenna.
 Uplink Block Diagram
2.2.3 Downlink Path
Downlink Path is organized in reverse order of Uplink Path.
In case of Downlink Path, RF signal is transmitted from Donor Antenna to Donor Cavity Filter
and FWD LNA division, then the signal is transferred to IF division, where desirable Band is
selected by passing 6 Paths of RF Switch and SAW filter. Attenuation range is 40dB in Digital
Attenuator. Selected Band is transmitted to FWD Drive Am and Service Cavity Filter, after that
the signal is transferred to Service Antenna.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
9/33
FCC ID : U88GSTR1930DT-SPR
 Downlink Block Diagram
2.2.4 US PCS Frequency Selection
1930
1945
1950
1965
1970
1975
1990
1995
f (MHz)
1915
f (MHz)
< Forward Band Structure >
1850
1865
1870
1885
1890
1895
1910
< Reverse Band Structure >
 PCS Band Structure
US PCS 1900 repeater has 5MHz, 10MHz, 15MHz, 20MHz Paths in IF division, so any of these
bandwidths can be chosen for providing service. But there are some cases when this choice is
not applicable.
Not continuous 4 Paths [5 MHz each], so total band is 20MHz (i.e. A1A3B2C1,
A1A2B1B2)
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
10
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
10/33
FCC ID : U88GSTR1930DT-SPR
3. SPECIFICATIONS
3.1 System Specifications (applicable to both Uplink & Downlink)
Characteristics
Frequency Range
Specification
Forward
1930 ~ 1995MHz
Reverse
1850 ~ 1915MHz
System Group Delay
< 5㎲
Characteristic Impedance
50 ohm
VSWR
Max1.5 : 1
Input Power Range
-100 ~ -20dBm (for both Uplink and Downlink)
System Isolation
> 90dB
Gain Range
50dB ~ 90 dB
Noise Figure
< 4.5 dB @ Max Gain
<12 dB @Min Gain
Gain Adjustment Step(Accuracy)
1dB(±0.5dB)
Pass Band Ripple
2.5dB(±1.25dB)
Maximum Output Power
1W / 30dBm
>45 dBc @885kHz
Spurious Emissions
>55 dBc @1.98kHz
<-13dBm @Fc±2.25MHz (RBW: 1MHz)
IF Path
5MHz/10MHz/15MHz/20MHz
IF Frequency
FWD: 200 MHz, RVS: 120MHz
Band Select
Local Shift & RF Switching
Roll Offs
> 50dBc @1MHz
Waveform Quality Factor
min 0.912
3.2 Electrical and Environment Specifications
Characteristics
Specification
Size(inch) / Type
16.1(W) x 20.5(L) x 6.1(H)
Power
AC 120V 60Hz 5.5A
Temperature / Weight
Connector TYPE
-10℃ ~+50℃/44.5lbs
N Type Female
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
11
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
11/33
FCC ID : U88GSTR1930DT-SPR
3.3 Functions
Parameter
Gain Control
Specification
• Adjustable DL and UL Gain range 50~90dB
• Display default Gain and current Gain function
• AGS (Auto Gain Setting) Use convenient Set-up
AGS start
AGS (Auto Gain Setting)
D/L,U/L ATT: 0dB
HPA: ON, ALC: ON, Isolation Check: ON
→ Installation time calculation: in AGS .
Isolation generation: Wave detection using
noise floor level detect
Isolation analysis: isolation fault Æ System
Gain 1dB reduce
AGS
Auto Gain
Setting
No
System Gain + 7dB<
isolation detection value
Sever ANT Tuning
Re-installation: AGS
Yes
No
No
Max. Gain & isolation O.K
Yes
Gain reduce &
isolation O.K
Display Notice
HPA: Off
HPA: ON, Gain balance: ON,
AGC: ON, Shut-down: ON
Current setting
maintenance
Yes
HPA: ON
AGS done
AGC
Auto Gain
Control
• It always operates in Downlink AGC ON status
• To maintain same Downlink output power despite flexible input signal strength.
• To add or subtract Attenuation level referring to AGC Power Limit level.
• To limit output power as far as default range
ALC
Auto Limit
Control
• Set up via GUI
• Automatic Gain decrement when output power of repeater is higher than default level
• Automatic Gain recovery when output power of repeater is reduced.
• Shutdown when output power is higher than default level in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
Gain Balance
• Downlink ATT is applied to Uplink during AGC state
• Setting and maintenance of output level
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
12
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
12/33
FCC ID : U88GSTR1930DT-SPR
• Additional attenuation to ALC Level
• Isolation Check in initial set up or Reset
• Monitoring Oscillation comparing to minimum/maximum Noise Floor level
Oscillation Check
• When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function.
• Shutdown repeater when Oscillation still goes in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
• Noise Floor Observation in case of ±2.25MHz down at the center
Spurious
• In case of Noise level > –13dBm, Spurious Emission is stabilized automatically
Emission Alarm
• In case of Oscillation Spurious Emission Alarming in Minimum Gain, repeater will be shutdown
• Automatically Switch to Recovery Algorithm at Shutdown
Band Select
• To select either 5MHz/10MHz/15MHz/20MHz
Power
Monitoring
• Monitoring repeater’s output level
Function
DL Input control
• Monitoring Donor ANT input power of DL
Automatic
• When in repeater shutdown, it periodically recovers output power of repeater then monitors
Recovery
alarming
• Support HTTPS for Web Browser security
Security
• User authentication through User ID and Password
• Monitoring temperature of repeater
Temperature
• Maximum and minimum set up is possible. Shutdown in over temperature
control
• Automatic recovery after temperature becomes normal. (Hysteresis 10 degree)
• Monitoring VSWR of Donor ANT Port (Every one and half minute)
VSWR
• Reporting VSWR Alarm and Shutdown when the rate is 3:1
Monitoring
• Automatic Recovery Algorithm conversion after Shutdown status
IP address
• When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address,
report via E-mail
reports to operator.
DHCP Client
• Automatic IP assignment
DHCP Server
• Server function for automatic IP assignment
Web GUI
SNMP Agent
LED Display
• Remote and local user browser support through Web Browser
• NMS report via SNMPv2 Trap
• LED displays power and operation status on front side of repeater system.
• DL input and output signal level is verified by LED bar.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
13
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
13/33
FCC ID : U88GSTR1930DT-SPR
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
14
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
14/33
FCC ID : U88GSTR1930DT-SPR
4. SET UP
4.1 System Set up
4.1.1 Constitution (based on 1 SET)
Parameter
Item
Quantity
Remark
Major accessory
CDMA 30dBm repeater
1 EA
Manufacture company supply
Ethernet Cable (cross)
1 EA
Power Supply Cable
1 EA
Fixable Screw x 4 (Size: φ1/2”,
1 SET
Additional
components
length: 2” )
Manufacture company supply
Ground Cable
1 EA
CD which contains User Manual
1 EA
and installation Guide
User Manual
Installation Guide (Book)
1 EA
Manufacture company supply
Donor ANT
1EA
Establishment construction company
Server ANT
1EA
preparation
Antenna connection Cable
TBD
Spectrum Analyzer
1EA
Antenna
RF Cable
Repeater quality
confirmation
equipment
Establishment construction company
preparation
Establishment construction company
preparation
4.1.2 Notice
1 ) System Power check : Major electricity is A C 1 1 0 V, therefore please input electricity after power
verification.
2) Input condition optimization: DL input condition is -56 ~ -16dBm. User should verify input condition of
Donor ANT.
3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 95dBc (Gain+
15dB). User should check its condition before installation.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
15
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
15/33
FCC ID : U88GSTR1930DT-SPR
 MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
4.1.3 System set up
1) This equipment is basically wall mountable installation.
2) Once aforementioned process is done, open for service get ready.
3) For grounding, there is a grounding terminal in main power supply side and the grounding
terminal on a site and unit should be connected same.
4) System installation work is basically performed more than two people and should be careful for
unexpected accident.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
16
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
16/33
FCC ID : U88GSTR1930DT-SPR
4.1.4 Open for service
 Case mounts
1) Check points before open
a. Verification of system installation status
Electricity, In/out antenna, coaxial cable connection, equipment mounts status.
b. Verification of system accessories
User should check whole necessary accessories.
c. Check receipt signal level
User should check whether receipt environmental condition is in accordance with system specification,
so that system operation will be optimized.
2) Check points after open
a. Check by external LED
① RUN: Green light ON (Off: Green light off)
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
17
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
17/33
FCC ID : U88GSTR1930DT-SPR
② ALARM: Green light in normal status, Red light in alarming
③ SHUT DOWN: Green light in normal status, Red light in Shutdown
⑤ Number of LED bar on front side of repeater will show input signal level.
Less than -56dBm: LED 1bar
-56dBm~-48dBm: LED 2bars
-48dBm~-39dBm: LED 3 bars
-39dBm~-31dBm: LED 4 bars
-31dBm~-23dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level
Less than +24dBm: LED 1bar
+25dBm~+26dBm: LED 2 bars
+27dBm: LED 3 bars
+28dBm: LED 4 bars
More than +29dBm: LED 5 bars
 Front LED Indicator
4.2 Troubleshooting
In case, abnormal operation is detected, user should check abnormal parts via remote accessible
function or field debug, then conduct repair after turn it off.
4.2.1 Necessary Testing and Measuring equipment
a. RF Power Meter: 10Watt Max, 50ohm
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
18
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
18/33
FCC ID : U88GSTR1930DT-SPR
b. Signal Generator: 3GHz
c. Spectrum Analyzer: 3GHz
d. Multi Meter
4.2.2 Notice
a. Trouble shooting should be performed with drastic knowledge basis.
b. Unsure parts should not be disassembled.
c. When in trouble shooting, technician should use attenuator to check output side.
4.2.3 Note at set up process / Check point after open for service
Item
Check Point
Trouble shooting
Input Level
Note
before
* System Input power range
system
Down Link
-100dBm/Total ~ -20dBm/Total
Up Link
-100dBm/Total ~ -20dBm/Total
operation
Gain
Same as
above
* System Gain
Down Link
50 ~ 90dB
Up Link
50 ~ 90dB
Output power
Same as
above
* Output power at edge port side
Down Link
30dBm/Total
Up Link
30dBm/Total
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
19
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
19/33
FCC ID : U88GSTR1930DT-SPR
* Please check quantity of all accessories with specification
Check in
* Check points before open for
Advance
service
before you set up.
* Fit cable length in accordance with field condition.
* Set up Donor antenna to assure enough Isolation (More
than 97dBc)
* Check following status
- Fixable level of antenna support pole
- Connection status between antenna and RF cable
- RF Cable construction and fixed status
- fix of repeater and installation status
- Electricity construction and proper AC power status
- Plug status and electricity voltage status
Check
after
* Check points after open for service
open
- wall socket and voltage status
- Grounding (EARTH) status
- Direction of Donor antenna
(PN Offset and neighborhood BTS to be considered.)
- Ground status of repeater (unit itself)
- Coaxial cable construction status
- Connector combiner connection status
- Cable connection status against leakage of water
4.2.4 Trouble shooting guide related to RF
Symptom
When repeater
does not work
properly
Same as above
Check Point
* Checking Electricity Cord
Troubleshooting
* Re-plug in AC power cord
connection status
* Checking electricity input to
AC power outlet.
* Please verify AC power input by using DVM (Digital Voltage
Meter)
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
20
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
20/33
FCC ID : U88GSTR1930DT-SPR
* Please Check following status
- Proper maximum output power limit level
- BTS input level (Spectrum Level)
When in
alarming
* DL over-input alarm
- Input RSSI value at Status mode
- Downlink Attenuation level
- Downlink Attenuation Table
* Please reset AC power upon complete Alarm trouble shooting
When in
alarming
When in
alarming
* Please make sure output power is operated normally.
* DL over-output alarm
* Please reset AC power upon complete Alarm trouble
shooting.
* UL over-output alarm
* Please make sure output level is operated normally
* Please reset AC power upon complete Alarm trouble shooting
* Please Check following status
- Antenna port connection
When in
alarming
* VSWR alarm
- Whether inner-output cable is damaged or not.
* Please reset AC power upon complete Alarm trouble
shooting
When in
alarming
When in
alarming
* IF Module alarm
* DL, UL PAM alarm
When in
alarming
* Please verify IF Module LED is On.
* When LED is Off, module should be defective.
* Please reset AC power upon complete Alarm trouble shooting
* Please verify DC power by using DVM (Digital Voltage Meter)
* DC matter/Current alarm
* Please reset AC power upon complete Alarm trouble
shooting.
When in
alarming
* Please check Isolation between Donor and Server.
* UL Oscillation
* Please reset AC power upon complete Alarm trouble
shooting.
When in
alarming
* DL / UL LNA alarm
* Please check connection status of LNA.
* Please reset AC power upon complete Alarm trouble shooting
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
21
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
21/33
FCC ID : U88GSTR1930DT-SPR
When in
* Please Check following status
alarming
- Setting level of maximum temperature limit
* Temperature alarm
- Temperature offset is normal or not.
- Circumstance temperature.
* Please reset AC power upon complete Alarm trouble shooting
When in
* DL low-input alarm
alarming
When in
* Please reset AC power upon complete Alarm trouble shooting
* Please Check following status
alarming
- Output power level is normal or not.
* DL low-output alarm
- Whether minimum output limit level is normal.
* Please reset AC power upon complete Alarm trouble shooting
When in
* RF OFF
alarming
When output
power is no
longer strong
or problem
Same as above
* Technician should verify
category of alarm at the front
* Please reset AC power upon complete Alarm trouble shooting
* When Red light on the Shutdown LED, technician should
troubleshoot the alarm via Notebook computer.
side of repeater.
* Technician should connect
* Reconnect the connector.
antenna with output port of
* Please change it if the connector is detective.
repeater.
* Please make sure all
connectors are fastened
Same as above
* Check the input level not to
* Increase output power or check input change of BTS side.
be too low.
Same as above
Same as above
* Check Gain of the unit
* Cable loose or over loss.
* If the Gain is different from normal level, please contact A/S
team.
* Please contact installer or service provider upon verification.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
22
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
22/33
FCC ID : U88GSTR1930DT-SPR
In case of drop
call or bad
* Check receipt signal strength
in the service area not to be
signal after
* Increase output power level of repeater by adjusting
attenuation level.
too low.
set up
* If receipt signal strength is
not a problem, please check
Same as above
* Please increase output level of Uplink signal, then setting by
optimal level..
delay of calling time.
* Please contact network management team or service
Same as above
* Check receipt signal strength
In case, output
* Check connection fastened
* If connection is not proper, please make sure connector and
Signal
between antenna and cable
cable to be re-connected then check the output power again.
wavelength is
(Signal wavelength should be
not shown flat
flat and stable if technicians
or looks like
shake CABLE. If not, it is
oscillation
connection problem.)
Same as above
Same as above
provider
* Input level change or
* Check input level from BTS side.
module blazing
* Check performance of each module.
(Diagnosed by A/S team.)
* Please check VSWR of the
* Change to normal Cable.
Cable is normal.
4.2.4 Trouble shooting guide related to NMS
Symptom
Link fail
Check Points
* Communication problem
Same as above
Same as above
* CLI Connection, Cable
Troubleshooting
* In case of Ethernet, check set up level of IP, Gateway and so
on, when you use Ethernet.
* Make sure 1:1 connection.
status check
* CLI connection Check by
* Please verify Port number of PC communication.
USB to Serial Cable
* Please check Cable connection status.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
23
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
23/33
FCC ID : U88GSTR1930DT-SPR
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
24
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
24/33
FCC ID : U88GSTR1930DT-SPR
5. WEB USER INTERFACE
5.1 IP Address verification and Explorer setting
5.1.1 IP Address verification and Explorer setting
(1) Start->Control Panel->Network Connections
(2) Double-click Local Area Connections at LAN or High Speed internet
(3) Click Internet Protocol (TCP/IP) at General tap and click Properties.
(4) Apply automatic IP address assignment at local connection
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
25
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
25/33
FCC ID : U88GSTR1930DT-SPR
(5) Verify assigned IP address at local connection.
(Unless IP address is not assigned, please click repair.)
5.1.2 Explorer option setting
- Proceed step by step as indicated in below. All files and records should be removed.
- Set up mode will be displayed after (2) click.
- Please proceed along following set up mode screen shot.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
26
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
26/33
FCC ID : U88GSTR1930DT-SPR
5.2 PCS Web UI
5.2.1 Web UI connection
- Input desirable IP address.
- Default Use Name and Password for Web UI is ‘admin’.
5.2.2 Link menu
- Following screen shot is located left-top side of main menu and those are linked to relative
window.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
27
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
27/33
FCC ID : U88GSTR1930DT-SPR
5.3 Web UI control
5.3.1 Status
- Currently setting level check at this menu tap.
5.3.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
28
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
28/33
FCC ID : U88GSTR1930DT-SPR
5.3.3 Alarm Configuration
- (1) On/Off function for entire alarm report
- (2) Alarm status
- (3) On/Off function for individual alarm category
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button.
5.3.4 Communication Configuration
- This provides all necessary information related to network
- To provide relative information about DHCP and modem
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
29
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
29/33
FCC ID : U88GSTR1930DT-SPR
5.3.5 User Management
- Add and Remove user, Assigning accessibility
- (1) User Registration: Click Register after input required information
- (2) User Removal: Click Delete upon click of user name you wish to remove.
- (3) Super User: Accessible to all kinds of information path
Read/Write: Accessible to all kinds of information path except for User management path.
Read: Checking status only. No control
5.3.6 Logs
- All users’ access record will be saved as a log.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
30
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
30/33
FCC ID : U88GSTR1930DT-SPR
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
31
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
31/33
FCC ID : U88GSTR1930DT-SPR
5.3.7 Sub System/Mailing List
- Set up e-mail address the place you wish to receive alarm.
5.3.8 Troubleshooting
Following is a trouble shooting table, which is frequently occurred to repeater and treatment
method.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
32
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
32/33
FCC ID : U88GSTR1930DT-SPR
5.3.9 Remote Software Upgrade
Upload repeater operation program.
5.3.10 System Reset
- Reset repeater.
HYUNDAI CALIBRATION & CERTIFICATION
TECHNOLOGIES CO., LTD.
33
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-013
33/33

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Company                         : 한국기술투자(주)
Source Modified                 : D:20070620085808
Creator Tool                    : Word용 Acrobat PDFMaker 7.0.7
Modify Date                     : 2007:06:22 17:23:21+09:00
Create Date                     : 2007:06:20 17:59:05+09:00
Metadata Date                   : 2007:06:22 17:23:21+09:00
Document ID                     : uuid:acc23d0a-7c6b-4c2e-89f0-f5c1b5a1ea27
Instance ID                     : uuid:22068320-4b31-435f-bb57-63ef99bb4d12
Version ID                      : 2
Format                          : application/pdf
Title                           : 붙임서류1
Creator                         : 이 인영
Subject                         : 
Headline                        : 
Page Count                      : 33
Page Layout                     : OneColumn
Author                          : 이 인영
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U88GSTR1930DT-SPR

Navigation menu