SD150

Liquid Cooled Diesel Engine Generator Sets

Standby Power Rating
150KW 60 Hz / 150KVA 50 Hz

Prime Power Rating
120KW 60 Hz / 120KVA 50 Hz

Power Matched

GENERAC 7.1DTA ENGINE
Turbo After Cooled

FEATURES
n

n

n

INNOVATIVE DESIGN & PROTOTYPE TESTING are key
components of GENERAC'S success in "IMPROVING POWER
BY DESIGN." But it doesn't stop there. Total commitment to
component testing, reliability testing, environmental testing,
destruction and life testing, plus testing to applicable CSA, NEMA,
EGSA, and other standards, allows you to choose GENERAC
POWER SYSTEMS with the confidence that these systems will
provide superior performance.
TEST CRITERIA:
✓ PROTOTYPE TESTED
✓ SYSTEM TORSIONAL TESTED
✓ ELECTRO-MAGNETIC INTERFERENCE
✓ NEMA MG1 EVALUATION
✓ MOTOR STARTING ABILITY
✓ SHORT CIRCUIT TESTING
✓ UL COMPLIANCE AVAILABLE
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE
REGULATION. This state-of-the-art power maximizing regulation
system is standard on all Generac models. It provides optimized

FAST RESPONSE to changing load conditions and MAXIMUM MOTOR
STARTING CAPABILITY by electronically torque-matching the surge
loads to the engine.

n
n
n
n

SINGLE SOURCE SERVICE RESPONSE from Generac's dealer
network provides parts and service know-how for the entire unit, from
the engine to the smallest electronic component. You are never on your
own when you own a GENERAC POWER SYSTEM.
ECONOMICAL DIESEL POWER. Low cost operation due to modern
diesel engine technology. Better fuel utilization plus lower cost per gallon
provide real savings.
LONGER ENGINE LIFE. Generac heavy-duty diesels provide long
and reliable operating life.
GENERAC TRANSFER SWITCHES, SWITCHGEAR AND
ACCESSORIES. Long life and reliability is synonymous with GENERAC
POWER SYSTEMS. One reason for this confidence is that the
GENERAC product line includes its own transfer systems, accessories,
switchgear and controls for total system compatibility.

APPLICATION
& ENGINEERING DATA

SD150

GENERATOR SPECIFICATIONS

ENGINE SPECIFICATIONS

TYPE .............................................................. Four-pole, revolving field
ROTOR INSULATION .............................................................. Class H
STATOR INSULATION ............................................................ Class H
TOTAL HARMONIC DISTORTION ............................................... <3%
TELEPHONE INTERFERENCE FACTOR (TIF) ........................... <50
ALTERNATOR ........................................ Self-ventilated and drip-proof
BEARINGS (PRE-LUBED & SEALED) ................................................ 1
COUPLING ............................................................ Direct, Flexible Disc
LOAD CAPACITY (STANDBY) .................................................... 100%
LOAD CAPACITY (PRIME) .......................................................... 110%

MAKE ....................................................................... GENERAC/DEUTZ
MODEL .................................................................. BF6M1013FC Deutz
CYLINDERS .......................................................................................... 6
DISPLACEMENT ................................................... 7.1 Liter (433 cu.in.)
BORE ......................................................................... 108 mm (4.25 in.)
STROKE ..................................................................... 130 mm (5.12 in.)
COMPRESSION RATIO ............................................................. 17.6:1
INTAKE AIR ................................................. Turbocharged/Aftercooled
NUMBER OF MAIN BEARINGS .......................................................... 7
CONNECTING RODS ............................................. Drop Forged Steel
CYLINDER HEAD ................................................................... Cast Iron
PISTONS ........................................................................ Aluminum Alloy
CRANKSHAFT .......................... Die Forged, Induction Hardened Steel

NOTE: Emergency loading in compliance with NFPA 99, NFPA
110, paragraph 5-13.2.6. Generator rating and performance in
accordance with ISO8528-5, BS5514, SAE J1349, ISO3046 and
DIN6271 standards.

EXCITATION SYSTEM
❐ PERMANENT MAGNET EXCITER ............. Eighteen pole exciter
Magnetically coupled DC current
Mounted outboard of main bearing
REGULATION .................................................................. Solid-state
+1% regulation

✓
✓
✓
✓
✓

GENERATOR FEATURES
■ Four pole, revolving field generator, directly connected to the
engine shaft through a heavy-duty, flexible disc for permanent
alignment.
■ Generator meets the temperature rise standards for class "F"
insulation as defined by NEMA MG1-32.6, while the insulation
system meets the requirements for the higher class "H" rating.
■ All prototype models have passed a three-phase symmetrical
short circuit test to assure system protection and reliability.
■ All prototype models are tested for motor starting ability by
measuring the instantaneous voltage dip with a waveform data
acquisition system.
■ All models utilize an advanced wire harness design for reliable
interconnection within the circuitry.
■ Magnetic circuit, including amortisseur windings, tooth and skewed
stator design, provides a minimal level of waveform distortion and
an electromagnetic interference level which meets accepted
requirements for standard AM radio, TV, and marine radio
telephone applications.
■ Voltage waveform deviation, total harmonic content of the AC
waveform, and T.I.F. (Telephone Influence Factor) have been
evaluated to acceptable standards in accordance with NEMA
MG1-32.
■ Alternator is self-ventilated and drip-proof constructed.
■ Fully life-tested protective systems, including "field circuit and
thermal overload protection" and optional main-line circuit breakers
capable of handling full output capacity.
■ System Torsional acceptability confirmed during Prototype Testing.

VALVE TRAIN
LIFTER TYPE .................................................................................. Solid
INTAKE VALVE MATERIAL .................................. Heat Resistant Steel
EXHAUST VALVE MATERIAL .............................. Heat Resistant Steel
HARDENED VALVE SEATS .............................................. Replaceable
ENGINE GOVERNOR
❐ ELECTRONIC ...................................................................... Standard
FREQUENCY REGULATION, NO-LOAD TO FULL LOAD ... 0.5%
STEADY STATE REGULATION ............................................. 0.25%
LUBRICATION SYSTEM
TYPE OF OIL PUMP ..................................................................... Gear
OIL FILTER .............................................................. Full flow, Cartridge
CRANKCASE CAPACITY ...................................... 21 Liters (22.2 qts.)
COOLING SYSTEM
TYPE OF SYSTEM ............................. Pressurized, Closed Recovery
WATER PUMP ................................................. Pre-Lubed, Self-Sealing
TYPE OF FAN ............................................................................ Pusher
NUMBER OF FAN BLADES ................................................................. 6
DIAMETER OF FAN ..................................................... 660 mm (26 in.)
COOLANT HEATER ....................................................... 120V, 1800 W
FUEL SYSTEM
FUEL .......................................................... #2D Fuel (Min Cetane #40)
(Fuel should conform to ASTM Spec.)
FUEL FILTER ........................................................................... 5 Micron
FUEL INJECTION PUMP ........................ Bosch, Unit type cam driven
FUEL PUMP ......................................................................... Mechanical
INJECTORS .................................................... Multi-Hole, Nozzle Type
ENGINE TYPE ............................................................... Direct Injection
FUEL LINE (Supply) ................................................. 6.35 mm (0.25 in.)
FUEL RETURN LINE ................................................ 6.35 mm (0.25 in.)
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR ......................... 20 Amps at 12 V
STARTER MOTOR ........................................................................ 12 V
RECOMMENDED BATTERY ............................... 12 Volt, 90 A.H., 27F
GROUND POLARITY .............................................................. Negative

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046
and DIN6271). Prime (Unlimited Running Time): Applicable for supplying electric power in lieu of commercially purchased power. Prime power is the maximum power available at variable load. A 10% overload
capacity is available for 1 hour in 12 hours. (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

SD150

OPERATING DATA
GENERATOR OUTPUT
120/240V, 1-phase, 1.0
120/208V, 3-phase, 0.8
120/240V, 3-phase, 0.8
277/480V, 3-phase, 0.8
600V, 3-phase, 0.8 pf

VOLTAGE/KW-60Hz
pf
NOTE: Consult your
pf
Generac dealer for
pf
additional voltages.
pf

GENERATOR OUTPUT VOLTAGE/KVA-50Hz
110/220V, 1-phase, 1.0 pf
115/200V, 3-phase, 0.8 pf
NOTE: Consult your
Generac dealer for
100/200V, 3-phase, 0.8 pf
additional voltage
231/400V, 3-phase, 0.8 pf
480V, 3-phase, 0.8 pf
MOTOR STARTING KVA
Maximum at 35% instantaneous voltage dip
with standard alternator; 50/60 Hz
with optional alternator; 50/60 Hz
FUEL
Fuel consumption—60 Hz

Fuel consumption—50 Hz

Load
liters/hr.
gal./hr.
liters/hr.
gal./hr.

COOLING
Coolant capacity

STANDBY

PRIME

SD150

SD150

150
150
150
150
150

Rated AMP
625
520
451
226
180

120
120
120
120
120

Rated AMP
500
416
361
180
144

120
150
150
150
150

Rated AMP
545
433
433
217
180

96
120
120
120
120

Rated AMP
436
346
346
173
144

231/240V
390
325

400/480V
405
338

231/240V
390
325

400/480V
405
338

25%
9.3
2.5
7.4
2.0

50%
17.3
4.6
13.8
3.6

75%
25.1
6.6
20.1
5.3

100%
32.6
8.6
26.0
6.9

25%
7.4
2.0
5.9
1.6

50%
13.8
3.6
11.0
2.9

75%
20.1
5.3
16.0
4.2

System - lit. (gal)
Engine - lit. (gal)
Radiator - lit. (gal)
Coolant flow/min.
60 Hz - lit. (gal)
50 Hz - lit. (gal)
Heat rejection to coolant @ full load
BTU/hr.
Air to radiator in
60 Hz - m3/min. (cfm)
enclosed unit
50 Hz - m3/min. (cfm)
Max. external pressure drop on radiator in. H2O
Max. air temperature to radiator
°C (°F)
Max. ambient temperature
°C (°F)

19.0 (5.0)
9.8 (2.6)
9.2 (2.4)
159.0 (42.0)
132.5 (35.0)
344,700
159 (5,600)
132 (4,667)
0.5
48.9 (120)
43.3 (110)

19.0 (5.0)
9.8 (2.6)
9.2 (2.4)
159.0 (42.0)
132.5 (35.0)
275,760
159 (5,600)
132 (4,667)
0.5
48.9 (120)
43.3 (110)

COMBUSTION AIR REQUIREMENTS
Flow at rated power
60 Hz - m3/min. (cfm)
50 Hz - m3/min. (cfm)

14.2 (501.0)
11.3 (398.9)

11.3 (400.8)
9.0 (319.2)

EXHAUST
Exhaust flow at rated output 60 Hz - m3/min. (cfm)
50 Hz - m3/min. (cfm)
Max recommended back pressure in. Hg (kPa)
Exhaust temperature at rated output °C (°F)
Exhaust outlet size
mm. (in.)

38.6 (1362)
30.7 (1085)
5.1 (1.5)
538 (1000)
127 (5.0)

30.9 (1090)
24.6 (868)
5.1 (1.5)
538 (1000)
127 (5.0)

1800 / 1500
221 / 176
7.8 (1535)
6.5 (1280)
223 / 213

1800 / 1500
178 / 141
7.8 (1535)
6.5 (1280)
180 / 171

40
104

40
104

1066
3500

1066
3500

ENGINE
Rated RPM
HP at rated KW
Piston speed
BMEP

60 Hz / 50 Hz
60 Hz / 50 Hz
60 Hz - m./sec. (ft./min.)
50 Hz - m./sec. (ft./min.)
60 Hz / 50 Hz - psi

DERATION FACTORS
Temperature
-3.5% for every 10oC above - °C
-2.77% for every 10oF above - °F
Altitude
-1.1% for every 100 m above - m
-3.5% for every 1000 ft. above - ft.

100%
26.0
6.9
20.8
5.5

STANDARD ENGINE & SAFETY FEATURES
■
■
■
■
■
■
■
■
■
■
■
■

High Coolant Temperature Automatic Shutdown
Low Coolant Level Automatic Shutdown
Low Oil Pressure Automatic Shutdown
Overspeed Automatic Shutdown (Solid-state)
Crank Limiter (Solid-state)
Oil Drain Extension
Radiator Drain Extension
Factory-Installed Cool Flow Radiator
Closed Coolant Recovery System
UV/Ozone Resistant Hoses
Rubber-Booted Engine Electrical Connections
Coolant Heater

■
■
■
■
■
■
■
■
■
■
■
■

SD150

Secondary Fuel Filter
Fuel Lockoff Solenoid
Stainless Steel Flexible Exhaust Connection
Battery Charge Alternator
Battery Cables
Battery Tray
Vibration Isolation of Unit to Mounting Base
12 Volt, Solenoid-activated Starter Motor
Air Cleaner
Fan Guard
Control Console
Radiator Duct Adaptor

OPTIONS
n
n

n
n
n

n

OPTIONAL COOLING SYSTEM ACCESSORIES
❍ 208/240V Coolant Heater

n

OPTIONAL FUEL ACCESSORIES
❍ Flexible Fuel Lines
❍ UL Listed Fuel Tanks
❍ Base Tank Low Fuel Alarm
❍ Primary Fuel Filters
OPTIONAL EXHAUST ACCESSORIES
❍ Critical Exhaust Silencer
OPTIONAL ELECTRICAL ACCESSORIES
❍ 2A Battery Charger
❍ 10A Dual Rate Battery Charger
❍ Battery, 12 Volt, 135 A.H.
OPTIONAL ALTERNATOR ACCESSORIES
❍ Alternator Upsizing
❍ Alternator Strip Heater
❍ Alternator Tropicalization
❍ Voltage Changeover Switch
❍ Main Line Circuit Breaker

n

ADDITIONAL OPTIONAL EQUIPMENT
❍ Automatic Transfer Switch
❍ Isochronous Governor
❍ 3 Light Remote Annunciator
❍ 5 Light Remote Annunciator
❍ 20 Light Remote Annunciator
❍ Remote Relay Panels
❍ Unit Vibration Isolators
❍ Oil Make-Up System
❍ Oil Heater
❍ 5 Year Warranties
❍ Export Boxing
❍ GenLink® Communications Software
OPTIONAL ENCLOSURE
❍ Weather Protective
❍ Sound Attenuated
❍ Aluminum and Stainless Steel
❍ Enclosed Muffler

Distributed by:

CONTROL CONSOLE OPTIONS
❍ Analog Control "C" Panel (Bulletin 0151160SBY)
❍ Analog/Digital Control "E" Panel (Bulletin 0161310SBY)

Design and specifications subject to change without notice.

Dimensions shown are approximate.

Contact your Generac dealer for certified drawings.

DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.

WEIGHT: 3300 lbs. - OPEN
4300 lbs. W/ ENCLOSURE

mm [in]

®

GENERAC POWER SYSTEMS, INC. • P.O. BOX 8 • WAUKESHA, WI 53187
262/544-4811 • FAX 262/544-4851
Bulletin 0167290SBY / Printed in USA 01.03

All specifications subject to change without notice.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2003:01:27 09:24:24
Producer                        : Acrobat Distiller 4.0 for Windows
Subject                         : SD100
Author                          : dwhite
Creator                         : Adobe PageMaker 6.5
Title                           : SD100
Modify Date                     : 2003:01:27 09:24:37-06:00
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu