Gentron GG6000P User Manual GENERATOR Manuals And Guides 1107415L
User Manual: Gentron GG6000P GG6000P GENTRON GENERATOR - Manuals and Guides View the owners manual for your GENTRON GENERATOR #GG6000P. Home:Tool Parts:Gentron Parts:Gentron GENERATOR Manual
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
I EN I RON Owner's 6OOOW ® Manual PROPANI- (_ENERATOR P|easeread Slidsavethese|listruet|elis, HAVEOUESTIOHS ORHEEDSERVICE DO HOTRETURNTOSTORE! PL_SE CALLTOLLFREE," 888.896.6881 www. GentronUSA. com G Carbon Using a generator Monoxide indoors WILL KiLL YOU iN MINUTES. Carbon Monoxide Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even If you cannot smell the exhaust, you could be breathing CO. • NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air. • ONLY use a generator outdoors and far away from open windows, vents. These openings can pull in generator exhaust. doors, and Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning. 6000W Pro ane Generator Table of Contents Topic Page Limited Warrant 3 Safety Guidelines 5 General Precautions 6 Assembly 15 Battery 17 Propane Connection 18 Operation/Starting 19 Inspection, Generator Cleaning and Maintenance 25 Installation 26 Compliance 28 Specifications 29 Part Lists 30 WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/OR VOIDING OF YOUR WARRANTY. GENTRON® WILL NOT BE LIABLE FOR ANY DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS. 2 Owner's anual Limited Warranty GENTRON® warrants to the original purchaser who uses the product in a consumer application (personal, residential or household usage) that all products covered under this warranty are free from defects in material and workmanship for one year from the date of purchase. All products covered by this limited warranty which are used in commercial applications (i.e. income producing) are warranted to be free of defects in material and workmanship for 90 days from the date of original purchase. Products covered under this warranty include air compressors, air tools, service parts, pressure washers and generators. GENTRON® components to the normal replacement final. will repair or replace, at GENTRON® sole option, products or which have failed within the warranty period. Service will be scheduled according work flow and business hours at the service center location, and the availability of parts. All decisions of GENTRON® with regard to this limited warranty shall be This warranty gives you specific state to state. RESPONSIBILITY legal rights, and you may also have other rights which vary from OF ORIGINAL PURCHASER (initial User): To process a warranty claim on this product, DO NOT return item to the retailer. The product must be evaluated by an Authorized Warranty Service Center. For the location of the nearest Authorized Warranty Service Center call toll free 888.896.6881. Retain original cash register Use reasonable Manual(s). sales receipt care in the operation Deliver or ship the product be paid by the purchaser. as proof and maintenance to the Authorized Warranty of purchase for warranty of the product as described in the Owner's Service Center. Freight costs, if any must If the purchaser does not receive satisfactory results form the Authorized Center, the purchaser should contact GENTRON@. 3 to work. Warranty Service 6000W Propane Gener; Limited Warranty THIS WARRANTY ,, Merchandise :or (cont'd) DOES NOT COVER: sold as reconditioned, used as rental equipment ,, Expendable parts or accessories supplied with the product inoperative or unusable after a reasonable period of use. or floor display models. which are expected to become ,, Merchandise that has become damaged or inoperative because of ordinary wear, misuse, cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident, failure to operate the product in accordance with the instructions provided in the Owner's Manual(s) supplied with the product, improper maintenance, the use of accessories attachments not recommended by GENTRON®, or unauthorized repair or alterations. • Repair and transportation - Costs assoiciated costs. costs of merchandise with assembly, determine not to be defective. required oil, adjustments or other installation or and start=up • Merchandise sold by GENTRON®, which has been manufactured by and identified as the product of another company, such as gasoline engines. The product manufacturer's warranty, if any, will apply. ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECTS, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT COVERED BY THIS WARRANTY. Some states do not allow the exclusion, so it may not apply to you. • IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. 4 Owner's Manual Safety Guidelines = Definitions This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These important Safety instructions! Read and understand all of these safety instructions. sure to retain them for future use. Be WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED. CAUTION: CAUTIONS iNDiCATE A POSSiBiLiTY OF EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT FOLLOWED. NOTE: NOTES GiVE HELPFUL INFORMATION WARNING! iMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING iNSTRUCTIONS BEFORE USING THIS EQUIPMENT. WHEN USING GENERATORS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RiSK OF PERSONAL iNJURY. 5 6000W General Propane Generator Precautions WARNING! FAILURE TO FOLLOW THESE iNSTRUCTiONS SEVERE iNJURY OR DEATH. CAN RESULT iN DANGER Carbon Using a generator indoors Monoxide WiLL KiLL YOU iN MINUTES. Carbon Monoxide Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even If you cannot smell the exhaust, you could be breathing CO. • NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air. • ONLY use a generator outdoors and far away from open windows, doors, and vents. These openings can pull in generator exhaust. Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning. Fuel and Oil This product requires oil and fuel. Attempting to start the engine without oil will ruin the engine and void the warranty. Work in well ventilated area. Keep cigarettes, flames or sparks away from the work area or where fuel is stored. A WARNING! PROPANE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS. KEEP OUT OF REACH OF CHILDREN. • Propane fuel and fumes are flammable and potentially explosive. Use proper fuel storage and handling procedures. Always have multiple ABC class fire extinguishers nearby. Keep the generator and surrounding area clean at all times. Fuel or oil spills must be cleaned up immediately. any local, state, or federal codes and regulations. Never store fuel or other flammable materials Dispose of fluids and cleaning materials as per Store oily rags in a covered metal container. near the generator. 6 OwneF s General Precautions al'lual (cont'd) Fuel and Oil (cont'd) • Do not smoke, or allow sparks, flames or other sources tank. Fuel vapors are explosive. of ignition around the engine and fuel Keep grounded conductive objects, such as tools, away from exposed, live electrical connections to avoid sparking or arcing. These events could ignite fumes or vapors. parts and Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not operate the generator with known leaks in the fuel system Excessive buildup of unburned fuel gases in the exhaust system can create a potentially explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the gases to dissipate before attempting to restart the generator. Use only engine manufacturer recommended fuel and oil. Hot Components WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY HOT AND REMAIN HOT FOR SOME TiME AFTER THE ENGINE IS RUN. WEAR iNSULATED GLOVES OR WAiT UNTIL THE ENGINE AND EXHAUST SYSTEM HAVE COOLED BEFORE HANDLING THESE PARTS. Power Output This generator is not designed to power sensitive electronic equipment (including computers and medical devices) without the addition of an approved line conditioner, which is sold separately. CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LiNE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. GENTRON® IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER. 7 6000W Propane General Precautions Generator (cont'd) Work Area + Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. + Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. + Keep bystanders, children, shields as needed. Electrical and visitors away while operating a generator. Provide barriers or Safety + Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. + Grounding provides a low-resistance path to carry electricity user in the event of an electrical malfunction. away from the + Double insulated tools are equipped with a polarized plug where one blade is wider than the other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in any way. Double insulation eliminates the need for the three-wire grounded power cord and grounded power supply system. + Avoid body contact with grounded surfaces such as pipes, radiators, There is an increased risk of electric shock if your body is grounded. • Do not expose generator risk of electric shock. to rain or wet conditions. ranges, and refrigerators. Water entering a generator will increase the + Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving parts. Replace damaged power cords immediately. Damaged power cords increase the risk of electric shock. + When operating a power tool outside, use an outdoor extension cord marked "W-A" or "W". These extension cords are rated for outdoor use, and reduce the risk of electric shock. 8 Owner's General Precautions Electrical Safety (cont'd) anual (cont'd) • All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. The generator must be earth-grounded for fixed installations in accordance electrical codes and standards before operation. Do not attempt soggy ground. to connect or disconnect load connections while standing with all relevant in water, or on wet or Do not touch electrically energized parts of the generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object. Connect the generator only to a load or electrical system (120 volt) that is compatible electrical characteristics and rated capacities of the generator. Before servicing input. equipment powered by the generator, disconnect the equipment with the from its power Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. Insulate all connections and disconnected wires. Guard against electric shock. Prevent body contact with grounded radiators, ranges, and refrigerator enclosures. Personal surfaces such as pipes, Safety Stay alert. Watch what you are doing, and use common sense when operating a generator. Do not use generator while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating generators may result in serious personal injury. Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. 9 6000W Pro ane Generator General Personal Precautions Safety (cont'd) (cont'd) = Avoid accidental starting. Make sure the power switch is in its "OFF" position, the spark plug wire when not in use. and disconnect • Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury. Do not overreach. Keep proper footing and balance at all times. Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. Do not force the generator. Use the correct generator for your application. will do the job better and safer at the rate for which it is designed. The correct Do not use the generator if the power switch does not turn it on or off. Any generator be controlled with the power switch is dangerous and must be replaced. Generator generator that cannot Use and Care Make sure the power switch is in its "OFF" position and disconnect the spark plug wire before making any adjustment, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally. Store idle generators out of reach of children dangerous in the hands of untrained users. Maintain generators use" until repaired. and other untrained with care. Do not use damaged persons. Generators generator. Tag damaged generators are "Do not Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator's operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained generators. Use only accessories that are recommended by the manufacturer for your model. Accessories may be suitable for one generator may become hazardous when used on another generator. 10 that Owner's General Precautions Manual (cont'd) Servicing Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact GENTRON® immediately for a replacement. Generator service must be performed only qualified repair personnel. performed by unqualified personnel could result in a risk of injury. Service or maintenance When servicing a generator, use only identical replacement parts. Follow all appropriate instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury. Heart Pacemakers WARNING! PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S} BEFORE USING THIS PRODUCT. ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE INTERFERENCE TO OR FAILURE OF THE PACEMAKER. Installation • Ensure installation meets all applicable safety, and local and national electrical codes. installation performed by a qualified, licensed electrician and building contractor. All electrical electrician. work, including the earth-ground connection, should be completed Any separate fuel storage or generator supply facility must be built or installed with all relevant local, state, and federal regulations. 11 Have by a licensed in full compliance 6000W Propane General Precautions installation Generator (cont'd) (cont'd) If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. should not be run outdoors without protection to the generator and wiring conduit. It • The generator weighs 201 Ibs (approx). Two or more people should assist when moving or lifting this product. Never lift the generator using the engine or alternator lifting lugs. Connect lifting equipment to the frame of the generator Before lifting the generator, ensure the lift rigging and supporting condition, and are rated to lift such a load. Keep all personnel away from the suspended generator structure are in good during relocating. The supporting floor/ground surface should be level and strong enough to safely hold the weight of the generator. If the floor/grounded surface is not level, strong cross members should be placed under the full length of the generator frame at its low side. For trailer installation, the generator should be mounted on the center point of the trailer, over the wheels. The trailer must be capable of supporting the weight of the generator and all contents (tools, etc.) Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping moisture within the generator's area. Mechanical Always make sure the power switch is in its "OFF" position. Disconnect allow the engine to completely cool before carrying out maintenance. the spark plug wire, and Check for damaged parts. Before using the generator, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any other condition that may affect proper operation technician. The generator is designed with guards for protection from moving parts. In any case, care must still be taken to protect personnel and equipment from other mechanical hazards when working around the generator. 12 Owner's General Precautions Mechanical anLlal (cont'd) (cont'd) • Do not operate the generator with safety guards removed. attempt to reach around the safety guard for maintenance While the generator is running, do not or any other reason. Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly. Keep access doors on enclosures closed and locked when access is not required. When working on or around the generator always wear protective approved safety gloves, safety eye goggles, and safety hat. Do not alter or adjust any part of the generator manufacturer. Always follow and complete scheduled that is assembled engine and generator clothing including and supplied ANSI by the maintenance. Chemicals Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces. Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, immediately wash with soap and water. For eye contact, immediately flush eyes with clean water and seek medical attention. Noise Prolonged exposure to noise levels above 68 DBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the generator when it is running. 13 General Precautions _cont'd) Extension Cord If an extension cord (not incnuded) is used, make sure to use onny UL approved correct gauge and Uength according to the foUlowing tame: Namepnate Amps {@ fuji moad) Oft,- 50ft, 0_5 16 Cord Lengths 50 ft,-i00 AWG ft. 16 Awe 100 ft,-150 72 ft. AWG 5.1 - 8 16 AWG 14 AWG 10 AWG 8.1 - 12 14 AWG 12 AWG - 10 AWG - 10 AWG - 12.1 - 15 15 - 20 cords having the 10 AWG 14 150 ft,-200 ft, 12AWe - - Owner's Manual Assembly Wheel and handle assembly: 1) CONTENTS: Spark plug Tool + Rod, 2 axles, 2 washers, 4 cotter pins, 2 wheels, Stand, 4 bolts 4 nuts, and Propane line. 2) Thread nut thru stand and frame of the generator. 3) Thread the nuts onto the bolts. 4) Install axle and push cotter pin thru hole in frame and axle. 5) Install wheel and washer. 6) Install cotter 15 pins. 6000W Pro ane Generator Assembly Wheel and handle assembly: 7) Handles should be already installed. 8) Twist and pull out to use handles. 16 Owner's ual To start this generator with th electric start you will need a battery (not included)_ You can use a 12v Lawn Tractor Battery with the following specifications: The dimensions are Wx7.5" DxS" Hx7"(including terminals). A rated cranking amperage of 200_ Terminals are regular, not reversed. Note: Using a battery not designed for this unit may void warranty. Also this generator can also be started with the pull start. Photos below demonstrate battery plate attachment. 1) Bolt on plate with M6X40 bolts as shown below. @ M6X40 2) Put the battery on the frame, have the battery assembled with the provided as shown. _7 accessories 6000W Pro ane Generator Propane Connection Propane hose connection Propane Cylinder (NOTE: This is your Propane Intake Valve common propane BBQ cylinder) Step 1 Step 2 Insert other end of hose to Insert hose connection to generator and tighten. Generator the propane Propane 18 Hose. (Included) cylinder & tighten. Owner's Manual Operation Purge button Outlets Voltage Fuel Intake Meter Valve Pull Start Key Start Key Start Circuit Breaker NOTE: THE PARTS LISTED ABOVE ARE HELPFUL CONTROLS MENTIONED BELOW. FOR LOCATING THE CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE FILLED WITH OIL OF A HIGH QUALITY SAE 10W=30 GRADE ENGINE OIL. TO DO SO, UNSCREW AND REMOVE THE ENGINE'S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE. FiLL THE ENGINE'S CRANKCASE UNTIL THE OiL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DiPSTiCK. THEN SCREW THE DiPSTiCK BACK iNTO THE OiL FiLL HOLE. Fuel intake Valve: Propane Pull Start: Manual start. Key Start: hose connection. Key start Key Start Circuit Breaker: Circuit Oil Fill: To check and fill oil. Voltage Meter: Measures Outlets: Plugs for appliances, breaker for key start. voltage etc. Hour Meter: Measures generator usage. Circuit Breaker: Breaker for outlets incase of overloads. Purge Button: To fill the generators lines with propane 19 when cold starting. 6000W Operation Propane Generator (cont'd) Starting Instructions Connect the propane hose from the bottle to the machine Pull the choke lever to the "START" Turn the fuel valve to the "START" Turn the valve on the propane cylinder all the way open position position Press the "PURGE" button for 3 seconds CONTINUEON NEXTPAGE 2O Owner's Operation anual (cont'd) Starting Instrections 0 Battery Start: If battery is installed, turn the key to the START position & allow the engine to crank. When engine starts, release the key back to the RUN position. Recoil Start: Turn the key to the RUN Position. Pull the recoil starter to start. Move the choke lever to the "RUN" Turn the fuel valve to the "RUN" position. position 21 6000W Propane Generator Operation Powering (cont'd) 120 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator's rated voltage, and amperage capacity (120VAC @ 42 AMPs) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator's capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LiNE CONDiTiONER MAY CAUSE DAMAGE TO THE EQUIPMENT. GENTRON® IS NOT RESPONSIBLE FOR ANY DIRECT OR iNDiRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LiNE CONDiTiONER. 2. Once the generator is running, simply connect the power cords of 120 volt AC powered tools and equipment into the 120 volt AC dual outlets. NOTE: THE GENERATOR FEATURES AN AC NON=FUSE CIRCUIT BREAKER TO PROTECT THE AC CIRCUIT iN CASE OF AN OVERLOAD. SHOULD AN OVERLOAD OCCUR, THE BREAKER WiLL "TRIP" TO iTS "OFF" POSiTiON. 3. Disconnect all electrical duel outlets. powered tools and equipment 4. After the engine and generator have completely location (if not already installed). For 120/240V According cooled, from the generator's store generator 120 volt AC in a safe, clean, dry Output to the diagram on the panel, you can adjust the wiring to have the output you need. Neutra! White GREE_/ Ground 22 OwneF s anual Operation (cont'd) Powering 120/240 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator's rated voltage, and amperage capacity (120V/240 AC @ 42/21 AMPs) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator's capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. CAUTION: ATTEMPTING TO POWER SENSiTiVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LiNE CONDiTiONER MAY CAUSE DAMAGE TO THE EQUIPMENT. GENTRON® iS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LiNE CONDiTiONER. 2. Once the generator is running, simply connect the power cords of 120/240 volt AC powered tools and equipment into the 120/240 volt AC dual outlets. NOTE: THE GENERATOR FEATURES AN AC NON=FUSE CiRCUiT BREAKER TO PROTECT THE AC CiRCUiT iN CASE OF AN OVERLOAD. SHOULD AN OVERLOAD OCCUR, THE BREAKER WiLL "TRIP" TO iTS "OFF" POSiTiON. 3. Disconnect all electrical duel outlets. powered tools and equipment 4. After the engine and generator have completely location (if not already installed). 23 cooled, from the generator's store generator 120/240 volt AC in a safe, clean, dry Propane Generator Operation (cont'd) Spark Plug Service in order to service the spark plug, you will need a spark plug wrench (commercially Recommended spark plugs: NHSP LD F7 RTC. To ensure proper engine operation, must be properly gapped and free of deposits. available). the spark plug 1. Remove the spark plug cap. 2. Use a spark plug wrench to remove the spark plug. 3. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 4. Measure the plug gap with a feeler gauge. 5. Check that the spark plug washer is in good condition. 6. After the spark plug is seated, tighten with a spark plug in by hand to prevent cross-threading. 7, After the spark plug is seated, tighten with a spark plug wrench to compress the washer. NOTE: THE SPARK PLUG MUST BE SECURELY TIGHTENED. AN IMPROPERLY TIGHTENED SPARK PLUG CAN BECOME VERY HOT AND COULD DAMAGE THE ENGINE. NEVER USE SPARK PLUGS WHICH HAVE AN IMPROPER HEAT RANGE. USE ONLY RECOMMENDED SPARK PLUGS OR EQUIVALENT. PLUG WRENCH / 24 OwneP s Rual inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH iS iN iTS "OFF" POSiTiON. DISCONNECT THE SPARK PLUG WiRE FROM THE ENGINE. AND ALLOW SUFFiCiENT TiME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY iNSPECTiONS, MAINTENANCE, OR CLEANING. = Before each use, inspect the generator. Check for: Loose screws Misaligned Cracked Damaged or binding moving parts or broken parts electrical Any other condition wiring that may affect safe operation. • If an engine problem occurs, have it checked Do not use damaged equipment. by a qualified service technician before further use. Before each use, make sure the engine's oil and fuel levels are adequate. If necessary, crankcase until the oil level is even with the oil hill hole and/or fill the fuel tank. fill the Before each use, remove all debris with a soft brush, rag, or vacuum. Lubricate all moving parts using a premium quality, lightweight machine oil. OIL FILL Every 50 hours of use, drain the old engine oil and replace with a high quality SAE 10W-30 grade engine oil. Upper Every 300 hours of use, have a qualified, certified technician perform thorough maintenance on the generator and engine. 25 Level 6000W Propane Generator Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR'S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY iS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNiT WiLL POWER. iF POWERING EXCEEDS THE GENERATOR'S CAPACITY, iT MAY BE NECCESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPERATE GENERATOR. Electrical and other permits may be required for the installation of emergency power systems. Investigate your local building and electrical codes before installing this unit. Installation must be completed by licensed contractors. WARNING! THE GENERATOR WEIGHS APPROXIMATELY 201 POUNDS. USE CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING iT TO THE INSTALLATION LOCATION. ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR. General Location • Make sure to locate and install the generator outdoors where cooling air is readily available. Install the generator so that the air inlets and outlets are not blocked by obstructions such as bushes, trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of a barrier for protection. In normal weather conditions, the air vent should face the prevailing wind direction. Install the generator not reach it. Generator placement on a concrete should slab or other area where rain drainage or flood waters can allow four feet of access to all sides for maintenance. 26 Owner's Installation Supporting anLlal (cont'd) and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8" diameter expansion anchor bolts (not supplied). Grounding NOTE: IT IS RECOMMENDED THAT ONLY A TRAINED ELECTRICIAN PERFORM THIS PROCEDURE AND LICENSED Connect a #6 AWG grounding wire (not included) from the ground connector on the generator power panel (picture below) to a grounding rod (picture below). It must be driven at least 24" deep into the earth (Soil). The grounding rod must be an earth-driven copper or brass (electrode) which can adequately ground the generator. I Ground Connector 27 Propane Generator Compliance UNITED STATES ENVIRONMENTAL WASHINGTON, DC 20460 2006 Model Year Certificate Manufacturer: JIANGSU PROTECTION AGENCY, of Conformity JIANGDONG GROUP CO. LTD. Small SI Engine Family: 6JDGS.3892LA Certificate Number: JDG-NRSI-06-06 HC+NO× FEL: g/kW-hr NIA Date Issued:SEP 0 8 2D35 Merrylin Zaw-Mon, Director, Compliance Transportation and Air Quality. and Innovation Strategies Division, Office of Pursuant to Section 213 of Clean Air Act (42 U.S.C. section 7547) and 40 CFR 90, and subject to the terms and conditions prescribed in those provisions, this certificate of conformity is hereby issued for the following small non-road engine family, more fully described in the documentation required by 40 CFR 90 and produced in the stated model year. This certificate of conformity covers only those new small non-road engines which conform in all material respects to the design specifications described in the documentation required by 40 CFR 90 and which are produced during the model year stated on this certificate. This certificate of conformity does not cover small non-road engines imported prior to the effective date of the certificate.SMALL NON-ROAD ENGINE FAMILY: 5JDGS.3892GA This certificate of conformity is conditional upon compliance of said manufacturer with the averaging, banking, and trading provisions of 40 CFR Part 90, Subpart C both during and after model year production. Failure to comply with these provisions may render this certificate void ab initio. The HC + NOX family emission limit (FEL) is: g/k W-hr. It is a term of this certificate that the manufacturer shall consent to all inspections described in 40 CFR 90.126 and 90.506 and authorized in a warrant or court order. Failure to comply with the requirements of such a warrant or court order may lead to revocation or suspension of this certificate for reasons specified in 40 CFR 90. It is also a term of this certificate that this certificate may be revoked or suspended or rendered void ab initio for other reasons specified in 40 CFR 90. This certificate does not cover small non-road engines sold, offered for sale, or introduced, or delivered for introduction, into commerce in the U.S. prior to the effective date of the certificate. 28 OwneP s anual Specifications AC electrical 120V/240V AC @ 42/21A 60Hz Current Output Continuous/Rated Wattage 5,000 Peak Wattage 6,000 Outlet Two 120VAC, 2 spring grounded One 120V twist-lock outlet One 120/240V AC twist-lock outlet Gasoline engine Horsepower 13 Type 4-cycle OHV air-cooled Displacement recoil & electric start 389cc Oil capacity 1.1 6 quart (1.1 liter) EPA approved yes Fuel Type Propane Fuel Capacity Running time 5 hrs 1/2 load (approx.) on 5 gal./201bs of fuel Fuel gauge none Weight Approximate weight 201 Ibs. 29 6000W Pro ane Generator Cylinder head system assy. (A) APA Parts No. Parts APG3560-A-01-JD No. Description JF340-A-01 HEAD COVER COMP. BOLT APG3560-A-02-J D J F340-A-02 HEAD COVER WASHER COME APG3560-A-03-J D J F340-A-03 WASHER COVER PACKING APG3560-A-04-J D J F340-A-04 HEAD COVER COME APG3560-A-05-J D J F340-A-05 HEAD COVER PACKING APG3560-A-06-J D J F340-A-06 FLANGE BOLT (al0x80) APG3560-A-07-J D J F340-A-07 SPARK PLUG JF340-A-08B EXHAUST PIPE STUD BOLT J F390-A-09 CYLINDER APG3560-A-10-JD JF340-A-10B CARBURETOR APG3560-A- 11-JD J F390-A- 11 CYLINDER APG3560-A-12-JD JF340-A-12 DOWEL PIN (q)10xq)12x20) APG3560-A-08-JD APG3560-A-09-J D 30 HEAD COMP. STUD BOLT HEAD SEALING PAD Cylinder barrel (B) 2 APA Parts No. Parts No. Description APG3560-B-01-JD JF340-B-01 FLANGE BOLT(M6x14) APG3560-B-02-JD JF240-B-02 OIL LEVELSWITCHASSY. APG3560-B-03-JD JF240-B-03 O-RING (14mm) APG3560-B-04-JD JF340-B-02 FLANGE NUT (MIO) APG3560-B-05-JD JF390-B-03 CRANK CASE APG3560-B-06-JD JF340-B-04 BALL BEARING(6207) APG3560-B-07-JD JF340-B-05 WASHER(q_8.3xr_17 xl) APG3560-B-08-JD JF340-B-06 LOCK PIN (10 mm) APG3560-B-09-JD JF340-B-07 GOVERNORARM SHAFT APG3560-B-10-JD JF340-B-08 OIL SEAL(_8x_14 x5) APG3560-B-1 I-JD JF340-B-09 DRAIN PLUG WASHER(12 mm) APG3560-B-12-JD JF340-B-10 DRAIN PLUG BOLT APG3560-B- 13-JD JF340-B-11 OIL SEAL(_35 x_52 x8) APG3560-B-14-JD JF340-B-12 OIL PROTECTOR APG3560-B-15-JD JF340-B-13 BALL BEARING(6202) 31 6000W Pro ane Generator Crankcase cover system assy(C) 3 14 t5 2_ APA Parts No. APG3560-C-01-JD APG3560-C-02-JD APG3560-C-03-JD APG3560-C-04-JD Parts No. JD5000-A-01 J D5000-A-02 JF340-C-03B JF340-C-02 APG3560-C-05-JD APG3560-C-06-JD APG3560-C-07-JD APG3560-C-08-JD APG3560-C-09-JD APG3560-C-10-JD APG3560-C-11-JD APG3560-C-12-JD APG3560-C-13-JD APG3560-C-14-JD APG3560-C-15-JD APG3560-C-16-JD JF340-B-11 JF390-C-01 JF340-C-04B JF340-C-06 JF340-C-07 JF340-C-05 JF340-C-08 JF340-C-09 JF340-B-13 J F340- B-04 J F340-C- 10 J F240-C- 11 Description DUCT COVER FLANGE BOLT (M8x35) OI L SCALE OIL SCALE SEAL RING OIL SEAL (q)35xcp52x8) FLANGE BOLT (M8x35) CRANKCASE COVER GOVERNOR GEAR WASHER (6 mm) GOVERNOR GEAR SLIDER SHAFT SLIDER WASHER (6 mm) GOVERNOR SLIDER BALL BEARING (6202) BALL BEARING (6207) CRANKCASE COVER PAD DOWEL PIN (8x12) 32 Crankshaft system assy(D) i APA Parts No. Parts No. APG3560-D-01-JD JF340-D-02 APG3560-D-02-JD JF340-D-04 Description CRANKSHAFTCOMR BALANCERWEIGHT 88 6000W Pro ane Generator Piston and connecting (E) 10 5 APA Parts No. Parts No. APG3560-E-O1-JD JF390-E-01 APG3560-E-O2-JD JF390-E-02 APG3560-E-O3-JD JF390-E-03 APG3560-E-O4-JD JF390-E-04 APG3560-E-O5-JD APG3560-E-O6-JD APG3560-E-O7-JD APG3560-E-OS-JD APG3560-E-O9-JD APG3560-E-10-JD JF240-E-05 JF390-E-05 JF390-E-06 JF340-E-07 JF340-E-08 JF340-E-09 Description COMPRESSIONRINGA COMPRESSIONRING B OIL RINGA OIL RINGB PISTONPIN CLIP (20 mm) PISTON PISTONPIN CONNECTING ROD CONNECTING COVER CONNECTING ROD BOLT 34 .1 Camshaft system assy(F) , 7 It!i @ APA Parts No. APG3560-F-01-JD APG3560-F-02-JD APG3560-F-03-JD APG3560-F-04-JD APG3560-F-05-JD APG3560-F-06-JD APG3560-F-07-JD APG3560-F-08-JD APG3560-F-09-JD APG3560-F-10-JD APG3560-F-11-JD APG3560-F-12-JD APG3560-F-13-JD APG3560-F-14-JD APG3560-F-15-JD Pa_s No. JF340-F-01 JF340-F-02 JF340-F-03 JF340-F-04 JF340-F-05 JF240-F-06 JF240-F-07 JF390-F-08 JF340-F-06 JF340-F-07 JF340-F-08 JF340-F-09 JF340-F-lO JF340-F-11 JF340-F-12 APG3560-F-16-JD N/A Description PIVOT ADJUSTING NUT ROCKER ARM PIVOT ROCKER ARM PIVOT BOLT (M8) PUSH ROD GUIDE PLATE ROD PUSH INTAKE VALVE EX VALVE VALVE SPRING INTAKE VALVE SPRING RETAINER EX VALVE SPRING RETAINER EX VALVE HELMET PUSH ROD GUIDE PLATE ROCKER BOLT LOCK NUT ROCKER ARM ASSY. 35 6000W Pro ane Generator Recoil starter system assy(G) / APA Parts No. Parts No. Description RECOILSTARTERASSY. SETTINGSCREW SPRINGRETAINER PLATENSPRING STARTERDETENT DETENTSPRING RECOILSTARTERREEL STARTRETURNSPRING RECOILSTARTERCASECOMP. APG3560-G-01-JD JF340-G-01 APG3560-G-02-JD JF340-G-02 APG3S60-G-03-JD JF340-G-03 APG3S60-G-04-JD JF340-G-04 APG3S60-G-0S-JD JF340-G-05 APG3S60-G-06-JD JF340-G-06 APG3S60-G-07-JD JF340-G-07 APG3560-G-08-JD APG3S60-G-09-JD JF340-G-08 JF340-G-09 APG3560-G-10-JD APG3560-G- 11-JD JF340-G-10 JF340-G-11 RECOILSTARTERROPE STARTERKNOB APG3560-G-12-JD JF340-G-12 FLANGE BOLT (M6 xS) 36 Fan cover system assy(H) 4 24 ¸ _2 APA Parts No. Parts No. APG3560-H-O1-JD JF340-H-01 APG3560-H-O2-JD APG3560-H-O3-JD APG3560-H-O4-JD Description SHROUD JF340-H-02 JF340-H-03 JF340-H-04 FLANGE BOLT(M6 x 14) FAN COVERCOMP. WIRE HARNESSCLIP 37 6000W Propane Generator Carburetor system assy.(I) @ 8 1 7 12 16 APA Parts No. APG3560-1-01-JD APG3560-1-02-JD APG3560-1-03-JD APG3560-1-04-JD APG3560-1-05-JD APG3560-1-06-JD APG3560-1-07-JD APG3560-1-08-JD APG3560-1-09-JD APG3560-1-10-JD APG3560-1-11-JD APG3560-1-12-JD Parts No. JD3800-B-01 JD3800-B-02 JD3800-B-03 JD3800-B-04 JD3800-B-05 JD3800-B-06 JF340-1-05 JF390LPG-I-01 JF340-1-03 JF340-1-02B JF340-1-01 JF200LPG-I-09 Description TUBE CLIP TUBEA TUBE B WIPE HARNESS CLIP DASHPOT CHECK VALVE MANUAL CHOKE STAYASSY. CARBURETOR IRON GASKET MIXER CARBURETOR PAPER GASKET CARBURETOR INSULATING PLATE INTAKE PIPE GASKET AIRPROOF GASKET APG3560-1-13-JD APG3560-1-14-JD APG3560-1-15-JD JF390LPG-I-02 JF390LPG-I-03 JF200LPG-I-04 APG3560-1-16-JD APG3560-1-17-JD JF200LPG-I-03 JF200LPG-I-05 LOW PRESSURE PIPE DECOMPRESSION VALVE ELECTROMAGNETIC VALVE INTAKE TIE-IN HIGH PRESSURE PIPE 38 Flywheel system Assy(J) 6 APA Parts No. Parts No. APG3560-J-O1-JD JF340-J-01A APG3560-J-O2-JD JF340-J-01B APG3560-J-O3-JD JF340-J-02 APG3560-J-O4-JD JF340-J-03 APG3560-J-OS-JD JF340-J-04 APG3560-J-O6-JD JF340-J-05 Description FLYWHEEL FLYWHEEL SEMICIRCLEKEY COOLING FAN STARTERPULLEY FLYWHEELNUT (M16) 39 6000W Pro ane Generator Ignition System Assy(K) 9 APA Parts No. Parts No. APG3560-K-O1-JD JF340-K-01 APG3560-K-02-JD JF340-K-02 APG3560-K-O3-JD JF340-K-03 APG3560-K-O4-JD JF340-K-04 Description NOISESUPPERSSORCAP ASSY. INGITION GOILASSY. STOP SWITCHCORD STOP SWITCHCORD HOLDER APG3560-K-OS-JD APG3560-K-O6-JD APG3560-K-O7-JD JF340-K-05 JF340-K-06 JF340-K-07 FLANGE BOLT(M6×25) CORD GROMMET CHARGECOIL ASSY. APG3560-K-O8-JD JF340-K-08 FLANGE BOLT(M6×40) APG3560-K-Og-JD JF340-K-09 CORD CLAMPER APG3560-K-10-JD JF340-K-10 FLANGE BOLT(M6×20) 4O StartermotorSystem assy(L) 1 3 APA Parts No. APG3560-L-O1-JD APG3560-L-O2-JD APG3560-L-03-JD Parts No. JF340-L-01 JF340-L-02 Description UNIT STARTERMOTOR CONTACTOR ASSY. JF340-L-03 FLANGE BOLT (M8x35) 41 6000W Pro ane Generator Control APA Parts No. Parts No. APG3560-M-O1-JD JF340-M-OIB APG3560-M-O2-JD JF340-M-O2B APG3560-M-O3-JD JF340-M-03 APG3560-M-O4-JD JF340-M-04 APG3560-M-O5-JD JF340-M-05 APG3560-M-O6-JD JF340-M-06 APG3560-M-O7-JD JF340-M-07 APG3560-M-O8-JD JF340-M-08 APG3560-M-Og-JD JF340-M-09 APG3560-M-10-JD JF340-M-10 APG3560-M- 11-JD JF340-M-11 System Assy(M) Description CONTROLASSY. CONTROL BASECOMP. CONTROLADJUSTING SPRING PAN SCREW(M5 x34) FLANGE BOLT(M6x14) GOVERNORSPRING THROTTLERETURNSPRING GOVERNORROD FLANGE NUT (M6) GOVERNORARM BOLT(M6) CONTROL ARM 42 Muffler System Assy. (N) @ APA APG3560-N-01-JD Parts No. Parts No. JD3800-B-01 Description FLANGE BOLT (M8×16) APG3560-N-02-JD JD3800-B-02 FLANGE BOLT (M6x12) APG3560-N-03-JD JD3800-B-03 MUFFLER STAY COME APG3560-N-04-JD JD3800-B-04 MUFFLER APG3560-N-05-JD JD3800-B-05 MUFFLER SIDE PROTECTOR APG3560-N-06-JD JD6500-A-01 MUFFLER INNER PROTECTOR APG3560-N-07-JD JD6500-A-02 JD3800-B-08 MUFFLER COUP. MUFFLER OUTER PROTECTOR APG3560-N-10-JD JD3800-B-09 JD3800-B-10 EX. PIPE GASKET EX .PIPE COME APG3560-N-11-JD JD3800-B-11 FLANGE BOLT (M8x25) APG3560-N-12-JD APG3560-N-13-JD JD3800-B-12 JD6500-A-03 FLANGE NUT (IV18) MUFFLERASSY. APG3560-N-08-JD APG3560-N-09-JD 43 PROTECTOR SEAL COME COUP. 6000W Pro ane Generator Air cleaner(O) 9 APA Parts No. APG3560-O-01-JD APG3560-O-02-JD APG3560-O-03-JD APG3560-O-04-JD APG3560-O-05-JD APG3560-O-06-JD APG3560-O-07-JD APG3560-O-08-JD APG3560-O-09-JD APG3560-O-10-JD Parts No. JD3800-C-0i JD3800-C-02 JD3800-C-03 JD3800-C-04 JD3800-C-05 JD3800-C-06 J F340-A- 13 B JD3800-C-07 JD3800-C-08 JD3800-C-09 Description AIR CLEANER AIR CLEANER COVER COMP ELEMENT FLANGE NUT (M5) AIR CLEANER SEPARATOR AIR CLEANER SEAL AIR CLEANER CASE COMP BREATHER TUBE FLANGE NUT (M6) AIR CLEANER STAY AI R CLEANER ASSY. 44 m Owner's Manual Control panel (P) 3 4 7 _ 5 8 _9 APA Parts No. Parts No. Description APG3560-P-01 -JD APG3560-P-02-JD APG3560-P-03-JD APG3560-P-04-JD APG3560-P-05-JD APG3560-P-06-JD APG3560-P-07-JD APG3560-P-08-JD APG3560-P-09-JD JF200LPG-I-0 JD6500ELPG-A-01 JD6500BST-E-04 ELECTROMAGNETICVALVE SWITCHASSY. ENGINE SWITCH ASSY. VOLT METER ASSY. CIRCUIT BREAKER JD6500LPG-A-02 JD6500BST-E-08 JD6500BST-E-07 JD6500BST-E-05 JD6500LPG-A-03 120V/240V RECEPTACLE (L14-30) 120V RECEPTACLE (L5-30) 120V RECEPTACLE (Ru-22) TIME WATCH JD6500BST-E-09 EARTH TERMINAL 45 SET 6000W Pro ane Generator Frame(Q) 10 APA Parts No. APG3560-Q-01 -JD APG3560-Q-02-JD APG3560-Q-03-JD APG3560-Q-04-JD APG3560-Q-05-JD APG3560-Q-06-JD APG3560-Q-07-JD APG3560-Q-08-JD Parts No. JD6500ELPG-B-01 JD3800-F-05 Description FRAME COMR BOTTOM RUBBER JD3800-F-04 JD6500LPG-B-02 JD3500LPG-C-03 JD3500LPG-B-04 JD6500LPG-B-03 JD3500LPG-B-06 FLANGE NUT (M8) ARC COVER FLANGE BOLT (M6X12) FLANGE NUT (M6) COPING FIX FRAME 46 ,i Owner's Manual Rotor Stator 3 17 APA Parts No. Parts No. Description APG3560-R-O1-JD JD6500-D-01 APG3560-R-O2-JD APG3560-R-O3-JD APG3560-R-O4-JD APG3560-R-OS-JD APG3560-R-O6-JD APG3560-R-O7-JD APG3560-R-OS-JD APG3560-R-O9-JD APG3560-R-10-JD APG3560-R-1I-JD APG3560-R-12-JD APG3560-R-13-JD APG3560-R-14-JD APG3560-R-15-JD APG3560-R-16-JD APG3560-R-17-JD APG3560-R-18-JD APG3560-R-19-JD APG3560-R-20-JD APG3560-R-21-JD APG3560-R-22-JD APG3560-R-23-JD JD6500-D-02 STATOR ASSY. JD6500-G-03 COOLING FAN JD3800-G-04 BRUSH ASSY. JD3800-G-05 TAPPING SCREW (MS x14) JD3800-G-06 RR HOUSING JD3800-G-07 PAN SCREW (MSx12) JD6500-G-08 FLANGE BOLT (M6x179) STATOR COVER JD6500-G-09 AUTOMATIC VOLTAGE REGULATOR ASSY. JD3800-G-I 0 GENERATOR COVER JD3800-G-I I CABLE TIE JD3800-G-I 2 FLANGE BOLT (MSx12) JD3800-G-I 4 BEARING ASSY. JD3800-G-I 5 PLAIN WASHER JD6500-D-03 ROTOR COMP. JD6500-D-04 FLANGE BOLT (MI0 x265) JD6500-D-05 FLANGE BOLT (MSx214) JD3800-G-I 8 HEX.BOLT (MS x20) JD3800-G-I 9 VOLT CHANGE TERMINAL BR-AC-W JD3800-G-20 PLAIN WASHER (Smm) JD3800-G-21 HEX. NUT (MS) JD3800-G-22 SPRING WASHER (Smm) JD3800-G-23 CRANK CASE GROMMET 47
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 48 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Sat Mar 29 01:22:47 2014 Author : Title : Subject :EXIF Metadata provided by EXIF.tools