Gentron GG6000P User Manual GENERATOR Manuals And Guides 1107415L

User Manual: Gentron GG6000P GG6000P GENTRON GENERATOR - Manuals and Guides View the owners manual for your GENTRON GENERATOR #GG6000P. Home:Tool Parts:Gentron Parts:Gentron GENERATOR Manual

Open the PDF directly: View PDF PDF.
Page Count: 48

DownloadGentron GG6000P User Manual  GENERATOR - Manuals And Guides 1107415L
Open PDF In BrowserView PDF
I EN

I RON

Owner's
6OOOW

®

Manual

PROPANI-

(_ENERATOR

P|easeread Slidsavethese|listruet|elis,
HAVEOUESTIOHS
ORHEEDSERVICE
DO HOTRETURNTOSTORE!

PL_SE CALLTOLLFREE,"
888.896.6881

www.

GentronUSA.

com

G
Carbon
Using a generator

Monoxide

indoors

WILL

KiLL YOU iN MINUTES.

Carbon

Monoxide

Generator exhaust contains high levels of carbon monoxide (CO), a poisonous
gas you cannot see or smell. If you can smell the generator exhaust, you are
breathing CO. But even If you cannot smell the exhaust, you could be breathing
CO.
• NEVER use a generator inside homes, garages, crawlspaces,
or other partly
enclosed areas. Deadly levels of carbon monoxide can build up in these areas.
Using a fan or opening windows and doors does NOT supply enough fresh air.
• ONLY use a generator outdoors and far away from open windows,
vents. These openings can pull in generator exhaust.

doors, and

Even when you use a generator correctly, CO may leak into the home. ALWAYS
use a battery-powered
or battery-backup
CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running,
move to fresh air RIGHT AWAY. See a doctor. You could have carbon
monoxide

poisoning.

6000W Pro ane Generator
Table of Contents

Topic

Page

Limited Warrant

3

Safety Guidelines

5

General Precautions

6

Assembly

15

Battery

17

Propane Connection

18

Operation/Starting

19

Inspection,

Generator

Cleaning and Maintenance

25

Installation

26

Compliance

28

Specifications

29

Part Lists

30

WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS
IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH
INSTRUCTIONS
IN THIS MANUAL COULD RESULT IN PERSONAL
INJURY, PROPERTY DAMAGE, AND/OR VOIDING OF YOUR
WARRANTY.
GENTRON® WILL NOT BE LIABLE FOR ANY
DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS.

2

Owner's

anual

Limited Warranty
GENTRON® warrants to the original purchaser who uses the product in a consumer
application (personal, residential or household usage) that all products covered under this
warranty are free from defects in material and workmanship
for one year from the date of
purchase. All products covered by this limited warranty which are used in commercial applications
(i.e. income producing) are warranted to be free of defects in material and workmanship
for
90 days from the date of original purchase. Products covered under this warranty include air
compressors,
air tools, service parts, pressure washers and generators.
GENTRON®
components
to the normal
replacement
final.

will repair or replace, at GENTRON® sole option, products or
which have failed within the warranty period. Service will be scheduled according
work flow and business hours at the service center location, and the availability of
parts. All decisions of GENTRON® with regard to this limited warranty shall be

This warranty gives you specific
state to state.
RESPONSIBILITY

legal rights, and you may also have other rights which vary from

OF ORIGINAL PURCHASER

(initial User):

To process a warranty claim on this product, DO NOT return item to the retailer. The product must
be evaluated by an Authorized Warranty Service Center. For the location of the nearest Authorized
Warranty Service Center call toll free 888.896.6881.
Retain original cash register
Use reasonable
Manual(s).

sales receipt

care in the operation

Deliver or ship the product
be paid by the purchaser.

as proof

and maintenance

to the Authorized

Warranty

of purchase

for warranty

of the product

as described

in the Owner's

Service Center. Freight costs, if any must

If the purchaser does not receive satisfactory results form the Authorized
Center, the purchaser should contact GENTRON@.

3

to work.

Warranty

Service

6000W Propane Gener;
Limited Warranty
THIS WARRANTY
,, Merchandise

:or

(cont'd)

DOES NOT COVER:

sold as reconditioned,

used as rental equipment

,, Expendable parts or accessories supplied with the product
inoperative or unusable after a reasonable period of use.

or floor display models.

which are expected

to become

,, Merchandise that has become damaged or inoperative because of ordinary wear, misuse,
cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence,
accident, failure to operate the product in accordance with the instructions provided in the
Owner's Manual(s) supplied with the product, improper maintenance, the use of accessories
attachments not recommended
by GENTRON®,
or unauthorized repair or alterations.
• Repair and transportation
- Costs assoiciated
costs.

costs of merchandise

with assembly,

determine

not to be defective.

required oil, adjustments

or other installation

or

and start=up

• Merchandise sold by GENTRON®,
which has been manufactured
by and identified as the
product of another company, such as gasoline engines. The product manufacturer's
warranty,
if any, will apply.
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL
LOSS, DAMAGE, OR EXPENSE THAT
MAY RESULT FROM ANY DEFECTS, FAILURE OR MALFUNCTION OF THE PRODUCT IS
NOT COVERED BY THIS WARRANTY. Some states do not allow the exclusion, so it may not
apply to you.
• IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY
OR FITNESS FOR
A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL
PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the
above limitations may not apply to you.

4

Owner's Manual
Safety Guidelines = Definitions
This manual contains important information that you need to know and
understand in order to protect YOUR SAFETY and to PREVENT
EQUIPMENT PROBLEMS. The following symbols help you recognize this
information. Please read the manual and pay attention to these sections.

Save These important

Safety instructions!

Read and understand all of these safety instructions.
sure to retain them for future use.

Be

WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG
POSSIBILITY
OF PERSONAL INJURY OR DEATH IF
INSTRUCTIONS
ARE NOT FOLLOWED.

CAUTION: CAUTIONS iNDiCATE A POSSiBiLiTY
OF
EQUIPMENT DAMAGE IF INSTRUCTIONS
ARE NOT
FOLLOWED.

NOTE: NOTES GiVE HELPFUL

INFORMATION

WARNING! iMPROPER OPERATION OR MAINTENANCE
OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY
AND PROPERTY DAMAGE. READ AND UNDERSTAND
ALL
WARNINGS AND OPERATING iNSTRUCTIONS
BEFORE USING
THIS EQUIPMENT. WHEN USING GENERATORS,
BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RiSK OF PERSONAL iNJURY.

5

6000W
General

Propane

Generator

Precautions
WARNING! FAILURE TO FOLLOW THESE iNSTRUCTiONS
SEVERE iNJURY OR DEATH.

CAN RESULT iN

DANGER
Carbon
Using

a generator

indoors

Monoxide
WiLL

KiLL

YOU

iN MINUTES.

Carbon Monoxide
Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see
or smell. If you can smell the generator exhaust, you are breathing CO. But even If you cannot smell
the exhaust, you could be breathing CO.
• NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly
levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors
does NOT supply enough fresh air.
• ONLY use a generator outdoors and far away from open windows, doors, and vents. These
openings can pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home. ALWAYS use a
battery-powered
or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT
AWAY. See a doctor. You could have carbon monoxide poisoning.

Fuel and Oil
This product requires oil and fuel. Attempting to start the engine without oil will ruin
the engine and void the warranty. Work in well ventilated area. Keep cigarettes,
flames or sparks away from the work area or where fuel is stored.

A

WARNING! PROPANE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE
UNDER CERTAIN CONDITIONS.
KEEP OUT OF REACH OF CHILDREN.

• Propane fuel and fumes are flammable and potentially explosive. Use proper fuel storage and
handling procedures. Always have multiple ABC class fire extinguishers
nearby.
Keep the generator

and surrounding

area clean at all times.

Fuel or oil spills must be cleaned up immediately.
any local, state, or federal codes and regulations.
Never store fuel or other flammable

materials

Dispose of fluids and cleaning materials as per
Store oily rags in a covered metal container.

near the generator.
6

OwneF s
General

Precautions

al'lual

(cont'd)

Fuel and Oil (cont'd)
• Do not smoke, or allow sparks, flames or other sources
tank. Fuel vapors are explosive.

of ignition around the engine and fuel

Keep grounded conductive objects, such as tools, away from exposed, live electrical
connections to avoid sparking or arcing. These events could ignite fumes or vapors.

parts and

Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not
operate the generator with known leaks in the fuel system
Excessive buildup of unburned fuel gases in the exhaust system can create a potentially
explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or
hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the
gases to dissipate before attempting to restart the generator.
Use only engine manufacturer

recommended

fuel and oil.

Hot Components
WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY
HOT AND REMAIN HOT FOR SOME TiME AFTER THE ENGINE IS RUN. WEAR
iNSULATED GLOVES OR WAiT UNTIL THE ENGINE AND EXHAUST SYSTEM
HAVE COOLED BEFORE HANDLING THESE PARTS.

Power Output
This generator is not designed to power sensitive electronic equipment (including computers
and medical devices) without the addition of an approved line conditioner, which is sold separately.
CAUTION: ATTEMPTING
TO POWER SENSITIVE ELECTRONIC
EQUIPMENT
WITHOUT THE USE OF AN APPROVED LiNE CONDITIONER
MAY CAUSE
DAMAGE TO THE EQUIPMENT. GENTRON® IS NOT RESPONSIBLE
FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LINE CONDITIONER.

7

6000W

Propane

General Precautions

Generator

(cont'd)

Work Area
+ Keep your work area clean and well lit. Cluttered

benches and dark areas invite accidents.

+ Do not operate power tools in explosive atmospheres, such as in the presence of flammable
liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes.
+ Keep bystanders, children,
shields as needed.

Electrical

and visitors

away while operating

a generator.

Provide barriers

or

Safety

+ Grounded tools must be plugged into an outlet properly installed and
grounded in accordance with all codes and ordinances. Never remove the
grounding prong or modify the plug in any way. Do not use any adapter
plugs.
+ Grounding provides a low-resistance
path to carry electricity
user in the event of an electrical malfunction.

away from the

+ Double insulated tools are equipped with a polarized plug where one blade is wider than the
other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet.
Do not change the plug in any way. Double insulation eliminates the need for the three-wire
grounded power cord and grounded power supply system.
+ Avoid body contact with grounded surfaces such as pipes, radiators,
There is an increased risk of electric shock if your body is grounded.
• Do not expose generator
risk of electric shock.

to rain or wet conditions.

ranges, and refrigerators.

Water entering a generator

will increase the

+ Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving
parts. Replace damaged power cords immediately. Damaged power cords increase the risk of
electric shock.
+ When operating a power tool outside, use an outdoor extension cord marked "W-A" or "W".
These extension cords are rated for outdoor use, and reduce the risk of electric shock.

8

Owner's
General

Precautions

Electrical

Safety (cont'd)

anual

(cont'd)

• All connections and conduits from the generator to the load must only be installed by trained and
licensed electricians, and in compliance with all relevant local, state, and federal electrical
codes and standards, and other regulations where applicable.
The generator must be earth-grounded
for fixed installations in accordance
electrical codes and standards before operation.
Do not attempt
soggy ground.

to connect

or disconnect

load connections

while standing

with all relevant

in water, or on wet or

Do not touch electrically energized parts of the generator and interconnecting cables or
conductors with any part of the body, or with any non-insulated
conductive object.
Connect the generator only to a load or electrical system (120 volt) that is compatible
electrical characteristics
and rated capacities of the generator.
Before servicing
input.

equipment

powered

by the generator,

disconnect

the equipment

with the

from its power

Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked,
cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded.
Keep terminals clean and tight.
Insulate all connections

and disconnected

wires.

Guard against electric shock. Prevent body contact with grounded
radiators, ranges, and refrigerator enclosures.

Personal

surfaces such as pipes,

Safety

Stay alert. Watch what you are doing, and use common sense when operating a generator. Do
not use generator while tired or under the influence of drugs, alcohol, or medication. A moment
of inattention while operating generators may result in serious personal injury.
Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing,
and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in
moving parts.

9

6000W Pro ane Generator
General
Personal

Precautions
Safety

(cont'd)

(cont'd)

= Avoid accidental starting. Make sure the power switch is in its "OFF" position,
the spark plug wire when not in use.

and disconnect

• Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is
left attached to a rotating part of the generator may result in personal injury.
Do not overreach.

Keep proper footing and balance at all times.

Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye
goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for
appropriate conditions.
Do not force the generator. Use the correct generator for your application.
will do the job better and safer at the rate for which it is designed.

The correct

Do not use the generator if the power switch does not turn it on or off. Any generator
be controlled with the power switch is dangerous and must be replaced.

Generator

generator

that cannot

Use and Care

Make sure the power switch is in its "OFF" position and disconnect the spark plug wire before
making any adjustment, changing accessories, or storing the generator. Such preventive safety
measures reduce the risk of starting the generator accidentally.
Store idle generators out of reach of children
dangerous in the hands of untrained users.
Maintain generators
use" until repaired.

and other untrained

with care. Do not use damaged

persons.

Generators

generator. Tag damaged

generators

are

"Do not

Check for misalignment or binding of moving parts, breakage of parts, and any other condition that
may affect the generator's operation. If damaged, have the generator serviced before using. Many
accidents are caused by poorly maintained generators.
Use only accessories that are recommended
by the manufacturer for your model. Accessories
may be suitable for one generator may become hazardous when used on another generator.

10

that

Owner's
General

Precautions

Manual

(cont'd)

Servicing
Maintain labels and name plates on the generator and engine. These carry important information.
If unreadable or missing, contact GENTRON® immediately for a replacement.
Generator service must be performed only qualified repair personnel.
performed by unqualified personnel could result in a risk of injury.

Service or maintenance

When servicing a generator, use only identical replacement parts. Follow all appropriate
instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions
may create a risk of electric shock or injury.

Heart Pacemakers
WARNING!

PEOPLE WITH PACEMAKERS

SHOULD

CONSULT

THEIR

PHYSICIAN(S} BEFORE USING THIS PRODUCT. ELECTROMAGNETIC
FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE
INTERFERENCE
TO OR FAILURE OF THE PACEMAKER.

Installation
• Ensure installation meets all applicable safety, and local and national electrical codes.
installation performed by a qualified, licensed electrician and building contractor.
All electrical
electrician.

work, including

the earth-ground

connection,

should be completed

Any separate fuel storage or generator supply facility must be built or installed
with all relevant local, state, and federal regulations.

11

Have

by a licensed

in full compliance

6000W

Propane

General Precautions
installation

Generator

(cont'd)

(cont'd)

If the generator is installed outdoors, it must be weatherproofed
and should be soundproofed.
should not be run outdoors without protection to the generator and wiring conduit.

It

• The generator weighs 201 Ibs (approx). Two or more people should assist when moving or lifting
this product. Never lift the generator using the engine or alternator lifting lugs. Connect lifting
equipment to the frame of the generator
Before lifting the generator, ensure the lift rigging and supporting
condition, and are rated to lift such a load.
Keep all personnel

away from the suspended

generator

structure

are in good

during relocating.

The supporting floor/ground surface should be level and strong enough to safely hold the weight
of the generator. If the floor/grounded
surface is not level, strong cross members should be
placed under the full length of the generator frame at its low side.
For trailer installation, the generator should be mounted on the center point of the trailer, over
the wheels. The trailer must be capable of supporting the weight of the generator and all
contents (tools, etc.)
Install sound-and weather-proofing
only when it is not raining or snowing to avoid trapping
moisture within the generator's area.

Mechanical
Always make sure the power switch is in its "OFF" position. Disconnect
allow the engine to completely cool before carrying out maintenance.

the spark plug wire, and

Check for damaged parts. Before using the generator, any part that appears damaged should
be carefully checked to determine that it will operate properly and perform its intended function.
Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any
other condition that may affect proper operation technician.
The generator is designed with guards for protection from moving parts. In any case, care must
still be taken to protect personnel and equipment from other mechanical hazards when working
around the generator.

12

Owner's
General Precautions
Mechanical

anLlal

(cont'd)

(cont'd)

• Do not operate the generator with safety guards removed.
attempt to reach around the safety guard for maintenance

While the generator is running, do not
or any other reason.

Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that
when engine parts are moving fast they cannot be seen clearly.
Keep access doors on enclosures

closed and locked when access is not required.

When working on or around the generator always wear protective
approved safety gloves, safety eye goggles, and safety hat.
Do not alter or adjust any part of the generator
manufacturer.
Always follow and complete

scheduled

that is assembled

engine and generator

clothing

including

and supplied

ANSI

by the

maintenance.

Chemicals
Avoid contact

with hot fuel, oil, exhaust fumes, and hot solid surfaces.

Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek
medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact,
immediately wash with soap and water. For eye contact, immediately flush eyes with clean water
and seek medical attention.

Noise
Prolonged exposure to noise levels above 68 DBA is hazardous to hearing. Always wear ANSI
approved ear protection when operating or working around the generator when it is running.

13

General

Precautions

_cont'd)

Extension Cord
If an extension cord (not incnuded) is used, make sure to use onny UL approved
correct gauge and Uength according to the foUlowing tame:
Namepnate Amps {@
fuji moad)

Oft,- 50ft,
0_5

16

Cord Lengths

50 ft,-i00
AWG

ft.

16

Awe

100 ft,-150
72

ft.

AWG

5.1 - 8

16 AWG

14 AWG

10 AWG

8.1 - 12

14 AWG

12 AWG

-

10 AWG

-

10 AWG

-

12.1 - 15
15 - 20

cords having the

10 AWG

14

150 ft,-200 ft,
12AWe

-

-

Owner's Manual
Assembly
Wheel and handle assembly:

1) CONTENTS:
Spark plug Tool +
Rod, 2 axles, 2 washers, 4 cotter
pins, 2 wheels, Stand, 4 bolts 4
nuts, and Propane line.

2) Thread nut thru stand and
frame of the generator.

3) Thread the nuts onto the bolts.

4) Install axle and push cotter pin thru
hole in frame and axle.

5) Install wheel and washer.

6) Install cotter

15

pins.

6000W Pro ane Generator
Assembly
Wheel and handle assembly:

7) Handles should

be already

installed.

8) Twist and pull out to use handles.

16

Owner's

ual

To start this generator with th electric start you will need a battery (not included)_ You can use a
12v Lawn Tractor Battery with the following specifications: The dimensions are
Wx7.5" DxS" Hx7"(including terminals). A rated cranking amperage of 200_ Terminals
are regular, not reversed. Note: Using a battery not designed for this unit may void warranty.
Also this generator can also be started with the pull start.

Photos below demonstrate

battery

plate attachment.

1) Bolt on plate with M6X40 bolts as shown below.

@

M6X40
2) Put the battery on the frame, have the battery assembled with the provided
as shown.

_7

accessories

6000W Pro ane Generator
Propane Connection
Propane

hose connection

Propane Cylinder
(NOTE: This is your

Propane
Intake Valve

common propane
BBQ cylinder)

Step 1

Step 2

Insert other end of hose to

Insert hose connection to
generator and tighten.

Generator

the propane

Propane
18

Hose. (Included)

cylinder

& tighten.

Owner's

Manual

Operation
Purge button

Outlets
Voltage

Fuel Intake

Meter

Valve

Pull Start

Key Start

Key Start
Circuit Breaker

NOTE: THE PARTS LISTED ABOVE ARE HELPFUL
CONTROLS MENTIONED
BELOW.

FOR LOCATING

THE

CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE
FILLED WITH OIL OF A HIGH QUALITY SAE 10W=30 GRADE ENGINE OIL.
TO DO SO, UNSCREW AND REMOVE THE ENGINE'S OIL DIPSTICK LOCATED
AT THE BOTTOM OF THE ENGINE CRANKCASE. FiLL THE ENGINE'S
CRANKCASE UNTIL THE OiL LEVEL IS LEVEL WITH THE UPPER MARKED
LINE ON THE DiPSTiCK. THEN SCREW THE DiPSTiCK BACK iNTO
THE OiL FiLL HOLE.

Fuel intake Valve: Propane
Pull Start: Manual start.
Key Start:

hose connection.

Key start

Key Start Circuit Breaker: Circuit
Oil Fill: To check and fill oil.
Voltage

Meter:

Measures

Outlets:

Plugs for appliances,

breaker

for key start.

voltage
etc.

Hour Meter: Measures generator usage.
Circuit Breaker: Breaker for outlets incase of overloads.
Purge

Button:

To fill the generators

lines with propane

19

when cold starting.

6000W
Operation

Propane

Generator

(cont'd)

Starting Instructions

Connect the propane hose from the
bottle to the machine

Pull the choke lever to the "START"

Turn the fuel valve to the "START"

Turn the valve on the propane cylinder
all the way open

position

position

Press the "PURGE" button for
3 seconds

CONTINUEON NEXTPAGE
2O

Owner's
Operation

anual

(cont'd)

Starting Instrections

0
Battery Start: If battery is installed, turn the key to the START position & allow
the engine to crank. When engine starts, release the key back to the RUN position.
Recoil Start: Turn the key to the RUN Position. Pull the recoil starter to start.

Move the choke lever to the "RUN"

Turn the fuel valve to the "RUN"

position.

position

21

6000W Propane Generator
Operation
Powering

(cont'd)

120 Volt AC Tools And Equipment:

1. Prior to powering tools and equipment, make sure the generator's rated voltage, and amperage
capacity (120VAC @ 42 AMPs) is adequate to supply all electrical loads that the unit will
power. If powering exceeds the generator's capacity, it may be necessary to group one or more
of the tools and/or equipment for connection to a separate generator.
CAUTION: ATTEMPTING
TO POWER SENSITIVE ELECTRONIC
EQUIPMENT
WITHOUT THE USE OF AN APPROVED LiNE CONDiTiONER
MAY CAUSE
DAMAGE TO THE EQUIPMENT. GENTRON®
IS NOT RESPONSIBLE
FOR ANY DIRECT OR iNDiRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LiNE CONDiTiONER.
2. Once the generator is running, simply connect the power cords of 120 volt AC powered
tools and equipment into the 120 volt AC dual outlets.

NOTE: THE GENERATOR FEATURES AN AC NON=FUSE CIRCUIT BREAKER TO
PROTECT THE AC CIRCUIT iN CASE OF AN OVERLOAD. SHOULD AN OVERLOAD
OCCUR, THE BREAKER WiLL "TRIP" TO iTS "OFF" POSiTiON.

3. Disconnect all electrical
duel outlets.

powered

tools and equipment

4. After the engine and generator have completely
location (if not already installed).

For 120/240V
According

cooled,

from the generator's

store generator

120 volt AC

in a safe, clean, dry

Output

to the diagram

on the panel, you can adjust the wiring to have the output you need.

Neutra!
White

GREE_/
Ground

22

OwneF s

anual

Operation (cont'd)
Powering

120/240 Volt AC Tools And Equipment:

1. Prior to powering tools and equipment, make sure the generator's rated voltage, and amperage
capacity (120V/240 AC @ 42/21 AMPs) is adequate to supply all electrical loads that the unit will
power. If powering exceeds the generator's capacity, it may be necessary to group one or more
of the tools and/or equipment for connection to a separate generator.
CAUTION: ATTEMPTING
TO POWER SENSiTiVE
ELECTRONIC
EQUIPMENT
WITHOUT THE USE OF AN APPROVED LiNE CONDiTiONER
MAY CAUSE
DAMAGE TO THE EQUIPMENT.
GENTRON® iS NOT RESPONSIBLE
FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LiNE CONDiTiONER.
2. Once the generator is running, simply connect the power cords of 120/240 volt AC powered
tools and equipment into the 120/240 volt AC dual outlets.

NOTE: THE GENERATOR FEATURES AN AC NON=FUSE CiRCUiT BREAKER TO
PROTECT THE AC CiRCUiT iN CASE OF AN OVERLOAD. SHOULD AN OVERLOAD
OCCUR, THE BREAKER WiLL "TRIP" TO iTS "OFF" POSiTiON.

3. Disconnect all electrical
duel outlets.

powered

tools and equipment

4. After the engine and generator have completely
location (if not already installed).

23

cooled,

from the generator's

store generator

120/240 volt AC

in a safe, clean, dry

Propane Generator
Operation (cont'd)
Spark Plug Service
in order to service the spark plug, you will need a spark plug wrench (commercially
Recommended
spark plugs: NHSP LD F7 RTC. To ensure proper engine operation,
must be properly gapped and free of deposits.

available).
the spark plug

1. Remove the spark plug cap.
2. Use a spark plug wrench to remove the spark plug.
3. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark
plug with a wire brush if it is to be reused.
4. Measure the plug gap with a feeler gauge.
5. Check that the spark plug washer is in good condition.
6. After the spark plug is seated, tighten with a spark plug in by hand to prevent cross-threading.
7, After the spark plug is seated, tighten with a spark plug wrench to compress the washer.
NOTE: THE SPARK PLUG MUST BE SECURELY TIGHTENED. AN IMPROPERLY
TIGHTENED SPARK PLUG CAN BECOME VERY HOT AND COULD DAMAGE THE
ENGINE. NEVER USE SPARK PLUGS WHICH HAVE AN IMPROPER HEAT RANGE.
USE ONLY RECOMMENDED SPARK PLUGS OR EQUIVALENT.

PLUG WRENCH

/

24

OwneP s

Rual

inspection, Cleaning, and
Maintenance
WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH iS iN iTS
"OFF" POSiTiON. DISCONNECT
THE SPARK PLUG WiRE FROM THE ENGINE.
AND ALLOW SUFFiCiENT TiME FOR THE ENGINE AND GENERATOR TO
COMPLETELY COOL BEFORE PERFORMING ANY iNSPECTiONS,
MAINTENANCE,
OR CLEANING.
= Before each use, inspect the generator.

Check for:

Loose screws
Misaligned
Cracked
Damaged

or binding

moving parts

or broken parts
electrical

Any other condition

wiring
that may affect safe operation.

• If an engine problem occurs, have it checked
Do not use damaged equipment.

by a qualified service technician

before further use.

Before each use, make sure the engine's oil and fuel levels are adequate. If necessary,
crankcase until the oil level is even with the oil hill hole and/or fill the fuel tank.

fill the

Before each use, remove all debris with a soft brush, rag, or vacuum.
Lubricate all moving parts using a premium
quality, lightweight machine oil.

OIL FILL

Every 50 hours of use, drain the old engine oil
and replace with a high quality
SAE 10W-30 grade engine oil.
Upper

Every 300 hours of use, have a qualified, certified
technician perform thorough maintenance on the
generator and engine.

25

Level

6000W

Propane

Generator

Installation
NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE
SURE THE GENERATOR'S RATED VOLTAGE, WATTAGE AND AMPERAGE
CAPACITY iS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS
THAT THE UNiT WiLL POWER. iF POWERING EXCEEDS THE GENERATOR'S
CAPACITY, iT MAY BE NECCESSARY TO GROUP ONE OR MORE OF THE
TOOLS AND/OR EQUIPMENT FOR CONNECTION
TO A
SEPERATE GENERATOR.
Electrical and other permits may be required for the installation of emergency power systems.
Investigate your local building and electrical codes before installing this unit. Installation must be
completed by licensed contractors.
WARNING! THE GENERATOR WEIGHS APPROXIMATELY
201 POUNDS. USE
CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING
iT TO THE INSTALLATION LOCATION. ALWAYS CONNECT HOIST LINES TO
THE FRAME OF THE GENERATOR.

General

Location

• Make sure to locate and install the generator

outdoors

where cooling

air is readily available.

Install the generator so that the air inlets and outlets are not blocked by obstructions such as
bushes, trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require
the placement of a barrier for protection. In normal weather conditions, the air vent should face
the prevailing wind direction.
Install the generator
not reach it.
Generator

placement

on a concrete

should

slab or other area where rain drainage

or flood waters can

allow four feet of access to all sides for maintenance.

26

Owner's
Installation
Supporting

anLlal

(cont'd)

and Mounting

Mount the generator on a concrete slab capable of supporting the weight of the generator. The
slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor
for slab specifications
if necessary. Attach the frame to the concrete slab using 3/8" diameter
expansion anchor bolts (not supplied).

Grounding
NOTE: IT IS RECOMMENDED
THAT ONLY A TRAINED
ELECTRICIAN
PERFORM THIS PROCEDURE

AND LICENSED

Connect a #6 AWG grounding wire (not included) from the ground connector on the
generator power panel (picture below) to a grounding rod (picture below). It must be driven
at least 24" deep into the earth (Soil). The grounding rod must be an earth-driven
copper or
brass (electrode) which can adequately ground the generator.

I
Ground

Connector

27

Propane Generator
Compliance
UNITED STATES ENVIRONMENTAL
WASHINGTON, DC 20460
2006 Model Year Certificate
Manufacturer:

JIANGSU

PROTECTION AGENCY,

of Conformity

JIANGDONG

GROUP CO. LTD.

Small SI Engine Family: 6JDGS.3892LA
Certificate
Number: JDG-NRSI-06-06
HC+NO× FEL: g/kW-hr NIA
Date Issued:SEP 0 8 2D35
Merrylin Zaw-Mon, Director, Compliance
Transportation
and Air Quality.

and Innovation Strategies

Division, Office of

Pursuant to Section 213 of Clean Air Act (42 U.S.C. section 7547) and 40 CFR 90, and subject to
the terms and conditions prescribed in those provisions, this certificate of conformity is hereby
issued for the following small non-road engine family, more fully described in the documentation
required by 40 CFR 90 and produced in the stated model year.
This certificate of conformity covers only those new small non-road engines which conform in
all material respects to the design specifications
described in the documentation
required by 40
CFR 90 and which are produced during the model year stated on this certificate. This certificate
of conformity does not cover small non-road engines imported prior to the effective date of the
certificate.SMALL
NON-ROAD ENGINE FAMILY: 5JDGS.3892GA

This certificate of conformity is conditional upon compliance of said manufacturer with the
averaging, banking, and trading provisions of 40 CFR Part 90, Subpart C both during and after
model year production. Failure to comply with these provisions may render this certificate void ab
initio. The HC + NOX family emission limit (FEL) is: g/k W-hr.
It is a term of this certificate that the manufacturer shall consent to all inspections described in
40 CFR 90.126 and 90.506 and authorized in a warrant or court order. Failure to comply with
the requirements of such a warrant or court order may lead to revocation or suspension of this
certificate for reasons specified in 40 CFR 90. It is also a term of this certificate that this certificate
may be revoked or suspended or rendered void ab initio for other reasons specified in 40 CFR 90.
This certificate does not cover small non-road engines sold, offered for sale, or introduced, or
delivered for introduction,
into commerce in the U.S. prior to the effective date of the certificate.

28

OwneP s

anual

Specifications
AC electrical
120V/240V AC @ 42/21A 60Hz

Current Output
Continuous/Rated

Wattage

5,000

Peak Wattage

6,000

Outlet
Two 120VAC, 2 spring grounded
One 120V twist-lock outlet
One 120/240V AC twist-lock outlet

Gasoline

engine
Horsepower

13

Type

4-cycle

OHV air-cooled

Displacement

recoil & electric start

389cc

Oil capacity

1.1 6 quart (1.1 liter)

EPA approved

yes

Fuel
Type

Propane Fuel

Capacity
Running time

5 hrs 1/2 load (approx.) on 5 gal./201bs of fuel

Fuel gauge

none

Weight
Approximate

weight

201 Ibs.

29

6000W Pro ane Generator
Cylinder head system assy. (A)

APA Parts

No.

Parts

APG3560-A-01-JD

No.

Description

JF340-A-01

HEAD COVER COMP. BOLT

APG3560-A-02-J

D

J F340-A-02

HEAD COVER WASHER COME

APG3560-A-03-J

D

J F340-A-03

WASHER COVER PACKING

APG3560-A-04-J

D

J F340-A-04

HEAD COVER COME

APG3560-A-05-J

D

J F340-A-05

HEAD COVER PACKING

APG3560-A-06-J

D

J F340-A-06

FLANGE BOLT (al0x80)

APG3560-A-07-J

D

J F340-A-07

SPARK PLUG

JF340-A-08B

EXHAUST PIPE STUD BOLT

J F390-A-09

CYLINDER

APG3560-A-10-JD

JF340-A-10B

CARBURETOR

APG3560-A- 11-JD

J F390-A- 11

CYLINDER

APG3560-A-12-JD

JF340-A-12

DOWEL PIN (q)10xq)12x20)

APG3560-A-08-JD
APG3560-A-09-J

D

30

HEAD COMP.
STUD BOLT

HEAD SEALING PAD

Cylinder barrel (B)

2

APA Parts No.

Parts No.

Description

APG3560-B-01-JD

JF340-B-01

FLANGE BOLT(M6x14)

APG3560-B-02-JD

JF240-B-02

OIL LEVELSWITCHASSY.

APG3560-B-03-JD

JF240-B-03

O-RING (14mm)

APG3560-B-04-JD

JF340-B-02

FLANGE NUT (MIO)

APG3560-B-05-JD

JF390-B-03

CRANK CASE

APG3560-B-06-JD

JF340-B-04

BALL BEARING(6207)

APG3560-B-07-JD

JF340-B-05

WASHER(q_8.3xr_17 xl)

APG3560-B-08-JD

JF340-B-06

LOCK PIN (10 mm)

APG3560-B-09-JD

JF340-B-07

GOVERNORARM SHAFT

APG3560-B-10-JD

JF340-B-08

OIL SEAL(_8x_14 x5)

APG3560-B-1 I-JD

JF340-B-09

DRAIN PLUG WASHER(12 mm)

APG3560-B-12-JD

JF340-B-10

DRAIN PLUG BOLT

APG3560-B- 13-JD

JF340-B-11

OIL SEAL(_35 x_52 x8)

APG3560-B-14-JD

JF340-B-12

OIL PROTECTOR

APG3560-B-15-JD

JF340-B-13

BALL BEARING(6202)

31

6000W Pro ane Generator
Crankcase cover system assy(C)
3

14

t5

2_

APA Parts No.
APG3560-C-01-JD
APG3560-C-02-JD
APG3560-C-03-JD
APG3560-C-04-JD

Parts No.
JD5000-A-01
J D5000-A-02
JF340-C-03B
JF340-C-02

APG3560-C-05-JD
APG3560-C-06-JD
APG3560-C-07-JD
APG3560-C-08-JD
APG3560-C-09-JD
APG3560-C-10-JD
APG3560-C-11-JD
APG3560-C-12-JD
APG3560-C-13-JD
APG3560-C-14-JD
APG3560-C-15-JD
APG3560-C-16-JD

JF340-B-11
JF390-C-01
JF340-C-04B
JF340-C-06
JF340-C-07
JF340-C-05
JF340-C-08
JF340-C-09
JF340-B-13
J F340- B-04
J F340-C- 10
J F240-C- 11

Description
DUCT COVER
FLANGE BOLT (M8x35)
OI L SCALE
OIL SCALE SEAL RING
OIL SEAL (q)35xcp52x8)
FLANGE BOLT (M8x35)
CRANKCASE COVER
GOVERNOR GEAR WASHER (6 mm)
GOVERNOR GEAR
SLIDER SHAFT
SLIDER WASHER (6 mm)
GOVERNOR SLIDER
BALL BEARING (6202)
BALL BEARING (6207)
CRANKCASE COVER PAD
DOWEL PIN (8x12)

32

Crankshaft system assy(D)

i

APA Parts No.
Parts No.
APG3560-D-01-JD
JF340-D-02
APG3560-D-02-JD
JF340-D-04

Description
CRANKSHAFTCOMR
BALANCERWEIGHT

88

6000W Pro ane Generator
Piston and connecting

(E)

10

5

APA Parts No.
Parts No.
APG3560-E-O1-JD
JF390-E-01
APG3560-E-O2-JD
JF390-E-02
APG3560-E-O3-JD
JF390-E-03
APG3560-E-O4-JD
JF390-E-04
APG3560-E-O5-JD
APG3560-E-O6-JD
APG3560-E-O7-JD
APG3560-E-OS-JD
APG3560-E-O9-JD
APG3560-E-10-JD

JF240-E-05
JF390-E-05
JF390-E-06
JF340-E-07
JF340-E-08
JF340-E-09

Description
COMPRESSIONRINGA
COMPRESSIONRING B
OIL RINGA
OIL RINGB
PISTONPIN CLIP (20 mm)
PISTON
PISTONPIN
CONNECTING ROD
CONNECTING COVER
CONNECTING ROD BOLT

34

.1

Camshaft system assy(F)

,

7

It!i
@

APA Parts No.
APG3560-F-01-JD
APG3560-F-02-JD
APG3560-F-03-JD
APG3560-F-04-JD
APG3560-F-05-JD
APG3560-F-06-JD
APG3560-F-07-JD
APG3560-F-08-JD
APG3560-F-09-JD
APG3560-F-10-JD
APG3560-F-11-JD
APG3560-F-12-JD
APG3560-F-13-JD
APG3560-F-14-JD
APG3560-F-15-JD

Pa_s No.
JF340-F-01
JF340-F-02
JF340-F-03
JF340-F-04
JF340-F-05
JF240-F-06
JF240-F-07
JF390-F-08
JF340-F-06
JF340-F-07
JF340-F-08
JF340-F-09
JF340-F-lO
JF340-F-11
JF340-F-12

APG3560-F-16-JD

N/A

Description
PIVOT ADJUSTING NUT
ROCKER ARM PIVOT
ROCKER ARM
PIVOT BOLT (M8)
PUSH ROD GUIDE PLATE
ROD PUSH
INTAKE VALVE
EX VALVE
VALVE SPRING
INTAKE VALVE SPRING RETAINER
EX VALVE SPRING RETAINER
EX VALVE HELMET
PUSH ROD GUIDE PLATE
ROCKER BOLT
LOCK NUT
ROCKER ARM ASSY.

35

6000W Pro ane Generator
Recoil starter system assy(G)

/
APA Parts No.

Parts No.

Description
RECOILSTARTERASSY.
SETTINGSCREW
SPRINGRETAINER
PLATENSPRING
STARTERDETENT
DETENTSPRING
RECOILSTARTERREEL
STARTRETURNSPRING
RECOILSTARTERCASECOMP.

APG3560-G-01-JD

JF340-G-01

APG3560-G-02-JD

JF340-G-02

APG3S60-G-03-JD

JF340-G-03

APG3S60-G-04-JD

JF340-G-04

APG3S60-G-0S-JD

JF340-G-05

APG3S60-G-06-JD

JF340-G-06

APG3S60-G-07-JD

JF340-G-07

APG3560-G-08-JD
APG3S60-G-09-JD

JF340-G-08
JF340-G-09

APG3560-G-10-JD
APG3560-G- 11-JD

JF340-G-10
JF340-G-11

RECOILSTARTERROPE
STARTERKNOB

APG3560-G-12-JD

JF340-G-12

FLANGE BOLT (M6 xS)

36

Fan cover system assy(H)
4

24 ¸
_2

APA Parts No.
Parts No.
APG3560-H-O1-JD
JF340-H-01
APG3560-H-O2-JD
APG3560-H-O3-JD
APG3560-H-O4-JD

Description
SHROUD

JF340-H-02
JF340-H-03
JF340-H-04

FLANGE BOLT(M6 x 14)
FAN COVERCOMP.
WIRE HARNESSCLIP

37

6000W Propane Generator
Carburetor

system assy.(I)

@

8

1

7

12

16

APA Parts No.
APG3560-1-01-JD
APG3560-1-02-JD
APG3560-1-03-JD
APG3560-1-04-JD
APG3560-1-05-JD
APG3560-1-06-JD
APG3560-1-07-JD
APG3560-1-08-JD
APG3560-1-09-JD
APG3560-1-10-JD
APG3560-1-11-JD
APG3560-1-12-JD

Parts No.
JD3800-B-01
JD3800-B-02
JD3800-B-03
JD3800-B-04
JD3800-B-05
JD3800-B-06
JF340-1-05
JF390LPG-I-01
JF340-1-03
JF340-1-02B
JF340-1-01
JF200LPG-I-09

Description
TUBE CLIP
TUBEA
TUBE B
WIPE HARNESS CLIP
DASHPOT CHECK VALVE
MANUAL CHOKE STAYASSY.
CARBURETOR IRON GASKET
MIXER
CARBURETOR PAPER GASKET
CARBURETOR INSULATING PLATE
INTAKE PIPE GASKET
AIRPROOF GASKET

APG3560-1-13-JD
APG3560-1-14-JD
APG3560-1-15-JD

JF390LPG-I-02
JF390LPG-I-03
JF200LPG-I-04

APG3560-1-16-JD
APG3560-1-17-JD

JF200LPG-I-03
JF200LPG-I-05

LOW PRESSURE PIPE
DECOMPRESSION
VALVE
ELECTROMAGNETIC
VALVE
INTAKE TIE-IN
HIGH PRESSURE PIPE
38

Flywheel

system Assy(J)

6

APA Parts No.
Parts No.
APG3560-J-O1-JD
JF340-J-01A
APG3560-J-O2-JD
JF340-J-01B
APG3560-J-O3-JD
JF340-J-02
APG3560-J-O4-JD
JF340-J-03
APG3560-J-OS-JD
JF340-J-04
APG3560-J-O6-JD
JF340-J-05

Description
FLYWHEEL
FLYWHEEL
SEMICIRCLEKEY
COOLING FAN
STARTERPULLEY
FLYWHEELNUT (M16)

39

6000W Pro ane Generator
Ignition

System Assy(K)

9
APA Parts No.
Parts No.
APG3560-K-O1-JD
JF340-K-01
APG3560-K-02-JD
JF340-K-02
APG3560-K-O3-JD
JF340-K-03
APG3560-K-O4-JD
JF340-K-04

Description
NOISESUPPERSSORCAP ASSY.
INGITION GOILASSY.
STOP SWITCHCORD
STOP SWITCHCORD HOLDER

APG3560-K-OS-JD
APG3560-K-O6-JD
APG3560-K-O7-JD

JF340-K-05
JF340-K-06
JF340-K-07

FLANGE BOLT(M6×25)
CORD GROMMET
CHARGECOIL ASSY.

APG3560-K-O8-JD

JF340-K-08

FLANGE BOLT(M6×40)

APG3560-K-Og-JD

JF340-K-09

CORD CLAMPER

APG3560-K-10-JD

JF340-K-10

FLANGE BOLT(M6×20)

4O

StartermotorSystem
assy(L)
1

3

APA Parts No.
APG3560-L-O1-JD
APG3560-L-O2-JD
APG3560-L-03-JD

Parts No.
JF340-L-01
JF340-L-02

Description
UNIT STARTERMOTOR
CONTACTOR ASSY.

JF340-L-03

FLANGE BOLT (M8x35)

41

6000W Pro ane Generator
Control

APA Parts No.
Parts No.
APG3560-M-O1-JD
JF340-M-OIB
APG3560-M-O2-JD
JF340-M-O2B
APG3560-M-O3-JD
JF340-M-03
APG3560-M-O4-JD
JF340-M-04
APG3560-M-O5-JD
JF340-M-05
APG3560-M-O6-JD
JF340-M-06
APG3560-M-O7-JD
JF340-M-07
APG3560-M-O8-JD
JF340-M-08
APG3560-M-Og-JD
JF340-M-09
APG3560-M-10-JD
JF340-M-10
APG3560-M- 11-JD
JF340-M-11

System Assy(M)

Description
CONTROLASSY.
CONTROL BASECOMP.
CONTROLADJUSTING SPRING
PAN SCREW(M5 x34)
FLANGE BOLT(M6x14)
GOVERNORSPRING
THROTTLERETURNSPRING
GOVERNORROD
FLANGE NUT (M6)
GOVERNORARM BOLT(M6)
CONTROL ARM

42

Muffler System Assy. (N)

@

APA

APG3560-N-01-JD

Parts

No.

Parts
No.
JD3800-B-01

Description
FLANGE BOLT (M8×16)

APG3560-N-02-JD

JD3800-B-02

FLANGE BOLT (M6x12)

APG3560-N-03-JD

JD3800-B-03

MUFFLER STAY COME

APG3560-N-04-JD

JD3800-B-04

MUFFLER

APG3560-N-05-JD

JD3800-B-05

MUFFLER SIDE PROTECTOR

APG3560-N-06-JD

JD6500-A-01

MUFFLER INNER PROTECTOR

APG3560-N-07-JD

JD6500-A-02
JD3800-B-08

MUFFLER COUP.
MUFFLER OUTER PROTECTOR

APG3560-N-10-JD

JD3800-B-09
JD3800-B-10

EX. PIPE GASKET
EX .PIPE COME

APG3560-N-11-JD

JD3800-B-11

FLANGE BOLT (M8x25)

APG3560-N-12-JD
APG3560-N-13-JD

JD3800-B-12
JD6500-A-03

FLANGE NUT (IV18)
MUFFLERASSY.

APG3560-N-08-JD

APG3560-N-09-JD

43

PROTECTOR SEAL
COME
COUP.

6000W Pro ane Generator
Air cleaner(O)

9

APA Parts No.
APG3560-O-01-JD
APG3560-O-02-JD
APG3560-O-03-JD
APG3560-O-04-JD
APG3560-O-05-JD
APG3560-O-06-JD
APG3560-O-07-JD
APG3560-O-08-JD
APG3560-O-09-JD
APG3560-O-10-JD

Parts No.
JD3800-C-0i
JD3800-C-02
JD3800-C-03
JD3800-C-04
JD3800-C-05
JD3800-C-06
J F340-A- 13 B
JD3800-C-07
JD3800-C-08
JD3800-C-09

Description
AIR CLEANER
AIR CLEANER

COVER COMP
ELEMENT

FLANGE NUT (M5)
AIR CLEANER SEPARATOR
AIR CLEANER SEAL
AIR CLEANER CASE COMP
BREATHER TUBE
FLANGE NUT (M6)
AIR CLEANER STAY
AI R CLEANER ASSY.

44

m

Owner's Manual
Control panel (P)
3

4

7

_

5

8

_9

APA Parts No.

Parts No. Description

APG3560-P-01 -JD
APG3560-P-02-JD
APG3560-P-03-JD
APG3560-P-04-JD
APG3560-P-05-JD
APG3560-P-06-JD
APG3560-P-07-JD
APG3560-P-08-JD
APG3560-P-09-JD

JF200LPG-I-0
JD6500ELPG-A-01
JD6500BST-E-04

ELECTROMAGNETICVALVE SWITCHASSY.
ENGINE SWITCH ASSY.
VOLT METER ASSY.
CIRCUIT BREAKER

JD6500LPG-A-02
JD6500BST-E-08
JD6500BST-E-07
JD6500BST-E-05
JD6500LPG-A-03

120V/240V RECEPTACLE (L14-30)
120V RECEPTACLE (L5-30)
120V RECEPTACLE (Ru-22)
TIME WATCH

JD6500BST-E-09

EARTH TERMINAL

45

SET

6000W Pro ane Generator
Frame(Q)

10

APA Parts No.
APG3560-Q-01 -JD
APG3560-Q-02-JD
APG3560-Q-03-JD
APG3560-Q-04-JD
APG3560-Q-05-JD
APG3560-Q-06-JD
APG3560-Q-07-JD
APG3560-Q-08-JD

Parts No.
JD6500ELPG-B-01
JD3800-F-05

Description
FRAME COMR
BOTTOM RUBBER

JD3800-F-04
JD6500LPG-B-02
JD3500LPG-C-03
JD3500LPG-B-04
JD6500LPG-B-03
JD3500LPG-B-06

FLANGE NUT (M8)
ARC COVER
FLANGE BOLT (M6X12)
FLANGE NUT (M6)
COPING
FIX FRAME

46

,i

Owner's Manual
Rotor Stator

3

17

APA Parts No.

Parts No.

Description

APG3560-R-O1-JD

JD6500-D-01

APG3560-R-O2-JD
APG3560-R-O3-JD
APG3560-R-O4-JD
APG3560-R-OS-JD
APG3560-R-O6-JD
APG3560-R-O7-JD
APG3560-R-OS-JD
APG3560-R-O9-JD
APG3560-R-10-JD
APG3560-R-1I-JD
APG3560-R-12-JD
APG3560-R-13-JD
APG3560-R-14-JD
APG3560-R-15-JD
APG3560-R-16-JD
APG3560-R-17-JD
APG3560-R-18-JD
APG3560-R-19-JD
APG3560-R-20-JD
APG3560-R-21-JD
APG3560-R-22-JD
APG3560-R-23-JD

JD6500-D-02

STATOR ASSY.

JD6500-G-03

COOLING FAN

JD3800-G-04

BRUSH ASSY.

JD3800-G-05

TAPPING SCREW (MS x14)

JD3800-G-06

RR HOUSING

JD3800-G-07

PAN SCREW (MSx12)

JD6500-G-08

FLANGE BOLT (M6x179)

STATOR COVER

JD6500-G-09

AUTOMATIC VOLTAGE REGULATOR ASSY.

JD3800-G-I

0

GENERATOR COVER

JD3800-G-I

I

CABLE TIE

JD3800-G-I

2

FLANGE BOLT (MSx12)

JD3800-G-I

4

BEARING ASSY.

JD3800-G-I

5

PLAIN WASHER

JD6500-D-03

ROTOR COMP.

JD6500-D-04

FLANGE BOLT (MI0 x265)

JD6500-D-05

FLANGE BOLT (MSx214)

JD3800-G-I

8

HEX.BOLT (MS x20)

JD3800-G-I

9

VOLT CHANGE TERMINAL BR-AC-W

JD3800-G-20

PLAIN WASHER (Smm)

JD3800-G-21

HEX. NUT (MS)

JD3800-G-22

SPRING WASHER (Smm)

JD3800-G-23

CRANK CASE GROMMET

47



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 48
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Sat Mar 29 01:22:47 2014
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu