Gilbarco GBIRA Radio Frequency Identification Device User Manual
Gilbarco Inc. Radio Frequency Identification Device
Gilbarco >
installation instructions
MDE-3801 TRIND™ MULTI 1 Transmitter/Receiver in Dispenser Retrofit Kits C00012-001-XX Installation Introduction Purpose of this Manual This manual provides instruction for installing TRIND™ Multi 1 Retrofit Kits in The Advantage® Series wide frame and narrow frame units with InfoScreen®, monochrome CRIND®, or single-line CRIND. The TRIND option allows customers to automatically authorize CRIND-equipped units using a hand-held transponder tag provided by a major oil company (MOC). Use this kit for one- or two-sided units. Prerequisites Before installing the TRIND kit, ensure that the existing CRIND has the Z-180 logic board T17764-XX, which is not provided in TRIND retrofit kit. Important Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment. Required Reading Before installing the equipment, the installer must read, understand, and follow: • this manual • NFPA 30A, The Automotive and Marine Service Station Code • NFPA 70, The National Electric Code • applicable federal, state and local codes and regulations Failure to do so may adversely effect the safe use and operation of the equipment. Note: This kit must be installed by a Gilbarco ASC (Authorized Service Contractor) to insure warranty. Related Documents MDE-2531 MDE-2562 MDE-2628 MDE-2620 PT-1728 PT-1736 Pump & Dispenser Start-Up & Service Manual CRIND Service Manual Cash Acceptor Retrofit Assemblies for The Advantage Series with CRIND Graphics Panel Application for The Advantage Series The Advantage Series Illustrated Parts Manual CRIND Card Reader Illustrated Parts Manual MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 1 Introduction Required Tools The following equipment is needed to install all TRIND™ Multi 1 kits • Allen wrench set, American standard • clean cloth or rag • chip extraction tool, e.g., IC extraction, Digikey Part No. K158-ND or equivalent • isopropyl alcohol (part# END-1082) • needle nose pliers • nut driver, 1/4'', 3/8'' • pocket knife • Q12534 CRIND diagnostic card • ratchet set, standard • screwdrivers, flat and Phillips head • static guard wrist strap The following additional tools are required if kit is to be installed on wide frame units with call or stop button on existing right options door. • center punch • deburring tool or round file • hand drill, battery electric or pneumatic • light hammer • pilot drill bit (between 3/32” and 1/4”) and 7/8” drill bit • standard tape measure or rule Page 2 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Parts Lists Parts Lists Kits for Wide Frame Units, Dual- and Single-Sided Kits C00012-001-WF-D (dual-sided) and C00012-001-WF-S (single-sided) for The Advantage Wide Frames (48’’) contain the following parts. Description Part Number Quantity WF-D Kit Quantity WF-S Kit cable clamp, gray Q13558-04 cable group Q13781-01 cable tie Q10178-02 card cage assembly T20538-G1 door assembly, right options clear with TRIND T20537-G1 T50148-G1 (see note) (see note) grommet strip, solid Q10315-06 .583 ft. .583 ft. jump jack Q11011-01 10 10 label plate, FCC N23936-01 manual, graphics installation instructions MDE-2620 manual, installation instructions MDE-3801 nut Q12068-04 software (firmware) CRIND® BIOS K93744-01 graphics, right option door 12 12 For components see table “Q13781-01 Cable Group” on page 3. Note: Right Option Door Graphics T50148-G1 are an Order Entry Item. Q13781-01 Cable Group Cable group Q13781-01 for all kits contains the following cables: Cables Part Number Gateway to CRIND logic R20437-G01 Quantity per kit AC power R20580-G2 Light/Multi-protocol Reader, A-Side R20665-G1 Light/Multi-protocol Reader, B-Side R20665-G2 Gateway to Light/MPR/Power Boards R20724-G1 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 3 Parts Lists Kits for Narrow Frame Units, Dual- and Single-Sided Kits C00012-001-NF-D (dual-sided) and C00012-001-NF-S (single-sided) for The Advantage Narrow Frames (36’’) contain the following parts. Description Part Number cable clamp, gray Q13558-04 cable group Q13781-01 cable tie Q10178-02 card cage assembly T20538-G1 door assembly, right options clear with TRIND T20539-G1 Quantity WF-D Kit Quantity NF-S Kit 12 For components see table “Q13781-01 Cable Group” on page 3. graphics, right option door T50148-G1 (see note) (see note) grommet strip, solid Q10315-06 .583 ft. .583 ft. jump jack Q11011-01 10 10 label plate, FCC N23936-01 manual, graphics installation instructions MDE-2620 manual, installation instructions MDE-3801 nut Q12068-04 K93744-01 software (firmware) CRIND® BIOS Note: Right Option Door Graphics T50149-G1 are an Order Entry Item. Page 4 12 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Safety Information Safety Information Alert Symbol and Signal Words Alert Symbol: This is a standard ANSI* approved alert symbol. When you see this symbol, be alert to the potential for a personal injury. * Reference American National Standard Bulletins ANSI Z535. Signal Words: These signal words alert you to important safety hazards. WARNING The hazard or unsafe practice may result in severe injury or death. CAUTION The hazard or unsafe practice could result in minor injury. DANGER The hazard or unsafe practice will result in severe injury or death. Safety Symbols: The following safety symbols are used throughout this manual to alert you to personal safety hazards and precautions. Explosive Flammable Electrical hazard Use safety barricades No people in area No vehicles in area OFF Use emergency power disconnect No open flames No smoking No power tools Wear eye protection Read all related manuals Clean up spills Turn power off MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 5 Safety Information Before Beginning Do the following: WARNING Dangerous Environment! Failure to install this equipment in accordance with NFPA 30A and NFPA 70 could result in severe injury or death. Read, understand and follow NFPA 30A and NFPA 70. Read all instructions before beginning. Follow all safety precautions, including: • Barricade work area. • Do not allow vehicles or unauthorized people in work area. • Do not use power tools in work area. • Do not permit smoking or open flames in work area. • Wear protective gear while performing this installation. Record all mechanical and electronic totals. OFF Turn off all power to unit, unit lights and STPs. • Use system circuit breakers. • Multiple disconnects may be required. • Isolate each pump at distribution box. • Refer to MDE-2531, Pump and Dispenser Start-up and Service for OSHA lock-out/tag-out procedures. WARNING Working on dispenser electronics with power applied may result in electrocution and damage to electronic components. OFF Power down unit before beginning work. When system battery is present, turn off system battery by pressing CLEAR then ENTER on manager keypad. Page 6 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Safety Information Use Electrostatic Discharge Precautions Place yourself at a neutral static-free potential by doing the following: 1 Touch an unpainted metal surface. 2 Use a wrist strap connected to a grounded metal frame or chassis. OFF Note: Failure to use electrostatic discharge precautions may damage electronic components and void warranty. Make sure all power has been removed from unit and CRIND. Follow OSHA Lock-Out and Tag-Out Requirements OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/Tag-Out) covers ways to avoid personal injury if power is turned on or fuel pressure is applied unexpectedly while servicing equipment. The rule requires that equipment power and fuel under pressure be turned off and the device (breaker, valve, etc.) locked or labeled with a warning tag. Read OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/ Tag-Out). Station employees and service contractors need to understand and comply with this program completely to ensure safety while the equipment is down. Tag-Out and Lock-Out Procedure Use plastic warning tags with signature/date blanks for Tag-Out. Sign and date them at shut down. Attach tags with plastic connectors. Use metal screw-down lock clamps or plastic single or multi-pole devices for Lock-Out of breakers and switches. Always use a lock-out device whenever possible. When working on electronics and electrical connections (junction box): • Turn off unit power, light breakers, and all dispensers sharing the same isolation relay box. • Install lock-out device and tag on breaker(s). Note: If station does not use STP control wire isolation relays, multiple disconnects may be required to shut off all power supplied to the unit. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 7 Installation Installation Preparing for Installation 1 Before proceeding read and follow all safety instructions and procedures. 2 Open main access doors. Refer to MDE-2531, Pump and Dispenser Start-Up/Service Manual for access instructions. 3 Disconnect and remove existing hardware according to the following: • For wide frame units disconnect any cables and remove any call or stop buttons, or door alarm switch hardware from existing right options door. Save all removed hardware for reassembly. • For narrow frame units disconnect cables to PPU and main display. 4 Remove door mounting pin and right options door. Pin S0001719 5 If unit has Cash Acceptor, remove door alarm and all hardware from old door and save. 6 Dispose of door. Save pin for reassembly. Page 8 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Installation Modifying Right Options Door On Wide Frame Units For all narrow frame units, or wide frame units without stop or call buttons or door alarm switches, proceed to “Installing Cables” on page 13. For wide or narrow frame units without stop or call units but with door alarm, proceed to “Re-installing Door Alarm Switches” on page 12. For wide frame units with stop or call button previously installed on right options door, do the following to relocate hardware to new TRIND Multi 1 options door. S0001732 1 Remove all hardware from new right options door according to the following steps and save all parts for reassembly. • Remove two screws (1) mounting sheet metal antenna shield (2) on rear of door. Save shield and screws for reassembly. Note: Screw (G) fastening grounding wire on side of sheet metal shield does not need to be removed. • Disconnect cable R20718-G1 from light/microreader printed circuit board T20545-G1 (3) by disconnecting J191 on cable from P191 on board. • Remove two standoff-screws (4) holding light/microreader board (3), and remove board. Save for reassembly. • Remove two screws (5) and carefully pry antenna board T20551-G1 (6) off four standoffs (7) on door and save for reassembly. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 9 Installation 2 Use center punch and hammer to mark placement of pump stop or call button hole on new right options door by measuring from door edges as shown below. S0001734 1 9/16" 3 3/16" 3 Away from fuel island, drill a 7/8 inch diameter hole in location illustrated above. 4 Remove any burrs around hole with deburring tool or rounded file. Page 10 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Installation Re-installing Button 1 Hold contact base on back of door and align with hole drilled earlier. Push button S0001735 Base Contact switch base assembly Contact block 2 Insert push button from front of door by aligning tabs with slots in base. 3 Turn push button 45° clockwise to lock button to base. 4 Tighten two screws on base to secure push button and base assembly to door. Note: Do not overtighten screws. 5 Attach contact block to base with center screw if not already installed. 6 If unit does not have door alarm, reinstall all new right options door hardware except sheet metal shield by reversing procedures in Step 1 of “Modifying Right Options Door On Wide Frame Units” on page 9 and proceed to “Installing Cables” on page 13. If unit has door alarm, proceed to “Re-installing Door Alarm Switches” on page 12. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 11 Installation Re-installing Door Alarm Switches For units with cash acceptors, follow these steps to re-install door alarm assemblies on TRIND™ right option doors. Refer to diagram on this page for more information. Perform each step for both ‘A’ and ‘B’ side right option doors. 1 Remove lock hardware from new right options door. 1 Re-install C-clips removed from old right side option doors on new door. Back view of 36” Unit Option Doors Back view of 48” Unit Option Doors C-clip Right option door Fiber board S0001737 Door alarm assembly bracket Door alarm assembly S0001736 Door alarm door bracket Door alarm assembly Door alarm assembly bracket 2 Install door alarm assembly to door alarm assembly bracket with screw previously removed. 3 Attach door alarm assembly bracket to display board with screw previously removed. Note: Replace the piece of fiberboard between door alarm bracket assembly and display board. 4 Be sure magnet does not touch door alarm door bracket. Slightly move door alarm door bracket away, if necessary. 5 Reinstall all new right options door TRIND hardware except sheet metal cover by reversing procedures in Step 1 of “Modifying Right Options Door On Wide Frame Units” on page 9. Page 12 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Installation Installing Cables Position kit cables according to the following steps: 1 Carefully pry out printer cable retainer from underside of printer shelf. 2 Disconnect printer cable and pull cable out of 2 3/4" round hole from bottom, and install piece of strip grommet Q10315-06/B around perimeter of hole. 2 3/4” printer cable hole and cable retainer 3 Feed three-prong end of power cable R20580-G2, J250 end of R20437-G01 ribbon cable and multiple connector ends of cables R20665-G1 and R20665-G2 up through hole and lay cable ends toward A side. R20580-G2 R20665-G1 and R20665-G2 cables R20437-G01 ribbon cable 4 Reinstall printer cable and retainer disconnected and removed in step 2. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 13 Installation Installing Card Cage Prepare T20538-G1 card cage for installation. Note: For more cable connection detail see “Cable Block Diagrams” on page 24. 1 Locate tab at left front top of card cage. 2 From B side of unit, turning card cage sideways to unit, feed top and rear of card cage up and into shelf. Note: Front of card cage will face B side. 3 Position card cage so that tab fits over latch cutout for main door latch to secure card cage to shelf divider. Note position of two screws protruding from bottom of card cage: • For newer units, both screws will pass through holes in printer shelf. • For older units, holes will not align with holes in shelf. Remove both screws and save. 4 Position rear of card cage on edge of cabinet shelf for easy cable connection. Note: Do not secure card cage at this time. Connecting cables and setting jump jacks are easier if card cage can be manipulated by installer. Connect R20580-G2 power cable Rear side of card cage shown J8 on DCB for P8 on R20665-G2 for B side J7 on DCB for P7 on R02665-G1 for A side RS232 Port 5 Connect three prong female end of power cable R20580-G2 to card cage at location shown. 6 Connect P7 on R20665-G1 to J7 and P8 on R20665-G2 to J8 on DCB at location shown. 7 Connect J186 on R20724-G1 cable to P186 on Gateway Board on top of card cage. Gateway board on top of card cage Page 14 For J186 on R20724-G1 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Installation Address Gateway Board Before Installing Card Cage Address for TRIND™ must match address on CRIND® logic board. Follow these steps: 1 From A side of unit lower CRIND tray. Refer to MDE-2562 CRIND Service Manual. 2 Locate jump jacks on A and B side CRIND logic boards T17764-XX. 3 Note position of jump jacks and set jump jacks on Gateway board T20128 to match address on CRIND logic boards for both A and B sides. MOC and Generic CRIND Addresses. Address On CRIND Logic Board T17764-XX JP8 JP7 JP6 JP5 JP4 = Address on Gateway Board T20128 ‘A’ Side JP6 JP7 JP8 JP9 JP10 = Address on Gateway Board T20128 ‘B’ Side JP14 JP15 JP16 JP17 JP18 Jump jack locations on Gateway Board MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 IN OUT OUT OUT OUT OUT IN OUT OUT OUT IN IN OUT OUT OUT OUT OUT IN OUT OUT IN OUT IN OUT OUT OUT IN IN OUT OUT IN IN IN OUT OUT OUT OUT OUT IN OUT IN OUT OUT IN OUT 10 OUT IN OUT IN OUT 11 IN IN OUT IN OUT 12 OUT OUT IN IN OUT 13 IN OUT IN IN OUT 14 OUT IN IN IN OUT 15 IN IN IN IN OUT 16 OUT OUT OUT OUT IN 17 IN OUT OUT OUT IN 18 OUT IN OUT OUT IN 19 IN IN OUT OUT IN 20 OUT OUT IN OUT IN 21 IN OUT IN OUT IN 22 OUT IN IN OUT IN 23 IN IN IN OUT IN 24 OUT OUT OUT IN IN 25 IN OUT OUT IN IN 26 OUT IN OUT IN IN 27 IN IN OUT IN IN 28 OUT OUT IN IN IN 29 IN OUT IN IN IN 30 OUT IN IN IN IN 31 IN IN IN IN IN 32 OUT OUT OUT OUT OUT Page 15 Installation Install card cage assembly. Install card cage by doing the following: Tab on card cage clinch nut card cage front facing B side Note: While it is not necessary to remove printer to install card cage you may find your initial installations easier if this is done. To do so, disconnect two cables and remove ground connector to A side printer. Remove printer and printer mounting hardware from unit and save for reinstallation. 1 Locate tab at left front top of card cage. 2 From B side, turn card cage sideways to unit, feed top and rear of card cage up and into shelf. Note: Front of card cage will face B side. 3 Position card cage so that tab fits over latch cutout for main door latch, securing card cage to shelf divider. • If two screws on card cage pass through shelf secure from underside of shelf with two nuts provided in kit. • If screws were removed, secure card cage from underside of shelf by installing one screw removed in section “Prepare T20538-G1 card cage for installation.” on page 14 up through hole in shelf to clinch nut on card cage (see illustration above). Dispose of second screw and two nuts. Tab locks into shelf divided at latch cut-out Page 16 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Installation Installing Right Option Door Mount New Right Options Door Install new right options door according to the following steps. 1 If sheet metal shield has not been previously removed, using 1/4’’ nut driver, remove sheet metal shield from back of door. Refer to illustration in “Modifying Right Options Door On Wide Frame Units” on page 9 for detail. Save cover and hardware. 2 Remove key taped to inside of new right options door and save. 3 Position new right options door and install with pin removed with old door and saved. Note: If unit had stop or call button transferred from old door to new TRIND door, reconnect stop or call button wires to contact block. Route cables to Right Option Doors Note: Cable R20665-G1 to A side is shorter than B side cable R20665-G2 Cable clamp inside door Cable clamps provided with kit R20665-XX cable 1 Route A side cable R20665-G1 through cable clamp inside door and secure along door with clamps provided with kit. 2 Route B side cable through clamps above CRIND tray to cable clamp inside door, and secure along door with clamps provided with kit. Note: When routing from cabinet to main door, allow sufficient slack in cables to allow main door to open and close without pulling or crimping cables. Also check that cable is not crimped when door is closed. 3 Route cables around board as shown for both wide and narrow frame units, securing cable to board with tie-wrap. tie-wrap J182 4 Connect J182 on each cable to P182 on PCB assembly on option door. 5 Reinstall sheet metal cover on door, being careful to avoid crimping cables. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 17 Installation Connecting Remaining Cables 1 From A side, pass J250 end of cable R20437-G01, J176 and JA ends of cable R20665-G1 and J177 and PA ends of cable R20665-G2 through card cage to B side. P186 P250 on Gateway Board pass cables through cage P176 P177 JA and PA connectors on R20724-G1 2 From B side, connect J176 on cable R20665-G1 to P176 on Power Supply PCB. Note: Detailed information provided on “Cable Block Diagrams” on page 24. 3 Connect J177 on cable R20665-G2 to P177. 4 Connect JA on R20665-G1 to PA on R20724-G1 cable. 5 Connect PA on R20665-G2 cable to JA on R20724-G1 cable. 6 Connect J250 on ribbon cable R20437-G01 to P250 on Gateway board on top of card cage. From A side of unit make the following connections: 1 On ribbon cable R20437-G01, connect J258A to P258 on A side CRIND Logic Board. Note: A side of split cable R20437-G01 has red wire. 2 On ribbon cable R20437-G01, connect J258B to P258 on B side CRIND Logic Board. Connect R20580-G2 power cable according to the following: Note: Connections are unit specific. Use appropriate connectors to intercept power by installing R20590-G1 inline. Page 18 For units with: Do the following: System cable W02468 Install inline using 15 pin P601 and J601 connectors System cable T19612 Install inline using 3 pin connectors J601/J708 and P601/P708 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 CRIND® BIOS TRIND™ Multi 1 Upgrade CRIND® BIOS TRIND™ Multi 1 Upgrade Units must have current Z-180 CRIND logic board. Install the CRIND Bios TRIND software K93744-01, one per logic board, on the T17764-XX CRIND logic board(s) according to the following steps. Note: A properly grounded electrostatic discharge wrist strap must be worn during this procedure. T17764-XX CRIND logic board (-G3 shown) Chip orientation notch U7 JP1-16 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 19 CRIND® BIOS TRIND™ Multi 1 Upgrade 1 Locate and remove existing BIOS at U7 on CRIND® logic board T17764-XX using a grounded chip removal tool. Grounding strap Chip removal tool 2 Install TRIND BIOS K93744-01 (one per logic board) at position U7, orienting notch on chip with indication mark on board as shown. 3 Install jump jack on JP-16 for each side of unit. Note: Jumper on JP-16 informs the CRIND that a TRIND system is present. 4 Restore CRIND tray to operating position. Page 20 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Dispenser Set-Up Dispenser Set-Up Addressing Dispenser Each dispenser on the G-Site controller must be addressed differently; no two dispensers may have the same address. Address is at discretion of the installer. Follow these steps: 1 From A side of unit, locate dip switches on power supply board (PCB) T20314-G1 in card cage. 2 Using switches 2, 3, 4 and 5 address each dispenser according to the following table: Note: Switch one in down position is standalone mode selected, used for service only. Switch Numbers = Value 1 = Standalone Mode 2=1 3=2 4=4 5=8 Dip switch down Dip switch up Setting Baud Rate For major oil company (MOC) TRIND™ installations there is no requirement to set or change baud rate. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 21 Dispenser Set-Up Testing TRIND™ Multi 1 1 If printer was removed, replace printer and reconnect two cables and ground. 2 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531. 3 Restoring power with new Bios will Cold Start the CRIND. Refer to CRIND Service Manual MDE-2562. Note: Cold Start is required if TRIND equipment is installed or changed. 4 Present test tag at option door from a distance of 6’’ or less. Light board should light and flash sequentially and emit one beep. Screen prompt should appear as shown. Note: If light does not function properly, check to see if opposite side of unit was activated, indicating a crossed cable. 5 When using test tag, screen will show “Test Confirmed”. In regular operation, screen will display the following. Page 22 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Dispenser Set-Up Completing Installation 1 Close and secure option and maindoor. 2 Install graphics. Refer to MDE-2620 Graphics Installation for The Advantage Series. 3 Peel backing paper off FCC label pate provided in kit. 4 Affix FCC label plate to inside frame sheathing on column under existing FCC label. 5 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531. MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 Page 23 Page 24 S0001730 J181 P191 J191 J812 ANTENNA HAND HELD T20551 G1 U812 AC FUSE Q10131 02 16 P181 "A" SIDE INDICATOR LIGHT BOARD Q13786 01 LIGHT/MICROREADER P.C.B. ASSEMBLY T20545 G1 R20720 TO CRIND LOGIC SEE (T19503) P182 J182 10 R20718 G1 R20665 G1 R20524 G3 J258B J258A JA 1 1 R20543 G3 1 1 E1 P4 J4 J8 J6 P187 J250 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 R20437 G01 P250 14 10 10 P173 P176 J185 P185 PA P8 J176 J179 P179 INDEX SH SHEET P188 NEXT ASSY T20538 P251A P7 PA APPLICATION USED ON TRIND MULTI_1 JA R20724 G1 J186 J7 J177 AC PWR R20524 G2 J175 P177 P186 10 P3 R20580 G1 P178 P175 TI GATEWAY P.C.B. ASSEMBLY T20128 G2 A B REV J187 R20525 G1 J5 DATA CONTROL BOARD Q13563 03 J2 P3 J3 POWER SUPPLY P.C.B. ASSEMBLY T20314 G1 P174 J174 TI/RFID TRANSFORMER SUBASSY R20719 G1 R20206 G11 P601/ P708 J601/ J708 10 P182 DECIMALS: 2 PLACE ± 3 PLACE ± ANGLES:± FRACTIONS:± UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES. TOLERANCES ON CGILBARCO INC. UNPUBLISHED THIS PRINT IS THE PROPERTY OF GILBARCO INC., N.C., U.S.A. INFORMATION HEREON IS CONFIDENTIAL AND MUST NOT BE REPRODUCED OR RELEASED OUTSIDE GILBARCO WITHOUT PROPER AUTHORIZATION. GILBARCO CONFIDENTIAL J182 P601 J601 R20718 G1 MATERIAL FINAL PROTECTIVE FINISH "B" SIDE INDICATOR LIGHT BOARD Q13786 01 P181 16 GREENSBORO, N.C. 64301-0 APP SYM NO. 1 OF 2 R20720 SH NO. SCALE NONE EAN: WMH 09/10/99 64489-0 EAN: JTB 08/26/99 64455-0 REVISED SH INDEX. ADDED: R20543 G3 & R20206 G11. RMV: Q10895 01 FILTER; R20206 G9; R20543 G1; AND R20543 G2. REVISED SH INDEX CHNG: R20206 G10 WAS G9. RMV: CONNECTION E2; DASHES FROM ALL PART NUMBERS. DESCRIPTION REVISIONS DIAGRAM, TRIND MULTI_1, BLOCK SYM WMH 07/13/99 TR EAN NO. CK DR J181 LIGHT/MICROREADER P.C.B. ASSEMBLY T20545 G1 P191 J191 J812 ANTENNA HAND HELD T20551 G1 U812 TO J601 SYSTEM CABLE W02468 15 15 TO P601 MAIN POWER SUPPLY ASSY R20665 G2 TO J601/J708 SYSTEM CABLE T19612 TO P601/P708 MAIN POWER SUPPLY ASSY Cable Block Diagrams Cable Block Diagrams 3 REVISIONS R20720 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99 SYM DESCRIPTION RMV: DASHES FROM ALL PART NUMBERS JTB EAN: 08/26/99 64455-0 J802C BACKLITE LCD DISPLAY ASSEMBLY T20262 REFLECTOR ASSY 0.6 INCH T17622 G9 P802 J802B J802A 20 REFLECTOR ASSY 0.6 INCH T17622 G9 P802 REFLECTOR ASSY 0.6 INCH T17622 G9 P802 P804 P801 J804 J801 34 P/O W03715 G2 P/O T19793 G3 NARROW FRAME DOOR ONLY CGILBARCO INC. UNPUBLISHED THIS PRINT IS THE PROPERTY OF GILBARCO INC., N.C., U.S.A. INFORMATION HEREON IS CONFIDENTIAL AND MUST NOT BE REPRODUCED OR FINAL PROTECTIVE FINISH DIAGRAM, TRIND MULTI_1, BLOCK RELEASED OUTSIDE GILBARCO WITHOUT PROPER AUTHORIZATION. T20538 Page 25 NEXT ASSY S0001731 TRIND MULTI_1 USED ON APPLICATION UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES. TOLERANCES ON DECIMALS: 2 PLACE ± 3 PLACE ± FRACTIONS:± GREENSBORO, N.C. MATERIAL DR WMH 07/13/99 CK EAN NO. 64301-0 ANGLES:± TR SCALE APP SH NO. SYM NO. NONE R20720 Cable Block Diagrams GILBARCO CONFIDENTIAL Cable Block Diagrams © 1999 Gilbarco, Inc. • 7300 West Friendly Avenue • Post Office Box 22087 • Greensboro, North Carolina 27420 • Phone (336) 547-5000 • http://www.gilbarco.com MDE- 3801 10/99 Printed in the U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Page Count : 26 Page Mode : UseOutlines Create Date : 1999:10:01 15:47:20 Producer : Acrobat Distiller 3.01 for Windows Title : Untitled Document Creator : FrameMaker 5.5.6p145EXIF Metadata provided by EXIF.tools