Gilbarco GBIRA Radio Frequency Identification Device User Manual

Gilbarco Inc. Radio Frequency Identification Device

installation instructions

Download: Gilbarco GBIRA Radio Frequency Identification Device User Manual
Mirror Download [FCC.gov]Gilbarco GBIRA Radio Frequency Identification Device User Manual
Document ID62763
Application IDL4H6EKjYf8HmFpMEEsMZag==
Document Descriptioninstallation instructions
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize44.42kB (555199 bits)
Date Submitted1999-10-08 00:00:00
Date Available2000-01-19 00:00:00
Creation Date1999-10-01 15:47:20
Producing SoftwareAcrobat Distiller 3.01 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleUntitled Document
Document CreatorFrameMaker 5.5.6p145

MDE-3801
TRIND™ MULTI 1
Transmitter/Receiver in Dispenser
Retrofit Kits C00012-001-XX
Installation
Introduction
Purpose of this Manual
This manual provides instruction for installing TRIND™ Multi 1 Retrofit Kits in The
Advantage® Series wide frame and narrow frame units with InfoScreen®, monochrome
CRIND®, or single-line CRIND.
The TRIND option allows customers to automatically authorize CRIND-equipped units using
a hand-held transponder tag provided by a major oil company (MOC). Use this kit for one- or
two-sided units.
Prerequisites
Before installing the TRIND kit, ensure that the existing CRIND has the Z-180 logic board
T17764-XX, which is not provided in TRIND retrofit kit.
Important Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy, and if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense. Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate this equipment.
Required Reading
Before installing the equipment, the installer must read, understand, and follow:
• this manual
• NFPA 30A, The Automotive and Marine Service Station Code
• NFPA 70, The National Electric Code
• applicable federal, state and local codes and regulations
Failure to do so may adversely effect the safe use and operation of the equipment.
Note: This kit must be installed by a Gilbarco ASC (Authorized Service Contractor) to insure
warranty.
Related Documents
MDE-2531
MDE-2562
MDE-2628
MDE-2620
PT-1728
PT-1736
Pump & Dispenser Start-Up & Service Manual
CRIND Service Manual
Cash Acceptor Retrofit Assemblies for The Advantage Series with CRIND
Graphics Panel Application for The Advantage Series
The Advantage Series Illustrated Parts Manual
CRIND Card Reader Illustrated Parts Manual
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 1
Introduction
Required Tools
The following equipment is needed to install all TRIND™ Multi 1 kits
• Allen wrench set, American standard
• clean cloth or rag
• chip extraction tool, e.g., IC extraction, Digikey Part No. K158-ND or equivalent
• isopropyl alcohol (part# END-1082)
• needle nose pliers
• nut driver, 1/4'', 3/8''
• pocket knife
• Q12534 CRIND diagnostic card
• ratchet set, standard
• screwdrivers, flat and Phillips head
• static guard wrist strap
The following additional tools are required if kit is to be installed on wide frame
units with call or stop button on existing right options door.
• center punch
• deburring tool or round file
• hand drill, battery electric or pneumatic
• light hammer
• pilot drill bit (between 3/32” and 1/4”) and 7/8” drill bit
• standard tape measure or rule
Page 2
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Parts Lists
Parts Lists
Kits for Wide Frame Units, Dual- and Single-Sided
Kits C00012-001-WF-D (dual-sided) and C00012-001-WF-S (single-sided) for The
Advantage Wide Frames (48’’) contain the following parts.
Description
Part Number
Quantity WF-D Kit Quantity WF-S Kit
cable clamp, gray
Q13558-04
cable group
Q13781-01
cable tie
Q10178-02
card cage assembly
T20538-G1
door assembly, right options clear with TRIND T20537-G1
T50148-G1
(see note)
(see note)
grommet strip, solid
Q10315-06
.583 ft.
.583 ft.
jump jack
Q11011-01
10
10
label plate, FCC
N23936-01
manual, graphics installation instructions
MDE-2620
manual, installation instructions
MDE-3801
nut
Q12068-04
software (firmware) CRIND® BIOS
K93744-01
graphics, right option door
12
12
For components see table “Q13781-01
Cable Group” on page 3.
Note: Right Option Door Graphics T50148-G1 are an Order Entry Item.
Q13781-01 Cable Group
Cable group Q13781-01 for all kits contains the following cables:
Cables
Part Number
Gateway to CRIND logic
R20437-G01
Quantity per kit
AC power
R20580-G2
Light/Multi-protocol Reader, A-Side
R20665-G1
Light/Multi-protocol Reader, B-Side
R20665-G2
Gateway to Light/MPR/Power Boards
R20724-G1
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 3
Parts Lists
Kits for Narrow Frame Units, Dual- and Single-Sided
Kits C00012-001-NF-D (dual-sided) and C00012-001-NF-S (single-sided) for The
Advantage Narrow Frames (36’’) contain the following parts.
Description
Part Number
cable clamp, gray
Q13558-04
cable group
Q13781-01
cable tie
Q10178-02
card cage assembly
T20538-G1
door assembly, right options clear with TRIND T20539-G1
Quantity WF-D Kit Quantity NF-S Kit
12
For components see table “Q13781-01
Cable Group” on page 3.
graphics, right option door
T50148-G1
(see note)
(see note)
grommet strip, solid
Q10315-06
.583 ft.
.583 ft.
jump jack
Q11011-01
10
10
label plate, FCC
N23936-01
manual, graphics installation instructions
MDE-2620
manual, installation instructions
MDE-3801
nut
Q12068-04
K93744-01
software (firmware)
CRIND®
BIOS
Note: Right Option Door Graphics T50149-G1 are an Order Entry Item.
Page 4
12
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Safety Information
Safety Information
Alert Symbol and Signal Words
Alert Symbol:
This is a standard ANSI* approved alert symbol. When you see this symbol, be alert to the
potential for a personal injury.
* Reference American National Standard Bulletins ANSI Z535.
Signal Words:
These signal words alert you to important safety hazards.
WARNING
The hazard or unsafe
practice may result in
severe injury or death.
CAUTION
The hazard or unsafe
practice could result in
minor injury.
DANGER
The hazard or unsafe
practice will result in
severe injury or death.
Safety Symbols:
The following safety symbols are used throughout this manual to alert you to personal safety
hazards and precautions.
Explosive
Flammable
Electrical hazard
Use safety barricades
No people in area
No vehicles in area
OFF
Use emergency power disconnect
No open flames
No smoking
No power tools
Wear eye protection
Read all related manuals
Clean up spills
Turn power off
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 5
Safety Information
Before Beginning
Do the following:
WARNING
Dangerous Environment! Failure to
install this equipment in accordance
with NFPA 30A and NFPA 70 could
result in severe injury or death.
Read, understand and follow NFPA
30A and NFPA 70.
Read all instructions before beginning.
Follow all safety precautions, including:
• Barricade work area.
• Do not allow vehicles or unauthorized people in work area.
• Do not use power tools in work area.
• Do not permit smoking or open flames in work area.
• Wear protective gear while performing this installation.
Record all mechanical and electronic totals.
OFF
Turn off all power to unit, unit lights and STPs.
• Use system circuit breakers.
• Multiple disconnects may be required.
• Isolate each pump at distribution box.
• Refer to MDE-2531, Pump and Dispenser Start-up and Service for OSHA
lock-out/tag-out procedures.
WARNING
Working on dispenser
electronics with power
applied may result in
electrocution and
damage to electronic
components.
OFF
Power down unit before
beginning work.
When system battery is present, turn off system battery by pressing CLEAR then ENTER on
manager keypad.
Page 6
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Safety Information
Use Electrostatic Discharge Precautions
Place yourself at a neutral static-free potential by doing the following:
1 Touch an unpainted metal surface.
2 Use a wrist strap connected to a grounded metal frame or chassis.
OFF
Note: Failure to use electrostatic discharge precautions may damage electronic components
and void warranty.
Make sure all power has been removed from unit and CRIND.
Follow OSHA Lock-Out and Tag-Out Requirements
OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/Tag-Out)
covers ways to avoid personal injury if power is turned on or fuel pressure is applied
unexpectedly while servicing equipment. The rule requires that equipment power and fuel
under pressure be turned off and the device (breaker, valve, etc.) locked or labeled with a
warning tag.
Read OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/
Tag-Out). Station employees and service contractors need to understand and comply with this
program completely to ensure safety while the equipment is down.
Tag-Out and Lock-Out Procedure
Use plastic warning tags with signature/date blanks for Tag-Out. Sign and date them at shut
down. Attach tags with plastic connectors.
Use metal screw-down lock clamps or plastic single or multi-pole devices for Lock-Out of
breakers and switches. Always use a lock-out device whenever possible.
When working on electronics and electrical connections (junction box):
• Turn off unit power, light breakers, and all dispensers sharing the same isolation relay
box.
• Install lock-out device and tag on breaker(s).
Note: If station does not use STP control wire isolation relays, multiple disconnects may be
required to shut off all power supplied to the unit.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 7
Installation
Installation
Preparing for Installation
1 Before proceeding read and follow all safety instructions and procedures.
2 Open main access doors. Refer to MDE-2531, Pump and Dispenser Start-Up/Service Manual
for access instructions.
3 Disconnect and remove existing hardware according to the following:
• For wide frame units disconnect any cables and remove any call or stop buttons, or door
alarm switch hardware from existing right options door. Save all removed hardware for
reassembly.
• For narrow frame units disconnect cables to PPU and main display.
4 Remove door mounting pin and right options door.
Pin
S0001719
5 If unit has Cash Acceptor, remove door alarm and all hardware from old door and save.
6 Dispose of door. Save pin for reassembly.
Page 8
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Installation
Modifying Right Options Door On Wide Frame Units
For all narrow frame units, or wide frame units without stop or call buttons or door alarm
switches, proceed to “Installing Cables” on page 13. For wide or narrow frame units without
stop or call units but with door alarm, proceed to “Re-installing Door Alarm Switches” on
page 12. For wide frame units with stop or call button previously installed on right options
door, do the following to relocate hardware to new TRIND Multi 1 options door.
S0001732
1 Remove all hardware from new right options door according to the following steps and save
all parts for reassembly.
• Remove two screws (1) mounting sheet metal antenna shield (2) on rear of door. Save
shield and screws for reassembly.
Note: Screw (G) fastening grounding wire on side of sheet metal shield does not need to be
removed.
• Disconnect cable R20718-G1 from light/microreader printed circuit board T20545-G1 (3)
by disconnecting J191 on cable from P191 on board.
• Remove two standoff-screws (4) holding light/microreader board (3), and remove board.
Save for reassembly.
• Remove two screws (5) and carefully pry antenna board T20551-G1 (6) off four standoffs
(7) on door and save for reassembly.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 9
Installation
2 Use center punch and hammer to mark placement of pump stop or call button hole on new right
options door by measuring from door edges as shown below.
S0001734
1 9/16"
3 3/16"
3 Away from fuel island, drill a 7/8 inch diameter hole in location illustrated above.
4 Remove any burrs around hole with deburring tool or rounded file.
Page 10
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Installation
Re-installing Button
1 Hold contact base on back of door and align with hole drilled earlier.
Push button
S0001735
Base
Contact switch
base assembly
Contact
block
2 Insert push button from front of door by aligning tabs with slots in base.
3 Turn push button 45° clockwise to lock button to base.
4 Tighten two screws on base to secure push button and base assembly to door.
Note: Do not overtighten screws.
5 Attach contact block to base with center screw if not already installed.
6 If unit does not have door alarm, reinstall all new right options door hardware except sheet
metal shield by reversing procedures in Step 1 of “Modifying Right Options Door On Wide
Frame Units” on page 9 and proceed to “Installing Cables” on page 13. If unit has door alarm,
proceed to “Re-installing Door Alarm Switches” on page 12.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 11
Installation
Re-installing Door Alarm Switches
For units with cash acceptors, follow these steps to re-install door alarm assemblies on
TRIND™ right option doors. Refer to diagram on this page for more information. Perform
each step for both ‘A’ and ‘B’ side right option doors.
1 Remove lock hardware from new right options door.
1 Re-install C-clips removed from old right side option doors on new door.
Back view of 36” Unit Option Doors
Back view of 48” Unit Option Doors
C-clip
Right option door
Fiber board
S0001737
Door alarm
assembly bracket
Door alarm assembly
S0001736
Door alarm door bracket
Door alarm assembly
Door alarm assembly bracket
2 Install door alarm assembly to door alarm assembly bracket with screw previously removed.
3 Attach door alarm assembly bracket to display board with screw previously removed.
Note: Replace the piece of fiberboard between door alarm bracket assembly and display board.
4 Be sure magnet does not touch door alarm door bracket. Slightly move door alarm door
bracket away, if necessary.
5 Reinstall all new right options door TRIND hardware except sheet metal cover by reversing
procedures in Step 1 of “Modifying Right Options Door On Wide Frame Units” on page 9.
Page 12
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Installation
Installing Cables
Position kit cables according to the following steps:
1 Carefully pry out printer cable retainer from underside of printer shelf.
2 Disconnect printer cable and pull cable out of 2 3/4" round hole from bottom, and install piece
of strip grommet Q10315-06/B around perimeter of hole.
2 3/4” printer
cable hole
and cable
retainer
3 Feed three-prong end of power cable R20580-G2, J250 end of R20437-G01 ribbon cable and
multiple connector ends of cables R20665-G1 and R20665-G2 up through hole and lay cable
ends toward A side.
R20580-G2
R20665-G1 and
R20665-G2 cables
R20437-G01
ribbon cable
4 Reinstall printer cable and retainer disconnected and removed in step 2.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 13
Installation
Installing Card Cage
Prepare T20538-G1 card cage for installation.
Note: For more cable connection detail see “Cable Block Diagrams” on page 24.
1 Locate tab at left front top of card cage.
2 From B side of unit, turning card cage sideways to unit, feed top and rear of card cage up and
into shelf.
Note: Front of card cage will face B side.
3 Position card cage so that tab fits over latch cutout for main door latch to secure card cage to
shelf divider. Note position of two screws protruding from bottom of card cage:
• For newer units, both screws will pass through holes in printer shelf.
• For older units, holes will not align with holes in shelf. Remove both screws and save.
4 Position rear of card cage on edge of cabinet shelf for easy cable connection.
Note: Do not secure card cage at this time. Connecting cables and setting jump jacks are
easier if card cage can be manipulated by installer.
Connect
R20580-G2
power cable
Rear side of card
cage shown
J8 on DCB for
P8 on
R20665-G2 for
B side
J7 on DCB for
P7 on
R02665-G1 for
A side
RS232 Port
5 Connect three prong female end of power cable R20580-G2 to card cage at location shown.
6 Connect P7 on R20665-G1 to J7 and P8 on R20665-G2 to J8 on DCB at location shown.
7 Connect J186 on R20724-G1 cable to P186 on Gateway Board on top of card cage.
Gateway
board on
top of
card
cage
Page 14
For J186 on
R20724-G1
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Installation
Address Gateway Board Before Installing Card Cage
Address for TRIND™ must match address on CRIND® logic board. Follow these steps:
1 From A side of unit lower CRIND tray. Refer to MDE-2562 CRIND Service Manual.
2 Locate jump jacks on A and B side CRIND logic boards T17764-XX.
3 Note position of jump jacks and set jump jacks on Gateway board T20128 to match address on
CRIND logic boards for both A and B sides.
MOC and Generic CRIND Addresses.
Address On CRIND Logic Board T17764-XX
JP8
JP7
JP6
JP5
JP4
= Address on Gateway Board T20128 ‘A’ Side
JP6
JP7
JP8
JP9
JP10
= Address on Gateway Board T20128 ‘B’ Side
JP14 JP15 JP16 JP17 JP18
Jump jack locations on Gateway Board
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
IN
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
OUT
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
IN
OUT
OUT
IN
OUT
10
OUT
IN
OUT
IN
OUT
11
IN
IN
OUT
IN
OUT
12
OUT
OUT
IN
IN
OUT
13
IN
OUT
IN
IN
OUT
14
OUT
IN
IN
IN
OUT
15
IN
IN
IN
IN
OUT
16
OUT
OUT
OUT
OUT
IN
17
IN
OUT
OUT
OUT
IN
18
OUT
IN
OUT
OUT
IN
19
IN
IN
OUT
OUT
IN
20
OUT
OUT
IN
OUT
IN
21
IN
OUT
IN
OUT
IN
22
OUT
IN
IN
OUT
IN
23
IN
IN
IN
OUT
IN
24
OUT
OUT
OUT
IN
IN
25
IN
OUT
OUT
IN
IN
26
OUT
IN
OUT
IN
IN
27
IN
IN
OUT
IN
IN
28
OUT
OUT
IN
IN
IN
29
IN
OUT
IN
IN
IN
30
OUT
IN
IN
IN
IN
31
IN
IN
IN
IN
IN
32
OUT
OUT
OUT
OUT
OUT
Page 15
Installation
Install card cage assembly.
Install card cage by doing the following:
Tab on
card cage
clinch nut
card cage front facing B side
Note: While it is not necessary to remove printer to install card cage you may find your initial
installations easier if this is done. To do so, disconnect two cables and remove ground
connector to A side printer. Remove printer and printer mounting hardware from unit
and save for reinstallation.
1 Locate tab at left front top of card cage.
2 From B side, turn card cage sideways to unit, feed top and rear of card cage up and into shelf.
Note: Front of card cage will face B side.
3 Position card cage so that tab fits over latch cutout for main door latch, securing card cage to
shelf divider.
• If two screws on card cage pass through shelf secure from underside of shelf with two nuts
provided in kit.
• If screws were removed, secure card cage from underside of shelf by installing one screw
removed in section “Prepare T20538-G1 card cage for installation.” on page 14 up
through hole in shelf to clinch nut on card cage (see illustration above). Dispose of second
screw and two nuts.
Tab locks into shelf divided at latch cut-out
Page 16
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Installation
Installing Right Option Door
Mount New Right Options Door
Install new right options door according to the following steps.
1 If sheet metal shield has not been previously removed, using 1/4’’ nut driver, remove sheet
metal shield from back of door. Refer to illustration in “Modifying Right Options Door On
Wide Frame Units” on page 9 for detail. Save cover and hardware.
2 Remove key taped to inside of new right options door and save.
3 Position new right options door and install with pin removed with old door and saved.
Note: If unit had stop or call button transferred from old door to new TRIND door, reconnect
stop or call button wires to contact block.
Route cables to Right Option Doors
Note: Cable R20665-G1 to A side is shorter than B side cable R20665-G2
Cable clamp inside door
Cable clamps provided with kit
R20665-XX cable
1 Route A side cable R20665-G1 through cable clamp inside door and secure along door with
clamps provided with kit.
2 Route B side cable through clamps above CRIND tray to cable clamp inside door, and secure
along door with clamps provided with kit.
Note: When routing from cabinet to main door, allow sufficient slack in cables to allow main
door to open and close without pulling or crimping cables. Also check that cable is not
crimped when door is closed.
3 Route cables around board as shown for both wide and narrow frame units, securing cable to
board with tie-wrap.
tie-wrap
J182
4 Connect J182 on each cable to P182 on PCB assembly on option door.
5 Reinstall sheet metal cover on door, being careful to avoid crimping cables.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 17
Installation
Connecting Remaining Cables
1 From A side, pass J250 end of cable R20437-G01, J176 and JA ends of cable R20665-G1 and
J177 and PA ends of cable R20665-G2 through card cage to B side.
P186
P250 on
Gateway Board
pass cables
through cage
P176
P177
JA and PA connectors on R20724-G1
2 From B side, connect J176 on cable R20665-G1 to P176 on Power Supply PCB.
Note: Detailed information provided on “Cable Block Diagrams” on page 24.
3 Connect J177 on cable R20665-G2 to P177.
4 Connect JA on R20665-G1 to PA on R20724-G1 cable.
5 Connect PA on R20665-G2 cable to JA on R20724-G1 cable.
6 Connect J250 on ribbon cable R20437-G01 to P250 on Gateway board on top of card cage.
From A side of unit make the following connections:
1 On ribbon cable R20437-G01, connect J258A to P258 on A side CRIND Logic Board.
Note: A side of split cable R20437-G01 has red wire.
2 On ribbon cable R20437-G01, connect J258B to P258 on B side CRIND Logic Board.
Connect R20580-G2 power cable according to the following:
Note: Connections are unit specific. Use appropriate connectors to intercept power by
installing R20590-G1 inline.
Page 18
For units with:
Do the following:
System cable W02468
Install inline using 15 pin P601 and J601 connectors
System cable T19612
Install inline using 3 pin connectors J601/J708 and P601/P708
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
CRIND® BIOS TRIND™ Multi 1 Upgrade
CRIND® BIOS TRIND™ Multi 1 Upgrade
Units must have current Z-180 CRIND logic board.
Install the CRIND Bios TRIND software K93744-01, one per logic board, on the T17764-XX
CRIND logic board(s) according to the following steps.
Note: A properly grounded electrostatic discharge wrist strap must be worn during this
procedure.
T17764-XX
CRIND
logic board
(-G3 shown)
Chip
orientation
notch
U7
JP1-16
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 19
CRIND® BIOS TRIND™ Multi 1 Upgrade
1 Locate and remove existing BIOS at U7 on CRIND® logic board T17764-XX using a
grounded chip removal tool.
Grounding strap
Chip
removal
tool
2 Install TRIND BIOS K93744-01 (one per logic board) at position U7, orienting notch on chip
with indication mark on board as shown.
3 Install jump jack on JP-16 for each side of unit.
Note: Jumper on JP-16 informs the CRIND that a TRIND system is present.
4 Restore CRIND tray to operating position.
Page 20
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Dispenser Set-Up
Dispenser Set-Up
Addressing Dispenser
Each dispenser on the G-Site controller must be addressed differently; no two dispensers may
have the same address. Address is at discretion of the installer. Follow these steps:
1 From A side of unit, locate dip switches on power supply board (PCB) T20314-G1 in card
cage.
2 Using switches 2, 3, 4 and 5 address each dispenser according to the following table:
Note: Switch one in down position is standalone mode selected, used for service only.
Switch Numbers = Value
1 = Standalone Mode
2=1
3=2
4=4
5=8
Dip switch down
Dip switch up
Setting Baud Rate
For major oil company (MOC) TRIND™ installations there is no requirement to set or change
baud rate.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 21
Dispenser Set-Up
Testing TRIND™ Multi 1
1 If printer was removed, replace printer and reconnect two cables and ground.
2 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531.
3 Restoring power with new Bios will Cold Start the CRIND. Refer to CRIND Service Manual
MDE-2562.
Note: Cold Start is required if TRIND equipment is installed or changed.
4 Present test tag at option door from a distance of 6’’ or less. Light board should light and flash
sequentially and emit one beep. Screen prompt should appear as shown.
Note: If light does not function properly, check to see if opposite side of unit was activated,
indicating a crossed cable.
5 When using test tag, screen will show “Test Confirmed”. In regular operation, screen will
display the following.
Page 22
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Dispenser Set-Up
Completing Installation
1 Close and secure option and maindoor.
2 Install graphics. Refer to MDE-2620 Graphics Installation for The Advantage Series.
3 Peel backing paper off FCC label pate provided in kit.
4 Affix FCC label plate to inside frame sheathing on column under existing FCC label.
5 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531.
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Page 23
Page 24
S0001730
J181
P191
J191
J812
ANTENNA
HAND HELD
T20551 G1
U812
AC FUSE
Q10131 02
16
P181
"A" SIDE
INDICATOR
LIGHT BOARD
Q13786 01
LIGHT/MICROREADER
P.C.B. ASSEMBLY
T20545 G1
R20720
TO CRIND LOGIC
SEE (T19503)
P182 J182
10
R20718 G1
R20665 G1
R20524 G3
J258B
J258A
JA
1 1
R20543 G3
1 1
E1
P4
J4
J8
J6
P187
J250
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
R20437 G01
P250
14
10
10
P173
P176
J185 P185
PA
P8
J176
J179
P179
INDEX
SH
SHEET
P188
NEXT ASSY
T20538
P251A
P7
PA
APPLICATION
USED ON
TRIND MULTI_1
JA
R20724 G1
J186
J7
J177
AC PWR
R20524 G2
J175
P177
P186
10
P3
R20580 G1
P178
P175
TI GATEWAY
P.C.B. ASSEMBLY
T20128 G2
A B REV
J187
R20525 G1
J5
DATA CONTROL
BOARD Q13563 03
J2
P3
J3
POWER SUPPLY
P.C.B. ASSEMBLY
T20314 G1
P174
J174
TI/RFID
TRANSFORMER
SUBASSY
R20719 G1
R20206 G11
P601/
P708
J601/
J708
10
P182
DECIMALS:
2 PLACE ±
3 PLACE ±
ANGLES:±
FRACTIONS:±
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES.
TOLERANCES ON
CGILBARCO INC.
UNPUBLISHED
THIS PRINT IS THE PROPERTY OF
GILBARCO INC., N.C., U.S.A.
INFORMATION HEREON IS CONFIDENTIAL
AND MUST NOT BE REPRODUCED OR
RELEASED OUTSIDE GILBARCO WITHOUT
PROPER AUTHORIZATION.
GILBARCO CONFIDENTIAL
J182
P601
J601
R20718 G1
MATERIAL
FINAL PROTECTIVE FINISH
"B" SIDE
INDICATOR
LIGHT BOARD
Q13786 01
P181
16
GREENSBORO, N.C.
64301-0
APP
SYM
NO.
1 OF 2
R20720
SH
NO.
SCALE
NONE
EAN:
WMH
09/10/99
64489-0
EAN:
JTB
08/26/99
64455-0
REVISED SH INDEX.
ADDED: R20543 G3
& R20206 G11.
RMV: Q10895 01
FILTER; R20206 G9;
R20543 G1; AND
R20543 G2.
REVISED SH INDEX
CHNG: R20206 G10
WAS G9. RMV:
CONNECTION E2;
DASHES FROM ALL
PART NUMBERS.
DESCRIPTION
REVISIONS
DIAGRAM, TRIND
MULTI_1, BLOCK
SYM
WMH 07/13/99 TR
EAN NO.
CK
DR
J181
LIGHT/MICROREADER
P.C.B. ASSEMBLY
T20545 G1
P191
J191
J812
ANTENNA
HAND HELD
T20551 G1
U812
TO J601
SYSTEM CABLE
W02468
15
15
TO P601
MAIN POWER
SUPPLY ASSY
R20665 G2
TO J601/J708
SYSTEM CABLE
T19612
TO P601/P708
MAIN POWER
SUPPLY ASSY
Cable Block Diagrams
Cable Block Diagrams
3
REVISIONS
R20720
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
SYM
DESCRIPTION
RMV: DASHES FROM
ALL PART NUMBERS
JTB
EAN:
08/26/99
64455-0
J802C
BACKLITE
LCD
DISPLAY
ASSEMBLY
T20262
REFLECTOR ASSY
0.6 INCH
T17622 G9
P802
J802B
J802A
20
REFLECTOR ASSY
0.6 INCH
T17622 G9
P802
REFLECTOR ASSY
0.6 INCH
T17622 G9
P802
P804
P801
J804
J801
34
P/O W03715 G2
P/O T19793 G3
NARROW FRAME DOOR ONLY
CGILBARCO INC.
UNPUBLISHED
THIS PRINT IS THE PROPERTY OF
GILBARCO INC., N.C., U.S.A.
INFORMATION HEREON IS CONFIDENTIAL
AND MUST NOT BE REPRODUCED OR
FINAL PROTECTIVE FINISH
DIAGRAM, TRIND
MULTI_1, BLOCK
RELEASED OUTSIDE GILBARCO WITHOUT
PROPER AUTHORIZATION.
T20538
Page 25
NEXT ASSY
S0001731
TRIND MULTI_1
USED ON
APPLICATION
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES.
TOLERANCES ON
DECIMALS:
2 PLACE ±
3 PLACE ±
FRACTIONS:±
GREENSBORO, N.C.
MATERIAL
DR
WMH 07/13/99
CK
EAN NO.
64301-0
ANGLES:±
TR
SCALE
APP
SH
NO.
SYM
NO.
NONE
R20720
Cable Block Diagrams
GILBARCO CONFIDENTIAL
Cable Block Diagrams
© 1999 Gilbarco, Inc. • 7300 West Friendly Avenue • Post Office Box 22087 • Greensboro, North Carolina 27420 • Phone (336) 547-5000 • http://www.gilbarco.com
MDE- 3801
10/99
Printed in the U.S.A.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.1
Linearized                      : No
Page Count                      : 26
Page Mode                       : UseOutlines
Create Date                     : 1999:10:01 15:47:20
Producer                        : Acrobat Distiller 3.01 for Windows
Title                           : Untitled Document
Creator                         : FrameMaker 5.5.6p145
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N6SGBIRA