Gilbarco MRIR11 Point of Sale Mat Reader System User Manual

Gilbarco Inc. Point of Sale Mat Reader System

Manual

Download: Gilbarco MRIR11 Point of Sale Mat Reader System User Manual
Mirror Download [FCC.gov]Gilbarco MRIR11 Point of Sale Mat Reader System User Manual
Document ID153621
Application IDSEP2QzqMD7Q9xF1OvOeIJA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize124.76kB (1559523 bits)
Date Submitted2001-06-07 00:00:00
Date Available2001-06-07 00:00:00
Creation Date2001-05-31 16:14:42
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2001-05-31 16:15:54
Document TitleUntitled Document
Document CreatorFrameMaker 5.5.6p145

MDE-4017
TIRIS™ Transmitter/Receiver Mat Reader
Assembly Kit C00016-XXX Installation
May 2001
Introduction
Purpose of this Manual
This manual provides instruction for installing TIRIS™ Mat Reader Assembly Kit C00016XXX.
Pr
el
05 im
/2 i
4/ n
01 a
ry
The TIRIS™ option allows customers to automatically authorize non-cash sales using a handheld transponder tag.
Important Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy, and if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense. Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate this equipment.
The long term characteristics or the possible physiological effects of radio frequency
electromagnetic fields have not been investigated by Underwriters’ Laboratories, Inc. (UL®).
Required Reading
Before installing the equipment, the installer must read, understand, and follow:
• this manual
• NFPA 70, The National Electric Code
• applicable federal, state and local codes and regulations
Failure to do so may adversely effect the safe use and operation of the equipment.
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Page 1
Related Documents
Installer must obtain, read and understand all site preparation documentation provided by the
point of sale company authorizing the installation before attempting to install this equipment.
In addition, the installer must be familiar with the information in the following documents.
Document
Number
Title
GOLD Library
MDE-3110
PC-Based G-SITE System Installation Manual
G-SITE
MDE-3111
PC-Based G-SITE System Start-Up and Service Manual
MDE-3620
Gilbarco POS Console Site Preparation Manual
• G-SITE
• Service Manual
Pr
el
05 im
/2 i
4/ n
01 a
ry
Site Prep
Required Tools
The following equipment is needed to install all TIRIS™ mat reader kits:
• drill motor and bits
• needle nose pliers
• screwdriver, Phillips® head
• Zircon® stud/bracket finder
Parts Lists
C00016-006 Kits contain the following parts:
Description
Part Number
Quantity
box, interface assembly
M01814A001
tape, neoprene foam
M01870B001
channel, plastic filler
M01871B001
cable, mat reader drive
M01872A001
tape, acrylic foam
K85492-72
power supply
M01878B001
jack, jump, push-to-start
Q11011-01
cable, data, CAT-5
Q13482-06
clamp, cable, stick on, small
Q13459-01
document, installation (this document)
MDE-4017
diagram, block and/or interconnect
M01873
The following components are also required.
Page 2
Description
Part Number
Quantity
graphics
MR01002G003
reader, mat, TIRIS device
Note: The Mat Reader is delivered with
the graphics in place.
M01787B001
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Important Safety Information
This section introduces the hazards and safety precautions associated with installing,
inspecting, maintaining or servicing this product. Before performing any task on this product,
read this safety information and the applicable sections in this manual, where additional
hazards and safety precautions for your task will be found. Electrical shock could occur and
cause death or serious injury if these safe service procedures are not followed.
Preliminary Precautions
Read, understand and follow this manual and any other labels or related materials supplied
with this equipment.
Follow the Regulations
Pr
el
im
05
/2
4/
01
in
ar
There is applicable information in: NFPA 70: National Electrical Code (NEC); OSHA
regulations; and federal, state, and local codes which must be followed. Failure to install,
maintain or service this equipment in accordance with these codes, regulations and standards
may lead to legal citations with penalties or affect the safe use and operation of the equipment.
Page 3
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Safety Symbols and Warning Words
Alert Symbol
This safety alert symbol is used in this manual and on warning labels to alert you to a
precaution which must be followed to prevent potential personal safety hazards. Obey safety
directives that follow this symbol to avoid possible injury or death.
Signal Words
Pr
el
05 im
/2 i
4/ n
01 a
ry
These signal words used in this manual and on warning labels tell you the seriousness of
particular safety hazards. The precautions that follow must be followed to prevent death,
injury or damage to the equipment.
DANGER
This signal word is used to alert you to a hazard or unsafe practice which will result in
death or serious injury.
WARNING
This alerts you to a hazard or unsafe practice that could result in death or serious injury.
CAUTION
This signal word designates a hazard or unsafe practice which may result in minor injury.
CAUTION
When used by itself, CAUTION designates a hazard or unsafe practice which may result in
property or equipment damage.
Proper Grounding is Required
Proper grounding is required for safe operation. See installation manual and applicable NEC,
NFPA and local electrical codes for requirements.
Avoid Pinched Wires
Pinched or cut wires (cables) may damage components. Exposed wires could create sparks and
electrical shorts when applying power.
Other Useful Safety Information
Replacement Parts
Use only genuine Marconi replacement parts. Using parts other than genuine Marconi
replacement parts could create a safety hazard, violate national, state and local regulations or
void warranty.
Page 4
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Installation
Note: All installation work is to be accomplished between the hours specified by the point of
sale company authorizing the installation.
Install Mat Reader assembly according to the following:
1 Collect and arrange all tools and equipment.
2 If necessary for installation of kit in area specified by point of sale company, remove
advertisement panels, saving all mounting hardware for re-use later.
Note: Make note of non-reusable fasteners, ensuring adequate replacements are available for
later use.
Setting Baud Rate
1 Remove Mat Reader Interface Box cover to access logic board.
ar
Figure: Mat Reader Interface Box Cover
el
im
05
/2
4/
01
in
cover screw
2 Locate jump jacks on logic board for Mat Reader.
Pr
Figure: Jump Jacks for Baud Rate Setting
Page 5
BAUD
124
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
3 Set the jump jacks as follows (see “Figure: Jump Jacks for Baud Rate Setting” on page 5).
CAUTION
Electrostatic Discharge Damage
Working on electronics without connecting to a ground or discharging
static can damage electronic parts. Use a wrist strap.
Mat Reader Baud Rates
Baud Rate (Note)
BAUD 1 BAUD 2 BAUD 4
OUT
OUT
OUT
2400
IN
OUT
OUT
Pr
el
05 im
/2 i
4/ n
01 a
ry
4800
1200
OUT
IN
OUT
300
IN
IN
OUT
38400
OUT
OUT
IN
19200
IN
OUT
IN
9600
OUT
IN
IN
4800
IN
IN
IN
Note: 4800 is the default value and the Mat Reader value.
4 If not daisychaining Mat Reader Interface Boxes, reinstall cover.
Note: Daisychaining is connecting the output from one Interface Box to the input of another.
Addressing Logic Board - Only for Daisychaining
Address for Mat Reader must match address on previously installed Mat Reader. Follow these
steps:
1 Access logic board for Mat Reader being installed.
2 Locate jump jacks on previously installed Mat Reader logic board M01803A001.
Figure: Jump Jacks for Address Setting
ADDR
1 2 4 8 16
Page 6
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
3 Note position of jump jacks on previously installed Mat Reader logic board, and set jump
jacks on board for Mat Reader being installed to match address on logic board.
CAUTION
Electrostatic Discharge Damage
Working on electronics without connecting to a ground or discharging
static can damage electronic parts. Use a wrist strap.
Mat Reader Addresses
Address on Logic Board
M01803A001
ADDR 1 ADDR 2 ADDR 4 ADDR 8 ADDR 16
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
OUT
IN
OUT
IN
OUT
OUT
OUT
IN
IN
OUT
OUT
in
ar
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
IN
OUT
IN
OUT
OUT
IN
OUT
05
/2
4/
01
el
im
10
Pr
OUT
IN
OUT
IN
OUT
11
IN
IN
OUT
IN
OUT
12
OUT
OUT
IN
IN
OUT
13
IN
OUT
IN
IN
OUT
14
OUT
IN
IN
IN
OUT
15
IN
IN
IN
IN
OUT
16
OUT
OUT
OUT
OUT
IN
17
IN
OUT
OUT
OUT
IN
18
OUT
IN
OUT
OUT
IN
19
IN
IN
OUT
OUT
IN
20
OUT
OUT
IN
OUT
IN
21
IN
OUT
IN
OUT
IN
22
OUT
IN
IN
OUT
IN
23
IN
IN
IN
OUT
IN
24
OUT
OUT
OUT
IN
IN
25
IN
OUT
OUT
IN
IN
26
OUT
IN
OUT
IN
IN
27
IN
IN
OUT
IN
IN
28
OUT
OUT
IN
IN
IN
29
IN
OUT
IN
IN
IN
30
OUT
IN
IN
IN
IN
31
IN
IN
IN
IN
IN
4 Reinstall cover.
Page 7
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Mounting Mat Reader Interface Box
1 Determine the location for the installation of indoor equipment.
Note: Refer to site prep document provided by point of sale company and keep in mind overall
length of cable to connect Mat Reader Interface Box to Mat Reader.
2 Use a Zircon stud/bracket finder to ensure no electrical conduits or pipes are located inside of
wall where the Mat Reader Interface Box is to be mounted. Also, ensure the Mat Reader
Interface Box is to be located where studs or wall (concrete/brick/drywall) mollys can be used
for mounting.
3 Mark and drill holes. Insert wall mollys as required.
Pr
el
05 im
/2 i
4/ n
01 a
ry
CAUTION
Do not use the Mat Reader Interface Box as a drill guide. It may be used as a template to
mark the holes to be drilled.
4 Use appropriate mounting hardware to secure the Mat Reader Interface Box to the wall.
Figure: Mat Reader Interface Box Mounting Holes
mounting holes
Page 8
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Connecting Data Cables to Mat Reader Interface Box
Run both power and data cables to port end of Mat Reader Interface Box (see “Figure: Mat
Reader Interface Box Mounting Holes” on page 8) as follows.
1 Connect the P3 end of the ribbon cable (M01872A001) to the RFID interface port (P3) .
2 Connect the J1end of the CAT-5 cable (Q13482-06) to the J1IN port.
Connect power supply here.
Connect J1 end of
CAT-5 cable here.
ar
Figure: Connecting to Mat Reader Interface Box
Connect P3 end of
ribbon cable here.
Pr
el
im
05
/2
4/
01
in
If daisychaining, connect
CAT-5 from J1IN on other
interface box here.
Page 9
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Connecting Data Cables from the Mat Reader Interface Box
1 Position Mat Reader face down.
Figure: Bottom Side of Mat Reader
bottom side of
neoprene foam
tape (flipped over
to show connector)
bottom side of
Mat Reader
Pr
el
05 im
/2 i
4/ n
01 a
ry
7-pin connector
channel for ribbon
cable (acrylic foam
tape in place)
2 Select side for ribbon cable (M01872A001) connection based on counter top configuration
requirements.
3 Install strip of acrylic foam tape (K85492-72) in base of channel on side selected for ribbon
cable.
4 Peel second release liner, exposing adhesive.
5 Carefully connect the P1/P2 end of the ribbon cable (M01872A001) to the back side of the
Mat Reader.
Note: The cable can be plugged in from either side. Since the cable is not keyed, the
orientation does not matter. Be sure the cable will be flat and not twisted once the Mat
Reader is face up.
Page 10
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Figure: Connecting to Mat Reader
bottom side of
neoprene foam tape
ribbon cable
connected to 7pin connector
ar
unused channel filled with plastic filler channel
and covered by neoprene foam tape
6 Install neoprene foam tape (M01870B001) over ribbon cable and sides of channel. Foam tape
in
should fit snugly into cutout of surrounding foam tape backer.
05
/2
4/
01
7 On unused cable channel, install plastic filler channel (M01871B001).
im
8 Install remaining neoprene foam tape (M01870B001) over filler channel. Foam tape should fit
snugly into cutout of surrounding foam tape backer.
9 Gently turn the Mat Reader to the face-up position.
Pr
el
Figure: Mat Reader - Face Up
10 Connect the loose end of the CAT-5 cable to the RS-232-1 or RS-232-2 port on the back of the
G-SITE system.
Note: The exact G-SITE system port depends on the G-SITE system configuration.
Page 11
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Connecting Power Supply
Connect the power supply (M01878B001) provided with kit as shown.
1 Plug the wall-mounted transformer into the AC power outlet.
Note: This AC power outlet must be on the same circuit as the G-SITE system.
2 Connect the plug end of the power supply cable to the JDC1 port on the Mat Reader Interface
Box (see “Figure: Connecting to Mat Reader Interface Box” on page 9).
Figure: Power Supply (M01878B001)
plugs into JDC1 port
Pr
el
05 im
/2 i
4/ n
01 a
ry
plugs into AC power outlet
wall-mounted
transformer
Page 12
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Completing Installation
Figure: Mat Reader Connections
power supply
interface box
CAT-5 cable
connects here
05
/2
4/
01
ribbon cable
in
ar
Mat Reader
im
1 Dress all cables and secure with stick on cable clamps (Q13459-01).
2 Clean up the work area.
Pr
el
3 Go to “Commissioning and Warranty Information” on page 14.
Page 13
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001
Commissioning and Warranty Information
Upon completion and testing the Mat Reader system, the installing contractor must call the
Marconi Commerce Systems Call Center @ 1-888-800-7498 to register the installation and
activate the warranty. Note the installed unit’s full Model Number (C00016-XXX) and serial
number before making this call.
• All Mat Readers have a one-year parts only warranty.
Note: Parts are to be returned through and obtained from the local Marconi distributor.
• Labor warranty, if any, is unit and customer specific.
Pr
el
05
/2
im
4/ in
ar
Marconi Commerse Systems strongly recommends using only Marconi trained ASCs
(Authorized Service Contractors) to perform service on the units. Use of non-authorized
service personnel to repair or service these units may void warranty. Call your local distributor
for service.
TRIND® is a registered trademark of Marconi Commerce Systems Inc.
Phillips® is a registered trademark of Phillips Screw Company.
UL® is a registered trademark of Underwriters’ Laboratories, Inc.
Zircon® is a registered trademark of Zircon International Inc.
© 2001 Marconi Commerce Systems Inc.
7300 West Friendly Avenue • Post Office Box 22087
Greensboro, North Carolina 27420
Phone (336) 547-5000 • http://www.marconicommerce.com • Printed in the U.S.A.
MDE-4017 TIRIS™ Transmitter/Receiver Mat Reader Assembly Kit C00016-XXX Installation • May 2001

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2001:05:31 16:14:42
Producer                        : Acrobat Distiller 4.05 for Windows
Title                           : Untitled Document
Creator                         : FrameMaker 5.5.6p145
Modify Date                     : 2001:05:31 16:15:54-04:00
Page Count                      : 14
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N6SMRIR11

Navigation menu