DUCTMATE® 35 Application and Design Ductmate® is used to connect a damper sleeve to a rectangular duct when a tight duct connection is required. The Ductmate connector gives a nearly airtight cross connection without the use of slip joints, and is an acceptable breakaway connection when installed properly. Particular attention should be given to the length of the sleeve extending beyond the wall or floor. The determining factor is dependent on whether or not there is an actuator and/or access door. If there is no actuator and/or factory mounted access door, the maximum is 6 inches (152mm) extending beyond the wall or floor. If there is an actuator or factory access door on the side of the wall, the maximum is 16 inches (406mm). Versa-cleats are available in packages of 10, 25, or 50. See installation instructions for spacing of cleats (468502 Quick Connect Breakaway Supplement). Standard Construction Flange: 2 0 ga. (1mm) galvanized Corner Clips: Galvanized Gasket: Extruded butyl for use between mating flanges (not supplied by Greenheck) Sleeve: Maximum thickness - 16 ga. (1.5mm) galvanized steel Mounting Options One side: Actuator side (FSD/SMD series) K side (DFD/FD series) Both Sides: Actuator or K side attached/ Opposite side unattached or both sides mechanically fastened Size Limitations Screw Spacing Schedule (per Ductmate instructions) Duct wall size inches (mm) 0-4 in. wg (0 - 1 kPa) 6 in. wg (1.5 kPa) 0-24 (0 - 610) 1 screw each corner 1 screw each corner 25-48 (635 - 1219) 1 screw each corner plus 1 @ center 1 screw each corner plus 1 @ center 49 and over (1245 and over) 1 screw each corner plus 1 screw each 24 inches (610mm) 2 screws each corner plus 1 screw each 24 inches (610mm) FSD/SMD series: Minimum damper size is 8 in. W x 6 in. H (203mm x 152mm) Maximum width is based on model limitations. Maximum height is limited to 84 inches (2133mm). FD/DFD series: Minimum damper size is 6in. W x 6 in. H (152mm x 152mm) Maximum width and height is based on model limitiations. Copyright © 2007 Greenheck Fan Corporation Ductmate® 35 Rev. 4 May 2007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-702 About : 6acab8f7-79ec-11d9-a3c6-def9293272b7 Create Date : 2007:05:04 08:24:06-05:00 Metadata Date : 2007:05:08 16:02:59-05:00 Modify Date : 2007:05:08 16:02:59-05:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 8905 bytes, use -b option to extract) Instance ID : uuid:410df292-aa1f-43bf-b86a-4dd52f9fa8fb Document ID : adobe:docid:indd:665fd60d-fa38-11db-ac84-b774633a3672 Rendition Class : proof:pdf Derived From Instance ID : 91a4d958-f8fb-11db-9566-8afdb76ff09e Derived From Document ID : adobe:docid:indd:6acab8f5-79ec-11d9-a3c6-def9293272b7 Manifest Link Form : ReferenceStream Manifest Placed X Resolution : 72.00 Manifest Placed Y Resolution : 72.00 Manifest Placed Resolution Unit : Inches Manifest Reference Instance ID : uuid:109843B83F94DA11BAD1D23B39E671BC Manifest Reference Document ID : uuid:0F9843B83F94DA11BAD1D23B39E671BC Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 1 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools