HAHNTECH REH-100 Two Way Personal Communicator (Module) User Manual Revised Users Manual
HAHNTECH Co., Ltd. Two Way Personal Communicator (Module) Revised Users Manual
HAHNTECH >
Contents
- 1. Users Manual
- 2. Revised Users Manual
- 3. Users Manual per CRN18783
Revised Users Manual
(REH-100) User Manual
HahnTech, Co., Ltd.
REH-100
User Manual
2004 November 12
Hahntech. Co.,Ltd.
(REH-100) User Manual
HahnTech, Co., Ltd.
Contents
1. PRODUCT DESCRIPTION......................................................................... 4
1.1. Introduction ................................................................................................................ 4
1.2. Protocol Support ......................................................................................................... 4
1.2.1. ReFLEX™ Protocol ....................................................................................................4
1.2.2. Communications Link Protocol (CLP) ...........................................................................5
1.2.3. GOTAP Support ........................................................................................................5
1.3. Console Interface ........................................................................................................ 6
1.3.1. COM Port Connection ................................................................................................6
1.3.2. to work with Console mode........................................................................................6
1.4. Messaging Behaviour................................................................................................... 6
1.5. Module Configuration .................................................................................................. 6
2. REH CONFIGURATOR SW OPERATION MANUAL ...................................... 7
2.1. Introduction ................................................................................................................ 7
2.2. System Parameters ..................................................................................................... 8
2.3. Global Scan List Parameters ........................................................................................ 9
2.4. Information Service Address List Parameters ........................................................... 10
2.5. SPID Parameters ....................................................................................................... 11
3. CLP COMMUNICATOR SW OPER MANUAL (UAR TX) .............................. 12
3.1. Introduction .............................................................................................................. 12
3.2. Setting Connection .................................................................................................... 12
3.3. Connect ..................................................................................................................... 13
3.4. Send Message............................................................................................................ 14
(REH-100) User Manual
HahnTech, Co., Ltd.
APPENDIX ................................................................................................ 15
A.1. Supported CLP Commands List .................................................................................. 15
A.2. RF Specifications ..................................................................................................... 156
A.3. Hardware Characteristics .......................................................................................... 17
A.3.1. Environmental ....................................................................................................... 17
A.3.2. Electrical Interface..............................................................................................................................................17
(REH-100) User Manual
HahnTech, Co., Ltd.
1. Product Description
1.1. Introduction
z Max Outbound (Receive) Message Size : 10,000 bytes
z Max Inbound (Transmit) Message Size : 2,000 bytes (possible to limit with PPS)
z Forward MSN Window Size : 12
z Reverse MSN Window Size : 8
1.2. Protocol Support
1.2.1. ReFLEX™ Protocol
z The module implements Motorola’s ReFLEX™ 25 protocol at Version 2.7.2
z Coasting: Radio coasts up to 32 frames.
z Number of Scan frequencies: 16 between 929-942 MHz
z Number of Scan ID’s (SCID): 5
z MSN management functions
Transaction Status interactions
Memory status transactions
Reception of messages in the alphanumeric and binary vector formats.
Transmission of short inbound messages and scheduled inbound messages
One primary address, “personal” address, and 16 information addresses are provided.
(REH-100) User Manual
HahnTech, Co., Ltd.
1.2.2. Communications Link Protocol (CLP)
z This is the protocol developed for the Motorola Creatalink, as defined in FLEXSuite™.
z It has been adapted for use with the WAM and provides all of the required messaging,
configuration and control functions.
z This interface has the following functions:
9 Messaging - Transmission
9 Messaging - Reception
9 Event signalling
9 Status and diagnostics information
9 Device configuration and control
z We insert additional CLP Commands (not include in FLEXSuite™)
9 Get-PPS : 0x90 - Get parameters of device.
9 Set-PPS : 0x91 - Set parameters of device.
9 UAR Message Transmission : 0x92 - Process UAR message
1.2.3. GOTAP Support
z The module recognizes the FLEXSuite™ GOTAP protocol for Over The Air (OTA)
configuration and control.
z Registration Not Required Command
z Program Without ACK Command
GOTAP Write
z HIX, IS Add, Delete, Modify
z Delete All IS
z SPID Add, Modify, Delete, Delete All
z GSL Add, Modify, Delete, Delete All
z Software Patch Version Number Command
z Enable or disable privacy option
GOTAP Write Special Access
z Password Change
z multi-byte write
GOTAP Read
z HIX
z IS
z SPID
z GSL
z Model
z Ver.
z Patch
z privacy flag
z multi-byte read
(REH-100) User Manual
HahnTech, Co., Ltd.
1.3. Console Interface
1.3.1. COM Port Connection
Baud Rate : 115200 bps
Data Bits : 8
Parity : None
Stop Bits : 1
Flow Control : None
1.3.2. to work with Console mode
z REH-100 have 2 types of mode, CLP mode and Console mode.
z CLP mode interface with CLP communicator through serial com port.
z Console mode can not support CLP protocol, and print debug message to serial com port.
z REH-100 works with CLP mode by default.
z To work with Console mode, you must connect COM port between REH-100 and PC.
z And after reset REH-100, you can find following message.
Press 'c' key to use console...
z If you press 'c', you can work REH-100 with Console mode.
z It must be happen in 3 seconds. After 3 seconds, this works with CLP mode.
1.4. Messaging Behaviour
z Messages are stored in NV (non-volatile) storage while they reside in the module.
z It is possible for a message to be received more than once with the same MSN.
z If automatic read ACKs are enabled, a read acknowledge is automatically transmitted to
the network when a message is downloaded.
z Memory full rules - Device manage all possible message size. It can not be happened
that device go to memory full state.
1.5. Module Configuration
z They are all stored in NV Store, are given default values at the factory, and may be
modified in the field using the appropriate Windows application.
z Field configuration shall be done using the provided “REH Configurator” application.
z A serial port is required on the PC to connect to the module’s configuration port.
(REH-100) User Manual
2. REH Configurator SW Operation Manual
2.1. Introduction
z REH Configurator have 4 parts of configuration parameter.
9 System parameters
9 Global Scan List Parameters
9 Information Service Address List Parameters
9 SPID Parameters
z It can be selected by “View” menu or “Service Pane” directly.
HahnTech, Co., Ltd.
(REH-100) User Manual
2.2. System Parameters
z System parameters consists of 3 parts
9 Main system parameters
9 Protocol parameters
9 GOTAP Passwords
Home Index : HIX value
Address : Personal device address
TCXO tune : Independently, unique tuning value of devices
Send Timeout : default 5 minutes
Max Inbound Message : 2000 (max)
z Default Protocol Parameter
9 hl : 63
9 ul : 10
9 dl : 6
9 ln : 0
9 mc : 0
9 n : 8 - autocollapse value
HahnTech, Co., Ltd.
(REH-100) User Manual
HahnTech, Co., Ltd.
2.3. Global Scan List Parameters
z Device can have 16 GSLs.
z You can choose “Max Spacing” - This is max non-sync frames.
z Quick Scan Channel : First of all device try connection to this frequency when start.
(REH-100) User Manual
2.4. Information Service Address List Parameters
z Device can have 16 Information Service Addresses.
9 PE : Priority Enable
9 GE : GOTAP Enable
9 En : address Enable
9 RM : Restricted Modify Enable
HahnTech, Co., Ltd.
(REH-100) User Manual
2.5. SPID Parameters
z Primary
z Pseudo-Primary
z Ancillary
HahnTech, Co., Ltd.
(REH-100) User Manual
HahnTech, Co., Ltd.
3. CLP Communicator SW Oper Manual (UAR Tx)
3.1. Introduction
z This program transmit message to device, with E-mail address.
z Now it supports only e-mail address (not wireless address).
3.2. Setting Connection
z It connect to device through serial communication, 9600 bps.
z Menu “Setting”/”Connection”
z Default connection is COM1/9600 bps.
(REH-100) User Manual
HahnTech, Co., Ltd.
3.3. Connect
z Menu “File”/”Connect” : Connection
z Menu “File”/”Disconnect” : Connection close
z If you click menu “File”/”Connect”, you can see below message.
Connected – Port: COM1 BaudRate: 9600
(If you cannot find this message or see another message, connection fail)
(REH-100) User Manual
HahnTech, Co., Ltd.
3.4. Send Message
z You first choice message type
9 Alphanumeric : Alpha-numeric message
9 HexBin : Binary message
z This communicator can support only e-mail address
z In binary message mode, characters must be numerics (0~9) and 12 characters (A~F,
a~f).
(REH-100) User Manual
Appendix
A.1. Supported CLP Commands List
A.2. RF Specifications
HahnTech, Co., Ltd.
(REH-100) User Manual
HahnTech, Co., Ltd.
(REH-100) User Manual
HahnTech, Co., Ltd.
A.3. Hardware Characteristics
A.3.1. Environmental
Operating Temperature Range
-10 ~ +60 ℃
Storage Temperature Range
-40 ~ +95 ℃
Relative Humidity
95% non-condensing
Vibration specification
TIA/EIA 603 3.3.4
Shock specification
TIA/EIA 603 3.3.5
A.3.2. Electrical Interface
Pin Number
10
11
12
13
14
15
16
17
18
19
20
Signal Name
UART_TX
TEST0
UART_RX
TEST1
OPEN
OPEN
IO3
IO2
TEST2
IO1
EN
IO0
GND
MRESET
GND
VEE_IN
GND
VEE_IN
GND
VEE_IN
Description
Transmit Data
Reserved
Received Data
Reserved
OPEN
OPEN
Input-Output Port3/Reserved
Input-Output Port2/Reserved
Reserved
Input-Output Port1/Reserved
Enable Device
Input-Output Port0/Reserved
Ground
Module Reset
Ground
Power to the board
Ground
Power to the board
Ground
Power to the board
!! "
&!
()
!!
&!
("
'*
'#
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2005:03:04 10:18:21-05:00 Create Date : 2004:11:12 18:54:52+09:00 Company : 한테크 Source Modified : D:20041112095433 Page Count : 18 Has XFA : No About : uuid:52ee4e40-0524-4e32-afdb-c52ad338f4f9 Producer : Acrobat Distiller 6.0 (Windows) Creation Date : 2004:11:12 18:54:52+09:00 Mod Date : 2005:03:04 10:18:21-05:00 Author : 오영환 Headline : Creator Tool : Acrobat PDFMaker 6.0 for Word Metadata Date : 2005:03:04 10:18:21-05:00 Keywords : Document ID : uuid:cbea4a5b-4d83-4ad9-9bce-6e345c0773ff Version ID : 4 Format : application/pdf Title : ReFLEX 관련 SW팀 향후 진행 업무 보고서 Creator : 오영환 Subject : Tagged PDF : YesEXIF Metadata provided by EXIF.tools