HANWAY TECHNOLOGY QV50L VENTILATION FAN User Manual

HANWAY TECHNOLOGY CO., LTD. VENTILATION FAN Users Manual

USERS MANUAL

Download: HANWAY TECHNOLOGY QV50L VENTILATION FAN User Manual
Mirror Download [FCC.gov]HANWAY TECHNOLOGY QV50L VENTILATION FAN User Manual
Document ID908916
Application IDQAtcSGIxZN+YiLAlNeqSrA==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize72.12kB (901470 bits)
Date Submitted2008-03-03 00:00:00
Date Available2008-03-03 00:00:00
Creation Date2008-01-15 15:37:30
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2008-02-29 16:59:08
Document TitleUsers Manual
Document CreatorPScript5.dll Version 5.2
Document Author: lyl

INSTALLATION INSTRUCTIONS
Quiet Ventilation Fan/
Light/Nightlight
Quiet Decorative Ventilation
Fan/Light/Nightlight
Models QV50L/QV80L/QV110L/QV150L
Models QDV70L/QDV80L/QDV90L/
QDV110L/QDV130L/QDV150L
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
GENERAL SAFETY INFORMATION................................................ ......... ................. .................. ....... ...2
DESCRIPTION...................................................................................................................................3
COMPONENT PARTS.........................................................................................................................3
DIMENSIONS....................................................................................................................................4
SPECIFICATIONS..............................................................................................................................4
INSTALLATION..................................................................................................................................5
CLEANING & MAINTENANCE..............................................................................................................7
TROUBLE SHOOTING GUIDE.............................................................................................................7
SERVICE PARTS................................................................................................................................8
WARRANTY......................................................................................................................................9
The Honeywell trademark is used under license from Honeywell Intellectual Properties Inc.
by Lonon Industry Company, Ltd.
Honeywell International Inc. makes no representations or warranties with respect to this product.
GENERAL SAFETY INFORMATION
1. Do not install this ventilating fan where air temperature may exceed 104 F (40 C).
2. Make sure that the electric service supply voltage is 120V, 60Hz.
3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation
Safety and Health Act (OSHA).
4. Always disconnect the power source before working on or near the fan, motor or junction box or light fixture.
5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
6. Do not kink the power cord.
7. This unit is approved for use over a bathtub or shower when installed in a GFCI protected branch circuit.
8. This unit must be grounded.
9. This unit is U.L. Listed. Type I.C. Inherently protected.
10. These models are UL listed for tub and shower enclosures.
11. Provide suction parts with proper ventilation.
12. Do not install the unit where ducts are configured as shown in Fig.A.
Fig.A
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
1. Use this unit only in the manner intended by Lonon USA, LLC . If you have questions, please contact
Lonon USA, LLC at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch the power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and
safety standards, such as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, make sure not to damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from a tub or shower.
8. Please note that solid state controls may cause harmonic distortion that can cause motor humming
noise.
9. To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
10. Not to be in a ceiling thermally insulated to a value greater than R40.
11. Fluorescent models only: Do not use a dimmer switch to control the light of this unit.
12. Motor and grille assembly must be installed with housing assembly that are marked (on their cartons) to
indicate the suitability with this model. Other housing assembly cannot be substituted.
13. To reduce the risk of fire use only these 18 watt fluorescent lamps and 4 watt maximum type C
incandescent lamp nightlight.
Page 2
GENERAL SAFETY INFORMATION ( Continued )
CAUTION:
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only. This
product is designed for installation in ceilings up to a 12/12
pitch. Ductwork must point up. DO NOT MOUNT THIS
PRODUCT ON A WALL.
3. The light fixture assembly must be mounted to the fan
housing assembly included with this product. Do not mount
the fight fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and / or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
5. Please read specification label on product for further
information and requirements.
6. Not for use in cooking area (Fig. B).
(Cooking area)
Do not install above or
inside this area
45
45
Floor
Cooking
equipment
Fig.B
DESCRIPTION
Thank you for selecting this high quantity Honeywell ventilation fan. Honeywell ventilation fans were designed with
your comfort in mind. With many different features, Honeywell fans fit your needs whether your bathroom is big or
small, needs a light, no light or even a nightlight, Honeywell fans have the features you need.
Honeywell ceiling mounted ventilation fans use a high-capacity sirocco fan driven by a capacitor motor. The sirocco
fan reduces the noise level.
Honeywell ventilation fans incorporate a thermal cut off for safety.
The grille unit can be quickly detached from the main unit for cleaning.
A damper for preventing air backdraft is incorporated into every fan.
The motor is designed to have an extended service life with reduced energy consumption.
The light unit is an energy efficient lighting device which uses two 18W compact fluorescent lamps.
COMPONENT PARTS
Part name
Picture
Quantity
Part name
Picture
Quantity
Glass sub-1
( glass grille )
Suspension
bracket A
(12.6inches/320mm)
Grille sub-2
Suspension
bracket B
(9.5inches/240mm)
Screw A
ST4X30
Suspension
bracket C
(6.3inches/160mm)
QV110L/150L
not supplied
Screw B
M4X10
18 W
fluorescent lamp
4W
Night lamp
Screw E
M5X20
Grille
Suspension
bracket D
(2.95inches/75mm)
QV110L/150L
not supplied
Suspension
bracket E
(5.3inches/135mm)
QV50L/80L
not supplied
Page 3
254-584mm
254-584mm
DIMENSIONS
Model No.
QV50L
QV80L
QV90L
QV110L
QV130L
QV150L
QDV70L
QDV80L
QDV90L
QDV110L
QDV130L
QDV150L
10 9/16"
10 "
5 1/2 "
4"
6 3/8 "
6"
5 1/2 "
4"
6 3/8 "
6"
12 5/16" 11 7/16 "
10 9/16"
10 "
12 5/16" 11 7/16 "
12 3/16 " 12 3/16 " 3 1/2 "½ 3 1/8 "
4 1/8 "
7 7/8 "
3 1/8 "
4 1/8 "
7 7/8 "½
12 3/16 " 12 3/16 " 3 1/2 "½ 3 1/8 "
4 1/8 "
7 7/8 "
3 1/8 "
4 1/8 "
7 7/8 "½
" 13 3/4¾
" 4 5/16 "
13 3/4¾
" 4 5/16 "
" 13 3/4¾
13 3/4¾
SPECIFICATIONS
Air
Movement
Light Unit
0.1" WG
Light Night Light
(CFM)
Power consumption*(W)
Model
No.
Power
Supply
QV50L
120V/60Hz
Fan
Unit
17.0
36.0
4.0
50
Noise
(sone)
<0.3
Duct
Diameter Weight
(lb.)
(inch)
9.9
QV80L
120V/60Hz
21.0
36.0
4.0
80
0.3
9.9
QV90L
120V/60Hz
24.0
36.0
4.0
90
0.5
9.9
QV110L
120V/60Hz
33.0
36.0
4.0
110
0.9
12.5
QV130L
120V/60Hz
36.0
36.0
4.0
130
0.8
12.5
QV150L
120V/60Hz
39.0
36.0
4.0
150
0.9
12.5
QDV70L
120V/60Hz
21.0
36.0
4.0
70
<0.3
15.32
QDV80L
120V/60Hz
23.0
36.0
4.0
80
0.5
15.32
QDV90L
120V/60Hz
24.0
36.0
4.0
90
0.5
15.32
QDV110L
120V/60Hz
32.0
36.0
4.0
110
0.3
19.29
QDV130L
120V/60Hz
35.0
36.0
4.0
130
0.6
19.29
QDV150L
120V/60Hz
41.0
36.0
4.0
150
1.0
19.29
*At 0.0" Static pressure (Pa).
Specifications are based on HVI standard.
Page 4
INSTALLATION ( The housing is in the middle of joists )
S1. Select the suspension bracket and insert them into the housing according to the table-1 as below.
table-1
The joists center distance A Insert the suspension bracket method Remark
Joists
16 inches
Refer to Fig.1 insert
19.2 inches or 24 inches
Refer to Fig.2 insert
Suspension
Bracket B
Suspension
Bracket D
Suspension
Bracket C
Housing
This method is not fit the
products QV110L/130L/150L
QDV110L/130L/150L
Suspension Bracket C
(for models QV50L/80L/90L)
(for models QDV70L/80L/90L)
Suspension Bracket E
(for models QV110L/130L/150L)
(for models QDV110l/130l/150l)
Suspension
Bracket A
Suspension
Bracket B
Housing
Fig.1
Fig.2
S2. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run
and minimum number of elbows. Mark the keyhole slot on both suspension brackets and keep the distance B for
the thickness of the ceiling board (Fig.3).
Keyhole slot
Keyhole slot
Fig.3
S3. Set housing aside and drive the screw A (ST4 30) partially into joists at the top of both keyhole marks (Fig.4).
Hang housing from the screw A and drive the screw A tight. To ensure a noise-free mount, drive other screw A
through the round holes of suspension brackets. Secure the suspension brackets to the housing by screw B
(M4 10) (Fig.5).
Screw A
(ST4 30)
2-Screw B
(M4 10)
2-Screw A
(ST4 30)
Housing
4-Screw A
(ST4 30)
Fig.5
Fig.4
S4. Remove the wiring cover and the knockout hole, make the electrical cable through the knockout hole, and
connect the house power wires to wires of the product according to the wiring diagram. Then secure the circular
duct ( 4 inches duct for QV50L/80L/90L QDV70L/80L/90L and 6 inches duct for QV110L//130L/150L
QDV110L/130L/150L ) with duct tape (Fig.6).
Wiring Diagram
Light unit
Electrical cable
18W Lamp
Night lamp
Fan unit
Blue
Motor
Condenser
White
Black
Earth Ground
Wiring box
Knockout hole
Electric
Ballast
Black
White
Black
White
White
Black
Green
18W Lamp
Black
White
Black
White
White
Black
Green
Green terminal
Circular duct
Power supply(120V~60Hz)
Wiring cover
Duct tape
Power supply(120V~60Hz)
Power supply(120V~60Hz)
Housing
Earth Ground
Earth Ground
Earth Ground
Fig.6
Page 5
INSTALLATION ( The housing is in the middle of joists )( Continued )
S5. Finish the ceiling work, ceiling hole should be kept for the product (Fig.7). Then insert the 18 watt fluorescent
lamps into the lighting unit and screw the 4 watt nightlight into the lighting unit (Fig.8).
Ceiling board
Ceiling board
Lighting unit
Lighting Housing
Housing
Housing
Fluorescent Lamp
Fig.8
Fig.7
S6. For models QV50L/80L/90L/110L/130L/150L, insert the grille springs into the slots of the casing and mount the
grille unit. Finish the installation work (Fig.9.1).
For models QDV70L/80L/90L/110L/130L/150L, secure the grille sub-2 to the housing by screw E (M5 20). Insert
the sliding shaft to the grille sub-2, then turn the grille sub-1 along the arrow mark and finish the installation work
(Fig.9.2).
Ceiling board
Ceiling board
Grille spring
Grille unit
Slot
Fig.9.1
Grille sub-2
Housing
Sliding shaft
Grille sub-2
4-Screw E
(M5 20
Sliding shaft
Ceiling board
Grille sub-1
Turning way of sliding shaft
Fig.9.2
INSTALLATION ( I-joists mounting )
S1. Insert the suspension bracket A into the housing and secure it to housing by screw B (M4 10) according to the
distance C in table-2 (Fig.10).
Table-2
4 kinds of I-joist
inches(mm)
C1
The suspension bracket A can accommodate
different kinds of I-joist.
9/16 (14.3)
C2 11/16 (17.5)
C3 31/32 (24.6)
C3
2-Screw B
(M4 10)
C2
Housing
C4 C1
C4 1 17//32 (38.9)
Suspension bracket A
Fig.10
S2. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run
and minimum number of elbows. Lock the flange of the product and the suspension bracket A tightly to the I-joist
by screw A (ST4 30) (Fig.11).
Housing
I-joist
4-Screw A(ST4
30)
Fig.11
S3. Please follow S4 to S6 of installation, ( page 5, page 6 ), to finish the installation work.
Page 6
CLEANING & MAINTENANCE
WARNING
1. Disconnect power source before working on unit.
2. The lamp's glass is fragile. Please handle with care. To remove lamp, grasp at base and move back and force to
loosen.
3. Do not pull hard on the lamp or you may break the glass.
4. 4W night lamp has threaded base. Remove by turning counterclockwise.
CAUTION
1. Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
2. Do not allow water to enter motor.
3. Metal and electrical parts should never be immersed in water.
4. Do not immerse resin parts in water over 140 F (60 C).
5. Allow bulb and lamps to cool before replacing.
CLEANING
Squeeze grill springs and pull grille down carefully. Use non-abrasive kitchen detergent wash, and wipe grille dry with
new cloth.
Remove bulbs, if necessary. Remove dust and dirt on fan body using vacuum cleaner. Using a cloth dampened with
mild dish soap, remove any dirt from fan body. Wipe dry with new cloth.
Replace bulbs and grille.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual
noises, replace the motor with the exact service motor. You must replace the impeller at the same time.
REPLACEMENT OF LAMP
Remove grille. Disconnect the connectors of light unit from fan unit. Change the 18W fluorescent bulb or the 4W
incandescent lamp, connect the connectors and replace the grille.
TROUBLE SHOOTING GUIDE
Problem: Fan does not come on.
Solution:
Honeywell ventilation fans are extremely quiet. To confirm that the fan is running, place your hand near the vents
to feel the air movement.
Turn power on, replace fuse, or reset breaker.
Check all plug connections to be sure they are secure.
Check the wiring to make sure it matches the wiring diagram.
Problem: Light does not come on.
Solution:
Replace the light bulb with a new bulb.
Turn power on, replace fuse, or reset breaker.
Check all plug connections to be sure they are secure.
Check the wiring to make sure it matches the wiring diagram.
Problem: Fan is noisy.
Solution:
Check and tighten all fasteners.
Check the flapper to make sure it moves freely.
Page 7
SERVICE PARTS (FOR QV50L/80L/90L/110L/130L/150L)
31 32 33 34
35 36
20
21
22
12 11 10 9
37
38
39
40
41
42
43
44
23
24
25
26
27
28
29
30
45
46
No.
Part name
13
14
No.
15
16 17
18 19
Part name
Damper
24
Motor setting screw
Adaptor setting screw
25
Motor
Adaptor
26
Motor support
Wiring box setting screw
27
Condenser
Wiring box
28
Casing setting screw
Housing
29
Condenser box
Ballast box support
30
Condenser box setting screw
Ballast box support setting screw
31
Fluorescent lamp
Bracket cover A
32
Night lamp
10
Bracket cover A setting screw
33
Lampholder setting screw
11
Suspension bracket A
34
Lampholder
12
Suspension bracket B
35
Lampholder cover setting screw
13
Casing support setting screw
36
Lampholder cover
14
Casing support
37
Ballast box
15
Wiring cover
38
Ballast
16
Bracket cover B
39
Ballast box cover setting screw A
17
Bracket cover B setting screw
40
Ballast box cover
18
Wiring cover setting screw
41
Ballast box cover setting screw B
19
Suspension bracket C
42
Spring hook setting screw
20
Casing
43
Spring hook
21
Blower wheel setting nut
44
Grille spring
22
Blower wheel setting washer
45
Grille
23
Blower wheel
46
Lamper cover
Page 8
SERVICE PARTS (FOR QDV70L/80L/90L/110L/130L/150L)
31 32 33 34
35 36
20
21
22
12 11 10 9
37
38
39
40
41
42
43
44
45
46
47
48
No.
23
24
25
26
27
28
29
30
Part name
13
14
No.
15
16 17
18 19
Part name
Damper
25
Motor
Adaptor setting screw
26
Motor support
Adaptor
27
Condenser
Wiring box setting screw
28
Casing setting screw
Wiring box
29
Condenser box
Housing
30
Condenser box setting screw
Ballast box support
31
Fluorescent lamp
Ballast box support setting screw
32
Night lamp
Bracket cover A
33
Lampholder setting screw
10
Bracket cover A setting screw
34
Lampholder
11
Suspension bracket A
35
Lampholder cover setting screw
12
Suspension bracket B
36
Lampholder cover
13
Casing support setting screw
37
Ballast box
14
Casing support
38
Ballast
15
Wiring cover
39
Ballast box cover setting screw A
16
Bracket cover B
40
Ballast box cover
17
Bracket cover B setting screw
41
Ballast box cover setting screw B
18
Wiring cover setting screw
42
Grille sub-2
19
Suspension bracket C
43
Nut (M5)
20
Casing
44
Sliding shaft
21
Blower wheel setting nut
45
Nut (M5)
22
Blower wheel setting washer
46
Bolt
23
Blower wheel
47
Glass grille hook
24
Motor setting screw
48
Glass grille
*These instructions may be printed in English ("the English version") and one or more other languages ("other versions"), in
which case the English version shall prevail if there is any inconsistency between the English version and any one or more of
the other versions.
Page 9
WARRANTY
LONON USA, LLC
LIMITED WARRANTY
Product Name:
Date of purchase:
Date of installation:
Model Number:
Dealer:
Builder/ Installer:
Warranty Period (from date of original purchase) ("Warranty Period"): Five (5) years for the motor; One (1) year for
other parts.
LIMITED WARRANTY. Lonon USA, LLC ("LONON") gives this limited warranty ("this Warranty") to the original
purchaser of the Product ("Buyer"), subject to the following terms: LONON warrants that the Product will be free
from original defects in materials and workmanship for the Warranty Period, PROVIDED (i) that the Product has been
properly stored, installed, serviced, maintained and operated; (ii) that the Product has not been altered or repaired in
any way which, in LONON's reasonable judgment, will affect its performance or reliability; and (iii) that the Product
has not been improperly installed or subjected to misuse, negligence, or accident, or incorrectly used in combination
with other articles. Save where provided otherwise in this Warranty, Buyer assumes all risks and liability for results
of use of the Product. Where applicable, warranties on purchased parts are limited to the terms of the warranties
extended by LONON's supplier(s). Without prejudice to the limitations and exclusions below, THIS WARRANTY
SHALL BE VALID ONLY IF THE PRODUCT IS PURCHASED AND INSTALLED IN THE UNITED STATES.
WARRANTY SERVICE. All claims under this Warranty shall be made in writing and delivered to LONON at the
address set out below within 15 days after discovery of the defect and prior to the expiration of the Warranty Period.
Buyer shall be barred from any remedy if Buyer fails to make such claim within such period. Within 30 days after
receipt of a timely claim, LONON shall have the option either to inspect the Product while in Buyer's possession or to
request Buyer to return the Product to LONON at Buyer's expense for inspection by LONON. Subject to the terms of
this Warranty, LONON will, during the Warranty Period, at its option replace or repair, free of charge, the Product or
part thereof which LONON determines is defective under normal use and maintenance.
This Warranty does not cover and LONON is not responsible for : (i) normal maintenance and service; (ii) any Product
which has been subjected to misuse, improper maintenance or modification, neglect, electrical current fluctuations,
negligence, accident, improper or faulty operation or installation or installation contrary to the installation
instructions, use of parts or supplies other than LONON's that cause damage to the Product, defacement, alteration,
or removal of a product serial number; (iii) the cost of removal of the defective Product or part, damages due to
removal, or any expenses incurred in shipping the defective Product or part to or from LONON's service centre, or
the installation of the repaired or replacement product or part; (iv) any glass component, light bulb, fluorescent lamp,
starter, tube, filter, duct, roof cap, wall cap or other ducting accessories even where the Product is equipped with any
of the same.
Subject to the above warranty, to the maximum extent permitted by applicable law: (i) LONON and its suppliers
provide the Product as is and hereby disclaim all other warranties and conditions whether express implied or
statutory, including without limitation implied warranties or conditions of merchantability and of fitness for a
particular purpose, and any responsibility for any loss of revenues or profits, inconvenience, expense for substitute
equipment or service, storage charges, or loss or corruption of data; (ii) implied warranties, when applicable, shall
commence upon the same date as the express warranty provided above, and shall, except for warranties of title,
extend only for the duration of the express warranty above; (iii) LONON assumes no liability on account of any
recommendations, opinions or advise as to the choice, installation or use of the Product, and any such
recommendations, opinions or advice given are accepted at the original purchaser's own risk and shall not
constitute any warranty or guarantee concerning any matter; (iv) in no event shall LONON and its suppliers be liable
for any special, incidental, punitive, indirect, or consequential damages whatsoever arising out of or in any way
related to the use of or inability to use the Product for whatever reason and based on whatever cause of action;
Page 10
WARRANTY ( Continued )
(v) the entire liability of LONON and its suppliers in relation to the manufacture and supply of the Product is limited to
the amount actually paid by the original purchaser for the Product. Damages are limited to the purchase price of the
Product.
This Warranty gives the Buyer specific legal rights. Some states do not allow limitation on how
long an implied warranty lasts, or exclusion of or limitation on incidental or consequential damages. The extent to
which the above limitations and exclusions are valid may vary from state to state.
No agent, dealer, employee or other person is authorized to give any other warranties or assume any other liability
on LONON's behalf in connection with the Product except in writing signed by an authorized officer of LONON.
Notwithstanding any past practice or dealings or any custom of the trade, the supply of the Product does not include
the provision of any technical advice or system design, which may be provided at LONON's sole option and subject
to additional charges.
This Warranty may be printed in English ("the English version") and one or more other languages ("other versions"), in which case
the English version shall prevail if there is any inconsistency between the English version and any one or more of the other versions.
FOR ASSISTANCE: PLEASE CONTACT
Lonon USA, LLC
Customer Service Centre:
4320 Winfield Road, Suite 200 Warrenville, IL 60555
Opening hours: Mon. - Fri. (except public holidays): 8:00 am to 3:30 pm
Toll free service hotline: 1-888-566-6687
IMPORTANT: The original invoice for the purchase of the Product together with this warranty card
must be presented in order to quality for service under this Warranty.
FCC NOTE
The manufacture is not responsible for any radio or TV interference caused by unauthorized modifications to this
equipment. Such modifications could void the user’s authority to operate the equipment. This product may cause
interference to radio equipment and should not be installed near maritime safety communications equipment or other
critical navigation or communication equipment operating between 0.45-30MHz.
Page 11
Version:A
Revision Data: 12/14/2005
CBT-213L-120S
APPLICATION and PERFORMANCE SPECIFICATION
Description: Electronic ballast for compact fluorescent Lamp (2)T4quad 4pin 13W or (2) T5 linear 13W/14W/28W
• Line Voltage : 120Vac, 60Hz
• Rapid Start
• Series Lamp Connection WS-3
Line
Model
Volts
Lamp
Type**
Freq-Hz
No.of
lamps
13W/6T4/Q/G24q-1
(Quad 4pin/PL-C 13W)
CBT-213L-120S
120
60
T5 linear 13W
T5 linear 14W
T5 linear 28W
Input
Nominal
Power
Crest
Watts*
Line Amps
Factor
Factor
29
0.44
30
0.44
0.56
<1.7
30
0.44
30
0.44
Case ULC #
#90-5B
*ANSI measured wattage,25℃ ambient,benchtop,lamps base up ; Enclosed fixture, wattage may change depending on fixture type.
Application and Performance Specification Information Subject to Change without Notification.
Performance:
Safety:
• Meets ANSI Standard C82.11-1993
• No PCB's
• Meets ANSI Standard C62.41-1991
• UL listed (Class P)
• Meets UL 935
• UL # 221323
• Meets FCC Part 18 (Class B) for EMI
• Operating Frequency Range: 45-55 kHz
• Abnormal Protection Circuit
• End of lamp life protection Circuit
• Auto-Reset Shutdown Circuit
- lamp(s) should be replaced at end of lamp life
- Lamp relights upon insertion in socket
Application:
Physical Parameters
• Minimum Starting Temperature:
5° F (-15° C)
Case:
CM-31(#90-5B)
• Maximum Ambient Temperature:
• Maximum Case Temperature (@ tc):
122° F(50° C)
158° F(70° C)
Overall Length(L):
Width(W):
3.86"(99mm)
2"(52mm)
• Sound Rated:
Mounting(M):
3.5"(90mm)
Height(H):
1.00"(25.4mm)
Weight:
0.55bs(0.25kg)
Qty/Carton:
30
Color:
Black
Can Material:
Metal
Black
320mm
Wire length:
White
300mm
(±25.4mm)
Blue
240mm*2
Red
240mm*2
Yellow
250mm*2
Red
White
Black
BALLAST
Blue
Install in accordance with
the National Electrical Code
Ballast must be grounded.
FCC NOTE:
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications
could void the user's authority to operate the equipment.
This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other
critical navigation or communication equipment operating between 0.450-30MHz.
Warranty:
Universal Lighting China warrants to the purchaser that each electronic ballast will be free from defects in material or
workmanship for a period of 3 years from date of manufacture when properly installed and under normal conditions of use.
Call 8621-64808118*218,128 for technical assistance.
○○○○☆☆
Manufactured in China

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
About                           : uuid:51c200f2-c56e-4c31-b583-28dd7a89286b
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:02:29 16:59:08+08:00
Create Date                     : 2008:01:15 15:37:30+08:00
Metadata Date                   : 2008:02:29 16:59:08+08:00
Document ID                     : uuid:8546c25f-7d34-4db1-a1ea-0f21e9f303a3
Instance ID                     : uuid:fb9a8777-5dfb-4c2e-a2e5-2e1fcf35f6d5
Format                          : application/pdf
Title                           : 
Creator                         : lyl
Has XFA                         : No
Page Count                      : 12
Author                          : lyl
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VYDQV50L

Navigation menu