HARRIS TR-0054-E Dual Band P7300 User Manual Manual

HARRIS CORPORATION Dual Band P7300 Manual

Manual

Download: HARRIS TR-0054-E Dual Band P7300 User Manual Manual
Mirror Download [FCC.gov]HARRIS TR-0054-E Dual Band P7300 User Manual Manual
Document ID1132261
Application IDNE//WDPQE+nI3QHBhMPdyg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize199.29kB (2491111 bits)
Date Submitted2009-07-01 00:00:00
Date Available2009-07-01 00:00:00
Creation Date2009-06-17 16:47:00
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2009-06-17 16:47:17
Document TitleMicrosoft Word - 2009141 MA-COM P7300 700_800 MHz FCC Test Report R1.0.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Kathy

Rhein Tech Laboratories, Inc.
360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
Appendix M:
Client: Harris Corporation
Model: P7300 UHF Radio
FCC ID: OWDTR-0054-E
Standards: FCC Part 90
Report #: 2009141
Manual
Please refer to the following pages for the manual.
60 of 75
Operator’s Manual
MM-013994-001
Rev. Ap1, Jun/09
P7300 FAMILY
PORTABLE RADIOS
UHF, 700/800 MHz
MM-013994-001, Rev. Ap1
MANUAL REVISION HISTORY
REV
DATE
REASON FOR REVISION
Jan/09
Initial release.
Jun/09
Added SAR information and support for dual band P7300 portable radio.
Harris Technical Publications would particularly appreciate feedback on any errors found in this document and suggestions on how the
document could be improved. Submit your comments and suggestions to:
Harris Corporation
RF Communications Division
Fax your comments to: 1-434-455-6851
Technical Publications
or
221 Jefferson Ridge Parkway
e-mail us at: techpubs@tycoelectronics.com
Lynchburg, VA 24501
ACKNOWLEDGEMENTS
The software contained in this device is copyrighted by Harris Corporation Unpublished rights are reserved under the copyright laws of the
United States.
This device is made under license under one or more of the following US patents: 4,590,473; 4,636,791; 5,148,482; 5,185,796; 5,271,017;
5,377,229; 4,716,407; 4,972,460; 5,502,767; 5,146,497; 5,164,986; 5,185,795; 5,226,084; 5,247,579; ; 5,491,772; 5,517,511; 5,630,011;
5,649,050; 5,701,390; 5,715,365; 5,754,974; 5,826,222; 5,870,405; 6,161,089; and 6,199,037 B1. DVSI claims certain rights, including
patent rights under aforementioned U.S. patents, and under other U.S. and foreign patents and patents pending. Any use of this software or
technology requires a separate written license from DVSI.
CREDITS!
EDACS is a registered trademark of Harris Corporation
AMBE is a registered trademark and IMBE, AMBE+, and AMBE+2 are trademarks of Digital Voice Systems, Inc.
TORX is a registered trademark of CAMCAR division of TEXTRON, Inc.
All other product and brand names are trademarks, registered trademarks, or service marks of their respective holders.
NOTICE!
Tyco Electronics (“TE”) has divested its Wireless systems business to Harris Corporation (“HARRIS”). As a result, all references herein to
TE or M/A-COM shall be to HARRIS. Neither TE nor M/A-COM is an agent or affiliate of Harris.
Information and descriptions contained herein are the property of Harris Corporation. Such information and descriptions may not be copied
or reproduced by any means, or disseminated or distributed without the express prior written permission of Harris Corporation, RF
Communications Division, 221 Jefferson Ridge Parkway, Lynchburg, VA 24501.
This manual covers Harris Corporation products manufactured and sold by Harris Corporation.
This product conforms to the European Union WEEE Directive 2002/96/EC. Do not dispose of this product in a public
landfill. Take it to a recycling center at the end of its life.
The voice coding technology embodied in this product is protected by intellectual property rights including patent rights, copyrights, and
trade secrets of Digital Voice Systems, Inc. The user of this technology is explicitly prohibited from attempting to decompile, reverse
engineer, or disassemble the Object Code, or in any other way convert the Object Code into human-readable form.
Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any repairs,
alterations, or substitution of recommended parts made by the user to this equipment not approved by the manufacturer could void the
user’s authority to operate the equipment in addition to the manufacturer’s warranty.
This manual is published by Harris Corporation, without any warranty. Improvements and changes to this manual necessitated by typographical errors,
inaccuracies of current information, or improvements to programs and/or equipment, may be made by Harris Corporation, at any time and without notice.
Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means,
electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of Harris Corporation
Copyright© 2009 Harris Corporation. All rights reserved.
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
Page
SAFETY CONVENTIONS..................................................................................................................12
SAFETY TRAINING INFORMATION ............................................................................................13
2.1
RF EXPOSURE GUIDELINES .................................................................................................13
2.2
ELECTROMAGNETIC INTERFERENCE/COMPATIBILITY...............................................14
OPERATING TIPS ..............................................................................................................................15
3.1
EFFICIENT RADIO OPERATION ...........................................................................................15
3.1.1 Antenna Care and Replacement.....................................................................................15
3.1.2 Electronic Devices .........................................................................................................15
3.1.3 Aircraft...........................................................................................................................16
3.1.4 Electric Blasting Caps ...................................................................................................16
3.1.5 Potentially Explosive Atmospheres...............................................................................16
BATTERIES .........................................................................................................................................17
4.1
CONDITIONING BATTERY PACKS......................................................................................17
4.1.1 Conditioning NiMH Battery Packs................................................................................17
4.1.2 Conditioning NiCd Battery Packs .................................................................................17
4.1.3 Additional Information ..................................................................................................18
4.2
CHARGING BATTERY PACKS ..............................................................................................18
4.2.1 Charging Guidelines ......................................................................................................18
4.3
BATTERY PACK USAGE........................................................................................................18
4.3.1 Usage Guidelines...........................................................................................................18
4.4
CHANGING THE BATTERY PACK .......................................................................................19
4.4.1 Removing the Battery Pack ...........................................................................................19
4.4.2 Attaching the Battery Pack ............................................................................................20
4.5
BATTERY DISPOSAL..............................................................................................................20
INTRODUCTION ................................................................................................................................22
5.1
WATER RESISTANCE.............................................................................................................22
OPTIONS AND ACCESSORIES .......................................................................................................23
USER INTERFACE .............................................................................................................................25
7.1
CONTROLS ...............................................................................................................................27
7.1.1 Buttons and Knobs.........................................................................................................27
7.1.2 Keypad...........................................................................................................................29
7.1.3 Display...........................................................................................................................30
7.1.4 Tri-Color LED ...............................................................................................................32
7.2
UNIVERSAL DEVICE CONNECTOR.....................................................................................32
EDACS OPERATION..........................................................................................................................35
8.1
CONTROLS ...............................................................................................................................35
8.1.1 Buttons and Knobs.........................................................................................................35
8.1.2 Keypad...........................................................................................................................36
8.2
DISPLAY ...................................................................................................................................38
8.3
RADIO STATUS ICONS...........................................................................................................39
8.4
TRI-COLOR LED ......................................................................................................................40
8.5
STATUS MESSAGES ...............................................................................................................40
8.6
ERROR MESSAGES .................................................................................................................41
8.7
ALERT TONES .........................................................................................................................42
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
8.8
8.9
8.10
8.11
8.12
8.13
8.14
8.15
8.16
8.17
8.18
8.19
8.20
8.21
8.22
8.23
8.24
8.25
8.26
8.27
Page
TURNING ON THE RADIO .....................................................................................................42
SYSTEM SELECTION..............................................................................................................43
GROUP/CHANNEL SELECTION............................................................................................43
MODIFY SCAN LIST ...............................................................................................................44
8.11.1 P7370 Model..................................................................................................................44
8.11.2 P7350 Model..................................................................................................................44
MENU ........................................................................................................................................44
8.12.1 Menu Item Selection Process.........................................................................................45
BACKLIGHT ADJUST .............................................................................................................47
CONTRAST ADJUST ...............................................................................................................47
DECLARING AN EMERGENCY.............................................................................................48
LOCKING/UNLOCKING KEYPAD ........................................................................................48
HIGH/LOW POWER ADJUSTMENT ......................................................................................48
8.17.1 Using the Menu Button..................................................................................................48
8.17.2 Using the Pre-Programmed Option Button....................................................................48
DIGITAL VOICE OPERATION ...............................................................................................48
8.18.1 Clear Mode ....................................................................................................................49
8.18.2 Digital Mode..................................................................................................................49
8.18.3 Private Mode..................................................................................................................49
8.18.4 Private Operation ...........................................................................................................50
SCANNING TRUNKED GROUPS...........................................................................................51
8.19.1 Turning Scan On and Off ..............................................................................................52
8.19.2 Adding Groups to a Scan List........................................................................................52
8.19.3 Deleting Groups from a Scan List .................................................................................53
8.19.4 Nuisance Delete .............................................................................................................54
SCANNING TRUNKED SYSTEMS.........................................................................................54
8.20.1 Wide Area System Scanning .........................................................................................54
8.20.2 Priority System Scan......................................................................................................54
8.20.3 ProScan..........................................................................................................................55
EMERGENCY OPERATION....................................................................................................55
8.21.1 Receiving an Emergency Call .......................................................................................55
8.21.2 Declaring an Emergency Call ........................................................................................55
INDIVIDUAL CALLS...............................................................................................................56
8.22.1 Receiving and Responding to an Individual Call ..........................................................56
8.22.2 Sending an Individual Call ............................................................................................57
8.22.3 Call Storage Lists...........................................................................................................57
TELEPHONE INTERCONNECT CALLS ................................................................................58
8.23.1 Receiving a Telephone Interconnect Call......................................................................58
8.23.2 Sending a Telephone Interconnect Call .........................................................................58
8.23.3 Dual-Tone Multi-Frequency: Overdial/Conventional Mode .........................................59
PROGRAMMABLE ENTRIES .................................................................................................60
8.24.1 Pre-Storing Individual and Telephone Interconnect Calls from the Keypad.................60
STATUS/MESSAGE OPERATION..........................................................................................61
8.25.1 Status Operation ............................................................................................................61
8.25.2 Message Operation ........................................................................................................62
DYNAMIC REGROUP OPERATION ......................................................................................62
8.26.1 Emergency Operation ....................................................................................................62
MACRO KEY OPERATION.....................................................................................................62
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
8.28
Page
PORTABLE DATA....................................................................................................................62
8.28.1 Displays .........................................................................................................................63
8.28.2 DATA OFF Operation...................................................................................................63
8.28.3 DATA ON Operation ....................................................................................................63
8.28.4 Exiting Data Calls..........................................................................................................63
8.28.5 Scan Lockout Mode.......................................................................................................63
8.28.6 Data Lockout Mode .......................................................................................................64
OPENSKY OPERATION....................................................................................................................67
9.1
CONTROLS ...............................................................................................................................67
9.1.1 Buttons and Knobs.........................................................................................................67
9.1.2 Keypad...........................................................................................................................68
9.2
RADIO STATUS ICONS...........................................................................................................69
9.3
TRI-COLOR LED ......................................................................................................................70
9.4
LOG IN TO THE NETWORK...................................................................................................70
9.5
LOG OFF THE NETWORK ......................................................................................................71
9.6
PERSONALITY .........................................................................................................................71
9.6.1 Profiles...........................................................................................................................71
9.6.2 Talk Groups ...................................................................................................................72
9.7
OPENSKY DISPLAY OVERVIEW..........................................................................................72
9.7.1 Display’s Top Line ........................................................................................................72
9.7.2 Display’s Second Line...................................................................................................72
9.7.3 Dwell Display ................................................................................................................72
9.8
ALERT TONES .........................................................................................................................73
9.9
BASIC MENU STRUCTURE ...................................................................................................74
9.10 KEYPAD FUNCTION COMMANDS (P7370 ONLY).............................................................76
9.11 QUICK KEYS (P7370 ONLY) ..................................................................................................77
9.12 LOCK/UNLOCK THE KEYPAD..............................................................................................77
9.13 DUAL-TONE MULTI-FREQUENCY (P7370 ONLY) ............................................................77
9.14 CHANGING THE ACTIVE PROFILE .....................................................................................78
9.15 CHANGING THE SELECTED TALK GROUP .......................................................................78
9.16 ADJUSTING DISPLAY AND BUTTON BACKLIGHT BRIGHTNESS ................................78
9.17 STEALTH MODE......................................................................................................................78
9.17.1 Enabling Stealth Mode ..................................................................................................78
9.17.2 Disabling Stealth Mode .................................................................................................78
9.17.3 Stealth Mode using A/B Switch ....................................................................................79
9.18 ADJUSTING SIDE TONE AUDIO LEVEL .............................................................................79
9.19 CHANGE OPERATING MODE ...............................................................................................79
9.20 RECEIVING AND TRANSMITTING VOICE CALLS ...........................................................79
9.20.1 Receiving a Voice Call ..................................................................................................79
9.20.2 Transmitting a Voice Call..............................................................................................79
9.21 ADJUSTING AUDIO TREBLE LEVEL...................................................................................80
9.22 TALK GROUP LOCK OUT ......................................................................................................80
9.22.1 Lock Out a Talk Group..................................................................................................81
9.22.2 Unlock a Talk Group .....................................................................................................81
9.23 SCANNING................................................................................................................................81
9.23.1 Selecting Scan Modes....................................................................................................81
9.23.2 Checking or Changing Active Scan Mode ....................................................................82
9.23.3 Scanning Priority ...........................................................................................................82
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
9.24
9.25
9.26
9.27
9.28
9.29
9.30
Page
MAKING SELECTIVE CALLS ................................................................................................83
9.24.1 Manually Dialing a Selective Call (P7370 Only) ..........................................................83
9.24.2 Selective Call Using Speed Dial....................................................................................84
9.24.3 Accepting a Selective Call.............................................................................................84
9.24.4 Rejecting a Selective Call..............................................................................................84
9.24.5 Terminating a Selective Call .........................................................................................85
SELECTIVE ALERTS ...............................................................................................................85
9.25.1 Defining Messages.........................................................................................................85
9.25.2 Sending a Message ........................................................................................................85
9.25.3 Receiving a Message .....................................................................................................86
9.25.4 Deleting a Selective Alert Message ...............................................................................86
MAKING INTERCONNECT CALLS (P7370 ONLY).............................................................86
EMERGENCY COMMUNICATIONS .....................................................................................87
9.27.1 Declaring an Emergency Call or Alert ..........................................................................87
9.27.2 Receiving an Emergency Call .......................................................................................88
9.27.3 Dismissing an Emergency .............................................................................................88
9.27.4 Clearing an Emergency Call or Alert ............................................................................88
DYNAMIC REGROUPING ......................................................................................................89
GPS COORDINATES................................................................................................................89
V-TAC OPERATION ................................................................................................................89
9.30.1 Extended Coverage Modes (“XCOV” and “XCOV-TG”) ............................................89
9.30.2 Change Between Extended Coverage Modes................................................................90
9.30.3 Radio Limitations Using Extended Coverage Modes....................................................90
9.30.4 Use XCOV Mode ..........................................................................................................90
9.30.5 Use XCOV-TG Mode....................................................................................................91
9.30.6 Use Scene-of-Incident Mode .........................................................................................92
10 CONVENTIONAL OPERATION ......................................................................................................95
10.1 CONTROLS ...............................................................................................................................95
10.1.1 Buttons and Knobs.........................................................................................................96
10.1.2 Keypad...........................................................................................................................97
10.2 DISPLAY ...................................................................................................................................99
10.2.1 Radio Status Icons .......................................................................................................100
10.3 TRI-COLOR LED ....................................................................................................................101
10.4 STATUS MESSAGES .............................................................................................................101
10.4.1 Error Messages ............................................................................................................102
10.5 ALERT TONES........................................................................................................................102
10.6 TURNING ON THE RADIO ...................................................................................................102
10.7 SYSTEM SELECTION............................................................................................................102
10.8 GROUP/CHANNEL SELECTION..........................................................................................103
10.9 MODIFY SCAN LIST .............................................................................................................103
10.9.1 P7370 Model................................................................................................................103
10.9.2 P7350 Model................................................................................................................104
10.10 NUISANCE DELETE ..............................................................................................................104
10.11 MENU ......................................................................................................................................104
10.12 BACKLIGHT ADJUST ...........................................................................................................107
10.13 CONTRAST ADJUST .............................................................................................................107
10.14 DECLARING AN EMERGENCY...........................................................................................107
10.15 LOCKING/UNLOCKING KEYPAD ......................................................................................108
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
10.16
10.17
10.18
10.19
Page
HIGH/LOW POWER ADJUSTMENT ....................................................................................108
DIGITAL VOICE OPERATION .............................................................................................108
10.17.1 Clear Mode ..................................................................................................................108
10.17.2 Digital Mode................................................................................................................109
RECEIVING A CALL .............................................................................................................109
SENDING A CALL .................................................................................................................110
11 P25 OPERATION...............................................................................................................................113
11.1 CONTROLS .............................................................................................................................113
11.1.1 Buttons and Knobs.......................................................................................................114
11.1.2 Keypad.........................................................................................................................115
11.2 DISPLAY .................................................................................................................................117
11.3 RADIO STATUS ICONS.........................................................................................................118
11.4 TRI-COLOR LED ....................................................................................................................119
11.5 STATUS MESSAGES .............................................................................................................119
11.5.1 Error Messages ............................................................................................................120
11.6 ALERT TONES .......................................................................................................................121
11.7 TURNING ON THE RADIO ...................................................................................................121
11.8 SYSTEM SELECTION............................................................................................................121
11.8.1 GROUP/CHANNEL SELECTION.............................................................................122
11.9 MODIFY SCAN LIST .............................................................................................................122
11.9.1 P7370 Model................................................................................................................122
11.9.2 P7350 Model................................................................................................................123
11.10 MENU ......................................................................................................................................123
11.10.1 Menu Item Selection Process.......................................................................................123
11.11 BACKLIGHT ADJUST ...........................................................................................................126
11.12 CONTRAST ADJUST .............................................................................................................126
11.13 DECLARING AN EMERGENCY...........................................................................................126
11.14 LOCKING/UNLOCKING KEYPAD ......................................................................................127
11.15 HIGH/LOW POWER ADJUSTMENT ....................................................................................127
11.15.1 Using the Menu Button................................................................................................127
11.15.2 Using the Pre-Programmed Option Button..................................................................127
11.16 DIGITAL VOICE OPERATION .............................................................................................127
11.16.1 Clear Mode ..................................................................................................................127
11.16.2 Digital Mode................................................................................................................128
11.16.3 Private Mode................................................................................................................128
11.16.4 Private Operation.........................................................................................................129
11.17 SCANNING TRUNKED GROUPS.........................................................................................130
11.17.1 Turning Scan On and Off ............................................................................................130
11.17.2 Adding Groups to a Scan List......................................................................................131
11.17.3 Deleting Groups from a Scan List ...............................................................................132
11.17.4 Nuisance Delete...........................................................................................................132
11.18 SCANNING TRUNKED SYSTEMS.......................................................................................132
11.18.1 Wide Area System Scanning .......................................................................................133
11.18.2 Priority System Scan ...................................................................................................133
11.18.3 ProScan........................................................................................................................133
11.19 EMERGENCY OPERATION..................................................................................................134
11.19.1 Receiving an Emergency Call .....................................................................................134
11.19.2 Declaring an Emergency Call......................................................................................134
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
11.20
11.21
11.22
11.23
11.24
11.25
11.26
11.27
11.28
Page
INDIVIDUAL CALLS.............................................................................................................134
11.20.1 Receiving and Responding to an Individual Call ........................................................134
11.20.2 Sending an Individual Call ..........................................................................................135
11.20.3 Call Storage Lists.........................................................................................................136
TELEPHONE INTERCONNECT CALLS ..............................................................................137
11.21.1 Receiving a Telephone Interconnect Call....................................................................137
11.21.2 Sending a Telephone Interconnect Call .......................................................................137
11.21.3 Dual-Tone Multi-Frequency: Overdial/Conventional Mode .......................................138
PROGRAMMABLE ENTRIES ...............................................................................................139
11.22.1 Pre-Storing Individual and Telephone Interconnect Calls from the Keypad...............139
STATUS/MESSAGE OPERATION........................................................................................139
11.23.1 Status Operation ..........................................................................................................140
11.23.2 Message Operation ......................................................................................................140
MACRO KEY OPERATION...................................................................................................140
PORTABLE DATA..................................................................................................................141
11.25.1 Displays .......................................................................................................................141
11.25.2 DATA OFF Operation.................................................................................................141
11.25.3 DATA ON Operation ..................................................................................................141
11.25.4 Exiting Data Calls........................................................................................................142
11.25.5 Scan Lockout Mode.....................................................................................................142
11.25.6 Data Lockout Mode .....................................................................................................142
GROUP CALLS IN P25 MODE ..............................................................................................142
11.26.1 Transmitting a Group Call ...........................................................................................142
11.26.2 Receiving a Group Call ...............................................................................................143
INDIVIDUAL CALLS IN P25 MODE....................................................................................143
11.27.1 Transmitting an Individual Call...................................................................................143
11.27.2 Receiving an Individual Call .......................................................................................143
EMERGENCY GROUP CALLS IN P25 MODE ....................................................................143
11.28.1 Declaring an Emergency Group Call...........................................................................143
11.28.2 Receiving an Emergency Group Call ..........................................................................144
12 IMMERSIBLE P7300 PREVENTIVE MAINTENANCE..............................................................147
12.1 TECHNICAL ASSISTANCE – IMMERSIBLE P7300...........................................................147
13 TECHNICAL ASSISTANCE ............................................................................................................149
14 BASIC TROUBLESHOOTING........................................................................................................150
FIGURES
Figure 4-1: Removing the Battery Pack......................................................................................................... 19
Figure 4-2: Attaching the Battery Pack.......................................................................................................... 20
Figure 7-1: P7300 Portable Radio.................................................................................................................. 26
Figure 7-2: Top View..................................................................................................................................... 27
Figure 7-3: Side View .................................................................................................................................... 27
Figure 7-4: P7350 “Scan” Model Front Panel ............................................................................................... 29
Figure 7-5: P7370 “System” Model Front Panel ........................................................................................... 29
Figure 7-6: P7300 Radio Display................................................................................................................... 30
Figure 7-7: Full Cycle Battery Charge Indicator ........................................................................................... 32
Figure 7-8: Tri-Color LED............................................................................................................................. 32
Figure 7-9: P7300 15-Pin Universal Device Connector................................................................................. 33
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
Page
Figure 8-1: P7350 “Scan” Radio Front Panel ................................................................................................ 36
Figure 8-2: P7370 “System” Radio Front Panel ............................................................................................ 37
Figure 8-3: P7300 Radio Display................................................................................................................... 38
Figure 8-4: Full Cycle Battery Charge Indicator ........................................................................................... 39
Figure 8-5: Tri-Color LED............................................................................................................................. 40
Figure 8-6: Menu Display .............................................................................................................................. 44
Figure 8-7: Backlight Menu Item Selection Parameter.................................................................................. 45
Figure 8-8: Backlight Menu Display ............................................................................................................. 45
Figure 8-9: System Encryption Key Display ................................................................................................. 50
Figure 8-10: Group/Channel Encryption Key Display .................................................................................. 50
Figure 8-11: Calls Received Lists.................................................................................................................. 56
Figure 8-12: WHC Individual Call Display ................................................................................................... 57
Figure 8-13: Calls Received and Personality Lists ........................................................................................ 58
Figure 9-1: Full Cycle Battery Charge Indicator ........................................................................................... 69
Figure 9-2: Tri-Color LED............................................................................................................................. 70
Figure 9-3: Personality Structure Example .................................................................................................... 72
Figure 10-1: Top View................................................................................................................................... 95
Figure 10-2: Side View .................................................................................................................................. 95
Figure 10-3: P7350 “Scan” Radio Front Panel .............................................................................................. 97
Figure 10-4: P7370 “System” Radio Front Panel .......................................................................................... 98
Figure 10-5: P7300 Radio Display................................................................................................................. 99
Figure 10-6: Battery Charge Icons (Full Cycle) .......................................................................................... 100
Figure 10-7: Tri-Color LED......................................................................................................................... 101
Figure 10-8: Menu Display .......................................................................................................................... 104
Figure 10-9: Backlight Menu Item Parameter ............................................................................................. 105
Figure 10-10: Backlight Menu Display ....................................................................................................... 105
Figure 11-1: Top View................................................................................................................................. 113
Figure 11-2: Side View ................................................................................................................................ 113
Figure 11-3: P7350 “Scan” Radio Front Panel ............................................................................................ 115
Figure 11-4: P7370 “System” Radio Front Panel ........................................................................................ 116
Figure 11-5: P7300 Radio Display............................................................................................................... 117
Figure 11-6: Full Cycle Battery Charge Indicator ....................................................................................... 119
Figure 11-7: Tri-Color LED......................................................................................................................... 119
Figure 11-8: Menu Display .......................................................................................................................... 123
Figure 11-9: Backlight Menu Item Selection Parameter.............................................................................. 124
Figure 11-10: Backlight Menu Display ....................................................................................................... 124
Figure 11-11: System Encryption Key Display ........................................................................................... 129
Figure 11-12: Group/Channel Encryption Key Display .............................................................................. 129
Figure 11-13: Calls Received Lists.............................................................................................................. 135
Figure 11-14: WHC Individual Call Display ............................................................................................... 135
Figure 11-15: Calls Received and Personality Lists .................................................................................... 136
Figure 12-1: Labels ...................................................................................................................................... 147
TABLES
Table 2-1: RF Exposure Compliance Testing Distances ............................................................................... 14
Table 6-1: Options and Accessories............................................................................................................... 23
Table 7-1: P7300 Front Keypad Functions .................................................................................................... 29
Table 7-2: Status Icons Descriptions ............................................................................................................. 31
Table 8-1: P7350 Keypad Functions.............................................................................................................. 36
MM-013994-001, Rev. Ap1
TABLE OF CONTENTS
Page
Table 8-2: P7370 Keypad Functions.............................................................................................................. 37
Table 8-3: EDACS Icon Descriptions............................................................................................................ 39
Table 8-4: Alert Tones ................................................................................................................................... 42
Table 8-5: Menu Item Information ................................................................................................................ 46
Table 8-6: Information Display...................................................................................................................... 47
Table 8-7: Transmit/Receive Mode Compatibility for Digital Voice Operation ........................................... 51
Table 9-1: Keypad Functions ......................................................................................................................... 68
Table 9-2: Status Icons Descriptions.............................................................................................................. 69
Table 9-3: Alert Tones ................................................................................................................................... 73
Table 9-4: Basic P7300 OpenSky Menu Structure ........................................................................................ 74
Table 9-5: Keypad Function Commands ....................................................................................................... 76
Table 9-6: Quick Key Sequence .................................................................................................................... 77
Table 9-7: Scan Modes .................................................................................................................................. 82
Table 9-8: Status of Selective Alert Messages............................................................................................... 85
Table 9-9: Emergency Calls vs. Emergency Alerts ....................................................................................... 87
Table 9-10: Band Definitions......................................................................................................................... 93
Table 10-1: Status Icon Descriptions ........................................................................................................... 100
Table 10-2: Alert Tones ............................................................................................................................... 102
Table 10-3: Menu Item Information ............................................................................................................ 106
Table 10-4: Information Display.................................................................................................................. 107
Table 10-5: Transmit/Receive Mode Compatibility for Digital Voice Operation ....................................... 109
Table 11-1: P7350 Keypad Functions.......................................................................................................... 115
Table 11-2: P7370 “System” Keypad Functions ......................................................................................... 116
Table 11-3: Radio Status Icon Descriptions................................................................................................. 118
Table 11-4: Alert Tones ............................................................................................................................... 121
Table 11-5: Menu Item Information ............................................................................................................ 125
Table 11-6: Information Display.................................................................................................................. 126
Table 11-7: Transmit/Receive Mode Compatibility for Digital Voice Operation ....................................... 130
Table 14-1: Troubleshooting........................................................................................................................ 150
10
MM-013994-001, Rev. Ap1
SAFETY SECTION
11
MM-013994-001, Rev. Ap1
SAFETY CONVENTIONS
The following conventions are used throughout this manual to alert the user to general safety precautions
that must be observed during all phases of operation, service, and repair of this product. Failure to comply
with these precautions or with specific warning elsewhere in this manual violates safety standards of
design, manufacture, and intended use of the product. Harris Corporation assumes no liability for the
customer’s failure to comply with these standards.
The WARNING symbol calls attention to a procedure, practice, or the like, which, if
not correctly performed or adhered to, could result in personal injury. Do not
proceed beyond a WARNING symbol until the conditions identified are fully
understood or met.
CAUTION
The CAUTION symbol calls attention to an operating procedure, practice, or the like,
which, if not performed correctly or adhered to, could result in damage to the equipment
or severely degrade the equipment performance.
The NOTE symbol calls attention to supplemental information, which may improve
system performance or clarify a process or procedure.
The ESD symbol calls attention to procedures, practices, or the like, which could expose
equipment to the effects of Electro-Static Discharge. Proper precautions must be taken to
prevent ESD when handling circuit modules.
WARNING - The electrical hazard symbol indicates there is an electrical hazard
present.
12
MM-013994-001, Rev. Ap1
SAFETY TRAINING INFORMATION
The Harris P7300 portable radio generates RF electromagnetic energy during
transmit mode. This radio is designed for and classified as “Occupational Use
Only,” meaning it must be used only during the course of employment by
individuals aware of the hazards and the ways to minimize such hazards. This
radio is NOT intended for use by the “General Population” in an uncontrolled
environment.
The P7300 portable radio has been tested and complies with the FCC RF exposure limits for
“Occupational Use Only.” In addition, this Harris radio complies with the following Standards and
Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for
exposure to humans:
•
FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compliance with FCC Guidelines for
Human Exposure to Radio Frequency Electromagnetic Fields.
•
American National Standards Institute (C95.1 – 1992), IEEE Standard for Safety Levels with Respect
to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.
•
American National Standards Institute (C95.3 – 1992), IEEE Recommended Practice for the
Measurement of Potentially Hazardous Electromagnetic Fields – RF and Microwave.
2.1
RF EXPOSURE GUIDELINES
To ensure that exposure to RF electromagnetic energy is within the FCC allowable
limits for occupational use, always adhere to the following guidelines:
CAUTION
•
DO NOT operate the radio without a proper antenna attached, as this may damage the radio and may
also cause the FCC RF exposure limits to be exceeded. A proper antenna is the antenna supplied with
this radio by Harris or an antenna specifically authorized by Harris for use with this radio. (Refer to
Table 6-1.)
•
DO NOT transmit for more than 50% of total radio use time (“50% duty cycle”). Transmitting more
than 50% of the time can cause FCC RF exposure compliance requirements to be exceeded. The radio
is transmitting when the “TX” indicator appears in the display. The radio will transmit by pressing the
“PTT” (Push-To-Talk) button.
•
Always transmit using low power when possible. In addition to conserving battery charge, low power
can reduce RF exposure.
•
ALWAYS use Harris authorized accessories (antennas, batteries, belt clips, speaker/mics, etc). Use of
unauthorized accessories may cause the FCC Occupational/Controlled Exposure RF compliance
requirements to be exceeded. (Refer to Table 2-1.)
13
MM-013994-001, Rev. Ap1
•
As noted in Table 2-1, ALWAYS keep the device and its antenna AT LEAST 1.1 cm (0.43 inches)
from the body and at least 2.5 cm (1.0 inch) from the face when transmitting to ensure FCC RF
exposure compliance requirements are not exceeded. However, to provide the best sound quality to
the recipients of your transmission, Harris recommends you hold the microphone at least 5 cm (2
inches) from mouth, and slightly off to one side.
Table 2-1: RF Exposure Compliance Testing Distances
TESTED DISTANCES
(worst case scenario)
RADIO FREQUENCY
Body
Face
450-512 MHz
1.1 cm
2.5 cm
700/800 MHz
1.1 cm
2.5 cm
The information in this section provides the information needed to make the user aware of RF exposure,
and what to do to assure that this radio operates within the FCC RF exposure limits of this radio.
2.2
ELECTROMAGNETIC INTERFERENCE/COMPATIBILITY
During transmissions, this Harris radio generates RF energy that can possibly cause interference with
other devices or systems. To avoid such interference, turn off the radio in areas where signs are posted to
do so. DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as
hospitals, aircraft, and blasting sites.
14
MM-013994-001, Rev. Ap1
OPERATING TIPS
Antenna location and condition are important when operating a portable radio. Operating the radio in low
lying areas or terrain, under power lines or bridges, inside of a vehicle or in a metal framed building can
severely reduce the range of the unit. Mountains can also reduce the range of the unit.
In areas where transmission or reception is poor, some improvement may be obtained by ensuring that the
antenna is vertical. Moving a few yards in another direction or moving to a higher elevation may also
improve communications. Vehicular operation can be aided with the use of an externally mounted
antenna.
Battery condition is another important factor in the trouble free operation of a portable radio. Always
properly charge the batteries.
3.1
EFFICIENT RADIO OPERATION
Keep the antenna in a vertical position when receiving or transmitting a message.
Do not hold the antenna when receiving a message and, especially, do not hold when transmitting a
message.
Do NOT hold onto the antenna when the radio is powered on!
3.1.1
Antenna Care and Replacement
Do not use the portable radio with a damaged or missing antenna. A minor burn
may result if a damaged antenna comes into contact with the skin. Replace a
damaged antenna immediately. Operating a portable radio with the antenna missing
could cause personal injury, damage the radio, and may violate FCC regulations.
Use only the supplied or approved antenna. Unauthorized antennas, modifications,
or attachments could cause damage to the radio unit and may violate FCC
regulations. (Refer to Table 6-1.)
3.1.2
CAUTION
Electronic Devices
RF energy from portable radios may affect some electronic equipment. Most modern
electronic equipment in cars, hospitals, homes, etc. is shielded from RF energy. However,
in areas in which you are instructed to turn off two-way radio equipment, always observe
the rules. If in doubt, turn it off!
15
MM-013994-001, Rev. Ap1
3.1.3
3.1.4
Aircraft
•
Always turn off a portable radio before boarding any aircraft!
•
Use it on the ground only with crew permission.
•
DO NOT use while in-flight!!
Electric Blasting Caps
To prevent accidental detonation of electric blasting caps, DO NOT use two-way
radios within 1000 feet of blasting operations. Always obey the "Turn Off Two-Way
Radios" signs posted where electric blasting caps are being used. (OSHA Standard:
1926.900)
3.1.5
Potentially Explosive Atmospheres
Areas with potentially explosive atmospheres are often, but not always, clearly
marked. These may be fuelling areas, such as gas stations, fuel or chemical transfer
or storage facilities, and areas where the air contains chemicals or particles, such as
grain, dust, or metal powders.
Sparks in such areas could cause an explosion or fire resulting in bodily injury or
even death.
Turn OFF two-way radios when in any area with a potentially explosive atmosphere.
It is rare, but not impossible that a radio or its accessories could generate sparks.
16
MM-013994-001, Rev. Ap1
BATTERIES
The P7300 series portable radios use rechargeable, recyclable Nickel Cadmium (NiCd), Nickel Metal
Hydride (NiMH), or Lithium Ion (Li Ion) batteries. Please read carefully, the battery information
provided, to maximize the useful life of each type of battery.
Do not disassemble or modify Lithium Ion battery packs. The Lithium Ion battery
packs are equipped with built-in safety and protection features. Should these
features be disabled or tampered with in any way, the battery pack can leak acid,
overheat, emit smoke, burst, and/or, ignite.
If the battery is ruptured or is leaking electrolyte that results in skin or eye contact
with the electrolyte, immediately flush the affected area with water. If the battery
electrolyte gets in the eyes, flush with water for 15 minutes and consult a physician
immediately.
4.1
CONDITIONING BATTERY PACKS
4.1.1
Conditioning NiMH Battery Packs
Condition a new NiMH battery before putting into use. This also applies to rechargeable NiMH batteries
that have been stored for long periods (weeks, months, or longer). Conditioning requires fully charging
and fully discharging the battery three (3) times using the tri-chemistry charger. The first time the battery
is put into the charger, this unit will condition Nickel-based battery packs by automatically charging and
discharging (cycling) the battery. Refer to the appropriate charger manual for details.
Failure to properly condition NiMH battery packs before initial use will result in
shortened performance by the battery.
CAUTION
4.1.2
Conditioning NiCd Battery Packs
A new NiCd battery does not require conditioning before use. However, Harris recommends periodically
conditioning NiCd batteries to avoid the memory effect which results when a NiCd battery is repeatedly
charged and not fully discharged, further resulting in a lower voltage and a lower capacity. Fortunately,
both nominal voltage and capacity are restored through battery conditioning.
Conditioning requires fully charging and fully discharging the battery three (3) times using the trichemistry charger. The first time the battery is put into the charger, this unit will condition Nickel-based
battery packs by automatically charging and discharging (cycling) the battery. Refer to the appropriate
charger manual for details.
17
MM-013994-001, Rev. Ap1
Always use Harris authorized chargers and conditioners. Use of unauthorized chargers
and conditioners may void the warranty.
CAUTION
4.1.3
Additional Information
For more information regarding the proper care of portable radio batteries or establishing a battery
maintenance program, refer to ECR-7367 which may be ordered by calling toll free 1-800-368-3277, then
select option 7.
4.2
CHARGING BATTERY PACKS
Battery chargers are available from Harris with nominal charge times. Combinations include single and
multi-position charge units.
Harris chargers are specifically designed for charging nickel-based and lithium ion battery packs. The
chargers are chemistry-specific for the battery packs and automatically adjust the charging profiles
accordingly. Refer to the appropriate charger manual for specific operating instructions.
4.2.1
Charging Guidelines
Observe the following guidelines when charging a battery pack:
•
Avoid high temperature during charging.
•
Discontinue use if the charger is overheating.
•
Only charge Harris battery packs using a charger approved for use by Harris.
•
Do not leave batteries in the charger indefinitely. For best results, leave the battery in the charger for
two to six hours after the Green Ready LED comes on. Then place the battery pack into service and
fully discharge (as indicated by the radio low battery warning) before re-charging.
If any faults are encountered while charging the battery pack, consult the charger’s manual to determine
the cause and possible corrective action.
4.3
BATTERY PACK USAGE
Both Nickel-based and Lithium ion batteries vary in capacity and life cycle. For instance, NiCd batteries
have a longer life cycle than NiMH batteries whereas NiMH batteries have a larger capacity. However,
both Nickel-based and Lithium ion type batteries require basic usage guidelines be followed in order to
optimize the battery runtime or shift life.
4.3.1
Usage Guidelines
The following guidelines will help optimize the battery runtime or shift life:
18
•
Ensure Nickel-based battery packs are fully discharged (as indicated by the radio low battery
warning) before re-charging. Full discharge is not required for Lithium Ion battery packs.
•
Periodically condition Nickel-based battery packs. The frequency should be determined based on
usage patterns (refer to ECR-7367). If the battery is fully discharged (to radio Low Battery warning)
during routine use, the frequency of conditioning may be reduced. Lithium Ion batteries do not suffer
from memory-effect and therefore do not require conditioning.
MM-013994-001, Rev. Ap1
Do not leave any Harris rechargeable batteries in a charger for more than a few days.
4.4
CHANGING THE BATTERY PACK
4.4.1
Removing the Battery Pack
Make sure the power to the radio is turned OFF.
CAUTION
Although the P7300 has been designed to tolerate changing the battery pack without
turning power off, Harris recommends turning the radio off before changing battery packs
to ensure safety and best operation.
1. Press or pull both latches on either side of the battery pack  toward the bottom of the radio
simultaneously.
2. Pull the battery  away from the radio.
3. Remove the battery pack from the radio.
Figure 4-1: Removing the Battery Pack
19
MM-013994-001, Rev. Ap1
4.4.2
Attaching the Battery Pack
Make sure the power to the radio is turned OFF.
1. Align the tabs at each side on the bottom of the battery pack with the slots at the bottom of the battery
cavity .
2. Push the top of the battery pack  down until the latches click to attach the battery to the radio.
3. Tug gently to verify that the latches are secure and the battery pack is properly attached to the radio.
Figure 4-2: Attaching the Battery Pack
4.5
BATTERY DISPOSAL
In no instance should a battery be incinerated. Disposing of a battery by burning will
cause an explosion.
CAUTION
RECHARGEABLE BATTERY PACK DISPOSAL – The product you have
purchased contains a rechargeable battery. The battery is recyclable. At the end of its
useful life, under various state and local laws, it may be illegal to dispose of this
battery into the municipal waste stream. Check with your local solid waste officials for
details in your area for recycling options or proper disposal. Canadian and U.S. users
may call Toll Free 1-800-8-BATTERY® for information and/or procedures for
returning rechargeable batteries in your locality.
20
MM-013994-001, Rev. Ap1
PRODUCT INFORMATION
21
MM-013994-001, Rev. Ap1
INTRODUCTION
The P7300 series portable radio is available in two models: the P7350 Scan model with a limited 6-button
front-mounted keypad and the P7370 System model with a 15-button DTMF front-mounted keypad. The
UHF P7300 portable radio delivers end-to-end encrypted digital voice and IP data communications. It is
designed to support multiple operating modes including:
•
EDACS® (Enhanced Digital Access Communications System) or ProVoice™ Trunked mode
•
P25 Trunked Mode
•
P25 Digital Conventional Mode
•
Conventional Analog mode
The P7300 portables can include all of these modes or just one. Additional modes of operation can be
added with software updates.
The P7300 supports a full range of advanced digital trunking features, including voice group calls,
priority scanning, emergency calls, late call entry, and dynamic reconfiguration. It performs autonomous
roaming for wide area applications. High quality voice coding and robust audio components assure
speech clarity.
In the trunked modes, the user selects a communications “operating” system (i.e., EDACS, ProVoice, or
P25) and group. While communicating in a trunked mode, channel selection is transparent to the user and
is controlled via digital communication with the system controller (e.g., a CSD in an EDACS system).
This provides advanced programmable features and fast access to communication channels.
In Conventional Analog mode, the user selects a channel and communicates directly on that channel. A
channel is a transmit/receive radio frequency pair.
The exact operation of the radio will depend on the operating mode, the radio’s programming, and the
particular radio system. Most features described in this manual can be enabled through programming.
Consult your System Administrator for the particular features programmed into your P7300. Then refer
to the corresponding section(s) within this manual for feature and operation information.
5.1
WATER RESISTANCE
The P7300 series portable radios operate reliably even under adverse conditions. These radios meet MILSTD-810F specifications for wind driven rain, humidity, and salt fog.
22
MM-013994-001, Rev. Ap1
OPTIONS AND ACCESSORIES
Table 6-1 lists the Options and Accessories tested for use with the P7300 series portable radios.
Refer to the maintenance manual or to Harris Products and Services Catalog for a complete list of options
and accessories, including those items that do not adversely affect the RF energy exposure.
Always use Harris authorized accessories (antennas, batteries, belt clips,
speaker/mics, etc). Use of unauthorized accessories may cause the FCC
Occupational/Controlled Exposure RF compliance requirements to be exceeded.
(Refer to Table 2-1.)
Always use the correct options and accessories (battery, antenna, speaker/mic, etc.) for the
radio. Intrinsically safe options must be used with intrinsically safe radios. (Refer to Table
6-1.)
CAUTION
Table 6-1: Options and Accessories
DESCRIPTION
PART NUMBER
ANTENNAS
Helical Stub 470-512 MHz
KRE 101 1219/14
¼ λ Whip 440-512 MHz
KRE 101 1223/12
BATTERIES (IMMERSION-RATED)
7.5V Nickel Cadmium (NiCd) Battery, Immersible, non-
7.5V Nickel Cadmium (NiCd) Battery, Immersible, 
7.5V Nickel Metal Hydride (NiMH) Battery, Immersible, non-
7.5V Nickel Metal Hydride (NiMH) Battery, Immersible, 
7.5V Lithium Ion (Li Ion) Battery, Immersible, non-
7.5V Lithium Ion (Li Ion) Battery, Immersible, 
MISCELLANEOUS ACCESSORIES
Speaker Mic without Antenna (cc) provision, 
Speaker Mic with Antenna (cc) provision, 
Earphone for Speaker Mic 
DROP SHIP AUDIO ACCESSORIES
Earphone Kit, Black
Earphone Kit, Beige
2-Wire Kit, Palm Mic, Black
2-Wire Kit, Palm Mic, Beige
3-Wire Kit, Mini-Lapel Mic, Black
3-Wire Kit, Mini-Lapel Mic, Beige
Explorer Headset with PTT
Lightweight Headset Single Speaker with PTT
Breeze Headset with PTT
Headset, Heavy Duty, N/C Behind-the-Head, with PTT
Ranger Headset with PTT
Skull Mic with Body PTT and Earcup
Headset, Heavy Duty, N/C Over-the-Head, with PTT
Throat Mic with Acoustic Tube and Body PTT
BT-023406-001
BT-023406-002
BT-023406-003
BT-023406-004
BT-023406-005
BT-023406-006
MC-023933-001
MC-023933-002
LS103239V1
EA-009580-001
EA-009580-002
EA-009580-003
EA-009580-004
EA-009580-005
EA-009580-006
EA-009580-007
EA-009580-008
EA-009580-009
EA-009580-010
EA-009580-011
EA-009580-012
EA-009580-013
EA-009580-014
23
MM-013994-001, Rev. Ap1
DESCRIPTION
Throat Mic with Acoustic Tube, Body PTT, and Ring PTT
Breeze Headset with PTT and Pigtail Jack
Hurricane Headset with PTT
Hurricane Headset with PTT and Pigtail Jack
CARRYING CASE ACCESSORIES
P7300 Black Nylon Case with Belt Loop Kit, consists of:
P7300 Black Nylon Case with Retaining Strap
and Leather Belt Loop
P7300 Orange Nylon Case with Belt Loop Kit, consists of:
P7300 Orange Nylon Case with Retaining Strap
and Leather Belt Loop
P7300 Leather Case with Belt Loop Kit, consists of:
P7300 Leather Case with Retaining Strap
(w/o Shoulder Strap D-Rings), Swivel Mount
and Leather Belt Loop
P7300 Leather Case with Shoulder Strap Kit, consists of:
P7300 Leather Case with Retaining Strap D-Rings
with Retaining Strap, Swivel Mount
Shoulder Strap
Short Leather Retaining Strap (for use with Shoulder Strap application)
Swivel Mount and Belt Loop
Metal Belt Clip (standard)
Metal Belt Clip (alternate)
“T” Strap Holder
24
PART NUMBER
EA-009580-015
EA-009580-016
EA-009580-017
EA-009580-018
Kit: KT-016201-001, incl:
FM-016199-001
CC-014527
Kit: KT-016201-002, incl:
FM-016199-002
CC-014527
Kit: KT-016201-003, incl:
FM-016199-003
KRY 101 1608/2
CC-014527
Kit: KT-016201-004, incl:
FM-016199-004
KRY 101 1608/2
CC-014524-001
CC-014524-002
KRY 101 1608/2
KRY 101 1609/1
CC23894
CC-011318
KRY 101 1656/1
MM-013994-001, Rev. Ap1
USER INTERFACE
This section describes the primary user interface; the buttons, knob controls, indicators, and display.
25
MM-013994-001, Rev. Ap1
Figure 7-1: P7300 Portable Radio
26
MM-013994-001, Rev. Ap1
7.1
CONTROLS
7.1.1
Buttons and Knobs
The P7300 portable radios feature two rotary control knobs, an emergency button, and a dual-position
A/B switch located on the top of the radio (Figure 7-2). The Push-To-Talk (PTT) button and two option
buttons are located on the side (Figure 7-3).
Figure 7-2: Top View
Figure 7-3: Side View
The functions of the button and knob controls vary depending on the mode of operation. The primary
functions of the button and knob controls when in the EDACS mode of operation are listed in the
following paragraphs. The functions while in other modes are discussed in the specific sections.
27
MM-013994-001, Rev. Ap1
POWER ON/OFF-VOLUME
CONTROL KNOB
Applies power to the radio and adjusts audio volume.
Rotating the control clockwise applies power to the radio. A single
alert tone (if enabled through programming) indicates the radio is
operational.
Rotating the control clockwise increases the volume level. Minimum
volume levels may be programmed into the radio to prevent missed
calls due to a low volume setting. While adjusting the volume, the
display will momentarily indicate the volume level (i.e., VOL=31). The
volume range is from a minimum programmed level of zero (displayed
as OFF in the display) up to 40, which is the loudest level.
SYSTEM/GROUP/CHANNEL
CONTROL KNOB
Used to select groups/channels. This is a 16-position rotary knob.
Note: A mechanical stop, used to limit the number of accessible
positions, is shipped with the radio but must be installed. To install the
mechanical stop, remove the System/Group/Channel control knob,
loosen the set screw on the System/Group/Channel control knob metal
base (using a 1.27 mm hex wrench), and remove the
System/Group/Channel control knob metal base. Replace the 16
channel ring with the channel stop ring located at the desired channel.
Re-install the System/Group/Channel control knob metal base, tighten
the set screw, and re-install the System/Group/Channel control knob.
EMERGENCY/HOME BUTTON
Automatically selects the pre-programmed Group/System by pressing
and holding for a programmed duration. It can also be used to declare
an emergency by pressing and holding for a programmed duration. The
button must be pre-programmed for either operation, but not both.
PUSH-TO-TALK (PTT) BUTTON
The PTT button must be pressed before voice transmission begins.
OPTION BUTTON
Activates one of a number of programmable software options selected
during PC programming. Programmable options include hi/low power
settings, keypad lock, LCD contrast, LCD and keypad back lighting.
CLEAR/MONITOR BUTTON
Exits the current operation (removing all displays associated with it)
and returns the radio to the selected talk group. Terminates individual
and telephone interconnect calls.
(OPTION BUTTON 2)
28
MM-013994-001, Rev. Ap1
7.1.2
Keypad
The front mounted keypad of the P7350 “Scan” model has six buttons and P7370 “System” model has 15
buttons. Refer to Figure 7-4 and Figure 7-5, respectively.
Figure 7-4: P7350 “Scan” Model Front Panel
Figure 7-5: P7370 “System” Model Front Panel
Alpha-numeric character entry is the secondary function of most of the P7300 keypad keys in the EDACS
mode of operation. In addition, the
(*) and
(#) keys are also available. The primary and
secondary functions of each key, where applicable, are described in Table 7-1 and the following section.
Table 7-1: P7300 Front Keypad Functions
KEY
FUNCTION
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within the menu. This is similar to an “Enter”
key.
Primary Function: Allows the user to scroll through available systems, groups, or channels,
depending on personality programming.
Secondary Function: Changes the selection for an item within a list.
(P7350 only)
(P7350 only)
(P7350 only)
In EDACS and Conventional Analog modes, Adds/Deletes selected groups or channels from
SCAN list of the currently selected system.
In EDACS and Conventional Analog modes, toggles SCAN operation ON and OFF.
In EDACS and Conventional Analog modes, activates one of any programmable software
options selected during the PC programming, including: high/low TX power and talkaround.
Primary function: Selects a specific system. If the rotary knob is used to select the system
key is used to select
and more than 16 systems are programmed in the radio, the
additional banks (groupings) of systems.
Primary function: Selects a specific group.
Primary function: Turns the Scan operation ON and OFF.
Primary function: Enables or disables Private Mode for the system/group/channel displayed.
29
MM-013994-001, Rev. Ap1
KEY
FUNCTION
Primary function: Adds groups or channels from the currently selected system to the Scan
list.
Primary function: Status key. Access to the status list (0-9). The Status key permits the
transmission of a pre-programmed status message to an EDACS site.
Primary function: Message key. Access to the message list (0-9). The Message key permits
the transmission of a pre-programmed message to an EDACS site.
Primary function: Deletes selected groups or channels of the currently selected system from
the Scan list.
Secondary function: In EDACS mode the secondary function of these keys is much as a
typical DTMF telephone pad 0-9, *, and # keys; and are used to place telephone
interconnect and individual (unit-to-unit) calls. (See individual listings for primary
functions.)
(P7370 Only)
(P7370 Only)
(P7370 Only)
7.1.3
Primary function: In EDACS mode, initiates telephone interconnect calls.
Primary function: In EDACS mode, initiates individual, unit-to-unit calls.
Display
The P7300 display is made up of 3 lines. Lines 1 and 2 contain twelve alpha-numeric character blocks
each. The 3rd line also contains twelve blocks, each used to display radio status icons. If programmed, the
display backlighting will illuminate upon power up or when radio controls are operated. Specific display
characteristics will be discussed in following sub-sections.
Figure 7-6: P7300 Radio Display
30
MM-013994-001, Rev. Ap1
7.1.3.1
Radio Status Icons
Status Icons represent various operating characteristics of the radio and appear on the third line of the
display. Each of the icons will be discussed in further detail in the corresponding modes of operation;
EDACS and Conventional icons will be discussed in the EDACS or Conventional Operation sections, and
P25 icons will be discussed in the P25 Operation section.
Table 7-2: Status Icons Descriptions
STATUS ICON DESCRIPTIONS
EDACS, CONVENTIONAL, AND P25 ICONS
st
Steady – during all radio transmissions. Appears in the 1 position of the display.
nd
Steady – “Busy” transmitting or receiving. Appears in the 2 position of the display.
Flashing – call queued.
rd
Steady – T99 Mode enabled. Appears in the 3 position of the display.
Steady – Channel Guard enabled. Appears in the 4th position of the display.
If icon is not visible – Channel Guard is disabled.
™
th
Steady – trunked system in Failsoft mode. Appears in the 4 position of the display.
th
Steady – transmit at low power. Appears in the 5 position of the display.
If icon is not visible – transmit at high power.
th
Steady – transmit in encrypt mode. Appears in the 6 position of the display.
Flashing – receiving an encrypted call.
Steady – Indicates the current channel is set up as a Project 25 (P25) channel. Appears in the
th
th
7 and 8 positions of the display.
Steady – Indicates the current channel is set up as a ProVoice channel. Appears in the 7
position of the display.
Steady – Indicates the current channel is set up as an analog channel. Appears in the 7
position of the display.
th
th
th
Animated (rotates clockwise) – scan mode enabled. Appears in the 9 position of the display.
If icon is not visible – scan is disabled.
th
Steady – priority 1 group or channel. Appears in the 10 position of the display.
th
Steady – priority 2 group or channel. Appears in the 10 position of the display.
th
Steady – group or channel in scan list. Appears in the 10 position of the display.
th
Steady – special call mode (individual or telephone). Appears in the 11 position of the
display.
th
Steady – battery charge indicators. Appear in the 12 position of the display.
Flashing – Low battery indicator.
31
MM-013994-001, Rev. Ap1
Figure 7-7: Full Cycle Battery Charge Indicator
The battery charge indicators illustrate approximate level only, based on battery voltage. Refer to Figure
7-7.
Figure 7-8: Tri-Color LED
7.1.4
Tri-Color LED
The Tri-Color LED changes color to indicate radio status and is visible from both the front and top of the
radio (see Figure 7-2). In addition, the mode of operation may also help determine what the color of the
LED represents.
In EDACS, Conventional, or P25 modes
7.2
Green:
Receiving
Red:
Transmitting Unencrypted
Orange:
Transmitting Encrypted
UNIVERSAL DEVICE CONNECTOR
The Universal Device Connector (UDC) provides connections for external accessories such as a headset,
a speaker-microphone, audio test box, audio test cables, and programming cables. The UDC is located on
the right side of the radio, opposite the PTT Button. The UDC facilitates programming and testing the
radio. The UDC pins perform different functions depending on the accessory attached to the UDC.
32
MM-013994-001, Rev. Ap1
Figure 7-9: P7300 15-Pin Universal Device Connector
33
MM-013994-001, Rev. Ap1
EDACS OPERATION
34
MM-013994-001, Rev. Ap1
8.1
EDACS OPERATION
CONTROLS
The radio features two rotary control knobs and an emergency button mounted on the top of the radio.
Push-To-Talk and option buttons are mounted on the side. The front mounted keypad has six buttons on
the P7350 Scan model and 15 buttons on the P7370 System Radio.
8.1.1
Buttons and Knobs
This section describes the primary function of the button and knob controls (see Figure 7-2 and Figure
7-3). Other functions associated with these controls are detailed in later sections.
POWER ON/OFF-VOLUME
CONTROL KNOB
Applies power to and adjusts the receiver’s volume. Rotating the
control clockwise applies power to the radio. A single alert tone (if
enabled through programming) indicates the radio is operational.
Rotating the control clockwise increases the volume level. Minimum
volume levels may be programmed into the radio to prevent missed
calls due to a low volume setting. While adjusting the volume the
display will momentarily indicate the volume level (i.e., VOL=31). The
volume range is from a minimum programmed level of zero (displayed
as OFF in the display) up to 40, which is the loudest level.
SYSTEM/GROUP/CHANNEL
CONTROL KNOB
Selects systems or group/channels (depending on programming). This
is a 16-position rotary knob.
Note: A mechanical stop, which can limit the positions accessed, is
shipped with the radio but must be installed. To install the mechanical
stop, remove the System/Group/Channel control knob, loosen the set
screw on the System/Group/Channel control knob metal base (using a
1.27 mm hex wrench), and remove the System/Group/Channel control
knob metal base. Replace the 16 channel ring with the channel stop ring
located at the desired channel. Reinstall the System/Group/Channel
control knob metal base, tighten the set screw, and reinstall the
System/Group/Channel control knob.
EMERGENCY/HOME BUTTON Automatically selects the pre-programmed Group/System by pressing
and holding for a programmed duration. It can also be used to declare
an emergency by pressing and holding for a programmed duration. The
button must be pre-programmed for either operation, but not both.
PTT BUTTON
PTT must be pressed before voice transmission begins. In trunked mode
the radio’s ID is transmitted upon depression of the PTT button.
OPTION BUTTON
Activates one of a number of programmable software options selected
during PC programming. Programmable options include hi/low power
settings, keypad lock, LCD contrast, LCD and keypad back lighting.
CLEAR/MONITOR BUTTON
Exits the current operation (removing all displays associated with it)
and returns the radio to the selected talk group. Terminates individual
and telephone interconnect calls.
OPTION BUTTON 2
35
MM-013994-001, Rev. Ap1
8.1.2
Keypad
The keys on the keypad have special functions and are labeled using a symbol or abbreviated word
describing its primary function. Alpha-numeric entry is a secondary function of the keys. Each key is
described in the following subsections.
Figure 8-1: P7350 “Scan” Radio Front Panel
Table 8-1: P7350 Keypad Functions
KEY
FUNCTION
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within the menu. This is similar to an “Enter” key.
Scrolls thru available menu items.
(P7350 only)
(P7350 only)
(P7350 only)
36
Activates one of any programmable software options selected during the PC programming, including:
high/low TX power and talkaround.
Toggles SCAN operation ON and OFF.
Adds/Deletes selected groups or channels from SCAN list of the currently selected system.
MM-013994-001, Rev. Ap1
Figure 8-2: P7370 “System” Radio Front Panel
Table 8-2: P7370 Keypad Functions
KEY
FUNCTION
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within the menu. This is similar to an “Enter” key.
Primary Function: Allows the user to scroll through available systems, groups, or channels, depending on
personality programming.
Secondary Function: Changes the selection for an item within a list.
Primary Function: Refer to the separate key definitions within this table.
0-9,
and
Secondary Function: These keys function much as a typical DTMF telephone pad 0-9, *, and # keys; and
are used to place telephone interconnect and individual (unit-to-unit) calls.
Selects a specific system. If the rotary knob is used to select the system and more than 16 systems are
programmed in the radio, the
key is used to select additional banks (groupings) of systems.
Selects a specific group.
Turns the Scan operation ON and OFF.
Enables or disables Private Mode for the system/group/channel displayed.
Adds groups or channels from the currently selected system to the Scan list.
Status. Access to the status list (0-9). The Status key permits the transmission of a pre-programmed status
message to an EDACS site.
Message. Access to the message list (0-9). The Message key permits the transmission of a preprogrammed message to an EDACS site.
Deletes selected groups or channels of the currently selected system from the Scan list.
Initiates telephone interconnect calls.
Initiates individual unit-to-unit calls.
37
MM-013994-001, Rev. Ap1
8.2
DISPLAY
The radio display is made up of 3 lines (see Figure 8-3). Lines 1 and 2 contain eight alphanumeric
character blocks and are used primarily to display system and group names. Line 1 also displays radio
status messages. The 3rd line is used primarily to display radio status icons. All three lines are used to
display menu options when in the menu mode. If programmed, the display backlighting will illuminate
upon power up or when radio controls are operated.
Figure 8-3: P7300 Radio Display
38
MM-013994-001, Rev. Ap1
8.3
RADIO STATUS ICONS
Status Icons indicate the various operating characteristics of the radio. The icons show operating modes
and conditions and appear on the third line of the display (see Table 8-3).
Table 8-3: EDACS Icon Descriptions
EDACS STATUS ICONS
st
Steady – during all radio transmissions. Appears in the 1 position of the display.
nd
Steady – “Busy” transmitting or receiving. Appears in the 2 position of the display.
Flashing – call queued.
™
th
Steady – trunked system in Failsoft mode. Appears in the 4 position of the display.
th
Steady – transmit at low power. Appears in the 5 position of the display.
If icon is not visible – transmit at high power.
th
Steady – transmit in encrypt mode. Appears in the 6 position of the display.
Flashing – receiving an encrypted call.
Steady – Indicates the current channel is set up as a ProVoice channel. Appears in the 7
position of the display.
th
th
Animated (rotates clockwise) – scan mode enabled. Appears in the 9 position of the display.
If icon is not visible – scan is disabled.
th
Steady – priority 1 group or channel. Appears in the 10 position of the display.
th
Steady – priority 2 group or channel. Appears in the 10 position of the display.
th
Steady – group or channel in scan list. Appears in the 10 position of the display.
th
Steady – special call mode (individual or telephone). Appears in the 11 position of the
display.
th
Steady – battery charge indicators. Appear in the 12 position of the display.
Flashing – Low battery indicator.
Figure 8-4: Full Cycle Battery Charge Indicator
The battery charge indicators illustrate approximate level only, based on battery voltage. Refer to Figure
8-4.
39
MM-013994-001, Rev. Ap1
8.4
TRI-COLOR LED
Figure 8-5: Tri-Color LED
The Tri-Color LED changes color to indicate radio status and is visible from both the front and top of the
radio (see Figure 8-5). The colors of the LED and the status they represent are defined below.
8.5
Green:
Receiving
Red:
Unencrypted transmission
Orange:
Encrypted transmission
STATUS MESSAGES
During radio operation, various radio Status Messages can be displayed. The messages are described
below.
MESSAGE
QUEUED
40
NAME
Call Queued
DESCRIPTION
Indicates the system has placed the call in a request queue.
SYS BUSY System Busy
Indicates the system is busy, no channels are currently available, the queue
is full, or an individual call is being attempted to a radio that is currently
transmitting.
DENIED
Call Denied
Indicates the radio or talkgroup is not authorized to operate on the selected
system and/or talkgroup.
CC SCAN
Control
Indicates the control channel is lost and the radio has entered the Control
Channel Scan Channel Scan mode to search for the control channel (usually out of range
indication).
WA SCAN
Wide Area
Scan
Indicates the radio has entered the Wide Area Scan mode to search for a
new system (if enabled through programming).
SYSC ON
System Scan
Features On
Indicates the System Scan features are enabled.
MM-013994-001, Rev. Ap1
MESSAGE
8.6
NAME
DESCRIPTION
SYSC OFF System Scan
Features Off
Indicates the System Scan features are disabled.
LOW BATT Low Battery
Battery voltage has dropped to the point to where the radio is no longer able
to transmit. The radio will still receive calls until the battery is discharged
beyond the point of operation at which time the radio automatically shuts
down.
RXEMER
Receive
Emergency
Indicates an emergency call is being received. This message will be
flashing on line two.
TXEMER
Transmit
Emergency
Indicates an emergency call has been transmitted on this radio. This
message will be flashing on line two.
VOL=31
Volume Level Indicates the current volume level. The volume level display ranges from
OFF (muted) to 40 (loudest).
WHC
Who Has
Called
Indicates an individual call has been received, but not responded to. The
indicator turns OFF if the individual call mode is entered, the system is
changed, or the radio is turned off and then on again.
UNKNOWN
Unknown ID
Indicates an individual call is being received from an unknown ID.
ERROR MESSAGES
If either of the Error Messages shown below is displayed, the radio is programmed incorrectly or needs
servicing.
or DIG V x
DSP ERR
ERR=XXXX
ERR
(PowerUp
only)
Where xxxx is the error code and DSP ERR or DIG V ERR is the message.
41
MM-013994-001, Rev. Ap1
8.7
ALERT TONES
The P7300 radio provides audible Alert Tones or “beeps” to indicate the various operating conditions (see
Table 8-4).
Table 8-4: Alert Tones
NAME
TONE
DESCRIPTION
Call Originate
one short mid-pitched
OK to talk after pressing the push-to-talk button
Call Queued
one high-pitched
Call queued for processing
Autokey
one mid-pitched
Queued call received channel assignment
System Busy
three low-pitched
System busy or unable to complete call
Call Denied
one low-pitched
Radio is not authorized on the system or group
Carrier Control Timer
five high-pitched/one long
low-pitched
PTT depressed for maximum length of time
Low Battery
one low-pitched/one short
mid-pitched
Low battery
TX Low Battery Alert
one low-pitched
8.8
After PTT - battery too low to transmit
TURNING ON THE RADIO
1. Power ON the radio by rotating the POWER ON-OFF/VOLUME knob clockwise. A short alert
signal (if enabled through programming) indicates the radio is ready to use.
2. The display shows the last selected system and group or a default system and group (depending on
programming).
3. Adjust the POWER ON-OFF/VOLUME knob to the desired volume level.
4. Select the desired system and group. The display indicates the current system and group names.
5. The radio is now ready to transmit and receive calls.
In the trunked environment, CC SCAN will be displayed if communication with the
system's control channel cannot be established. This may occur if, for example, the
radio is out of range of the trunking site. It may be necessary to move to another
location or select another trunking system to re-establish the control channel link for
trunked mode operations. CC SCAN is displayed on the group line until a control
channel is accessed.
42
MM-013994-001, Rev. Ap1
8.9
SYSTEM SELECTION
METHOD 1:
From the control knob: If system selection is programmed to the
System/Group/Channel control knob, select a system by turning the knob to
the desired system number position (1-16). The display registers the new
system name on line one. The
button can be programmed to provide
access to a “2nd bank” of 16 system number positions (17-32).
METHOD 2:
From the keypad: If system selection is programmed as the primary function
and
, select a system by pressing
or
to scroll through the
of
system list. The display registers the new system name on line one.
METHOD 3:
to enter the system
(P7370 model radios only) Direct Access: Press
select mode. Press the numeric key, which is mapped to the desired system.
Press
. The radio will move to the selected system.
If system selection is programmed to the System/Group/Channel control knob, direct
access to systems will not be available. Pressing
or
will scroll through
different sets of 16 systems each (banks) if more than 16 systems are programmed into
the radio.
The systems within each bank are then selectable via the
System/Group/Channel control knob as described previously in METHOD 1.
Example:
System: 1 = North
2 = South
3 = East
4 = West
8.10
Group: 1 = Group 1
2 = Group 2
3 = Group 3
4 = Group 4
1. Press
. (South is the currently selected system.)
2. Press
. (Press 4 to select “West” system.)
3. Press
. (West is the newly selected system.)
GROUP/CHANNEL SELECTION
Several methods can be used to select a new group or channel.
METHOD 1:
From the Control knob: If group selection is programmed to the System/Group/Channel
control knob, select a group by turning the System/Group/Channel control knob to the
desired group number position. The display registers the new group name on line two.
If the knob is moved to a position greater than the number of programmed groups, the
highest programmed group will remain selected. The button can be programmed to
provide access to a “2nd bank” of 16 group number positions (17-32).
METHOD 2:
and
From keypad: If group selection is programmed as the primary function of
select a group by pressing
or
to scroll through the group list. The display
registers the new group name on line two.
METHOD 3:
to enter the group select mode.
(P7370 model radios only) Direct Access: Press
. The radio will move to
Press the numeric key mapped to the desired group. Press
the selected group.
43
MM-013994-001, Rev. Ap1
8.11
MODIFY SCAN LIST
8.11.1
P7370 Model
1. Press
to toggle scan OFF and verify
is not displayed.
2. Select group or channel.
3. Press
once to remove group or channel from list.
4. Press
once to add as a normal group or channel.
5. Press
twice to add as a Priority 2 group.
6. Press
three times to add as a Priority 1 group.
7. Press
to re-start scanning.
8.11.2
P7350 Model
1. Press
to toggle scan OFF and verify
is not displayed.
2. Select group or channel.
8.12
3. Press
once to remove group or channel from the list.
4. Press
once to add as a normal group or channel.
5. Press
twice to add as a Priority 2 group.
6. Press
three times to add as a Priority 1 group.
7. Press
to re-start scanning.
MENU
The Menu function accesses features that are not available directly from the keypad. The order and actual
menu items available is configurable through programming. Upon radio power up, the menu item that is
at the top of the menu list will always be displayed first. Subsequent access to the menu function will
return the last menu item that was shown in the display and cursor position.
1. To enter the menu mode, then press
2. Upon entering the menu selection mode, Menu options will appear in the display (see Figure 8-6).
Figure 8-6: Menu Display
3. The radio will continue to receive and transmit normally while in the menu function.
or
4. To scroll through the menu options use the
found, align the cursor with the option then press
shown in the display can now be changed by using
values.
44
keys. When the required menu item has been
to select it. The menu item's parameter setting
or
to scroll through the list of parameter
MM-013994-001, Rev. Ap1
5. Once the desired setting is reached press
level.
to store the value and return the menu option selection
or
For menu items that display radio information, pressing
informational displays. Possible menu items are listed in Table 8-5.
8.12.1
will scroll through a list of
Menu Item Selection Process
An example of the backlight menu item selection process and menu item parameter change is shown in
Figure 8-7.
1. Press
. The menu mode is entered.
2. Press
or
until the display shows:
Figure 8-7: Backlight Menu Item Selection Parameter
. The backlight menu item is activated. Line one shows the active menu item and its
3. Press
current parameter setting. Line two shows the currently selected system or group name (see Figure
8-8).
Figure 8-8: Backlight Menu Display
4. The menu item's parameter setting shown in the display can now be changed by using
5. Once the desired setting is reached press
level.
or
to store the value and return the menu option selection
or
will scroll through a list of
For menu items that display radio information pressing
informational displays. An example of information displays is shown in Table 8-5.
The TX POWER menu item, when selected, toggles LOW/HIGH power. It does not use
or
to scroll nor is an additional press of the
button required.
45
MM-013994-001, Rev. Ap1
Table 8-5: Menu Item Information
FEATURE
Keypad Lock
Backlight Adjust
Contrast Adjust
Transmit Power Select
Radio Revision Information
Toggle Scan On/Off
Toggle Private Mode
Display Current Encryption
Key
Display Current Home
Group/Channel
Select Desired System
Add Group/Channel to Scan
List
Delete Group/Channel
Add/Delete Scan List
Select Telephone Numbers
From Phone List
Data Operation
Select Individual Call from
IC List
Select Group
Feature Encryption Display
System Scan Enable
46
DISPLAY
PARAMETER
SETTING
Menu Item:
KEY LOCK
Once Selected:
LOCKED
Menu Item:
BCK LIGHT
Once Selected:
BCKL=
Menu Item:
CONTRAST
Once Selected:
CNTRST=
Menu Item:
TX POWER
Once Selected:
POWER=
Menu Item:
REVISION
SCAN
PRIVATE
DISP KEY
ON/OFF
ON/OFF
N/A
HOME
COMMENT
Locked
Unlocked
Locks the keypad. To unlock; press and release
then within
1 second press the option button NOTE: This sequence is also a
short cut to locking the keypad.
OFF, 1 thru 6
Selects the light level for backlighting.
1, 2, 3, 4
Selects the display contrast level.
HIGH or LOW
Selects radio output power mode.
N/A
N/A
Selects the information display to view. Informational display only
(see Table 8-6). No user selectable settings.
Toggles Scan operation ON/OFF.
Toggles Private Mode ON/OFF.
Displays current encryption key. Informational display only. No
selectable settings.
Selects Home Group/Channel
SYS SEL
SCAN ADD
N/A
N/A
Selects a new system.
Adds to Scan List.
SCAN DEL
SCAN A/D
PHN CALL
N/A
N/A
N/A
Deletes Group or Channel from Scan List.
Add or Delete from Scan List.
Trunked Only.
NO DATA
IND CALL
ON/OFF
N/A
Trunked Only. Toggles Data Operation ON/OFF.
Trunked Only.
GRP SEL
Menu Item:
FEATURES
N/A
N/A
Trunked Only.
Indicates current features programmed into the radio as well as
certain information required to add features to the radio.
Informational display only. No user selectable settings.
Toggles System Scan feature ON/OFF.
Menu Item:
ON/OFF
SYS SCAN
Once Selected:
SYSC ON or SYSC
OFF
MM-013994-001, Rev. Ap1
Table 8-6: Information Display
RADIO ID
XXXXXXXX
LID in EDACS/EA In CONV it has no
meaning.
RAM SIZ
RAM Size
FLSH SIZ
Flash Size
RF BAND
Frequency Band
PERS VER
Software Version
DSP DATE
Date DSP code was built.
DSP TIME
DSP FEAT
DSP VER
Time DSP code was built.
The DSP Features supported by the
DSP code, in Hexadecimal.
Bit mapped (see IPC spec for details):
• 0x0001 – Conventional
• 0x0002 – EDACS
• 0x0010 – AMPF
• 0x0020 – undefined
DSP Software Version
FLSH VER
FLASH Software
ex: P73U0102
P=portable, 54=5400 radio,
U=unencrypted, 01=major revision (>50
means unreleased code), 02=minor
revision
HARRIS
(C) 2009
8.13
8.14
Copyright
PERSNLTY
Personality Name
BLD DATE
Date host (ARM) code was built.
BLD TIME
Time host (ARM) code was built.
BACKLIGHT ADJUST
1. Press
to access the menu.
2. Press
or
3. Press
to select Backlight menu.
4. Press
or
5. Press
to select new backlight setting.
to scroll through menu until “BCKLGHT” appears.
to scroll through available settings OFF, 1 through 6.
CONTRAST ADJUST
1. Press
to access the menu.
2. Press
or
3. Press
to select Contrast menu.
4. Press
or
5. Press
to select new contrast setting.
to scroll through menu until “CONTRAST” appears.
to adjust contrast setting from 1 - 4.
47
MM-013994-001, Rev. Ap1
8.15
DECLARING AN EMERGENCY
1. Press and hold the red Emergency/Home button (the length of time is programmable; check with the
system administrator).
2. *TXEMER* will flash in the display, plus
transmit icon
and
will be displayed. After 2-3 seconds the
will turn off.
3. *TXEMER* and
will remain until the emergency is cleared. See Section 8.21 for additional
emergency operation.
4. Press the PTT and
will reappear.
5. Release PTT when the transmission is complete.
8.16
LOCKING/UNLOCKING KEYPAD
1. Press
button.
2. Within 1 second, press the
8.17
button on the side of the radio.
HIGH/LOW POWER ADJUSTMENT
Transmit power adjustment is possible if enabled through programming. Within conventional systems,
transmit power is adjustable on a per channel basis. Within EDACS trunking systems, transmit power is
adjustable on a per system basis.
There are two ways to toggle between high and low power, described in Sections 8.17.1 and 8.17.2.
8.17.1
1. Press
Using the Menu Button
2. Using the
display.
3. Press
or
keys, scroll until the cursor (>) appears to the left of “TX POWER” in the
again to toggle between High and Low power.
4. “POWER = HIGH” or “POWER = LOW” will appear momentarily on the top line of the display.
8.17.2
Using the Pre-Programmed Option Button
Press the Option button. “POWER = HIGH” or “POWER = LOW” will appear momentarily on the top
line of the display.
8.18
DIGITAL VOICE OPERATION
Digital voice programmed systems have three (3) different voice modes: clear (analog), digital, and
private (encrypted). The voice modes are programmed on a per-group basis within each trunked system
and on a per-channel basis within each conventional system.
48
MM-013994-001, Rev. Ap1
8.18.1
Clear Mode
The Clear Mode is a voice mode in which the radio transmits and receives only clear (analog) voice
signals. These analog signals are non-digitized and non-encrypted. Clear mode transmissions can be
monitored easily by unauthorized persons.
Groups or channels programmed for clear operation cannot transmit or receive digital or
private messages.
8.18.2
Digital Mode
The Digital Mode allows the radio to transmit and receive digitized voice signals. Digital signals provide
improved weak signal performance and cannot be easily monitored with a standard receiver. Groups or
channels programmed for digital operation transmit only digital signals. Message trunked group calls and
individual phone calls (I-Calls) are answered back in the mode in which they were received assuming the
call or hang time is still active. Individual phone, all call, and emergency calls are transmitted clear if the
digital mode is disabled or inoperative.
1. If receiving an analog message trunked call, the radio responds in the analog mode during the
hang time on the working channel.
2. If receiving an analog I-Call, the radio responds in the analog mode during the hang time.
3. When using the *WHC* feature to respond to an I-Call (after the hang time has expired), the call
is transmitted in the mode defined by the system mode as programmed for the current system if
the ID being called is not in the I-Call list. If the ID is in the I-Call list, then the call is transmitted
as defined by the I-Call mode programmed in the list for that ID.
The overdial DTMF tones are not available while in the Digital Mode.
8.18.3
Private Mode
The Private Mode allows the radio to transmit encrypted messages and receive clear or private
transmissions. The radio transmits private if the group/channel is programmed for private operation and
forced operation is pre-programmed. If auto-select operation is pre-programmed and the radio is in the
Private Mode, the radio transmits in the mode of the received call if the hang time is active. If no hang
time is active, the radio transmits private.
Cryptographic keys are transferred to the radio using a cryptographic Keyloader. Up to seven (7)
different cryptographic keys, numbered 1-7, can be transferred from a Keyloader and stored in the radio.
An individual key is automatically selected on a per-group/channel basis according to the radio
programming. Groups and channels within the digital system can be programmed for keys 1-7 (private).
Up to 8 banks of 7 keys can be stored for private systems. The bank is specified per system.
When operating on a group or channel programmed for Private Mode, all transmissions are private
transmissions and the radio receives clear and private signals. The status icon is displayed when the
Private Mode is enabled. If the selected group or channel is programmed for auto-select capability, the
mode may be toggled between private and clear with the
key, then following the selection mode
rules. Radios programmed for forced private operation do not allow a change of the transmit mode.
49
MM-013994-001, Rev. Ap1
8.18.3.1 Displaying the Currently Used Cryptographic Key Number
To display the Currently Used Cryptographic Key Number for either the system encryption key (for
special call such as individual, phone, all, agency or fleet) or the group/channel key (for group or
conventional calls), perform the following procedure:
1. Press the
2. Use the
button.
or
button to select "DISP KEY."
or
button to toggle between displaying the system key (Figure 8-9) or the
3. Use the
group/channel key (Figure 8-10).
Figure 8-9: System Encryption Key Display
Figure 8-10: Group/Channel Encryption Key Display
8.18.3.2 Key Zero
All cryptographic keys can be zeroed (erased from radio memory) by pressing the button and while still
pressing this button, press and hold the OPTION button. Press both buttons for 2 seconds. A series of
beeps will begin at the start of the 2 second period and then switch to a solid tone after the keys have been
zeroed. The display will indicate KEY ZERO.
If the cryptographic key(s) are zeroed, one or more keys must be transferred from the Keyloader into the
radio before private communications may continue.
8.18.4
Private Operation
8.18.4.1 Receiving an Encrypted Call
When receiving, the radio automatically switches between clear or private operation. If the transmission
being received is an encrypted transmission, it will be decrypted, the icon will be displayed, the receiver
will unsquelch, and the message will be heard in the speaker. For this to occur, the selected group or
channel must be programmed for private operation and the correct cryptographic key must be loaded into
the radio.
8.18.4.2 Transmitting an Encrypted Call
1. Select the desired group or channel.
key; then follow the selection mode rules. On a
2. Place the radio in Private Mode by pressing
System radio, the
key can be used to toggle the Private Mode ON/OFF. When Private Mode is
enabled, the icon is displayed.
50
MM-013994-001, Rev. Ap1
3. If the last state of the radio was Private Mode, the Private Mode will be enabled on power up. Also,
the Private Mode will be enabled if forced operation has been programmed in the radio.
If a group or channel is not programmed for Private Mode operation, PVT DIS will be displayed if
an attempt is made to enable private transmit mode. It is not possible to operate on this group/channel
in Private Mode.
If the radio does not have the correct encryption key loaded, NO KEY# will be displayed and the call
will not be transmitted.
4. Continue with standard transmission procedures. A Private Mode access tone will be heard when the
PTT button is pressed.
8.18.4.3 Scanned Group Calls
Receiving a Scanned Group Call is the same as receiving a selected group call. During the scan hang
time, if the radio was programmed for auto-select, it will transmit back in the same mode it received the
call. For example, if a clear group is entered in the scan list, it will only receive clear calls. If the same
group was available in private and entered in the scan list, it can receive clear and private calls, provided
auto-select was programmed in the radio. The user can select transmitting on the scanned or selected
group. If a group is entered in the scan list more than once and under different modes, (clear, digital, or
private), then only the first occurrence of the group will be used.
Table 8-7: Transmit/Receive Mode Compatibility for Digital Voice Operation
GROUP/CHANNEL
PROGRAMMING
(TRANSMIT)
CLEAR
RECEIVE
DIGITAL
RECEIVE
PRIVATE
RECEIVE
CLEAR
DIGITAL
Yes
Yes
No
Yes
No
No
PRIVATE
Yes
No
Yes*
*assumes the proper cryptographic key is loaded
Conventional digital or encrypted channels require Channel Guard on the channel to
operate correctly.
The voice coding technology embodied in this product is protected by intellectual
property rights including patent rights, copyrights, and trade secrets of Digital Voice
Systems, Inc. The user of this technology is explicitly prohibited from attempting to decompile, reverse engineer, or to disassemble the Object Code, or in any other way
convert the Object Code into a human-readable form.
8.19
SCANNING TRUNKED GROUPS
Groups that have been previously added to the scan list on a per system basis may be scanned. Each
system's group scan list is retained in memory when the radio is powered OFF or when the battery pack is
removed.
51
MM-013994-001, Rev. Ap1
8.19.1
Turning Scan On and Off
1. Toggle Scan operation ON by pressing
clockwise to indicate radio is scanning.
(P7350 model) or
2. Toggle Scan operation OFF by again pressing
disappear.
(P7370 model).
(P7350 model) or
icon rotates
(P7370 model).
will
•
If the radio scans to a group other than the selected group then receives a call on the selected
group, the radio will switch to the selected group. However, if the “scanned-to” group is
programmed at a higher priority the radio will remain on the “scanned-to” group.
•
The radio will continue scanning if a new group is selected when scan is ON.
3. Pressing the PTT button when scan is ON will cause the radio to transmit on the displayed group or to
the currently selected group (depending on programming).
8.19.2
Adding Groups to a Scan List
P7350 Model Radio
1. Scan must be OFF to add/delete groups to/from the scan list. If the Scan icon
key to turn Scan OFF.
is ON, press the
2. Select the desired group using the System/Group/Channel control knob and/or the
the selected group is currently on the list, pressing
will display on line three.
or
3. If the scan list status icon is blank ( ), the group can be added to the scan list by pressing the
will be displayed on line three.
4. Press the
key a second time to set the group to Priority 2. A
keys. If
key.
is displayed on line three.
a third time to set the group to Priority 1. A is displayed on line three. The priority level
5. Press
section sequence only advances the group to the next high priority level and stops at priority level 1.
To select a lower priority level, the group must be deleted from the scan list and then added back to
the scan list. Each new group added to the scan list starts at the lowest priority. If the Priority 1 and
Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously
assigned group will change to non-priority scanning. One of the following messages may be
momentarily displayed.
SCAN DIS
The radio is not programmed to scan.
FIXED P1
A Priority 1 group has been pre-programmed into the radio. A new Priority 1 group
cannot be selected.
FIXD LST
A fixed scan list has been pre-programmed into the radio. It is not possible to change
the list without reprogramming the radio.
To quickly view multiple group scan status, press
then slowly but consistently rotate
the group knob. Each group status will appear on the display.
52
MM-013994-001, Rev. Ap1
P7370 Model Radio
1. With scan operation turned OFF, select the desired group to add to the selected trunked system group
scan list.
. The current priority status of the group will be displayed in column 10 of line three for a
2. Press
time-out period. If the group is not part of the scan list, the status will be blank.
3. While the status is displayed, press
4. Press
to add the group to the scan list.
a second time to set the group to Priority 2. A
is displayed on line three.
is displayed on line three.
a third time to set the group to Priority 1. A is displayed on line three. The priority level
5. Press
selection sequence only advances the group to next higher priority level and stops at priority level 1.
To select a lower priority level, the group must be deleted from the scan list and then added back to
the scan list. Each new group added to the scan list starts at the lowest priority. If the Priority 1 and
Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously
assigned group will change to non-priority scanning. One of the following messages may be
momentarily displayed.
SCAN DIS
The radio is not programmed to scan.
FIXED P1
A Priority 1 group has been pre-programmed into the radio. A new Priority 1 group
cannot be selected.
FIXD LST
A fixed scan list has been pre-programmed into the radio. It is not possible to change
the list without reprogramming the radio.
To quickly view multiple group scan status, press either
or the
key. Then slowly
but consistently rotate the group knob. Each group status will appear on the display.
8.19.3
Deleting Groups from a Scan List
P7350 Model Radio
1. With scan operation turned OFF, select the desired group to delete from the selected trunked system
group scan list.
2. Press
. The current status of the group is displayed for a time-out period.
. until the group from the scan list is "blank." The
3. While the current status is displayed, press
sequence is "blank," , , , "blank." Any group that is not in a trunked system group scan list will
show a "blank" for the time-out period when it is the selected channel.
P7370 Model Radio
1. With scan operation turned OFF, select the desired group to delete from the selected trunked system's
group scan list.
2. Press
. The current status of the group is displayed for a time-out period.
to delete the group from the scan list. , ,or turns OFF.
3. While the status is displayed, press
Any group that is not in a trunked system group scan list will show a "blank" for the time out period
when it is the selected channel.
53
MM-013994-001, Rev. Ap1
8.19.4
Nuisance Delete
A group can also be deleted from the scan list, if it is not the currently selected group, by pressing the
key (P7350 model) or the
key (P7370 model) during scan operation while the radio is displaying the
unwanted group. The group will be deleted from the system's group scan list in the same manner as if
done using the steps above. Deletions done in this manner will not remain deleted if the radio is powered
OFF and then powered ON.
8.20
SCANNING TRUNKED SYSTEMS
The radio can be programmed using Radio Personality Manager (RPM) with the following System Scan
features. Then these features are automatically enabled when the radio is powered ON. A key or menu
option is also defined to allow the System Scan features to be toggled during radio operation. The System
Scan state will be maintained through system changes but will default to ON when the radio is powered
ON.
Enable/Disable via Menu Selection
Press
and then use the
or
buttons to scroll through the selections until SYS SCAN is
displayed. Then press
to toggle the System Scan state. The SYSC ON or SYSC OFF display
message is displayed for two seconds to show the new state.
Enable/Disable via Pre-Programmed Keypad Key
Press the key pre-programmed to toggle System Scan and the SYSC ON or SYSC OFF display message
is displayed for two seconds to show the new state.
8.20.1
Wide Area System Scanning
The P7300 series radio can be pre-programmed through RPM for Wide Area System Scan operation for
roaming across mobile systems. EDACS radio systems manage the radios assigned to the system via a
control channel (CC). Upon the loss of the currently selected system's control channel, radios can be
programmed to automatically scan the control channels of other systems. If a new control channel is
found, the radio will switch to the new system and sound an alert tone.
8.20.2
Priority System Scan
The radio can also be pre-programmed for Priority System Scan. The priority system is the desired or
preferred system. While receiving the control channel of the selected system, the radio will periodically
leave the selected system and search for the control channel of the priority system. This is done at a preprogrammed rate defined by the value in the Priority Scan Time control, unless the ProScan™ algorithm is
enabled, as explained in the following sections. This priority scan timer is reset each time the PTT button
is pressed or when the call is received. If the priority system control channel is found, or meets the
predefined criteria (ProScan), the radio will automatically switch to the priority system.
8.20.2.1 Enabling the Wide Area System Scan Function
If the radio cannot find the control channel of the selected system and begins to wide area system scan,
the radio will only scan for the priority system control channel if the priority system is in the wide area
scan list.
54
MM-013994-001, Rev. Ap1
8.20.2.2 When ProScan is Enabled
The radio monitors the priority system and will switch to the priority system if the pre-preogrammed
criteria ProScan options are met. If ProScan is enabled, the rate at which the radio will scan for the
priority system is defined by the System Sample Time control, set in RPM, (refer to RPM On-Line Help).
See Section 8.20.3 for more information on ProScan.
8.20.3
ProScan
The radio may be programmed for ProScan system scan operation for multi-site applications. ProScan is
a multi-site system scanning algorithm. ProScan provides the radio with the ability to select a new
system for the radio to communicate on, when the selected system drops below a predefined level. This
algorithm enables each radio to analyze the signal quality of its current control channel and compare it
with the signal quality of the control channel for each site in its adjacent scan list. The signal quality
metric used for the ProScan algorithm is based on a combination of both Received Signal Strength
Indicator (RSSI) and Control Channel Verification (CCV) measurements. When the selected system
degrades to a pre-programmed level, the radio will begin to look for a better control channel. Once a
control channel that exceeds the pre-programmed parameters is found, the radio will change to the new
system and emit a tone (if enabled through programming). If the control channel is completely lost, the
radio will enter Wide Area System scanning and search the programmed adjacent systems until a suitable
control channel is found.
8.21
EMERGENCY OPERATION
The radio's ability to declare an emergency, clear an emergency, remain locked on an emergency system
and group, and the emergency audio and display freeze can each be enabled or disabled through
programming. When an emergency is declared scanning will stop and restarts only after the emergency
has been cleared.
8.21.1
Receiving an Emergency Call
When receiving an Emergency Call on the selected group and system, an alert beep is heard and is
displayed. The message *RXEMER* flashes in the display on line two until the emergency condition is
cleared.
8.21.2
Declaring an Emergency Call
Perform the following steps to send an emergency call to a selected system and group (or on an optionally
pre-programmed group).
1. Press and hold the red EMERGENCY button that is on top of the radio in front of the antenna for
approximately one second (this time is programmable and therefore could be longer or shorter; check
with the system administrator). The radio will transmit an emergency call request with the radio ID
until an emergency channel assignment is received.
2. When the working channel assignment is received, the radio sounds a single beep indicating the radio
has auto keyed (see Table 8-4) and is ready for voice transmission. *TXEMER* flashes on line two in
the display until the emergency is cleared.
3. Press PTT and speak into the microphone in a normal voice.
and
momentarily turn ON.
4. Release PTT when the transmission is complete.
To clear the emergency, first press and hold the button. While continuing to hold the button, press
the EMERGENCY button. (This will work if the radio is programmed to clear emergencies.)
55
MM-013994-001, Rev. Ap1
8.22
INDIVIDUAL CALLS
8.22.1
Receiving and Responding to an Individual Call
When the radio receives an individual call (a call directed only to the user's radio), it un-mutes on the
assigned working channel and displays . The first line on the display shows the logical ID number of the
unit sending the message, or the associated name if the ID number is found in the individual call list. The
radio can be programmed to ring when an individual call is received. If enabled, the ring begins five
seconds after the caller un-keys and will continue until the PTT button, the button or the individual call
mode is entered.
The volume of the ring is adjustable through the volume control levels.
If a response is made by pressing the PTT to the call prior to the programmed call-back time-out, the call
will automatically be directed to the originating unit. If a response is not made before the call-back timeout, the radio will return to normal receive display, and *WHC* will appear on the first line of the LCD.
key. The radio's display will show the callers ID on
To respond after the call-back time-out, press the
the first line and WHCI=1 on the second line. Pressing the PTT button at this point will initiate an
individual call back to the original caller.
The radio stores the IDs of the last 10 callers in the Calls Received List as shown. Individual calls are
stored in the top half of the list (1-10) and Group calls are stored in the bottom half of the list (1-10). The
most recent call is stored in position 1, the second most recent call is stored in position 2, etc.
Figure 8-11: Calls Received Lists
To access the Calls Received List, press the
key twice. Use the
or
buttons to scroll through
the list. Pressing the
key will display the time elapsed since the call was received. After pressing
the display will appear similar to Figure 8-12.
56
MM-013994-001, Rev. Ap1
Figure 8-12: WHC Individual Call Display
Pressing the PTT will initiate an individual call to the displayed logical ID. Powering the radio OFF and
ON will clear this list.
8.22.2
Sending an Individual Call
8.22.2.1 Pre-Stored Individual Calls
The following procedures describe how to initiate and complete a Pre-Stored Individual Call.
P7370 Model Radio
1. To select a pre-stored individual phone number, enter the individual call mode using the
displayed. Then scroll through the list of stored numbers using the
or
keys.
key.
is
2. Press the PTT button; when the radio is clear to transmit, turns ON, turns OFF, and the channel
access tone sounds. Line one shows the called individual's name if found in the list of stored
individuals or LID followed by the logical ID number of the unit being called. The message *INDV*
displays on line two.
P7350 Model Radio
1. To select a pre-stored individual number, enter the menu mode by pressing the
through the mode list using the
or
buttons.
key. Scroll
is displayed. Scroll through the list of stored phone numbers using the
2. Press
buttons until the desired number is displayed. Press
or
3. Press the PTT button; when the radio is clear to transmit turns ON, turns OFF, and the channel
access tone sounds. Line one shows the called individual's name or LID. The message *INDV*
displays on line two.
8.22.2.2 Direct Dial Individual Calls (P7370 Model Only)
1. The following procedure describes how to initiate and complete a Direct Dial Individual Call.
2. The individual call ID is not stored in the pre-stored list of call IDs but the individual unit ID is
known, it can be entered directly from the keypad.
3. Press and hold the PTT button to transmit. will turn ON,
will turn OFF, and the channel access
tone will sound. Line one shows the called individual's ID followed by the logical ID number of the
unit being called. The message *INDV* displays on line two. Proceed talking into the microphone.
8.22.3
Call Storage Lists
There are two lists available for call storage in the P7300 series radios, the calls received list (1 - 10) and
the personality list (1 - 99 as defined by the user). When the individual call mode is entered by pressing
, the calls received list is available. The user can toggle to the personality list by selecting any index
57
MM-013994-001, Rev. Ap1
other than 0 or toggle between the two lists by pressing the
list wraps on itself and not into the other list.
key. If wrap is enabled, the calls received
Figure 8-13: Calls Received and Personality Lists
The saved call list shows all ten storage locations. If no calls have been received, the saved call list will be
empty and the pre-stored list will be available upon entering the individual call mode.
When in the saved call list, pressing the
key toggles the time stamp ON and OFF. The time stamp
indicates how long ago the call was received. When in the pre-stored list pressing the
key toggles the
Logical IDentification (LID) ON and OFF.
8.23
TELEPHONE INTERCONNECT CALLS
8.23.1
Receiving a Telephone Interconnect Call
When the radio receives a telephone interconnect call (a call directed only to the user's radio), it un-mutes
on the assigned working channel and displays . The first line displays *PHONE*. The second line
displays *INDV*. Proceed with the call. Press the PTT to talk, release the PTT to listen.
8.23.2
Sending a Telephone Interconnect Call
8.23.2.1 Pre-Stored Number
Use the following procedures to initiate and complete a Telephone Interconnect call.
key. Use the
or
key. Use the
P7350 Model: To select a previously stored phone number, press the
buttons to select the menu option PHN CALL. Press the
key again then use the
buttons to scroll through the list of pre-stored numbers.
or
or
1. P7370 Model: To select a previously stored phone number, press the
buttons to scroll through the list of stored numbers.
2. Press and release the PTT button. When the radio is clear to transmit, turns ON, turns OFF, and
the channel access tone sounds. Line one shows the accompanying name selected from the list of
stored numbers. The message *PHONE* appears on line two of the display. The radio then
automatically transmits the programmed number stored in the special call queue.
3. A telephone ring will be heard from the speaker. When someone answers the phone, press the PTT
button and speak into the microphone. Release the PTT button to listen to the callee. Unsuccessful
58
MM-013994-001, Rev. Ap1
interconnect signaling returns the radio to the normal receive mode and the number remains displayed
until the special call is cleared or the time-out expires or another group or system is selected.
Terminate a call by pressing the button.
In half-duplex mode, only one person may talk at a time. The radio PTT button needs
to be pressed in order to communicate to the individual called and released for the
individual called to be heard.
8.23.2.2 Direct Dialing of Phone Calls (P7370 Model Only)
1. If the phone number is not stored in the pre-stored list of phone numbers, but the phone number is
known, it can be entered directly from the keypad. Start by pressing the
key, then enter the
required number from the keypad. Press and release the PTT button.
The last number directly entered can be recalled by first pressing
PTT button.
then pressing the
2. A telephone ring can be heard from the speaker. When someone answers the phone, press and hold
the PTT button and speak into the microphone. Release the PTT button to listen to the individual
called. Unsuccessful interconnect signaling returns the radio to the normal receive mode and the
number remains displayed until the special call is cleared or the time-out expires or another group or
system is selected.
3. To terminate the call, momentarily press the
8.23.3
button.
Dual-Tone Multi-Frequency: Overdial/Conventional Mode
Once the radio has established a connection to the public telephone system, it may be necessary to “overdial” more digits to access banking services, answering machines, credit card calls, or other types of
systems that require Dual-Tone Multi-Frequency (DTMF) access digits.
Overdial operation can also be used to initiate a telephone interconnect call via DTMF signaling if a dial
tone has already been accessed on the system. This method makes a telephone interconnect call while
operating in the conventional mode but will also function in trunked mode if a dial tone is directly
accessible.
Telephone numbers and other number sequences for overdialing can be stored in the phone list when
key, then following the selection
programming the radio. These numbers are accessed by pressing the
mode rules. Perform the following procedures to access and dial these stored numbers.
P7350 Model Radio
1. Follow the procedure in Section 8.23.2 to establish a connection to the telephone system or consult
the system administrator for the procedure to access a dial tone on the trunked or conventional
system.
2. Enter selection mode first to enable entry of Overdial numbers by pressing the
button.
or
3. Follow the selection mode rules to call up a stored number from the phone list: Use the
buttons to scroll through the list of stored numbers. is displayed. Press the PTT to send the overdial
sequence once. If the number needs to be transmitted again it must be selected or entered again (this
prevents unwanted numbers from being sent the next time the PTT button is pressed during the call).
59
MM-013994-001, Rev. Ap1
Overdial select/entry mode remains active until the call is dropped, cleared, or
overdial select/entry mode can be re-entered if the call is still active by pressing
is pressed. The
P7370 Model Radio
1. Follow the procedure in Section 8.23.2 to establish a connection to the telephone system or consult
the system administrator for the procedure to access a dial tone on the trunked or conventional
system.
2. Overdial numbers are transmitted using one of the following methods:
METHOD 1:
1. Enter the overdial selection mode by pressing the
button.
2. Use the
or
buttons to scroll through the list of stored numbers. is
displayed. Press the PTT to send the overdial sequence once. If the number
needs to be transmitted again it must be selected or entered again (this
prevents unwanted numbers from being sent the next time the PTT button
is pressed during the call).
Overdial select/entry mode remains active until the call is dropped, cleared, or
is pressed. The overdial select/entry mode can be re-entered if the call is
still active by pressing
METHOD 2:
(P7370 model radios only)
button.
1. Enter the overdial selection mode by pressing the
2. Press and hold the PTT button while entering the overdial number
sequence from the keypad. This method sends DTMF tones during
individual, telephone interconnect, trunked group, or conventional channel
calls. Press the PTT to send the overdial sequence once. If the number
needs to be transmitted again it must be selected or entered again (this
prevents unwanted numbers from being sent the next time the PTT button
is pressed during the call). Note: Anytime the PTT button is pressed and
held, the keypad is enabled for DTMF entry.
Overdial select/entry mode remains active until the call is dropped, cleared, or
is pressed. The overdial select/entry mode can be re-entered if the call is
still active by pressing
This overdial select/entry mode remains active until dropped, cleared, or
select/entry mode can be re-entered if the call is still active by pressing the
8.24
is pressed. The overdial
button.
PROGRAMMABLE ENTRIES
8.24.1
Pre-Storing Individual and Telephone Interconnect Calls from the
Keypad
Individual Call ID numbers, telephone numbers, and other number sequences for overdialing are stored in
the special calls lists when programming the radio. The first ten entry locations of these lists can be
changed by the radio operator. The keypad is used when adding, changing, and storing numbers in these
entry locations.
Use the following procedure to store a number in one of the first ten entries of a special call list:
1. Press the
or
button to enter the individual call list or the phone call list.
2. Scroll through the list using the
or
ENTRY is displayed if the location is empty.
60
is displayed.
keys until one of the first ten entries is reached. NO
MM-013994-001, Rev. Ap1
3. Enter the desired number. If necessary, a pause can be entered by pressing and holding 0-9,
, or
until an underscore appears in the display (telephone interconnect only). The individual call list
entries will accept up to 5 digits. The phone call list entries accept a combination of up to 31 digits
and pauses.
4. Press and hold the
key until the display changes indicating that the number has been stored.
Repeat steps 1-4 to store additional numbers, to change numbers already stored, or to change the storage
location of a number.
8.25
STATUS/MESSAGE OPERATION
The Status and Message operations allow for the transmission of a pre-programmed status or a preprogrammed message to an EDACS site. Each Status and Message is assigned an ID then crossreferenced with the representative status condition (“Off Duty,” for example) or a message (“Call home”).
In addition, Status conditions can also be associated with a programmable Menu entry (required for
second method of transmitting a Status condition (see Section 8.25.1).
8.25.1
Status Operation
P7370 Model Radio
One of two methods can be used to transmit a status condition.
METHOD 1:
1. Press the
key, then use the
or
buttons to scroll to the pre-programmed
status condition. STATUS and 0 through 9 pre-programmed status selections are
available from the menu.
2. If STATUS is selected, you need to enter the number of the status condition you
intend to transmit. If no status has been programmed for the selected number key,
the radio will display NO ENTRY. A valid selection will display the status for a preprogrammed time.
key has been pressed (the
key will override the
After the time-out expires or the
time-out period), the status is selected and will be transmitted to the site or stored in the
radio memory where it can be polled by the site at a future time.
METHOD 2:
1. Press the
key.
2. Press the corresponding pre-programmed 0 through 9 status condition key. If no
status has been programmed for the selected number key, the radio will display
NO ENTRY. A valid selection will permit the status condition to appear in the top
line of the display and the status ID to appear in the second line of the display for a
pre-programmed time.
After the time-out expires or the
key has been pressed (the
key will override the
time-out period), the status is selected and will be transmitted to the site or stored in the
radio memory where it can be polled by the site at a future time.
View the currently selected status after it has been transmitted by pressing the
key and then the
key and then the button prior to the time-out period. If the status was not sent successfully to the site,
the text associated with the status condition will flash in the display.
The status selection can be changed by pressing a different status key 0 through 9, or the status operation
can be cancelled by pressing Option Button 2 . Both operations must be carried out prior to the timeout period.
61
MM-013994-001, Rev. Ap1
8.25.2
Message Operation
The following method can be used to transmit a Message using the Message Operation.
1. Press the
key.
2. Press the corresponding pre-programmed 0 through 9 pre-programmed “message” key. If no message
has been programmed for the selected number key, the radio will display NO ENTRY. A valid
selection will permit the message to appear in the top line of the display and the message ID to appear
in the second line of the display for a pre-programmed time.
The message selection can be changed by pressing a different message key 0 through 9, or the message
operation can be cancelled by pressing Option Button 2 . Both operations must be carried out prior to
the pre-programmed time-out period.
8.26
DYNAMIC REGROUP OPERATION
Dynamic Regroup Operation permits multiple talk groups (up to eight) to be added to a radio via the
system manager. The radio must be pre-programmed to respond to regrouping. Dynamic regrouping will
not be activated in a radio until the system manager sends an activation message. Each radio that receives
and acknowledges the regrouping instructions is successfully regrouped.
Pressing and holding the button for 2.5 seconds toggles the user into and out of the dynamic regroup
groupset. A double beep will sound for entry or exit. The display will indicate REGRP_0x where "x" is a
digit of 1 to 8 indicating the group (when dynamic regroup has been enabled by the user). If the radio is in
dynamic regroup and the user selects a group that has not been regrouped, the display will show NO
ENTRY. The radio will be prevented from transmitting and receiving calls in this condition except for
scanned groups.
key has been pressed (the
key will override the time-out
After the time-out expires or the
period), the status is selected and will be transmitted to the site or stored in the radio memory where it can
be polled by the site at a future time.
8.26.1
Emergency Operation
If the pre-programmed groupset on the currently selected system contains an EMER/HOME group and
the radio is in dynamic regroup, the radio will declare the emergency on the currently selected dynamic
group.
8.27
MACRO KEY OPERATION
Macro key operation permits the user to accomplish a series of keystrokes with a single "macro"
keystroke. Each Macro Key is capable of executing up to twenty (20) keystrokes, to any push button input
(i.e., keypad keys, OPTION buttons, etc.). Each macro key can be pre-programmed to activate when
pressed or when released.
A macro key may also be pre-programmed to change the key stroke sequence the next time the macro key
is activated.
For detailed operation and assignment of macro keys, contact your communications supervisor or
administrator.
8.28
PORTABLE DATA
The P7300 series portable radios, when operating in the EDACS Trunked configuration, permit both
voice and data calls to be transmitted and received. The radio can handle only one type of call at a time;
62
MM-013994-001, Rev. Ap1
however, either data or voice is selected transparently by the operator through normal usage of the radio.
Data communications is not supported in conventional mode.
The radios can be connected to a Mobile Data Terminal (MDT) or to a host computer. Any RS-232
compatible device that supports the Radio Data Interface (RDI) protocol (Version 1.91 or greater) may be
connected to the radio. Support for MDTs or host computers is a programmable option per radio.
Additionally, radios may also be programmed for data only operation (no voice calls transmitted or
received).
8.28.1
Displays
The following will be displayed during the various states of data mode of operation:
TX DATA
Appears on top line of display when the radio is transmitting a data call.
RX DATA
Appears on top line of display when the radio is receiving a data call.
DATA OFF
Appears on top line of display when the radio is in the data disabled state.
DATA ON
Appears for two seconds on top line of display when the radio is toggled to the data
enabled state.
8.28.2
DATA OFF Operation
The radio can be placed in the data disabled state by any of the following methods. When the data state is
disabled, DATA OFF appears on the top line of the display.
•
Declaring an emergency (not to be used unless an actual emergency condition exists). Alert tone will
sound.
•
Pressing Option Button 1
•
Pressing the pre-programmed “no data” (ND) key. Refer to previous bullet.
8.28.3
(if pre-programmed as “no data” key). Alert tone will sound.
DATA ON Operation
The data state is enabled by one of the following (depending on how it was disabled). DATA ON will
appear on the top line in the display for two seconds then the display will return to normal.
•
Pressing the pre-programmed “no data” (ND) key toggles data state ON or OFF.
•
Clearing an emergency. This is valid only if the emergency caused “DATA OFF” operation.
8.28.4
Exiting Data Calls
Under normal conditions, the radio enters the scan lockout mode and returns to the control channel after
completion of a data call (transmit or receive). If, during a data call, one of the following operations
occurs, the data call is immediately terminated and the radio performs the desired function:
•
If the PTT is activated.
•
If an Emergency is declared by pressing the pre-programmed emergency button.
•
If a group or system is changed.
8.28.5
Scan Lockout Mode
Following the transmission or reception of a data call, if scan is enabled, scanning will stop temporarily.
There are two independent pre-programmed times associated with this mode; one after a received data
63
MM-013994-001, Rev. Ap1
call and one after a transmitted data call. During this time the scan indicator will flash to indicate that scan
is enabled but temporarily suspended. This condition typically returns to normal scan operation when the
pre-programmed time expires; however, the following operations and conditions will terminate the scan
lockout mode before the timeout has expired.
•
Press the
•
Press the PTT.
•
Change a group or system.
•
Enter Telephone Interconnect mode.
•
Enter Individual call mode.
•
Receive a new emergency assignment.
•
Declare or clear an emergency.
•
Receive an individual or phone call.
•
Receive an Agency, Fleet, or System All Call.
•
Press
8.28.6
button.
(P7350 model) or
(P7370 model) to toggle Scan ON or OFF.
Data Lockout Mode
During the voice call scan hang time (pre-programmed) the radio does not receive data calls.
64
MM-013994-001, Rev. Ap1
This page intentionally left blank
65
MM-013994-001, Rev. Ap1
OPENSKY OPERATION
66
MM-013994-001, Rev. Ap1
OPENSKY OPERATION
Once an OpenSky system has been selected from the available systems on your P7300 series portable
radio, the characteristics described in the following sections will govern operation.
9.1
CONTROLS
The P7300 portable radio features two rotary control knobs, an emergency button, and a dual-position
A/B switch located on the top of the radio. Refer to Figure 7-2. The Push-To-Talk (PTT) button and two
option buttons are located to the left side of the radio keypad, see Figure 7-3. The front mounted keypad
of the P7370 “System” model has 15 buttons and the P7350 “Scan” model has six buttons. Refer to
Figure 7-4 and Figure 7-5, respectively.
9.1.1
Buttons and Knobs
The function of the button and knob controls will vary depending on the mode of operation. The primary
functions of the button and knob controls when in the OpenSky mode of operation are listed in the
following paragraphs.
POWER
ON-OFF
VOLUME KNOB
Applies power to the radio and adjusts audio volume.
Rotating the control clockwise applies power to the radio. A single alert tone (if
enabled through programming) indicates the radio is operational.
Rotating the control clockwise increases the volume level. While adjusting the
volume the display will momentarily indicate the volume level (i.e. VOL=31). The
volume range is from a minimum programmed level of zero (displayed as MUTE in
the display) up to 40, which is the loudest level.
VOICE GROUP
SELECTION
KNOB
Used to select voice groups when operating within an OpenSky system. This is a
16-position rotary knob.
A mechanical stop, which can limit the number of positions accessed, is shipped
with the radio but must be installed. To install the mechanical stop, remove the
voice group selection knob, loosen the set screw on the voice group selection knob
metal base (using a 1.27 mm hex wrench), and remove the voice group selection
knob metal base. Replace the 16 channel ring with the channel stop ring located at
the desired channel. Re-install the voice group selection knob metal base, tighten
the set screw, and re-install the voice group selection knob.
EMERGENCY
BUTTON
Press to declare an emergency. To clear an emergency, press and hold Option 2
button . While holding , press the emergency button. Release both buttons
when the “emergency cleared” tone sounds.
PTT BUTTON
The Push-To-Talk button must be pressed before voice transmission begins.
SIDE OPTION
BUTTON 1
SIDE OPTION
BUTTON 2
Scrolls UP or DOWN thru available items within a sub-menu, such as available talk
groups, pre-programmed speed dial numbers, canned alert messages, etc.
67
MM-013994-001, Rev. Ap1
9.1.2
Keypad
The keys on the keypad have special functions and are labeled using a symbol or abbreviated word
describing its primary function. Numeric entry is a secondary function of the keys. Each key is described
in Table 9-1.
Table 9-1: Keypad Functions
KEY
FUNCTION
Primary function: Acts much as an “enter” button to activate a selection.
Secondary function: While in the “dwell display,” press repeatedly to scroll
through and view status display (on 2nd line) for current profile, caller, received
talk group, and channel.
Scrolls thru available menu items (see Table 9-4).
(P7350 only)
(P7350 only)
(P7350 only)
Undefined in OTP mode.
Toggles SCAN operation ON and OFF.
Undefined in OTP mode.
The alpha-numeric keys are used to place telephone interconnect and
individual (unit-to-unit) calls. The keys operate like a normal telephone
keypad.
Also used to enter passwords for logging into the OpenSky network, if not preconfigured for automatic registration at power-up.
(P7370 Only)
(P7370 Only)
(P7370 Only)
68
Initiates OpenSky functions (log in, log out, selective call, telephone
interconnect call, etc.). See page 76 for additional information. It is also used
as an escape or to clear an entry (something like backspace, but it clears
everything and not only the last digit/character).
Used in conjunction with alpha-numeric keys for passwords and OpenSky
functions. See page 76 for additional information.
MM-013994-001, Rev. Ap1
9.2
RADIO STATUS ICONS
Status Icons indicate the various operating characteristics of the radio. The icons show operating modes
and conditions and appear on the third line of the display (see Table 9-2).
Table 9-2: Status Icons Descriptions
OPENSKY ICONS
st
nd
Steady – Received Signal Strength Indicator (RSSI). Appears in the 1 and 2 position of the display in OpenSky
mode.
rd
Steady – Radio is data registered. Appears in the 3 position of the display in OpenSky mode.
Steady – Stealth mode is enabled, all tones and the display backlight are disabled, voice is still heard. Appears in the
th
4 position of the display in OpenSky mode.
th
Steady - Radio is transmitting or receiving an encrypted voice call. Appears in the 6 position of the display.
Animated – The radio is scanning for a VTAC. Once the radio has attached to a VTAC, the icon will turn off. The icon
th
appears in the 7 position of the display in OpenSky mode.
th
VTAC Connection Indicator – Indicates the client is connected to a VTAC. Appears in the 8 position of the display in
OpenSky mode.
Steady – Indicates Scan mode is Normal or Fixed. Is not displayed when Scan mode is None. Appears in the 9
position of the display in OpenSky mode.
th
th
Steady – Indicates Selective Call mode. Appears in the 11 position of the display in OpenSky mode.
th
Steady – Battery charge indicator. Appears in the 12 position of the display.
Flashing – Low battery indicator.
Figure 9-1: Full Cycle Battery Charge Indicator
The battery charge indicators illustrate approximate level only, based on battery voltage. Refer to Figure
9-1.
69
MM-013994-001, Rev. Ap1
9.3
TRI-COLOR LED
Figure 9-2: Tri-Color LED
The Tri-Color LED changes color to indicate radio status and is visible from both the front and top of the
radio (see Figure 9-2). The radio states reflected by the LED are:
Green:
Receiving
Red:
Transmitting
If the LED is flashing rapidly, the radio is receiving an emergency call. If the
LED is flashing every ½ second, the selected talk group is in the emergency state
(although not transmitting). If the selected talk group is in the emergency state,
an asterisk will be displayed next to the talk group name.
9.4
LOG IN TO THE NETWORK
Login occurs either automatically (auto registration) if the radio has a valid registration or, if enabled,
requires the user to enter a User ID and password.
The user will be prompted to “Pls Login” with the *1 login command, a User ID, and password.
keys (Login command).
1. Press *1,
2. Enter the full 10-digit User ID.
3. Press the
key.
4. Enter the password.
•
If the radio is configured for alpha-numeric passwords and the password has consecutive
key, between the consecutive
duplicate numbers (“MES33” for example), enter #, the
duplicate numbers so the radio will not interpret the entry as a letter (“D” in this example).
•
If the radio is configured for numeric-only passwords, do not press the
duplicated numbers.
5. Press the
key between
key twice.
The User ID may be remembered from the previous log-in. (Refer to Section 9.5 for further details
regarding log-off commands.) The password will be established before the radio is put into operation.
Contact the local OpenSky network administrator for more information.
70
MM-013994-001, Rev. Ap1
If necessary, contact radio system administration personnel for log-in assistance and/or
radio-specific log-in instructions.
9.5
LOG OFF THE NETWORK
The *0## command de-registers the radio. Typically, this is automatically performed when powering
down the radio. Using this method, the User ID is remembered by the radio so only the password is
needed at next log-in. Log-off manually by pressing
If a user is logged in, it is necessary to log-off.
9.6
PERSONALITY
As illustrated in Figure 9-3, a personality defines the profiles and talk groups available to the user. It is
the structuring of a collection of profiles and privileges established by the OpenSky network administrator
to provide the user with a comprehensive set of profiles to communicate effectively with the necessary
talk groups or individuals.
Personalities are stored on the network and downloaded over-the-air to the radio. This process is called
“provisioning.” Provisioning occurs at radio power-up (if the personality is not already stored in the
radio’s memory) and at user log-in. When changes are made to the personality, the radio is automatically
re-provisioned. Each personality can contain up to sixteen (16) profiles and each profile can contain up to
sixteen talk groups.
9.6.1
Profiles
As stated above, each profile can contain up to sixteen (16) talk groups. A profile also defines the radio’s
emergency behavior. All transmissions are made on the selected talk group (displayed on the top line of
the dwell display). The user can change the selected talk group to any of the other talk groups within the
profile.
71
MM-013994-001, Rev. Ap1
Profile 1
Profile 2
Profile 3
TG a
TG d
TG a
TG b
TG e
TG d
TG c
TG f
TG g
TG x
TG h
TG y
TG i
TG z
TG = Talk Group
Figure 9-3: Personality Structure Example
9.6.2
Talk Groups
A talk group represents a set of users that regularly need to communicate with one another. There can be
any number of authorized users assigned to a talk group. Talk groups are established and organized by the
OpenSky network administrator. An OpenSky talk group is similar to a channel within a conventional FM
radio system.
9.7
OPENSKY DISPLAY OVERVIEW
The 12-character x 3-line display shows the radio status. The first two lines of the display are text lines
that change in response to user interaction with the menu buttons. Status icons appear in the bottom line
(line 3) of the display (see Table 9-2).
9.7.1
Display’s Top Line
The display’s top line of text changes as the
and
buttons are pressed to scroll through the
available menu options (see Table 9-4). When the dwell display is present, the selected talk group will be
displayed. Other information, such as alert messages will scroll across the top line of the display.
9.7.2
Display’s Second Line
The second line will display information such as active menu, login prompt, emergency status, and dwell
display messages as described in the following section.
9.7.3
Dwell Display
When not engaged in menu selection, the first two lines of the display default to the user-defined display,
known as the “dwell display.” The top line indicates the currently selected talk group. The second line
will display the currently selected profile, caller ID/alias1, received talk group, and current channel name.
Press the
button repeatedly to scroll through and view one of these second line options.
Alias is a logical ID name such as “J_Smith.” The name corresponds to a user ID such as 003-542-0001.
72
MM-013994-001, Rev. Ap1
9.8
ALERT TONES
The P7300 radio also provides audible Alert Tones or “beeps” to indicate the various operating conditions
(see Table 9-3).
Table 9-3: Alert Tones
NAME
TONE
DESCRIPTION
Call Queued
one low tone/two high tones
Call is queued for processing.
Call Denied
three short beeps
Radio is out of coverage area or requested talk group is active.
Grant (or Go-Ahead)
single short beep
Sounded when resources become available for a call request
placed in the queue (if enabled) upon channel access.
If the radio roams to another site while transmitting, then it
will auto rekey and begin transmitting on that tower. It gives a
second grant tone to let the user know they have roamed.
Call Removed
single long low-pitched tone
Notifies the user access to the channel has been lost (out of
coverage area or pre-empted by higher-priority call).
Low Battery
one low-pitched/one short midpitched
Low battery
Selective Alert Received
four short tones
Only played once to indicate a selective alert has been receive.
Emergency Alert Tone
three long beeps
Sounds when an emergency alert is declared.
Emergency Cleared Tone
one long low-pitched tone
Sounds when an emergency is cleared.
Selective Call Ring Tone
a ringing tone similar to a
telephone
Ringing is repeated every four (4) seconds until the call is
accepted or rejected by the radio being called or until the
network drops the call if unanswered after one (1) minute.
Roam Tone
two short tones, one highpitched and one low-pitched
Sounds when the radio transitions from one radio base station
site to another.
Out of Range Tone
three brief tones
If enabled via programming, sounds at a programmable
interval while the radio is in a state of persistent deactivation.
73
MM-013994-001, Rev. Ap1
9.9
BASIC MENU STRUCTURE
Table 9-4 illustrates the basic P7300 OpenSky menu structure. Menu items will vary depending upon
system programming, radio hardware, and optional configurations. All menus except the dwell display
menu can be turned off by network administration personnel.
Table 9-4: Basic P7300 OpenSky Menu Structure
Menu Name
Radio Displays
Usage Notes
(first and second lines)
To/From Dwell Display
Engineering Display
(Menu may not be available
per programming.)
Silent Emergency
Operating Mode
(e.g., OTP, OCF)
GPS Fix
[e.g., GPS, GPS (Site), GPS
(Aged)]
User ID
registration, RF sync and
transceiver status codes
bit-error rates
and RSSI data
OFF/ON
“SilentEmerg”
available modes
“Mode Menu”
current latitude and longitude
(degrees:minutes:seconds)
“GPS”
Displays radio system connection data. For engineering use.
or
Use
enable.
to toggle between OFF/ON. Press
to
Use
or
to choose an available mode. Press
confirm (Y/N) with
or
and
again.
and
GPS latitude and longitude position of currently tuned-to
base station [“GPS (Site)”] or V-TAC (“GPS”) scrolls across
top line of the display. “GPS (Aged)” indicates VTAC
coordinates haven’t been updated for more that 2 minutes.
User ID # of user currently logged
User’s identification/name scrolls across top line of the
in
display (if programmed).
“User ID”
IP Address
Radio’s IP address
“IP Address”
Radio’s Internet Protocol (IP) address scrolls across top line
of the display.
Station Identification
station’s call sign
“Station ID”
Station’s identification/name scrolls across top line of the
display (if programmed).
“OFF”
Use
or
to turn on. On P7350, press any button to turn
it off. On P7370, use Stealth Menu or press 2# to disable 2#
to disable Stealth mode.
Stealth Mode
(display backlight is disabled)
“StealthMenu”
Treble Level
“LOW”, “MEDIUM”, “MEDHIGH”,
“HIGH”
“Treble Menu”
Use
or
to choose speaker treble level. Press
return to dwell display.
to
Display Brightness
“<< >>”
“Bright Menu”
or
to brighten or dim backlighting. Press
Use
return to dwell display.
to
Side Tone Level
“OFF”, “LOW”, “MED”, HIGH”
“Side Menu”
See Next Page
74
or
to choose side tone level. Press
Use
to dwell display.
to return
MM-013994-001, Rev. Ap1
Menu Name
Radio Displays
Usage Notes
(first and second lines)
See Previous Page
Selected Channel
selected channel
(Menu may not be available
per radio programming)
“ChannelMenu”
Displays the current channel. Press
display.
to return to dwell
(e.g. Normal, None, Fixed)
current scan mode
“ScnModeMenu”
Talk group
Lock Out
talk group “<”
“LockOutMenu”
Priority 2
Talk group
current priority talk group
“Priority2”
or
to choose Priority 2 talk group. Press
Use
return to dwell display.
to
Priority 1
Talk group
current priority talk group
“Priority1”
Use
or
to choose Priority 1 talk group. Press
return to dwell display.
to
Alerts Received
time/sender’s name/
alias/message text
“AlertsRcvd”
or oldest message
“No alerts” or alert message text scrolls in display. Use
to view all messages.
or
Scan Mode
current speed dial #
Alert Destination
“AlertDest”
Speed Dial
current speed dial #
“SpeedDial”
Profile Selection
currently active profile
“ProfileMenu”
Talk group Selection
selected talk group
“TalkGrpMenu”
Emergency Dismiss
alert received
“EmgDismiss”
Dwell Display
selected talk group
(bottom line option)
Use
and
Use
or
to scroll between scan modes (Normal, None,
and Fixed). Press
to return to dwell display.
Use
Press
or
to choose a talk group for locking/unlocking.
to toggle “<” on (locked out) and off.
Use
or
to choose a speed-dial number. Press
to
go to the “Alert Msg” menu. Use
or
to scroll through
to send message and return
“canned messages.” Press
to dwell display.
or
to choose a speed-dial number and press PTT
Use
to place call.
or
to choose an available profile. Press
Use
return to dwell display.
Use
to
or
to choose a talk group in current profile. Press
to return to dwell display.
or
to choose emergency talk group. Press
Use
toggle “<” on (dismiss) and off.
Press
to
to change bottom line option.
to scroll through menus.
75
MM-013994-001, Rev. Ap1
9.10
KEYPAD FUNCTION COMMANDS (P7370 ONLY)
To perform a command from the keypad, use the keypad commands in Table 9-5.
Table 9-5: Keypad Function Commands
*0
*1
*4
*6
*7
*8
*9
*32
*33
*61
*62
*60
76
Log-off command: *0## (logs the user off the system). See Section 9.5 for additional information.
Key presses:
Log-in command: *1 #  ## (required for encryption). See Section 9.2 for
additional information. Key presses:


Enter Scene of Incident Mode (SOI) on specified channel and band: *4## where LC
is the channel number that is being used as a SOI repeater and band is the number assigned to each
frequency band. For example, if LC 25 800 MHz (band 0) is being used for SOI, then enter
*4,25,#,0,#.
Exit SOI Mode with *4# Key presses:
Go to Default Profile. Selects default profile if the radio is not voice registered.
Initiate Selective Alert command: *7#[Choose Message]#. See Section 9.25 for
additional information. Exit SOI Mode with *4#. Command:
Radio-to-Radio Call command: *8#(PTT to dial).

then press PTT to dial
Command:
Public Switched Telephone Network (PSTN) Call command: *9 #(PTT to
dial) See Section 9.26 for additional information. Command:

then press PTT to dial
Begin Manual Encryption command: *32#
1-16 digit encryption key for 128 bit encryption; 17-32 digit encryption key for 256 bit encryption.
End Manual Encryption command: *33#
Initiate XCOV Mode: Extended coverage for individual users.
Initiate XCOV-TG Mode: Extended coverage for talk groups.
Exit XCOV or XCOV-TG Mode: Returns to the normal mode.
MM-013994-001, Rev. Ap1
9.11
QUICK KEYS (P7370 ONLY)
Quick Keys are a two-button sequence that provides the user with quick access to certain menu items.
Quick Keys function as a toggle for these menu items.
Table 9-6: Quick Key Sequence
QUICK
KEYS
1#
2#
3#
4#
6#
9.12
9.13
FUNCTION
Transition to ECP mode
If ECP code is not loaded in the radio, “No App” appears in the display
Toggles Stealth Mode On/Off
Toggles Scan Mode On/Off (Normal/Fixed, see details below)
• If the Scan Mode is Normal when the Scan Mode is toggled Off, the Scan Mode will be
Normal when toggled On again.
• If the Scan Mode is Fixed when the Scan Mode is toggled Off, the Scan Mode will be
Fixed when scan mode is toggled On again.
• If the Scan Mode is Off when the radio boots up, the Scan Mode will be Normal when
Scan Mode is toggled On.
Lights/Tones On/Off
Pressing 4# turns the TX/RX LEDs, Backlight, and Side Tones On/Off.
If any of the TX/RX LEDs, Backlight, and/or Side Tones are On, and this quick key sequence
is used, then all of the TX/RX LEDs, Backlight, and Side Tones are turned Off.
If the radio is in Stealth mode, this quick key is disabled since the user is not able to turn on
the light/tones in stealth mode.
XCOV & XCOV-TG Attach/Detach
This quick key sequence is used to manually connect to a V-TAC. When attaching to a
V-TAC, the radio’s programming determines whether to attach to the V-TAC in XCOV or
XCOV-TG mode.
1. If the user attaches to a V-TAC manually, using the *61# or *62# command sequence, the
radio is understood to be attached and this quick key sequence will detach the radio from
the VTAC.
2. If the user detaches manually from a V-TAC using the *60# command sequence, the radio
is understood to be detached and this quick key sequence will attach the radio to a VTAC.
3. At bootup, the radio is understood to be detached from a VTAC. If a radio automatically
attaches to a VTAC, the radio is still understood to be detached from a VTAC and will
attempt to attach to a VTAC.
4. If a radio manually attaches to a VTAC and then is automatically detached from a VTAC, the
radio is still understood to be attached to a VTAC and will attempt to detach from a VTAC.
LOCK/UNLOCK THE KEYPAD
1. Press and hold the
button.
2. While holding the
button, press the
button on the side of the radio.
DUAL-TONE MULTI-FREQUENCY (P7370 ONLY)
Dual-Tone Multi-Frequency (DTMF) is the system used by touch-tone telephones. DTMF assigns a
specific tone frequency to each key so a microprocessor can easily identify its activation. This allows for
specific tasks such as entering a user ID and password, or selective calling.
77
MM-013994-001, Rev. Ap1
When a key on the DTMF keypad is pressed, the DTMF tone is played through the radio’s speaker.
9.14
CHANGING THE ACTIVE PROFILE
The radio can store up to sixteen (16) standard profiles, one of which is the currently active profile. To
change the currently active profile:
1. Press the
2. Use
or
or
buttons until “ProfileMenu” is displayed.
to scroll through the list of available profiles.
is pressed, or when the
3. Profile becomes active when selected for longer than 2 seconds, when the
menu is changed using the
or
button. Press
to activate the selected profile.
9.15
CHANGING THE SELECTED TALK GROUP
Each profile stored in the radio can have up to sixteen (16) talk groups. One talk group within the
currently active profile is set as the “selected talk group.” To change the selected talk group, turn the
Group Selection knob on top of the radio.
9.16
ADJUSTING DISPLAY AND BUTTON BACKLIGHT BRIGHTNESS
1. Press the
2. Use
9.17
or
or
buttons until “Bright Menu” is displayed.
to brighten or dim the display and button backlighting.
STEALTH MODE
For some users, it is important to be able to turn off the radio’s display lights and side tones, but not the
radio traffic. For example, in covert operations, lights and sounds could inadvertently expose an
otherwise unobservable radio user. For this purpose, the radio has a Stealth feature that disables the radio
display light, indicator light, and audible side tones.
When Stealth Mode is on, the radio continues to scan the programmed list of talk groups and the user can
key-up on the selected talk group.
9.17.1
Enabling Stealth Mode
P7370 only: Quick Key combination 2# toggles Stealth Mode on and off.
or
buttons to scroll through menus until “StealthMenu” appears in the
Both models: Press the
display. To immediately activate Stealth Mode press the
or
button once. This activates Stealth
Mode, exits the Stealth Menu, and returns to the Dwell Display.
The display lights, indicator lights, and side tones are disabled. The Stealth Mode icon is displayed.
9.17.2
Disabling Stealth Mode
P7370 only: To re-enable all lighting, side tones and exit Stealth Mode, press Quick Key combination 2#
again. The radio returns to the Dwell Display.
P7350 only: To re-enable all lighting, side tones and exit Stealth Mode, press any key other than PTT or
the Emergency button. The radio returns to the Dwell Display.
The display lights, indicator lights, and side tones are re-enabled. The Stealth Mode icon disappears.
78
MM-013994-001, Rev. Ap1
9.17.3
Stealth Mode using A/B Switch
It is also possible to enable and disable Stealth Mode using the A/B Switch, if so programmed.
Depending on programming the switch in one position will enable Stealth Mode and in the other position,
disables it.
With Stealth Mode on the P7350 model radio, pressing any radio button (other than
the mic’s PTT button or the Emergency button) on the front panel will immediately
turn Stealth Mode off. For example, pressing the
button on the front panel will
turn stealth mode off.
9.18
ADJUSTING SIDE TONE AUDIO LEVEL
The radio sounds confirming tones called “side tones” when its buttons are pressed. Most users find this
audible confirmation helpful when navigating the menus. Side tone audio level can be adjusted or turned
completely off using the “Side Menu.”
For covert operations, it may be necessary to turn off side tones. For safety’s sake, turning off the radio
during covert operations is not recommended.
If the radio is operating properly but side tones are not heard when the menu buttons are pressed, the side
tones are probably turned off. To turn them back on, access the “Side Tone” menu and select a setting
other than “off.”
Use the following procedure set side tone level:
or
1. Press the
buttons to cycle through the menu until “Side Menu” is displayed.
or
to change to the desired level (Off, Low, Medium, and High). To turn side tones
2. Press
completely off, use the “Off” setting.
9.19
CHANGE OPERATING MODE
1. Press the
2. Press
9.20
or
or
buttons to cycle through the menu until “Mode Menu” is displayed.
to select the desired operating mode.
3. Press
and use
or
to select Y or N.
4. Press
again to make selection and return to the dwell display.
RECEIVING AND TRANSMITTING VOICE CALLS
As soon as the radio completes the initialization sequence and registers on the OpenSky network, the user
will begin to hear calls from the talk groups in the active profile, if available.
9.20.1
Receiving a Voice Call
No action is required on the part of the user.
The caller’s alias is only shown when the selected talk group matches the received talk group. Otherwise,
the name of the received talk group is displayed.
9.20.2
Transmitting a Voice Call
1. Select the desired talk group.
79
MM-013994-001, Rev. Ap1
2. Depress and hold the PTT button, wait a couple of seconds. If programmed by the administrator, a
grant tone will be sounded.
3. Begin speaking into the microphone in a normal voice.
4. For maximum clarity, hold the radio approximately 2 inches from your mouth. Take care not to cover
up the microphone while speaking.
5. Release the PTT button to terminate an outgoing voice call.
9.21
ADJUSTING AUDIO TREBLE LEVEL
The tone of received signals can be adjusted using the radio’s “Treble Menu.”
1. Press the
or
buttons to cycle through the menu until “Treble Menu” is displayed.
2. Press or to increase or decrease level. There are four levels available: low, medium, mediumhigh, and high.
3. Press
9.22
or wait a few seconds to return to the dwell display.
TALK GROUP LOCK OUT
There are two ways to focus voice communications by suppressing calls from talk groups in the active
profile.
•
Non. By changing the Scanning Mode to “None” only the selected talk group is scanned.
•
Lock Out. By locking out selected talk groups, background noise or chatter can be eliminated and
scanning resources can be focused on just those groups whose calls you wish to monitor.
Lock out is a listening (receive) function and only blocks received calls on locked out talk
groups. Lock out does not affect transmit capability. “None” and “Lock Out” do not
apply to recent emergency lock outs.
Only talk groups in the active profile can be locked out, since they are the only talk groups whose voice
calls can be heard on the radio. Talk group lock out is a scan-related feature. With lock out, one or more
talk groups in the active profile can be temporarily disabled from being scanned. Calls are not received on
locked-out talk groups. Lock out settings are not retained between profile changes or when the radio is
power cycled.
If the Scan Mode is “Fixed,” P1 and P2 groups CANNOT be locked out. See Section 9.23
for more information.
The default emergency and emergency-capable talk groups can be locked out if they are NOT in an
emergency state. If a talk group is locked out and is subsequently changed to the currently selected talk
group, it will automatically be unlocked by the radio so the user can hear calls on the talk group. The
radio may be configured so all talk groups are automatically locked out by default. In this case, they must
be manually unlocked, if desired.
80
MM-013994-001, Rev. Ap1
9.22.1
Lock Out a Talk Group
1. Use the
display.
or
buttons to scroll through the menu choices until “LockOutMenu” appears in the
2. Use the or keys to scroll through the list of talk groups, if any, until the user group you want to
lock out appears in the display.
3. Press the
key to select the lockable talk group.
4. “<” appears next to the locked out talk group.
9.22.2
Unlock a Talk Group
1. Use the
display.
or
buttons to scroll through the menu choices until “LockOutMenu” appears in the
2. Use the or keys to scroll through the list of talk groups, if any, until the user group you want to
unlock appears in the display.
key to unlock the displayed talk group.
3. Use the
9.23
•
Changing the active profile removes any lockouts you have made.
•
Turning off the radio removes any lockouts you have made.
SCANNING
9.23.1
Selecting Scan Modes
Three scanning modes are available for the radio, but only one can be active at any time. Changing the
scanning mode changes the way the radio scans voice calls for all of the profiles in the radio personality,
no matter which profile is or becomes active.
The choice of scanning mode broadens or narrows the span of communications with all the groups in
profiles you listen to, but does not affect your interaction with those groups you talk with.
The scanning modes available for selection may be limited to a subset of the three scanning modes by the
administrator.
81
MM-013994-001, Rev. Ap1
Table 9-7: Scan Modes
SCAN
MODE
EXPLANATION
None
Eliminates distractions.
Full communications (listen and talk) with the active talk group.
No calls received from other talk groups.
Normal
This is the default setting.
The user can scan all talk groups in the active profile that are not locked out as long as there is demand on the
site.
Priority (P1 and P2) groups are user selectable.
Receive calls from more than one talk group, if available from the current site.
Allows dragging of the selected talk group, P1, P2, and default emergency talk groups to the site on which
the radio is registered. (If other calls are available at the site, they also can be heard but they will not be
actively dragged.)
The default emergency talk group, as well as any emergency-enabled talk groups, is only dragged if it is in
emergency mode.
Fixed
The priority groups are fixed to the selected profile’s pre-defined P1 and P2 groups (configured via the
UAS). In this mode, P1 and P2 groups CANNOT be locked out.
The user can scan all talk groups in the active profile that are not locked out, as long as there is demand on
the site.
Allows dragging of the P1, P2, and selected talk group to the site on which the radio is registered. If other
calls are available at the site, they can also be heard, but they will not be actively dragged.
The default emergency talk group, as well as any emergency-enabled talk groups, is only dragged if in
emergency mode.
The scanning mode choice remains in effect until it is changed. Even if the radio is turned off, the current
scanning mode selection is saved for the next use.
9.23.2
Checking or Changing Active Scan Mode
9.23.2.1 Setting the Scan Mode
1. Press the
2. Use the
Fixed.
3. Press the
or
or
buttons until “ScnModeMenu” appears in the display.
keys to scroll through the list of modes until your choice appears: Normal, None, or
key to activate the scan mode selection and return to the dwell display.
9.23.2.2 Duration of Scanning Mode Selections
Scanning Mode selections survive power down. At startup, the radio defaults to the scanning mode of set
during last use. The last selection made remains in effect until a new selection is made from the Scan
Mode menu.
9.23.3
Scanning Priority
The following lists the scanning priority order (from highest to lowest):
82
•
Selected talk group in emergency state.
•
Default emergency group in emergency state.
MM-013994-001, Rev. Ap1
•
Selected talk group.
•
Emergency capable group in emergency state.
•
Priority 1 talk group.
•
Priority 2 talk group.
•
Other (non-priority).
9.23.3.1 Changing Scan Priority
1. Press the
or
keys until “Priority1” or “Priority2” appears in the display (Priority1 group has
higher priority than the Priorty2 group).
or
2. Press the
key to select and activate the selection. The radio automatically returns to the Dwell
3. Press the
Display.
•
•
•
9.24
button until the desired talk group is displayed.
Changing the priority of a listen group does not change your talk group.
You set priority for two talk groups, but only in the selected profile.
The scanning priority settings are reset to the default values when the radio is turned
off.
MAKING SELECTIVE CALLS
Selective calling is the capability for two voice radio units to obtain and use an independent talk path for a
unit-to-unit call. A properly equipped radio can initiate a selective call to any radio in the system that is
also programmed for selective calls.
In the OpenSky system, a radio can be configured to initiate selective calls through a pre-programmed list
in memory called a speed dial list. Alternatively, a properly equipped radio can initiate a selective call to
any radio in the system by entering the ten-digit User ID (similar to a telephone number) of the target
radio. Some radios are configured to only receive (not initiate) selective calls.
Selective calls are terminated if an emergency is declared. The network limits selective
calls to ten (10) minutes maximum.
If a Selective Call is attempted without registration, “No Priv” is displayed.
9.24.1
Manually Dialing a Selective Call (P7370 Only)
1. Enter *8, the User ID number of the user being called, and the # key (no dashes or spaces). Note that
this feature must be enabled by the administrator.
*8#

83
MM-013994-001, Rev. Ap1
A shortened User ID number can be dialed using the following guidelines:
•
If the radio being called is in the same region and agency – enter only the last four digits.
•
If the radio being called is in the same region, but a different agency – enter the last seven digits.
•
If the radio being called is in another region or if the area is unknown – enter all ten digits.
2. Press PTT (and release) to ring the other user.
The ring tone is sounded.
If the other user accepts the call, the called user’s alias will appear in initiating caller’s display. The
two are now in a unit-to-unit call until one ends the call, the call is terminated due to an initiated
emergency, or the maximum time limit of ten (10) minutes is reached.
If the called radio is busy, “BUSY” will appear in the second line of the display.
9.24.2
Selective Call Using Speed Dial
Speed dial numbers are defined and provisioned by the OpenSky network administrator and
cannot be manually entered into the radio by the user. Contact the administrator if changes
to the speed dial list are required.
1. Scroll through the Menu options using the
or
button until “Speed Dial” appears in the second
line of the display. Using the or keys, scroll through the pre-programmed speed-dial numbers
until the desired number appears in the display and press the PTT button.
OR
2. Press and hold a key associated with a given number for more than three seconds. For example, press
to open the Speed Dial Menu and display the number assigned to that key in the
and hold the
speed dial list. Press the PTT button.
A ring tone is sounded.
If the other user accepts the call, the called user’s alias will appear in initiating caller’s display. The two
are now in a unit-to-unit call until one ends the call, or the call is terminated due to an initiated
emergency.
If the called radio is involved in another selective call, “BUSY” will appear on the second line of the
display. “Unavailable” is displayed when the call has not been answered after a 1 minute timeout or when
the other party is not registered on the network.
9.24.3
Accepting a Selective Call
1. The radio will ring (like a telephone), indicating you are receiving a Selective Call.
2. Press the
, or the
or
buttons to accept the incoming selective call.
3. “CONNECT” will appear in the display, followed by “Lim 10 Min.” “SEL CALL” and the alias of
the caller appear in the display once the call is established.
9.24.4
Rejecting a Selective Call
When a Selective Call is being received (the radio is ringing), you can reject the call by pressing either of
the or buttons or the
key, or by turning the Voice Group Selector Control knob. The call will be
rejected and “Reject” appears on the callers display.
84
MM-013994-001, Rev. Ap1
9.24.5
Terminating a Selective Call
Terminate a Selective Call (call must be active) by pressing the
or
buttons or the
key, or by
turning the Voice Group Selector Control knob. “HANGUP” will appear in the display followed by the
active talk group.
9.25
SELECTIVE ALERTS
Selective alert messaging is an OTP feature that allows one of up to eight (8) pre-programmed (canned)
text messages to be sent from one radio to another. The sender specifies a destination (receiving) radio,
selects one of the pre-programmed text messages, and then transmits it to the destination radio. The
message delivery system adds sender and time-of-day information and forwards the message to the
destination (receiving) radio. The sending radio receives a brief message noting the status of the
transmission.
Received messages are stored in the radio until deleted or until the radio is rebooted. Received messages
do not survive a reboot.
9.25.1
Defining Messages
All selective alert messages are pre-defined. The messages are programmed and provisioned remotely by
your OpenSky system administrator. The radio user cannot create selective alert message content. The
entire selective alert message, including the abbreviation, can be up to 200 characters long.
When sending a selective alert message, the radio may display one of the following status messages
(Table 9-8).
Table 9-8: Status of Selective Alert Messages
STATUS MESSAGE
9.25.2
DEFINITION
Delivering
Select Alert message transmit attempt
Busy
Too busy – Try again
Dest Down
Receiving radio not logged on – Not registered
Not Reg
Transmitting radio not logged on – Not registered
Delivered
Transmission complete
Unreachable
No response
Partial
Transmission interrupted
Sending a Message
The sending process has three steps. First select the destination radio’s User ID, then select the alert
message, and finally send the message.
9.25.2.1 Selecting a Destination Using the Keypad (P7370 Only)
1. Using the keypad, enter *7, the
keys.
At the “AlertDst” prompt, enter the full User ID of the unit to send the message. A shortened User ID
number can be dialed using the following guidelines:
•
If the radio being called is in the same region and agency – enter only the last four digits.
•
If the radio being called is in the same region, but a different agency – enter the last seven digits.
85
MM-013994-001, Rev. Ap1
•
If the radio being called is in another region or if the area is unknown – enter all ten digits.
key to activate the selection.
2. Press the
3. Use the and buttons or the
desired message is displayed.
or
4. Press the
and
buttons to scroll through the available messages until the
key to send the message.
5. Observe Status Messages (Table 9-8) to ensure proper delivery.
9.25.2.2 Selecting a Destination Using the Menu
1. Using the
or
2. Use the or
and press the
button to scroll through the list of User IDs until the desired destination is displayed
key.
or
3. Use the
displayed.
4. Press the
key, scroll through the menu until “AlertDst” (Alert Destination) appears.
buttons to scroll through the available messages until the desired message is
key to send the message.
5. Observe Status Messages (Table 9-8) to ensure proper delivery.
9.25.3
Receiving a Message
When a selective alert message is received by a radio, a four-beep tone is heard. The tone is heard only
once, but the message “NEWALRT” alternates with the talk group on the main display. Up to 8 received
messages can be stored. If a ninth message is received, the first (oldest) message is automatically deleted
to make room for the new message.
Received messages are displayed with the time and source information.
To display a Selective Alert Message:
or
button, scroll through the menu items until “Alerts Rcvd” appears. The oldest
1. Using the
message is displayed and scrolls across the top line of the display.
2. The message includes the time, the User ID, and alias of the sender along with the message.
3. To view the next message, press the
9.25.4
or
button to go forward or backwards.
Deleting a Selective Alert Message
1. Display the message.
2. Press the
key and
or
to select Y or N.
3. At the “Delete? Y” prompt, press the
key. The message will be deleted.
Received messages cannot be saved.
9.26
MAKING INTERCONNECT CALLS (P7370 ONLY)
1. Using the keypad, enter *9, followed by the telephone number being called, and the # key (no dashes
or spaces).
86
MM-013994-001, Rev. Ap1
*9#
Wait a couple of seconds and press and release the PTT button to initiate the call. An initial ring tone
will sound to indicate signal call initiation. Once the gateway picks up the call, the ring tone will
change. Press and hold the PTT and talk normally then release the PTT to listen.
2. To hang up the call, press
9.27
the button or the
key.
EMERGENCY COMMUNICATIONS
The P7300 portable radio is capable of sending an emergency alert and making emergency calls on the
network. The OpenSky system handles emergency calls with the highest priority, allowing you or the
people you serve to get needed help.
Emergency call and alert capability for a profile is configured by the system administrator.
The radio that initiates an emergency alert emits a signal of 3 distinct beeps that only goes
to the dispatch console.
Table 9-9: Emergency Calls vs. Emergency Alerts
EMERGENCY ALERT
EMERGENCY CALL
An Emergency Alert message is
sent to the dispatcher console. The
dispatch
console
plays
an
emergency tone when it receives
the message.
An Emergency Alert message is sent to the dispatcher console. All peers
(radios and consoles) and the dispatch console play the emergency tone
whenever an emergency call is detected. An emergency tone plays for
each new emergency, or when a profile is changed, (assuming there is an
emergency on one of the talk groups for the new profile).
If the orange LED is flashing rapidly, the radio is receiving an
emergency call. If the LED is flashing every ½ second, the selected talk
group is in the emergency state (although not transmitting). If the
selected talk group is in the emergency state, an asterisk displays next to
the talk group name.
No emergency audio (voice)
transmission (hot-mic) capability
available (per programming by
system administrator)
In addition to the Emergency Alert signal, the microphone goes hot for a
predetermined length of time to allow for emergency audio (voice)
transmission. The radio declaring the emergency has channel access
priority. Note that the User can also use the PTT after the pre-determined
hot-mic audio transmission, or during to extend the initial hot-mic audio
transmission.
9.27.1
Declaring an Emergency Call or Alert
1. Press the red emergency button on the radio to enter emergency mode.
The emergency behavior for the selected profile is configured by the network
administrator. This determines whether pressing the Emergency button sends an
Emergency Call or just an Emergency Alert. An Emergency Alert is always part of and
sent with an Emergency Call.
87
MM-013994-001, Rev. Ap1
If the active profile of the unit initiating the emergency is configured to Emergency Alert, the threebeep emergency alert signal is sent only to the dispatcher console.
If the active profile of the unit initiating the emergency is configured to Emergency Call, the threebeep emergency alert signal is sent to the dispatcher console and to all other radios within the selected
talk group. The default emergency talk group becomes the selected talk group. The display will
alternate between the emergency talk group name and “EMERGENCY” to indicate that the
emergency has been initiated.
2. The microphone is hot (open mic) for a programmed amount of time in order to send your voice out
on the emergency talk group.
All of the radios in the emergency talk group hear your call and see the emergency talk group displayed
on their radio.
9.27.2
Receiving an Emergency Call
Initially, when receiving an emergency call, the radio sounds the emergency tone (three short highpitched tones).
The radio will flash “EMERGENCY” and display the alias of the user that triggered the emergency or the
alias of the talk group (if the incoming talk group is the selected talk group of the receiving radio).
With “None,” only the emergency tone is heard, not the initial open mic transmission.
To dismiss or ignore the emergency, refer to Section 9.27.3.
9.27.3
Dismissing an Emergency
The “Dismissing an Emergency” function allows you to “ignore” an emergency declared by another user.
An emergency is dismissed for a configurable amount of time (default = 5 minutes).
1. After receiving an emergency call, press the
2. Press the
or
button until you see “EmgDismiss.”
to toggle “<” on (dismiss) and off. This works in similar fashion to the lock out menu.
The emergency dismiss timer is cleared when the emergency is cleared.
9.27.4
Clearing an Emergency Call or Alert
Check with your system administrator to ensure that your radio is configured with the
ability to clear an emergency.
88
MM-013994-001, Rev. Ap1
1. Press to declare an emergency. To clear an emergency, press and hold Option 2 button . While
holding , press the emergency button. Release both buttons when the “emergency cleared” tone
sounds.
2. The radio returns to your default selected talk group. The “EMERGENCY” display is removed from
the main screen.
If the radio is in stealth mode, clearing the emergency will cause the radio to exit stealth
mode.
9.28
DYNAMIC REGROUPING
Dynamic regrouping requires that the network administrator determine which radio users should be
formed into an impromptu talk group to respond to particular emergency conditions.
The administrator will edit the personalities of the affected radios to include an emergency profile and
then page the affected radios to re-register with the network to receive their edited personalities.
In response, affected radios automatically re-register to receive their edited personalities. During reregistration, subscriber equipment will default to the emergency profile selected by the administrator.
9.29
GPS COORDINATES
The radio’s current latitude and longitude coordinates may be displayed using the “GPS” menu. The
following procedure assumes a GPS antenna is connected to the radio and it is receiving adequate signals
from GPS satellites.
or
until the “GPS” menu appears in the display. Current GPS coordinate latitude and
1. Press
longitude data continuously scrolls in the top line of the display in a degrees:minutes:seconds format.
2. Press
or
to change to another menu.
If the internal GPS receiver’s data is expired (30 minutes or more) or unavailable, the
radio uses the serving base station’s coordinates [GPS (Site) is displayed]. The GPS Menu
will also indicate if the data is aged (2 minutes or more) [GPS (Aged) is displayed].
9.30 V-TAC OPERATION
9.30.1 Extended Coverage Modes (“XCOV” and “XCOV-TG”)
In addition to all standard portable radio operating capabilities, Extended Coverage adds the V-TAC’s
bridging (vehicular repeat) functionality for accessing the OpenSky radio network. Each portable radio
connected to the V-TAC using Extended Coverage is considered a “client” on the V-TAC. Extended
Coverage benefits portable radio users since it allows them to get network connectivity using the
V-TAC’s higher transmit output power and better antenna system.
The V-TAC supports two Extended Coverage modes: Extended Coverage for individual users (display
reads “XCOV”) and Extended Coverage for a talk group (display reads “XCOV-TG”). Typically,
Extended Coverage is used after the vehicle’s operator has exited the vehicle with a portable radio unit
and the portable unit requires this bridging functionality to access the OpenSky radio network.
89
MM-013994-001, Rev. Ap1
The V-TAC takes advantage of OpenSky’s TDMA capability to eliminate interference between its local
and network radio links when operating in an Extended Coverage mode (XCOV or XCOV-TG), an
undesirable characteristic of many traditional vehicular repeater systems. Because the V-TAC employs
this technology, interference on the network and local radio links is minimized.
A V-TAC in XCOV or XCOV-TG mode sends its alias to clients. The alias is displayed in the second
line of the dwell menu of the client, (“VA ”). The client must be connected to a V-TAC running
version OTP14.4 or for the V-TAC to provide the alias to the client. If the client is connected to a
V-TAC running version OTP14.3.1 or earlier, the client displays “VA None.”
9.30.2
Change Between Extended Coverage Modes
By default, the specific Extended Coverage mode utilized, either XCOV or XCOV-TG, is determined by
commands sent to the V-TAC and portable radios from the system administrator or radio installation
personnel. In other words, these commands determine which Extended Coverage mode the V-TAC and
radios normally use and determine the access method that must be employed by a portable radio to
connect to the V-TAC. After commands of this type are sent to the V-TAC and portable radios, each must
be rebooted (powered off and then back on) before the change takes effect.
A radio can manually override this command-determined default mode by entering *61# or *62# or by
using the Client Mode menu option. Command *61# sets the radio to use the XCOV mode and *62# sets
the radio to use the XCOV-TG mode. However, the connection will only be successful if the V-TAC
operating mode matches the manually selected portable V-TAC mode.
9.30.3
Radio Limitations Using Extended Coverage Modes
Connecting a portable radio to a V-TAC introduces minor functional limitations. See the following
sections for a listing.
9.30.3.1 Limitations Using Both XCOV and XCOV-TG
Portable radios connected to the V-TAC using either of the Extended Coverage Modes, XCOV or
XCOV-TG, will not channel-scan unless they lose radio frequency contact with the V-TAC. If manually
enabled, radios will not scan network channels.
9.30.3.2 Limitations Using XCOV-TG
The following portable radio keypad functions are disabled when the radio is connected to the V-TAC
using the XCOV-TG mode: log-off, manual log-in, alerts, selective calls, PSTN calls, and speed dial
calls.
The following portable radio menus are disabled when the radio is connected to the V-TAC using the
XCOV-TG mode: alert destination, alert message, alert received, priority talk group, and scan mode. In
addition, the user cannot change talk group or profile.
9.30.4
Use XCOV Mode
The Extended Coverage for individual users (XCOV) mode allows up to eight (8) client radios to connect
to the V-TAC. The radios have full radio functionality including selective calling and mobile data.
With the Extended Coverage for individual users’ (XCOV) mode, V-TAC configuration defines which
portable radios are permitted V-TAC access. The radio will automatically connect to a V-TAC if it
cannot find a network channel. The radio can also be manually connected to a V-TAC as indicated with
the *61# and *62# commands, each determined by the system administrator in the radio configuration.
90
MM-013994-001, Rev. Ap1
9.30.4.1 Manually Accessing the XCOV Mode
P7370 Model Radios
1. Press *61# to manually access XCOV mode.
2. Press *60# to disconnect from XCOV mode.
All P7300 Model Radios
1. Press
2. Press
or
or
until the Client Mode menu appears.
until XCOV is displayed.
to confirm mode selection. The radio reverts to the dwell display and the V-TAC icon is
3. Press
displayed.
9.30.5
Use XCOV-TG Mode
When using the XCOV-TG mode, up to thirty (30) client radios can connect to the V-TAC. However,
unlike XCOV, radios connected using XCOV-TG are limited to communicating only on the XCOV-TG
talk group and emergency communications. Advanced features such as selective calling and mobile data
operations are not available to the XCOV-TG connected clients.
The talk group used for XCOV-TG communications is the talk group that was selected at the V-TAC
when it entered XCOV-TG mode. Before a radio can connect to the V-TAC, the talk group must be
selected on the P7300. If this talk group is not provisioned in the radio’s personality, the radio cannot
connect to the V-TAC via the XCOV-TG mode. While connected to the V-TAC via XCOV-TG, a
different talk group or profile cannot be selected.
When a portable radio is connected to the V-TAC via XCOV-TG, the V-TAC forwards only the network
voice traffic on the XCOV-TG talk groups.
9.30.5.1 Manually Accessing the XCOV-TG Mode
For the Extended Coverage for a talk group mode (XCOV-TG), a portable radio user is granted access
and connects to the V-TAC by simply selecting the same Talk Group that the V-TAC had selected when
it entered the XCOV-TG mode. Contact the system administrator for questions regarding these aspects.
During XCOV-TG mode operations, the V-TAC will not disconnect portable radios connected to it. A
portable radio user must manually disconnect from the V-TAC by pressing *60 # on the radio’s keypad.
However, if the V-TAC is switched out of the XCOV-TG mode, all portable radios will be automatically
disconnected from the V-TAC. The radios will continue to look for another V-TAC until manually
disconnected (*60#).
P7370 Model Radios
•
Press *62# to manually access XCOV-TG mode.
•
Press *60# to manually disconnect XCOV-TG mode.
All P7300 Model Radios
1. Press
2. Press
or
or
until the Client Mode menu appears.
until XCOV-TG is displayed.
to confirm mode selection. The radio reverts to the dwell display and the V-TAC icon is
3. Press
displayed.
91
MM-013994-001, Rev. Ap1
9.30.6
Use Scene-of-Incident Mode
The Scene-of-Incident mode (SOI) is user-selectable. The SOI mode provides a local repeater function
(V-TAC) with no network connection.
CAUTION
When operating in the SOI mode, the radio is disconnected from the OpenSky network.
Therefore, communications with radios and dispatch personnel on the network is not
possible.
SOI Mode, Manual Channel Entry (P7370 Model Only)
1. Press *4#.
2. The radio prompts for the channel. Enter the channel number and press
to confirm channel.
3. The radio prompts for the band. Table 9-10 lists valid bands and their definitions. Enter the number
to confirm.
assigned for the desired frequency band and press
4. The radio reverts to the dwell display. If accepted, you will be switched off the network, and be
communicating locally through the V-TAC.
or
or use the Client Mode menu to return to normal
Press *40#
operation (Network Mode). The personality and profile in use at the time the radio entered SOI mode is
restored.
SOI Mode, Manual Channel Entry (All P7300 Models)
1. Press
2. Press
3. Press
4. Press
or
or
until the Client Mode menu appears.
until SOI is displayed.
to confirm mode selection.
or
until “Manual Select Chan” is displayed and press
5. Press or to edit the right-most digit and press
desired channel is entered.
to advance to the next digit. Repeat until the
6. The radio then prompts the user to edit the band. Table 9-10 lists valid bands and their definitions.
to confirm and enter
Press or to edit the number assigned to the frequency band and press
the SOI mode.
Use the Client Mode menu to return to normal operation (Network Mode). The personality and profile in
use at the time the radio entered SOI mode is restored.
SOI Mode, Pre-Programmed Channel Selection (All P7300 Models)
1. Press
2. Press
3. Press
4. Press
5. Press
or
or
until the Client Mode menu appears.
until SOI is displayed.
to confirm mode selection.
or
scroll through a list of pre-programmed channels.
to confirm channel and enter SOI mode.
Use the Client Mode menu to return to normal operation (Network Mode). The personality and profile in
use at the time the radio entered SOI mode is restored.
92
MM-013994-001, Rev. Ap1
Table 9-10: Band Definitions
RF BAND
RF CHANNEL NUMBER
0 = SMR
Band 0: 1-830
1 = AMPS
Band 1: 1-600
2 = BORDER
Band 2: 1-600
3 = 700 MHz Band 1
Band 3: 1-477
4 = 700 MHz Band 2
Band 4: 481-957
5 = 700 MHz Band 3
Band 5: 1-477
6 = 700 MHz Band 4
Band 6: 481-957
7 = 900 MHz
Band 7: 1-399
8 = 800 MHz Rebanded
Band 8: 1-830
9 = 400 MHz T band WB
Band 9: 1-6718
(Independent Separation Between TX and RX)
10 = 400 MHz T band NB
Band 10: 1-6718
(Independent Separation Between TX and RX)
11 = 400 MHz T band Temp (NYPD only)
Band 11: 1-120
14 = 700 MHz reband WB
Band 14: 1-957
15 = 700 MHz reband NB
Band 15: 1-959
93
MM-013994-001, Rev. Ap1
CONVENTIONAL OPERATION
94
MM-013994-001, Rev. Ap1
10 CONVENTIONAL OPERATION
The radio functions in the conventional mode when using conventional communications channels (nontrunked).
10.1
CONTROLS
The radio features two rotary control knobs and an emergency button mounted on the top of the radio.
Push-To-Talk and option buttons are mounted on the side. The front mounted keypad has six buttons on
the P7350 Scan model and 15 buttons on the P7370 System model.
Figure 10-1: Top View
Figure 10-2: Side View
95
MM-013994-001, Rev. Ap1
10.1.1
Buttons and Knobs
This section describes the primary function of the button and knob controls. Refer to Figure 10-1 and
Figure 10-2.
POWER ON/OFF-VOLUME
CONTROL KNOB
Applies power to and adjusts the receiver’s volume. Rotating the
control clockwise applies power to the radio. A single alert tone (if
enabled through programming) indicates the radio is operational.
Rotating the control clockwise increases the volume level. Minimum
volume levels may be programmed into the radio to prevent missed
calls due to a low volume setting. While adjusting the volume the
display will momentarily indicate the volume level (i.e. VOL=31).
The volume range is from a minimum programmed level of zero
(displayed as OFF in the display) up to 40, which is the loudest level.
SYSTEM/GROUP/CHANNEL
CONTROL KNOB
Selects pre-programmed channels. This is a 16-position rotary knob.
EMERGENCY/HOME BUTTON
Automatically selects the pre-programmed Group/System by pressing
and holding for a programmed duration. It can also be used to declare
an emergency by pressing and holding for a programmed duration.
The button must be pre-programmed for either operation, but not both.
PTT BUTTON
PTT must be pressed before voice transmission begins.
OPTION BUTTON
Activates one of a number of programmable software options selected
during PC programming. Programmable options include hi/low power
settings, keypad lock, LCD contrast, and LCD and keypad back
lighting.
CLEAR/MONITOR BUTTON
Unsquelches the receiver and allows channel monitoring prior to
transmission. Momentarily removes the Receiver Channel Guard
decoding from the channel.
(OPTION BUTTON 2)
96
Note: A mechanical stop, which can limit the positions accessed, is
shipped with the radio but must be installed. To install the mechanical
stop, remove the System/Group/Channel control knob, loosen the set
screw on the System/Group/Channel control knob metal base (using a
1.27mm hex wrench), and remove the System/Group/Channel control
knob metal base. Replace the 16 channel ring with the channel stop
ring
located
at
the
desired
channel.
Re-install
the
System/Group/Channel control knob metal base, tighten the set screw,
and re-install the System/Group/Channel control knob.
MM-013994-001, Rev. Ap1
10.1.2
Keypad
The keys on the keypad have special functions and are labeled using a symbol or abbreviated word
describing its primary function. Numeric entry is a secondary function of the keys. Each key is described
in the following subsections.
Figure 10-3: P7350 “Scan” Radio Front Panel
KEY
FUNCTION
Primary Function: Allows the user to scroll through available systems, groups, or channels, depending on
personality programming.
Secondary Function: Changes the selection for an item within a list.
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within a list. This is similar to an “Enter” key.
Adds/Deletes selected groups or channels from the Scan list of the currently selected system.
Turns the Scan operation ON and OFF.
Activates one of a number of pre-programmed software options.
97
MM-013994-001, Rev. Ap1
Figure 10-4: P7370 “System” Radio Front Panel
KEY
FUNCTION
Primary Function: Allows the user to scroll through available systems, groups, or channels, depending on
personality programming.
Secondary Function: Changes the selection for an item within a list.
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within a list. This is similar to an “Enter” key.
Primary Function: Refer to the separate key definitions within this table.
Secondary Function: These keys function much as a typical DTMF telephone pad 0-9, *, and # keys; and are
used to place telephone interconnect calls and individual unit-to-unit calls.
Selects a specific system. If the rotary knob is programmed to select the system and more than 16 systems are
programmed in the radio, the
key is used to select additional banks (groupings) of systems.
Selects a specific group.
Turns the Scan operation ON and OFF.
Adds groups or channels from the currently selected system to the Scan list.
Deletes selected groups or channels of the currently selected system from the Scan list.
Places telephone interconnect calls.
Initiates individual calls.
98
MM-013994-001, Rev. Ap1
10.2
DISPLAY
The radio display is made up of 3 lines (see Figure 10-5). Lines 1 and 2 contain eight alphanumeric
character blocks and are used primarily to display system or group/channel names. Line 1 also displays
radio status messages. The 3rd line is used primarily to display radio status icons. All three lines are used
to display menu options when in the menu mode. If programmed, the display backlighting will illuminate
upon power up or when radio controls are operated.
Figure 10-5: P7300 Radio Display
99
MM-013994-001, Rev. Ap1
10.2.1
Radio Status Icons
Status Icons indicate the various operating characteristics of the radio. The icons show operating modes
and conditions and appear on the third line of the display (see Table 10-1).
Table 10-1: Status Icon Descriptions
CONVENTIONAL STATUS ICONS
st
Steady – during all radio transmissions. Appears in the 1 position of the display.
nd
Steady – “Busy” transmitting or receiving. Appears in the 2 position of the display.
Flashing – call queued.
rd
Steady – T99 Mode enabled. Appears in the 3 position of the display.
th
Steady – Channel Guard enabled. Appears in the 4 position of the display.
If icon is not visible – Channel Guard is disabled.
th
Steady – transmit at low power. Appears in the 5 position of the display.
If icon is not visible – transmit at high power.
th
Steady – transmit in encrypt mode. Appears in the 6 position of the display.
Flashing – receiving an encrypted call.
th
Steady – Indicates the current channel is set up as an analog channel. Appears in the 7 position of
the display.
th
Animated (rotates clockwise) – scan mode enabled. Appears in the 9 position of the display.
If icon is not visible – scan is disabled.
th
Steady – priority 1 group or channel. Appears in the 10 position of the display.
th
Steady – priority 2 group or channel. Appears in the 10 position of the display.
th
Steady – group or channel in scan list. Appears in the 10 position of the display.
th
Steady – special call mode (individual or telephone). Appears in the 11 position of the display.
th
Steady – battery charge indicators. Appear in the 12 position of the display.
Flashing – Low battery indicator.
Figure 10-6: Battery Charge Icons (Full Cycle)
The battery icons (see Figure 10-6) indicate approximate level only, based on battery voltage.
100
MM-013994-001, Rev. Ap1
10.3
TRI-COLOR LED
Figure 10-7: Tri-Color LED
The Tri-Color LED changes color to indicate radio status and is visible from both the front and top of the
radio (see Figure 10-7). The colors of the LED and the status they represent are:
10.4
Green:
Receiving
Red:
Transmitting Unencrypted
Orange:
Transmitting Encrypted
STATUS MESSAGES
During radio operation, various radio Status Messages can be displayed. The messages are described
below.
MESSAGE
NAME
DESCRIPTION
TALKARND
Talkaround
Indicates the radio is operating on conventional channels in talkaround
mode (no repeater).
LOW BATT
Low Battery
Battery voltage has dropped to the point to where the radio is no longer
able to transmit. The radio will still receive calls until the battery is
discharged beyond the point of operation at which time the radio will
automatically shutdown.
VOL=31
Volume Level
Indicates the current volume level. The volume level display ranges
from OFF (silent) to 40 (loudest).
101
MM-013994-001, Rev. Ap1
10.4.1
Error Messages
If either of the Error Messages shown below is displayed, the radio is programmed incorrectly or needs
servicing.
DSP ERR
ERR=XXXX
or
DIG V
ERR
(PowerUp
only)
Where: xxxx is the error code and DSP ERR or DIG V ERR is the message.
10.5
ALERT TONES
The P7300 radio provides audible Alert Tones or “beeps” to indicate the various operating conditions (see
Table 10-2).
Table 10-2: Alert Tones
NAME
TONE
DESCRIPTION
Call Originate
one short mid-pitched
OK to talk after pressing the push-to-talk button
Carrier Control Timer
five high-pitched/one long low-pitched
PTT depressed for maximum length of time
Low Battery
one low-pitched/one short mid-pitched
Low battery
TX Low Battery Alert
one low-pitched
After PTT - battery too low to transmit
10.6
TURNING ON THE RADIO
1. Power ON the radio by rotating the POWER ON-OFF/VOLUME knob clockwise. A short alert
signal (if enabled through programming) indicates the radio is ready to use.
2. The display shows the last selected system and group/channel or a default system and group/channel
(depending on programming).
3. Adjust the POWER ON-OFF/VOLUME knob to the desired volume level.
4. Select the desired system, group/channel. The display indicates the current system and group/channel
names.
5. The radio is now ready to transmit and receive calls.
10.7
102
SYSTEM SELECTION
METHOD 1:
From the control knob: If system selection is programmed to the
System/Group/Channel control knob, select a system by turning the knob to the
desired number position (1-16). The display registers the new system name on line
one. The button can be programmed to provide access to a “2nd bank” of 16 system
number positions (17-32).
METHOD 2:
From the keypad: If system selection is programmed as the primary function of
and
, select a system by pressing
or
to scroll through the system list. The
display registers the new system name on line one.
MM-013994-001, Rev. Ap1
METHOD 3:
(P7370 model radios only) Direct Access: Press
to enter the system select mode.
Press the numeric key, which is mapped to the desired system. Press
. The radio
will move to the selected system.
If system selection is programmed to the System/Group/Channel control knob, direct
access to systems will not be available. Pressing
or
will scroll through different
sets of 16 systems each (banks) if more than 16 systems are programmed into the radio.
The systems within each bank are then selectable via the System/Group/Channel control
knob as described previously in METHOD 1.
Example:
System: 1 = North
2 = South
3 = East
4 = West
10.8
Group: 1 = Group 1
2 = Group 2
3 = Group 3
4 = Group 4
1. Press
. (South is the currently selected system.)
2. Press
. (Press 4 to select the “West” system.)
3. Press
. (West is the newly selected system.)
GROUP/CHANNEL SELECTION
Several methods can be used to select a new group/channel.
10.9
METHOD 1:
From the Control knob: If group selection is programmed to the System/Group/Channel
control knob, select a group by turning the System/Group/Channel control knob to the
desired group number position. The display registers the new group name on line two.
If the knob is moved to a position greater than the number of programmed group, the
highest programmed group will remain selected. The button can be programmed to
provide access to a “2nd bank” of 16 group number positions (17-32)
METHOD 2:
and
From the keypad: If group selection is programmed as the primary function of
, select a group by pressing
or
to scroll through the list. The display
registers the new group name on line two.
METHOD 3:
(P7370 model radios only) Direct Access: Press
to enter the group select mode.
Press the numeric key mapped to the desired group. Press
. The radio will move to
the selected group.
MODIFY SCAN LIST
10.9.1
1. Press
P7370 Model
to toggle scan OFF and verify
is not displayed.
2. Select group or channel.
3. Press
once to remove group or channel from list.
4. Press
once to add as a normal group or channel.
5. Press
twice to add as a Priority 2 group or channel.
103
MM-013994-001, Rev. Ap1
6. Press
three times to add as a Priority 1 group or channel.
7. Press
to re-start scanning.
10.9.2
P7350 Model
1. Press
to toggle scan OFF and verify
is not displayed.
2. Select group or channel.
10.10
3. Press
once to remove group or channel from the list.
4. Press
once to add as a normal group or channel.
5. Press
twice to add as a Priority 2 group or channel.
6. Press
three times to add as a Priority 1 group or channel.
7. Press
to re-start scanning.
NUISANCE DELETE
A channel can temporarily be deleted from the scan list, if it is not the currently selected channel, by
pressing the
key (P7350 model) or the
key (P7370 model) during scan operation while the radio
is displaying the unwanted channel. The channel will be deleted from the scan list in the same manner as
if done using the steps above. Deletions done in this manner will not remain deleted if the radio is
powered OFF and then powered ON.
10.11
MENU
The Menu function accesses features that are not available directly from the keypad. The order and actual
menu items available is configurable through programming. At radio power up, the menu item that is at
the top of the menu list will always be displayed first. Subsequent access to the menu function will return
the last menu item that was shown in the display and cursor position.
1. To enter the menu mode, press the
key.
2. Upon entering the menu selection mode, Menu options will appear in the display (see Figure 10-8).
Figure 10-8: Menu Display
3. The radio will continue to receive and transmit normally while in the menu function.
or
4. To scroll through the menu options use the
found align the cursor with the option then press
shown in the display can now be changed by using
values.
5. Once the desired setting is reached press
level.
keys. When the required menu item has been
to select it. The menu item's parameter setting
or
to scroll through the list of parameter
to store the value and return the menu option selection
or
6. For menu items that display radio information, pressing
informational displays. Possible menu items are listed in Table 10-3.
104
will scroll through a list of
MM-013994-001, Rev. Ap1
An example of the backlight menu item selection process and menu item parameter change is shown in
Figure 10-9.
1. Press
to enter the menu mode.
2. Press
or
until the display shows:
Figure 10-9: Backlight Menu Item Parameter
3. Press
. The backlight menu item is activated. Line one shows the active menu item and its
current parameter setting. Line two shows the currently selected system or group name (see Figure
10-10).
Figure 10-10: Backlight Menu Display
4. The menu item's parameter setting shown in the display can now be changed by using
5. Once the desired setting is reached press
level.
or
to store the value and return the menu option selection
or
will scroll through a list of
For menu items that display radio information, pressing
informational displays. An example of information displays is shown in Table 10-4.
The TX POWER menu item, when selected, toggles LOW/HIGH power. It does not use
or
to scroll nor is an additional press of the
button required.
105
MM-013994-001, Rev. Ap1
Table 10-3: Menu Item Information
FEATURE
DISPLAY
PARAMETER
SETTING
COMMENT
Keypad Lock
Menu Item:
KEY LOCK
Once Selected:
LOCKED
Locked
Unlocked
Locks the keypad. To unlock; press and release
then within 1
second press the option button (NOTE: this sequence is also a short cut
to locking the keypad.)
Backlight Adjust
Menu Item:
BCK LIGHT
Once Selected:
BCKL=
OFF, 1 thru 6
Selects the light level for backlighting.
Contrast Adjust
Menu Item:
CONTRAST
Once Selected:
CNTRST=
Menu Item:
TX POWER
Once Selected:
POWER=
1, 2, 3, 4
Selects the display contrast level.
HIGH or LOW
Selects radio output power mode.
Radio Revision
Information
Toggle Scan On/Off
Display Current Home
Group/Channel
Menu Item:
REVISION
SCAN
HOME
N/A
ON/OFF
N/A
Selects the information display to view. Informational display only (see
Table 10-4). No user selectable settings.
Toggles Scan operation ON/OFF.
Selects Home Group/Channel
Select Desired System
Add Group/Channel to
Scan List
Delete Group/Channel
SYS SEL
SCAN ADD
N/A
N/A
Selects a new system.
Adds to Scan List.
Transmit Power Select
Add/Delete Scan List
Talkaround
Select Channel
Feature Encryption
Display
106
SCAN DEL
N/A
Deletes Group or Channel from Scan List.
SCAN A/D
TALKARND
CHN SEL
Menu Item:
FEATURES
Once Selected:
(See Feature
Encryption Display
Section)
N/A
ON/OFF
N/A
N/A
Add or Delete from Scan List.
Toggles Talkaround feature ON/OFF.
Conventional Only.
Indicates current features programmed into the radio as well as certain
information required to add features to the radio. Informational display
only. No user selectable settings.
MM-013994-001, Rev. Ap1
Table 10-4: Information Display
RADIO ID
XXXXXXXX
LID in EDACS/EA. In CONV it has no
meaning.
RAM SIZ
RAM Size
FLSH SIZ
Flash Size
RF BAND
Frequency Band
PERS VER
Software Version
DSP DATE
Date DSP code was built.
DSP TIME
DSP FEAT
DSP VER
Time DSP code was built.
The DSP Features supported by the
DSP code, in Hexadecimal.
Bit mapped (see IPC spec for details):
• 0x0001 – Conventional
• 0x0002 – EDACS
• 0x0010 – AMPF
• 0x0020 – undefined
DSP Software Version
FLSH VER
FLASH Software
ex: P73U0102
P=portable, 54=5400 radio,
U=unencrypted, 01=major revision (>50
means unreleased code), 02=minor
revision
HARRIS
(C) 2009
10.12
10.13
10.14
Copyright
PERSNLTY
Personality Name
BLD DATE
Date host (ARM) code was built.
BLD TIME
Time host (ARM) code was built.
BACKLIGHT ADJUST
1. Press
to access the menu.
2. Press
or
3. Press
to select Backlight menu.
4. Press
or
5. Press
to select new backlight setting.
to scroll through menu until “BCKLGHT” appears.
to scroll through available settings OFF, 1 through 6.
CONTRAST ADJUST
1. Press
to access the menu.
2. Press
or
3. Press
to select Contrast menu.
4. Press
or
5. Press
to select new contrast setting.
to scroll through menu until “CONTRAST” appears.
to adjust contrast setting from 1 - 4.
DECLARING AN EMERGENCY
1. Press and hold the red Emergency/Home button (the length of time is programmable; check with the
system administrator).
107
MM-013994-001, Rev. Ap1
2. *TXEMER* will flash in the display, plus
transmit icon
and
will be displayed. After 2-3 seconds the
will turn off.
3. *TXEMER* and
will remain until the emergency is cleared. (Refer to Section 8.21 for more
detail concerning emergency operation.)
4. Press the PTT and
will reappear.
5. Release PTT when the transmission is complete.
10.15
LOCKING/UNLOCKING KEYPAD
1. Press
button.
2. Within 1 second, press the Option button on the side of the radio.
10.16
HIGH/LOW POWER ADJUSTMENT
Transmit power adjustment is possible if enabled through programming. Within conventional systems,
transmit power is adjustable on a per channel basis. Within EDACS trunking systems, transmit power is
adjustable on a per system basis.
There are two ways to toggle between high and low power:
Using the Menu Button:
1. Press
2. Using the
display.
3. Press
or
key, scroll until the cursor (>) appears to the left of “TX POWER” in the
again to toggle between High and Low power.
4. “POWER = HIGH” or “POWER = LOW” will appear momentarily on the top line of the display.
Using the Pre-Programmed Option Button:
Press the Option button. “POWER = HIGH” or “POWER = LOW” will appear momentarily on the top
line of the display.
10.17
DIGITAL VOICE OPERATION
Digital voice programmed systems have three (3) different voice modes: clear (analog), digital, and
private (encrypted). The voice modes are programmed on a per-group basis within each trunked system
and on a per-channel basis within each conventional system.
10.17.1 Clear Mode
The Clear Mode is a voice mode in which the radio transmits and receives only clear (analog) voice
signals. These analog signals are non-digitized. Clear mode transmissions can be monitored easily by
unauthorized persons.
Groups or channels programmed for clear operation cannot transmit or receive digital
messages.
108
MM-013994-001, Rev. Ap1
10.17.2 Digital Mode
The Digital Mode allows the radio to transmit and receive digitized voice signals. Digital signals provide
improved weak signal performance and cannot be easily monitored with a standard receiver. Groups and
channels programmed for digital operation transmit only digital signals. Individual phone calls (I-Calls)
are answered back in the mode in which they were received assuming the call or hang time is still active.
Individual phone, all call, and emergency calls are transmitted clear if the digital mode is disabled or
inoperative.
1. If receiving an analog message trunked call, the radio responds in the analog mode during the
hang time on the working channel.
2. If receiving an analog I-Call, the radio responds in the analog mode during the hang time.
3. When using the *WHC* feature to respond to an I-Call (after the hang time has expired), the call
is transmitted in the mode defined by the system mode as programmed for the current system if
the ID being called is not in the I-Call list. If the ID is in the I-Call list, then the call is transmitted
as defined by the I-Call mode programmed in the list for that ID.
The overdial DTMF tones are not available while in the Digital Mode.
10.17.2.1 Scanned Group Calls
Receiving a Scanned Group Call is the same as receiving a selected group call. During the scan hang
time, if the radio was programmed for auto-select, it will transmit back in the same mode it received the
call. For example, if a clear group is entered in the scan list, it will only receive clear calls. If the same
group was available in digital and entered in the scan list, it can receive clear and digital calls, provided
auto-select was programmed in the radio. The user can choose to transmit on the scanned or selected
group. If a group is entered in the scan list more than once under different modes (clear and digital), only
the first occurrence of the group will be used.
Table 10-5: Transmit/Receive Mode Compatibility for Digital Voice Operation
GROUP/CHANNEL PROGRAMMING
(TRANSMIT)
CLEAR
RECEIVE
DIGITAL
RECEIVE
CLEAR
Yes
No
DIGITAL
Yes
Yes
Conventional digital channels require Channel Guard on the channel to operate
correctly.
The voice coding technology embodied in this product is protected by intellectual
property rights including patent rights, copyrights, and trade secrets of Digital Voice
Systems, Inc. The user of this technology is explicitly prohibited from attempting to
decompile, reverse engineer, or disassemble the Object Code, or in any other way
convert the Object Code into human-readable form.
10.18
RECEIVING A CALL
1. Select the desired conventional system/channel or turn scan ON and make sure desired channel is in
scan list.
109
MM-013994-001, Rev. Ap1
2. When the radio receives a call, the radio will unmute and the channel name will appear in the display.
10.19
SENDING A CALL
1. Select desired system/channel.
2. Ensure the channel is not busy by pressing the
icon is on, the channel is busy.
button momentarily. If audio is heard or if the
3. When you’re sure that the channel is not busy, press the PTT button and speak into the microphone.
110
MM-013994-001, Rev. Ap1
This page intentionally left blank
111
MM-013994-001, Rev. Ap1
P25 OPERATION
112
MM-013994-001, Rev. Ap1
11 P25 OPERATION
Once a P25 system has been selected from the available systems on your P7300 series portable radio, the
characteristics described in the following sections will govern operation.
11.1
CONTROLS
The radio features two rotary control knobs and an emergency button mounted on the top of the radio.
Push-To-Talk and option buttons are mounted on the side. The front mounted keypad has six buttons on
the P7350 Scan model and 15 buttons on the P7370 System Radio.
Figure 11-1: Top View
Figure 11-2: Side View
113
MM-013994-001, Rev. Ap1
11.1.1
Buttons and Knobs
This section describes the primary function of the button and knob controls. Refer to Figure 11-1 and
Figure 11-2.
POWER ON/OFF-VOLUME
CONTROL KNOB
Applies power to and adjusts the receiver’s volume. Rotating the
control clockwise applies power to the radio. A single alert tone (if
enabled through programming) indicates the radio is operational.
Rotating the control clockwise increases the volume level. Minimum
volume levels may be programmed into the radio to prevent missed
calls due to a low volume setting. While adjusting the volume the
display will momentarily indicate the volume level (i.e. VOL=31). The
volume range is from a minimum programmed level of zero (displayed
as OFF in the display) up to 40, which is the loudest level.
SYSTEM/GROUP/CHANNEL
CONTROL KNOB
Selects systems or groups/channels (depending on programming). This
is a 16-position rotary knob.
Note: A mechanical stop, which can limit the positions accessed, is
shipped with the radio but must be installed. To install the mechanical
stop, remove the System/Group/Channel control knob, loosen the set
screw on the System/Group/Channel control knob metal base (using a
1.27 mm hex wrench), and remove the System/Group/Channel control
knob metal base. Replace the 16 channel ring with the channel stop
ring located at the desired channel.
Reinstall the
System/Group/Channel control knob metal base, tighten the set screw,
and reinstall the System/Group/Channel control knob.
EMERGENCY/HOME BUTTON Automatically selects the pre-programmed Group/System by pressing
and holding for a programmed duration. It can also be used to declare
an emergency by pressing and holding for a programmed duration. The
button must be pre-programmed for either operation, but not both.
114
PTT BUTTON
Push-To-Talk must be pressed before voice transmission begins. In
trunked mode the radio’s ID is transmitted upon depression of the PTT
button.
OPTION BUTTON
Activates one of a number of programmable software options selected
during PC programming. Programmable options include hi/low power
settings, keypad lock, LCD contrast, and LCD and keypad back
lighting.
CLEAR/MONITOR BUTTON
(OPTION BUTTON 2)
Unsquelches the receiver and allows channel monitoring prior to
transmission. Momentarily removes the Receiver Channel Guard
decoding from the channel.
MM-013994-001, Rev. Ap1
11.1.2
Keypad
The keys on the keypad have special functions and are labeled using a symbol or abbreviated word
describing its primary function. Alpha-numeric entry is a secondary function of the keys. Each key is
described in the following subsections.
Figure 11-3: P7350 “Scan” Radio Front Panel
Table 11-1: P7350 Keypad Functions
KEY
FUNCTION
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within the menu. This is similar to an “Enter”
key.
Scrolls thru available menu items.
Activates one of any programmable software options selected during the PC programming,
including: high/low TX power and talkaround.
Toggles SCAN operation ON and OFF.
Adds/Deletes selected groups or channels from SCAN list of the currently selected system.
115
MM-013994-001, Rev. Ap1
Figure 11-4: P7370 “System” Radio Front Panel
Table 11-2: P7370 “System” Keypad Functions
KEY
0-9,
and
FUNCTION
Primary Function: Accesses the pre-stored menu.
Secondary Function: Activates a selected item within the menu. This is similar to an “Enter”
key.
Primary Function: Allows the user to scroll through available systems, groups, or channels,
depending on personality programming.
Secondary Function: Changes the selection for an item within a list.
Primary Function: Refer to the separate key definitions within this table.
Secondary Function: These keys function much as a typical DTMF telephone pad 0-9, *, and #
keys; and are used to place telephone interconnect and individual (unit-to-unit) calls.
Selects a specific system. If the rotary knob is used to select the system and more than 16
key is used to select additional banks
systems are programmed in the radio, the
(groupings) of systems.
Selects a specific group.
Turns the Scan operation ON and OFF.
Enables or disables Private Mode for the system/group/channel displayed.
Adds groups or channels from the currently selected system to the Scan list.
Status. Access to the status list (0-9). The Status key permits the transmission of a preprogrammed status message to an EDACS site.
Message. Access to the message list (0-9). The Message key permits the transmission of a preprogrammed message to an EDACS site.
Deletes selected groups or channels of the currently selected system from the Scan list.
Initiates telephone interconnect calls.
Initiates individual unit-to-unit calls.
116
MM-013994-001, Rev. Ap1
11.2 DISPLAY
The radio display is made up of 3 lines (see Figure 11-5). Lines 1 and 2 contain eight alphanumeric
character blocks and are used primarily to display system and group names. Line 1 also displays radio
status messages. The 3rd line is used primarily to display radio status icons. All three lines are used to
display menu options when in the menu mode. If programmed, the display backlighting will illuminate
upon power up or when radio controls are operated.
Figure 11-5: P7300 Radio Display
117
MM-013994-001, Rev. Ap1
11.3
RADIO STATUS ICONS
Status Icons indicate the various operating characteristics of the radio. The icons show operating modes
and conditions and appear on the third line of the display (see Table 11-3).
Table 11-3: Radio Status Icon Descriptions
EDACS, CONVENTIONAL, AND P25 ICONS
st
Steady – during all radio transmissions. Appears in the 1 position of the display.
nd
Steady – “Busy” transmitting or receiving. Appears in the 2 position of the display.
Flashing – call queued.
rd
Steady – T99 Mode enabled. Appears in the 3 position of the display.
th
Steady – Channel Guard enabled. Appears in the 4 position of the display.
If icon is not visible – Channel Guard is disabled.
™
th
Steady – trunked system in Failsoft mode. Appears in the 4 position of the display.
th
Steady – transmit at low power. Appears in the 5 position of the display.
If icon is not visible – transmit at high power.
th
Steady – transmit in encrypt mode. Appears in the 6 position of the display.
Flashing – receiving an encrypted call.
th
Steady – Indicates the current channel is set up as a Project 25 (P25) channel. Appears in the 7 (and
th
8 ) positions of the display.
th
Steady – Indicates the current channel is set up as a ProVoice channel. Appears in the 7 position of
the display.
th
Steady – Indicates the current channel is set up as an analog channel. Appears in the 7 position of
the display.
th
Animated (rotates clockwise) – scan mode enabled. Appears in the 9 position of the display.
If icon is not visible – scan is disabled.
th
Steady – priority 1 group or channel. Appears in the 10 position of the display.
th
Steady – priority 2 group or channel. Appears in the 10 position of the display.
th
Steady – group or channel in scan list. Appears in the 10 position of the display.
th
Steady – special call mode (individual or telephone). Appears in the 11 position of the display.
th
Steady – battery charge indicators. Appear in the 12 position of the display.
Flashing – Low battery indicator.
118
MM-013994-001, Rev. Ap1
Figure 11-6: Full Cycle Battery Charge Indicator
The battery charge indicators illustrate approximate level only, based on battery voltage. Refer to Figure
11-6.
11.4
TRI-COLOR LED
Figure 11-7: Tri-Color LED
The Tri-Color LED changes color to indicate radio status and is visible from both the front and top of the
radio (see Figure 11-7). The colors of the LED and the status they represent while operating in EDACS
and P25 modes are defined below.
11.5
Green:
Receiving
Red:
Unencrypted transmission
Orange:
Encrypted transmission
STATUS MESSAGES
During radio operation, various radio Status Messages can be displayed. The messages are described
below.
MESSAGE
QUEUED
NAME
Call Queued
DESCRIPTION
Indicates the system has placed the call in a request queue.
SYS BUSY System Busy
Indicates the system is busy, no channels are currently available, the queue
is full, or an individual call is being attempted to a radio that is currently
transmitting.
DENIED
Indicates the radio or talkgroup is not authorized to operate on the selected
system and/or talkgroup.
Call Denied
119
MM-013994-001, Rev. Ap1
MESSAGE
NAME
DESCRIPTION
CC SCAN
Control
Indicates the control channel is lost and the radio has entered the Control
Channel Scan Channel Scan mode to search for the control channel (usually out of range
indication).
WA SCAN
Wide Area
Scan
Indicates the radio has entered the Wide Area Scan mode to search for a
new system (if enabled through programming).
SYSC ON
System Scan
Features On
Indicates the System Scan features are enabled.
SYSC OFF System Scan
Features Off
Indicates the System Scan features are disabled.
LOW BATT Low Battery
Battery voltage has dropped to the point to where the radio is no longer able
to transmit. The radio will still receive calls until the battery is discharged
beyond the point of operation at which time the radio automatically shuts
down.
RXEMER
Receive
Emergency
Indicates an emergency call is being received.
flashing on line two.
TXEMER
Transmit
Emergency
Indicates an emergency call has been transmitted on this radio.
message will be flashing on line two.
VOL=31
Volume Level Indicates the current volume level. The volume level display ranges from
OFF (silent) to 40 (loudest).
WHC
Who Has
Called
Indicates an individual call has been received, but not responded to. The
indicator turns OFF if the individual call mode is entered, the system is
changed, or the radio is turned off and then on again.
UNKNOWN
Unknown ID
Indicates an individual call is being received from an unknown ID.
11.5.1
This message will be
This
Error Messages
If either of the Error Messages shown below is displayed, the radio is programmed incorrectly or needs
servicing.
DSP ERR
ERR=XXXX
or
DIG V
ERR
(PowerUp
only)
Where: xxxx is the error code and DSP ERR or DIG V ERR is the message.
120
MM-013994-001, Rev. Ap1
11.6 ALERT TONES
The P7300 series radios provide audible Alert Tones or “beeps” to indicate the various operating
conditions (see Table 11-4).
Table 11-4: Alert Tones
NAME
TONE
DESCRIPTION
Call Originate
one short mid-pitched
OK to talk after pressing the push-to-talk button
Call Queued
one high-pitched
Call queued for processing
Autokey
one mid-pitched
Queued call received channel assignment
System Busy
three low-pitched
System busy or unable to complete call
Call Denied
one low-pitched
Radio is not authorized on the system or group
Carrier Control Timer
five high-pitched/one long low-pitched
PTT depressed for maximum length of time
Low Battery
one low-pitched/one short mid-pitched
Low battery
TX Low Battery Alert
one low-pitched
After PTT - battery too low to transmit
11.7 TURNING ON THE RADIO
1. Power ON the radio by rotating the POWER ON-OFF/VOLUME knob clockwise. A short alert
signal (if enabled through programming) indicates the radio is ready to use.
2. The display shows the last selected system and group or a default system and group (depending on
programming).
3. Adjust the POWER ON-OFF/VOLUME knob to the desired volume level.
4. Select the desired system and group. The display indicates the current system and group names.
5. The radio is now ready to transmit and receive calls.
11.8
SYSTEM SELECTION
METHOD 1:
From the Control knob: If system selection is programmed to the
System/Group/Channel control knob, select a system by turning the knob to
the desired system number position (1-16). The display registers the new
system name on line one. The
button can be programmed to provide
access to a “2nd bank” of 16 system number positions (17-32).
METHOD 2:
From the keypad: If system selection is programmed as the primary function
of
and
select a system by pressing
or
to scroll through the
system list. The display registers the new system name on line one.
METHOD 3:
to enter the system
(P7370 model radios only) Direct Access: Press
select mode. Press the numeric key, which is mapped to the desired system.
Press
. The radio will move to the selected system.
121
MM-013994-001, Rev. Ap1
If system selection is programmed to the System/Group/Channel control knob, direct
access to systems will not be available. Pressing
or
will scroll through
different sets of 16 systems each (banks) if more than 16 systems are programmed into
the radio.
The systems within each bank are then selectable via the
System/Group/Channel control knob as described previously in METHOD 1.
Example:
System: 1 = North
2 = South
3 = East
4 = West
Group: 1 = Group 1
2 = Group 2
3 = Group 3
4 = Group 4
1. Press
. (South is the currently selected system.)
2. Press
. (Press 4 to select “West” system.)
3. Press
. (West is the newly selected system.)
11.8.1
GROUP/CHANNEL SELECTION
Several methods can be used to select a new group or channel.
11.9
METHOD 1:
From the Control knob: If group selection is programmed to the System/Group/Channel
control knob, select a group by turning the System/Group/Channel control knob to the
desired group number position. The display registers the new group name on line two.
If the knob is moved to a position greater than the number of programmed groups, the
highest programmed group will remain selected. The button can be programmed to
provide access to a “2nd bank” of 16 group number positions (17-32).
METHOD 2:
and
From keypad: If group selection is programmed as the primary function of
select a group by pressing
or
to scroll through the group list. The display
registers the new group name on line two.
METHOD 3:
to enter the group select mode.
(P7370 model radios only) Direct Access: Press
. The radio will move to
Press the numeric key mapped to the desired group. Press
the selected group.
MODIFY SCAN LIST
11.9.1
1. Press
P7370 Model
to toggle scan OFF and verify
is not displayed.
2. Select group or channel.
122
3. Press
once to remove group from list.
4. Press
once to add as a normal group.
5. Press
twice to add as a Priority 2 group.
6. Press
three times to add as a Priority 1 group.
7. Press
to re-start scanning.
MM-013994-001, Rev. Ap1
11.9.2
P7350 Model
1. Press
to toggle scan OFF and verify
is not displayed.
2. Select group or channel.
11.10
3. Press
once to remove group from the list.
4. Press
once to add as a normal group.
5. Press
twice to add as a Priority 2 group.
6. Press
three times to add as a Priority 1 group.
7. Press
to re-start scanning.
MENU
The Menu function accesses features that are not available directly from the keypad. The order and actual
menu items available is configurable through programming. Upon radio power up, the menu item that is
at the top of the menu list will always be displayed first. Subsequent access to the menu function will
return the last menu item that was shown in the display and cursor position.
1. To enter the menu mode, press
2. Upon entering the menu selection mode, Menu options will appear in the display (see Figure 11-8).
Figure 11-8: Menu Display
3. The radio will continue to receive and transmit normally while in the menu function.
or
4. To scroll through the menu options use the
found align the cursor with the option then press
shown in the display can now be changed by using
values.
5. Once the desired setting is reached press
level.
keys. When the required menu item has been
to select it. The menu item's parameter setting
or
to scroll through the list of parameter
to store the value and return the menu option selection
or
For menu items that display radio information, pressing
informational displays. Possible menu items are listed in Table 11-5.
will scroll through a list of
11.10.1 Menu Item Selection Process
An example of the backlight menu item selection process and menu item parameter change is shown in
Figure 11-9.
1. Press
. The menu mode is entered.
2. Press
or
until the display shows:
123
MM-013994-001, Rev. Ap1
Figure 11-9: Backlight Menu Item Selection Parameter
3. Press
. The backlight menu item is activated. Line one shows the active menu item and its
current parameter setting. Line two shows the currently selected system or group name (see Figure
11-10).
Figure 11-10: Backlight Menu Display
4. The menu item's parameter setting shown in the display can now be changed by using
5. Once the desired setting is reached press
level.
or
to store the value and return the menu option selection
or
will scroll through a list of
For menu items that display radio information pressing
informational displays. An example of information displays is shown in Table 11-6.
The TX POWER menu item, when selected, toggles LOW/HIGH power. It does not use
or
to scroll nor is an additional press of the
button required.
124
MM-013994-001, Rev. Ap1
Table 11-5: Menu Item Information
FEATURE
DISPLAY
PARAMETER
SETTING
Locked
Unlocked
COMMENT
Keypad Lock
Menu Item:
KEY LOCK
Once Selected:
LOCKED
Backlight Adjust
Menu Item:
BCK LIGHT
Once Selected:
BCKL=
OFF, 1 thru 6
Selects the light level for backlighting.
Contrast Adjust
Menu Item:
CONTRAST
Once Selected:
CNTRST=
1, 2, 3, 4
Selects the display contrast level.
Menu Item:
TX POWER
Once Selected:
POWER=
Radio Revision Information Menu Item:
REVISION
HIGH or LOW
Selects radio output power mode.
N/A
Toggle Scan On/Off
SCAN
Toggle Private Mode
PRIVATE
Display Current Encryption DISP KEY
Key
ON/OFF
ON/OFF
N/A
Display Current Home
Group/Channel
Select Desired System
Add Group/Channel to
Scan List
HOME
N/A
Selects the information display to view. Informational display only. No
user selectable settings.
Toggles Scan operation ON/OFF.
Toggles Private Mode ON/OFF.
Displays current encryption key. Informational display only. No
selectable settings.
Selects Home Group/Channel
SYS SEL
SCAN ADD
N/A
N/A
Selects a new system.
Adds to Scan List.
Delete Group/Channel
SCAN DEL
Add/Delete Scan List
SCAN A/D
Select Telephone
PHN CALL
Numbers From Phone List
N/A
N/A
N/A
Deletes Group or Channel from Scan List.
Add or Delete from Scan List.
Trunked Only.
Data Operation
Select Individual Call from
IC List
Select Group
Feature Encryption Display
NO DATA
IND CALL
ON/OFF
N/A
Trunked Only. Toggles Data Operation ON/OFF.
Trunked Only.
GRP SEL
Menu Item:
FEATURES
N/A
N/A
System Scan Enable
Menu Item:
ON/OFF
SYS SCAN
Once Selected:
SYSC ON or SYSC
OFF
Trunked Only.
Indicates current features programmed into the radio as well as certain
information required to add features to the radio. Informational display
only. No user selectable settings.
Toggles System Scan feature ON/OFF.
Transmit Power Select
Locks the keypad. To unlock; press and release
then within 1
second press the option button NOTE: This sequence is also a short
cut to locking the keypad.
125
MM-013994-001, Rev. Ap1
Table 11-6: Information Display
RADIO ID
XXXXXXXX
LID in EDACS/EA In CONV it has no
meaning.
RAM SIZ
RAM Size
FLSH SIZ
Flash Size
RF BAND
Frequency Band
PERS VER
Software Version
DSP DATE
Date DSP code was built.
DSP TIME
DSP FEAT
DSP VER
Time DSP code was built.
The DSP Features supported by the
DSP code, in Hexadecimal.
Bit mapped (see IPC spec for details):
• 0x0001 – Conventional
• 0x0002 – EDACS
• 0x0010 – AMPF
• 0x0020 – undefined
DSP Software Version
FLSH VER
FLASH Software
ex: P73U0102
P=portable, 54=5400 radio,
U=unencrypted, 01=major revision (>50
means unreleased code), 02=minor
revision
HARRIS
(C) 2009
11.11
11.12
11.13
Copyright
PERSNLTY
Personality Name
BLD DATE
Date host (ARM) code was built.
BLD TIME
Time host (ARM) code was built.
BACKLIGHT ADJUST
1. Press
to access the menu.
2. Press
or
3. Press
to select Backlight menu.
4. Press
or
5. Press
to select new backlight setting.
to scroll through menu until “BCKLGHT” appears.
to scroll through available settings OFF, 1 through 6.
CONTRAST ADJUST
1. Press
to access the menu.
2. Press
or
3. Press
to select Contrast menu.
4. Press
or
5. Press
to select new contrast setting.
to scroll through menu until “CONTRAST” appears.
to adjust contrast setting from 1 - 4.
DECLARING AN EMERGENCY
1. Press and hold the red Emergency/Home button (the length of time is programmable; check with the
system administrator).
126
MM-013994-001, Rev. Ap1
2. *TXEMER* will flash in the display, plus
transmit icon
and
will be displayed. After 2-3 seconds the
will turn off.
3. *TXEMER* and
will remain until the emergency is cleared. Refer to Section 11.19 for more
detail regarding emergency operation.
4. Press the PTT and
will reappear.
5. Release PTT when the transmission is complete.
11.14
LOCKING/UNLOCKING KEYPAD
1. Press
button.
2. Within 1 second, press the
11.15
button on the side of the radio.
HIGH/LOW POWER ADJUSTMENT
Transmit power adjustment is possible if enabled through programming. Within conventional systems,
transmit power is adjustable on a per channel basis. Within EDACS trunking systems, transmit power is
adjustable on a per system basis.
There are two ways to toggle between high and low power, described in Sections 11.15.1 and 11.15.2.
11.15.1 Using the Menu Button
1. Press
2. Using the
display.
3. Press
or
keys, scroll until the cursor (>) appears to the left of “TX POWER” in the
again to toggle between High and Low power.
4. “POWER = HIGH” or “POWER = LOW” will appear momentarily on the top line of the display.
11.15.2 Using the Pre-Programmed Option Button
Press the Option button. “POWER = HIGH” or “POWER = LOW” will appear momentarily on the top
line of the display.
11.16
DIGITAL VOICE OPERATION
Digital voice programmed systems have three (3) different voice modes: clear (analog), digital, and
private (encrypted). The voice modes are programmed on a per-group basis within each trunked system
and on a per-channel basis within each conventional system.
11.16.1 Clear Mode
The Clear Mode is a voice mode in which the radio transmits and receives only clear (analog) voice
signals. These analog signals are non-digitized and non-encrypted. Clear mode transmissions can be
monitored easily by unauthorized persons.
127
MM-013994-001, Rev. Ap1
Groups or channels programmed for clear operation cannot transmit or receive digital or
private messages.
11.16.2 Digital Mode
The Digital Mode allows the radio to transmit and receive digitized voice signals. Digital signals provide
improved weak signal performance and cannot be easily monitored with a standard receiver. Groups
programmed for digital operation transmit only digital signals. Message trunked group calls and
individual phone calls (I-Calls) are answered back in the mode in which they were received assuming the
call or hang time is still active. Individual phone, all call, and emergency calls are transmitted clear if the
digital mode is disabled or inoperative.
1. If receiving an analog message trunked call, the radio responds in the analog mode during the hang
time on the working channel.
2. If receiving an analog I-Call, the radio responds in the analog mode during the hang time.
3. When using the *WHC* feature to respond to an I-Call (after the hang time has expired), the call is
transmitted in the mode defined by the system mode as programmed for the current system if the ID
being called is not in the I-Call list. If the ID is in the I-Call list, then the call is transmitted as defined
by the I-Call mode programmed in the list for that ID.
The overdial DTMF tones are not available while in the Digital Mode.
11.16.3 Private Mode
The Private Mode allows the radio to transmit encrypted messages and receive clear or private
transmissions. The radio transmits private if the group is programmed for private operation and forced
operation is pre-programmed. If auto-select operation is pre-programmed and the radio is in the Private
Mode, the radio transmits in the mode of the received call if the hang time is active. If no hang time is
active, the radio transmits private.
Cryptographic keys are transferred to the radio using a cryptographic Keyloader. Up to seven (7)
different cryptographic keys, numbered 1-7, can be transferred from a Keyloader and stored in the radio.
An individual key is automatically selected on a per-group basis according to the radio programming.
Groups and channels within the digital system can be programmed for keys 1-7 (private). Up to 8 banks
of 7 keys can be stored for private systems. The bank is specified per system.
When operating on a group programmed for Private Mode, all transmissions are private transmissions and
the radio receives clear and private signals. The status icon is displayed when the Private Mode is
enabled. If the selected group is programmed for auto-select capability, the mode may be toggled
between private and clear with the
key, then following the selection mode rules. Radios programmed
for forced private operation do not allow a change of the transmit mode.
11.16.3.1 Displaying the Currently Used Cryptographic Key Number
To display the currently used Cryptographic Key Number for either the system encryption key (for
special call such as individual, phone, all, agency or fleet) or the group key (for group calls), perform the
following procedure:
1. Press the
2. Use the
128
button.
or
button to select "DISP KEY."
MM-013994-001, Rev. Ap1
3. Use the
or
button to toggle between displaying the system key (Figure 11-11) or the
group/channel key (Figure 11-12).
Figure 11-11: System Encryption Key Display
Figure 11-12: Group/Channel Encryption Key Display
11.16.3.2 Key Zero
All cryptographic keys can be zeroed (erased from radio memory) by pressing the button and while still
pressing this button, press and hold the OPTION button. Press both buttons for 2 seconds. A series of
beeps will begin at the start of the 2 second period and then switch to a solid tone after the keys have been
zeroed. The display will indicate KEY ZERO.
If the cryptographic key(s) are zeroed, one or more keys must be transferred from the Keyloader into the
radio before private communications may continue.
11.16.4 Private Operation
11.16.4.1 Receiving an Encrypted Call
When receiving, the radio automatically switches between clear or private operation. If the transmission
being received is an encrypted transmission, it will be decrypted, the icon is displayed, the receiver will
unsquelch and the message will be heard in the speaker. For this to occur, the selected group or channel
must be programmed for private operation and the correct cryptographic key must be loaded into the
radio.
11.16.4.2 Transmitting an Encrypted Call
1. Select the desired group or channel.
key; then follow the selection mode rules. On a
2. Place the radio in Private Mode by pressing
System radio, the
key can be used to toggle the Private Mode ON/OFF. When Private Mode is
enabled, the icon is displayed.
3. If the last state of the radio was Private Mode, the Private Mode will be enabled on power up. Also,
the Private Mode will be enabled if forced operation has been programmed in the radio.
If a group is not programmed for Private Mode operation, PVT DIS will be displayed if an attempt is
made to enable private transmit mode. It is not possible to operate on this group in Private Mode.
If the radio does not have the correct encryption key loaded, NO KEY# will be displayed and the call
will not be transmitted.
129
MM-013994-001, Rev. Ap1
4. Continue with standard transmission procedures. A Private Mode access tone will be heard when the
PTT button is pressed.
11.16.4.3 Scanned Group Calls
Receiving a Scanned Group Call is the same as receiving a selected group call. During the scan hang
time, if the radio was programmed for auto-select, it will transmit back in the same mode it received the
call. For example, if a clear group is entered in the scan list, it will only receive clear calls. If the same
group was available in private and entered in the scan list, it can receive clear and private calls, provided
auto-select was programmed in the radio. The user can select transmitting on the scanned or selected
group. If a group is entered in the scan list more than once, and in different modes (clear, digital, or
private), only the first occurrence of the group will be used.
Table 11-7: Transmit/Receive Mode Compatibility for Digital Voice Operation
GROUP
PROGRAMMING
(TRANSMIT)
CLEAR
RECEIVE
CLEAR
Yes
No
No
DIGITAL
PRIVATE
Yes
Yes
Yes
No
No
Yes*
DIGITAL
RECEIVE
PRIVATE
RECEIVE
*assumes the proper cryptographic key is loaded
Conventional digital or encrypted channels require Channel Guard on the channel to
operate correctly.
The voice coding technology embodied in this product is protected by intellectual
property rights including patent rights, copyrights, and trade secrets of Digital Voice
Systems, Inc. The user of this technology is explicitly prohibited from attempting to
de-compile, reverse engineer, or to disassemble the Object Code, or in any other way
convert the Object Code into a human-readable form.
11.17
SCANNING TRUNKED GROUPS
Groups that have been previously added to the scan list on a per system basis may be scanned. Each
system's group scan list is retained in memory when the radio is powered OFF or when the battery pack is
removed.
11.17.1 Turning Scan On and Off
1. Toggle Scan operation ON by pressing
clockwise to indicate radio is scanning.
(P7350 model) or
2. Toggle Scan operation OFF by again pressing
disappear.
•
130
(P7370 model). The
(P7350 model) or
icon rotates
(P7370 model). The
will
If the radio scans to a group other than the selected group then receives a call on the selected
group, the radio will switch to the selected group. However, if the “scanned-to” group is
programmed at a higher priority the radio will remain on the “scanned-to” group.
MM-013994-001, Rev. Ap1
•
The radio will continue scanning if a new group is selected when scan is ON.
3. Pressing the PTT button when scan is ON will cause the radio to transmit on the displayed group or to
the currently selected group (depending on programming).
11.17.2 Adding Groups to a Scan List
P7350 Model Radio
1. Scan must be OFF to add/delete groups to/from the scan list. If the Scan icon
key to turn Scan OFF.
is ON, press the
2. Select the desired group using the System/Group/Channel control knob and/or the
If the selected group is currently on the list, pressing
will display on line three.
or
3. If the scan list status icon is blank ( ), the group can be added to the scan list by pressing the
will be displayed on line three.
4. Press the
key a second time to set the group to Priority 2. A
keys.
key.
is displayed on line three.
a third time to set the group to Priority 1. A is displayed on line three. The priority level
5. Press
section sequence only advances the group to the next high priority level and stops at priority level 1.
To select a lower priority level, the group must be deleted from the scan list and then added back to
the scan list. Each new group added to the scan list starts at the lowest priority. If the Priority 1 and
Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously
assigned group will change to non-priority scanning. One of the following messages may be
momentarily displayed.
SCAN DIS
The radio is not programmed to scan.
FIXED P1
A Priority 1 group has been pre-programmed into the radio. A new Priority 1 group
cannot be selected.
FIXD LST
A fixed scan list has been pre-programmed into the radio. It is not possible to change
the list without reprogramming the radio.
To quickly view multiple group scan status, press
then slowly but consistently rotate
the group knob. Each group status will appear on the display.
P7370 Model Radio
1. With scan operation turned OFF, select the desired group to add to the selected trunked system group
scan list.
. The current priority status of the group will be displayed in column 10 of line three for a
2. Press
time-out period. If the group is not part of the scan list the status will be blank.
3. While the status is displayed, press
4. Press
to add the group to the scan list.
a second time to set the group to Priority 2. A
is displayed on line three.
is displayed on line three.
a third time to set the group to Priority 1. A is displayed on line three. The priority level
5. Press
selection sequence only advances the group to next higher priority level and stops at priority level 1.
131
MM-013994-001, Rev. Ap1
To select a lower priority level, the group must be deleted from the scan list and then added back to
the scan list. Each new group added to the scan list starts at the lowest priority. If the Priority 1 and
Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously
assigned group will change to non-priority scanning. One of the following messages may be
momentarily displayed.
SCAN DIS
The radio is not programmed to scan.
FIXED P1
A Priority 1 group has been pre-programmed into the radio. A new Priority 1 group
cannot be selected.
FIXD LST
A fixed scan list has been pre-programmed into the radio. It is not possible to change
the list without reprogramming the radio.
To quickly view multiple group scan status, press either
or the
key. Then
slowly but consistently rotate the group knob. Each group status will appear on the
display.
11.17.3 Deleting Groups from a Scan List
P7350 Model Radio
1. With scan operation turned OFF, select the desired group to delete from the selected trunked system
group scan list.
2. Press
. The current status of the group is displayed for a time-out period.
until the group from the scan list is "blank." The
3. While the current status is displayed, press
sequence is "blank," , , , "blank." Any group that is not in a trunked system group scan list will
show a "blank" for the time-out period when it is the selected channel.
P7370 Model Radio
1. With scan operation turned OFF, select the desired group to delete from the selected trunked system's
group scan list.
2. Press
. The current status of the group is displayed for a time-out period.
to delete the group from the scan list. , , or turns OFF.
3. While the status is displayed, press
Any group that is not in a trunked system group scan list will show a "blank" for the time out period
when it is the selected channel.
11.17.4 Nuisance Delete
A group can also be deleted from the scan list, if it is not the currently selected group, by pressing the
key (P7350 model) or the
key (P7370 model) during scan operation while the radio is displaying the
unwanted group. The group will be deleted from the system's group scan list in the same manner as if
done using the steps above. Deletions done in this manner will not remain deleted if the radio is powered
OFF and then powered ON.
11.18
SCANNING TRUNKED SYSTEMS
The radio can be programmed with the following System Scan features. These features are automatically
enabled when the radio is powered ON. A key or menu option is also defined to allow the System Scan
132
MM-013994-001, Rev. Ap1
features to be toggled during radio operation. The System Scan state will be maintained through system
changes but will default to ON when the radio is powered ON.
Enable/Disable via Menu Selection
Press
and then use the
or
buttons to scroll through the selections until SYS SCAN is
displayed. Then press
to toggle the System Scan state. The SYSC ON or SYSC OFF display
message is displayed for two seconds to show the new state.
Enable/Disable via Pre-Programmed Keypad Key
Press the key pre-programmed to toggle System Scan and the SYSC ON or SYSC OFF display message
is displayed for two seconds to show the new state.
11.18.1 Wide Area System Scanning
The P7300 series radio can be programmed for Wide Area System Scan operation for roaming across
mobile systems. Upon the loss of the currently selected system's control channel, radios can be
programmed to automatically scan the control channels of other systems. If a new control channel is
found, the radio will switch to the new system and sound an alert tone.
11.18.2 Priority System Scan
The radio can also be programmed for Priority System Scan. The priority system is the desired or
preferred system. While receiving the control channel of the selected system, the radio will periodically
leave the selected system and search for the control channel of the priority system. This is done at a
programmable rate defined by the value in the Priority Scan Time control (unless the ProScan™ algorithm
is enabled, as explained in the following sections). This priority scan timer is reset each time the PTT
button is pressed or when the call is received. If the priority system control channel is found, (or meets the
predefined criteria ), the radio will automatically switch to the priority system.
11.18.2.1 Enabling the Wide Area System Scan Function
If the radio cannot find the control channel of the selected system and begins to wide area system scan,
the radio will only scan for the priority system control channel if the priority system is in the wide area
scan list.
11.18.2.2 When ProScan is Enabled
The radio monitors the priority system and will switch to the priority system if the criteria defined by the
controls in the ProScan Options dialog box are met. If ProScan is enabled, the rate at which the radio will
scan for the priority system is defined by the System Sample Time control, located in the ProScan
Options dialog box. See Section 8.20.3 for more information on ProScan.
11.18.3 ProScan
The radio may be programmed for ProScan system scan operation for multi-site applications depending
on the version of radio flash code. ProScan is an improved multi-site system scanning algorithm designed
to replace ProSound™ scanning. ProScan provides the radio with the ability to select a new system for the
radio to communicate on, when the selected system drops below a predefined level. This is accomplished
by enabling each radio to analyze the signal quality of its current control channel and compares it with the
signal quality of the control channel for each site in its adjacent scan list. (The signal quality metric used
for the ProScan algorithm is based on a combination of both Received Signal Strength Indicator (RSSI)
and Control Channel Verification (CCV) measurements.) When the selected system degrades to a preprogrammed level, the radio will begin to look for a better control channel. Once a control channel that
133
MM-013994-001, Rev. Ap1
exceeds the pre-programmed parameters is found, the radio will change to the new system and emit a tone
(if enabled through programming). If the control channel is completely lost, the radio will enter Wide
Area System scanning and search the programmed adjacent systems until a suitable control channel is
found.
11.19
EMERGENCY OPERATION
The radio's ability to declare an emergency, clear an emergency, remain locked on an emergency system
and group, and the emergency audio and display freeze can each be enabled or disabled through
programming. When an emergency is declared scanning will stop and restarts only after the emergency
has been cleared.
11.19.1 Receiving an Emergency Call
When receiving an Emergency Call on the selected group and system, an alert beep is heard and is
displayed. The message *RXEMER* flashes in the display on line two until the emergency condition is
cleared.
11.19.2 Declaring an Emergency Call
Perform the following steps to send an emergency call to a selected system and group (or on an optionally
pre-programmed group).
1. Press and hold the red EMERGENCY button that is on top of the radio in front of the antenna for
approximately one second (this time is programmable and therefore could be longer or shorter; check
with the system administrator). The radio will transmit an emergency call request with the radio ID
until an emergency channel assignment is received.
2. When the working channel assignment is received, the radio sounds a single beep indicating the radio
has auto keyed (see Table 8-4) and is ready for voice transmission. *TXEMER* flashes on line two in
the display until the emergency is cleared.
3. Press PTT and speak into the microphone in a normal voice.
and
momentarily turn ON.
4. Release PTT when the transmission is complete.
To clear the emergency first press and hold the button. While continuing to hold the button, press the
EMERGENCY button. (This will work if the radio is programmed to clear emergencies.)
11.20
INDIVIDUAL CALLS
11.20.1 Receiving and Responding to an Individual Call
When the radio receives an individual call (a call directed only to the user's radio), it un-mutes on the
assigned working channel and displays . The first line on the display shows the logical ID number of the
unit sending the message, or the associated name if the ID number is found in the individual call list. The
radio can be programmed to ring when an individual call is received. If enabled, the ring begins five
seconds after the caller un-keys and will continue until the PTT button, the button or the individual call
mode is entered.
The volume of the ring is adjustable through the volume control levels.
134
MM-013994-001, Rev. Ap1
If a response is made by pressing the PTT to the call prior to the programmed call-back time-out, the call
will automatically be directed to the originating unit. If a response is not made before the call-back timeout, the radio will return to normal receive display, and *WHC* will appear on the first line of the LCD.
key. The radio's display will show the callers ID on
To respond after the call-back time-out, press the
the first line and WHCI=1 on the second line. Pressing the PTT button at this point will initiate an
individual call back to the original caller.
The radio stores the IDs of the last 10 callers in the Calls Received List as shown. Individual calls are
stored in the top half of the list (1-10) and Group calls are stored in the bottom half of the list (1-10). The
most recent call is stored in position 1, the second most recent call is stored in position 2, etc.
Figure 11-13: Calls Received Lists
To access the Calls Received List, press the
key twice. Use the
or
buttons to scroll through
the list. Pressing the
key will display the time elapsed since the call was received. After pressing
the display will appear similar to Figure 11-14.
Figure 11-14: WHC Individual Call Display
Pressing the PTT will initiate an individual call to the displayed logical ID. Powering the radio OFF and
ON will clear this list.
11.20.2 Sending an Individual Call
11.20.2.1 Pre-Stored Individual Calls
The following procedures describe how to initiate and complete a Pre-Stored Individual Call.
P7370 Model Radio
1. To select a pre-stored individual phone number, enter the individual call mode using the
displayed. Then scroll through the list of stored numbers using the
or
keys.
key.
is
2. Press the PTT button; when the radio is clear to transmit, turns ON, turns OFF and the channel
access tone sounds. Line one shows the called individual's name if found in the list of stored
135
MM-013994-001, Rev. Ap1
individuals or LID followed by the logical ID number of the unit being called. The message *INDV*
displays on line two.
P7350 Model Radio
1. To select a pre-stored individual number, enter the menu mode by pressing the
or
buttons.
through the mode list using the
key. Scroll
is displayed. Scroll through the list of stored phone numbers using the
2. Press
buttons until the desired number is displayed. Press
or
3. Press the PTT button; when the radio is clear to transmit turns ON, turns OFF and the channel
access tone sounds. Line one shows the called individual's name or LID. The message *INDV*
displays on line two.
11.20.2.2 Direct Dial Individual Calls (P7370 Model Only)
1. The following procedure describes how to initiate and complete a Direct Dial Individual Call.
2. The individual call ID is not stored in the pre-stored list of call IDs but the individual unit ID is
known, it can be entered directly from the keypad.
will turn OFF, and the channel access
3. Press and hold the PTT button to transmit. will turn ON,
tone will sound. Line one shows the called individual's ID followed by the logical ID number of the
unit being called. The message *INDV* displays on line two. Proceed talking into the microphone.
11.20.3 Call Storage Lists
There are two lists available for call storage in the P7300 series radios, the calls received list (1 - 10) and
the personality list (1 - 99 as defined by the user). When the individual call mode is entered by pressing
, the calls received list is available. The user can toggle to the personality list by selecting any index
other than 0 or toggle between the two lists by pressing the
key. If wrap is enabled, the calls received
list wraps on itself and not into the other list.
Figure 11-15: Calls Received and Personality Lists
The saved call list shows all ten storage locations. If no calls have been received, the saved call list will be
empty and the pre-stored list will be available upon entering the individual call mode.
136
MM-013994-001, Rev. Ap1
When in the saved call list, pressing the
key toggles the time stamp ON and OFF. The time stamp
indicates how long ago the call was received. When in the pre-stored list pressing the
key toggles the
Logical IDentification (LID) ON and OFF.
11.21
TELEPHONE INTERCONNECT CALLS
11.21.1 Receiving a Telephone Interconnect Call
When the radio receives a telephone interconnect call (a call directed only to the user's radio), it un-mutes
on the assigned working channel and displays . The first line displays *PHONE*. The second line
displays *INDV*. Proceed with the call. Press the PTT to talk, release the PTT to listen.
11.21.2 Sending a Telephone Interconnect Call
11.21.2.1 Pre-Stored Number
Use the following procedures to initiate and complete a Telephone Interconnect call.
key. Use the
or
key. Use the
P7350 Model: To select a previously stored phone number, press the
buttons to select the menu option PHN CALL. Press the
key again then use the
buttons to scroll through the list of pre-stored numbers.
or
or
1. P7370 Model: To select a previously stored phone number, press the
buttons to scroll through the list of stored numbers.
2. Press and release the PTT button. When the radio is clear to transmit, turns ON, turns OFF and
the channel access tone sounds. Line one shows the accompanying name selected from the list of
stored numbers. The message *PHONE* appears on line two of the display. The radio then
automatically transmits the programmed number stored in the special call queue.
3. A telephone ring will be heard from the speaker. When someone answers the phone, press the PTT
button and speak into the microphone. Release the PTT button to listen to the callee. Unsuccessful
interconnect signaling returns the radio to the normal receive mode and the number remains displayed
until the special call is cleared or the time-out expires or another group or system is selected.
Terminate a call by pressing the button.
In half-duplex mode, only one person may talk at a time. The radio PTT button needs
to be pressed in order to communicate to the individual called and released for the
individual called to be heard.
11.21.2.2
Direct Dialing of Phone Calls (P7370 Model Only)
1. If the phone number is not stored in the pre-stored list of phone numbers, but the phone number is
key, then enter the
known, it can be entered directly from the keypad. Start by pressing the
required number from the keypad. Press and release the PTT button.
The last number directly entered can be recalled by first pressing
PTT button.
then pressing the
2. A telephone ring can be heard from the speaker. When someone answers the phone, press and hold
the PTT button and speak into the microphone. Release the PTT button to listen to the individual
137
MM-013994-001, Rev. Ap1
called. Unsuccessful interconnect signaling returns the radio to the normal receive mode and the
number remains displayed until the special call is cleared or the time-out expires or another group or
system is selected.
3. To terminate the call, momentarily press the
button.
11.21.3 Dual-Tone Multi-Frequency: Overdial/Conventional Mode
Once the radio has established a connection to the public telephone system, it may be necessary to “overdial” more digits to access banking services, answering machines, credit card calls, or other types of
systems that require Dual-Tone Multi-Frequency (DTMF) access digits.
Overdial operation can also be used to initiate a telephone interconnect call via DTMF signaling if a dial
tone has already been accessed on the system. This method makes a telephone interconnect call while
operating in the conventional mode but will also function in trunked mode if a dial tone is directly
accessible.
Telephone numbers and other number sequences for overdialing can be stored in the phone list when
key, then following the selection
programming the radio. These numbers are accessed by pressing the
mode rules. Perform the following procedures to access and dial these stored numbers.
P7350 Model Radio
1. Follow the procedure in Section 11.21.3 to establish a connection to the telephone system or consult
the system administrator for the procedure to access a dial tone on the trunked or conventional
system.
2. Enter selection mode first to enable entry of Overdial numbers by pressing the
button.
or
3. Follow the selection mode rules to call up a stored number from the phone list: Use the
buttons to scroll through the list of stored numbers. is displayed. Press the PTT to send the overdial
sequence once. If the number needs to be transmitted again it must be selected or entered again (this
prevents unwanted numbers from being sent the next time the PTT button is pressed during the call).
Overdial select/entry mode remains active until the call is dropped, cleared, or
overdial select/entry mode can be re-entered if the call is still active by pressing
is pressed. The
P7370 Model Radio
1. Follow the procedure in Section 8.23.2 to establish a connection to the telephone system or consult
the system administrator for the procedure to access a dial tone on the trunked or conventional
system.
2. Overdial numbers are transmitted using one of the following methods:
METHOD 1:
138
button.
1. Enter the overdial selection mode by pressing the
2. Use the
or
buttons to scroll through the list of stored numbers.
is
displayed. Press the PTT to send the overdial sequence once. If the number needs
to be transmitted again it must be selected or entered again (this prevents unwanted
numbers from being sent the next time the PTT button is pressed during the call).
Overdial select/entry mode remains active until the call is dropped, cleared, or
is pressed. The overdial select/entry mode can be re-entered if the call is still active
by pressing
MM-013994-001, Rev. Ap1
METHOD 2:
(P7370 model radios only)
button.
1. Enter the overdial selection mode by pressing the
2. Press and hold the PTT button while entering the overdial number sequence from
the keypad. This method sends DTMF tones during individual, telephone
interconnect, trunked group, or conventional channel calls. Press the PTT to send
the overdial sequence once. If the number needs to be transmitted again it must be
selected or entered again (this prevents unwanted numbers from being sent the next
time the PTT button is pressed during the call). Note: Anytime the PTT button is
pressed and held, the keypad is enabled for DTMF entry.
Overdial select/entry mode remains active until the call is dropped, cleared, or
is pressed. The overdial select/entry mode can be re-entered if the call is still active
by pressing
This overdial select/entry mode remains active until dropped, cleared, or
select/entry mode can be re-entered if the call is still active by pressing the
11.22
is pressed. The overdial
button.
PROGRAMMABLE ENTRIES
11.22.1 Pre-Storing Individual and Telephone Interconnect Calls from the
Keypad
Individual Call ID numbers, telephone numbers, and other number sequences for overdialing are stored in
the special calls lists when programming the radio. The first ten entry locations of these lists can be
changed by the radio operator. The keypad is used when adding, changing, and storing numbers in these
entry locations.
Use the following procedure to store a number in one of the first ten entries of a special call list:
1. Press the
or
button to enter the individual call list or the phone call list.
2. Scroll through the list using the
or
ENTRY is displayed if the location is empty.
is displayed.
keys until one of the first ten entries is reached. NO
, or
3. Enter the desired number. If necessary, a pause can be entered by pressing and holding 0-9,
until an underscore appears in the display (telephone interconnect only). The individual call list
entries will accept up to 5 digits. The phone call list entries accept a combination of up to 31 digits
and pauses.
4. Press and hold the
key until the display changes indicating that the number has been stored.
Repeat steps 1-4 to store additional numbers, to change numbers already stored, or to change the storage
location of a number.
11.23
STATUS/MESSAGE OPERATION
The Status and Message operations allow for the transmission of a pre-programmed status or a preprogrammed message to an EDACS site. Each Status and Message is assigned an ID then crossreferenced with the representative status condition (“Off Duty,” for example) or a message (“Call home”).
In addition, Status conditions can also be associated with a programmable Menu entry (required for
second method of transmitting a Status condition (see Section 8.25.1).
139
MM-013994-001, Rev. Ap1
11.23.1 Status Operation
P7370 Model Radio
One of two methods can be used to transmit a status condition.
METHOD 1:
key, then use the
or
buttons to scroll to the pre-programmed
1. Press the
status condition. STATUS and 0 through 9 pre-programmed status selections are
available from the menu.
2. If STATUS is selected, you need to enter the number of the status condition you
intend to transmit. If no status has been programmed for the selected number key,
the radio will display NO ENTRY. A valid selection will display the status for a preprogrammed time.
key has been pressed (the
key will override the
After the time-out expires or the
time-out period), the status is selected and will be transmitted to the site or stored in the
radio memory where it can be polled by the site at a future time.
METHOD 2:
1. Press the
key.
2. Press the corresponding pre-programmed 0 through 9 status condition key. If no
status has been programmed for the selected number key, the radio will display
NO ENTRY. A valid selection will permit the status condition to appear in the top
line of the display and the status ID to appear in the second line of the display for a
pre-programmed time.
key has been pressed (the
key will override the
After the time-out expires or the
time-out period), the status is selected and will be transmitted to the site or stored in the
radio memory where it can be polled by the site at a future time.
View the currently selected status after it has been transmitted by pressing the
key and then the
key and then the button prior to the time-out period. If the status was not sent successfully to the site,
the text associated with the status condition will flash in the display.
The status selection can be changed by pressing a different status key 0 through 9, or the status operation
can be cancelled by pressing Option Button 2 . Both operations must be carried out prior to the timeout period.
11.23.2 Message Operation
The following method can be used to transmit a message using the Message Operation.
1. Press the
key.
2. Press the corresponding 0 through 9 pre-programmed “message” key. If no message has been
programmed for the selected number key, the radio will display NO ENTRY. A valid selection will
permit the message to appear in the top line of the display and the message ID to appear in the second
line of the display for a pre-programmed time.
The message selection can be changed by pressing a different message key 0 through 9, or the message
operation can be cancelled by pressing Option Button 2 . Both operations must be carried out prior to
the pre-programmed time-out period.
11.24
MACRO KEY OPERATION
Macro key operation permits the user to accomplish a series of keystrokes with a single "macro"
keystroke. Each Macro Key is capable of executing up to twenty (20) keystrokes, to any push button input
140
MM-013994-001, Rev. Ap1
(i.e., keypad keys, OPTION buttons, etc.). Each macro key can be pre-programmed to activate when
pressed or when released.
A macro key may also be pre-programmed to change the key stroke sequence the next time the macro key
is activated.
For detailed operation and assignment of macro keys, contact your communications supervisor or
administrator.
11.25
PORTABLE DATA
The P7300 series portable radios, when operating in the EDACS Trunked configuration, permit both
voice and data calls to be transmitted and received. The radio can handle only one type of call at a time;
however, either data or voice is selected transparently by the operator through normal usage of the radio.
Data communications is not supported in conventional mode.
The radios can be connected to a Mobile Data Terminal (MDT) or to a host computer. Any RS-232
compatible device that supports the Radio Data Interface (RDI) protocol (Version 1.91 or greater) may be
connected to the radio. Support for MDTs or host computers is a programmable option per radio.
Additionally, radios may also be programmed for data only operation (no voice calls transmitted or
received).
11.25.1 Displays
The following will be displayed during the various states of data mode of operation:
TX DATA
Appears on top line of display when the radio is transmitting a data call.
RX DATA
Appears on top line of display when the radio is receiving a data call.
DATA OFF
Appears on top line of display when the radio is in the data disabled state.
DATA ON
Appears for two seconds on top line of display when the radio is toggled to the data
enabled state.
11.25.2 DATA OFF Operation
The radio can be placed in the data disabled state by any of the following methods. When the data state is
disabled, DATA OFF appears on the top line of the display.
•
Declaring an emergency (not to be used unless an actual emergency condition exists). Alert tone will
sound.
•
Pressing Option Button 1
•
Pressing the pre-programmed “no data” (ND) key. Refer to previous bullet.
(if pre-programmed as “no data” key). Alert tone will sound.
11.25.3 DATA ON Operation
The data state is enabled by one of the following (depending on how it was disabled). DATA ON will
appear on the top line in the display for two seconds then the display will return to normal.
•
Pressing the pre-programmed “no data” (ND) key toggles data state ON or OFF.
•
Clearing an emergency. This is valid only if the emergency caused “DATA OFF” operation.
141
MM-013994-001, Rev. Ap1
11.25.4 Exiting Data Calls
Under normal conditions, the radio enters the scan lockout mode and returns to the control channel after
completion of a data call (transmit or receive). If, during a data call, one of the following operations
occurs, the data call is immediately terminated and the radio performs the desired function:
•
If the PTT is activated.
•
If an Emergency is declared by pressing the pre-programmed emergency button.
•
If a group or system is changed.
11.25.5 Scan Lockout Mode
Following the transmission or reception of a data call, if scan is enabled, scanning will stop temporarily.
There are two independent pre-programmed times associated with this mode; one after a received data
call and one after a transmitted data call. During this time the scan indicator will flash to indicate that scan
is enabled but temporarily suspended. This condition typically returns to normal scan operation when the
pre-programmed time expires; however, the following operations and conditions will terminate the scan
lockout mode before the timeout has expired.
•
Press the
•
Press the PTT.
•
Change a group or system.
•
Enter Telephone Interconnect mode.
•
Enter Individual call mode.
•
Receive a new emergency assignment.
•
Declare or clear an emergency.
•
Receive an individual or phone call.
•
Receive an Agency, Fleet, or System All Call.
•
Press
button.
(P7350 model) or
(P7370 model) to toggle Scan ON or OFF.
11.25.6 Data Lockout Mode
During the voice call scan hang time (pre-programmed) the radio will not receive data calls.
11.26
GROUP CALLS IN P25 MODE
11.26.1 Transmitting a Group Call
1. Select the desired P25 system. (P25 icon will appear in display.)
2. Select the Talk Group/Conventional Channel. (Selected simultaneously using either the
System/Group/Channel control knob or the group key.)
3. Press and hold the PTT.
4. When a grant tone is received (if enabled through programming) speak into the microphone.
5. Release PTT and wait for response.
142
MM-013994-001, Rev. Ap1
11.26.2 Receiving a Group Call
1. The radio will unmute according to the squelch mode defined in the radio personality (monitor,
normal, selective).
2. Select the desired P25 system and Talk Group/Channel or turn scan on and make sure the desired
channel is in the scan list.
3. When the radio receives a P25 call, the radio will unmute and the channel name will appear in the
display.
4. Press the PTT button to respond.
11.27
INDIVIDUAL CALLS IN P25 MODE
11.27.1 Transmitting an Individual Call
1. Select the desired P25 system. (The P25 icon will appear in the display.)
2. Select the radio unit to call (callee source ID) from the pre-programmed individual call list or enter
the ID number on the radio keypad.
3. Press and hold the PTT.
4. When grant tone is received (if enabled through programming) speak into the microphone.
5. Release the PTT.
11.27.2 Receiving an Individual Call
1. The radio will unmute according to the squelch mode defined in the radio personality (monitor,
normal, selective).
2. Select the desired P25 system and Talk Group/Channel or turn scan on and make sure the desired
channel is in the scan list.
3. When the radio receives a P25 call, the radio will unmute and the ID of the transmitting radio will
appear in the display.
4. Press the PTT button to respond.
5. Unanswered calls will appear in the Who Has Called (WHC) list.
11.28
EMERGENCY GROUP CALLS IN P25 MODE
There is no method available for a system-wide Emergency clear. An emergency group call
must be cleared on each individual radio.
11.28.1 Declaring an Emergency Group Call
1. Select the desired P25 system and Talk Group/Channel.
2. Press the red emergency button on the top of the radio. The radio will broadcast a short emergency
transmission with the emergency bit set. “TXEMER” will appear in the display of the transmitting
radio.
143
MM-013994-001, Rev. Ap1
3. While the PTT is NOT pressed, the mic will be open and the radio will broadcast an approximately 2
second transmission (e.g., background noise) which will be repeated at 10-30 second intervals.
4. Press the PTT to stop the short transmissions.
5. To send a voice message, press the PTT and speak into the microphone.
6. To clear an emergency from the transmitting radio, perform one of the following steps:
•
Change systems.
•
Change channels (if not prohibited by programming).
•
Cycle power by turning radio off and then back on.
•
Press the Clear and Emergency buttons simultaneously, providing the Clear Emergency option is
enabled in the Supervisory Options in the personality.
11.28.2 Receiving an Emergency Group Call
1. Select the desired P25 System and Talk Group/Channel.
2. When the radio detects an incoming Emergency Group Call, the radio will sound an alert tone and
“RXEMER” will appear in the display.
3. Voice or emergency transmissions will be heard at the receiving radio.
4. To clear an emergency from the receiving radio, perform one of the following steps:
144
•
Change systems.
•
Change channels (if not prohibited by programming).
•
Cycle power by turning radio off and then back on.
•
Press the Clear and Emergency buttons simultaneously, providing the Clear Emergency option is
enabled in the Supervisory Options in the personality.
MM-013994-001, Rev. Ap1
This page intentionally left blank
145
MM-013994-001, Rev. Ap1
TECHNICAL ASSISTANCE
AND
WARRANTY INFORMATION
146
MM-013994-001, Rev. Ap1
12 IMMERSIBLE P7300 PREVENTIVE MAINTENANCE
Those P7300 radios labelled “immersible” (see Figure 12-1) require periodic testing using specialized
equipment to verify the radio’s watertight integrity.
Preventive Maintenance for Immersion-Rated Radios
CAUTION
P7300 multi-mode series portable radios with Immersion Option MAEV-MR must
be serviced by a service center authorized and certified by Harris to perform the
necessary tests to verify watertight integrity. As part of a thorough preventive
maintenance plan, Harris recommends Immersion-Rated P7300 multi-mode series
portable radios be, at a minimum, tested and re-certified on an annual basis. Harris
further recommends that the radios be tested on or close to the anniversary of the
ship date printed on the Model Number label on the back of the radio (see Figure
12-1).
Figure 12-1: Labels
12.1 TECHNICAL ASSISTANCE – IMMERSIBLE P7300
To preserve the watertight integrity of the P7300 portable radio, the radio must be serviced by a service
center authorized and certified by Harris to perform the necessary tests to verify the watertight integrity.
147
MM-013994-001, Rev. Ap1
Use one of the following methods to locate the nearest service center authorized to service the radios
warranted under Option MAEV-MR.
•
Contact Harris Technical Assistance Center (TAC) at 1-800-528-7711 (in the U.S. and Canada)
or at 1-434-385-2400 (worldwide) for a listing of service centers authorized by Harris to service
P7300 radios with Option MAEV-MR.
•
If a TECH-LINK subscriber, access Harris TECH-LINK web site for a list of Customer Service
Managers (CSM) or Regional Service Managers (RSM) that will provide a list of the nearest
service shops authorized by Harris to service P7300 radios with Option MAEV-MR.
or
148
MM-013994-001, Rev. Ap1
13 TECHNICAL ASSISTANCE
The Technical Assistance Center's (TAC) resources are available to help with overall system operation,
maintenance, upgrades and product support. TAC is the point of contact when answers are needed to
technical questions.
Product specialists, with detailed knowledge of product operation, maintenance and repair provide
technical support via a toll-free (in North America) telephone number. Support is also available through
mail, fax and e-mail.
For more information about technical assistance services, contact your sales representative, or call the
Technical Assistance Center at:
North America:
1-800-528-7711
International:
1-434-385-2400
Fax:
1-434-455-6712
E-mail:
tac@tycoelectronics.com
149
MM-013994-001, Rev. Ap1
14 BASIC TROUBLESHOOTING
Use Table 14-1 as a troubleshooting guide if the radio is not functioning properly. If additional assistance
is required, contact a qualified service technician or call Harris at 1-800-528-7711.
Table 14-1: Troubleshooting
SYMPTOM
150
POSSIBLE CAUSE
POSSIBLE SOLUTION
Radio will not turn
on.
Low battery charge.
Change the battery pack to a fully charged pack.
No Audio.
Speaker volume is muted.
Increase the volume level.
Poor Audio.
User is in a poor coverage Move to a better coverage area.
area or not on the
network.
Radio powers off for
no apparent reason.
Radio
may
experiencing very
voltage.
Radio will not
transmit.
Radio may be out of Return to coverage area if possible. If overheated,
coverage area or may be let radio cool before retrying transmission. Report
overheated.
this failure to an authorized technician.
be Have the battery checked by an authorized
low technician.
MM-013994-001, Rev. Ap1
151
MM-013994-001, Rev. Ap1
152
RF Communications Division | 221 Jefferson Ridge Pkwy. | Lynchburg, VA USA 24501
Tel: 1-800-528-7711 (Outside USA, 1-434-35-2400) www.rfcomm.harris.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Kathy
Create Date                     : 2009:06:17 16:47:00-07:00
Modify Date                     : 2009:06:17 16:47:17-07:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2009:06:17 16:47:17-07:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - 2009141 MA-COM P7300 700_800 MHz FCC Test Report R1.0.doc
Creator                         : Kathy
Document ID                     : uuid:c2ef5d55-f8f7-44e9-bff7-86989fd9bceb
Instance ID                     : uuid:aa45a986-29fa-4d9b-8759-b1b2c8adc149
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Page Count                      : 155
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OWDTR-0054-E

Navigation menu