HEI Advanced Medical Division L100 Link-IT Wireless Connectivity Device User Manual 01090 00059A
HEI, Inc. Advanced Medical Division Link-IT Wireless Connectivity Device 01090 00059A
Users Manual
Link-iT™ System USER’S MANUAL Revision A 12/10/2003 Part Number 01090-00059 For Orders and Support: 1-800-866-3716 www.heii.com This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. TABLE OF CONTENTS Overview ................................................................................................... 3 Safety Instructions.................................................................................... 3 2.1 Symbols ............................................................................................ 3 2.2 Precautions........................................................................................ 3 2.3 Product Labeling & Identification .................................................... 5 System Description ................................................................................... 6 3.1 Product Configurations And Descriptions ........................................ 7 3.2 Features Of The Link-iT Module...................................................... 8 3.2.1 Communication Ports................................................................... 8 3.2.2 Link-iT™ Module LED Indicators............................................... 9 Installation .............................................................................................. 10 4.1 Connecting With RS-232................................................................ 10 4.2 Connecting With USB .................................................................... 10 4.3 Connecting With A Wired Network ............................................... 11 4.4 Connecting With A Wireless Network ........................................... 11 4.5 Connecting With IrDA.................................................................... 11 4.6 Connecting To Power ..................................................................... 12 4.7 Use Of Link-iT Mounting Bracket.................................................. 14 Maintenance and Support ..................................................................... 15 5.1 Initial System Configuration........................................................... 15 5.2 Software Updates............................................................................ 15 5.3 Cleaning.......................................................................................... 15 5.4 Troubleshooting .............................................................................. 16 Specifications .......................................................................................... 17 Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 2 of 20 1 OVERVIEW This User’s Manual provides guidance on use and routine maintenance of the Link-iT™ System. End-Users should read and understand this manual completely before using any components of the Link-iT™ System. This manual does not cover configuration, installation of software, repair, or use of the LinkiT™ modules in a system application. For installation and compatibility issues, please contact your site administrator. Audience: The primary audience for the Link-iT™ System User’s Manual is the clinical care provider. A secondary audience includes technical service and management personnel. SAFETY INSTRUCTIONS 2.1 SYMBOLS Caution, refer to the User’s Manual Caution, Dangerous voltage 2.2 PRECAUTIONS If any electrical component is suspect of or found to be defective or inoperable, discontinue use of the Link-iT™ System. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 3 of 20 equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the Link-iT™ System components. • Increase the separation between the equipment and LinkiT™ System components. • Connect the equipment into an outlet on a circuit different from that to which the Link-iT™ System is connected. • Consult the dealer or an experienced technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 4 of 20 2.3 PRODUCT LABELING & IDENTIFICATION Product Model Device and Agency Labels L100 L100-W L100-W-B Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 5 of 20 T100 SYSTEM DESCRIPTION The Link-iT™ System is a compact intelligent system intended to bring processing power and interface capability to a variety of needs in the medical device arena, particularly in the area of connecting medical devices and information systems. The system includes Link-iT™ modules and power supplies. The modules connect to standard interfaces, including RS-232, IrDA, USB, Ethernet (10BaseT and 100BaseT), and 802.11b (WiFi) wireless networking. The Link-iT™ power supply provides direct power and battery charging capability. The following items are external components supported by the Link-iT™ System: • Medical devices and their specific serial protocols • Information systems and their specific interface requirements (e.g. XML or HL7) Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 6 of 20 Specific aspects of the interface are dictated by the external device and may require customization. Before connecting to any device, consult the operator/user’s manual provided by the device manufacturer. Contact your site administrator with questions regarding your system environment. 3.1 PRODUCT CONFIGURATIONS AND DESCRIPTIONS Product Configuration L100 T100 L100-T L100-W-T Description Link-iT™ module Link-iT™ power supply* Link-iT™ module and Link-iT™ power supply Link-iT™ module with WiFi and Link-iT™ power supply Link-iT™ module with WiFi, built-in battery pack and Link-iT™ power supply L100-W-B-T *Includes 1 standard RJ-45 cable (6 ft) Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 7 of 20 3.2 FEATURES OF THE LINK-IT MODULE 3.2.1 Communication Ports Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 8 of 20 Interfaces supported by the Link-iT™ module include two DB-9 connectors standard for serial interfaces, USB that conforms to the USB 2.0 specification, an IrDA port for infrared communication, and a RJ-45 connector standard for a wired network interface. The RJ-45 connector also supplies DC power to the Link-iT™ module. A single RJ-45 cable is supplied with the Link-iT™ power supply. 3.2.2 Link-iT™ Module LED Indicators LEDs on the Link-iT™ module indicate function or activity for specific aspects of the system. Power LED - illuminates when the Link-iT™ module has DC power supplied or flashes/blinks when the Link-iT™ module has battery power supplied. WiFi LED – illuminates when the Link-iT™ module has active wireless communication. Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 9 of 20 Network LED – illuminates when the Link-iT™ module has active network communication. Serial LED – illuminates when there is active serial communication or USB communication between the Link-iT™ module and an external device/component. IrDA LED – illuminates when there is active infrared communication between the Link-iT™ module and an external system. INSTALLATION The Link-iT™ module is configurable with various interfaces based on the product model type. NOTE: Interface connections should be made prior to powering on the Link-iT™ module. 4.1 CONNECTING WITH RS-232 To interface via RS-232, use a serial cable to connect either DB-9 Serial Communication port of the Link-iT™ module to the serial connector on the external device (e.g. medical instrumentation). When the Link-iT™ module is powered and has active serial communication, the Serial LED will illuminate. Custom cabling may be required for external device connectivity, consult your site administrator. 4.2 CONNECTING WITH USB A USB port is available to support additional device interfaces or to support enhanced system capability. To interface via USB, connect the USB Communication port of the Link-iT™ module to Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 10 of 20 the external device (e.g. external hard drive, printer). When the Link-iT™ module is powered and has active USB communication, the Serial LED will illuminate. 4.3 CONNECTING WITH A WIRED NETWORK A typical interface via Ethernet will use a standard RJ-45 cable to connect the Ethernet and Power Connection of the Link-iT™ module to the “To Link-iT™” port of the Link-iT™ power supply (T100). A second RJ-45 cable should connect the “To Network” port of the Link-iT™ power supply (T100) to the hospital network jack or hub. The Network LED on the Link-iT™ module will illuminate when powered and there is active network communication. 4.4 CONNECTING WITH A WIRELESS NETWORK Wireless communication is available for Link-iT™ modules with “W” in the model number. When a Link-iT™ module configured for 802.11B connectivity has active wireless communication, the WiFi LED will illuminate. At this time, simultaneous operation of Ethernet and 802.11B on a single Link-iT™ module is not supported. 4.5 CONNECTING WITH IRDA An IrDA (infrared) interface is provided with the Link-iT™ module for integration with a PDA or similar systems. The IrDA LED will illuminate when there is infrared communication between a Link-iT™ module and an external infrared system. Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 11 of 20 4.6 CONNECTING TO POWER Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 12 of 20 To power a Link-iT™ module and/or charge a battery pack: 1) Connect the Ethernet and Power Connection of the LinkiT™ module to the “To Link-iT™” port of the Link-iT™ power supply (T100) using a standard RJ-45 cable. 2) Plug the T100 directly into a power outlet. 3) Check to see that the Power LED on the Link-iT™ module illuminates indicating DC Power is applied. If the Link-iT™ module has a battery pack that is charged, the main power supply may be disconnected and the Link-iT™ module used in an ambulatory function for up to 4 hours. The Power LED on the Link-iT™ module will flash as an indication of battery power. The absence of an illuminated Power LED indicates there is no power to the Link-iT™ module. Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 13 of 20 4.7 USE OF LINK-IT MOUNTING BRACKET The Link-iT™ module can be mounted to various surfaces using a Link-iT™ mounting bracket. Slide the Link-iT™ module onto the guides of the bracket. Note: Brackets are available in various configurations for LinkiT™ modules, both with battery pack and without battery pack. Contact your site administrator before attaching mounting brackets to fixtures or equipment. Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 14 of 20 5 MAINTENANCE AND SUPPORT 5.1 INITIAL SYSTEM CONFIGURATION The Link-iT™ System should be configured only by trained technical personnel. Contact your site administrator if this is necessary. 5.2 SOFTWARE UPDATES Software for the Link-iT™ module should be updated only by trained technical personnel. Contact your site administrator if this is necessary. 5.3 CLEANING CAUTION: Disconnect and unplug the Link-iT™ System components prior to cleaning. CAUTION: Do not immerse the Link-iT™ System components in water or other fluids. CAUTION: Do not use harsh chemicals or apply cleaning agents directly on the Link-iT™ System components. The Link-iT™ System components should be cleaned by using a cloth dampened with rubbing alcohol or all purpose cleaner and wiping the exterior surfaces. Be careful not to saturate the LinkiT™ System components, as excessive liquid will damage the electronics. Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 15 of 20 5.4 TROUBLESHOOTING Symptom Problem No Power LED No power to Link-iT™ module No Serial LED No serial communication No USB Communication No WiFi LED No wireless communication No Network LED No Network communication No IrDA LED No infrared communication Link-iT™ System USER’S MANUAL 01090-00059, Revision A Action Check RJ-45 cable connection. Check T100 is plugged in. Check for charged batteries. Contact site administrator. Check serial cable connection. Check USB connection. Contact site administrator. Check model of Link-iT™ module to verify wireless capability. Contact site administrator. Check RJ-45 cable connections. Contact site administrator. Contact site administrator. Page 16 of 20 6 SPECIFICATIONS Dimensions Link-iT™ module without battery pack: Width 60 mm (max) Depth 105 mm (max) Height 29 mm (max) Link-iT™ module with battery pack: Width 60 mm (max) Depth 105 mm (max) Height 47.5 mm (max) Wall Transformer (T100): Width 60 mm (max) Depth 105 mm (max) Height 30 mm (max) Operational Temperature: Humidity: Storage Conditions Temperature: Humidity: Link-iT™ System USER’S MANUAL 01090-00059, Revision A +0°C to +40°C 5% to 95% relative humidity non-condensing -20°C to +45°C 5% to 95% relative humidity non-condensing Page 17 of 20 NOTES: Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 18 of 20 NOTES: Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 19 of 20 Link-iT™ System USER’S MANUAL 01090-00059, Revision A Page 20 of 20
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 20 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:7e6113fd-e79a-42bb-8cab-2820222fca84 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2003:12:19 17:41:37-07:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2003:12:19 17:41:37-07:00 Document ID : uuid:dffcda16-76ad-46dc-a323-0993e65a1f05 Format : application/pdf Title : Microsoft Word - 01090-00059A.doc Creator : KJH Author : KJHEXIF Metadata provided by EXIF.tools