AMR100 Property Pass Reader Installation Manual

Download: HID Global 6015 User Manual I Master       5       5 900       5 90
Mirror Download [FCC.gov]HID Global 6015 User Manual I Master       5       5 900       5 90
Document ID27720
Application IDEIoWRfEj5AOINBJ6v0AuLw==
Document DescriptionAMR100 Property Pass Reader Installation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.69kB (371158 bits)
Date Submitted1999-03-16 00:00:00
Date Available1999-04-30 00:00:00
Creation Date2017-12-28 03:05:09
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-28 03:05:09
Document TitleI:Master†5†5-900†5-90
Document CreatorI:Master†5†5
Document Author: Unknown

AMR100 Property Pass Reader Installation Manual (6015-900)
Installation Requirements
Parts List (Included)
The following instructions will explain the installation and
operation procedure for the AMR100 Property Pass
Reader. The instructions include these sections:
1) AMR100 Property Pass Reader
2) O-ring - 12"diameter x .25" thick
3) #6-32x.625 Flathead Screw
4) Installation Manual
5) Front Cover Label
6) Strain Relief Nut
Parts List (NOT Included)
1) External 12V power supply
2) #6 Mounting Screws
3) Cable (See requirements below)
A/R
A/R
Installation Instructions
Mounting Preparation
Cabling Preparation
Mounting
O-Ring
Switch Settings
Jumper Settings
Power Supply
Cover Installation
Quantity
Cabling Requirements
Shielded
Power & Ground - 18AWG- 22AWG
All other signals - 24 AWG minimum
Strain Relief Nut cable range: .19 to .390
AMR100 Property Pass Reader
11.80
1.00
.156 X .04 DEEP
12 PLACES
Place screw to
secure top cover
here.
4.00
2.625
HID ProxTrak
TM
1.64
L ISTED
ACCESS CONTROL SYSTEM UNIT ACCESSORY.
REFER TO OPERATORS MANUAL 6 0 1 5 -9 0 0 .
EL ECTRICAL RATING: 1 0 .8 -1 3 .2 VDC/2 5 0 mA
8 T2 9
HID CORPORATION
FCC ID: JQ66015
Th i s d e v i c e c o mp l i e s wi th p a rt 1 5 o f th e FCC
ru l e s . Op e ra ti o n i s s u b j e c t to th e fo l l o wi n g two
c o n d i ti o n s : (1 ) Th i s d e v i c e ma y n o t c a u s e h a rmfu l
i n te rfe re n c e , a n d (2 ) Th i s d e v i c e mu s t a c c e p t a n y
i n te rfe re n c e re c i e v e d , i n c l u d i n g i n te rfe re n c e th a t
1 9C9 8 HID CORPORATION
ma y c a u s e u n d e s i re d o p e ra ti o n .
U.S. PATENT NO. 4 ,7 3 0 ,1 8 8 5 ,0 4 1 ,6 2 5
11.80
0.00
1.64
2.625
4.00
Figure 1
4.00
4.00
Installation Instructions
Mounting Preparation
1. Determine an appropriate mounting position for the
AMR100 Reader.
2. Install an electrical box or drill mounting holes for #6
fasteners. Starter holes for mounting are indicated on
Figure 2.
3. The Reader should be mounted at least 6" away from
any metallic surface 12"x12" or larger. Incidental metal
such as aluminum studs and conduit can be compensated.
Important Product Specifications
Environmental Characteristics
Operating Temperature Range
Storage Temperature Range
-0oC to 70o C (32 o F to 150o F)
-40oC to 85o C (-40o F to 185o F)
Power Requirements
Operating Voltage Range
Peak Current 12VDC
Average Current
Excitation Frequency
12.0VDC ± 1.2VDC
1.5A
1.0A
125KHz ± 1 KHz
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A
1 of 6
Figure 2
Cable Preparation
1. Route the cable from the AMR100
Reader and/or power supply to the
Host.
2. Prepare the cable by cutting the jacket
back 2" and strip the wires 1/4".
Tinning the wires is not required.
3. Install the cable strain relief nut #1 on
the rear of the AMR100 Reader as
indicated in Figure 2 . (Strain relief nut
#2 is for use with the LCD display unit
that is purchased separately. If no
LCD unit is being used and a water
tight seal is necessary, place a cable
segment into the strain relief nut #2
and tighten it)
4. Connect the Reader to the Host
according to the terminal description in
Figure 4. Do not leave extra loops of
wire inside the Reader housing.
5. Tighten the strain relief nut to secure
the cable.
6. Connect the drain line of the shield to
TB5-2. (See Figure 3 ) If it is bare,
sleeve it to avoid short circuits to the
other wires.
7. The opposite end of the drain line
should be connected to the negative
terminal and the frame connections of
the power supply.
8. Connect the power supply ground to
TB5-3. (See Figure 3 )
8.00
12 PLCS, .156
STARTER HOLES
FOR WALL MOUNT
5.25
TB2-1 TD
TB2-2 RD
TB2-3 SIGNAL RTN
TB2-4 485+
TB2-5 485TB2 TB2-6 SIGNAL RTN
TB2-7 RELAY1 N/C
TB2-8 RELAY2 N/O
TB2-9 RELAY1 COMM
TB2-10 RELAY2 N/C
TB2-11 RELAY2 N/O
TB2-12 RELAY2 COMM
TB4-1 D0
TB4-2 D1
TB4-3 D2
TB4-4 D3
TB4 TB4-5 D4
TB4-6 D5
TB4-7 D6
TB4-8 D7
TB4-9 +V
TB4-10 RTN3
TB5-1 +DC
TB5 TB5-2 SHIELD
TB5-3 GROUND
TB3-1 RTN1
TB3-2 +5V
TB3-3 INT
TB3-4 RS
TB3 TB3-5 R/W
TB3-6 EN
TB3-7 GREEN OUT
TB3-8 RED OUT
TB3-9 BEEP OUT
TB3-10 RTN2
TB1-1 DATA 0
TB1-2 DATA 1
TB1-3 CARD PRESENT
TB1-4 DATA RTN
TB1 TB1-5 GREEN IN
TB1-6 RED IN
TB1-7 BEEP IN
TB1-8 HOLD
TB1-9 TAMPER
TB1-10 COMMON
3.28
TB3
TB1
TB5
E5
E4
SW2
SW3
SW6
SW4
11
P17
P6 P9
P10 P11
8.00
P12
P2
1 P5 1 P8
P14
P24
1 P3
P16
COVER
P4
P1
P18
P15
P20
P7
P13
111
P19
SW1
1 1
R5
TB2
SW5
TB4
SCREW
O-RING
BASE
CABLE STRAIN RELIEF NUT
Figure 4
Figure 3
TB3
TB4
TB1
TB5
TB2
This label is located on the inside
base of the AMR100 Reader. It
shows all the terminal connections
for interfacing the AMR100 Property
Pass Reader with the Host. TB3 and
TB4 are for use with the LCD add-on
unit.
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A
2 of 6
Mounting
1. Mount the base of the AMR100 Property Pass Reader
to the prepared surface using the starter holes indicated
in Figure 2.
2. These holes are not through holes and require drilling
before mounting.
3. Choose the holes to be used and drill with a 5/32 (.156)
inch bit. Use #6 screws only.
SWITCH #1
Report Settings
ON
OFF
Set Tamper Latch Mode
*Tag command is "Set
Tamper"
Tag command is read
from EEPROM
Re-report ID's
*Tag ID's are rereported on each Poll
Reports only ID's that
are different from
previous
Indicator re-report
*Indicators activate for
every ID
Indicators activate only
for different from
previous
Fast indicator duration's
Use 4Xfaster indicator
durations
*1X durations
Acquisition test reports
Sends receiver and
power level test reports effects Simplex output
and LCD
O-Ring
1. After the AMR100 Reader base is mounted, install the
rubber o-ring by stretching around the reader base and
placing it in the groove located along the edge. See
Figure 2 for details.
Switch Settings
Set the DIP Switches labeled Switch 1 - Switch 4
(Figure 5) according to the following tables.
EPP Database
Switch #1 - Report Settings
Switch #2 - Serial Settings
Switch #3 - Hardware Settings
Switch #4 - Initialization Settings
* Denotes the default setting.
LCD Reports
LCD reports ID and
sensor messages
*Host only control of
LCD
Test LCD
Test
*LCD. For factory use
only
8.00
12 PLCS, .156
STARTER HOLES
FOR WALL MOUNT
5.25
TB3
TB5-1 +DC
TB5 TB5-2 SHIELD
TB5-3 GROUND
TB4-1 D0
TB4-2 D1
TB4-3 D2
TB4-4 D3
TB4-5 D4
TB4-6 D5
TB4-7 D6
TB4-8 D7
TB4-9 +V
TB4-10 RTN3
TB4
TB2-1 TD
TB2-2 RD
TB2-3 SIGNAL RTN
TB2-4 485+
TB2-5 485TB2 TB2-6 SIGNAL RTN
TB2-7 RELAY1 N/C
TB2-8 RELAY2 N/O
TB2-9 RELAY1 COMM
TB2-10 RELAY2 N/C
TB2-11 RELAY2 N/O
TB2-12 RELAY2 COMM
TB3-1 RTN1
TB3-2 +5V
TB3-3 INT
TB3-4 RS
TB3 TB3-5 R/W
TB3-6 EN
TB3-7 GREEN OUT
TB3-8 RED OUT
TB3-9 BEEP OUT
TB3-10 RTN2
TB1-1 DATA 0
TB1-2 DATA 1
TB1-3 CARD PRESENT
TB1-4 DATA RTN
TB1 TB1-5 GREEN IN
TB1-6 RED IN
TB1-7 BEEP IN
TB1-8 HOLD
TB1-9 TAMPER
TB1-10 COMMON
3.28
TB1
TB5
E5
E4
SW2
SW1
SW6
SW4
11
P6
P17
P10 P11
8.00
P12
OFF
Set Tamper Latch
M ode
*Tag command is
"Set Tamper"
Tag command is
read from
EEPROM
R e - re port ID's
*Tag ID's are rereported on each
Poll
Reports only ID's
that are different
from previous
Indicator re-report
*Indicators activate
for every ID
Indicators activate
only for different
from previous
Fast indicator
duration's
Use 4X faster
indicator durations
*1X durations
Acquisition test
reports
Sends receiver and
power level test
reports - effects
Simplex output and
LCD
P2
1 P5 1 P8
P14
P24
1 P3
P16
P4
P1
P18
P9
P7
P13
11 1
P15
P20
SW3
P19
ON
R5
1 1
SWITCH #1
Report Settings
TB2
SW5
TB4
Note: Data is always 8 bits, no parity, 1 stop bit
EPP Database
Figure 5
SW1
SW2
SW3
SW4
LCD Reports
LCD reports ID and
s e n s o r me s s a g e s
*Host only control
of LCD
Te s t LCD
Te s t
*LCD. For factory
use only
P6
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A
3 of 6
Switch 3
Hardware settings
On
MaxiTrak mode
(Must remain in ON position)
Access Control Exciter
(Must remain in ON position)
Free-Running Acq
* ID acquisition is free running;
asynchronous with Host polls
Staus LED's Disable
(Must remain in ON position)
Off
Hardware Demodulator
(Must remain
in OFF
position)
Low Gain
(Must remain
in OFF
position)
8 Receivers (Not Used)
(Must remain
in OFF
position)
2nd Access Reader
(Not Used)
(Must remain
in OFF
position)
Switch 4
Initialization Settings
On
Off
Switch Over-ride
Reset Factory Defaults
EEPROM Unlock
Flash Mode Bit 0
Flash Mode Bit 1
Not Used
Not Used
Not Used
Jumper Settings
There are several configuration options available according to how the jumpers are set on the board. These jumpers control
serial input and output selections, beeper and tamper switch settings. Refer to the table on the following page for appropriate
jumper settings.
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A
4 of 6
Jumpe r B lock
Jumpe r s e tting
Functional D e s c ription
P-5
Ground s e le c t
*1-2
Always should be left in this position
P-8
+5v s e le c t
*1-2
Always should be left in this position
2-3
P-6 Input communication
protocol s e le c t
1-2
RS485 serial input s e lected
*2-3
RS232 serial input s e lected
1-2
RS485 serial output s e lected
2-3
RS232 serial output s e lected
Output path se le c tor
P7 #1- P10 #1
S e rial output A se lected
Input path se le c tor
P7 #2- P10 #2
S e rial input A s e lected
485 enable s e le c t or
P7 #3- P10 #3
485 enable A selected
Output path se le c tor
*P11 #1- P10#1
S e rial output B s e lected
Input path se le c tor
*P11 #2- P10
#2
S e rial input B s e lected
485 enable se le c tor
*P11 #3- P10
#3
485 enable B selected
1-2
The s e s hould be jumpe d whe n the maxitrak is
the last unit on the s e rial s tring from the 485
communication card
2-3
(or no jumpe r)
This setting would apply to all othe r conditions.
*1-2 jumpe d
B e e pe r enabled (audible tone will be heard with
each card or asset read)
P-9 Output communication
protocol s e le c t
P-17
RS485 Te rmination
P-18
B e e pe r enable
B e e pe r disabled
P-19
Tampe r switch select
1-2
Tampe r output will be N o rmally Ope n
2-3
Tamper output will be N o rmally Closed
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A
5 of 6
Power Supply
1. The AMR100 Property Pass Reader can be operated over the full range of 12VDC to ±
1.2V. A linear supply is recommended.
2. After the Reader and power supply are wired together, apply power to the reader.
Cover Installation
1. Place the top cover onto the base of the AMR100 Reader.
2. Secure the cover to the base. Use the flathead screw provided. The location of the top cover screw is indicated on
Figure 1.
2. Place the HID label over the screw.
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A
6 of 6

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 6
Creator                         : I:Master†5†5
Create Date                     : Monday, March 15, 1999 8:23:40 AM
Title                           : I:Master†5†5-900†5-90
Author                          : Unknown
Producer                        : Acrobat PDFWriter 3.02 for Windows
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JQ66015

Navigation menu