HID Global 607X 6071A, 6072A, 6073A FlexSmart Keypad Reader Series User Manual Flexpass Reader Installation Guide

HID Global Corporation 6071A, 6072A, 6073A FlexSmart Keypad Reader Series Flexpass Reader Installation Guide

Users Manual

  9292 Jeronimo Road  Irvine, CA 92618-1905  HID® FlexSmart™  607X Series Readers  INSTALLATION GUIDE        © 2007 HID Global Corporation.  All rights reserved.         February 5, 2006 Document Number 6075-900 Document Version B.2
6075-900, B.2 – FlexSmart™ 607X Series Installation Guide   Contents 1 Overview ............................................................................................................................................... 3 2 Mounting ............................................................................................................................................... 4 3 Wiring ................................................................................................................................................... 5 Regulatory ................................................................................................................................................... 7 Models   ................................................................................................................................................... 7 Contact ................................................................................................................................................... 8  List of Figures Figure 1 Reader Dimensions and Mounting........................................................................................................ 4 Figure 2 Keypad Reader Dimensions and Mounting .......................................................................................... 5  Page 2 of 8    February 5, 2007 © 2007 HID Global Corporation.  All rights reserved.
   FlexSmart™ 607X Series Installation Guide – 6075-900, B.2  1 Overview 1.1 Introduction The HID® FlexSmart™ readers can easily be configured at the site because the readers’ bezel can be interchangeably snapped onto the common reader module (only standard reader).  The FlexSmart readers mount on any North American standard electrical gang box or on any flat surface, with snap-on bezels. 1.2 Parts Included First, unpack the contents and become familiar with the components.  The following items will be included with FlexSmart readers: 1. Installation Guide 2.  MIFARE reader module for Slim or Wall switch 3.  Cover Bezel (reader only) 1.3 Specifications Supply Voltage  9VDC to 16VDC  Supply Current  15 / 75mA   Keypad 25 / 100mA  Input  1-line LED (red/green), 1-line buzzer Output formats  Wiegand/ABA, Application dependant  Operating Frequency  13.56MHz, 106kBaud Data Transmission  Contactless  Operating Temperature  -25oC to +55oC Non-Operating Temperature  -40oC to +70oC Operating Humidity  5% to 95% condensing  Finish  Black (Standard) Dimensions  4.30” x 1.5” x .72”  (10.9 x 3.8 x 1.8 cm) 4.70” x 2.9” x 1.1”  (11.9 x 7.4 x 2.8 cm) Weight  4 oz (113g)  keypad 12 oz (340g) February 5, 2007    Page 3 of 8 © 2007 HID Global Corporation.  All rights reserved.
6075-900, B.2 – FlexSmart™ 607X Series Installation Guide   1.4 Identifying the Reader Format The reader format is found on the ID label (see below), which is located on the reader electronics module.  Reader Format 2 Mounting  Figure 1 Reader Dimensions and Mounting Page 4 of 8    February 5, 2007 © 2007 HID Global Corporation.  All rights reserved.
   FlexSmart™ 607X Series Installation Guide – 6075-900, B.2  Figure 2 Keypad Reader Dimensions and Mounting 2.1 Mullion Mounting The following describes how the readers mount to a mullion.  1.  Drill two holes 6-32 or M-3 sheet metal or thread forming screws 3.3” (8.38 cm) apart.  2.  Locate and drill a 0.375” (0.95 cm) hole for the reader cable.  3.  Route the cable through the center hole to the controller.  4.  Using the two 6-32 or M-3 screws, attach the reader to the first two mounting holes.  5.  Once the reader module is screwed in place, snap on the bezel. 3 Wiring 3.1 Cable Types and Maximum Lengths The MIFARE readers require a minimum voltage of 9.0 VDC. Voltage drops, caused by the cable resistance, can be made by increasing the power supply voltage.  CAUTION: DO NOT SET THE POWER SUPPLY VOLTAGE TO HIGHER THAN 16 VDC.  CAUTION: DO NOT USE CABLES WITH GAUGES SMALLER THAN 24 AWG: February 5, 2007    Page 5 of 8 © 2007 HID Global Corporation.  All rights reserved.
6075-900, B.2 – FlexSmart™ 607X Series Installation Guide   The following are recommended cable types and maximum cable lengths for a cable connecting the power supply to the reader. Cable Type  Maximum Cable Length 24 AWG (0.60mm), three conductors, with an overall foil shield, 9533 or equivalent.  200’ (61 m) 22 AWG (0.80mm), two conductors, with an overall foil shield, Alpha 5192 or equivalent.  300’ (91 m) 18 AWG (1.20mm), two conductors, with an overall foil shield, 5836 or equivalent.   500’ (152 m) The following are recommended wiring types at various maximum distances. Variations in distances require different wire gauges, because of system data termination differences. Contact your system manufacturer for its exact requirements. Installation should be in accordance with National Electric Code ANSI/NFPA 70. Cable Type  Maximum Cable Length 22 AWG (0.80mm), six or eight conductor, with an overall foil shield, Alpha 5196, 5198 or equivalent.   500’(152 m) 18 AWG (1.20mm), six or eight conductor, with an overall foil shield, Alpha 5386, 5388 or equivalent.  500’ (152m) 3.2 Grounding Connect the reader directly to an earth ground (an earth ground can be established by driving a copper clad ground rod into the earth). Make certain the DC resistance between your established earth ground and the system ground is 50 Ohms or less. If a direct connection to a ground rod is not possible, connect the reader to an earth grounded cold water metal pipe (do not connect to a copper fire sprinkler system because it may have non-conductive couplings) or steel frames (building beams) that connect to earth. Connection of the shield/drain to an earth ground will provide greater ESD protection of the reader.  Prevent ground loops by connecting both the cable shield and the negative line of the power supply to one common earth ground point. Connecting different points to separate earth grounds may result in a ground loop.  Note: For the heavy duty keypad readers, the Shield/drain wire should be floating at the power supply. Note: Ground loops may cause poor read range and communication line interference, resulting in no code or improper code seen by the controller. Reader Defaults   Reader Wiring   Card read (LED, beep & backlight)    Red  +12Vdc One-line control (bi-colour LED)    Black  0Vdc Keypad Defaults    Green  Data 0/Strobe Key-press (LED, beep & backlight)    White  Data 1/Data 1 0001  2 0010  3 0011    Brown  LED Control 4 0100  5 0101  6 0110    Blue  Beeper Control 7 0111  8 1000  9 1001    Orange  Not Used Θ1010  0 0000  # 1011    Shield/drain  Door controller earth ground  Page 6 of 8    February 5, 2007 © 2007 HID Global Corporation.  All rights reserved.
   FlexSmart™ 607X Series Installation Guide – 6075-900, B.2 Notes: •  Keypad outputs only available •  The system must have a single earth ground point. • As shown, do not connect shield (screen) wire at reader cable splice. •  For open collector (non-terminated output), consult your system manufacturer for correct cable length and type. Regulatory FCC This device complies with part 15 of the FCC rules.  Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. UL This reader is intended to be used with UL294 Listed Control Equipment. CE Hereby, HID declares that this proximity reader is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Models Readers 6075  HID Format MIFARE Reader 6076  Custom MIFARE Reader 6077  Custom DESFire Reader Keypad Readers 6071  HID Format MIFARE Reader 6072  Custom MIFARE Reader 6073  Custom DESFire Reader February 5, 2007    Page 7 of 8 © 2007 HID Global Corporation.  All rights reserved.
6075-900, B.2 – FlexSmart™ 607X Series Installation Guide    Contact Americas HID Corporation (California, USA) Email: tech@hidcorp.com   main: (949) 598-1600 support: 1-800-237-7769 fax: (949) 598-1690 Europe, Middle East and Africa HID Corporation, Ltd. (Haverhill, UK) email: eusupport@hidcorp.com   main: +44 (0) 1440 714 850 support: +44 (0) 1440 711 822 fax number: +44 (0) 1440 714 840 Asia-Pacific HID Asia Pacific Ltd. (Hong Kong) email: asiasupport@hidcorp.com   main: (852) 3160 9800 support: (852) 3160 9802 fax : (852) 3160 4809  Page 8 of 8    February 5, 2007 © 2007 HID Global Corporation.  All rights reserved.