HID Global 607X 6071A, 6072A, 6073A FlexSmart Keypad Reader Series User Manual Flexpass Reader Installation Guide
HID Global Corporation 6071A, 6072A, 6073A FlexSmart Keypad Reader Series Flexpass Reader Installation Guide
Users Manual
9292 Jeronimo Road Irvine, CA 92618-1905 HID® FlexSmart™ 607X Series Readers INSTALLATION GUIDE © 2007 HID Global Corporation. All rights reserved. February 5, 2006 Document Number 6075-900 Document Version B.2 6075-900, B.2 – FlexSmart™ 607X Series Installation Guide Contents Overview ............................................................................................................................................... 3 Mounting ............................................................................................................................................... 4 Wiring ................................................................................................................................................... 5 Regulatory ................................................................................................................................................... 7 Models ................................................................................................................................................... 7 Contact ................................................................................................................................................... 8 List of Figures Figure 1 Reader Dimensions and Mounting........................................................................................................ 4 Figure 2 Keypad Reader Dimensions and Mounting .......................................................................................... 5 Page 2 of 8 February 5, 2007 © 2007 HID Global Corporation. All rights reserved. FlexSmart™ 607X Series Installation Guide – 6075-900, B.2 1.1 Overview Introduction The HID® FlexSmart™ readers can easily be configured at the site because the readers’ bezel can be interchangeably snapped onto the common reader module (only standard reader). The FlexSmart readers mount on any North American standard electrical gang box or on any flat surface, with snap-on bezels. 1.2 Parts Included First, unpack the contents and become familiar with the components. The following items will be included with FlexSmart readers: 1. Installation Guide 2. MIFARE reader module for Slim or Wall switch 3. Cover Bezel (reader only) 1.3 Specifications Supply Voltage 9VDC to 16VDC Supply Current 15 / 75mA Keypad 25 / 100mA Input 1-line LED (red/green), 1-line buzzer Output formats Wiegand/ABA, Application dependant Operating Frequency 13.56MHz, 106kBaud Data Transmission Contactless Operating Temperature -25oC to +55oC Non-Operating Temperature -40oC to +70oC Operating Humidity 5% to 95% condensing Finish Black (Standard) Dimensions 4.30” x 1.5” x .72” (10.9 x 3.8 x 1.8 cm) 4.70” x 2.9” x 1.1” (11.9 x 7.4 x 2.8 cm) Weight 4 oz (113g) keypad 12 oz (340g) February 5, 2007 Page 3 of 8 © 2007 HID Global Corporation. All rights reserved. 6075-900, B.2 – FlexSmart™ 607X Series Installation Guide 1.4 Identifying the Reader Format The reader format is found on the ID label (see below), which is located on the reader electronics module. Reader Format Mounting Figure 1 Reader Dimensions and Mounting Page 4 of 8 February 5, 2007 © 2007 HID Global Corporation. All rights reserved. FlexSmart™ 607X Series Installation Guide – 6075-900, B.2 Figure 2 Keypad Reader Dimensions and Mounting 2.1 Mullion Mounting The following describes how the readers mount to a mullion. 1. Drill two holes 6-32 or M-3 sheet metal or thread forming screws 3.3” (8.38 cm) apart. 2. Locate and drill a 0.375” (0.95 cm) hole for the reader cable. 3. Route the cable through the center hole to the controller. 4. Using the two 6-32 or M-3 screws, attach the reader to the first two mounting holes. 5. Once the reader module is screwed in place, snap on the bezel. 3.1 Wiring Cable Types and Maximum Lengths The MIFARE readers require a minimum voltage of 9.0 VDC. Voltage drops, caused by the cable resistance, can be made by increasing the power supply voltage. CAUTION: DO NOT SET THE POWER SUPPLY VOLTAGE TO HIGHER THAN 16 VDC. CAUTION: DO NOT USE CABLES WITH GAUGES SMALLER THAN 24 AWG: February 5, 2007 Page 5 of 8 © 2007 HID Global Corporation. All rights reserved. 6075-900, B.2 – FlexSmart™ 607X Series Installation Guide The following are recommended cable types and maximum cable lengths for a cable connecting the power supply to the reader. Cable Type Maximum Cable Length 24 AWG (0.60mm), three conductors, with an overall foil shield, 9533 or equivalent. 200’ (61 m) 22 AWG (0.80mm), two conductors, with an overall foil shield, Alpha 5192 or equivalent. 300’ (91 m) 18 AWG (1.20mm), two conductors, with an overall foil shield, 5836 or equivalent. 500’ (152 m) The following are recommended wiring types at various maximum distances. Variations in distances require different wire gauges, because of system data termination differences. Contact your system manufacturer for its exact requirements. Installation should be in accordance with National Electric Code ANSI/NFPA 70. Cable Type 3.2 Maximum Cable Length 22 AWG (0.80mm), six or eight conductor, with an overall foil shield, Alpha 5196, 5198 or equivalent. 500’(152 m) 18 AWG (1.20mm), six or eight conductor, with an overall foil shield, Alpha 5386, 5388 or equivalent. 500’ (152m) Grounding Connect the reader directly to an earth ground (an earth ground can be established by driving a copper clad ground rod into the earth). Make certain the DC resistance between your established earth ground and the system ground is 50 Ohms or less. If a direct connection to a ground rod is not possible, connect the reader to an earth grounded cold water metal pipe (do not connect to a copper fire sprinkler system because it may have non-conductive couplings) or steel frames (building beams) that connect to earth. Connection of the shield/drain to an earth ground will provide greater ESD protection of the reader. Prevent ground loops by connecting both the cable shield and the negative line of the power supply to one common earth ground point. Connecting different points to separate earth grounds may result in a ground loop. Note: For the heavy duty keypad readers, the Shield/drain wire should be floating at the power supply. Note: Ground loops may cause poor read range and communication line interference, resulting in no code or improper code seen by the controller. Reader Defaults Card read (LED, beep & backlight) One-line control (bi-colour LED) Keypad Defaults Key-press (LED, beep & backlight) 1 0001 2 0010 3 0011 4 0100 5 0101 6 0110 7 0111 8 1000 9 1001 0 0000 # 1011 Θ1010 Reader Wiring Red Black Green White Brown Blue Orange Shield/drain +12Vdc 0Vdc Data 0/Strobe Data 1/Data LED Control Beeper Control Not Used Door controller earth ground Page 6 of 8 February 5, 2007 © 2007 HID Global Corporation. All rights reserved. FlexSmart™ 607X Series Installation Guide – 6075-900, B.2 Notes: • Keypad outputs only available • The system must have a single earth ground point. • As shown, do not connect shield (screen) wire at reader cable splice. • For open collector (non-terminated output), consult your system manufacturer for correct cable length and type. Regulatory FCC This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. UL This reader is intended to be used with UL294 Listed Control Equipment. CE Hereby, HID declares that this proximity reader is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Models Readers 6075 HID Format MIFARE Reader 6076 Custom MIFARE Reader 6077 Custom DESFire Reader Keypad Readers 6071 HID Format MIFARE Reader 6072 Custom MIFARE Reader 6073 Custom DESFire Reader February 5, 2007 Page 7 of 8 © 2007 HID Global Corporation. All rights reserved. 6075-900, B.2 – FlexSmart™ 607X Series Installation Guide Contact Americas HID Corporation (California, USA) Email: tech@hidcorp.com main: (949) 598-1600 support: 1-800-237-7769 fax: (949) 598-1690 Europe, Middle East and Africa HID Corporation, Ltd. (Haverhill, UK) email: eusupport@hidcorp.com main: +44 (0) 1440 714 850 support: +44 (0) 1440 711 822 fax number: +44 (0) 1440 714 840 Asia-Pacific HID Asia Pacific Ltd. (Hong Kong) email: asiasupport@hidcorp.com main: (852) 3160 9800 support: (852) 3160 9802 fax : (852) 3160 4809 Page 8 of 8 February 5, 2007 © 2007 HID Global Corporation. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Company : Motorola WSSD Source Modified : D:20070205214830 Creator Tool : Acrobat PDFMaker 7.0.7 for Word Modify Date : 2007:02:05 14:52:59-07:00 Create Date : 2007:02:05 14:48:58-07:00 Metadata Date : 2007:02:05 14:52:59-07:00 Document ID : uuid:1a2729a9-da0e-4c32-90a1-de36342ca0f4 Instance ID : uuid:a9a1a045-8282-4e68-b8a9-3f855c72f179 Version ID : 3 Format : application/pdf Title : Flexpass Reader Installation Guide Creator : Motorola Subject : Headline : Page Count : 8 Page Layout : SinglePage Author : MotorolaEXIF Metadata provided by EXIF.tools