HID Global 607XA 6074A HID MIFARE Wiegand Reader User Manual 474681

HID Global Corporation 6074A HID MIFARE Wiegand Reader 474681

Users Manual

  REV DESCRIPTION DATE APPROVED 1  6074A INITIAL  RELEASE     2   ADDED FCC STATEMENT, FIX LED INPUT                                                       NOTE:  Cover sheet is for Revision Control only, and is not to be sent with document.  REV                    SHEET 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 REV                    SHEET 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 REV STATUS  A  A  A  A  A  A  A                        OF SHEETS  0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 TOLERANCES APPROVALS  DATE  HID CORPORATION .XX = +/- .03”      IRVINE, CALIFORNIA .XXX = +/- .010”      Installation Manual ANGLES = +/- 1°     MIFARE® WIEGAND Reader MATERIAL N/A       FINISH N/A      P/N               6074-901  REV 2 SCALE N/A      SIZE          A  SHEET 0 OF 6
____________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road   Irvine, CA 92618-1905 USA  TEL (714) 598-1600  (800) 237-7769  FAX  (714) 598-1690 Web page, E-mail - www.prox.com MIFARE Wiegand Reader Installation Manual 6074-901 REV 2                                     1 of 5                   Installation Manual – 6074-901 Rev A HID MIFARE WIEGAND READER 6074A
____________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road   Irvine, CA 92618-1905 USA  TEL (714) 598-1600  (800) 237-7769  FAX  (714) 598-1690 Web page, E-mail - www.prox.com MIFARE Wiegand Reader Installation Manual 6074-901 REV 2                                     2 of 5 MIFARE WIEGAND Reader Installation Manual  System Overview The MIFARE Wiegand Reader is a self contained proximity Reader, frequently used in Access Control Systems.  The antenna and all associated electronics are assembled in a polycarbonate housing.  The Reader contains a micro-controller unit that controls an RF field that is generated at 13.56MHz. The Reader has a sensitive receiver circuit that detects ID card data and passes it along to the micro-controller for decoding. The Reader output is configured in the "Wiegand" style electrical interface for model 6074A.  The Reader has a single Bicolor LED that will emit red, green or amber colors.  Installation of the MIFARE Wiegand Reader consists of mounting the Reader and connecting the cable to the Host via the Pigtail. Operation Access Cards are to be presented to the front of the Reader.  The LED is red when ready to read an ID card.  The LED turns green when the card is read and a message is transmitted to the Host computer or interface panel.  When the system is ready for another card, the LED returns to red.  The LED is flashed green and the Beeper is activated for 500 milliseconds when they are controlled by the internal micro-controller.  The operation of the LED and beeper is often controlled by the Host panel.  If Host controlled, the operation will deviate from Host to Host.  The MIFARE Wiegand reader’s default configuration can accept green and beeper input control lines that allows control of green LED and beeper only (Red input is not supported). Parts List  Quantity 1) MIFARE Wiegand Reader  1 (included) 2) #6-32 x 1" self tapping, Type T or 23  2 (included) 3) This Installation Sheet  1 (included) 4) Wire Splice   9 (installer supplied) 5) Grommet   1 Recommended (installer supplied) 6) DC Power Supply  10.0 to 14.0VDC, 50mA   1 (installer supplied) 7) Cable, 9 conductor , 22 AWG  Up to 500ft. (installer supplied) Alpha 1295C   See Cable Notes Installation Procedure: 1.  Determine an appropriate mounting position for the Reader. Drill two 7/64th (.109) Inch holes for mounting the Reader to the surface (see figure 1).  Drill a 3/8 to 1.0 Inch hole for the cable.  Place a grommet around the edge of the hole.   Route the interface cable from the Reader and/or power supply to the Host.  Check all electrical codes for proper cable installation. 2.   The  MIFARE Wiegand Reader is a Pigtail style with a 18” - 9 conductor cable. Prepare the new cable by cutting the cable jacket back 1-1/4” and strip the wires ¼”.  Splice the cable and the pigtail  together and seal the splice.  Trim and cover all conductors that are not used. 3.  Connect the Reader and Host together according to the wiring diagram with figure 2 and the Host installation guide.  The legend for wiring is color coded (according to the "Wiegand Standard") for the recommended cable. 4.   After wiring the Reader and power supply, the Reader is ready to be tested.  Power up the Reader and the red LED will be on when operating under the factory default reader configuration. This indicates that the micro-controller unit is working properly.  Present an ID card to the Reader and the LED should momentarily turn green, indicating a read of the card.  If the Reader LED is controlled by the Host refer to the Host description of the LED operation. 5.   Mount the Reader with the provided screws when mounting onto metal mullions or junction boxes.  On other materials use the appropriate fastener.
____________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road   Irvine, CA 92618-1905 USA  TEL (714) 598-1600  (800) 237-7769  FAX  (714) 598-1690 Web page, E-mail - www.prox.com MIFARE Wiegand Reader Installation Manual 6074-901 REV 2                                     3 of 5 Dimension Diagrams, front, side and back views                            FIGURE 1   Wire Connections 1  2  3  4  5  6  7  8  9  10 +DC Ground Data0 Data1 Shield  Ground Green LED Red  LED Beeper ---  --- Red Black Green White Drain Orange Brown Yellow  ---  ---   FIGURE 2 Cable Notes 1) Wiegand - +DC, Ground, Shield Ground, Data0 and Data1 are required for Wiegand Operation. All others (Green LED, Red LED, and Beeper) are optional. 2) When using a separate power supply for the MIFARE Wiegand Reader, the power supply and Host should have a common ground (voltage reference).  3) If the Host is controlling the beeper or the LEDs are configured for the external LED mode, additional conductors will be required.  The recommended cables are Alpha 1295C, 1296C, 1297C, 1298C and 1299C, which are five, six, seven, eight and nine conductors respectively. Larger wire gauges are acceptable. The wire is to be stranded with an overall foil shield plus the drain wire.  4) The Cable shield (drain) should be connected to the earth ground at the panel or power supply end of the cable. Also, for emissions compliance, tie earth ground and common together at the power supply.  This configuration is the best for shielding the reader cable from external interference and reducing the likelihood of the Reader causing interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
____________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road   Irvine, CA 92618-1905 USA  TEL (714) 598-1600  (800) 237-7769  FAX  (714) 598-1690 Web page, E-mail - www.prox.com MIFARE Wiegand Reader Installation Manual 6074-901 REV 2                                     4 of 5  Testing and Operation When power is applied to the reader the LED will turn – on Red. This indicates that the microcontroller is operating properly. Present an ID card to the reader. The LED will momentarily turn green while the beeper beeps once, indicating that the card was read successfully. In normal operation, the Red LED is normally on and the Green LED flashes on a valid card read.  The Green LED and Beeper respond when their respective user input line is pulled low.  There is no operation for the Red LED user input. Please note that typical read range for MIFARE cards is 1.5 – 2.0” (37-50 mm). Card Compatibility The HID MIFARE Reader reads serial number data from these cards: HID MIFARE, Any Philips compatible MIFARE Standard  contactless smart card. The reader will read the MIFARE Card Serial Number only from all MIFARE cards, including MIFARE Lite and MIFARE Pro cards.   *The HID MIFARE reader will not read 125 kHz HID Proximity cards.   CSN Read Only Mode In CSN Only mode, the reader reads the 32-bit  MIFARE random card serial number (CSN or UID) from any MIFARE card, including MIFARE Lite, MIFARE Standard and MIFARE Pro, outputting that data in a 40-bit Wiegand format - 32-bit CSN + 8 bit checksum format.    Sector Read Only Mode In Sector Read Only Mode the reader reads and outputs a specified number of bits from a specified sector based on reader configuration.  The following reader attributes can be configured at the factory to meet individual needs.  •  Application sector (0 – 15)  •  Application Block (0-2) • Sector Key •  Number of Bits Output (1-128) •  Starting Bit Number (0-127) •  Audio/Visual feedback (ON/Off) Product Configuration/Ordering Options   6074  A   X    X   XX -XXXX Y   Customer Custom Artwork or Firmware Number -  1 through 9, A through Z    Customer Custom Number    Configuration Options - (00 standard)    Standard Hardware Options - P = Pigtail    Color - G = Gray    Current Revision Letter    Model Number 6074 = MIFARE Wiegand                   ¾ Standard Wiegand Part Number = 6074AGP00 is a MIFARE Wiegand, Gray Standard (1”) housing, Potted, with 9 conductor, 18” Pigtail.
____________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road   Irvine, CA 92618-1905 USA  TEL (714) 598-1600  (800) 237-7769  FAX  (714) 598-1690 Web page, E-mail - www.prox.com MIFARE Wiegand Reader Installation Manual 6074-901 REV 2                                     2 of 5 Product Specifications Read Distance ¾ Overall Operating Limits (10VDC - minimum)  1.0-1.5 inches (2.5-3.8 cm) ¾ Non-Metallic Mounting (12VDC - typical)  1.0-1.5 inches (2.5-3.8 cm) ¾ Mounted on Metal (12VDC - typical)  1.0-2.5 inches (2.5-3.8 cm)  Environmental Characteristics ¾ Operating Temperature Range  -30oC to 65oC (-22oF to 150oF) ¾ Storage Temperature Range  -40oC to 85oC (-40oF to 185oF) ¾ Operating Humidity Range  5% to 95% non-condensing ¾ Operating Vibration Limit  .04 g2/Hz 20-2000Hz ¾ Operating Shock Limit  30g, 11mS, Half Sine ¾ Potting Material  UL Recognized Filled Polyurethane ¾ Enclosure Material  UL Recognized Lexan Polycarbonate ¾ Potted Weight   8.2oz (228grms)  Power Requirements ¾ Power supply  Linear type recommended ¾ Operating Voltage Range (+DC)  10.0VDC -14.0VDC ¾ Absolute Maximum (+DC non-operating)  14.0VDC ¾ Maximum Average Current at 12V  60mA ¾ Transient Protection (all terminals)  8,000 volts ¾ Reverse Voltage Protection  -15V on all I/O and -35 for power lines ¾ Input Voltage (maximum data-0/1 lines)  15.0VDC ¾ Input Voltage (maximum interface lines)  15.0VDC  Operating Parameters ¾ Excitation Frequency  13.56MHz ¾ Read and Report Speed (26 bit Wiegand Card)  200mS (1K card) + output data ¾ Maximum Cable Distance to Host  500 feet (152 meters) ¾ LED Type                                                                      Bi-colored Red/Green ¾ LED Operation (host control of red/green)  <.5V on LED control line ¾ Beeper Operation (host control)  <.5V on beeper line ¾ Beeper Control (default)  Beeper enabled   FCC Compliance Statement:  This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  NOTE: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES.  ALL LOCAL, STATE AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE.

Navigation menu