HID Global ICLASSU90 iCLASS SE U90 Reader User Manual iCLASS SE U90 Reader Installation Guide

HID Global Corporation iCLASS SE U90 Reader iCLASS SE U90 Reader Installation Guide

User Manual

 ACCESS flexibility.Ultra High FrequencyiCLASS SE®INSTALLATION GUIDEU90 (U90.915 & U90.865)ReaderPLT-01545, A.0
iCLASS SE INSTALLATION GUIDE2PLT-01545, A.0U90 (U90.915 & U90.865)© 2014 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.SpecificationsParts List Parts1 - iCLASS Reader 1 - Installation Guide2 - #6-32 x .375” Phillips machine screws 2 - #6-32 x .375” Spanner security screw, anti-tamper 2 - 7-pin Terminal connectors 1 - 10-pin Terminal connector1 - Mounting Gasket1 - Back Boxrecommended• Cable, 5-9 conductor (Wiegand or clock-and-data)• Linear DC Power supply• Metal or plastic junction box • Security Tool (for anti-tamper screw) HID 04-0001-03• Drill with various bits for mounting hardware• Mounting HardwareUL Reference Number Decipheringx1  Reader Colors: K = Blackx2  Wiring:  T = Terminalx3  Communications: N = No Module                             PRODUCT BASE PART NUMBERINPUT VOLTAGE (VDC)CURRENT OPERATING TEMPERATURE CABLE LENGTH UL REF NUMBERStandby AVG1Max AVG2PEAK3U90 960N12 VDC 320mA 400mA 1.0 A-30° to 150° F(-35° to 65° C)Power Supply Lines40 ft (12 m)  - 22 AWG100 ft (30 m)  - 18 AWGCommunication LinesWiegand / Clock-and-Data500 ft (152 m) - 22 AWGRS-4854,000 ft (1,219 m) - 24 AWGU90Ax1x2x324 VDC 160mA 200mA 0.5 A1  Standby AVG - RMS current draw without a card in the RF eld.2  Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.3  Peak - highest instantaneous current draw during RF communication.RelaysThree (3) each dry relays for operating external audio and visual indicators. Not to be used for Access Control. Rated 30VDC, 2A resistive.
INSTALLATION GUIDE 3PLT-01545, A.0 iCLASS SEU90 (U90.915 & U90.865)© 2014 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.Mounting1There are many options for mounting surfaces (pole, concrete, metal, wall bracket, etc.). See the iCLASS SE U90 Reader User Guide for detailed information.100 75VESA CONDUITUSJBOXEUJBOXEUJBOXEUJBOXEUJBOXUSJBOX75 1007510075100200200 200200Mounting holes need to be drilled to mate with the mount selected for the site.Modify the gasket to the match the large holes on the mounting plate and to match the area between the mount and the box, to create a seal against the elements (see below).Attach the box with the gasket to the mountTrim Gasket to match the contact area
iCLASS SE INSTALLATION GUIDE4PLT-01545, A.0U90 (U90.915 & U90.865)© 2014 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.ATTENTIONObserve precautions for handlingELECTROSTATIC SENSITIVE DEVICESWiring2*  Tamper Output - When activated, output synchronizes to ground (default).**  Dependent upon reader conguration. See the HTOG for Wiegand and Clock-in-Data congurations.Terminal Description Terminal Description Terminal DescriptionP1-1 Beeper Input (BEEP) P2-1   GPIO4 (RS485-Y / TXA)  P3-1 Earth GroundP1-2 LED Input (GRN) P2-2   GPIO3 (RS485-Z / TXB)  P3-2 Normally Closed (NC) - Relay 1P1-3 Ground (GND) P2-3 **  Wiegand Data 0 / Data (DATA0/DATA) P3-3 Common (COM) - Relay 1P1-4 +VDC P2-4 **  Wiegand Data 1 / Clock (DATA1/CLK) P3-4 Normally Open (NO) - Relay 1P1-5 Unused (DRAIN) P2-5 *  Open Collector Output / Tamper (OC/TMPR) P3-5 Normally Closed (NC) - Relay 2P1-6 LED Input (RED) P2-6   GPIO2 (RS232-R / RS485-RXB) P3-6 Common (COM) - Relay 2P1-7 Hold Input (HOLD) P2-7   GPIO1 (RS232-T / RS485-RXA) P3-7 Normally Open (NO) - Relay 2P3-8 Normally Closed (NC) - Relay 3P3-9 Common (COM) - Relay 3P3-10 Normally Open (NO) - Relay 3
INSTALLATION GUIDE 5PLT-01545, A.0 iCLASS SEU90 (U90.915 & U90.865)© 2014 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.Install Reader to Backbox3Power & Testing4Basic test of a cardTurn power onLED is under the trap doorLED will be GreenNote: This is tested with a card mounted in a vehicle and driven by the reader.LED will be red (under the trap door)Configurable Features•  Open Collector Output - Controls an external device (16 VDC Max) operating in Host Mode only. Sink - 40mA / Source - 1mA. See the iCLASS Application Note for details. •  Optical Tamper - Reader is configurable for Optical Tamper. Once activated, and when the reader is removed from the mounting box, the Optical Tamper is activated. Contact HID Technical Support for Optical Tamper options. See iCLASS SE U90 User Guide. •  Hold Input - when asserted, this line either buffers a card or disables a card read until released, as configured.
hidglobal.comACCESS experience.Americas & Corporate611 Center Ridge DriveAustin, TX 78753USASupport:   866 607 7339Fax:   949 732 2120For additional oces around the world, see www.hidglobal.com corporate oces.HID Global Customer Support: support.hidglobal.comAsia Pacific19/F 625 King’s RoadNorthPoint, Island EastHong KongSupport:   852 3160 9833Fax:   852 3160 4809Europe, Middle East & AfricaPhoenix RoadHaverhill, Suolk CB9 7AEEnglandSupport:  +44 1440 711 822Fax:   +44 1440 714 840HID GlobalBrazilCondomínio Business CenterSt. Ermano Marchetti, 1435Galpão A2 CEP 05038-001Lapa - São Paulo/SPBrazilSupport:   55 11 5514-7100US Patents: See www.hidglobal.com/patentsCheck reader label for current regulatory approvals.ULConnect only to a Listed Access Control / Burglary power-limited power supply.  These readers are intended  to be used with listed (UL294) control equipment.Only Wiegand and RS-485 communications have been evaluated by UL.CAUTION: Any changes or modifcations to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.FCCThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interfer-ence received, including interference that may cause undesired operation.FCC RF Exposure StatementThis equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the  radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antennaCanada Radio CertificationThis device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.CE MarkingHID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications.HID GLOBAL, HID, the HID logo, and iCLASS SE, are the trademarks or registered trademarks of HID Global Corporation, or its licensors, in the U.S. and other countries.PLT-01545 A.0© 2014 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.Equipment8T29ACC Control READERGeneral SignalingEquipment