HID Global ICLASSU90 iCLASS SE U90 Reader User Manual iCLASS SE U90 Reader Installation Guide

HID Global Corporation iCLASS SE U90 Reader iCLASS SE U90 Reader Installation Guide

User Manual

Download: HID Global ICLASSU90 iCLASS SE U90 Reader User Manual iCLASS SE U90 Reader Installation Guide
Mirror Download [FCC.gov]HID Global ICLASSU90 iCLASS SE U90 Reader User Manual iCLASS SE U90 Reader Installation Guide
Document ID2360366
Application IDsw1Zn8UTKa/qwx+NsS0nEw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize118.66kB (1483237 bits)
Date Submitted2014-08-15 00:00:00
Date Available2014-08-15 00:00:00
Creation Date2014-08-13 15:58:32
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2014-08-14 11:48:31
Document TitleiCLASS SE U90 Reader Installation Guide
Document CreatorAdobe InDesign CS6 (Windows)
Document Author: heriksen

ACCESS flexibility.
Ultra High Frequency
U90 (U90.915 & U90.865)
Reader
iCLASS SE
®
INSTALLATION GUIDE
PLT-01545, A.0
iCLASS SE
U90 (U90.915 & U90.865)
PLT-01545, A.0
Parts List
Parts
iCLASS Reader
Installation Guide
#6-32 x .375” Phillips machine screws
#6-32 x .375” Spanner security screw, anti-tamper
7-pin Terminal connectors
10-pin Terminal connector
Mounting Gasket
Back Box
Recommended
• Cable, 5-9 conductor (Wiegand or clock-and-data)
• Linear DC Power supply
• Metal or plastic junction box
• Security Tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting Hardware
Specifications
PART
PRODUCT BASE
NUMBER
CURRENT
INPUT
VOLTAGE (VDC) Standby Max
AVG1
AVG2 PEAK
12 VDC
U90
320mA
400mA
160mA
200mA
CABLE LENGTH
-30° to 150° F
(-35° to 65° C)
Power Supply Lines
40 ft (12 m)
- 22 AWG
100 ft (30 m) - 18 AWG
Communication Lines
Wiegand / Clock-and-Data
500 ft (152 m) - 22 AWG
RS-485
4,000 ft (1,219 m) - 24 AWG
1.0 A
960N
24 VDC
OPERATING
TEMPERATURE
0.5 A
Standby AVG - RMS current draw without a card in the RF field.
Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.
Peak - highest instantaneous current draw during RF communication.
UL REF
NUMBER
U90Ax1x2x3
UL Reference Number Deciphering
x1 Reader Colors: K = Black
x2 Wiring:
T = Terminal
x3 Communications: N = No Module
Relays
Three (3) each dry relays for operating external audio and visual indicators. Not to be used for Access Control. Rated 30VDC, 2A
resistive.
INSTALLATION GUIDE
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
U90 (U90.915 & U90.865)
PLT-01545, A.0
Mounting
iCLASS SE
There are many options for mounting surfaces (pole, concrete, metal,
wall bracket, etc.). See the iCLASS SE U90 Reader User Guide for
detailed information.
200
200
VESA
CONDUIT
US
JBOX
100
75
75
100
EU
JBOX
EU
JBOX
EU
JBOX
EU
JBOX
75
100
200
US
JBOX
75
100
200
Mounting holes need to be drilled to mate with the mount
selected for the site.
Modify the gasket to the match the large holes on the
mounting plate and to match the area between the mount
and the box, to create a seal against the elements (see
below).
Trim Gasket to match the contact area
Attach the box with the gasket to the mount
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
INSTALLATION GUIDE
iCLASS SE
U90 (U90.915 & U90.865)
PLT-01545, A.0
Wiring
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Terminal
**
Description
Terminal
Description
Terminal
Description
GPIO4 (RS485-Y / TXA)
P3-1
Earth Ground
GPIO3 (RS485-Z / TXB)
P3-2
Normally Closed (NC) - Relay 1
P3-3
Common (COM) - Relay 1
P1-1
Beeper Input (BEEP)
P2-1
P1-2
LED Input (GRN)
P2-2
P1-3
Ground (GND)
P2-3
** Wiegand Data 0 / Data (DATA0/DATA)
P1-4
+VDC
P2-4
** Wiegand Data 1 / Clock (DATA1/CLK)
P3-4
Normally Open (NO) - Relay 1
P1-5
Unused (DRAIN)
P2-5
Open Collector Output / Tamper (OC/TMPR)
P3-5
Normally Closed (NC) - Relay 2
P1-6
LED Input (RED)
P2-6
GPIO2 (RS232-R / RS485-RXB)
P3-6
Common (COM) - Relay 2
P1-7
Hold Input (HOLD)
P2-7
GPIO1 (RS232-T / RS485-RXA)
P3-7
Normally Open (NO) - Relay 2
P3-8
Normally Closed (NC) - Relay 3
P3-9
Common (COM) - Relay 3
P3-10
Normally Open (NO) - Relay 3
Tamper Output - When activated, output synchronizes to ground (default).
Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations.
INSTALLATION GUIDE
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
U90 (U90.915 & U90.865)
PLT-01545, A.0
Install Reader to Backbox
Power & Testing
Turn power on
iCLASS SE
Basic test of a card
LED is under the trap door
LED will be red
(under the trap door)
LED will be Green
Note: This is tested with a
card mounted in a vehicle and
driven by the reader.
Configurable Features
•
•
•
Open Collector Output - Controls an external device (16 VDC Max) operating in Host Mode only. Sink - 40mA / Source - 1mA. See the iCLASS Application Note for details.
Optical Tamper - Reader is configurable for Optical Tamper. Once activated, and when the reader is removed from the mounting box, the Optical Tamper is activated. Contact HID Technical Support
for Optical Tamper options. See iCLASS SE U90 User Guide.
Hold Input - when asserted, this line either buffers a card or disables a card read until released, as configured.
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
INSTALLATION GUIDE
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control equipment.
Only Wiegand and RS-485 communications have been evaluated by UL.
CAUTION: Any changes or modifcations to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the
radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
CE Marking
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.
Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications.
ACCESS experience.
hidglobal.com
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
HID Global
HID GLOBAL, HID, the HID logo, and iCLASS SE, are the trademarks or registered
trademarks of HID Global Corporation, or its licensors, in the U.S. and other
countries.
PLT-01545 A.0
US Patents: See www.hidglobal.com/patents
Check reader label for current regulatory
approvals.
Americas & Corporate
Asia Pacific
Europe, Middle East & Africa
Brazil
611 Center Ridge Drive
Austin, TX 78753
USA
Support: 866 607 7339
Fax:
949 732 2120
19/F 625 King’s Road
NorthPoint, Island East
Hong Kong
Support: 852 3160 9833
Fax:
852 3160 4809
Phoenix Road
Haverhill, Suffolk CB9 7AE
England
Support: +44 1440 711 822
Fax:
+44 1440 714 840
Condomínio Business Center
St. Ermano Marchetti, 1435
Galpão A2 CEP 05038-001
Lapa - São Paulo/SP
Brazil
Support: 55 11 5514-7100
For additional offices around the world, see www.hidglobal.com corporate offices.
HID Global Customer Support: support.hidglobal.com
Equipment
8T29
ACC Control READER
General Signaling
Equipment

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Author                          : heriksen
Create Date                     : 2014:08:13 15:58:32-06:00
Modify Date                     : 2014:08:14 11:48:31-06:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:c823f446-dd2a-4fc4-812d-1a01cb3475fd
Original Document ID            : adobe:docid:indd:dea6b38b-55dd-11de-b5b7-9e089606016f
Document ID                     : xmp.id:9CE93BDF3423E4118268CAF263EC1B48
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:9BE93BDF3423E4118268CAF263EC1B48
Derived From Document ID        : xmp.did:30025FF46CC9E311AADAAB3DA36156EA
Derived From Original Document ID: adobe:docid:indd:dea6b38b-55dd-11de-b5b7-9e089606016f
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:08:13 15:58:32-06:00
Metadata Date                   : 2014:08:14 11:48:31-06:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Title                           : iCLASS SE U90 Reader Installation Guide
Creator                         : heriksen
Rights                          : © 2009 HID Global Corporation.  All rights reserved.
Marked                          : True
Web Statement                   : www.hidglobal.com
Startup Profile                 : Print
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JQ6-ICLASSU90

Navigation menu