                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 1 -    OPERATING MANUAL    MOTOROLA SDC1000
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 2 -          CONTENTS    1. Important Safety Instructions   2. General   3. Features    4. Specifications   5. Name of the Parts    6. Identifying supplied parts    7. Installation of the Product    8. Wire Color Table of the Main Unit    9. Wire Connection in of basic application   10. Initial Setup    11. Operation   12. Setting Changes    13. FCC REGISTRATION INFORMATION   14. Warranty and Service
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 3 - 1. Important Safety Instructions  When using your door access controller, basing safety precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons including following: 1. Read and understand all instructions.  2. Follow all warnings and instructions marked on the product 3. Do not use liquid cleaners, or aerosol cleaners. Use a damp cloth for cleaning. if necessary, use a mild soap. 4. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool. 5. This product should be operated only from the type of power source indicated on the marking label. if you are not sure of the type of power supply to your home, consult your dealer or local power company. 6. Never push objects of any kind into this product though the cabinet slots as they may touch voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product. 7. To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. incorrect reassembly can cause electric shock when the appliance is subsequently used. 8. Unplug this product from the wall outlet and refer to qualified service personnel under the  following conditions:   a. When the power supply cord or plug is damaged or frayed.   b. If liquid has been spilled into the product   c. If the product has exposed to rain or water.   d. If the product doses not operate normally by following the operating instructions.     Adjust only those controls, that are covered by the operating instructions. Improper     adjustment of other controls in damage and will often require extensive work by  a qualified      technician to restore the to normal operation. e. If the product exhibit a distinct change in performance.  2. General  SDC1000 is an intelligent one door Access Controller based on powerful 8 bit Microprocessor to meet a simple and cost-effective access control market requirement. User friendly device allows you to register max. 128 USER IDs and easy to add or delete USER RFIDs. There are 5 inputs to connect EXIT Button, door contact, PIR sensor , Fire sensor and extra and you can program related output sources and activate timing from the front keypads. System will make alarm in case of number of times wrong entry and Temper switch opens and one TTL output can be connected to Auto-dialer (option) will make a call to the pre-defined phone numbers (max 4ch) and report the alarm to Police, Fire station and/or to your cellular phone by voice message. All event transaction report to the computer by RS232C communication. The modern design and easy installation will provide you an accurate access control for single door and 3 LED indicators informs you all system operating at real time. SDC1000 will give you field proven reliability and cost-effective solution anywhere the access controls and high security is required.        3. Features  - One door Access Controller - Powerful dual 8 bit Microprocessors - Built-in 4” Proximity Reader - 128 USER Access RFIDs including one Master RFID - Independant  5 inputs and 4 outputs including 2 output Relays - All I/Os and activating Times user front programmable - Door Lock and Unlock function  - Setting for Safe/Secure mode  - Numbers of Try-out error Alarm  - RS232 communication port for remote control and events report - 3 LEDs for system operation status  - Modern design and easy operation
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 4 - 4. Specification   .CPU   : Dual 8 bit Microprocessors  .Memory   : 8 KB Program memory      512 bytes Flash memory  .User PIN numbers  : 128 User RFIDs including one Master RFID  .Proximity Reader  : Built-in 4” Proximity reader  .Input/Output  : 5 Inputs max. rating at DC 12V/20mA : 2 Relay outputs : DC12V/2A : 1 chime bell output : 5V/150mA , : 1 TTL output : 5V/20mA   .Communication  : One RS232C port, 9600 Baud Rate,N,8,1  .Keypads   : 12 Numeric Keypads  .LED   : 3 LEDs(RED, GREEN, YELLOW)  .Power   : DC 12V/ 200mA  .Operating Environment : 0°C  to +60°C, 10% to 90% Humidity  .Reset   : Power ON Reset   5. Name of each part      SDC1000      Main Unit        6. Identifying supplied parts Please unpack and check the contents of the box.               Main Unit   Wall Mount   O-Ring Instructions     (1 EA)      (1 EA)     (5 EA)      (1 EA)
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 5 - 7. Installation of the Product  7-1. Drill two 6-32 holes and one 1/2" hole on the proper location of the wall.  (If the gang box is already installed on the wall then skip this step.)  7-2. Using 2 screws, install wall mount to the wall.  7-3. Insert 5 O-rings to the wall mount as indicated, then route the cable of the main       unit through the center hole and push the main unit to wall mount to lock the main      unit and make sure that the main unit is locked with wall mount.                     * CAUTIONS * When the main unit is once fixed to wall mount, the locking pins will tighten the main unit therefore the operation test of the main unit should be required prior to fix the main unit to wall mount. If the main unit has to be disassembled from the wall mount, then you need another wall mount to be replaced as the locking pins of wall mount will be broken when the main unit detached from the wall mount.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 6 - 8. Wire Color Table of the Main Unit  POWER Power(DC 12V)   +12V   Red wire, Red with White stripe Power(DC 12V)   0V(GND)  Black wire, Black with White stripe  OUTPUT Door RELAY(2A)  COM   Gray wire with Red stripe Door RELAY(2A)  NC   Blue wire with White stripe Door RELAY(2A)  NO   White wire with Red stripe  Alarm RELAY(2A)  COM   White wire Alarm RELAY(2A)  NC   Purple wire with White stripe Alarm RELAY(2A)  NO   Purple wire  TTL Output   TTL   Orange wire with White stripe CHIME BELL Output  BELL   Brown wire with White stripe  INPUT Exit Button   EXIT   Yellow wire with Red stripe Door Sensor   CONTACT  Green wire External Input #1  IN#1   Orange wire  External Input #2  IN#2   Green wire with White stripe External Input #3  IN#3   Brown wire Extra Reader Input  DATA0   Pink wire Extra Reader Input  DATA1   Cyan wire  RS232C INTERFACE RS232-TX   TXD   Grey wire RS232-RX   RXD   Blue wire RS232-GND   GND   Yellow wire
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 7 -  9. Wire connection for basic application This connection can be changed for different applications.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 8 -  9-1. Power Connection      Connect (+)wire of DC 12V power to Red wire and Red/White stripe wire and      connect Power GND(-)wire of DC 12V to Black wire and Black/White stripe wire.   9-2. Door Lock connection   9-2-1 Connection of POWER FAIL SAFE: Door Lock        - Connect Door RELAY(COM),Grey/Red stripe wire to DC +12V.        - Connect (+)wire of Door Lock to Door RELAY(NC),Blue/White stripe wire.        - Connect (-)wire of Door Lock to Power GND(-) wire.   9-2-2 Connection of POWER FAIL SECURE Door Lock        - Connect Door RELAY(COM),Grey/Red stripe wire to DC +12V.        - Connect (+)wire of Door Lock to Door RELAY(NO),White/Red stripe wire.        - Connect (-)wire of Door Lock to Power GND(-) wire.    9-3. Alarm Device connection    - Connect Alarm RELAY(COM),white wire to DC +12V.    - Connect (+)wire of Alarm Device to Alarm RELAY(NO),Purple wire.    - Connect (-)wire of Alarm Device to Power GND(-) wire.   9-4. Exit Button connection    - Connect one of the wire of Exit Button to Exit Button Input, Yellow/Red stripe wire.    - Connect the other wire of Exit Button to Power GND(-) wire.      (In case of using Normal Closing Contact for Exit Button then please make setting         change of ACTIVE level of Exit Button in section 8-20)   9-5. Door Contact sensor connection    - Connect Door Contact sensor(COM) wire to Door Contact Input, Green wire.    - Connect Door Contact sensor(NO) wire to Power GND(-) wire.      (In case of using Normal Closing(NC) Contact for Door Contact sensor then        please make setting change of ACTIVE level of Door Contact in section 8-21)    9-6. Auxiliary Input Device connection(Applied to AUX Input#1,#2,#3)    - Connect one wire of Auxiliary Input Device to AUX Input wire      (Input#1 Orange, Input#2 Green/White stripe, Input#3 Brown wire).    - Connect the other wire of Auxiliary Input Device to Power GND(-) wire.      (In case of using Normal Closing(NC) Contact for Auxiliary Input Device then        please make setting change of ACTIVE level of AUX Input in section 8-17 ~ 8-19)
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 9 -  9-7. Auto-dialer connection(Extra Purchase, If Necessary)    - Connect the input wire of Auto-dialer to TTL output, Orange/White stripe wire.    - Connect (+)wire of Auto-dialer to DC +12V.    - Connect (-)wire of Auto-dialer to Power GND(-) wire.    - Connect Telephone Line plug(RJ-14) to Auto-dialer.      (In case of using Low ACTIVE for Auto-dialer then        please make setting change of ACTIVE level of TTL Output in section 8-22)   9-8. RS232C Communication port Connection    9-pin connector(COM Port, female) is required to connect Serial communication    (RS232C) between Main Unit to Personal Computer.     Purchase 9-pin Female Connector, then connect wires as follow.    - Connect RS232-TX, Grey wire of Main Unit to pin number 2 of 9-pin connector.    - Connect RS232-RX, Blue wire of Main Unit to pin number 3 of 9-pin connector.    - Connect RS232-GND, Yellow wire of Main Unit to pin number 5 of 9-pin connector.    - Plug in 9-pin connector to COM1 or COM2 Port of Personal Computer.    - Install and run SDC1000 Time & Attendance Software.   9-9. Chime Bell Unit connection(Extra Purchase, If Necessary)    - Connect Red(+) wire of Chime Bell Unit to Bell Output, Brown/White wire of Main Unit.     - Connect Black(-) wire of Chime Bell Unit to Power GND(-) wire.  9-10. Extra Proximity Reader connection(Extra Purchase, If Necessary)  - Connect (+)wire of Reader to DC +12V.    - Connect (-)wire of Reader to Power GND(-) wire. - Connect Wiegand output DATA0 of Reader to Pink wire - Connect Wiegand output DATA1 of Reader to Cyan wire.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 10 - 10. Initial Setup Main Unit has Flash Memory to retain all setting values and when it delivered to customer there is no data in the memory therefore Initial Setup is required for the first use.  10-1. Registration of RF Cards for RF CARD ONLY MODE  * This mode is only applicable when the extra proximity reader is connected.    ¨ç Turn switch on DC12V Power Supply.       All 3 LEDs will be flashing with starting sound.    ¨è Press 0 1 ENT from the keypad.(RF CARD ONLY MODE )        ¨é Present RF Cards as follow to register Master Card and User Access Cards.                                                    ........       Master Card       User Access Cards            Master Card(Finish setup)     ¨ê First read card is registered as Master Card and the RF Cards followed to Master        Card are registered as User Access Cards then present Master Card again to finish        setup. (Please keep Master Card at the secure location for further setting changes.)    ¨ë Now, the Main Unit is entered to normal operation mode with default setting.   10-2. Registration of RF Cards with PIN for RF CARD + PIN MODE   * This mode is only applicable when the extra proximity reader is connected.   ¨ç Turn switch on DC12V Power Supply.       All 3 LEDs will be flashing with starting sound.    ¨è Press 0 2 ENT from the keypad.(RF CARD + PIN MODE )    ¨é Present RF Cards as follow to register Master Card and User Access Cards and type           4~6 digits Personal Identification Number(PIN) followed by each User Access Card.                                                    ........       Master Card    User Access Cards+PINENT      Master Card(Finish setup)     ¨ê First read card is registered as Master Card and the RF Cards+PINENT followed        to Master Card are registered as User Access Cards with PIN numbers then present       Master Card again to finish setup.       (Please keep Master Card at the secure location for further setting changes.)
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 11 -    ¨ë Now, the Main Unit is entered to normal operation mode with default setting.   10-3. Registration of PIN ONLY MODE    ¨ç Turn switch on DC12V Power Supply.       All 3 LEDs will be flashing with starting sound.    ¨è Press 0 3 ENT from the keypad.(PIN ONLY MODE )    ¨é Enter a 8 digits PIN number + ENT to register Master PIN number then type 4~6       digits PIN number + ENT to register User Access PIN numbers then type 8 digits       Master PIN number to finish setup.        8digits PINENT     4~6digits PINENT  ...       8digits Master PINENT         Master PIN       User Access PIN   ...        Master PIN(Finish setup)     ¨ê First 8 digits PIN number is registered as Master PIN and 4~6 digits PIN followed        to Master PIN are registered as User Access PIN numbers then type Master PIN       again to finish setup.       (Please write and remember Master PIN number for further setting changes.)    ¨ë Now, the Main Unit is entered to normal operation mode with default setting.   10-4. Default Setting Values  After the Initial Setup, the Main Unit stores its default setting values as follows and run  normal operation mode. If you want to change the setting values, add or delete USER  Access Cards(or PIN) then please refer to "Setting Changes" in section 8.      ¨ç When User Access Card(or PIN) is granted     - Door RELAY activates for 3sec.      - Green LED lights on for 3sec.       ¨è When User Access Card(or PIN) is denied     - Alarm RELAY activates for 2sec.     - Red LED lights on for 2sec.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 12 - 11. Operation    11-1. Normal Operation Mode(Safe Mode)                 When the Main Unit is running in normal operation mode,                 Yellow LED is flashing every second.      11-2. Open the Door                        User Access Card(or PIN) is granted, Door opens for 3 seconds                                                   with "do-mi-sol-do" melody.       Registered card(or PIN)     11-3. Exit(Open the Door)                   To exit, press Exit Button and Door opens for 3 seconds.        11-4. Alarm by Unregistered Card(or PIN)      User Access Card(or PIN) is not registered and access is denied,        then Alarm RELAY activates for 2 sec. with "sol-do-sol-do" melody.          Unregistered card(or PIN)      (If you do not want to activate Alarm, then please change settings in section 8-22.)   11-5. Secure Mode      Last exit person can change the mode from Safe Mode to Secure Mode by pressing.  Secure Code from the keypad so that the Alarm will generate by AUX Inputs.                          -> Change to Secure Mode.        It will canceled automatically when the registered card(or PIN) is present.  11-6. DURESS Alarm      In case of opening the door by Duress condition, press Duress PassWordENT and      open the door as usual then Duress Alarm(TTL Output) will activate.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 13 - 11-7. Chime Bell operation      When the guest presses ESC(Bell) Button from the keypad, Chime Bell melody is      activating for 5 seconds.  12. Setting Changes   To change previous setting values, you need Master Card(or PIN) to get in to Setting Change mode. First present Master Card(or press Master PIN) and enter 2-digit command code.                  Present Master Card(or PIN) and press 2digit command code.                      + Command code +               Command Change setting values  11  Add User Access Cards(RF CARD ONLY MODE)   12 Add User Access Cards and PIN(RF CARD + PIN MODE)  13 Add User Access PIN numbers(PIN ONLY MODE)  14  Delete User Access Cards(or PIN)  21  Change Door open time when User Access Card(or PIN) is granted  22  Change Alarm time when User Access Card(or PIN) is denied  23  Change Alarm time when Try Our error detected  24  Change Alarm time when Door Contact error detected  25  Change Alarm time when AUX#1 Input detected  26  Change Alarm time when AUX#2 Input detected  27  Change Alarm time when AUX#3 Input detected  28  Change Alarm time when magnet detected  29  Register 2 digits Duress Alarm Code  30  Change Alarm time when Duress Alarm detected  31  Test Door open time set by command "21"  32  Test Alarm time set by command "22"  33  Test Alarm time set by command "23"  34  Test Alarm time set by command "24"  35  Test Alarm time set by command "25"   36  Test Alarm time set by command "26"   37  Test Alarm time set by command "27"  39  Change Chime Bell activating time
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 14 -    Command Change setting values  41  Unconditional Door Open   42  Unconditional Door Close  43  Enable QUICK ACCESS MODE(Operate only PIN MODE)  44  Disable QUICK ACCESS MODE(Operate only PIN MODE)  51 Disable Melody sound  52 Enable Melody sound  60 Change keypad lock time when Try Out error detected  61 Detect AUX#1 Input from 'L' to ‘H'   62 Detect AUX#1 Input from 'H' to ‘L'  63 Detect AUX#2 Input from 'L' to ‘H'   64 Detect AUX#2 Input from 'H' to ‘L'  65 Detect AUX#3 Input from 'L' to ‘H'   66 Detect AUX#3 Input from 'H' to ‘L'   67 Detect Exit Button Input from 'L' to 'H'  68 Detect Exit Button Input from 'H' to 'L'   69 Detect Door Contact sensor Input from 'L' to 'H'   70 Detect Door Contact sensor Input from 'H' to 'L'  71 Activate TTL output to ‘H'  72 Activate TTL output to ‘L'  77 Enable Chime Bell Output  78 Disable Chime Bell Output  80 Set delay time to activate SECURE MODE  81 Set watch-dog time for Door Contact sensor  82 Set number of times of Try-Out  83 Set input limit time from the keypad   84 Set Temper Alarm port    88 Enable Temper Alarm  89 Disable temper Alarm  99 Initialize and erase all setup data
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 15 -  12-11. Add User Access Cards(RF CARD ONLY MODE)                              11ENT                    .....       Master card      Command      Cards to be registered ....       Master card       12-12. Add User Access Cards(RF CARD + PIN MODE)                        12ENT             PINENT  .....       Master card      Command      Cards to be registered ....       Master card   12-13. Add User Access PIN(PIN ONLY MODE)     MasterPINENT    13ENT       PINENT  .....         MasterPINENT      Master PIN       Command   PIN to be registered ....        Master PIN     12-14.1. Delete User Access Cards(RF CARD ONLY MODE, RF CARD+PIN MODE)                        14ENT     CardNumberENT  .....        Master Card      Command     Cards to be deleted ....          Master Card   12-14.2. Delete User Access PIN(PIN ONLY MODE)     MasterPINENT    14ENT      PINENT  .....         MasterPINENT      Master PIN       Command    PIN to be deleted ....        Master PIN
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 16 -   <Table 1> Settings for command 21~28                      Symbol  Setting Values     Examples/Remarks  Output  Mode   OM (You must add value ¨ç and ¨è)  Setting value for activating time ¨ç Activate Time   Value    Activate only Secure Mode : 00    Activate all the time : 50 ____________________________________________ Setting Value for activate Output Port ¨è Activate Output Port Value    Activate only Door Relay  : 01    Activate only Alarm Relay  : 02 Activate only TTL Output  : 04 Activate Door Relay & TTL          : 05 Activate Alarm Relay & TTL   : 06 EX1)Activate Door Relay     all the time     Door RELAY 01     All the time 50       OM = 51  EX2)Activate Alarm Relay     and TTL during the     Secure mode     Alarm+TTL  06     Secure Mode 00       OM = 06    tt  tt is the activating time value(seconds)  from 01sec. to 99sec.  tt value 00sec. means  no operation.    PW  PW is the 2 digits PassWord for   Duress Alarm.  Do not use ‘77’ as it Is  used for Secure Mode    mm  mm is activating time value(minutes)  from 01min. to 99min.  mm value 00min. means  no operation.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 17 -    12-21. Change Door open time when User Access Card(or PIN) is granted        (Please refer to Table 1 for tt)      21ENT       ttENT       ttENT     Master card or      Command      Door time     TTL time    MasterPINENT    12-22. Change Alarm time when User Access Card(or PIN) is denied    (Please refer to Table 1 for OM, tt)      22ENT      OMENT    ttENT      ttENT       ttENT     Master card or      Command     Output Mode   Door time   Alarm Time    TTL time    MasterPINENT     12-23. Change Alarm time when Try Our error detected    (Please refer to Table 1 for OM, tt)      23ENT      OMENT    ttENT      ttENT       ttENT     Master card or       Command    Output Mode   Door Time   Alarm Time    TTL Time     MasterPINENT     12-24. Change Alarm time when Door Contact error detected    (Please refer to Table 1 for OM, tt)      24ENT      OMENT    ttENT      ttENT       ttENT     Master card or       Command    Output Mode   Door Time   Alarm Time    TTL Time     MasterPINENT   12-25. Change Alarm time when AUX#1 Input detected  12-26. Change Alarm time when AUX#2 Input detected    12-27. Change Alarm time when AUX#3 Input detected    (Please refer to Table 1 for OM, tt)     25ENT     26ENT      OMENT    ttENT      ttENT       ttENT     27ENT     Master card or       Command    Output Mode   Door Time   Alarm Time    TTL Time     MasterPINENT
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 18 -    12-28. Change Alarm time when magnet detected    (Please refer to Table 1 for OM, tt)      28ENT      OMENT    ttENT      ttENT       ttENT     Master card or       Command    Output Mode   Door Time   Alarm Time    TTL Time     MasterPINENT     12-29. Register 2 digits Duress Alarm PassWord    (Please refer to Table 1 for PW)       29ENT      PW     Master card or       Command    PassWord     MasterPINENT     * ‘00’ is registered as default PassWord.      12-30. Change Alarm time when Duress Alarm detected    (Please refer to Table 1 for OM, tt)      30ENT      OMENT    ttENT      ttENT       ttENT     Master card or       Command    Output Mode   Door Time   Alarm Time    TTL Time     MasterPINENT   12-31. Test Door open time set by command "21"  12-32. Test Alarm time set by command "22"  12-33. Test Alarm time set by command "23"  12-34. Test Alarm time set by command "24"  12-35. Test Alarm time set by command "25"  12-36. Test Alarm time set by command "26"    12-37. Test Alarm time set by command "27"       Outputs set by command will be tested.        31~37ENT     Master card or         Command     MasterPINENT
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 19 -    12-39. Change Chime Bell activating time    (Please refer to Table 1 for tt)      39ENT       ttENT     Master card or       Command    Chime Bell Time     MasterPINENT   12-41. Unconditional Door Open     Master card or       41ENT     MasterPINENT   12-42. Unconditional Door Close     Master card or       42ENT     MasterPINENT   12-43. Enable QUICK ACCESS MODE     When QUICK ACCESS MODE is enabled in PIN ONLY MODE,      Door will open just press ENT key.      Master card or       43ENT     MasterPINENT   12-44. Disable QUICK ACCESS MODE      Master card or       44ENT     MasterPINENT   12-51. Disable Melody sound     Master card or       51ENT     MasterPINENT   12-52. Enable Melody sound     Master card or       52ENT     MasterPINENT     12-60. Change keypad lock time when Try Out error detected    (Please refer to Table 1 for tt)      60ENT       ttENT     Master card or       Command    Keypad Lock Time     MasterPINENT
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 20 -  12-61. Detect AUX#1 Input from 'L' to ‘H'     AUX#1 input is detected on the raising edge of AUX#1 input      Master card or       61ENT     MasterPINENT   12-62. Detect AUX#1 Input from 'H' to ‘L'     AUX#1 input is detected on the falling edge of AUX#1 input      Master card or       62ENT     MasterPINENT   12-63. Detect AUX#2 Input from 'L' to ‘H'     AUX#2 input is detected on the raising edge of AUX#2 input      Master card or       63ENT     MasterPINENT   12-64. Detect AUX#2 Input from 'H' to ‘L'     AUX#2 input is detected on the falling edge of AUX#2 input      Master card or       64ENT     MasterPINENT   12-65. Detect AUX#3 Input from 'L' to ‘H'      AUX#3 input is detected on the raising edge of AUX#3 input      Master card or       65ENT     MasterPINENT   12-66. Detect AUX#3 Input from 'H' to ‘L'      AUX#3 input is detected on the falling edge of AUX#3 input      Master card or       66ENT     MasterPINENT   12-67. Detect Exit Button Input from 'L' to 'H'     Exit Button input is detected on the raising edge of Exit Button input      Master card or       67ENT     MasterPINENT   12-68. Detect Exit Button Input from 'H' to 'L'      Exit Button input is detected on the falling edge of Exit Button input      Master card or       68ENT     MasterPINENT   12-69. Detect Door Contact sensor Input from 'L' to 'H'      Door Contact input is detected on the raising edge of Door Contact input      Master card or       69ENT     MasterPINENT
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 21 -  12-70. Detect Door Contact sensor Input from 'H' to 'L'     Door Contact input is detected on the falling edge of Door Contact input      Master card or       70ENT     MasterPINENT   12-71. Activate TTL output to ‘H'     TTL output changes the state from logic '0' to logic '1' when it activates.      Master card or       71ENT     MasterPINENT   12-72. Activate TTL output to ‘L'     TTL output changes the state from logic '1' to logic '0' when it activates.      Master card or       72ENT     MasterPINENT   12-77. Enable Chime Bell Output     Master card or       77ENT     MasterPINENT   12-78. Disable Chime Bell Output     Master card or       78ENT     MasterPINENT     12-80. Set delay time to activate SECURE MODE    (Please refer to Table 1 for mm)      80ENT      mmENT     Master card or       Command     Delay Time     MasterPINENT     12-81. Set watch-dog time for Door Contact sensor    (Please refer to Table 1 for tt)      81ENT       ttENT     Master card or       Command    Watch-dog Time     MasterPINENT
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 22 -    12-82. Set number of times of Try-Out     NN is the Try-out numbers from 00 to 99 times.      82ENT       NNENT     Master card or       Command    Try-out Numbers     MasterPINENT     12-83. Set input limit time from the keypad     (Please refer to Table 1 for tt from 10 ~ 99)      83ENT       ttENT     Master card or       Command    Input Limit Time     MasterPINENT     12-84. Set Temper Alarm port      (Please refer to Table 1 for OM)      84ENT       OMENT     Master card or       Command     Alarm Port     MasterPINENT   12-88. Enable Temper Alarm     Master card or       88ENT     MasterPINENT   12-89. Disable temper Alarm     Master card or       89ENT     MasterPINENT   12-99. Initialize and erase all setup data     Please use this command when you really want to erase all data and start    the unit from the begining.      Master card or       99ENT     MasterPINENT
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 23 - 13. FCC REGISTRATION INFORMATION  FCC REQUIREMENTS PART 15  Caution: Any changes or modifications in construction of this device which are not expressly approved by the responsible for compliance cold void the user's authority to operate the equipment.  NOTE: This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions; 1. This device may not cause harmful interface, and 2. This device must accept any interference received, including interference that may cause undesired    operation.  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
                      MOTOROLA SDC1000                           SINGLE DOOR ACCESS CONTROLLER - 24 - 14. Warranty and Service  The following warranty and service information applies only to the United States of America and Republic of Korea. For the information in other countries, please contact your local distributor. To obtain in or out of warranty service, please prepay shipment and return the unit to the appropriate facility listed below.  IN THE UNITED STATES  RF LOGICS Inc. Service Center 3026 Scott Blvd., SANTA CLARA, CA95054 USA Tel.: (408) 980-0001 Fax.: (408) 980-8060 E-mail: rflogics@rflogics.com Web-site: www.rflogics.com  OUTSIDE OF THE UNITED STATES  ID TECK CO., LTD. Service Center 5F Ace Techno Tower Bldg., 684-1 Deungchon-dong, Gangsuh-gu, SEOUL 157-030, KOREA Tel.: +82 (2) 659-0055 Fax.: +82 (2) 659-0086 E-mail: webmaster@idteck.com Web-site: www.idteck.com  Please use the original container, or pack the unit(s) in a sturdy carton with sufficient packing to prevent damage, include the following information: 1. A proof-of-purchase indicating model number and date of purchase. 2. Bill-to address 3. Ship-to address 4. Number and description of units shipped. 5. Name and telephone number of person to contact. 6. Reason for return and description of the problem.  NOTE: Damage occuring during shipment is deemed the responsibility of the carrier, and claims should be made directly to the carrier.

Navigation menu