Hangzhou Hikvision Digital Technology 19ABNG Network Security Control Panel User Manual
Hangzhou Hikvision Digital Technology Co., Ltd. Network Security Control Panel Users Manual
Users Manual
Control Panel User Manual Network Security Control Panel User Manual UD.6L0206D1097A01 Control Panel User Manual User Manual COPYRIGHT © 2015 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual. Control Panel User Manual About this Manual This Manual is applicable to Control Panel The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version in the company website (http://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals. Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the properties of their respective owners. Legal Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. 0201001050925 Control Panel User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the R&TTE Directive 1999/5/EC, the EMC Directive 2004/108/EC, the LVD Directive 2006/95/EC, the RoHS Directive 2011/65/EU. Control Panel User Manual 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut Control Panel User Manual fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss. The precaution measure is divided into ‘Warnings’ and ‘Cautions’: Warnings: Serious injury or death may be caused if any of these warnings are neglected. Cautions: Injury or equipment damage may be caused if any of these cautions are neglected. Warnings Follow these safeguards to prevent serious injury or death. Cautions Follow these precautions to prevent potential injury or material damage. Warnings: Please adopt the power adapter which can meet the safety extra low voltage (SELV) standard. The power consumption cannot be less than the required value. Do not connect several devices to one power adapter as an adapter overload may cause over-heating and can be a fire hazard. When the product is installed on a wall or ceiling, the device should be firmly fixed. To reduce the risk of fire or electrical shock, do not expose the indoor used product to rain or moisture. This installation should be made by a qualified service person and should conform to all the local codes. Please install blackouts equipment into the power supply circuit for convenient supply Control Panel User Manual interruption. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the product yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Please do not look directly into the laser light within 6 meters because laser is hazardous to humans. Control Panel User Manual Cautions: Make sure the power supply voltage is correct before using the product. Do not drop the product or subject it to physical shock. Do not install the product on vibratory surface or places. Do not expose it to high electromagnetic radiating environment. Do not aim the lens at the strong light such as sun or incandescent lamp. The strong light can cause fatal damage to the product. The sensor may be burned out by a laser beam, so when any laser equipment is being used, make sure that the surface of the sensor not be exposed to the laser beam. For working temperature, please refer to the specification manual for details. To avoid heat accumulation, good ventilation is required for a proper operating environment. While shipping, the product should be packed in its original packing. Please use the provided glove when open up the product cover. Do not touch the product cover with fingers directly, because the acidic sweat of the fingers may erode the surface coating of the product cover. Please use a soft and dry cloth when clean inside and outside surfaces of the product cover. Do not use alkaline detergents. Improper use or replacement of the battery may result in hazard of explosion. Please use the manufacturer recommended battery type. Content Chapter 1 Introduction _________________________________________ 11 1.1 Overview _____________________________________________________ 11 1.2 Features ______________________________________________________ 11 Chapter 2 Installation and Wiring ________________________________ 14 2.1 Main Board Overview ___________________________________________ 14 2.2 Device Wiring _________________________________________________ 15 2.2.1 2.2.2 2.2.3 2.2.4 Detector Wiring __________________________________________________ Alarm Output Wiring ______________________________________________ Keypad Wiring ___________________________________________________ Printer Wiring ____________________________________________________ 15 17 17 19 2.3 System Start-up ________________________________________________ 19 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 Chapter 3 Control Panel Start-up _____________________________________________ Alarm Keypad Start-up _____________________________________________ Keypad Address __________________________________________________ Factory Settings __________________________________________________ Activating the Control Panel ________________________________________ 19 20 24 24 25 Keypad Operation (Local Operation) ____________________ 31 3.1 Alarm Keypad Configuration ______________________________________ 31 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 3.1.10 3.1.11 3.1.12 3.1.13 3.1.14 3.1.15 3.1.16 3.1.17 3.1.18 3.1.19 3.1.20 3.1.21 3.1.22 Installer Password Settings _________________________________________ Operator Configuration ____________________________________________ Zone Parameters Configuration ______________________________________ Telco Line Communication Control ___________________________________ Dialing Account Configuration _______________________________________ Alarm Receiver Phone Number Settings _______________________________ Zone Associated Relay Configuration _________________________________ Relay Event Linkage Configuration ____________________________________ Relay Time Settings _______________________________________________ Siren Configuration ________________________________________________ Control Panel Time Settings _________________________________________ Control Panel IP Configuration _______________________________________ Local Port Number Configuration ____________________________________ Subnet Mask Configuration _________________________________________ Gateway Configuration_____________________________________________ GPRS Configuration _______________________________________________ SIM Card No. Configuration _________________________________________ Uploading Center IP Configuration ___________________________________ Center Port No. Configuration _______________________________________ Center Protocol and Account Configuration ____________________________ Printer Settings ___________________________________________________ Siren Linked Event Configuration _____________________________________ 31 31 32 35 36 36 37 38 39 40 40 40 41 41 42 42 43 43 44 44 45 48 Control Panel User Manual 3.1.23 3.1.24 3.1.25 3.1.26 3.1.27 3.1.28 3.1.29 3.1.30 3.1.31 3.1.32 Emergency Alarm Linkage Configuration_______________________________ Control Panel Tampering Alarm Configuration __________________________ Testing Report Configuration ________________________________________ Partition Configuration _____________________________________________ Public Partition Settings ____________________________________________ Fault Detection Configuration _______________________________________ Center Group Configuration _________________________________________ Whitelist Parameters Configuration __________________________________ Schedule Configuration ____________________________________________ Wireless User Permission Configuration _______________________________ 49 50 50 51 56 56 59 62 67 73 3.2 Keypad Alarm Operation Code ____________________________________ 74 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 3.2.10 3.2.11 3.2.12 3.2.13 3.2.14 3.2.15 3.2.16 3.2.17 3.2.18 3.2.19 3.2.20 3.2.21 3.2.22 3.2.23 3.2.24 3.2.25 3.2.26 3.2.27 3.2.28 Chapter 4 Device Initialization _______________________________________________ Control panel Arming and Disarm ____________________________________ Stay Arming _____________________________________________________ Zone Bypass/Recovery _____________________________________________ Group Bypass ____________________________________________________ Group Bypass Recovery ____________________________________________ Canceling Keypad Alarm____________________________________________ Alarm Output Operation ___________________________________________ Emergency Alarm _________________________________________________ System Status Query ______________________________________________ Control Panel and Wireless Device Connection _________________________ Deleting the Specified Connected Wireless Device ______________________ Deleting all the Connected Wireless Device ____________________________ Main Operator Password Changing ___________________________________ Control Programming Operation _____________________________________ Entering Partition _________________________________________________ Alarm Center Test _________________________________________________ Project Mode ____________________________________________________ Enabling/Disabling Key Tone ________________________________________ LCD Backlight Control ______________________________________________ LCD Backlight off__________________________________________________ Pacing __________________________________________________________ SMS Arming/Disarming ____________________________________________ Control Panel Soft Recovery _________________________________________ Current Fault Tone Disabling ________________________________________ Test Report Manually Relaying _______________________________________ Keypad Locking and Unlocking ______________________________________ Exiting the Operation ______________________________________________ 74 74 74 75 75 75 75 76 76 76 77 77 77 77 77 78 78 78 78 78 78 79 79 79 80 80 80 80 Accessing by Client Software ____________________________ 81 4.1 Installing the iVMS-4200 _________________________________________ 81 4.2 User Registration and Login ______________________________________ 85 4.3 Network Security Control Panel Settings ____________________________ 86 4.3.1 Add/Edit/Delete the Device _________________________________________ 86 Control Panel User Manual 4.4 Security Control Panel Remote Control _____________________________ 88 4.4.1 4.4.2 Partition Remote Control ___________________________________________ 89 Zone Remote Control ______________________________________________ 90 4.5 Remote Configuration ___________________________________________ 91 4.5.1 4.5.2 4.5.3 System Information Configuration ____________________________________ 92 Network Configuration _____________________________________________ 97 Alarm Configuration ______________________________________________ 105 4.6 Others ______________________________________________________ 117 4.6.1 4.6.2 Fault Handling___________________________________________________ 117 Printer Configuration _____________________________________________ 118 4.7 Operation ___________________________________________________ 119 4.8 Status _______________________________________________________ 120 Chapter 5 Trouble Shooting ____________________________________ 122 Appendix1:Specifications ______________________________________ 131 Appendix2:CID Report _________________________________________ 132 Appendix3:LED Keypad Prompt Sound ____________________________ 134 Appendix4:Conversion Table ____________________________________ 134 10 Control Panel User Manual Chapter 1 Introduction 1.1 Overview The DS-19A08/16-BN (G) is a control panel that supports 8 partitions. The panel uses embedded microcontroller technology for zone monitoring and system status detection. The alarm or status reports can be transmitted to the central alarm monitoring station through programming. Multiple alarm types and report transmission methods (telephone network, the Ethernet network, and the GPRS wireless network) are supported. A mobile client is attached for key fobs such as pushing alarm notifications or status reports and remote arming/disarming. The control panel is deployed mainly in the security systems of shopping malls, stores, residences, apartments, communities, and so on. 1.2 Features Hardwire Zones and Relay Outputs 8/16 hardwire zones Hardwire zones signal monitoring (tampering alarm, and so on) Local 4-ch of relay output (12-ch expandable) Up to 12 channel extension relay outputs Relay outputs triggered by alarm events or system events Partitioning 8 partitions, which can be controlled independently 1 common partition (No.1 partition), that can be programmed to be linked with any other two partitions 11 Control Panel User Manual Event Log 1 Contact ID report cache that can store up to 250 reports Up to 8,000 alarm event logs, 2,000 operation events logs, and 1,500 management event logs can be stored with time tags Event logs tracing over the LAN GPRS communication and Short Message Service (SMS) (only) ADEMCO Contact ID communication over the telephone network Communication over Ethernet and the GPRS wireless network HIK-SDK communication over the Ethernet network Report Strategy Up to 2 independent central stations over the telephone lines Up to 2 independent central stations over the Ethernet network Up to 2 independent central stations over the GPRS wireless network Up to 6 independent report channel groups consisted of one main channel and 3 backup channels each, that can transmit reports in parallel Each report channel can be configured to transmit reports to the central alarm monitoring station over the telephone, Ethernet or GPRS wireless network Report can be pushed to a mobile phone with the mobile client Report message can be transmitted to the mobile users with an associated telephone number (SIM card) 6 communication channels over the Ethernet network based on the HIK-SDK protocol Remote Control Up to 32 key fobs for radio transmitter operations Key fobs operations with mobile client Message control operations such as arming, disarming, and clearing the alarm, via short messages sent from the associated telephone number Peripherals Devices 1 half-duplex RS-485 device bus, which can interface with keypads and relay modules Up to addressable keypads 1 external audio output for alarm warning devices such as sirens, bells, or horns with 12V DC power supply User Management Users are consisted of an Installer, a Master User, 15 keypad operators, and 16 network operators Authority level management of users assigned different security codes Power Supply Management Power supply interface with battery sensing hardware to prevent deep discharging and charge management circuit hardware for the external backup battery Automatically switch between A.C. power and backup battery power 12 Control Panel User Manual 1 auxiliary power output rated maximum 12V DC, 750 mA Manual hardware reset to factory defaults Additional Features Tamper and movement protection function Scheduling operations such as arming, disarming, and output activating 13 Control Panel User Manual Chapter 2 Installation and Wiring 2.1 Main Board Overview Main Board Overview No. Description No. Description Fuse 10 Printer Wiring Interface Incoming Telco Line Interface 11 Alarm Input Interface Handset Interface 12 Wireless Network Module Indicator Power Adapter 13 SIM Card Slot Lead-acid Battery 14 Wired Network Module Indicators* Alarm Bell 15 GPRS Antenna Socket Auxiliary Power Interface 16 LAN Interface Keypad Connection Interface 17 Reset Button Alarm Output Interface 18 TAMPER Switches* 14 Control Panel User Manual Wireless Network Module Indicator The distribution of wireless network module indicators is shown below. Wired Network Module Indicator The distribution of wired network module indicator is shown below. TAMPER Switches TAMPER2 indicates the movement alarm switch. TAMPER1 indicates the tampering alarm switch. 2.2 Device Wiring 2.2.1 Detector Wiring The alarm input interfaces of the control panel are show as follows. 15 Control Panel User Manual The wiring of sensor is shown as follows. Alarm Host NO NC Peripheral Security Detector Alarm Host Peripheral Security Detector 2.2KΩ 2.2KΩ NO Detector NC Detector The Tamper-proof wiring is shown below. 2.2KΩ TAMPER NO NC 2.2KΩ ZONE GND DETECTOR The resistance of 2.2KΩ,3.3KΩ, 5.6KΩ, and 8.2KΩ are all supported for the control panel. Only 2.2KΩ resistance can be used for tamper-proof. For being compatible with the EOL, you should configure the EOL resistance value of the corresponded zone. 16 Control Panel User Manual 2.2.2 Alarm Output Wiring The alarm output interfaces of the control panel are show as follows. The wiring of alarm output is shown as follows: DC12V DC12V NO/NC Relay (30V/1A) NO/NC Breaker COM External Device Breaker COM External Device External DC Load External AC Load The DC current supplied by the control panel is used for external devices. The load current cannot be over 1A. 2.2.3 Keypad Wiring The keypad wiring is shown as follows. 17 Control Panel User Manual 18 Control Panel User Manual 2.2.4 Printer Wiring The printer wiring is shown below. 2.3 System Start-up For configuring the security control panel, you should restore the system of the control panel after start-up. 2.3.1 Control Panel Start-up The keypad registration will be completed in 10 seconds after the control panel being power on. The system then will complete the start-up and enter the properly status of working. 19 Control Panel User Manual 2.3.2 Alarm Keypad Start-up The LED keypad will make continuously prompt tones if the keypad does not receive the registration respond from the control panel in 20 seconds after it being power on. While the registration is succeeded, the working status indicator will turn green. LED Alarm Keypad LED Alarm Keypad Armed Indicator Working Status Indicator Status Partition Arming Red (Continuously Light) Partition Disarming Green (Continuously Light) In Programming Green (Flickering) Main Operator Password Editing Green (Flickering) Remote Control Connecting Green (Flickering) Pacing Mode Red (Continuously Light) LED Alarm Keypad Run Indicator Working Status Indicator Status Normal Green (Continuously Light) In Project Red (Continuously Light) System Fault Orange (Flickering) Main Operator Password Editing Green (Flickering) In Programming Green (Flickering) Unregistered Keypad Red (Flickering) LED Alarm Keypad Channel Indicator Working Status Indicator Status Normal Off Alarm Red (Flickering) Exception Red (Continuously Light) Bypass Green (Continuously Light) 20 Control Panel User Manual LED Alarm Keypad Channel Indicator Status in Project Mode No. Description No. Description Off-hook Send CID Report Dialing Receive Confirmation Sound Alarm Connecter Disconnection Control Panel On-hook Receive Hands-shake Sound Alarm Connecter On-hook LED Alarm Keypad Channel Indicator Status in Status Mode No. Description No. Description AC Power Outages RS485 Device Disconnection Low Battery for Accumulator Wired Network Exception Control Panel Tampering Alarm Enabled Wireless Network Exception Telephone Line Disconnection Reserved LCD Alarm Keypad The system status display demonstration indicates the keypad display interface of system status without any key pressing. Powering on Display Demonstration The display demonstration after powering on is shown below. HIKVISION System Status (normal) Display Demonstration The display demonstration of system status (working properly) is shown below. Global Keypad SYS1D SYS2R SYS3A SYS4R SYS5R SYS6R SYS7R SYS8R The system status description is shown below. System Status SYS1D SYS2R SYS3A SYS4R Description Partition1 Disarmed Partition2 Ready Partition3 Armed Partition4 Ready 21 Control Panel User Manual System Status SYS5R SYS6R SYS7R SYS8R Description Partition5 Ready Partition6 Ready Partition7 Ready Partition8 Ready Partition Keypad HIKVISION System Fault Keypad Standby Status Display Demonstration The standby status display demonstration is shown below. HIKVISION SYS1D SYS2R SYS3A SYS4R SYS5R SYS6R SYS7R SYS8R V1.2.1 build 131211 2014.04.18 19:24:26 The LCD keypad displays the version of the control panel and the time of operation. Global Keypad Programming Status Display Demonstration The programing status includes normal status and abnormal status. The demonstration is shown below. Normal Status Programming... Abnormal Status Zone/Module Exception Programming... System Status (abnormal) Display Demonstration Global Keypad SYS1D SYS2R SYS3A SYS4R SYS5R SYS6R SYS7R SYS8R Partition Keypad 22 Control Panel User Manual The system exception display of the partition keypad includes interfaces of alarm, fault and bypass. Zone Alarm Zone Alarm 001 002 003 004 005 006 Zone Offline Zone Offline 001 002 003 004 005 006 Zone Fault Zone Fault 001 002 003 004 005 006 Zone Bypass Zone Bypass 001 002 003 004 005 006 System Pacing Display Demonstration The system pacing display demonstration is shown below. Work Test 001 002 003 004 005 006 System Fault Display Demonstration The system fault display demonstration is shown below. AC Power Off; Low Battery Voltage; Display Demonstration in Project Mode The demonstration is shown below. Network1: Connecting… Network1: Connected Network1: Sending Report… Network1: Sending report succeeded. 23 Control Panel User Manual 2.3.3 Keypad Address An address is required for each alarm keypad in the system. These addresses cannot be repeated. Once exchanging the alarm keypad, the address of the new keypad must be the same as the replaced one. You should configure the address via DIP switch of the keypad before powering on the system. The address should be in the range of 0~31. DIP ON Add. DIP 1 2 3 4 3 4 3 4 DIP ON Add. DIP 1 2 3 4 3 4 ON ON DIP 1 2 ON DIP 1 2 DIP 1 2 3 4 3 4 3 4 3 4 ON DIP 1 2 12 16 ON DIP 1 2 3 4 DIP 1 2 ON DIP 20 3 4 ON DIP 1 2 24 3 4 1 2 DIP 3 4 ON DIP 1 2 3 4 28 DIP 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 ON DIP 3 4 1 2 3 4 3 4 3 4 3 4 1 2 3 4 3 4 3 4 Add. ON 1 2 DIP ON 1 2 DIP 10 ON DIP ON DIP 1 2 11 ON 13 1 2 DIP ON 17 1 2 DIP 14 18 ON DIP ON DIP 15 19 DIP 3 4 3 4 ON ON 1 2 DIP DIP 1 2 ON ON ON Add. DIP 1 2 ON ON DIP ON 21 1 2 DIP ON 25 1 2 DIP 22 26 ON DIP ON 1 2 DIP 23 27 DIP ON 29 1 2 DIP 30 ON 1 2 DIP 31 2.3.4 Factory Settings If powering on the system before zone connection, a 2.2k Ohm resistance is required for bridge connection between each zone. Password and Report Installer Password: 012345 Main User Password: 1234 Power Recovery Default Installer Password: No 24 Control Panel User Manual Arming/Disarming Report: Yes Control Panel Duress Report: N/A CID Report: Account#1#2: No Dialing Type: DTMF Key fobs Programming: No For Detailed CID code, Please refer to CID Report. Zone: Zone 1 to 8/16: Real-time zone Urgent Soft Zone: Buzzing prompt sound Test: Testing Report Interval:N/A Timing: Entering Duration: 10 sec Exiting Duration: 30 sec Belling Duration: 5 min Network Parameters: IP Address: 192.0.0.64 Port No.: 8000 2.3.5 Activating the Control Panel Purpose: You are required to activate the control panel first before you can use the control panel. Activation via SADP, and Activation via client software are supported. Activation via SADP Software SADP software is used for detecting the online device, activating the device, and resetting the password. Get the SADP software from the supplied disk or the official website, and install the SADP according to the prompts. Follow the steps to activate the control panel. Steps: 1. Run the SADP software to search the online devices. 2. Check the device status from the device list, and select an inactive device. 25 Control Panel User Manual 3. Create a password and input the password in the password field, and confirm the password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4. Click OK to save the password. You can check whether the activation is completed on the popup window. If activation failed, please make sure that the password meets the requirement and then try again. 5. Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of Enable DHCP. 26 Control Panel User Manual 6. Input the password and click the Save button to activate your IP address modification. Activation via Client Software The client software is versatile video management software for multiple kinds of devices. Get the client software from the supplied disk or the official website, and install the software according to the prompts. Follow the steps to activate the control panel. Steps: 1. Run the client software and the control panel of the software pops up, as shown in the figure below. 27 Control Panel User Manual 2. Click the Device Management icon to enter the Device Management interface, as shown in the figure below. Check the device status from the device list, and select an inactive device. 28 Control Panel User Manual 3. 4. Click the Activate button to pop up the Activation interface. Create a password and input the password in the password field, and confirm the password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 5. 6. Click OK button to start activation. Click the Modify Netinfo button to pop up the Network Parameter Modification interface, as shown in the figure below. 29 Control Panel User Manual 7. Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of Enable DHCP. Input the password to activate your IP address modification. 30 Control Panel User Manual Chapter 3 Keypad Operation (Local Operation) 3.1 Alarm Keypad Configuration You should access the programming mode (only installer can access the programming mode) before keypad configuration. The command is shown below: 012345 *0# {1} Installer password: 012345 {2} Command Key: *0 # The command for exiting programming mode is *#. 3.1.1 Installer Password Settings The password of installer is used for accessing programming and initializing mode. The command is shown below. 000 012345 # {1} Installer Password Programming Address: 000. {2} Installer Password: The default password is 012345. The length of the configured password should be 1~ 6 characte. {3} End the command. 3.1.2 Operator Configuration The programming command of operator configuration is shown below. 31 Control Panel User Manual 001 *2 1234 # {1} Operator Programming Address: 001~016. {2} User Permission: 12 permissions. For details, please refer to the following table. No. Permission No. Permission Arming No Arming Report Unavailable Bypass Arming/Disarming No Disarming Report Unavailable Bypass Arming/Disarming No Arming/Disarming Report, Unavailable Bypass Arming Arming Report Unavailable Bypass Disarming Disarming Report Unavailable Bypass Arming/ Disarming Arming/Disarming Report Unavailable Bypass Arming No Disarming Report Disarming No Arming/Disarming Report Arming/Disarming No Arming/Disarming Report Bypass *0 Arming Arming Report Bypass *1 Disarming Disarming Report Bypass *2 Arming/Disarming Arming/Disarming Report Bypass {3} Specified the username and password, the length of user name should be in the range of 2 to 5 characters. {4} End the command. The username and password cannot be empty. If the password is configured as 0, the user will be deleted. The password of 00, 000, 0000, or 00000 all signify of deleting the user. The default password of the main operator is 1234 with the permission of 2. The default permission of other operators is 6. 3.1.3 Zone Parameters Configuration The parameters of zone include zone response time, zone arming type, linked local alarm output, linked siren output. The detailed command is shown below. 32 Control Panel User Manual 201 2 5 0 1 0 1 0 0 1 1 1 # 4 5 8 9 10 11 12 13 {1} Zone Parameters Programming Address: 201~208/216 For 8-zone network security control panel , the zone parameters programming address is 201~208. For 16-zone network security control panel, the zone parameters programming address is 201~216. {2} Zone Response Time. The 4 kinds of zone response time is shown as follows. Command Command Description Command Command Description 10 ms 250 ms 500 ms 750 ms {3} Zone Arming Type Command Command Description Command Command Description None 24-hour voiced zone Delay Zone Internal Delay Zone Key Arming/Disarming Zone Real-time Zone Fire Zone 24-hour non-voiced Zone Stay Arming {4} Linked Relay (Reserved) {5} Liked Alarm Output. Command Command Description Command Command Description Non-linked Alarm Output Linked Alarm Output {6} Bypass Group Command Command Description Command Command Description Unsuport Support {7} Alarm Recovery Report. Command Command Description Command Command Description No Alarm Recovery Report Alarm Recovery Report 33 Control Panel User Manual {8} Zone Loop Type Command Command Description Zone Loop without Tampering Prevention Switch NC Type of Loop with Tampering Prevention Zone Loop NO Type of Loop with Tampering Prevention Zone Loop The fire alarm zone do not support the configuration of zone loop type, and can only be set as 0,or an error value will be returned. {9} Tampering Prevention Linked Relay Command Command Description Command Command Description Non-linked Local Alarm Output Linking Local 1 Alarm Output Linking Local 2 Alarm Output Linking Local 1/2Alarm Output Linking Local 3 Alarm Output Linking Local 1/3 Alarm Output Linking Local 2/3 Alarm Output Linking Local 1/2/3 Alarm Output Linking Local 4 Alarm Output Linking Local 1/4 Alarm Output *0 Linking Local 2/4 Alarm Output *1 Linking Local 1/2/4Alarm Output *2 Linking Local 3/4 Alarm Output *3 Linking Local 1/3/4 Alarm Output *4 Linking Local 2/3/4 Alarm Output *5 Linking Local 1/2/3/4 Alarm Output {10} Tampering Prevention Linked Siren Output Command Command Description Command Command Description No Linked Siren Output With Linked Siren Output {11} Tampering Alarm Recovery Report 34 Control Panel User Manual Command Command Description Command Command Description No Tampering Prevention Recovery Report With Tampering Prevention Recovery Report {12} End of line resistors Command Resistance Value Command Resistance Value 2.2KΩ 3.3KΩ 4.7KΩ 5.6KΩ 8.2KΩ The resistance of 2.2KΩ or 3.3KΩ supports tamper-proof and non-tamper-proof wiring. The resistance of 4.7KΩ only supports tamper-proof wiring. The resistance of 5.6KΩor 8.2KΩ only supports non-tamper-proof wiring. {13} End the command. 3.1.4 Telco Line Communication Control The communication control command is used for setting the phone connection mode of alarm center 1 and 2. The detailed command is shown below. 457 0 0 3 3 # {1} The Telco line communication control programming address: 457 {2} Dialing Mode of Telephone Center1 {3} Dialing Mode of Telephone Center2 Command Command Description Command Command Description DTMF- double tone& multi-frequency (5/sec) DTMF- double tone& multi-frequency (10/sec) {4} Dialing Times of Telephone Center1 {5} Dialing Times of Telephone Center2 35 Control Panel User Manual Command Command Description Command Command Description 9 Times 2 Times *0 10 Times 3 Times *1 11 Times 4 Times *2 12 Times 5 Times *3 13 Times 6 Times *4 14 Times 7 Times *5 15 Times 8 Times {6} End the command. 3.1.5 Dialing Account Configuration The control panel supports phone dialing to upload alarm information. The dialing account command is shown below. 458 0 0 0 0 # {1} Dialing Account Programming Address: 458~459 Command Command Description Command Command Description 458 Corresponding Alarm Center 1 Dialing Account 459 Corresponding Alarm Center 2 Dialing Account {2}~{5} Account No.. The value range of the account No. is 0~F. It is recommended that the dilaing account should be the same as the allocated account of the alarm connecter. {6} End the command. 3.1.6 Alarm Receiver Phone Number Settings The control panel supports two dialing accounts. The maximum length of dialing number of 36 Control Panel User Manual each account is 31 digits. The command is shown as follows. 460 E0 ∙∙∙∙∙∙0 # {1} Programming Address of Phone Number of Alarm Connecter: 460~463 Address Command Description Address 460 Alarm Center1 Phone Number Programming Address 462 461 Command Description Alarm Center2 Phone Number Programming Address 463 A telephone number is separated into two segments. The 460 and 461 group represents the dialing number which is connected with alarm center1. The 462 and 463 group represents the dialing number which is connected with alarm center2. {2} The dialing number is 16 digits. All the telephone number should be end with *4. The length of the each center number is 31 digits, and the entering format should be {No.} + {Dwell Time} + {ext.No.} The default center number is E0000000000000000000000000000000. {3} End the command. Example 1: If the tele-phone number is 0571-88075998, you can enter 460057188075998*4# with the keypad for completing the configuration. Example 2: If the telephone number is 17951-88075998, there are two steps to set the phone number via the keypad. Steps: 1. Enter 46017951FFF88075998# with the keypad. 2. Enter 461*4# to complete the settings. 3.1.7 Zone Associated Relay Configuration The detailed programming command is shown below. 467 000 0 00 # {1} Relay Configuration Programming Address: 467 37 Control Panel User Manual {2} Zone No. {3} Add/Delete Relay Command Command Description Command Command Description Delete Add {4} Relay No. {5} End the command. After successfully operating once, you can continuously do configuration with the command of {Project} + {Relay No.} + {#}. No more than 9 relays can be linked. 3.1.8 Relay Event Linkage Configuration For relay event linkage configuration, please refer to the command below. 468 000 0 00 00 # {1} The programming address of enabling relay event linkage is 468~469. Command Function Description Command Function Description 468 Enable Relay Event Linkage 469 Disable Relay Event Linkage {2} Relay No. {3} Add/ Delete Relay Command Function Description Command Function Description Delete Relay Add Relay {4} Selecting Device/ System Command Function Description Command Function Description 00 Device 01 System {5} Event No. The device event command is shown below. 38 Control Panel User Manual Command Command Description Command Command Description Command Command Description 00 None 01 AC Power Down 02 Low Battery 03 Telephone Line Disconnection 04 Wired Network Exception 05 No Network Exception The system event command is shown below. Command Command Description Command Command Description Command Command Description 01 Entering Delay 02 Exiting Delay 03 Arming 04 Disarming 05 Alarm 06 Alarm Clearing 07 Alarm Recovery {6} End the command. After successfully operating once, you can continuously do configuration with the command of {Project} + { Relay No.} + {System Command.} + {Event Command} + {#}. 3.1.9 Relay Time Settings For Relay output time settings, please refer to the command below. 470 000 00 00 # {1} {2} {3} {4} {5} Relay Time Programming Address: 470 Relay No. Duration: In minute Duration: In second End the command. The maximum duration of triggering is 99 minutes and 59 seconds. The default duration is 30 seconds. After operating once, you can continuously configure with the command of {Project} + 39 Control Panel User Manual {Relay No.} + {Duration} + {#} 3.1.10 Siren Configuration For siren configuration, please refer to the command below. 471 1 # {1} Siren Configuration Programming Address: 471 {2} Enable/Disable Siren Command Command Command Description Command Command Description Disable Enable {3} End the Command. 3.1.11 Control Panel Time Settings For control panel time settings, please refer to the command below. 472 0000 00 00 00 00 00 # {1} {2} {3} {4} {5} {6} {7} {8} Control Panel Time Settings Programming Address: 472 Year Month Day Hour Minute Second End the Command. 3.1.12 Control Panel IP Configuration For control panel IP configuration, please refer to the command below. 40 Control Panel User Manual 473 192 000 000 064 # {1} {2} {3} {4} {5} {6} Control Panel IP Configuration Programming Address: 473. Unit 1 Unit 2 Unit 3 Unit 4. End the command. The IP address programming includes 12 digits. The 1 to 12 place indicates the IP address of the control panel. Each unit of the IP address includes 3 digits. You should enter 0 if the entered address is less than 3 digits for each unit for complement. For example, you should enter 192 002 028 066 for validating the IP address of 192.2.28.66. 3.1.13 Local Port Number Configuration The programming command of local port number setting is shown below: 474 0 8 0 0 0 # 2 3 4 5 6 7 {1} The programming command address of local port number setting is: 474; {2} Port: Ten Thousands’ Digit {3} Port: Thousands’ Digit {4} Port: Hundreds’ Digit {5} Port: Tens’ Digit {6} Port: Units’ Digit {7} End the command. Corresponding port number must be 5 digits. When the place is not sufficient, fill it up with 0. For example: When the port number is 6000, the programming command is: 474 06000#. 3.1.14 Subnet Mask Configuration The programming command of control panel subnet mask setting is shown below: 41 Control Panel User Manual 475 255 255 255 000 # {1} {2} {3} {4} {5} {6} The programming command address of control panel subnet mask setting is: 475; The First Unit; The Second Unit; The Third Unit; The Fourth Unit; End the command. 3.1.15 Gateway Configuration The programming command of gateway settings is shown below: 476 000 000 000 000 # {1} {2} {3} {4} {5} {6} The programming command address of control panel gateway setting is: 476; The First Unit; The Second Unit; The Third Unit; The Fourth Unit; End the command. 3.1.16 GPRS Configuration The programming command of GPRS settings is shown below: 477 {1} The programming command address of GPRS setting are: 477 {2} Name of APN; Command Description Command Description CMNET UNINET {3} Time of detecting link; Command Time Command Time 10s 170s 30s 190s 50s *0 210s 42 Control Panel User Manual Command {4} End the command. Time 70s 90s 110s 130s 150s Command *1 *2 *3 *4 *5 Time 230s 250s 270s 290s 300s 3.1.17 SIM Card No. Configuration The programming command of SIM Card No. settings is shown below: 478 0 0 0 0 0 0 0 0 0 0 0 # 2 3 7 8 9 10 11 12 13 4 5 6 {1} The programming command address of SIM card No. settings is 478. {2}~{12} SIM card No. {13} End the command. 3.1.18 Uploading Center IP Configuration The programming command of uploading center IP setting is shown below: 485 000 000 000 000 # {1} The programming command address of uploading center IP setting are: 485,488,491,494; Command Description Command Description 485 Programming Address of Network Center 1 IP Settings 488 Programming Address of Network Center 2 IP Settings 491 Programming Address of GPRS Center 1 IP Settings 494 Programming Address of GPRS Center 2 IP Settings {2} The First unit; {3} The Second unit; {4} The Third unit; 43 Control Panel User Manual {5} The Fourth unit; {6} End the command. 3.1.19 Center Port No. Configuration The programming command of uploading center port setting is shown below: 486 00000 # {1} The programming command addresses of uploading center port setting are: 486, 489, 492, 495; Command Description Command Description 486 Programming Address of Network Center 1 Port Settings 489 Programming Address of Network Center 2 Port Settings 492 Programming Address of WIFI Center 1 Port Settings 495 Programming Address of WIFI Center 2 Port Settings {2} Port number; {3} End the command. 3.1.20 Center Protocol and Account Configuration The programming command of center protocol and account setting is shown below: 487 2 000000000 # {1} The programming command addresses of center protocol and account settings are: 487, 490, 493, 496; Command Description Command Description 487 Network Center 1 Protocol and Programming Address of Account Settings 490 Network Center 2 Protocol and Programming Address of Account Settings 493 GPRS Center 1 Protocol and Programming Address of Account Settings 496 GPRS Center 2 Protocol and Programming Address of Account Settings 44 Control Panel User Manual {2} Protocol Type: Command Description HIK {3} Account; {4} End the command. 3.1.21 Printer Settings Printer Parameters Settings The programming commands of printer parameters setting are as below: 499 0 0 0 # 2 3 4 5 {1} The programming command address of printer parameter setting is:499; {2} Enable/disable the printer; Command Description Command Description Disable the Printer Enable the Printer {3} Enable/disable the off-line detection of printer; Command Description Command Description Disable the Off-line Detection of Printer Enable the Off-line Detection of Printer {4} Whether to print the reporting time or not, known as the time of control panel when event/alarm occurs; Command Description Command Description Not print the reporting time Print the reporting time {5} End of the command. Alarm Message Settings The programming commands of print setting of alarm message are as below: 500 0 0 0 # 2 3 4 5 {1} The programming command address of alarm message printing is: 500. 45 Control Panel User Manual {2} Enable/disable the sensor alarm; Command Description Command Description Disable Sensor Alarm Enable Sensor Alarm {3} Enable/disable emergency alarm; Command Description Command Description Disable Emergency Alarm Enable Emergency Alarm {4} Enable/disable duress alarm; Command Description Command Description Disable Control Panel Duress Alarm Enable Duress Alarm {5} End the command. Device Information Settings The programming commands of print setting of device information are as below: 501 0 0 0 0 0 0 0 0 # 3 4 5 6 7 8 9 10 {1} The programming command address of device information printing is: 501. {2} AC Power Off; {3} The storage battery is under voltage; {4} The ADSL is off-line; {5} Test Report; {6} Tamper-proof of the Control Panel; {7} The 485 device is off-line; {8} Network error; {9} Wireless connection exception. It indicates disabled status when 2) ~9) are set to be 0, and indicates enabled status when 2) ~9) are set to be 1. Command Description Command Description Disabled Enabled {10}End of the command. Operation Programming Information Settings The programming commands of print setting of operation programming information 46 Control Panel User Manual are as below: 502 0 0 0 0 0 0 0 # 2 3 4 5 6 7 8 9 {1} The programming command address of print setting of operation programming information is: 502; {2} Arming; {3} Disarming; {4} Canceling the alarm; {5} Bypass; {6} Enter the programming; {7} Exit the programming; {8} Control Panel Restoring; It indicates disabled status when 2) ~8) are set to be 0, and indicates enabled status when 2) ~8) are set to be 1. Command Description Command Description Disabled Enabled {9} End the command. Restoring Information of Alarm and Bypass Settings The programming commands of print setting of restoring information of alarm and bypass are as below: 503 0 0 # 2 3 4 {1} The programming command address of print setting of restoring information of alarm and bypass is: 503; {2} Sensor Alarm Recovering; Command Description Command Description Disabled Enabled {3} Bypass Recovering; Command Description Command Description Disabled Enabled {4} End the command. 47 Control Panel User Manual Device Recovering Information Settings The programming commands of print setting of device recovering information are as below: 504 0 0 0 0 0 0 0 # 2 3 4 5 6 7 8 9 {1} The programming command address of print setting of device recovering information is: 504; {2} AC power on; {3} The storage battery is not under voltage; {4} The ADSL is on-line; {5} The tamper-proof of the control panel is recovered; {6} The 485 device is on-line; {7} The network error is recovered; {8} The wireless connection exception is recovered. It indicates disabled status when 2) ~8) are set to be 0, and indicates enabled status when 2) ~8) are set to be 1. Command Description Command Description Disabled Enabled {9} End of command. 3.1.22 Siren Linked Event Configuration 509 0 00 00 00 # {1} {2} The programming command address of siren linked event configuration is 509(default: null) Add/Delete Event Configuration Command Description Command Description Delete Event Add Event Command Description Command Description 00 Global Event 01 Partition Event {3} Event Type {4} Detailed Event Type The global event types are shown below. 48 Control Panel User Manual Command Description Command Description Command Description 00 Null 01 Control Panel Tampering Alarm 02 Global Keypad Emergency Alarm 03 Ac Disconnected 04 Low Battery Voltage 05 Telco Line Disconnected 06 Wired Network Exception 07 Wireless Network Exception 08 Keypad /485 Device Disconnected The partition event types are shown below. Command Description Command Description 00 Null 01 Emergency Alarm 02 Arming 03 Disarming {5} Partition No. (It is not necessary to enter the partition No. when configuring global event) Command Description Command Description Command Description 00 Global Partition 01 No.1 Partition 02 No.2 Partition 03 No.3 Partition 04 No.4 Partition 05 No.5 Partition 06 No.6 Partition 07 No.7 Partition 08 No.8 Partition {6} End the command. 3.1.23 Emergency Alarm Linkage Configuration The programming command of emergency alarm linkage settings is shown below: 510 00 0 # 3 4 {1} The programming command address of emergency alarm linkage setting is: 510; {2} Partition Number, 00 indicate the global keypad, 01~08 indicate partitions 49 Control Panel User Manual No.1~No.8; {3} Whether to link the siren or not; Command Description Command Description Not link the Siren Link the Siren {4} End the command. 3.1.24 Control Panel Tampering Alarm Configuration The programming command of control panel tampering alarm settings is shown below: 511 0 {1} The programming command address of control panel tampering alarm is: 511; {2} whether to link the siren or not; Command Description Command Description Not link the Siren Link the Siren {3} End the command. 3.1.25 Testing Report Configuration The testing report is used to validate the communication of control panel and alarm center. The detailed operation is show as follows. 513 0 1 5 # {1} The testing report programming address is 513. {2} Enable/Disable the Testing Report Command Command Description Command Command Description Disable Enable {3} Timer of the Testing Report. 50 Control Panel User Manual Command Command Description Command Command Description 1/4H 3H 1/2H 4H 1H 6H 2H 8H Command Command Description Command Command Description 10H *2 18H 12H *3 20H *0 14H *4 22H *1 16H *5 24H {4} Testing Report Sending Interval Command Command Description Command Command Description Command Command Description 1H 12H 3D 2H 24H 5D 4H 2D 7D {5} End the command. 3.1.26 Partition Configuration Partition Start-up Configuration The programming command of the partition start-up configuration is shown below. 531 1 1 # {1} {2} {3} The programming of partition start-up configuration is: 531~538. The configuration item of 1 indicates the start-up configuration of the partition. Enable/Disable the Partition. Command Command Description Command Command Description Disable Enable 51 Control Panel User Manual {4} End the command. Only the No.1 partition is enabled as the default settings. Partition Keypad User Configuration The programming command of keypad user configuration of the partition is shown as follows. 531 2 0 000 # {1} {2} {3} The programming command address of keypad user configuration is 531~538. The configuration item of 2 indicates the keypad user configuration. Add/Delete the user. Command Command Description Command Command Description Delete Add {4} {5} The user No. End the command Added Separately: for instance, to add an user with the No. of 160 to the No.8 partition, the command should be 538 2 1 160 # Added/Deleted Continually: only continuous adding or deleting operation is supported. After adding/deleting a user separately, enter the command [Project]+[User No.]+[#] to continually add/delete users. For instance, to add users with the No. of 2,3,and 5, the command should be 538 2 1 002 # Project # 003 # Project # 005 #. Added/Delete in Batch: the formate is 531 2 x xxx xxx #. Added with user No. interval: for instance, to add users with the No. between 100~149 to the No.3 partition, the command should be 533.2.1.100.149 #. Partition Zone Configuration The programming command of zone configuration of the partition is shown below. 52 Control Panel User Manual 531 3 0 000 # {1} {2} {3} The programming command addressof zone configuration is 531~538. The configuration item of 3 indicates zone configuration of the partition. Add/Delete Zone. Command Command Description Command Command Description Delete Add {4} {5} Zone No. End the command. There are three mode to add/delete zone for the partition, adding/deleting separately, Adding/ Deleting continually and adding/deleting in Batch, for details, refer to the Partition Keypad User Configuration. Partition Keypad Configuration The programming command of keypad configuration of the partition is shown as follows. 531 4 0 00 # {1} The programming command address of zone configuration is 531~538. {2} The configuration item of 4 indicates keypad configuration. Add/Delete KeypadCommand Command Description Command Command Description Delete Add {3} Keypad No. {4} End the command. There are three mode to add/delete zone for the partition, adding/deleting separately, Adding/ Deleting continually and adding/deleting in Batch, for details, refer to the Partition Keypad User Configuration. 53 Control Panel User Manual Partition Time and Control Panel Duress Report Configuration To configure the system time and duress report, please see the command below. 531 5 1 3 2 0 # {1} System Time and Duress Report Programming Address: 531 {2} Classification Option of System Time and Duress Report: 5 {3} Entering Delay Command Command Description Command Command Description Command Command Description 10sec 60sec *1 110sec 20sec 70sec *2 120sec 30sec 80sec *3 130sec 40sec 90sec *4 140sec 50sec *0 100sec *5 150sec {4} Exiting Delay Command Command Description Command Command Description Command Command Description 10sec 60sec *1 110sec 20sec 70sec *2 120sec 30sec 80sec *3 130sec 40sec 90sec *4 140sec 50sec *0 100sec *5 150sec {5} Siren Working Duration Command Command Description Command Command Description Command Command Description 2min 5min 10min 15min 30min {6} Enable/Disable Control Panel Duress Report Command Command Description Command Command Description Disable Enable {7} End the command. 54 Control Panel User Manual The 24-hour non-voiced zone does not support linked siren output. Partition Report and Arming Prompt Sound Configuration To configure the system report and arming prompt sound, please see the command below. 531 6 0 0 0 0 # {1} system report and arming prompt sound programming address: 531 {2} Classification Option of Report and Arming Prompt Sound: 6 {3} Arming/disarming Report Ending Prompt Sound {4} Manual Testing Report Sending Prompt Sound. {5} Prompting sound of arming succeeded. {6} Prompting sound of disarming succeeded {3}~{6} Command Command Description Command Command Description Disable Enable {7} End the command. Partition Key User Permission Configuration To configure the permission of key user, please see the command below. 531 7 1 1 1 1 # {1} System key user permission programming address: 531. {2} System key user classification option: 7 {3} Arming Permission {4} Disarming Permission {5} Arming Report Permission {6} Disarming Report Permission {3}~{6} Command Command Description Command Command Description Disable Enable {7} End the command. 55 Control Panel User Manual 3.1.27 Public Partition Settings The programming commands of public partition settings are as below: 563 0 0 0 # {1} The public partition settings address is 563. {2} Enable/Disable public partition. Command Command Description Command Command Description Disable Enable {3} Associated Partition No.1. {4} Associated Partition No.2. {5} End the command. 3.1.28 Fault Detection Configuration Control Panel System Fault Detection Configuration To configure control panel system fault detection, please see the command below. 564 1 1 1 1 1 1 1 1 # {1} {2} {3} {4} {5} {6} {7} {8} 10 Control panel system fault detection address: 564. Ac Power Down Low Battery Control Panel Tampering Alarm Phone Line Disconnection Main Keypad Disconnection Network Exception GPRS Network Exception Command Command Description Command Command Description Disable Enable {9} Expension Bus Exception 56 Control Panel User Manual {10} End the command. If the fault detection is disabled, the control panel will not detect or report this sort of fault. Keypad Fault Display Configuration To configure the system fault display, please refer to the command below. 565 1 1 1 1 1 1 1 1 # {1} {2} {3} {4} {5} {6} {7} {8} 10 Keypad fault display configuration programming address: 565 Ac Power Down Low Battery Control Panel Tampering Alarm Phone Line Disconnection Main Keypad Disconnection Network Exception GPRS Exception Command Command Description Command Command Description Disable Enable {9} Expension Bus Exception {10} End the command. After successfully operating once, you can continuously do configuration with the command of {Project} + {Partition No.} + {Configuration} + {#}. Keypad Fault Prompt Sound Configuration To configure the keypad fault prompt sound, please see the command below. 566 1 1 1 1 1 1 1 1 # {1} {2} {3} {4} {5} {6} 10 Keypad fault prompt sound configuration programming address: 566. Ac Power Down Low Battery Control Panel Tampering Alarm Phone Line Disconnection Main keypad Disconnection 57 Control Panel User Manual {7} Network Exception {8} GPRS Exception Command Command Description Command Command Description Disable Enable {9} Expension Bus Exception {10} End the command. After successfully operating once, you can continuously do configuration with the command of {Project} + {Partition No.} + {Configuration} + {#}. Partition Fault Display Configuration To configure the partition fault display, please see the command below. 567 01 01 1 1 1 1 1 1 1 1 # {1} {2} {3} {4} {5} {6} {7} {8} {9} {10} 9 10 11 12 Partition fault display configuration programming address: 567. The Tens’ Digit of the Partition No. The Units’ Digit of the Partition No. Ac Power Down Low Battery Control Panel Tampering Alarm Phone Line Disconnection Main keypad Disconnection Neywork Exception GPRS Exception Command Command Description Command Command Description Disable Enable {11} Expension Bus Exception {12} End the command. Partition Fault Prompt Sound Configuration To configure the partition fault prompt sound, please see the command below. 568 01 01 1 1 1 1 1 1 1 1 # 58 9 10 11 12 Control Panel User Manual {1} {2} {3} {4} {5} {6} {7} {8} {9} {10} Partition fault display configuration programming address: 568. The Tens’ Digit of the Partition No. The Units’ Digit of the Partition No. Ac Power Down Low Battery Control Panel Tampering Alarm Phone Line Disconnection Main keypad Disconnection Network Exception GPRS Exception Command Command Description Command Command Description Disable Enable {11} Expension Bus Exception {12} End the command. 3.1.29 Center Group Configuration Center Group Enabling Configuration To enable the center group, please see the command below. 611 0 {1} Center Group Enabling Programming Address: 611, 615, 619, 623, 627and 631. Command Command Description Command Command Description 611 Center Group 1 Enabling Programming Address 615 Center Group 2 Enabling Programming Address 619 Center Group 3 Enabling Programming Address 623 Center Group 4 Enabling Programming Address 627 Center Group 5 Enabling Programming Address 631 Center Group 6 Enabling Programming Address {2} Enable/Disable the Center Group 59 Control Panel User Manual Command Command Description Command Command Description Disable Enable {3} End the command. Center Group Uploading Mode Configuration To configure the center group uploading mode, please see the command below. 612 0 0 0 0 # {1} Center Group Uploading Mode Programming Address: 612, 616, 620, 624, 628 and 632. Command Command Description Command Command Description 612 Center Group1 Uploading Mode Programming Address 616 Center Group 2 Uploading Mode Programming Address 620 Center Group 3 Uploading Mode Programming Address 624 Center Group 4 Uploading Mode Programming Address 628 Center Group 5 Uploading Mode Programming Address 632 Center Group 6 Uploading Mode Programming Address {2} Main Channel {3} Backup Channel 1 {4} Backup Channel 2 {5} Backup Channel 3 {2}~{5}The channel can be selected as follows. Command Command Description Command Command Description OFF T1 T2 N1 N2 G1 G2 {6} End the command. 60 Control Panel User Manual There are 6 channels (T1, T2, N1, N2, G1 and G2) of the network security control panel. Each channel can be only used once during the center group uploading configuration, no matter it is served as the main channel or backup channel, Center Group Zone Alarm Report Configuration To configure the center group zone alarm report, please refer to the following command. 613 0 000 # {1} Center Group Zone Alarm Report Programming Address: 629 and 633. 613, 617, 621, 625, Command Command Description Command Command Description 613 Center Group 1 Zone Alarm Report Programming Address 617 Center Group 2 Zone Alarm Report Programming Address 621 Center Group 3 Zone Alarm Report Programming Address 625 Center Group 4 Zone Alarm Report Programming Address 629 Center Group 5 Zone Alarm Report Programming Address 633 Center Group 6 Zone Alarm Report Programming Address {2} Delete/Add {3} Zone No. {4} End the command. The operation of adding/ deleting is just for current center group sending/not sending report, and will not impact other center groups. Center Group Non-zone Alarm Report Configuration To configure the non-zone alarm report of the center group, please refer to the command below. 614 1 1 1 1 1 1 1 1 1 1 # 61 9 10 11 12 Control Panel User Manual {1} Center Group Non-zone Alarm Report Programming Address: 614, 618, 622, 626, 630and 634. Command Command Description Command Command Description 614 Center Group1 Non-zone Alarm Report Programming Address 618 Center Group 2Non-zone Alarm Report Programming Address 622 Center Group3 Non-zone Alarm Report Programming Address 626 Center Group 4 Non-zone Alarm Report Programming Address 630 Center Group 5 Non-zone Alarm Report Programming Address 634 Center Group 6 Non-zone Alarm Report Programming Address {2} Soft Zone Report {3} System Status Report {4} Alarm Clearing Report {5} Testing Report {6} Arming Report {7} Disarming Report {8} Control Panel Duress Reportage {9} Alarm Recovery Report {10} Bypass Report {11} Bypass Recovery Report {2}~{11}Set the value as 1 to send the report. Set the value as 0 not to send the report. Command Command Description Command Command Description Not Sending Sending {12} End the command. 3.1.30 Whitelist Parameters Configuration Non-zone Alarm Report Configuration To configure the non-zone alarm report, please refer to the command below. 680 00 0 0 0 0 0 0 0 0 0 0 0 # 3 4 5 6 7 8 9 10 11 12 13 14 {1} Non-zone Alarm Report Configuration Command Address: 680. 62 Control Panel User Manual {2} White List Number. 01~08 indicate white list No.1~No.8. {3} Enable/Disable the Non-zone Alarm Report Command Command Description Command Command Description Disable Enable {4} Soft Zone Report {5} System Status Report {6} Alarm Clearing Report {7} Testing Report {8} Arming Report {9} Disarming Report {10} Control Panel Duress Report {11} Alarm Recovery Report {12} Bypass Report {13} Bypass Recovery Report {4}~{13} Set the value as 1 to send the report. Set the value as 0 not to send the report. Command Command Description Command Command Description Not Sending Sending {14} End the command. Partition Arming Permission Configuration To configure the permission of partition arming, please refer to the command below. 681 00 0 0 0 0 0 0 0 0 # 3 4 5 8 9 10 11 {1} Partition Arming Permission Configuration Command Address: 681 {2} White List Number. 01~08 indicate white list No.1~No.8. {3} The Arming Permission of Partition 1 {4} The Arming Permission of Partition 2 {5} The Arming Permission of Partition 3 {6} The Arming Permission of Partition 4 {7} The Arming Permission of Partition 5 {8} The Arming Permission of Partition 6 {9} The Arming Permission of Partition 7 {10} The Arming Permission of Partition 8 {3}~{10} Enable/Disable the Permission of Partition Arming 63 Control Panel User Manual Command Command Description Command Command Description Disable Enable {11} End the command. Partition Disarming Permission Configuration To configure the permission of partition disarming, please refer to the command below. 682 00 0 0 0 0 0 0 0 0 # 3 4 5 8 9 10 11 {1} Partition Disarming Permission Configuration Command Address: 682 {2} White List Number. 01~08 indicate white list No.1~No.8. {3} The Disarming Permission of Partition 1 {4} The Disarming Permission of Partition 2 {5} The Disarming Permission of Partition 3 {6} The Disarming Permission of Partition 4 {7} The Disarming Permission of Partition 5 {8} The Disarming Permission of Partition 6 {9} The Disarming Permission of Partition 7 {10} The Disarming Permission of Partition 8 {3}~{10} Enable/Disable the Permission of Partition Disarming Command Command Description Command Command Description Disable Enable {11} Completing Partition Alarm Clearing Permission Configuration To configure the permission of partition alarm clearing, please refer to the command below. 683 00 0 0 0 0 0 0 0 0 # {1} {2} {3} {4} {5} 3 4 5 8 9 10 11 Partition Alarm Clearing Permission Configuration Command Address: 683 White List Number. 01~08 indicate white list No.1~No.8. The Alarm Clearing Permission of Partition 1 The Alarm Clearing Permission of Partition 2 The Alarm Clearing Permission of Partition 3 64 Control Panel User Manual {6} The Alarm Clearing Permission of Partition 4 {7} The Alarm Clearing Permission of Partition 5 {8} The Alarm Clearing Permission of Partition 6 {9} The Alarm Clearing Permission of Partition 7 {10} The Alarm Clearing Permission of Partition 8 {3}~{10} Enable/Disable the Permission of Partition Alarm Clearing Command Command Description Command Command Description Disable Enable {11} End the command. The Interval Time of Whitelist Configuration To configure the interval time of white list, please refer to the command below. 684 01 0 0 0 0 0 # {1} The interval time of White List Configuration Command Address: 684. {2} White List Number. 01~08 indicate white list No.1~No.8. {3} Interval Time. The command is shown below. Command Description Command Description Command Description 0s 10s 30s 1min 5min 5-10min User Defined {4} The user defined interval time: Thousands’ Digit {5} The user defined interval time: Hundreds’ Digit {6} The user defined interval time: Tens’ Digit {7} The user defined interval time: Digit {4}~{7} Valid only when {3} is 6. {8} End the command. Handset Number Settings To configure the handset number, please refer to the command below. 65 Control Panel User Manual 685 01 1 E0 ∙∙∙∙∙∙0 # {1} Handset Number Command Address: 685. {2} White List Number. 01~08 indicate white list No.1~No.8. {3} Handset No. Segment Command Command Description Command The first 16 characters of the 32 characters Command Description The last 16 characters of the 32 characters {4} The dialing number is 16 digits. The letter E at the beginning of {5} can be set as A, indicating “+”. The length of the each telephone number is 31 digits, and all the telephone number should be ended with *4. {5} End the command. Zone Report Type Configuration To configure the zone report type, please refer to the command below. 686 01 0 0 0 0 # {1} Zone Report Type Configuration Command Address: 686. {2} White List Number. 01~08 indicate white list No.1~No.8. {3} Set the value as 1 to send the report. Set the value as 0 not to send the report. Command Command Description Command Command Description Not Sending Sending {4} Zone No.: Hundreds’ Digit {5} Zone No.: Tens’ Digit {6} Zone No.: Digit When the Zone No. has no hundreds’ digit, {4} can be omitted. Example: When you want to send report of Zone No.16. The command is 68601116#. When the Zone No. has no hundreds’ digit and tens’ digit, {4} and {5} can be omitted. 66 Control Panel User Manual Example: When you want to send report of Zone No.8. The command is 6860118#. {7} End the command. After operating once, you can continuously configure with the command of {Project} + {Zone No.} + {#} 3.1.31 Schedule Configuration Enabling Weekly Schedule To enable the weekly schedule, please refer to the command below. 690 01 0 0 # {1} Enabling Weekly Schedule Command Address: 690. {2} Partition Number, 01~08 indicate partitions No.1~No.8. {3} Enable/Disable Mandatory Arming Command Command Description Command Command Description Disable Enable {4} It indicates to enable/disable the weekly schedule. Command Command Description Command Command Description Disable Enable {5} End the command. Weekly Schedule Time Parameter Configuration To configure the time parameters of the weekly schedule, please refer to the command below. 691 01 1 1 0 0 0 0 0 0 0 0 E # 3 4 5 6 7 8 9 10 11 12 13 14 {1} Weekly Schedule Time Parameter Configuration Command Address: 691. {2} Partition Number. 01~08 indicate partitions No.1~No.8. 67 Control Panel User Manual {3} Monday to Sunday Command Description Command Description Command Description Monday Tuesday Wednesday Thursday Friday Saturday Sunday {4} Time bucket composed by {5}~{12}. The value range is 1~8. {5}~{12} It indicates the start time and end time during the time bucket of {4}. Start Time: {5}{6}:{7}{8} End Time: {9}{10}:{11}{12} When you set the start and end time as 00:00 and 00:00, all the settings from the present time bucket to the maximum time bucket will be cleared. When you set the start and end time as non-zero, the previous time bucket must be non-zero. When you set the start and end time as non-zero, only Arming in {13} can be set. When you set the start and end time as non-zero, end time must be greater than start time in every time bucket. When you set the start and end time as non-zero, the start time must be 5min greater than the end time of the previous time bucket. When you set the start and end time as non-zero, if the time bucket is overlapped with the latter ones, or the difference between them is less than 5min, all the settings of the latter ones will be cleared. {13} Three types of Arming/Disarming. Command Command Description Command Command Description Command Command Description General Arming/Dis arming Real-time Arming/Disar ming Stay Arming/Disar ming {14} End the command. Copying Weekly Schedule To copy the settings of the day (n) to another day (l) of the week in partition (m), please refer to the command below. 68 Control Panel User Manual 692 01 0 0 # {1} Copy Weekly Schedule Command Address: 692. {2} Partition (m) Number. 01~08 indicate partitions No.1~No.8. {3} It indicates the value range of the day (n). Command Description Command Description Command Description Monday Tuesday Wednesday Thursday Friday Saturday Sunday {4} It indicates the value range of the day (l). Command Description Command Description Command Description Monday Tuesday Wednesday Thursday Friday Saturday Sunday {5} Completing Copy Weekly Schedule of Partition To copy the settings of partition (m) to partition (n), please refer to the command below. 693 01 02 # {1} {2} {3} {4} Copy Weekly Schedule of Partition Command Address: 693. Partition (m) Number. 01~08 indicate partitions No.1~No.8. Partition (n) Number. 01~08 indicate partitions No.1~No.8. End the command. Prior Schedule Date Parameter Configuration To configure the date parameters of the prior schedule, please refer to the command 69 Control Panel User Manual below. 694 00 0 0 0 0 0 0 0 0 0 0 # 4 5 6 7 8 9 10 11 12 13 {1} Prior Schedule Date Parameter Configuration Command Address: 694. {2} It indicates the prior schedule number. 00~30 indicate prior schedules No.00~No.30. {3} It indicates to enable/disable the mandatory arming/disarming. Command Command Description Command Command Description Disable Enable {4} It indicates to enable/disable the prior schedule. Command Command Description Command Command Description Disable Enable {5}~{12} It indicates the start date and end date. Start Date: {5}{6}/{7}{8}. The former is the month (value range 1~12), while the latter is the day (value range 1~30). End Date: {9}{10}/{11}{12}. The former is the month (value range 1~12), while the latter is the day (value range 1~30). {5} End the command. Enabling Prior Schedule To enable the prior schedule, please refer to the command below. 695 00 0 0 0 0 0 0 0 0 # 3 4 5 7 8 9 10 11 {1} Enabling Prior Schedule Command Address: 695. {2} It indicates the prior schedule number. 01~30 indicate prior schedule No.1~No.30. {3} Partition 1 {4} Partition 2 {5} Partition 3 {6} Partition 4 {7} Partition 5 {8} Partition 6 {9} Partition 7 70 Control Panel User Manual {10} Partition 8 {3}~{10} It indicates to enable/disable prior schedule of Partition No.1~No.8. Command Command Description Command Command Description Disable Enable {11} End the command. Prior Schedule Time Parameter Configuration To configure the time parameters of the prior schedule, please refer to the command below. 696 00 0 0 0 0 0 0 0 0 0 E # 7 8 9 10 11 12 13 3 4 5 6 {1} Prior Schedule Time Parameter Configuration Command Address: 696. {2} It indicates the prior schedule number. 01~30 indicate prior schedule No.1~No.30. {3} It presents the time bucket composed by {4}~{11}. The value range is 1~8. {4}~{11} It indicates the start time and end time during the time bucket of {3}. Start Time: {4}{5}:{6}{7} End Time: {8}{9}:{10}{11} When you set the start and end time as 00:00 and 00:00, all the settings from the present time bucket to the maximum time bucket will be cleared. When you set the start and end time as non-zero, the previous time bucket must be non-zero. When you set the start and end time as non-zero, only Arming in {12} can be set. When you set the start and end time as non-zero, end time must be greater than start time in every time bucket. When you set the start and end time as non-zero, the start time must be 5min greater than the end time of the previous time bucket. When you set the start and end time as non-zero, if the time bucket is overlapped with the latter ones, or the difference between them is less than 5min, all the settings of the latter ones will be cleared. {12} Three types of Arming/Disarming. Command Command Description Command Command Description Command Command Description General Arming/Dis arming Real-time Arming/Dis arming Stay Arming/Disar ming 71 Control Panel User Manual {13} End the command. Enabling Relay Schedule To enable the relay schedule, please refer to the command below. 697 0 # {1} Enabling Relay Schedule Command Address: 697. {2} It indicates to enable/disable the relay schedule. Command Command Description Command Command Description Enable Disable {3} End the command. Relay Schedule Relay Parameter Configuration To configure the relay parameters of the relay schedule, please refer to the command below. 698 0 0 0 0 # {1} Relay Schedule Relay Parameter Configuration Command Address: 698. {2} It indicates to delete/add the relay schedule. Command Command Description Command Command Description Delete Add {3} {4} {5} {6} Relay No.: Hundreds’ Digit Relay No.: Tens’ Digit Relay No.: Digit End the command. Relay Schedule Time Parameter Configuration To configure the time parameters of the relay schedule, please refer to the command below. 72 Control Panel User Manual 699 0 0 0 0 0 0 0 0 0 E # 4 5 8 9 10 11 12 {1} Relay Schedule Time Parameter Configuration Command Address: 699. {2} It presents the time bucket composed by {3}~{10}. The value range is 1~8. {3}~{10} It indicates the start time and end time during the time bucket of {2}. Start Time: {3}{4}:{5}{6} End Time: {7}{8}:{9}{10} When you set the start and end time as 00:00 and 00:00, all the settings from the present time bucket to the maximum time bucket will be cleared. When you set the start and end time as non-zero, the previous time bucket must be non-zero. When you set the start and end time as non-zero, only Enable in {11} can be set. When you set the start and end time as non-zero, end time must be greater than start time in every time bucket. When you set the start and end time as non-zero, the start time must be 5min greater than the end time of the previous time bucket. When you set the start and end time as non-zero, if the time bucket is overlapped with the latter ones, or the difference between them is less than 5min, all the settings of the latter ones will be cleared. {11} Enable/disable the relay schedule. Command Command Description Command Command Description Enable Disable {12} End the command. 3.1.32 Wireless User Permission Configuration To configure the permission of wireless users, please see the command below. 701 1 1 1 1 1 # {1} Wireless User Permission Configuration Command Address: 701~732. 701~732 indicate wireless users No.1~No.32. {2} Arming {3} Arming Report 73 Control Panel User Manual {4} Disarming {5} Disarming Report {6} Alarm Clearing {2}~{6} Command Command Description Command Command Description Supported Unsupported {7} End the command. 3.2 Keypad Alarm Operation Code 3.2.1 Device Initialization Control panel can be recovered through the alarm keypad initialization; see the command below. {Installer Code} + {*} + {8} + {9} + {#} The default password for the installer:012345. When doing initialization for the device, the No.1 partition is enabled by default and the partition-system mode of the global keypad cannot be switched to the global mode. When a non-No.1 partition is enabled, the global mode of the system will be enabled automatically. 3.2.2 Control panel Arming and Disarm The operation of control panel arming and disarming is the same. Take the password 1234 as an example, and the command is shown below. {1} +{2} + {3} +{4} +{#} After the operation is completed, the arming status of the control panel will be changed (the status of arming will be exchanged into disarming), vice versa. Operation method: {User password} + {*} + {1} + {7} + {#}.Take the password 1234 as an example, and the command is shown below: {1} + {2} + {3} + {4} + {*} + {7} + {#} After the operation is completed, the partition will change the status of disarming (current status) into arming immediately. The exiting delay of partition is 0. 3.2.3 Stay Arming Operation Method: {User password} + {*} + {4} + {#}.Take the password 1234 as an 74 Control Panel User Manual example, and the operation is shown as follows: {1} + {2} + {3} + {4} + {*} + {4} + {#} After the operation is completed, the partition will change the status of disarming (current status) into arming immediately. The bypass-supported zone of the partition will do auto-bypass simultaneously. 3.2.4 Zone Bypass/Recovery After bypassing a zone, all the alarm devices in this zone will be blocked. ; see the command below {User password} + {bypass} + {Zone Number} + {#} For continuous bypass/ recovery; see the command below: [Bypass]+[ 8]+[ # ] [Bypass]+[1]+ [#][Bypass]+ [2]+[#] …… [1234]+ 15 Seconds Continuous operation of multi-zone bypass/ recovery should be completed within 15 seconds 3.2.5 Group Bypass After a partition is conducted with group bypass, all the alarm devices in group-bypass supported zone of the partition will be blocked. See the command below. {User Password} + {*} + {4} + {1} + {#} 3.2.6 Group Bypass Recovery After recovering the group bypass of a partition, all the alarm devices in group-bypass supported zone of the partition will be revalidated. See the command below. {User Password} + {*} + {4} + {2} + {#} 3.2.7 Canceling Keypad Alarm When the alarm is trigged, it can be canceled by keypad. The alarm can be canceled both under the arming and the disarming status. Alarm Clearing under the Arming Status Operation Method: {User Password} + {*} + {1} + {#} Alarm clearing under the disarming Status 75 Control Panel User Manual Operation Method (1): {*} + {1} + {#} Operation Method(2): {Users Password} + {*} + {1} + {#} 3.2.8 Alarm Output Operation For enabling alarm output of the alarm keypad, see the command below. {Password} + {*} + {8} + {5} + {n} + {#} For disabling alarm output of the alarm keypad, see the command below. {Password} + {*} + {8} + {6} + {n} + {#} The control panel supports 16 channels of alarm outputs, the N valuation should be 1-16. 3.2.9 Emergency Alarm Press the {PANIC} button on the alarm keypad for 3 seconds or more. The emergency alarm will be triggered after a double-beep sound. 3.2.10 System Status Query In query mode, there are special meanings (see the table below) for the 8 indicators on alarm keypad. Press the {Status} key for current system information Query. Serial Number Meaning Serial Number Meaning AC Power Loss Keypad Disconnection Low Battery Network Disconnection Tampering Alarm Enabling GPRS Exception Telephone line Disconnection Expansion Bus Exception 76 Control Panel User Manual 3.2.11 Control Panel and Wireless Device Connection The steps of connecting wireless device with the control panel are shown as follows. 1. Enter the command of {password} + {*} + {91} + {wireless device No.} + {#} with the RF keypad to enter the connection mode. 2. Press any key on the keyboard to complete the connection. 3.2.12 Deleting the Specified Connected Wireless Device Follow the command below to delete the connected wireless device. {password} + {*} + {90} + {wireless device No.} + {#} 3.2.13 Deleting all the Connected Wireless Device Follow the command below to delete all the connected wireless devices. {password} + {*} + {92} + {#} 3.2.14 Main Operator Password Changing The user password can be changed by main operator. The operations are divided into following steps: Steps: 1. {Master Code} } + {*} + {0} + {#} 2. {User Number} + {#} 3. {New Password} +{#} 4. {New Password}+{#} The password will be changed by the above four steps The User Number must be expressed into three digits, such as 002. 3.2.15 Control Programming Operation The control panel can be configured via alarm keypad operation; configuration process is generally divided into three steps: Steps: 1. Enter the programming mode; see the command below: {Installer Code} + {*} + {0} + {#} 2. Control panel configuration operation (see section 4.1) 3. Exit programming mode; see the command below: {*} + {#} 77 Control Panel User Manual 3.2.16 Entering Partition See the command below to enter the partition. {*} + {3} + {n} + {#} 3.2.17 Alarm Center Test Partition keypad operation is used to test the communication between control panel and the alarm center; see the command below: {password} + {*} + {6} + {1} + {#} One operation generates one test report. It is used to test the communication between the control panel and center after installing the system or during the inspection. 3.2.18 Project Mode Enter the project mode to debug alarm control panel; see the command below: {password} + {project} + {9} + {0} + {n} + {#} Long press {Project} / {State} or {*} {#} key to exit the project mode after debugging. When the evaluation of n is 1 or 2, the handset 1 and 2 are in dialing status. When the evaluation of n is 3 or 4, the network center1 and 2 are in uploading status. When the evaluation of n is 5 or 6, the GPRS center is 1 and 2 are in uploading status. 3.2.19 Enabling/Disabling Key Tone For keypad tone status switch, see the command below: {*} + {5} + {1} + {#} 3.2.20 LCD Backlight Control For LCD backlight control; see the command below: {*} + {5} + {2} + {n} + {n} + {n} + {#} {n}{n}{n}refers to the light duration in seconds, and 999 means the LCD is always light The default duration is 900 seconds, and the parameters will be restored after reboot. 3.2.21 LCD Backlight off For Disabling the LCD backlight, see the command below: {*} +{8} + {#} 78 Control Panel User Manual 3.2.22 Pacing The pacing function is used for debugging; see the command below: {password} + {*} + {6} + {0} + {#} The function of pacing is only available under the status of disarming and non-fault of the zone. The system will do auto-arming in the pacing mode without reporting any CID log. The siren will start warning after the alarm is triggered and stop warning if the alarm is dismissed. If the zone is disarmed, it will exit the pacing mode automatically. 3.2.23 SMS Arming/Disarming The control panel supports SMS arming/disarming, the command is shown below: Away arming for the partition {121} +{#} +{Partition No.} + {#} Instant arming for the partition {122} +{#} +{Partition No.} + {#} Stay arming for the partition {123} +{#} +{Partition No.} + {#} Partition disarming {120} +{#} +{Partition No.} + {#} Partition alarm clearing {#} +{100} +{#} +{Partition No.} + {#} The partition No. is with three digits. for example. If the partition No. is 1. The command of partition alarm clearing is {#} +{100} +{#} +{001} + {#} 3.2.24 Control Panel Soft Recovery For control panel soft recovery; see the command below: {master code} + {*} + {6} + {8} + {#} All unissued CID logs will not be reissued. Newly generated report will be issued after system recovery. The timer of the test report will not be cleared, and will remain the value before recovery till the recovery processes being completed. 79 Control Panel User Manual 3.2.25 Current Fault Tone Disabling To disable the current fault tone; see the command below: {*} + {5} + {6} + {#} If there are new faults, the prompt sound will re-Tip. 3.2.26 Test Report Manually Relaying To relay test report manually; see the command below: {password} + {*} + {6} + {1} + {#} One operation generates one test report. It is used to test the communication between the control panel and center after installing the system or during the inspection. 3.2.27 Keypad Locking and Unlocking If a user failed to operate for five times, the keypad will be locked for 30 seconds. During the lock duration, the keypad backlight blinks and all of the key operations are invalid. The keypad will be unlocked after 30 seconds. 3.2.28 Exiting the Operation See the command below to exit the operation. {*}{#} 80 Control Panel User Manual Chapter 4 Accessing by Client Software Check the package contents and make sure that the device in the package is in good condition and all the assembly parts are included. 4.1 Installing the iVMS-4200 Insert the installation media of iVMS-4200 into the appropriate computer. Perform the following steps to install the iVMS-4200 client software. 1. Double-click the program file to enter the welcome panel of the InstallShield Wizard. Click Next to start the InstallShield Wizard. 2. Read the License Agreement. Click Print if you want to print the license agreement. 81 Control Panel User Manual 3. If you accept the terms of the license agreement, click I accept the terms of license agreement. Click Next to continue. Otherwise click I do not accept the terms of the license agreement, and then click Cancel to cancel the installation On the next panel , you are prompted to select the function module to install. Set installation directory where the client software is to be installed. You can either accept the default directory that is displayed, or click Browse and select a different directory. The default directory is C:\Program Files\iVMS-4200 Station\iVMS-4200. 4. Click Next to continue. Install the WinpCap plug-in according to the prompts to detect the online devices when running the client software. 82 Control Panel User Manual 5. Read the pre-install information and click Install to begin the installation. 6. A panel indicating progress of the installation is displayed. A percentage completion bar is updated as the installation progresses. 83 Control Panel User Manual 7. Select the setup type according to your need. You can check the checkbox of Create Desktop for Client to create a shortcut icon on the desktop for the client software. 8. Read the post-install information and click Finish. 84 Control Panel User Manual 4.2 User Registration and Login For the first time to use iVMS-4200 software, you need to register a super user for login. Steps: 1. Input the super user name and password. 2. Confirm the password. 3. Optionally, check the checkbox of Enable Auto-login to log in the software automatically. 4. Click Register. Then, you can log in the software as the super user. A user name cannot contain any of the following characters: / \ : * ? “ < > | The password cannot be empty and the length of the password should be no less than six characters. When opening iVMS-4200 after registration, you can log in the software with the registered user name and password. Steps: 1. Input the user name and password you registered. 85 Control Panel User Manual 2. 3. Optionally, check the checkbox of Enable Auto-login to log in the software automatically. Click Login. 4.3 Network Security Control Panel Settings Purpose: In this section, you are able to configure or view the basic parameters (such as the system information, alarm information, network data, device status and so on) of the security control panel. Click Tool>Device Management to enter the interface 4.3.1 Add/Edit/Delete the Device Add a Device: Steps: 1. Select Security Control Panel as the device type on the Organization list. 2. Click Add Device to open the device adding dialog box. 3. Select IP/Domain as the adding mode. 4. Input the required information. Nickname: Edit a name for the device as you want. Address: Input the device’s IP address or domain name. Port: Input the device port number. The default value is 8000. User Name: Input the device user name. Password: Input the device password. 5. Optionally, you can check the checkbox Export to Group to create a group by the device 86 Control Panel User Manual 6. name. All channels and alarm inputs of the device will be imported to the corresponding group by default. Click Add to add the device. For first time adding the control panel, you need to add Security Control Panel to the organization as a new device type. Steps: 1. Click Add New Device Type to enter the interface. 2. Check the checkbox of Security Control Panel. 3. Click OK to complete the settings. Edit a Device Purpose: You can edit the device information in this section, including the device name, address and port number. Steps: 1. On the Device Management interface, click and select a control panel in the device list. 2. Click on the Modify button on the upper side of the list to enter the device modify interface. 3. Enter the required nick name, address, and port number and then enter the admin username and password. 4. Click Modify to save the changes. Delete a Device Select device from the list, click Modify/Delete, and then you can modify/delete the information of the selected device. 87 Control Panel User Manual 4.4 Security Control Panel Remote Control In this section, you can control the panel remotely to implement operations such as arming, disarming, bypass, group bypass, and so on for both the partitions and zones. Click View>Control Panel to enter the main control panel of the client In the main Control Panel of the client, Click Security Control Panel to enter the interface. 88 Control Panel User Manual 4.4.1 Partition Remote Control In this section, you can remotely implement operations of away arming, stay arming, instant arming, disarming, clearing alarm, group bypass, and recovering group bypass for the configured partitions. Steps: 4. On the Partition (Sub-system) page, click and select one or more partitions to be controlled, or check the check box of Select All on the upper-right side of the page to select all partitions. 5. Click the operations buttons (away arming, stay arming, instant arming, disarming, clearing alarm, group bypass, and group bypass recovery) on the upper side of the page. You can also click the icon to get the operation menu for each partition. 3. Click Associated Zone to view the zones of the current partition. 89 Control Panel User Manual You can add/remove the selected zones into/from the group. Click View, and you can view the status of the zone. The function of Live View is only supported by the security control panel with video input module. 4.4.2 Zone Remote Control In this section, you can remotely implement bypass, or recovering bypass for the zones. Steps: 1. Click Zone tag to enter the interface. 90 Control Panel User Manual 2. 3. 4. Click and select one or more zones to be controlled. Click Bypass/Bypass Recovery on the upper side of the page to control the selected zones. Click View, and you can view the status of the zone. 5. Click the icon to bypass or recover a zone separately. : the zone is bypassed. : the zone is recovered. The function of Live View is only supported by the security control panel with video input module. 4.5 Remote Configuration Purpose: In this section, you are able to configure device parameters remotely. Click the Remote Configuration button to enter the interface. 91 Control Panel User Manual 4.5.1 System Information Configuration Purpose: In this section, you can configure the system parameters (such as time, log, user, security, system maintenance and so on) for the device. 92 Control Panel User Manual Timing Configuration Before You Start: Before you start configuring the security control panel, you need to do timing for the device first. Enter Remote Configuration>System->Time to get the configuration page. Click the Synchronization button to complete the settings. 93 Control Panel User Manual User Configuration Purpose: You can add, edit, or delete the network operator and keypad operator in this section. Network User Add a Network User Steps: 1. Enter the user configuration interface. Remote Configuration->System->User 94 Control Panel User Manual 2. Click to enter the interface of adding a network user. 3. Enter the corresponding user information including the user type, user name, 95 Control Panel User Manual password, IP address, and MAC address. 4. Select the permission of the user. 5. Click OK to finish the settings. Edit a User Steps: 1. Click to enter the interface of editing the selected user. 2. Edit the corresponding user information including the user type, user name, password, IP address, and MAC address 3. Edit the permission of the user. 4. Click OK to finish the settings. Delete a user Steps: 1. Select a user needs to be deleted. 2. Click to delete the user. Keypad User The control panel supports at most 16 keypad operators. 96 Control Panel User Manual Steps: 1. Select the user type. Operator and installer can be selected. 2. Select the index number of the keypad user, up to 16 numbers can be selected. 3. Enter the name of the keypad operator. 4. Enter the password of the operator. 5. Click the dropdown menu to select the user permission. 6. Click Apply to save the settings. 4.5.2 Network Configuration Purpose: You can edit the general network parameters in this section. General Network Parameters Configuration Steps: 1. Enter the general network configuration page. Remote Configuration-> Network->General 97 Control Panel User Manual 2. Configure the NIC settings, including the IPv4(IPv6) Address, IPv4(IPv6) Subnet Mask and IPv4(IPv6) Default Gateway. 3. Click Apply to save the above settings. The valid value range of Maximum Transmission Unit (MTU) is 500 ~ 9676. The default value is 1500. The Multicast sends a stream to the multicast group address and allows multiple clients to acquire the stream at the same time by requesting a copy from the multicast group address. Before utilizing this function, you have to enable the Multicast function of your router and configure the gateway of the control panel. DDNS Configuration Purpose: If your control panel is set to use PPPoE as its default network connection, you can use the Dynamic DDNS for network access. Before you start: Registration on the DDNS server is required before configuring the DDNS settings of the control panel. Steps: 1. Enter the DDNS Settings interface: Remote Configuration> Network > DDNS 98 Control Panel User Manual 2. Check the Enable DDNS checkbox to enable this feature. 3. Select DDNS Type. 4. Enter the Server Address of the IP Server. 5. Click Apply to save the settings. The Server Address should be entered with the static IP address of the computer that runs the IP Server software. For the IP Server, you have to apply a static IP, subnet mask, and gateway and preferred DNS from the ISP. Uploading Mode Configuration Purpose: You can select to send Zone report, alarm report and configure the uploading mode of the selected center group in this section. Steps: 1. Enter the uploading mode configuration page. Remote Configuration->Uploading Mode Settings 99 Control Panel User Manual 2. Click the drop down menu to select a center group. 3. Check the Enable checkbox to enable the configuration 4. Check the checkbox to select the required Zone for sending the Zone report for the Zones without Zone report. At most 6 center groups can be inter-combined to send the alarm report. 5. Check the checkbox to select the type of non-Zone alarm report. 6. Click each dropdown menu to configure the uploading channel. 7. Click Apply to save the settings. The alarm channel of each center group should be configured in order. Network Center Configuration Purpose: In this section, you can configure the parameters(such as server type, IP address, port No.,and so on)of the network center. Steps: 1. Enter the network center configuration page. Remote Configuration->Network Center 100 Control Panel User Manual 2. Click and select a network center. Two centers are selectable. 3. Click the dropdown menu to select a sever type. Two sever types are available: IP4/IP6 and domain. 4. Enter the IP address that is used to communicate with the network alarm receiving center. 5. Enter the port No. for communicating with the alarm-receiving center. 6. Click the dropdown menu to select the protocol type. 7. Enter the username that is applying for displaying in the alarm-receiving center. The length of the username should be 6 characters. Only numeric (0~9), and letter (A~F&a~f) are valid for this username. Dialing Center Configuration Purpose: You can configure the parameters(such as report uploading time period, center name, phone number and so on) for each dialing center in this section. Steps: 1. Enter the dialing center configuration page. Remote Configuration->Call Center 101 Control Panel User Manual 2. Check the checkbox to enable report uploading. 3. Enter the report-uploading period (unit: hour). The report-uploading period represents the time interval between uploading the first report and the next report. 4. Enter the first report uploading time interval (unit: minute). The first report uploading time interval represents the time interval between enabling the report uploading function and sending the first report. 5. Select a center type. 6. Enter the center name and phone number. 7. 8. 9. 10. 11. The maximum length of center name is 32 characters. The phone number should be 31 characters and the input mode is {No.}{Dwell Time}{EXT No.}. For example, in the number of 000088075998FFF8180, the letter F (which means 2 seconds) represents the dwell time, if the number of the letter F is N, the dwell time is N*F seconds. The number of F is suggested to be more than 3, which means the dwell time should be more than 6 seconds. Enter the dialing times (1~15). The dialing times represents the times that the control panel trying to communicate the alarm receiving center. Select the Pstn protocol. Select the Pstn transmission mode: DTMF5/S and DTMF10/S. Enter the receiver ID which is the authentication account while doing the communication with the alarm receiving center. Click Apply to save the settings. 102 Control Panel User Manual Wireless Center Parameter Settings Steps: 1. Enter the wireless center parameter settings page. Remote Configuration->Network->Wireless Center 2. Click the dropdown menu to select the net center. 3. Enter the device ID which is applying for displaying in the alarm receiving center. 4. 5. 6. 7. The length of the username should be 6 characters. Only numeric (0~9), and letter (A~F&a~f) are valid for this username. Enter the IP address that is used to communicate with the wireless alarm receiving center. Enter the port No. for communicating with the alarm receiving center. Click the dropdown menu to select the protocol type. Click Apply to save the settings. Advanced Network Parameters Settings Steps: 1. Enter the advanced network configuration page. Remote Configuration->Network->Advanced Settings 103 Control Panel User Manual 2. Enter the corresponding DNS sever address. 3. Enter the IP address and port No. of the control panel. 4. Click Apply to save the settings. Whitelist Configuration Purpose: The whitelist is the list of phone numbers which are authorized to interact with the control panel. Steps: 1. Enter the whitelist configuration interface. Remote Configuration->Network->Configure Whitelist 104 Control Panel User Manual 2. 3. 4. 5. Select the index of the whitelist. Check the Enable checkbox to enable the configuration. Enter the phone number of the whitelist into the SIM Card Number text box. Select the identical message time interval that represents the interval of sending message triggered by the same event. 6. Select the permission of the whitelist on the permission panel. 7. Click Apply to save the settings. 4.5.3 Alarm Configuration Partition Configuration Purpose: You can configure the detailed alarm parameters of the zone in the partition in this section. Steps: 1. Enter the partition alarm triggering configuration interface. Remote Configuration->Alarm->Partition 105 Control Panel User Manual 2. Click the partition dropdown menu to select a partition. 3. Click the Linkage button to add required Zone, keypad, or keypad user to the partition. 4. Check the check box of Enable Partition or Public Partition to enable functions of the partition or set the system as a public system. 5. Enter the Entering Delay and Existing Delay duration (unit: second). 6. Enter the siren-delay time (unit: second). The siren-delay time represents the duration of siren ringing when the alarm of the partition is triggered. 7. Click Edit to edit the arming schedule. Select the alarm type. 8. Select an alarm type. 106 Control Panel User Manual Duress Report: Enable uploading the duress report of control panel. Arming/Disarming Report Uploading Sound: Enable the prompt sound when uploading the arming/disarming report. Alarm Sound Uploading Manual Test: Enable the prompt sound when successfully uploading the manual test report. Arming Partition in Key switch Zone: Support the key Zone to arm the current partition Send Report when Arming Key Switch Zone: Enable uploading report when the key Zone arms the current partition. Disarming Partition in Key switch Zone: Support the key Zone to disarm the current partition Send Report when Arming Key Switch Zone: Enable uploading report when the key Zone disarms the current partition. 9. Click Apply to save the settings. Zone Configuration Steps: 1. Enter the Zone configuration interface. Remote Configuration-> Alarm-> Arming Zone 2. Click the Partition dropdown menu to select a partition. 3. In the Alarm Input list, select an alarm input channel and click the icon Zone configuration page. 107 to enter Control Panel User Manual 4. Edit the general information of the Zone, including name, probe type, arming Zone type, sensitivity, entering delay, and existing delay and so on. Probe Type: Select the type of the detector. Arming Zone Type: Select the type of Zone in the partition Sensitivity: Select the response time of the Zone. 5. Select the linked siren and linked relay. 6. Click Copy to to copy all these settings to other Zones. 7. Click Apply to save the settings. Relay Configuration Steps: 1. Enter the Zone configuration interface. Remote Configuration-> Alarm-> Relay 108 Control Panel User Manual 2. In the Alarm Output list, select an alarm input channel and double click the relay to enter zone configuration page. 3. Edit the general information of the zone, including name, output delay and so on. Output Delay (0~5999s): Configure the alarm output time after the alarm being triggered. 4. Click the dropdown menu to enable/disable the event-linked relay. 5. Select the detailed operation after the alarm being triggered on the partition event panel. 6. Select the global event of alarm triggering. 109 Control Panel User Manual 7. Click Copy to to copy all these settings to other Zones. 8. Click Apply to save the settings. Siren Configuration Steps: 1. Enter the siren configuration page. Remote Configuration->Alarm->Siren 2. 3. 4. 5. Click the Siren dropdown menu to select a siren needs to be configured. Check the Enable box to enable the configuration. Edit the siren name. Select the detailed operation after the alarm being triggered on the partition event panel. 6. Select the global event of alarm triggering. 7. Click Apply to save the settings. Relay Output Schedule Configuration Purpose: You can set the schedule for turning on/off the relay in this section. Steps: 1. Enter the relay output schedule configuration interface. Remote Configuration->Alarm-> Output Schedule Rule 110 Control Panel User Manual 2. In the relay list, select an alarm input channel and click the icon configuration page. to enter the Zone 3. Check the Enable checkbox to enable the configuration. 4. Click the icon , click and drag the mouse on the time bar (the time bar is divided into 24 segments which represent 24 hours) to draw the required schedule. Delete Schedule: click the drawn color bar and click the icon to delete the color bar. 111 Control Panel User Manual Clear Schedule: Click the icon to clear the drawn the schedule. 5. Check the Relay checkbox to select the relay. 6. Click Apply to save the settings. Partition Arming/Disarming Schedule Configuration Steps: 1. Enter the arming/disarming schedule configuration interface. Remote Configuration->Alarm ->Partition Scheduling Arming/Disarming 2. Select a partition needs to be configured. 3. Check the Enable Normal Schedule checkbox to enable daily schedule for the partition. You can select to enable the mandatory arming function. 4. Click the icon of the Template box to enter the schedule configuration interface. 112 Control Panel User Manual 5. Click Edit to enable the schedule configuration. 6. Click and select a template. 7. Click the button to select an arming type. 8. Click and drag the mouse on the time bar to draw the daily schedule. Delete Schedule: Click the drawn color bar and click the icon to delete the color bar. Clear Schedule: Click the icon to clear the drawn the schedule. Copy Schedule: Click the drawn color bar and click the icon to copy this arming schedule to other day of the week. 9. Click Save to save the settings and click Cancel to exit the page. 10. Click Copy to to copy all these settings to other Zones. 11. Click Apply to save the settings. Arming/Disarming Preferential Schedule Configuration Steps: 1. Enter the arming/disarming preferential schedule configuration interface. Remote Configuration->Alarm->Preferential Schedule Arming/Disarming 113 Control Panel User Manual 2. Click the drop down menu to select the time duration. 3. Click the icon to enter the preferential schedule configuration page. 4. 5. 6. 7. 8. Click the button to select an arming type. Click and drag the mouse on the time bar to draw the daily schedule. Click Save to save the settings and click Cancel to exit the page. Click Copy to to copy all these settings to other Zones. Click Apply to save the settings. 114 Control Panel User Manual Module Information Purpose: You can view the information of external keypad and relay in this section. Steps: 1. Enter the module information interface. Remote Configuration->Alarm->Module Information 2. Click and select the external device from the module type dropdown menu. 3. View the information about the selected device. Zone Tampering-proof Configuration Steps: 1. Enter the Zone tampering configuration interface. Remote Configuration->Alarm->Region Tampering Proof 115 Control Panel User Manual 2. Click dropdown menu to select a Zone needs to be configured. 3. Select a tampering type. 4. Check the Upload Alarm Recovery Report checkbox to enable the function of uploading alarm recovery report. 5. Select the linked siren on the Linked Siren panel. 6. Select the linked relay on the Linked Relay panel. 7. Click Copy to to copy all these settings to other Zones. 8. Click Apply to save the settings. Remote Control Permission Configuration Steps: 1. Enter the key fobs permission configuration interface. Remote Configuration->Alarm->Remote Control Permission 2. Click the icon to enter the key fobs permission configuration page. 116 Control Panel User Manual 3. 4. 5. 6. 7. Check the Enable checkbox to enable the configuration Enter the serial number of the key fobs. Select the partition No. needs to be controlled. Check the checkbox and select the permission for the key fobs. Click Apply to save the settings. 4.6 Others 4.6.1 Fault Handling In this section , you can select the fault detection type, alarm linked keypad and output mode. Steps: 1. Enter the fault handling interface. Remote Configuration->Others->Fault Handling 117 Control Panel User Manual 2. Select the fault detection type. 3. Click the Source of Fault dropdown menu to select the linked keypad. 4. Select the alarm output mode and corresponded fault detection type. The alarm output mode can be selected as Linked Indicative Light and Linked Keypad Sound. 5. Click Apply to save the settings. 4.6.2 Printer Configuration In this section , you can select to enable/disable the printer and the printing content. Steps: 1. Enter the printer configuration interface. Remote Configuration->Others->Printer Configuration 118 Control Panel User Manual 2. Check the checkbox to enable the printer. 3. Select the content to be printed, including time, fault, alarm information, device information, and operation information. 4. Click Apply to save the settings. 4.7 Operation You can configure the partition, zone, relay, siren, and fault warning audio in this section. Click Remote Configuration->Operation to enter the interface. Partition: you can arm/disarm the partition, clear alarm, bypass, and recover bypass of the system. Zone: you can bypass or recover bypass of the selected zone. Tigger: you can select to turn on/off the selected relay. Siren: you can enable/disable the specified siren. Fault Warning Audio: you can select the faulted keypad and select to disable the warning audio. 119 Control Panel User Manual 4.8 Status You can view status of the partition, zone, relay, siren ,and storage battery in this section. 120 Control Panel User Manual 121 Control Panel User Manual Chapter 5 Trouble Shooting Q: What is the function of Project button of LCD keypad? A: Project button has button switch function besides normal instruction button, such as: When sensor or module is abnormal, press and hold the Project button to switch to other interfaces manually. When the sensor/module is abnormal or the keypad, press the Project button once and the current display interface will be paused for 20s; press it again to switch to the next LCD screen interface. Q: How to manually switch to other abnormal interfaces when the LCD keypad displays sensor/module is abnormal? A: 1. Among the LCD keypad abnormal display interfaces, display interface of the sensor alarm, module abnormal display interface are of first priority; the sensor abnormal interface is of second priority, sensor bypass interface is of third priority. 2. If interfaces of different priority exist at same time, the system automatically displays the interface of first priority. 3. The switch between interfaces of same priority: there are two ways to switch display interface of the sensor alarm to sensor off-line display interface. 1) System auto-switch: The system will refresh automatically. If the current display interface is accomplished and other interfaces of same priority exist, system will auto switch to other interfaces. 2) Manually switch: Press the Project button continuously until it switches to the interface to display. 4. Switch between interfaces of different priority: from sensor alarm interface to sensor bypass interface: Press and hold the Project button for multiple times until it switches to the interface to display. Q: What is the meaning of LCD keypad Arm/Disarm, Operate indicators? A: LCD system keypad indicator: 1. The meaning of Arm/Disarm indicator (Red and Green) is shown below: Working Status Indicator Status Working Status Indicator Status Enter programming Green, Blink Parameters Initialization Green, Blink System Arming Red, Normally On System Disarming Green, Normally On 2. The meaning of Operate indicator (Green) is shown below: 122 Control Panel User Manual Working Status Indicator Status Working Status Indicator Status Enter programming Green, Blink Parameters Initialization Green, Blink System Abnormal Green, Blink System Normal Green, Normally On Q: What are the steps of LED keypad to program the control panel? A: 1. In overall keypad programming mode, the program command is: {installer password} + {*} + {0} + {#}; 2. To view the configuring operation for alarm control panel, please refer to alarm keypad configuring code; For example: program user password 2#, the password has arm/disarm function, does not send arming report, does not allow bypass, password is 5678, and the program code is shown as follow: Command Code Arming Type Password End {0}{0}{2} {3} {5}{6}{7}{8} {#} 3. Set program command There are 2 alert sound of correct or 5 alert sound of error and corresponding OSD notices after each program command is over. When 5 alert sound of error is heard and the screen displays Operation Failed, there is error in program command setting and the user need to reset correct program command. When 2 alert sound of correct is heard and the screen displays Operation Succeeded but the setting parameters are not the parameters needed, you can operate according to program command once again. 4. Exit program mode, the program command is: {*} + {#}. Q: What is the meaning of LED keypad Arm/Disarm, Operate, Camera indicators? A: LED alarm keypad Arm/Disarm indicator: Working Status Indicator Status Working Status Indicator Status Armed Red, Normally On Enter Programming Green, Blink Disarmed Green, Normally On Main Operator Change Password Green, Blink LED alarm keypad Operate indicator: Working Status Indicator Status Working Status Indicator Status Normal Green, Normally On Keypad Not Logged In Red, Blink System Error Orange, Blink Enter Programming Green, Blink Project Red, Normally On Change Password Green. Blink 123 Control Panel User Manual LED alarm keypad Camera indicator: Working Status Indicator Status Working Status Indicator Status Sensor Normal Off Sensor Error Red, Normally On Sensor Alarm Red, Blink Sensor Bypass Green, Normally On LED keypad Camera indicator under Project Mode: No. Description No. Description Off-hook Send CID Report Dial Receive Alert Sound Alarm Connecter Disconnection Control Panel Off-hook Receive the Hand-shack Sound Alarm Connector On-hook LED keypad Camera indicator under Status Mode: No. Description No. Description AC Power off Keypad Off-line Battery Low Voltage Network Cable Off-line Control Panel Tamper-proof On No SIM Card ADSL Cable Off-line Reserved Q: What is the meaning of LED keypad alert sound? A: The meaning of LED keypad alert sound is as follows: No. Keypad Alert Sound Description 1 Sound Keypad Prompt, Error Operating Prompt 2 Sound Correctly answered, succeeded 5 Sound Incorrectly answered, report uploading failed in 60s Last for 2s Intermittent Slow Sound, Continuously Enter/Exit Delay Intermittent Rapid Sound, Continuously Enter/Exit Delay, 10s Left Rapid Beep report Error Prompt Sensor Alarm, Keypad not logged in 124 uploading Control Panel User Manual No. Keypad Alert Sound 3 Long 2 Short Description Keypad Tamper-proof On Q: How to remove alarm memory? A: There are two situations of removing alarm memory as shown below: 1) Under disarming mode: Press {*} + {1} + {#} or {Password} + {*} + {1} + {#}. 2) Under arming mode: Press {Password} + {*} + {1} + {#}. Q: How to input hexadecimal number? A: Input hexadecimal number with {*} button and number button {0} ~ {5}. Conversion Table Hexadecimal Number Corresponding Key *0 *1 *2 *3 *4 *5 Q: How to set LED keypad address? A: Set LED keypad address with the DIP address of keypad. 125 Control Panel User Manual DIP Add ON 3 4 ON 3 4 3 4 ON 3 4 3 4 ON 3 4 3 4 ON 1 2 24 3 4 3 4 13 3 4 3 4 3 4 3 4 3 4 21 3 4 1 2 3 4 3 4 ON 25 29 22 30 DIP 3 4 3 4 11 DIP 15 DIP 3 4 19 DIP 3 4 3 4 3 4 23 DIP ON DIP 3 4 ON 26 ON DIP ON DIP ON DIP 3 4 DIP 14 18 DIP ON DIP ON DIP ON DIP 1 2 DIP 10 3 4 ON 17 ON DIP 3 4 Add ON DIP 1 2 DIP DIP ON DIP ON 3 4 ON 28 ON DIP 3 4 3 4 ON DIP 3 4 ON DIP 20 ON 16 DIP 1 2 Add DIP 1 2 DIP ON DIP ON 12 ON DIP 1 2 3 4 DIP ON DIP ON DIP ON ON DIP 1 2 Add ON DIP DIP 27 DIP 31 Q: Why is it needed to input E at the end of keypad configured phone number? A: Control panel can process phone number with 31 characters. Input number with 16 characters in each command address so that 2 addresses are needed for storage phone number. However, the phone numbers are different in every place so the control panel needs a special data bit to check if the phone number is complete. Character E ({*} {4}) is for checking if the phone number is complete. For example: The first Alarm connecter phone number is 0571-88075998, user can input the following command: Command Address 460 0 5 7 1 8 8 0 7 5 9 9 8 E For example: The first alarm connecter phone number is 17951-88075998, user can input the following command: Command Address 460 1 7 9 5 1 F F F 8 8 0 7 5 9 9 8 Command Address 461 126 Control Panel User Manual For example: The first alarm connecter phone number is 0571-88075998-8888, user can input the following command: Command Address 460 0 5 7 1 8 8 0 7 5 9 9 8 F F F 8 Command Address 461 8 8 8 E Q: What are notes for setting password? A: The password for each operator should be different; otherwise the setting will be failed. For example, if the password of operator 1 is set to be 1234 hen password of operator 2 is also 1234, it will prompt to be error. In addition, the password of each operator should be different from the control panel duress code of other operators; otherwise the setting will be failed. For example if the password of operator No.3 is 3456 and the password of operator No.4 is set to be3455 or 3457, it will prompt to be error. Q: What are notes for setting duress code? A: 1. The description of duress code is as follow: Input duress code when the user is under duress, it will work as if the user inputs valid password, but the system will auto-upload the alarm information. For example when a criminal forces the user to disarm the alarm, user can input the control panel duress code to disarm the system and upload the alarm information to the center automatically and off the criminal’s guard. 2. Please note when setting duress code: duress code is the valid password with its last number±1. For example: Valid Password: 1234, Duress Code: 1235 and 1233. For example: Valid Password: 1230, Duress Code: 1231 and 1239. For example: Valid Password: 1239, Duress Code: 1230 and 1238. 3. Please take the following notes while using duress code: While using duress code, it is needed to enable duress report firstly, as to program the control panel duress report and delay. The programming command to enable Control Panel Duress Report is as follow: Command Address {4}{6}{4} Enter Delay {3} Exit Delay {6} Siren Working Duration {2} Control Panel Duress Report {1} End {#} Q: How to solve the problem of two LED keypad address being same? A: When two LED keypad addresses are the same, the situation of two keypads demanding bus communication at the same time will appear and cause conflict. The only solution is to remove one keypad and reset the other keypad to an unused legal address. Restore the control panel by processing program code ({Main Operator}{*}{6}{8}{#}) 127 Control Panel User Manual Q: Why there is no Disarming Report? A: To make sure the user has permission of Disarming Report, please refer to Operator Configuration. Q: What to do if the user cannot disarm after arming the system? A: There are two different situations: 1. The user does not have permission to disarm, please contact the administrator. 2. Take the follow instructions when there is only one user in the system without permission to disarm; 1) Initialize the hardware, restore the password of operator, main operator password and permission, and then disarm with main operator. The initialization password of operator is: 012345, the initialization password of main operator is: 1234, the permission is: arm/disarm. There is arm/disarm report and bypass is permitted. Please refer to FAQ of hardware initialization for more information about hardware initialization. 2) The command code to restore factory parameters: {Password of operator} + {*} + {8} + {9} + {#}. This method is not recommended because it will initialize all programming contents. Q: How to do the hardware initialization? A: Control panel hardware initialization only initializes operator password: 012345 and main operator password: 1234, main operator permission is arm/disarm. There are arming/disarming report and allows bypass. Steps: 1) Power off the control panel and open the cover; 2) Short the restore switch of the control panel with shorting nut or connection cables; 3) Power on the control panel and power off it 10s later; 4) Please remove the shorting nut or connection cable on the restore switch; 5) Cover the control panel well; 6) Recharge the control panel; Q: Why is there no response for keypad operational order but alert sound of error 10s later? A: It may be caused by follow situations: 1) Poor contact of the connection cable between LED keypad and the control panel, please check if the cable is normal; 2) The LED keypad is considered as off-line in the communication. If there is other keypad operates normal, process program command {Main Operator Password} + {*} + {6} + {8} + {#}to restore it or power off the control panel and reboot. Q: How does the control panel detect alternating current, storage battery, control panel tamper-proof and ADSL cable? A: The status of the control panel detection is as follows: 128 Control Panel User Manual 1) 2) 3) 4) The control panel detects AC power supply status once in a while; The control panel detects storage battery status once in a while; The control panel detects tamper-proof status once in a while; The control panel detects ADSL cable status once in a while. Q: The network is disconnected. A: 1) Please check if the network status indicator of the board is normal on; 2) If the network status indicator is not normal on, please check if the network cable connection is normal. Q: What if the client cannot log in the device? A: Troubleshoot according to the prompt. Please check if the device IP Address and Port No. are correct. The device default IP Address is: 192.0.0.64, and the Port No. is: 8000. Please check if the user name and password to log in the control panel are correct. The default user name is: admin, the word is: 12345. Q: Why the control panel cannot communicate with the alarm center group? A: The configuration of control panel communicating with the alarm center group is as follows: 1) If the user communicates with the center via LAN: Configure parameters such as monitoring IP, Port No., User Account and Communication Protocols of the remote alarm center in Remote Configuration-> Others-> Network Center Configuration; 2) If the user communicates via dialing: Configure parameters such as phone number, receiver identity account and communication protocols of the remote alarm center in Remote Configuration-> Others-> Dialing Parameter Setting; 3) If the user communicates via WIFI: Configure APN Name and Parameters of remote alarm center in Remote Configuration-> Others-> WIFI Parameter Setting. The parameters include monitoring IP, Port No., User Account and Communication Protocol, etc.; 4) After setting dialing parameters, LAN parameters and WIFI parameters, configure the uploading mode in Remote Configuration-> Uploading Mode Configuration Q: How to configure the communication way of control panel and alarm center group? A: 1. Center uploading mode supports at most 6 center groups, each center group divides in main channel and 3 backup channels; 2. If the center group is enabled. Enable the center group before the use. 3. For example: The control panel needs to upload report to network alarm center 1 and dialing alarm center1 and network alarm center 1 needs to upload report to network alarm center 2 when it fails to upload it. The configurations are as follows: 1) Enable Group1 and Group2; 2) In the uploading mode configuration list, select N1 in center group 1 main channel, 129 Control Panel User Manual select N2 in backup channel 1, select T1 in Center group2 main channel. 3) Click Apply. If the client is not opened, the user can realize communication with alarm center by programming with keypad. For detailed operations please refer to program command 611~634. Q: Why cannot it upload report and control after WIFI is enabled? A: The follow situations may lead to WIWI connection failure: 1) No SIM Card or poor contact; 2) 3G module antenna is not normally connected or with poor signal; 3) WIFI parameter setting is incorrect; 4) SIM Card has no enough tariffs. 130 Control Panel User Manual Appendix1:Specifications Model Security Control Panel Parameters Network Management External Interface Others DS-19A08/16-BN DS-19A08/16-BNG Alarm Input Alarm Output Siren Power Supply PSTN Supported External Keypads (LCD/LED) Tamper-proof Switch Weekly Schedule Holiday Schedule Partitions Detector Tamper-proof Alarm SMS Alarm-Report Push Arming/Disarming via SMS Command Key Fobs Wireless Network Standard UIM Card Slot SMA Antenna Interface 8/16 Zones Input Local 4-ch + 12-ch expandable, 1A/30VDC 12VDC /750mA Network Application DNS, IPServer, DDNS, and DHCP Network Interface Keypad Bus Port for Storage Battery Printer Interface Power Supply Consumption Working Temperature Working Humidity Installation Mode Dimensions Weight 1 RJ45 10M/100M Self-adaptive 1, RS485 Half-duplex 1 Port, for Storage Battery Accessing 12VDC, 7Ah 1 RS-232 Info. Output Interface AC220V/AC110V ≤5W(Load Power≤40W) -10°C~+55°C 10%~90% Wall-mounting 370×320×86mm < 3.5kg Support 32 1, Support tamper-proof function 8 time segments each day 30 days, 8 time segments each day 8 partitions, one can be set as public partition Support N/A Support N/A Support 32 (Unobstructed Effective Range of 100m) GPRS N/A 131 Control Panel User Manual Appendix2:CID Report CID Code 1103 Description Real-time Zone Alarm CID Code Description 3103 Real-time Zone Alarm Recovery 1110 Fire Zone Alarm 3110 Fire Zone Alarm Recovery 1122 24-hour Non-voiced Zone Alarm 3122 24-hour Non-voiced Zone Alarm Recovery 1123 24-hour Voiced Zone Alarm 3123 24-hour Voiced Zone Alarm Recovery 3131 Perimeter Zone Alarm Recovery 1131 Perimeter Zone Alarm 1132 Internal Delay Zone Alarm 3132 Internal Delay Zone Alarm Recovery 1134 Delay Zone Alarm 3134 Delay Zone Alarm Recovery 1137 Tampering Alarm 3137 Tampering Alarm Recovery 1301 AC Power Down 3301 AC Power Down Recovery 1302 Low Battery 3302 Low Battery Recovery 1305 Control Panel Restoring 1121 Control Panel Duress Alarm 3336 Printer Disconnection Recovery 1336 Printer Disconnection 1354 Phone Line Disconnection 3354 Phone Line Disconnection Recovery 1382 Local Expanded Zone Fault 3382 Local Expanded Zone Recovery 1401 Disarming 3401 Arming 1406 Alarm Clearing Memory Canceling 1810 Soft Zone Emergency Alarm 1570 Zone Bypass 3570 Zone Bypass Recovery 1574 Group Bypass 3574 Group Bypass Recovery 1601 Manual Testing Report 1602 Regular Testing Report 1627 Programming Entering 1628 Programming Exiting 132 Control Panel User Manual CID Code 1910 Description Keypad Disconnection CID Code Description 3910 Keypad Disconnection Recovery 1911 Keypad Bus Relay Disconnection 3911 Keypad Bus Relay Disconnection Recovery 1921 Wireless Network Exception 3921 Wireless Network Recovery 1931 Wired Network Exception 3931 Wired Network Recovery 1930 IP Address Conflict 3930 IP Address Recovery 1931 Network Cable Disconnection 3931 Network Cable Recovery 1940 Motion Detection Enabling 3940 1941 Tampering Alarm Enabling 3941 Tampering Alarm Disabling 1942 Video Loss Alarm Enabling 3942 Video Loss Alarm Disabling 1943 Unmatched Input/ Output Format 3943 Input/ Output Format Recovery 1944 Video Input Exception 3944 Video Input Recovery 1945 HDD Full Alarm 3945 HDD Recovery (For HDD Full) 1946 HDD Fault Alarm 3946 HDD Recovery (For HDD Fault) 3408 Real-time Arming 3441 Stay Arming 133 Motion Detection Disabling Control Panel User Manual Appendix3:LED Keypad Prompt Sound No. Keypad Prompt Sound Description 1 Sound Keypad Prompt, Error Operating Prompt 2 Sound Correctly answered, succeeded 5 Sound Incorrectly answered, report uploading failed in 60s Last for 2s Intermittent Slow Sound, Continuously Intermittent Rapid Sound, Continuously Rapid Beep 3 Long 2 Short report Error Prompt Enter/Exit Delay Enter/Exit Delay, 10s Left Sensor Alarm, Keypad not logged in Keypad Tamper-proof On Appendix4:Conversion Table Conversion Table Hexadecimal Number 134 Corresponding Key *0 *1 *2 *3 *4 *5 uploading Control Panel User Manual Control Panel Command Table 0 0 0 0 0 1 0 0 3 0 0 5 0 0 7 0 0 9 0 1 1 0 1 3 0 1 5 0 1 7 0 1 9 0 2 1 0 2 3 0 2 5 0 2 7 0 2 9 0 3 1 0 3 3 0 3 5 0 3 7 0 3 9 0 4 1 0 4 3 0 4 5 0 4 7 0 4 9 *2 Installer Password 1#Password User Name: 3#Password User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: 5#Password 7#Password 9#Password 11#Password 13#Password 15#Password 17#Password 19#Password 21#Password 23#Password 25#Password 27#Password 29#Password 31#Password 33#Password 35#Password 37#Password 39#Password 41#Password 43#Password 45#Password 47#Password 49#Password 0 0 2 0 0 4 0 0 6 0 0 8 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 2 0 0 2 2 0 2 4 0 2 6 0 2 8 0 3 0 0 3 2 0 3 4 0 3 6 0 3 8 0 4 0 0 4 2 0 4 4 0 4 6 0 4 8 0 5 0 135 2#Password User Name: User Name: 6#PasswordPa ssword User Name: User Name: User Name: User Name: User Name: 16#PasswordP assword User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: 4#Password 8#Password 10#Password 12#Password 14#Password 18#Password 20#Password 22#Password 24#Password 26#Password 28#Password 30#Password 32#Password 34#Password 36#Password 38#Password 40#Password 42#Password 44#Password 46#Password 48#Password 50#Password Control Panel User Manual 0 5 1 0 5 3 0 5 5 0 5 7 0 5 9 0 6 1 0 6 3 0 6 5 0 6 7 0 6 9 0 7 1 0 7 3 0 7 5 0 7 7 0 7 9 0 8 1 0 8 3 0 8 5 0 8 7 0 8 9 0 9 1 0 9 3 0 9 5 0 9 7 0 9 9 51#Password User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: 53#Password 55#Password 57#Password 59#Password 61#Password 63#Password 65#Password 67#Password 69#Password 71#Password 73#Password 75#Password 77#Password 79#Password 81#Password 83#Password 85#Password 87#Password 89#Password 91#Password 93#Password 95#Password 97#Password 99#Password 0 5 2 0 5 4 0 5 6 0 5 8 0 6 0 0 6 2 0 6 4 0 6 6 0 6 8 0 7 0 0 7 2 0 7 4 0 7 6 0 7 8 0 8 0 0 8 2 0 8 4 0 8 6 0 8 8 0 9 0 0 9 2 0 9 4 0 9 6 0 9 8 1 0 0 136 52#Password User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: User Name: 54#Password 56#Password 58#Password 60#Password 62#Password 64#Password 66#Password 68#Password 70#Password 72#Password 74#Password 76#Password 78#Password 80#Password 82#Password 84#Password 86#Password 88#Password 90#Password 92#Password 94#Password 96#Password 98#Password 100#Password User Name: Control Panel User Manual 1 0 1 1 0 3 1 0 5 1 0 7 1 0 9 1 1 1 1 1 3 1 1 5 1 1 7 1 1 9 1 2 1 1 2 3 1 2 5 1 2 7 1 2 9 1 3 1 1 3 3 1 3 5 1 3 7 1 3 9 1 4 1 1 4 3 1 4 5 1 4 7 1 4 9 101#Password User Name: 103#Password User Name: 105#Password User Name: 107#Password User Name: 109#Password User Name: 111#Password User Name: 113#Password User Name: 115#Password User Name: 117#Password User Name: 119#Password User Name: 121#Password User Name: 123#Password User Name: 125#Password User Name: 127#Password User Name: 129#Password User Name: 131#Password User Name: 133#Password User Name: 135#Password User Name: 137#Password User Name: 139#Password User Name: 141#Password User Name: 143#Password User Name: 145#Password User Name: 147#Password User Name: 149#Password User Name: 1 0 2 1 0 4 1 0 6 1 0 8 1 1 0 1 1 2 1 1 4 1 1 6 1 1 8 1 2 0 1 2 2 1 2 4 1 2 6 1 2 8 1 3 0 1 3 2 1 3 4 1 3 6 1 3 8 1 4 0 1 4 2 1 4 4 1 4 6 1 4 8 1 5 0 137 102#Password User Name: 104#Password User Name: 106#Password User Name: 108#Password User Name: 110#Password User Name: 112#Password User Name: 114#Password User Name: 116#Password User Name: 118#Password User Name: 120#Password User Name: 122#Password User Name: 124#Password User Name: 126#Password User Name: 128#Password User Name: 130#Password User Name: 132#Password User Name: 134#Password User Name: 136#Password User Name: 138#Password User Name: 140#Password User Name: 142#Password User Name: 144#Password User Name: 146#Password User Name: 148#Password User Name: 150#Password User Name: Control Panel User Manual 1 5 1 1 5 3 1 5 5 1 5 7 1 5 9 1 6 1 1 6 3 1 6 5 1 6 7 1 6 9 1 7 1 1 7 3 1 7 5 1 7 7 1 7 9 1 8 1 1 8 3 1 8 5 1 8 7 1 8 9 1 9 1 1 9 3 1 9 5 1 9 7 1 9 9 151#Password User Name: 153#Password User Name: 155#Password User Name: 157#Password User Name: 159#Password User Name: 161#Password User Name: 163#Password User Name: 165#Password User Name: 167#Password User Name: 169#Password User Name: 171#Password User Name: 173#Password User Name: 175#Password User Name: 177#Password User Name: 179#Password User Name: 181#Password User Name: 183#Password User Name: 185#Password User Name: 187#Password User Name: 189#Password User Name: 191#Password User Name: 193#Password User Name: 195#Password User Name: 197#Password User Name: 199#Password User Name: 1 5 2 1 5 4 1 5 6 1 5 8 1 6 0 1 6 2 1 6 4 1 6 6 1 6 8 1 7 0 1 7 2 1 7 4 1 7 6 1 7 8 1 8 0 1 8 2 1 8 4 1 8 6 1 8 8 1 9 0 1 9 2 1 9 4 1 9 6 1 9 8 2 0 0 138 152#Password User Name: 154#Password User Name: 156#Password User Name: 158#Password User Name: 160#Password User Name: 162#Password User Name: 164#Password User Name: 166#Password User Name: 168#Password User Name: 170#Password User Name: 172#Password User Name: 174#Password User Name: 176#Password User Name: 178#Password User Name: 180#Password User Name: 182#Password User Name: 184#Password User Name: 186#Password User Name: 188#Password User Name: 190#Password User Name: 192#Password User Name: 194#Password User Name: 196#Password User Name: 198#Password User Name: 200#Password User Name: Control Panel User Manual 2 0 1 2 0 3 2 0 5 2 0 7 2 0 9 2 1 1 2 1 3 2 1 5 Region1 Parameters Configuration 2 0 2 Region3 Parameters Configuration 2 0 4 Region5 Parameters Configuration 2 0 6 Region7 Parameters Configuration 2 0 8 Region9 Parameters Configuration 2 1 0 Region11 Parameters Configuration 2 1 2 Region13 Parameters Configuration 2 1 4 Region15 Parameters Configuration 2 1 6 4 5 7 4 5 8 4 6 0 4 6 1 4 6 2 4 6 3 Region2 Parameters Configuration Region4 Parameters Configuration Region6 Parameters Configuration Region8 Parameters Configuration Region10 Parameters Configuration Region12 Parameters Configuration Region14 Parameters Configuration Region16 Parameters Configuration Communication Control Alarm Center 1 Account Settings 4 5 9 139 Alarm Center 2 Account Settings Alarm Center 1Phone Number Settings Alarm Center 1Phone Number Settings Alarm Center 2Phone Number Settings Alarm Center 2Phone Number Settings Control Panel User Manual 4 6 7 4 6 8 4 6 9 4 7 0 4 7 2 4 7 3 4 7 4 4 7 5 Region Linked Trigger Configuration Enable Trigger Event Linkage Configuration Disable Trigger Event Linkage Configuration 4 7 1 # Trigger Time Settings Host IP Address Settings Host Port Number Settings 4 7 6 4 8 5 4 8 6 4 8 7 4 8 8 4 8 9 4 9 0 4 9 1 4 9 2 4 9 3 Host Time Settings Subnet Mask Settings Gateway Settings Network Center 1 IP Programming # Configuration Address Network Center 1 Port Configuration Programming Address Network Center 1 Protocol and Account Configuration Programming Address Network Center 2 IP # Configuration Programming Address Network Center 2 Port Configuration Programming Address Network Center 2 Protocol and Account Configuration Programming Address Wireless Center 1 IP Configuration Programming Address Wireless Center 1 Port Configuration Programming Address Wireless Center 1 Protocol and Account Configuration Programming Address 140 Siren Settings Control Panel User Manual 4 9 4 4 9 5 4 9 6 Alarm and Bypass Recovery Printing Configuration Host Tamper-proof Configuration 5 3 1 5 3 1 5 3 1 5 6 4 5 0 3 5 0 4 5 1 0 5 1 1 5 1 3 5 6 7 5 6 8 # Configuration Programming 5 0 2 Wireless Center 2 IP Address 5 0 1 Wireless Center 2 Port Configuration Programming Address Wireless Center 2 Protocol and Account Configuration Programming Address 4 9 9 Printer Configuration Device Information Printing Configuration Operation Programming Information Printing Configuration 5 0 0 Device Recovery Information Printing Configuration System Emergency Alarm Linked Siren Configuration Testing Report Configuration System Time and Hostage Report Configuration System Report and Arming/Disarming Prompt Configuration System Key User Permission Configuration Host System Fault Detection Configuration System Fault Display Configuration System Keyboard Fault Prompt Sound Configuration 141 Alarm Information Printing Configuration Control Panel User Manual 6 1 1 6 1 2 6 1 3 6 1 4 6 1 5 6 1 6 6 1 7 6 1 8 6 1 9 6 2 0 6 2 1 6 2 2 6 2 3 6 2 4 6 2 5 6 2 6 Center Group 1 Enabling Configuration Center Group 1 Uploading Mode Configuration Center Group 1 Region Alarm Report Configuration Center Group 1 Non-region Alarm Report Configuration Center Group 2 Uploading Mode Configuration Center Group 2 Region Alarm Report Configuration Center Group 2 Non-region Alarm Report Configuration Center Group 3 Enabling Configuration Center Group 4 Enabling Configuration Center Group 2 Enabling Configuration Center Group 3 Uploading Mode Configuration Center Group 3 Region Alarm Report Configuration Center Group 3 Non-region Alarm Report Configuration Center Group 4 Uploading Mode Configuration Center Group 4 Region Alarm Report Configuration Center Group 4 Non-region Alarm Report Configuration 142 Control Panel User Manual 6 2 7 6 2 8 6 2 9 6 3 0 6 3 1 6 3 2 6 3 3 6 3 4 Center Group 5 Enabling Configuration Center Group 5 Uploading Mode Configuration Center Group 5 Region Alarm Report Configuration Center Group 5 Non-region Alarm Report Configuration Center Group 6 Enabling Configuration Center Group 6 Uploading Mode Configuration Center Group 6 Region Alarm Report Configuration Center Group 6 Non-region Alarm Report Configuration 143 First Choice for Security Professionals
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 145 Language : zh-CN Tagged PDF : Yes Author : Yee Jiang Creator : Microsoft® Word 2010 Create Date : 2016:01:22 11:03:38+08:00 Modify Date : 2016:01:22 11:03:38+08:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools