Hanwha Techwin SSA-S2000V Standalone RFID Access Controller User Manual Appendix6 SSA S200
Samsung Techwin Co Ltd Standalone RFID Access Controller Appendix6 SSA S200
User manual
Standalone RFID Access Controller User Manual SSA-S2000V Standalone RFID Access Controller User Manual Copyright ©2010 Samsung Techwin Co., Ltd. All rights reserved. Trademark is the registered logo of Samsung Techwin Co., Ltd. The name of this product is the registered trademark of Samsung Techwin Co., Ltd. Other trademarks mentioned in this manual are the registered trademark of their respective company. Restriction Samsung Techwin Co., Ltd shall reserve the copyright of this document. Under no circumstances, this document shall be reproduced, distributed or changed, partially or wholly, without formal authorization of Samsung Techwin. Disclaimer Samsung Techwin makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility. Samsung Techwin reserves the right to change the contents of this document without prior notice. Warranty If the product does not operate properly in normal conditions, please let us know. Samsung Techwin will resolve the problem for free of charge. The warranty period is 3 years. However, the followings are excluded: • If the system behaves abnormally because you run a program irrelevant to the system operation. • Deteriorated performance or natural worn-out in process of time • Sensory phenomenon that does not affect the performance or quality of the product (ex : working noise) safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING • To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. WARNING 1. Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause fire, electrical shock, or damage to the product. 2. Incorrectly connecting the power supply or replacing battery may cause explosion, fire, electric shock, or damage to the product. 3. Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fire. 4. Securely plug the power cord into the power receptacle. Insecure connection may cause fire. 5. When installing the controller, fasten it securely and firmly. The fall of controller may cause personal injury. 6. Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers filled with water on top of the controller. Doing so may cause personal injury due to fire, electric shock, or falling objects. 7. Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or electric shock. 8. If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock. 9. If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is not liable for problems caused by unauthorized modifications or attempted repair.) 10.. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock. CAUTION 1. Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive vibration or magnetic interference. 2. Do not install in a location subject to high temperature (over 50°C), low temperature (below -30°C), or high humidity. Doing so may cause fire or electric shock. 3. If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it. 4. Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fire or damage to the product. 5. Keep out of direct sunlight and heat radiation sources. It may cause fire. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time. English _ 3 SAFETY INFORMATION CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. safety information FCC Statement Caution : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, any cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 13. Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus combination to avoid injury from tip-over. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 4_ safety information contents 10 Features What’s included At a Glance Cable Color Scheme INSTALLATION AND EXTERNAL CONNECTION 11 12 12 14 Cable Selection Bypass Diode Connection I/O Connection External Reader Connection INITIALIZATION 15 16 16 Basic Operations Initialization Forced Initialization with External Line READER MODE SETUP 17 18 18 19 Reader Mode Setup (RF ONLY) Reader Mode Setup (RF + P/W) Reader Mode Setup (PIN ONLY) Reader Mode Setup (RF/PIN Combination Mode) Enabling Keypad Input for the Card Number 11 15 17 19 USER MANAGEMENT 20 20 20 21 21 22 BASIC SETUP 23 23 23 24 24 25 25 26 26 27 27 CONTENTS PRODUCT INTRODUCTION To register cards in RF ONLY mode RegIsterIng cards In a combInatIon of RF and P/W modes To regIster cards In PIN mode RegIsterIng cards In RF card / PIN combInatIon mode To delete a regIstered card or PIN number Duress Alarm To specify the retry count for an unregistered ID To specify the keypad input suspension time if the retry count with an unregistered ID exceeds the limit To specify the delayed start time in Secure mode To specify the operation time of the Door Contact Sensor To specify the limited time for the keypad input To specify the alarm output port for the dismantled device To open or close the entry door To set or release the QUICK mode To set or release the Toggle mode for the door relay English _ 5 contents I/O TIME SETUP 28 28 29 29 30 30 31 31 32 To specify the output time if the card is authenticated To specify the output time if the card is not authenticated To specify the Duress TTL output To specify the alarm output for an input error of the Door contact Sensor To specify the alarm operation time for AUX 1 To specify the alarm operation time for AUX 2 To specify the alarm operation time for AUX 3 To activate or deactivate the door relay by the Door Contact Sensor ADVANCED SETTING 33 33 34 34 35 35 36 36 To specify the TTL output operation mode To set the chime bell function To specify the chime bell operation time To specify the input mode for AUX 1 To specify the input mode for AUX 2 To specify the input mode for AUX 3 To specify the input mode for the Exit Button To specify the input mode for the Door Contact Sensor ADDITIONAL FEATURES 37 37 38 39 40 40 Mute To specify the use of the tamper alarm To check the output specified for a registered card user To check the output specified for an unregistered card user To check the output specified for the Door Contact Sensor alarm To check the output specified for AUX 1 To check the output specified for AUX 2 To check the output specified for AUX 3 OTHER INFORMATION 41 42 InItIal Values FunctIon codes TROUBLESHOOTING 44 Troubleshooting PRODUCT SPECIFICATIONS 49 product specifications 33 37 38 39 41 44 49 6_ contents product introduction FEATURES Single Door Access Control You can use the RF card (SSA-C100,SSA-C110,SSA-C120) to control a single door. User Registration You can register a total of 512 cards including the Master Card. Keypad Registration SSA-S2000V is equipped with the built-in keypad that you can use to register, delete cards or configure various settings independently. Buzzer On/Off With the help of various buzzer tones, you can check the operation status and the current settings and results of the product. External I/O Pins SSA-S2000V has 5 input ports and 4 output ports installed (2 relay and 2 TTL outputs). The input ports can receive signals from the Exit button and the Door Contact sensor, while the two relays can be connected to the door lock and the alarm device. One of the TTL output ports can function as a chime bell in connection with the door bell. Duress Alarm This is used in a situation where you should open the door inevitably by a robber insisting to do so. Entering the two-digit button and recognizing the registered card (or card number) can open duress alarm password with pressing the the door normally, while you can set to produce the TTL signal notifying the door is forcibly opened. Limited Access Tries for an Unregistered Card You can specify the limit of times to try accessing the door, and the suspended operation time of the keypad for an improper access. English _ 7 PRODUCT INTRODUCTION This controller is best designed for a single entry door control (single door access control). This product can save up to 512 cards including the master card, with which you can make an effective management (such as adding, deleting or changing the settings) of the cards. Its epoxy adhesion and aluminium case guarantees shock-resistance and stable operation in a challenging environment. This product features 5 external ports that can be connected to the Exit button, Door Contact Sensor, Motion Sensor, and Fire Sensor. It also has 2 relay outputs that can control the door lock and alarm relay. The dual tamper switch triggers an alert if the product is forcibly disassembled. You can use the keypad to configure all settings as necessary. This product is designed for a standalone system. product introduction WHAT’S INCLUDED Check if the following items are included in the product package. SSA-S2000V Main Unit 3.5 x 40mm Screws (x4) 3.5 x 25mm Screws (x4) 6 x 30mm Plastic Anchors (x4) CD Manual tGj Quick Guide 3mm Hex Wrench (x1) 8_ product introduction Diodes (x2) (UF4004, 1N4001~4007) Master Card (x1) AT A GLANCE Front/Rear PRODUCT INTRODUCTION SSA-S2000V System Status LED Indicates the operation status of the system. Keypad Use this to configure or release settings as appropriate, or enter a card number. TAMPER SWITCH A tamper switch to detect falling from the wall. 17-PIN Connector Used to connect to the power source or I/O cable. Buzzer Piezo buzzer. Fixing Hole Fixing hole for wall-mounting. English _ 9 product introduction CABLE COLOR SCHEME Item Cable Color Signal Line Description Red DC +12V Power (+12V) Black GND(-) Earth-grounding for power Blue with white stripes NC(RL1) Door Relay NC Terminal Gray with red stripes COM(RL1) Door Control Relay (COM) Port White with red stripes NO(RL1) Door Relay NO port Purple with white stripes NC(RL2) Alarm Relay (NC) Port White COM(RL2) Alarm Relay (COM) Port Purple NO(RL2) Alarm Relay (NO) Port Orange with white stripes TTL TTL Output Port Brown with white stripes CHI Chime Bell Output Orange EXIT Exit button connection port Yellow with red stripes CONTACT Door Contact Sensor Connection Port Green AUX IN 1 Aux Input #1 Green with white stripes AUX IN 2 Aux Input #2 Green with red stripes AUX IN 3 Aux Input #3 Pink DATA_0 Wiegand Data 0 Input Port Sky blue DATA_1 Wiegand Data 1 Input Port Power Output Input 10_ product introduction installation and external connection CABLE SELECTION INSTALLATION AND EXTERNAL CONNECTION DC12V Power Supply SSA-S2000V RF Reader Item Power (DC12V) DC Power This Product Reader (power and data) External Reader This Product Door Contact Sensor Exit Button Sensor Input Input This Product J Door Lock, Alarm Device Lock (Alarm) This Product Sensor Input Lock/Alarm Cable Type Belden #9409, 18 AWG 2 Conductor, Unshielded Belden #9512, 22 AWG 4 Conductor, Shielded Belden #9514, 22 AWG 8 Conductor, Shielded Belden #9512, 22 AWG 4 Conductor, Shielded Belden #9514, 22 AWG 8 Conductor, Shielded Belden #9409, 18 AWG 2 Conductor, Unshielded The cables should be thick enough to allow the maximum current consumed by the reader. English _ 11 installation and external connection BYPASS DIODE CONNECTION If you connected an inductor (door locks or alarm device) to the output relay, there should occur a voltage surge while the inductor is turning on and off. If you do not connect a reverse diode to the relay, the surge voltage will cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect a reverse diode between the devices. DC+ Cathode 1N4004 ~ 1N4007 or equiv. DCSSA-S2000V Anode Lock/Alarm I/O CONNECTION Input Connection Door Contact Sensor: Green with red stripes, GND Exit Button: Orange line, GND SSA-S2000V Door Contact Sensor BlackRed+ DC + 12V Power Supply Exit Button PUSH 1. Connect the DC 12V(+) of the power supply unit to the red line. 2. Connect the GND(-) of the power supply unit to the black line. - Exit Button Connection 1. Connect one line of the Exit button to the orange line. 2. Connect the other line of the Exit button to GND. - Door Contact Sensor Connection 1. Connect one line of the door contact sensor to the yellow with red stripes. 2. Connect the other line of the door contact sensor to GND. - Auxiliary Input Device Connection (AUX 1 (green), AUX 2 (green with white stripes), AUX 3 (green with red stripes) 1. Connect one line of the external input device to AUX 1, AUX 2, or AUX 3. 2. Connect the other line of the external input device to GND(-). 12_ installation and external connection Output Connection EXIT EXIT INSTALLATION AND EXTERNAL CONNECTION EXIT BUTTON CONTACT DOOR CONTACT AUX IN#1 CHIME +12V GND SSA-S2000V GND DOOR RELAY COM ALARM RELAY COM DOOR RELAY NO Cathode Anode PIR SENSOR ALARM RELAY NO CHIME BELL +12V 1N4004~1N4007 or equiv. GND DC 12V DOOR LOCK SIREN POWER SUPPLY - Door open (POWER FAIL SAFE) when the power is disconnected from the door lock (Door Relay) 1. Connect the relay COM line (gray with red stripes for locking the door) to DC +12V. 2. Connect the relay NC line (blue with white stripes for locking the door) to the plus(+) line of the door lock. 3. Connect the minus (-) line of the door lock to GND (-). - Door close (POWER FAIL SECURE) when the power is disconnected from the door lock (Door Relay) 1. Connect the relay COM line (gray with red stripes for locking the door) to DC +12V. 2. Connect the relay NO line (white with red stripes for locking the door) to the plus (+) line of the door lock. 3. Connect the minus (-) line of the door lock to GND (-). - Alarm Connection (Alarm Relay) 1. Connect the relay COM (white for the alarm device) to DC +12V. 2. Connect the relay NO line (purple for the alarm device) to the plus (+) line of the alarm device. 3. Connect the minus (-) line of the alarm device to GND (-). - Chime Bell Connection (the chime bell operated by TTL-level signal must be installed in advance.) 1. Connect the chime bell line (brown with white stripes) of the controller to DC +5V. 2. Connect the GND line of the power supply unit to GND (-) of the chime bell. 3. Press to a0ctivate EthNeT chime bell. English _ 13 installation and external connection EXTERNAL READER CONNECTION Wiegand DATA0(Pink) Wiegand DATA0(Sky blue) SSA-S2000V BlackRed+ GND DC+12V (+) (-) - Proximity Reader Connection 1. Connect the DC 12V(+) of the power supply unit to the plus (+) line of the reader. 2. Connect the GND(-) line of the power supply unit to the minus (-) line of the reader. 3. Connect the Wiegand data input line 0 of the proximity reader to the purple line. 4. Connect the Wiegand data input line 1 of the proximity reader to the sky blue line. • For a list of compliant readers (external readers), see the followings: - Standard 26bit Wiegand format proximity reader 14_ installation and external connection initialization BASIC OPERATIONS Initial Status While the product is working normally, the orange LED indicator blinks every one second. INITIALIZATION Predefined Operation for a Registered Card When reading a registered card, it opens the door with the melody. t Gj SSA-S2000V Exit Button Operation If you press the Exit button, the door will be opened. EXIT Predefined Operation for an Unregistered Card When reading an unregistered card, it produces an alarm with the melody for two seconds. You can specify the use of the alarm and change the operation time. Secure Mode Operation The person who exits the last can set the secure mode using the keypad. Set Secure mode: Press the button twice and press Release secure mode: Present and authenticate a registered card or the Master Card to the reader. You can use the keypad to specify the delayed start time for the Secure mode. (Refer to the delayed start time in Secure mode on page 24.) For effective security purposes, you can set to activate the sensors (via auxiliary input ports) only in Secure mode. Duress Alarm If you are forced to open the door under a robber’s control, enter the Duress password and press number of your registered card (or PIN). (See page 23.) with the How to use the chime bell When you have connected and set the chime bell, press to ring the chime bell. (See page 33.) English _ 15 initialization INITIALIZATION If you have the Master Card registered, you can use it to initialize the device. 1. Present the Master Card to the device. 2. Press the button twice and press Gj t SSA-S2000V 3. The system will restore the factory default settings with all LED indicators blinking. Initializing the system will lose all data. SSA-S2000V If the product works abnormally, use initialization to restore the default settings. FORCED INITIALIZATION WITH EXTERNAL LINE 1. Turn off the product, shortcircuit between the green line and the orange line with white stripes, and turn it back on. 12V GND Green 2. When the initialization is completed, 3 LED indicators are blinking with a beep. Orange with white stripes SSA-S2000V 3. Restore the connection of the two lines back to their original state. 16_ initialization Connect (Shortcircuit) reader mode setup - You can specify the operation mode for the device. - Once a mode is specified, it will not switch until you perform the initialization. - You must keep the Master Card in safe for later use as it is required for your change to the device settings. - If progression is halted for more than one minute during any of the following processes, the operation mode of the reader will return to the previous state. READER MODE SETUP READER MODE SETUP (RF ONLY) No Master Card or Master PIN is ever registered. If you remember the Master Card or the Master PIN was registered, initialize the product and try again. 1. When you turn on the product, all of the 3 LED indicators will flash with a beep. • No flashing of the 3 indicators denotes that the reader mode is already specified. 2. Press Button and Button in sequence and press When the mode is specified, only the green LED indicator flashes. SSA-S2000V 3. Present a card that you want to register as the Master Card to the device. When the Master Card is registered, only the red LED indicator flashes. 4. Present cards to register with the device one after another, and the device will register them with a beep. If you don’t want to register the cards right now, simply jump to Step 5 above without through Step 4 above. 5. Present the registered Master Card to the product once again. 6. The device enters Standby mode with only the orange LED indicator flashing. Î Î t Gj Gj t Î SSA-S2000V SSA-S2000V SSA-S2000V SSA-S2000V English _ 17 reader mode setup READER MODE SETUP (RF + P/W) No Master Card or Master PIN is ever registered. If you remember the Master Card or the Master PIN was registered, initialize the product and try again. 1. When you turn on the product, all of the 3 LED indicators will flash with a beep. • No flashing of the 3 indicators denotes that the reader mode is already specified. SSA-S2000V 2. Press Button and Button in sequence and press 3. Present a card that you want to register as the Master Card to the device. When the Master Card is registered, only the red LED indicator flashes. 4. Present a card to the device, enter the 4-6 digit password and press If you don’t want to register the cards right now, simply jump to Step 5 above without through Step 4 above. 5. Present the registered Master Card to the product once again. 6. The device enters Standby mode with only the orange LED indicator flashing. Î SSA-S2000V Gj Gj Î SSA-S2000V t t Î SSA-S2000V SSA-S2000V READER MODE SETUP (PIN ONLY) No Master Card or Master PIN is ever registered. If you remember the Master Card or the Master PIN was registered, initialize the product and try again. 1. When you turn on the product, all of the 3 LED indicators will flash with a beep. • No flashing of the 3 indicators denotes that the reader mode is already specified. 2. Press Button and Button in sequence and press When the mode is specified, only the green LED indicator flashes. SSA-S2000V 3. Enter the 4-6 digit Master PIN number and press When the Master PIN is registered, only the red LED indicator flashes. 4. Enter a PIN number to register (4-6 digits) and press Repeat the step above if you want to register PIN numbers with the device in sequence. If you don’t want to register the PIN number right now, simply jump to Step 5 above without through Step 4 above. 5. Enter the 4-6 digit Master PIN number again and press 6. The device enters Standby mode with only the orange LED indicator flashing. 18_ reader mode setup READER MODE SETUP (RF/PIN COMBINATION MODE) No Master Card or Master PIN is ever registered. If you remember the Master Card or the Master PIN was registered, initialize the product and try again. • No flashing of the 3 indicators denotes that the reader mode is already specified. SSA-S2000V 2. Press Button and Button in sequence and press 3. Present a card that you want to register as the Master Card to the device. When the Master Card is registered, only the red LED indicator flashes. 4. Present cards or PIN numbers (4-6 digits) to register with the device one after another, and the device will register them with a beep. If you don’t want to register the cards right now, simply jump to Step 5 above without through Step 4 above. 5. Present the registered Master Card to the product once again. 6. The device enters Standby mode with only the orange LED indicator flashing. or SSA-S2000V Î SSA-S2000V Gj t Gj t Î SSA-S2000V SSA-S2000V ENABLING KEYPAD INPUT FOR THE CARD NUMBER Ensure that you must have registered the Master Card. 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press and You can set the device to allow you to control the door by entering the 8 digit Gj t • Repeat Step 1 above to release the specified mode, press Button Button in sequence, and press SSA-S2000V SSA-S2000V card number using the keypad. The default is “Keypad Input Disabled”. English _ 19 READER MODE SETUP 1. When you turn on the product, all of the 3 LED indicators will flash with a beep. user management TO REGISTER CARDS IN RF ONLY MODE Ensure that you must have registered the Master Card and the device is specified in RF ONLY mode. 1. Present the Master Card to the device. When the mode is specified, only the green LED indicator flashes. Gj t and Button in sequence and press 2. Press Button When the device enters Standby, only the red LED indicator flashes. 3. Present a card to the device, it will be registered with a beep. Repeat this step if you want to register multiple cards. SSA-S2000V 4. Present the Master card to the device again, and the device will switch to normal mode. If no input is made for 20 seconds, the device will switch to normal mode. Î Gj t Î SSA-S2000V SSA-S2000V SSA-S2000V REGISTERING CARDS IN A COMBINATION OF RF AND P/W MODES Ensure that you must have registered the Master Card and the device is specified in RF + P/W mode. 1. Present the Master Card to the device. When the mode is specified, only the green LED indicator flashes. Gj t and Button in sequence and press 2. Press Button When the device enters Standby, only the red LED indicator flashes. SSA-S2000V 3. Present a card to the device, enter the 4-6 digit password and press Repeat this step if you want to register multiple cards. 4. Present the Master card to the device again, and the device will switch to normal mode. If no input is made for 20 seconds, the device will switch to normal mode. 20_ user management Î SSA-S2000V Î SSA-S2000V Gj t Î SSA-S2000V SSA-S2000V TO REGISTER CARDS IN PIN MODE Ensure that you must have registered the Master Card and the device is specified in PIN mode. 1. Enter the Master PIN number and press When the mode is specified, only the green LED indicator flashes. SSA-S2000V 3. If you enter a user number (4-6 digits) to register and press number will be registered with a beep. Repeat this step if you want to register multiple PIN numbers. , the PIN 4. Present the Master PIN number to the device again, and the device will switch to normal mode. If no input is made for 20 seconds, the device will switch to normal mode. Î Î SSA-S2000V SSA-S2000VSSA-S2000V REGISTERING CARDS IN RF CARD / PIN COMBINATION MODE Ensure that you must have registered the Master Card and the device is specified in RF Card / PIN combination mode. 1. Present the Master Card to the device. When the mode is specified, only the green LED indicator flashes. Gj t and Button in sequence and press 2. Press Button When the device enters Standby, only the red LED indicator flashes. SSA-S2000V 3. Present cards or PIN numbers (4-6 digits) to register with the device one after another, and the device will register them with a beep. Repeat this step if you want to register multiple cards or PIN numbers. 4. Present the Master PIN number to the device again, and the device will switch to normal mode. If no input is made for 20 seconds, the device will switch to normal mode. or SSA-S2000V SSA-S2000V Î SSA-S2000V Gj t Î SSA-S2000V The door may be accessed in two ways: using the card or the PIN number. English _ 21 USER MANAGEMENT and Button in sequence and press 2. Press Button When the mode is specified, only the green LED indicator flashes. user management TO DELETE A REGISTERED CARD OR PIN NUMBER Ensure that you must have registered the Master Card or the Master PIN number and the device is specified in a certain mode. This is applicable in all modes. 1. Enter the Master Card or Master PIN. When the mode is specified, only the green LED indicator flashes. Gj t and Button in sequence and press 2. Press Button When the device enters Standby, only the red LED indicator flashes. SSA-S2000V 3. Present a card or PIN number to delete. Repeat this step if you want to register multiple cards or PIN numbers. 4. Present the Master card to the device again, and the device will switch to normal mode. If no input is made for 20 seconds, the device will switch to normal mode. or 22_ user management SSA-S2000V Î SSA-S2000V Gj SSA-S2000V t Î SSA-S2000V basic setup DURESS ALARM If you are forced to open the door under the control of a criminal such as a robber, enter the predefined password with the number of your registered card (or PIN), which outputs the emergency TTL signal. 1. Present the Master Card to the device. and Button in sequence and press Gj t 3. Enter the two-digit Duress code and press • The default code is set to “00”. However, the number “77” can not be used because it is set for the Secure mode. SSA-S2000V SSA-S2000V TO SPECIFY THE RETRY COUNT FOR AN UNREGISTERED ID You can specify the retry count for authentication with an unregistered card or PIN. If the retry count exceeds the set limit, the keypad input will be suspended for the next one minute. (You can specify the keypad input suspension time in “To specify the keypad input suspension time if the retry count with an unregistered ID exceeds the limit” on page 24.) 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t 3. Enter the two-digit retry count and press SSA-S2000V • You can specify a number from 00 to 99. • The retry count for an unregistered ID is defaulted to “05”. SSA-S2000V English _ 23 BASIC SETUP 2. Press Button basic setup TO SPECIFY THE KEYPAD INPUT SUSPENSION TIME IF THE RETRY COUNT WITH AN UNREGISTERED ID EXCEEDS THE LIMIT 1. Present the Master Card to the device. and Button in sequence and press 3. Enter the two-digit keypad input suspension time (unit: minute) and press Gj t 2. Press Button SSA-S2000V • The default is set to “01”. You can specify a time from 01 to 99 minutes. You can specify the time of the keypad input suspension (followed by an alarm) if an unregistered user keeps trying to open the door for certain times (the code number is set to “82”. SSA-S2000V TO SPECIFY THE DELAYED START TIME IN SECURE MODE 1. Present the Master Card to the device. and Button in sequence and press 3. Enter the two-digit delayed start time (unit: minute) and press Gj t 2. Press Button SSA-S2000V • The default is set to “00”. SSA-S2000V See the table below for your reference. Secure Mode When the last person set the Secure mode before exiting the office, the external sensors will get activated since then. Delayed Start If the external sensors get activated right after you set the Secure mode, your motion will be detected before you can get out of the secure area, which will trigger the alarm. Thus, it is recommended to set the Secure mode to get activated after a certain time. Enter the delayed start time by the minute; the sensor operation in Secure mode must have been specified in advance. (Refer to “Alarm Operation Time for Auxiliary Input” on pages 30-31) 24_ basic setup TO SPECIFY THE OPERATION TIME OF THE DOOR CONTACT SENSOR The Door Contact sensor detects the opening of the door. If the door is forcibly opened by an unregistered user, the Door Contact Sensor will perform the predefined alarm operation after the set time. (For setting the alarm operation time, refer to the alarm output for an input error of the Door Contact Sensor on page 30.) BASIC SETUP 1. Present the Master Card to the device. and Button 3. Enter the two-digit operation time (unit: second) and press Gj t in sequence and press 2. Press Button SSA-S2000V • The default is set to “00” second, which means the Door Contact Sensor is disabled. • You can specify from 01 to 99. SSA-S2000V TO SPECIFY THE LIMITED TIME FOR THE KEYPAD INPUT When it passes a certain time during your setting using the keypad , all your settings will be ignored and return to the initial state. Specify the delay time between the input of the last key and restoring the previous state. 1. Present the Master Card to the device. and Button 3. Enter the two-digit operation time (unit: second) and press • The default is set to “20” second. You can specify from 10 to 99. Gj t in sequence and press 2. Press Button SSA-S2000V SSA-S2000V English _ 25 basic setup TO SPECIFY THE ALARM OUTPUT PORT FOR THE DISMANTLED DEVICE Specify the alarm type for the dismantled device. The alarm rings from the dismantlement of the device to the authentication of the Master Card or a registered card. 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press • The default is set to “02” (alarm). For the alarm output port settings, refer to the output port table on page 28. Gj t 3. Provide the alarm output port and press SSA-S2000V • The alarm for the dismantled device occurs regardless of the operation mode of either Normal or Secure so you simply specify the operation port only. (To specify the operation port, refer to the operation port settings in the output port setting table on page 28.) SSA-S2000V TO OPEN OR CLOSE THE ENTRY DOOR Follow the step below If you want to keep the door open regardless of the authentication process using the Master Card or PIN. 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t • To release opening the door, repeat Step 1 above, select the > buttons and press SSA-S2000V SSA-S2000V 26_ basic setup TO SET OR RELEASE THE QUICK MODE The QUICK mode is applicable to RF ONLY mode (01) and PIN ONLY mode (03) and RF/PIN combination mode (05), which enables you to open the door by simply pressing without the need of the PIN number. (This is useful for the normal business hours when the door entries and exits occur frequently.) BASIC SETUP 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press > buttons and press Gj t • To release the QUICK mode, repeat Step 1 above, select the SSA-S2000V • The default is set to “not used”. SSA-S2000V TO SET OR RELEASE THE TOGGLE MODE FOR THE DOOR RELAY In the Toggle mode, the door opens if it is closed or vice versa by presenting a registered card or entering the PIN. 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t • To release the Toggle mode, repeat Step 1 above, select the > buttons and press SSA-S2000V • The default is set to “not used”. SSA-S2000V English _ 27 I/O time setup ❖ Output Port Setting Table You must specify the port settings using whatever combination of the followings if you want the device to operate in Secure mode or normal + Secure mode. Port Setting Value Example EX 1) If only the door relay operates in normal and Secure modes Operation mode setting value Operate only in Secure mode 00 Operate in normal mode and Secure mode 50 Normal and Secure modes: 50 Door Relay: +01 Output Port Setting Value: 51 Operation port setting value Operate the door relay only 01 Operate the alarm relay only 02 EX 2) If the alarm relay and the TTL output operate in Secure mode Operate the TTL output only 04 Secure Mode: 00 Operate the door relay and TTL output 05 Operate the alarm relay and TTL output 06 Alarm Relay, TTL: +06 Output Port Setting Value: 06 TO SPECIFY THE OUTPUT TIME IF THE CARD IS AUTHENTICATED You can specify the output time if the card ID is authenticated. When the card ID is authenticated, the door relay and the TTL output operate for a set time. 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press 4. Specify the two-digit TTL output time and press Gj t 3. Enter the two-digit door open time and press SSA-S2000V • For instance, if you set the door open time to “03” and TTL to “00”, the door relay operates for 3 seconds for an authenticated card ID. • By default, the door relay operates for “03” seconds while the TTL output works for “00” second in normal and Secure modes. • You can specify from 00 to 99. SSA-S2000V 28_ I/O time setup TO SPECIFY THE OUTPUT TIME IF THE CARD IS NOT AUTHENTICATED You can specify the output time if an unregistered card or PIN number fails in getting authenticated. 1. Present the Master Card to the device. twice and press • If you want the alarm relay alone to operate in normal and Secure modes for an unauthenticated card, select the < > buttons and press 4. Enter the two-digit door relay output time and press 5. Enter the two-digit alarm relay output time and press 6. Enter the two-digit TTL output time and press Gj t 3. Refer to the output port table on page 28 and specify a desired output mode. SSA-S2000V • You can specify a two-digit time from 00 to 99 seconds. By default, only the alarm relay operates for “02” seconds in normal and Secure modes. SSA-S2000V Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate. TO SPECIFY THE DURESS TTL OUTPUT If you enter the Duress code and present a registered card, the TTL output operates. Specify the TTL operation time for this purpose. (For the Duress code, refer to Duress Alarm on page 23.) 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press • The default is set to “03” second. You can specify a time from 00 to 99 seconds. Gj t 3. Specify the two-digit TTL output time (unit: second) and press SSA-S2000V SSA-S2000V English _ 29 I/O TIME SETUP 2. Press Button I/O time setup TO SPECIFY THE ALARM OUTPUT FOR AN INPUT ERROR OF THE DOOR CONTACT SENSOR You can specify the output port and operation time if an error occurs from the Door Contact Sensor. You must have specified the operation time of the Door Contact Sensor. (Refer to “To specify the operation time of the Door Contact Sensor” on page 25.) 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press • If you want the alarm relay alone to operate in normal and Secure modes in case of an error from the Door contact Sensor, select the < buttons and press 4. Enter the two-digit door relay output time and press SSA-S2000V 5. Enter the two-digit alarm relay output time and press 6. Enter the two-digit TTL relay output time and press Gj t 3. Refer to the output port table on page 28 and specify a desired output mode. SSA-S2000V • You can specify a two-digit time from 00 to 99 seconds. • By default, all output times are set to “00”. Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate. TO SPECIFY THE ALARM OPERATION TIME FOR AUX 1 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press 4. Enter the two-digit door relay output time and press SSA-S2000V 5. Enter the two-digit alarm relay output time and press 6. Enter the two-digit TTL relay output time and press Gj t 3. Refer to the output port table on page 28 and specify a desired output mode. • If you want the alarm relay alone to operate in normal and Secure modes in case of an input through the auxiliary port, select the < > buttons and press SSA-S2000V • You can specify a two-digit time from 00 to 99 seconds. • By default, all output times are set to “00”. Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate. 30_ I/O time setup TO SPECIFY THE ALARM OPERATION TIME FOR AUX 2 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press 5. Enter the two-digit alarm relay output time and press SSA-S2000V • You can specify a two-digit time from 00 to 99 seconds. • By default, all output times are set to “00”. Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate. TO SPECIFY THE ALARM OPERATION TIME FOR AUX 3 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press • If you want the alarm relay alone to operate in normal and Secure modes in case of an input through the auxiliary port, select the < > buttons and press 4. Enter the two-digit door relay output time and press SSA-S2000V 5. Enter the two-digit alarm relay output time and press 6. Enter the two-digit TTL relay output time and press Gj t 3. Refer to the output port table on page 28 and specify a desired output mode. SSA-S2000V • You can specify a two-digit time from 00 to 99 seconds. • By default, all output times are set to “00”. Other output ports that are not specified for the output mode will not be activated. For instance, if you set the output mode to [5][2] and assign the operation time for each output device by following the steps 4, 5, and 6 above, only the alarm relay will operate. English _ 31 I/O TIME SETUP SSA-S2000V 4. Enter the two-digit door relay output time and press 6. Enter the two-digit TTL relay output time and press Gj t 3. Refer to the output port table on page 28 and specify a desired output mode. • If you want the alarm relay alone to operate in normal and Secure modes in case of an input through the auxiliary port, select the > buttons and press I/O time setup TO ACTIVATE OR DEACTIVATE THE DOOR RELAY BY THE DOOR CONTACT SENSOR You can set the Door Contact Sensor to control the door lock. This is to allow the Door Contact Sensor to control the door relay where the sensor keeps the door relay active from the normal opening of the door to its closing. This is useful when the door stays open with just one authentication. 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t • To release the control by the Door contact Sensor, repeat Step 1 above, select the < > buttons and press SSA-S2000V The default is set to “disabled”. SSA-S2000V 32_ I/O time setup advanced setting TO SPECIFY THE TTL OUTPUT OPERATION MODE This is to switch the TTL output from LOW (0V) to HIGH (5V) when it is activated. 1. Present the Master Card to the device. in sequence and press • To release the setting, repeat Step 1 above, select the > buttons and press SSA-S2000V The default is set to “switch from HIGH(5V) to LOW(0V)”. SSA-S2000V TO SET THE CHIME BELL FUNCTION You can specify the use of the chime bell. Use the chime bell in the TTL level (5V) for this purpose. The default output time is 5 seconds. For changing the output time, refer to “To specify the chime bell operation time” on page 34. 1. Present the Master Card to the device. 2. Press Button twice and press > buttons and press Gj t • To release the setting, press the < SSA-S2000V The default is set to “use the chime bell”. SSA-S2000V English _ 33 ADVANCED SETTING and Button Gj t 2. Press Button advanced setting TO SPECIFY THE CHIME BELL OPERATION TIME You can specify the chime bell operation time. 1. Present the Master Card to the device. and Button in sequence and press Gj t 2. Press Button SSA-S2000V 3. Specify the two-digit operation time (unit: second) and press The default is set to “05” second. You can specify a time from 00 to 99 seconds. SSA-S2000V TO SPECIFY THE INPUT MODE FOR AUX 1 You can specify an operation for the auxiliary port 1 when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t • To release the setting, repeat Step 1 above, select the > buttons and press SSA-S2000V The default is set to “switch from HIGH(5V) to LOW(0V)”. SSA-S2000V 34_ advanced setting TO SPECIFY THE INPUT MODE FOR AUX 2 You can specify an operation for the auxiliary port 2 when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. and Button in sequence and press > buttons and press Gj t • To release the setting, press the < SSA-S2000V The default is set to “switch from HIGH(5V) to LOW(0V)”. SSA-S2000V TO SPECIFY THE INPUT MODE FOR AUX 3 You can specify an operation for the auxiliary port 3 when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t • To release the setting, repeat Step 1 above, select the > buttons and press SSA-S2000V The default is set to “switch from HIGH(5V) to LOW(0V)”. SSA-S2000V English _ 35 ADVANCED SETTING 2. Press Button advanced setting TO SPECIFY THE INPUT MODE FOR THE EXIT BUTTON You can specify an operation for the Exit button when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. 2. Press Button and Button and Button > buttons and press Gj t • To release the setting, press the < SSA-S2000V The default is set to “switch from HIGH(5V) to LOW(0V)”. SSA-S2000V TO SPECIFY THE INPUT MODE FOR THE DOOR CONTACT SENSOR You can specify an operation for the Door Contact Sensor when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t • To release the setting, repeat Step 1 above, select the > buttons and press SSA-S2000V The default is set to “switch from HIGH(5V) to LOW(0V)”. SSA-S2000V 36_ advanced setting additional features MUTE You can mute the keypad tone or melody in normal operation. 1. Present the Master Card to the device. and Button in sequence and press Gj t • To release the setting, repeat Step 1 above, select the > buttons and press SSA-S2000V By default, it is set to “enabled”. SSA-S2000V TO SPECIFY THE USE OF THE TAMPER ALARM You can maintain the alarm setup in normal operation and release it in case of a service repair requiring the dismantlement of the device. You must set the alarm mode when you have installed the device.For the alarm output port settings, refer to “To specify the alarm output port for the dismantled device” on page 26. 1. Present the Master Card to the device. 2. Press Button twice and press Gj t • To release the alarm setting for the dismantled device, repeat Step 1 above, select the < > buttons and press SSA-S2000V The default is set to “disabled”. You can release the alarm for the dismantled device by presenting the Master SSA-S2000V Card or a registered card. English _ 37 ADDITIONAL FEATURES 2. Press Button additional features TO CHECK THE OUTPUT SPECIFIED FOR A REGISTERED CARD USER You can check the output setting that you specified in “To specify the output time if the card is authenticated”. (See page 28.) 1. Present the Master Card to the device. and Button in sequence and press Gj t 2. Press Button SSA-S2000V SSA-S2000V TO CHECK THE OUTPUT SPECIFIED FOR AN UNREGISTERED CARD USER You can check the output setting that you specified in “To specify the output time if the card is not authenticated”. (See page 29.) 1. Present the Master Card to the device. 2. Press Button and Button and Button Gj t SSA-S2000V SSA-S2000V 38_ additional features TO CHECK THE OUTPUT SPECIFIED FOR THE DOOR CONTACT SENSOR ALARM You can check the output setting that you specified in “To specify the alarm output for an input error of the Door contact Sensor”. (See page 30.) and Button in sequence and press Gj t 2. Press Button SSA-S2000V SSA-S2000V TO CHECK THE OUTPUT SPECIFIED FOR AUX 1 You can check the output setting that you specified in “To specify the alarm operation time for AUX 1”. (See page 30.) 1. Present the Master Card to the device. and Button in sequence and press Gj t 2. Press Button SSA-S2000V SSA-S2000V English _ 39 ADDITIONAL FEATURES 1. Present the Master Card to the device. additional features TO CHECK THE OUTPUT SPECIFIED FOR AUX 2 You can check the output setting that you specified in “To specify the alarm operation time for AUX 2”. (See page 31.) 1. Present the Master Card to the device. and Button in sequence and press Gj t 2. Press Button SSA-S2000V SSA-S2000V TO CHECK THE OUTPUT SPECIFIED FOR AUX 3 You can check the output setting that you specified in “To specify the alarm operation time for AUX 3”. (See page 31.) 1. Present the Master Card to the device. 2. Press Button and Button in sequence and press Gj t SSA-S2000V SSA-S2000V 40_ additional features other information INITIAL VALUES This product operates in the following initial values: For changing the settings or registering/deleting the user card, refer to the applicable section in this document. 1) Entry permitted for a registered card - The door control relay operates for 3 seconds. OTHER INFORMATION - The green LED indicator flashes for 3 seconds. 2) Entry denied for an unregistered card - The alarm relay operates for 2 seconds. - The red LED indicator flashes for 2 seconds. 3) Duress Mode Password : 00 The TTL output port produces a signal for 3 seconds in Duress mode. 4) QUICK MODE : Disabled 5) Chime Bell Output : Enabled Chime Bell Operating Time : 0.5 second 6) Melody Sound : Enabled 7) Keypad Input Limited Use : 20 seconds 8) When an input signal is sensed : ‘H’ ‘L’ (common for all inputs) 9) When a TTL output signal is sensed : ‘H L’ 10) Patrol Mode Delay Time : 00 minute 11) Door Sensor Sensing Time : 00 second 12) Retry count for an unauthenticated entry : 05 times 13) Alarm for Dismantled Device : Disabled Dismantled device Alarm Output Port : 02 (Alarm Relay) 14) Toggle Mode : Disabled 15) Control Lock by the Door Sensor : Disabled English _ 41 other information FUNCTION CODES NO. Code Number 11 Additional user card registration (RF CARD ONLY MODE) 12 Additional user card and PIN registration (RF CARD + PIN MODE) 13 Additional PIN registration (PIN ONLY MODE) 14 Delete a registered card or PIN number 15 Additional user card or PIN registration (RF/PIN combination mode) 21 To specify the output time if the card is authenticated 22 To specify the output time if the card is not authenticated 24 Set the Door Contact Sensor alarming time 25 Set the AUX 1 alarming time 10 26 Set the AUX 2 alarming time 11 27 Set the AUX 3 alarming time 12 29 Set the Duress Mode password (2 digits) 13 30 Set the TTL output time in Duress Mode 14 31 To check the output of the registered card user (test on code 21) 15 32 To check the output of the unregistered card user 16 34 To check the output specified specified for the Door Contact Sensor alarm 17 35 To check the output specified specified for AUX 1 18 36 To check the output specified specified for AUX 2 19 37 To check the output specified specified for AUX 3 20 39 Set the chime bell ringing time 21 41 Set the door open 22 42 Release the door opening 23 43 Set the QUICK Mode 24 44 Release the QUICK Mode 25 45 Toggle to control the door relay 26 46 Release the toggling to control the door relay 27 47 Set to control the door relay using the Door Contact Sensor 28 48 Release the control of the door relay using the Door Contact Sensor 42_ other information Function Item Code Number Function Item 29 51 Turn off the sound 30 52 Turn on the sound 31 60 To specify the keypad input suspension time if the retry count with an unregistered ID exceeds the limit 32 61 Sense if AUX 1 switches from L to H 33 62 Sense if AUX 1 switches from H to L 34 63 Sense if AUX 2 switches from L to H 35 64 Sense if AUX 2 switches from H to L 36 65 Sense if AUX 3 switches from L to H 37 66 Sense if AUX 3 switches from H to L 38 67 Sense if the Exit button switches from L to H 39 68 Sense if the Exit button switches from H to L 40 69 Sense if the Door Contact Sensor switches from L to H 41 70 Sense if the Door Contact Sensor switches from H to L 42 71 Set the TTL output to H 43 72 Set the TTL output to L 44 73 Keypad input enabled 45 74 Keypad input disabled 46 77 Chime bell enabled 47 78 Chime bell disabled 48 80 Set the starting delay time for Patrol Mode 49 81 Set the operation time for the Door Contact Sensor 50 82 To specify the retry count for an unregistered ID 51 83 Set the limitation time for the keypad input 52 84 Set the alarm output port for the dismantled device 53 88 Dismantled device alarm enabled 54 89 Dismantled device alarm disabled 55 99 System Initialization (all settings deleted) English _ 43 OTHER INFORMATION NO. troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. PROBLEM ACTION When I turn on the product, it does not recognize the card with just the 3 LED indicators blinking. Check if the product is installed properly and works normally. - In the initial setup of the product or after it is initialized Set the operation mode and register the Master card and user cards as usual because the product is in the initial state. c SSA-S2000V modes available : Mode Number + ENT √ RF Only : 01 + ENT √ RF + P/W : 02 + ENT √ PIN Only : 03 + ENT √ RF or PIN : 05 + ENT d Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) e Enter the user card or PIN number and provide the password according to the mode f Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ For more information about registering the Master Card and the user card, refer to the initial setup section in the user manual. 2) If this happens while the product is operating normally (with the Master Card and user card registered) Product malfunction c Power: OFF ON d If the problem persists, perform the initialization process for the next step. √ For more information about initializing the product, refer to the initialization section in the user manual. 3) If the problem persists after you have followed the procedures above, contact a designated service center. The product just switches to normal operation mode while I am registering a user in a set mode or configure the settings. 1) 44_ troubleshooting 1) If no key input is entered within 20 seconds in a set mode, the product will switch to normal operation mode automatically. (normal operation) PROBLEM I can not register an additional user card (or PIN). ACTION 1) English _ 45 TROUBLESHOOTING Check if the product is installed properly and works normally. - In the initial setup of the product or after it is initialized Set the operation mode and register the Master card and user cards as usual because the product is in the initial state. c SSA-S2000V modes available : Mode Number + ENT √ RF Only : 01 + ENT √ RF + P/W : 02 + ENT √ PIN Only : 03 + ENT √ RF or PIN : 05 + ENT d Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) e Enter the user card or PIN number and provide the password according to the mode f Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ For more information about registering the Master Card and the user card, refer to the initial setup section in the user manual. 2) If this happens when you try to register an additional card in normal operation mode - Register the user card only as the Master Card is already registered. c Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) d Command for an additional card registration according to the operation mode √ RF Only : 11 + ENT √ RF + P/W : 12 + ENT √ PIN Only : 13 + ENT √ RF or PIN : 15 + ENT e Enter the user card or PIN number and provide the password according to the mode f Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ For more information about registering the user card, refer to the additional user registration section in the user manual. 3) If the problem persists after you have followed the procedures above, contact a designated service center. troubleshooting PROBLEM ACTION The user card (or PIN) is not deleted. Check the operation status of the product 1) Check if the product works properly. - If the product operates normally (and you have the Master Card or the PIN number) c If you have the card to delete √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ Enter the command to delete the user: 14 + ENT √ Enter another card to delete (if you have multiple cards to delete) √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) d If you have lost the card to delete. But you know the card number √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ Enter the command to enable the keypad input: 73 + ENT √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ Enter the command to delete the user: 14 + ENT √ Enter another card to delete and press ENT (if you have multiple cards to delete) √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ For more information about deleting the user card, refer to the user deletion section in the user manual. - If you have lost the Master Card (or PIN) c Registering or deleting the user card is not possible without the Master Card d Initializing the product √ For more information about initializing the product, refer to the initialization section in the user manual. 2) If the problem persists after you have followed the procedures above, contact a designated service center. I lost the Master Card and could not register or delete the card or change the settings. 1) 46_ troubleshooting You must initialize the product if you want to change the device settings without the Master Card (or PIN). (Initializing the product will restore all your settings regarding the Master Card and user cards to the factory default.) c Initialization using the external cable √ Turn off the product and detach it from the wall. √ Connect the orange line of the product to the orange line with the white stripes. √ Turn on the product and check the initial state (LED indicators blink with the increasing bell sound) √ Disconnect the two short-circuited lines and turn off the product 2) If the problem persists after you have followed the procedures above, contact a designated service center. PROBLEM ACTION SSA-S2000V can recognize a presented RF card but can not recognize the RF card number using the keypad. Check if the buzzer sounds when you press a key. - If you hear the buzzer sound c Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) d Enter the command to enable the keypad input: 73 + ENT e For more information, refer to the section of enabling or disabling the keypad input for a card number in the user manual. - If you hear the buzzer sound after a certain time c The keypad input will be suspended for one minute (default) if you enter unregistered numbers in 5 consecutive times (default). d To change the retry count for an unauthenticated access √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ Enter the command to set the retry count for an unauthenticated access 82 + ENT √ Enter a new retry count: two digits + ENT (ex. 10 + ENT the retry count is 10.) √ For more information, refer to the retry count setting section in the user manual. e To change the keypad suspension time √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ Enter the command to change the keypad suspension time: 60 + ENT √ Enter a new time: two digits + ENT (ex. 10 + ENT the keypad input will be suspended for 10 minutes.) √ For more information, refer to the applicable section for the keypad suspension in the user manual. - If the buzzer stays inactive c Initialize the product. Initializing the product will restore all your settings regarding the Master Card and user cards to the factory default. 2) If the problem persists after you have followed the procedures above, contact a designated service center. The Exit button does not work at all. 1) 1) English _ 47 TROUBLESHOOTING Check if the Exit button is connected to SSA-S2000V properly. - Ensure that the Exit button is of the NO type. 2) Check if the Exit button works normally. - Check the connection cable between the Exit button and SSA-S2000V for any disconnection or short-circuit. - Try to connect the two lines on the Exit button. c If SSA-S2000V responds when you press the Exit button √ Replace the Exit button it is defective d If SSA-S2000V does not respond at all √ Initialize the product the product malfunctions or is damaged. (Initializing will restore all data settings to the default.) √ For more information, refer to the initialization section in the user manual. 3) If the problem persists after you have followed the procedures above, contact a designated service center. troubleshooting PROBLEM The external reader can the RF card but the RF card data will not be transferred to SSA-S2000V or irrelevant data is transferred. ACTION 1) 2) Check if the external reader is connected to SSA-S2000V properly. Check if the external reader works normally. - Check the connection cable between the external reader and SSA-S2000V for any disconnection or short-circuit. - Check if there occurs a noise on the connection cable between the external reader and SSA-S2000V. c If you have to use a measuring device such as an oscilloscope or a multimeter, please consult with a qualified technician. d Measure the Wiegand communication cable and check if the exit reader works properly. : Check the Wiegand output state of the external reader by referring to the user manual, and replace the reader if it shows an abnormal output. e If there occurs a noise on the Wiegand communication cable using the measuring device : Reinforce the GND line by using the shield line and space line as additional GND points. : Extend the Wiegand communication range along with the stable signal reception using the repeater f For more information, refer to the external reader connection section in the user manual. The door lock does not operate at all. 3) If the problem persists after you have followed the procedures above, contact a designated service center. 1) Check if the door lock is connected to SSA-S2000V properly. The connection method may differ depending on the type and operation mode (NO, NC) of the door lock. 2) Check the status of the door lock - Check the connection cable between the door lock and SSA-S2000V for any disconnection or short-circuit. - Check if the door lock works normally. c If you have to use a measuring device such as an oscilloscope or a multimeter, please consult with a qualified technician. d Remove the door lock from SSA-S2000V, and check the relay output of SSA-S2000V: Replace the door lock if the relay output of SSA-S2000V shows a normal state. e For more information, refer to the door lock connection section in the user manual. 3) 48_ troubleshooting If the problem persists after you have followed the procedures above, contact a designated service center. product specifications PRODUCT SPECIFICATIONS Item SSA-S2000V 512 Users Power / Current DC 12V / Max.180mA Reader Port External Reder Port 1ea : 26bit Wiegand for Exit Reading Time (Card) 30ms Door Open Time 00~99 Sec. (Default 3Sec.) Input Port 5ea : Exit Button, Door Sensor, Aux#1, #2, #3 2ea : 2 Form-C Relay Output (COM, NO, NC) / DC12~18V, Rating Max.2A Output Port 1ea : Chime Bell Output / DC5V, Rating Max.500mA 1ea : TTL Output / DC5V, Rating Max.20mA LED Indicator 3 LED Indicators (Red, Green and Orange) Beeper Piezo Buzzer Keypad 12 Key Touch Keypad with Back Lighting Operating Temperature -30°C to +50°C Operating Humidity 10% to 90% relative humidity non-condensing Color / Material Silver with Black/ Polycarbonate & Aluminum Die casting Dimension (W x H x D(mm)) 87.0 x 109.0 x 25.0 Weight 440g ±10 Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal. Correct disposal of batteries in this product (Applicable in the European Union and other European countries with separate battery return systems.) This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm to human health or the environment. To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through your local, free battery return system. English _ 49 PRODUCT SPECIFICATIONS User SALES NETWORK SAMSUNG TECHWIN CO., LTD. Samsungtechwin R&D Center, 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea, 463-400 TEL : +82-70-7147-8740~60 FAX : +82-31-8018-3745 SAMSUNG TECHWIN AMERICA Inc. 1480 Charles Willard St, Carson, CA 90746, UNITED STATES Tol Free : +1-877-213-1222 FAX : +1-310-632-2195 www.samsungcctvusa.com www.samsungsecurity.com www.samsungtechwin.com SAMSUNG TECHWIN EUROPE LTD. Samsung House, 1000 Hillswood Drive, Hillswood Business Park Chertsey, Surrey, UNITED KINGDOM KT16 OPS TEL : +44-1932-45-5300 FAX : +44-1932-45-5325 P/No. : Z8100239101A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2010:10:07 18:12:41-07:00 Modify Date : 2010:10:07 18:12:41-07:00 Page Count : 50 Creation Date : 2010:10:08 01:12:41Z Mod Date : 2010:10:08 01:12:41Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : ltsai Metadata Date : 2010:10:08 01:12:41Z Creator : ltsai Title : Appendix6. User manual_SSA-S200.PDFEXIF Metadata provided by EXIF.tools