Harbor Freight 13500 Peak 11000 Running Watts 22 Hp 670Cc Gas Generator Epa Iii Product Manual
2015-05-27
: Harbor-Freight Harbor-Freight-13500-Peak-11000-Running-Watts-22-Hp-670Cc-Gas-Generator-Epa-Iii-Product-Manual-723824 harbor-freight-13500-peak-11000-running-watts-22-hp-670cc-gas-generator-epa-iii-product-manual-723824 harbor-freight pdf
Open the PDF directly: View PDF .
Page Count: 32
Download | |
Open PDF In Browser | View PDF |
Owner’s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference. REV 15a 13,500 WATT PORTABLE GENERATOR 11,000 RUNNING WATTS 13,500 PEAK WATTS Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors, and vents. ITEM 61725 Visit our website at: http://www.harborfreight.com Email our technical support at: productsupport@harborfreight.com Email our engine support at: predator@harborfreight.com When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible. Copyright© 2013 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included. Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. Table of Contents Specifications.............................................. 2 Safety��������������������������������������������������������� 3 Setup........................................................... 8 Operationr��������������������������������������������������� 16 Maintenances���������������������������������������������� 20 Troubleshooting.......................................... 24 Warranties.................................................. 26 Parts Lists and Diagrams........................... 28 Specifications Generator Output 120/240VAC, 60Hz, 1 Phase 11,000W Rated 13,500W Maximum Receptacles See Figure A: Control Panel on page 8 Displacement Engine Type Cooling System Type Fuel Capacity Type SAE Engine Oil Capacity Run Time @ 50% Load with full tank Sound Level at 3 feet Bore x Stroke Compression Ratio Rotation viewed from PTO (power takeoff - the output shaft) Spark Plug Valve Clearance Speed 670cc Horizontal Dual Cylinder 4-stroke Forced air cooled 87+ octane stabilizer treated unleaded gasoline 7 Gallon 10W-30 above 32° F 5W30 at 32° F or below SJ class oil 2 Quart 7.5 hr. 78 dB 78 mm x 70 mm 7.93:1 Counterclockwise Type NGK® BP-6ES NHSP® / Torch® F6TC Gap Intake Exhaust Idle 0.7 - 0.8 mm 0.10 - 0.15 mm 0.15 - 0.20 mm 1800 RPM The emissions control system for this Engine is warranted for standards set by the U.S. Environmental Protection Agency. For warranty information, refer to the last pages of this manual. Page 2 For technical questions, please call 1-888-866-5797. ITEM 61725 WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Safety Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Addresses practices not related to personal injury. RPM HP Property or Statement Revolutions Per Minute Horsepower WARNING marking concerning Risk of Eye Injury. Wear ANSI-approved safety goggles with side shields. Read the manual before set-up and/or use. WARNING marking concerning Risk of Hearing Loss. Wear hearing protection. Symbol Property or Statement WARNING marking concerning Risk of Respiratory Injury. Operate engine OUTSIDE and far away from windows, doors, and vents. WARNING marking concerning Risk of Fire while handling fuel. Do not smoke while handling fuel. WARNING marking concerning Risk of Fire. Do not refuel while operating. Keep flammable objects away from engine. IMPORTANT SAFETY INSTRUCTIONS Operation Symbol Setup Symbol Definitions WARNING! Read all instructions. Failure to follow all instructions listed below may result in fire, serious injury and/or DEATH. The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. ITEM 61725 For technical questions, please call 1-888-866-5797. Maintenance SAVE THESE INSTRUCTIONS Page 3 Set up Precautions 1. Gasoline fuel and fumes are flammable, and potentially explosive. Use proper fuel storage and handling procedures. Do not store fuel or other flammable materials nearby. Safety 2. Have multiple ABC class fire extinguishers nearby. 3. Operation of this equipment may create sparks that can start fires around dry vegetation. A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements. 4. Set up and use only on a flat, level, well‑ventilated surface. 5. All connections and conduits from the Generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. 6. Connections for standby power to a building electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. 7. Wear ANSI-approved safety goggles, heavy-duty work gloves, and dust mask/respirator during set up. 8. Use only lubricants and fuel recommended in the Specifications chart of this manual. 9. Improper connections to a building electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and the generator may explode, burn, or cause fires when utility power is restored. Consult the utility company and a qualified electrician if intending to use the generator for back up power. Setup 10. Do not operate the Generator before grounding. The Generator must be earth-grounded in accordance with all relevant electrical codes and standards before operation. Operation Maintenance Page 4 For technical questions, please call 1-888-866-5797. ITEM 61725 Operating Precautions 13. Avoid substantially overloading which will trip the circuit breaker. Slightly overloading the generator may not trip the circuit breaker, but will lead to premature generator failure. 14. Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground. 2. Never use a generator indoors, including in garages, basements, crawl spaces and sheds. Opening doors and windows or using fans will NOT prevent carbon monoxide build up in the home. 3. When using generators, keep them outdoors and far away from open doors, windows, and vents to avoid toxic levels of carbon monoxide from building up indoors. 4. If you start to feel sick, dizzy, or weak while using a generator, get to fresh air right away. The carbon monoxide from generators can quickly lead to full incapacitation and death. 5. Keep children away from the equipment, especially while it is operating. 6. Keep all spectators at least six feet from the Engine during operation. 7. Fire Hazard! Do not fill fuel tank while engine is running. Do not operate if gasoline has been spilled. Clean spilled gasoline before starting engine. Do not operate near pilot light or open flame. 8. Do not touch engine during use. Let engine cool down after use. 9. Never store fuel or other flammable materials near the engine. 10. If the plugged in product operates abnormally or unusually slow, immediately stop using the generator as a power source. Read and adhere to the instruction manual of the product to be powered to make sure that it can be safely and efficiently powered by a portable generator. ITEM 61725 Setup 15. Do not touch electrically energized parts of the Generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object. Only use OUTSIDE and far away from windows, doors, and vents. Safety 12. Do not exceed the maximum power rating of the generator. Make sure that the total electrical rating of the all of the tools or appliances plugged into the generator at the same time does not exceed that of the generator. Check that the startup surge will not be beyond the limit of the Generator. 16. Connect the Generator only to a load that is compatible with the electrical characteristics and rated capacities of the Generator. 17. Insulate all connections and disconnected wires. 18. Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. 19. Only use a suitable means of transport and lifting devices with sufficient weight bearing capacity when transporting the generator. 20. Secure the generator on transport vehicles to prevent it from rolling, slipping, and tilting. 21. Industrial applications must follow OSHA requirements. 22. Do not leave the generator unattended when it is running. Turn off the generator (and remove safety keys, if available) before leaving the work area. Operation NEVER use inside a home or garage, EVEN IF doors and windows are open. 11. Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. 23. The generator can produce high noise levels. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Wear ear protection when operating the generator or when working nearby while it is operating. 24. Wear ANSI-approved safety glasses and hearing protection during use. 25. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to a heart pacemaker could cause pacemaker interference or pacemaker failure. Caution is necessary when near the engine’s magneto or recoil starter. For technical questions, please call 1-888-866-5797. Page 5 Maintenance CARBON MONOXIDE HAZARD Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. 1. Operating Precautions (cont.) Safety 26. Use only accessories that are recommended by Harbor Freight Tools for your model. Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment. 27. Do not operate in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Gasoline-powered engines may ignite the dust or fumes. 28. Stay alert, watch what you are doing and use common sense when operating this generator. Do not use while tired or under the influence of drugs, alcohol or medication. 29. Dress properly. Do not wear loose clothing or jewelry. Keep hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts. Setup 30. Parts, especially exhaust system components, get very hot during use. Stay clear of hot parts. 31. Do not cover the generator during operation. 32. Keep the generator and surrounding area clean at all times. 33. Use the equipment, accessories, etc., in accordance with these instructions and in the manner intended for the particular type of equipment, taking into account the working conditions and the work to be performed. Use of the equipment for operations different from those intended could result in a hazardous situation. 34. Do not operate the equipment with known leaks in the engine’s fuel system. 35. WARNING: This product contains or, when used, produces a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code § 25249.5, et seq.) 36. When spills of fuel or oil occur, they must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state, or federal codes and regulations. Store oil rags in a bottom-ventilated, covered, metal container. 37. Keep hands and feet away from moving parts. Do not reach over or across equipment while operating. 38. Before use, check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the equipment’s operation. If damaged, have the equipment serviced before using. Many accidents are caused by poorly maintained equipment. 39. Use the correct equipment for the application. Do not modify the equipment and do not use the equipment for a purpose for which it is not intended. Operation Maintenance Page 6 For technical questions, please call 1-888-866-5797. ITEM 61725 a. Unplug all devices from the generator. b. Turn the engine switch to its “OFF” position. c. Allow the engine to completely cool. d. Then, remove the spark plug cap from the spark plug. 2. Keep all safety guards in place and in proper working order. Safety guards include muffler, air cleaner, mechanical guards, and heat shields, among other guards. 3. Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. 4. Do not alter or adjust any part of the equipment or its engine that is sealed by the manufacturer or distributor. Only a qualified service technician may adjust parts that may increase or decrease governed engine speed. 5. Wear ANSI-approved safety goggles, heavy‑duty work gloves, and dust mask/respirator during service. 6. Maintain labels and nameplates on the equipment. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement. 7. Have the equipment serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the equipment is maintained. Do not attempt any service or maintenance procedures not explained in this manual or any procedures that you are uncertain about your ability to perform safely or correctly. 8. Store equipment out of the reach of children. 9. Follow scheduled engine and equipment maintenance. Refueling: 1. Do not smoke, or allow sparks, flames, or other sources of ignition around the equipment, especially when refuelling. 2. Do not refill the fuel tank while the engine is running or hot. 3. Do not fill fuel tank to the top. Leave a little room for the fuel to expand as needed. 4. Refuel in a well-ventilated area only. 5. Wipe up any spilled fuel and allow excess to evaporate before starting engine. To prevent FIRE, do not start the engine while the smell of fuel hangs in the air. Maintenance Operation SAVE THESE INSTRUCTIONS. Setup 1. Before service, maintenance, or cleaning: Safety Service Precautions ITEM 61725 For technical questions, please call 1-888-866-5797. Page 7 Set Up Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Safety TO PREVENT SERIOUS INJURY: Operate only with proper spark arrestor installed. Operation of this equipment may create sparks that can start fires around dry vegetation. A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements. Components and Controls 120/240VAC 46A Breakers Switch Setup Display Low Oil Indicator 12VDC Receptacle and Breaker Choke Knob Operation Maintenance 120VAC 20A Receptacles and Breaker Page 8 120VAC 20A Receptacles and Breaker 120/240VAC 30A Receptacle and Breakers 120VAC 30A Receptacle and Breaker Figure A: Control Panel Ground Terminal 120/240VAC 46A Receptacle For technical questions, please call 1-888-866-5797. ITEM 61725 Handle Spark Plug (1 of 2) Safety Fuel Cap Battery (sold separately) Setup Control Panel Figure B: Generator Front Air Cleaner Fuel Valve Operation Lifting Bracket Muffler Oil Fill Plug Dipstick Maintenance Spark Plug (2 of 2) Figure C: Generator Back ITEM 61725 For technical questions, please call 1-888-866-5797. Page 9 High Altitude Operation Above 3000 feet WARNING! TO PREVENT SERIOUS INJURY FROM FIRE: Follow instructions in a well-ventilated area away from ignition sources. If the engine is hot from use, shut the engine off and wait for it to cool before proceeding. Do not smoke. Safety NOTICE: Warranty void if necessary adjustments are not made for high altitude use. At high altitudes, the engine’s carburetor, governor, and any other parts that control the fuel-air ratio will need to be adjusted by a qualified mechanic to allow efficient high-altitude use and to prevent damage to the engine and any other devices used with this product. The fuel system on this engine may be influenced by operation at higher altitudes. Proper operation can be ensured by installing an altitude kit at altitudes higher than 3000 ft. above sea level. At elevations above 8000 ft, the engine may experience decreased performance, even with the proper main jet. Operating this engine without the proper altitude kit installed may increase the engine’s emissions and decrease fuel economy and performance. The kit should be installed by a qualified mechanic. High Altitude Kit Parts List - A Setup Part A1 A2 A3 Description Left Main Jet 3000-6000 ft. Right Main Jet 3000-6000 ft. Left Main Jet 6000-8000 ft. Qty 1 1 1 Part Description A4 Right Main Jet 6000-8000 ft. 137d Outer Bowl O-ring (replacement) 137e Inner Bowl O-ring (replacement) Qty 1 1 1 Disassembly 1. Turn off the engine. 4. Remove the Air Cleaner Front Cover (101), pulling it up then out. See Figure E. 2. Close the fuel valve. Air Cleaner Front Cover (101) 3. Remove the Air Cleaner Top Knob (142a) and the two Air Cleaner Front Knobs (102). See Figure D. Air Cleaner Top Knob (142a) Air Cleaner Front Knob (102) Operation Figure E: Remove Front Cover Maintenance Figure D: Remove Knobs Page 10 For technical questions, please call 1-888-866-5797. ITEM 61725 Air Cleaner Top Cover (142b) 9. Remove the four Shroud Nuts (99) and the two Flange Shoulder Bolts (112) from the Shroud (100). The Flange Shoulder Bolt on the right holds the Lifting Bracket (111) in place. See Figure H. Flange Shoulder Bolt (112) Flange Shoulder Bolt (112) behind Lifting Bracket Air Cleaner Spacer (142c) Safety 5. Remove the Air Cleaner Top Cover (142b) and internal Air Cleaner components (Spacer, Foam and Paper Filters (142c-142e)). See Figure F. Foam Air Filter (142d) Setup Paper Air Filter (142e) Shroud Nuts (99) Figure F: Remove Air Cleaner Top Cover and components 6. Remove the two Intake Cover Bolts (143) and the two Air Cleaner Base Bolts (146). See Figure G. Note: Air Cleaner Front Cover is still shown, although it should have been removed in step 4. Shroud (100) Figure H: Remove Shroud 10. Remove the Shroud. Intake Cover Bolts (143) Operation 7. Detach the top of the Fuel Filter Clip (147) from the Air Cleaner Base (142g). Air Cleaner Base Bolts (146) Fuel Filter Clip (147) Maintenance Air Cleaner Base (142g) Figure G: Remove Bolts and Clip from Air Cleaner Base 8. Remove the Air Cleaner Base. ITEM 61725 For technical questions, please call 1-888-866-5797. Page 11 11. WARNING! TO PREVENT SERIOUS INJURY FROM FIRE, BEFORE CONTINUING: a. Make sure that the work area is well‑ventilated and that there are no ignition sources. b. Have multiple class ABC fire extinguishers available. c. Double-check that fuel hose leading from fuel tank to Fuel Filter is clamped or fuel valve is closed. Safety d. Use a safe, proper means to clean up all fuel spills immediately. 12. Squeeze the Spring Clamp (140) and slide it back. Detach the Fuel Hose (141) from the port at the top of the Carburetor. See Figure I. Spring Clamp (140) 15. Disconnect the Throttle Rod Spring from the Throttle Rod Clip. 16. Squeeze the Spring Wire Clamp (32) and slide it back. Detach the Breather Hose (33) from the right side of the Carburetor. See Figure L. Spring Wire Clamp (32) Fuel Hose (141) fuel port Breather Hose (33) Setup Figure I: Detach Fuel Hose 13. Locate the Throttle Rod (174) connection on the left side of the carburetor. See Figure J. Throttle Rod (174) Operation Throttle Rod Spring (175) Figure L: Detach Breather Hose 17. Locate the Choke Rod (177) connection on the right side of the carburetor. See Figure M. Choke Rod Clip (176) Throttle Rod Clip (139) Choke Rod (177) Figure J: Disconnect Throttle Rod Maintenance 14. A: Swing the black Throttle Rod Clip (139) down to release the Throttle Rod. See Figure K. B: Pull the Throttle Rod out of the Clip. Figure M: Disconnect Choke Rod 18. Swing the black Choke Rod Clip (176) aside to release the Choke Rod. Disconnect the Choke Rod. B A Figure K: Throttle Rod Clip Page 12 For technical questions, please call 1-888-866-5797. ITEM 61725 20. Underneath where the Fuel Pump Bracket was, the Solenoid Valve (138) is connected. Note the location of the green wire and green dot on the connector. Unplug the connector. See Figure O. Carburetor Intake Elbow (131) Fuel Pump Bracket (40) Bolt (132) Bolt (133) Bolt (132) Safety 19. At the front of the Carburetor, remove the Bolt (38) holding the Fuel Pump Bracket (40) in place. See Figure N. Bolt (38) Figure N: Remove Fuel Pump Bracket Solenoid wire connector Figure O: Disconnect Solenoid Valve wire connector Setup Note location of dots here. 21. Remove Bolt (133) and two Bolts (132) from the Carburetor Intake Elbow (131). See Figure O. Maintenance Operation 22. Remove the Carburetor assembly from the engine. Keep it upright, it may contain fuel. ITEM 61725 For technical questions, please call 1-888-866-5797. Page 13 23. Hold the fuel drain port over a bowl, and open the Carburetor Drain Plug (137a) to allow fuel to drain out of that port. Once the carburetor is empty, close the Carburetor Drain Plug. See Figure P. 26. Use a carburetor screwdriver (sold separately) to remove the Left Main Jet and replace it with the proper replacement Left Main Jet (A1 or A3) for the altitude. See Figure R. Safety 27. Use a carburetor screwdriver to remove the Right Main Jet and replace it with the replacement Right Main Jet (A2 or A4) for the same altitude as the Left Main Jet. See Figure R. fuel drain port Carburetor Drain Plug (137a) Right Main Jet (A2/A4) Left Main Jet (A1/A3) Figure P: Carburetor Drain 24. Turn the Carburetor assembly over. Setup 25. Remove the four Carburetor Bowl Bolts (137b) and remove the Carburetor Bowl (137c). See Figure Q. Carburetor Bowl Bolt (137b) Carburetor Bowl Bolt (137b) Operation Note: Since carburetor is upside-down, left and right sides are reversed. Figure R: Main Jets Carburetor Bowl (137c) Carburetor Bowl Bolt (137b) Carburetor Bowl Bolt (137b) Figure Q: Carburetor Bowl Bolts Maintenance Page 14 For technical questions, please call 1-888-866-5797. ITEM 61725 Reassembly 1. Replace the Outer and Inner Bowl O-rings (137d, 137e) with the replacements from the altitude kit. Do not reuse existing O-rings. 5. Attach the Choke Rod on the right side of the Carburetor, and secure it with its Clip. [#17,18] 6. Attach the Breather Hose to the Carburetor, and secure it with its Clamp. [#16] 7. Attach the Throttle Rod Spring to the Throttle Rod Clip on the left side of the Carburetor. [#15] Inner Bowl O-ring 8. Insert the Throttle Rod on the left side of the Carburetor, and secure it with its Clip. [#14] Safety Note: Reassembly step references shown in brackets. 9. Attach the Fuel Hose to the port at the top of the Carburetor and attach it using its Clamp. [#12] Outer Bowl O-ring 10. Install Shroud using four Shroud Bolts and two Flange Shoulder Bolts. [#9,10] Include the Lifting Bracket in place on the right Flange Shoulder Bolt. 2. Assemble the Carburetor Bowl using four Carburetor Bowl Bolts. [#25] Assemble Carburetor Intake Elbow to Intake using Bolts. [#21] 3. Attach Solenoid Valve connector, line up green wire with the green dot on the connector. [#20] 4. Attach Fuel Pump Bracket to front of intake using Bolt. Gently lift the Bracket after assembly to ensure proper alignment. [#19] 13. Replace the Air Cleaner Front Cover. [#4] 14. Use the Air Cleaner Top Knob and Air Cleaner Front Knobs to secure the Covers in place. [#3] 15. Once all connections are secure, open fuel valve. 16. Wipe up any spilled fuel and allow excess to evaporate before starting engine. To prevent FIRE, do not start the engine while the smell of fuel hangs in the air. Operation Figure S: Replace Bowl O-rings 12. Place the Paper Air Filter, Foam Air Filter, Air Cleaner Spacer, and Air Cleaner Top Cover into place on the Air Cleaner Base. [#5] Battery Setup Instructions 1. Place a fully charged, lead-acid 12 volt, 36 Ah battery (not included) in a stable, flat location near the engine. 4. Attach the negative cable securely to the negative battery terminal to prevent disconnection and short circuits. 2. Use provided battery cables only. 5. Coat the terminals and cable ends with a corrosion-preventive coating. 3. Attach the positive cable securely to the positive battery terminal to prevent disconnection and short circuits. Grounding 1. The Generator must be properly grounded in accordance with all relevant electrical codes and standards before operation. Have the unit grounded by a qualified electrician if you are not qualified to do so. 2. To ground the Generator, connect a #XX AWG grounding wire (not included) from the Grounding Terminal on the Control Panel to a grounding rod (not included). The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the Generator. 3. Refer to local regulations for ground source information. ITEM 61725 For technical questions, please call 1-888-866-5797. Page 15 Maintenance Carburetor Bowl Setup 11. Install Air Cleaner Base using two Air Cleaner Base Bolts. Connect Fuel Filter Clip under left side of Air Cleaner Base. Install the Intake Cover and Intake Screen using the Intake Cover Bolts. [#6-8] Operation Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Safety Pre-Start Checks Inspect engine and equipment looking for damaged, loose, and missing parts before set up and starting. If any problems are found, do not use equipment until fixed properly. Checking and Filling Engine Oil Setup NOTICE: Your Warranty is VOID if the engine’s crankcase is not properly filled with oil before each use. Before each use, check the oil level. Do not run the engine with low or no engine oil. Running the engine with no or low engine oil WILL permanently damage the engine. Oil Fill Cap (yellow) Dipstick 1. Make sure the engine is stopped and is level. 2. Close the Fuel Valve. 3. On the back of the Generator, pull the Dipstick out, and wipe its end off with a clean, lint free rag. 4. Reinsert the Dipstick fully and remove it to check the oil level. The oil level should be up to the full level as shown in Figure U. 5. If the oil level is at or below the low mark: Operation a. Clean the top of the yellow Oil Fill Cap and the area around it. Figure T: Oil Fill Cap and Dipstick (on back of Generator) b. Remove the Oil Fill Cap by turning it counterclockwise. c. Add the appropriate type of oil until the oil level is at the proper level. SAE 10W‑30 oil is recommended for general use. (Table A: SAE Viscosity Grades on page 21 in the Maintenance section shows other viscosities to use in different average temperatures.) Dipstick 6. Thread the Oil Fill Cap back in and reinsert the Dipstick. NOTICE: Do not run the engine with too little oil. The engine will be permanently damaged. Full Level Maintenance Figure U: Oil Fill Level Page 16 For technical questions, please call 1-888-866-5797. Engine Crankcase ITEM 61725 WARNING! TO PREVENT SERIOUS INJURY FROM FIRE: Fill the fuel tank in a well-ventilated area away from ignition sources. If the engine is hot from use, shut the engine off and wait for it to cool before adding fuel. Do not smoke. 1. Clean the Fuel Cap and the area around it. 2. Unscrew and remove the Fuel Cap. Note: Do not use gasoline that has been stored in a metal fuel container or a dirty fuel container. It can cause particles to enter the carburetor, effecting engine performance and/or causing damage. 4. Then replace the Fuel Cap. 5. Wipe up any spilled fuel and allow excess to evaporate before starting engine. To prevent FIRE, do not start the engine while the smell of fuel hangs in the air. Maintenance Operation Setup 3. If needed, fill the Fuel Tank to about 1 inch under the fill neck of the Fuel Tank with 87 octane or higher unleaded gasoline that has been treated with a fuel stabilizer additive. Follow fuel stabilizer manufacturer’s recommendations for use. Note: Do not use gasoline containing more than 10% ethanol (E10). Do not use E85 ethanol. Safety Checking and Filling Fuel ITEM 61725 For technical questions, please call 1-888-866-5797. Page 17 Starting the Engine Safety Before starting the engine: a. Inspect the generator and engine. b. Disconnect all electrical loads from the generator. c. Fill the engine with the proper amount and type of both unleaded gasoline and oil. 1. To start a cold engine, pull the START Knob out to the START position. To restart a warm engine, push the START Knob in to the RUN position. 1 Setup 2. Open the Fuel Valve. 2 OFF ON ON 3. Turn the Engine Switch to START. OFF START Operation 4. Allow the Engine to run for several seconds. Then, if the START lever is in the START position, move the START Lever very slowly to its RUN position. Note: Moving the START Lever too fast could stall the engine. 3 4 Maintenance IMPORTANT: Allow the engine to run at no load for five minutes with no load after each start‑up so that the engine can stabilize. 5. Adjust the Throttle as needed. Break-in Period: a. Breaking-in the engine will help to ensure proper equipment and engine operation. b. The break‑in period will last about 25 hours of use. DO NOT exceed 75% of the Generator’s rated capacity during this period. • Change the engine oil after this period. Under normal operating conditions subsequent maintenance follows the schedule explained in the Maintenance section. Page 18 For technical questions, please call 1-888-866-5797. ITEM 61725 Wattage Estimates 1. The total combined load through the outlet on the Generator must not exceed the rated maximum power of the unit. Wattages listed below are estimates for that type of equipment only. Check nameplate wattages on all loads before connecting to Generator. This Unit Can Power Any Running Start-up 2. Reduce the load if the AC Circuit Breaker turns off. One of the Following Items: Watts Watts Once the load is reduced, press the Circuit Breaker 600 900 Button to reset the Generator and continue operation. 1/4 HP Air Compressor 1/6 HP Motor 500 800 3/8" Drill 400 600 Calculate Power Draw: Mini Refrigerator 400 700 Table/Box Fan 200 Power draw can be calculated by multiplying volts 15 Amp Battery Charger 380 and amps. The resulting number is wattage. String Trimmer 350 • Never exceed the rated maximum wattage for Hedge Trimmer 500 the Generator or any outlet amperage rating. Radio 50 Ten 75 Watt Light Bulbs 750 • Refer to appliance/tool owner’s manuals to determine the wattage of electrical load devices. 3. Allow the Engine to run at no load for five minutes • Long power cords and extension cords draw after each start‑up to allow the Engine to stabilize. additional power. Keep cord length at a minimum. Setup Load and Circuit Breaker: Safety Connecting Loads to the Generator Figure V: Plug Load In 4. Plug the power cord of the 120 volt appliance/ tool into the 120 volt AC Outlet on the Generator. Note: Do not allow the generator to completely run out of fuel with devices attached. A generator’s output may sharply spike as it runs out of fuel, causing damage to attached devices. Operation Stopping the Engine 1. To stop the engine in an emergency, turn the Engine Switch off. 2. Under normal conditions, use the following procedure: Maintenance a. Remove all electrical load devices from the Generator. b. Turn the Engine Switch off. c. Close the Fuel Valve. NOTICE See Long-Term Storage on page 23 for complete storage instructions. ITEM 61725 For technical questions, please call 1-888-866-5797. Page 19 Maintenance WARNING Safety TO PREVENT SERIOUS INJURY FROM ACCIDENTAL STARTING: Turn the Power Switch of the equipment to its “OFF” position, wait for the engine to cool, and disconnect the spark plug cap before performing any inspection, maintenance, or cleaning procedures. TO PREVENT SERIOUS INJURY FROM EQUIPMENT FAILURE: Do not use damaged equipment. If abnormal noise, vibration, or excess smoking occurs, have the problem corrected before further use. Follow all service instructions in this manual. The engine may fail critically if not serviced properly. Many maintenance procedures, including any not detailed in this manual, will need to be performed by a qualified technician for safety. If you have any doubts about your ability to safely service the equipment or engine, have a qualified technician service the equipment instead. Cleaning, Maintenance, and Lubrication Schedule Setup Note: This maintenance schedule is intended solely as a general guide. If performance decreases or if equipment operates unusually, check systems immediately. The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle, temperature, air quality, fuel quality, and other factors. Note: The following procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the engine and equipment. Before Each Use Procedure Monthly or Every 3 mo. or Every 6 mo. or every 20 50 hr. of use 100 hr. of use hr. of use Yearly or every 300 hr. of use Every 2 Years Brush off outside of engine Check engine oil level Check air cleaner Check sediment cup Change engine oil Operation * Clean air filter Check and clean spark plug 1. Check/adjust idle speed 2. Check/adjust valve clearance 3. Clean fuel tank, strainer and carburetor ** 4. Clean carbon build-up from combustion chamber Replace fuel line if necessary ** ** *Service more frequently when used in dusty areas. **These items should be serviced by a qualified technician. Maintenance Page 20 For technical questions, please call 1-888-866-5797. ITEM 61725 WARNING! TO PREVENT SERIOUS INJURY FROM FIRE: Fill the fuel tank in a well-ventilated area away from ignition sources. If the engine is hot from use, shut the engine off and wait for it to cool before adding fuel. Do not smoke. 7. Reinsert the Dipstick fully and remove it to check the oil level. The oil level should be up to the full level as shown in Figure X. Dipstick 1. Clean the Fuel Cap and the area around it. 2. Unscrew and remove the Fuel Cap. 3. Remove the Strainer and remove any dirt and debris. Then replace the Strainer. Note: Do not use gasoline that has been stored in a metal fuel container or a dirty fuel container. It can cause particles to enter the carburetor, affecting engine performance and/or causing damage. Full Level 4. If needed, fill the Fuel Tank to about 1 inch under the fill neck of the Fuel Tank with 87 octane or higher unleaded gasoline that has been treated with a fuel stabilizer additive. Follow fuel stabilizer manufacturer’s recommendations for use. 8. If the oil level is at or below the low mark: 5. Then replace the Fuel Cap. 6. Wipe up any spilled fuel and allow excess to evaporate before starting engine. To prevent FIRE, do not start the engine while the smell of fuel hangs in the air. Engine Oil Change Setup Figure X: Oil Fill Level Engine Crankcase a. Clean the top of the yellow Oil Fill Cap and the area around it. b. Remove the Oil Fill Cap by turning it counterclockwise. c. Add the appropriate type of oil until the oil level is at the proper level. SAE 10W‑30 oil is recommended for general use. The SAE Viscosity Grade chart shows other viscosities to use in different average temperatures. CAUTION! Oil is very hot during operation and can cause burns. Wait for engine to cool before changing oil. 30 Operation Note: Do not use gasoline containing more than 10% ethanol (E10). Do not use E85 ethanol. Add fuel stabilizer to the gasoline or the Warranty is VOID. 1. Make sure the engine is stopped and is level. 2. Close the Fuel Valve. 10W-30 3. Place a drain pan (not included) underneath the crankcase’s drain plug. 4. Remove the drain plug and allow the oil to drain out. Recycle used oil. 5. Replace the drain plug and tighten it. Safety Checking and Filling Fuel 5W-30 -20 0 20 40 60 80 Average outdoor temperature 100°F Table A: SAE Viscosity Grades Dipstick 9. Thread the Oil Fill Cap back in and reinsert the Dipstick. NOTICE: Do not run the engine with too little oil. The engine will be permanently damaged. Figure W: Oil Fill Cap and Dipstick (on back of Generator) 6. On the back of the Generator, pull the Dipstick out, and wipe its end off with a clean, lint free rag. ITEM 61725 For technical questions, please call 1-888-866-5797. Page 21 Maintenance Oil Fill Cap (yellow) Air Filter Maintenance Spark plug Maintenance 1. Remove the Air Cleaner Cover and the air filters and check for dirt. Clean as described below. 1. Disconnect spark plug caps from end of plugs. Clean out debris from around spark plugs. 2. Cleaning: 2. Using a spark plug wrench, remove the spark plugs. Safety • For paper filters: To prevent injury from dust and debris, wear ANSI-approved safety goggles, NIOSH‑approved dust mask/respirator, and heavy-duty work gloves. In a well‑ventilated area away from bystanders, use pressurized air to blow dust out of the filter. • For foam filters: Wash the filter in warm water and mild detergent several times. Rinse. Squeeze out excess water and allow it to dry completely. Soak the filter in lightweight oil briefly, then squeeze out the excess oil. 3. Install the cleaned filters. Secure the Air Cleaner Cover before use. 3. Inspect the spark plugs: If the electrode is oily, clean it using a clean, dry rag. If the electrode has deposits on it, polish it using emery paper. If the white insulator is cracked or chipped, the spark plug needs to be replaced. Recommended Spark Plugs NGK® NHSP® / TORCH® BP-6ES F6TC NOTICE: Using an incorrect spark plug may damage the engine. Setup 4. When installing a new spark plug, adjust the plug’s gap to the specification on the Specifications chart. Do not pry against the electrode, the spark plug can be damaged. 5. Install the new spark plugs or the cleaned spark plugs into the engine. • Gasket-style: Finger-tighten until the gasket contacts the cylinder head, then tighten about 1/2-2/3 turn more. • Non-gasket-style: Finger-tighten until the plug contacts the cylinder head, then tighten about 1/16 turn more. Operation NOTICE: Tighten the spark plugs properly. If loose, the spark plugs will cause the engine to overheat. If overtightened, the threads in the engine block will be damaged. 6. Apply dielectric spark plug boot protector (not included) to the end of the spark plugs and reattach the wires securely. Maintenance Page 22 For technical questions, please call 1-888-866-5797. ITEM 61725 When the equipment is to remain idle for longer than 20 days, prepare the engine for storage as follows: c. Replace spark plug, but leave spark plug cap disconnected. 1. CLEANING: Wait for engine to cool, then clean engine with dry cloth. NOTICE: Do not clean using water. The water will gradually enter the engine and cause rust damage. Apply a thin coat of rust preventive oil to all metal parts. d. Pull Starter Handle to distribute oil in cylinder. Stop after one or two revolutions when you feel the piston start the compression stroke (when you start to feel resistance). To protect the fuel tank during storage, fill the tank with gasoline that has been treated with a fuel stabilizer additive. Follow fuel stabilizer manufacturer’s recommendations for use. Refer to Checking and Filling Fuel on page 23. WARNING! TO PREVENT SERIOUS INJURY FROM FIRE: Fill tank in a well-ventilated area away from ignition sources. If the engine is hot from use, shut the engine off and wait for it to cool before adding fuel. Do not smoke. 3. LUBRICATION: a. Change engine oil. NOTICE: During extended storage periods the Engine must be started every 3 months and allowed to run for 15 – 20 minutes or the Warranty is VOID. 6. AFTER STORAGE: Before starting the engine during or after storage, keep in mind that untreated gasoline will deteriorate quickly. Drain the fuel tank and change to fresh fuel if untreated gasoline has been sitting for a month, if treated gasoline has been sitting beyond the fuel stabilizer’s recommended time period, or if the engine does not start. Maintenance Operation b. Clean out area around spark plug. Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole. 5. STORAGE AREA: Cover and store in a dry, level, well-ventilated area out of reach of children. Storage area should also be away from ignition sources, such as water heaters, clothes dryers, and furnaces. Setup 2. FUEL: 4. BATTERY: Disconnect battery cables (if equipped). Recharge batteries monthly while in storage. Safety Long-Term Storage ITEM 61725 For technical questions, please call 1-888-866-5797. Page 23 Troubleshooting Problem Possible Causes Engine will not start FUEL RELATED: Probable Solutions FUEL RELATED: Safety Setup Operation Maintenance 1. No fuel in tank or fuel valve closed. 1. Fill fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline and open fuel valve. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 2. START not in START position, cold engine. 2. Move START to START position. 3. Gasoline with more than 10% ethanol used. (E15, E20, E85, etc.) 3. Clean out ethanol rich gasoline from fuel system. Replace components damaged by ethanol. Use fresh 87+ octane stabilizertreated unleaded gasoline only. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 4. Low quality or deteriorated, old gasoline. 4. Use fresh 87+ octane stabilizer-treated unleaded gasoline. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 5. Carburetor not primed. 5. Pull on Starter Handle to prime. 6. Dirty fuel passageways. 6. Clean out passageways using fuel additive. Heavy deposits may require further cleaning. 7. Carburetor needle stuck. Fuel can be smelled in the air. 7. Gently tap side of carburetor float chamber with screwdriver handle. 8. Too much fuel in chamber. This can be caused by the carburetor needle sticking. 8. Turn START to RUN position. Remove spark plug and pull the start handle several times to air out the chamber. Reinstall spark plug and set START to START position. 9. Clogged Fuel Filter. 9. Replace Fuel Filter. IGNITION (SPARK) RELATED: IGNITION (SPARK) RELATED: 1. Spark plug cap not connected securely. 1. Connect spark plug cap properly. 2. Spark plug electrode wet or dirty. 2. Clean spark plug. 3. Incorrect spark plug gap. 3. Correct spark plug gap. 4. Spark plug cap broken. 4. Replace spark plug cap. 5. Circuit breaker tripped. 5. Reset circuit breaker. Check wiring and starter motor if breaker continues to trip. 6. Incorrect spark timing or faulty ignition system. 6. Have qualified technician diagnose/ repair ignition system. COMPRESSION RELATED: COMPRESSION RELATED: 1. Cylinder not lubricated. Problem after long storage periods. 1. Pour tablespoon of oil into spark plug hole. Crank engine a few times and try to start again. 2. Loose or broken spark plug. (Hissing noise will occur when trying to start.) 2. Tighten spark plug. If that does not work, replace spark plug. If problem persists, may have head gasket problem, see #3. 3. Loose cylinder head or damaged head gasket. (Hissing noise will occur when trying to start.) 3. Tighten head. If that does not remedy problem, replace head gasket. 4. Engine valves or tappets mis‑adjusted or stuck. 4. Have qualified technician adjust/ repair valves and tappets. Follow all safety precautions whenever diagnosing or servicing the generator or engine. Page 24 For technical questions, please call 1-888-866-5797. ITEM 61725 1. Check wire connections. 2. Incorrect spark plug gap or damaged spark plug. 2. Re-gap or replace spark plug. 3. Defective spark plug cap. 3. Replace spark plug cap. 4. Old or low quality gasoline. 4. Use only fresh 87+ octane stabilizer-treated unleaded gasoline. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 5. Incorrect compression. 5. Diagnose and repair compression. (Use Engine will not start: COMPRESSION RELATED section.) 1. Fuel tank empty or full of impure or low quality gasoline. 1. Fill fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 2. Low oil shutdown. 2. Fill engine oil to proper level. Check engine oil before EVERY use. 3. Defective fuel tank cap creating vacuum, preventing proper fuel flow. 3. Test/replace fuel tank cap. 4. Faulty magneto. 4. Have qualified technician service magneto. 5. Disconnected or improperly connected spark plug cap. 5. Secure spark plug cap. Engine stops when under heavy load 1. Dirty air filter 1. Clean element. 2. Engine running cold. 2. Allow engine to warm up prior to operating equipment. Engine knocks 1. Old or low quality gasoline. 1. Fill fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 2. Engine overloaded. 2. Do not exceed equipment’s load rating. 3. Incorrect spark timing, deposit buildup, worn engine, or other mechanical problems. 3. Have qualified technician diagnose and service engine. 1. Impure or low quality gasoline. 1. Fill fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.). 2. Engine too cold. 2. Use cold weather fuel and oil additives to prevent backfiring. 3. Intake valve stuck or overheated engine. 3. Have qualified technician diagnose and service engine. 4. Incorrect timing. 4. Check engine timing. Engine stops suddenly Engine backfires 1. Device not plugged in properly. Attached device doesn’t have power Attached device begins to operate abnormally 1. Turn off and unplug the device, then plug it back in again and turn on. 2. Circuit Breaker tripped. 2. Turn off and unplug device, reset Circuit Breaker, plug in device and turn on. 3. Product needs service. 3. Have product repaired. 1. Problem with device. 1. Immediately unplug device. Have device repaired by a qualified technician, or replace device. 2. Rated load capacity exceeded. 2. Lower the number of items plugged into the generator to stay within the rated capacity, or use a more powerful generator. Follow all safety precautions whenever diagnosing or servicing the generator or engine. ITEM 61725 Setup 1. Spark plug cap loose. Safety Probable Solutions Operation Engine misfires Possible Causes For technical questions, please call 1-888-866-5797. Page 25 Maintenance Problem Warranties Safety Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. Setup To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Emissions Control System Warranty Operation United States Emissions Control Defects Warranty Statement Harbor Freight Tools Emissions Control Defects Warranty Coverage The United States Environmental Protection Agency (herein EPA) and Harbor Freight Tools (herein HFT) are pleased to explain the emissions control system warranty on your 2014-2015 Small Off‑Road Engine (herein engine). Within the United States, new off‑road, spark-ignition engines certified for model year 2014-2015, must meet similar standards set forth by the EPA. HFT must warrant the emissions control system on your engine for the periods of time described below, provided there has been no abuse, neglect or improper maintenance of your engine. Engines are warranted for a period of two (2) years relative to emissions control parts defects, subject to the provisions set forth below. If any emissions related part on your engine is defective, the part will be repaired or replaced by HFT. Your emissions control system may include parts such as the carburetor or fuel-injection system, and the ignition system. Also included may be hoses, belts, connectors and other emissions‑related assemblies. Where a warrantable condition exists, HFT will repair your engine at no cost to you including diagnosis, parts and labor. Manufacturer’s Warranty Coverage Maintenance The 2014-2015 engines are warranted for two (2) years. If any emissions-related part on your engine is defective, the part will be repaired or replaced by HFT. Owner’s Warranty Responsibilities • As the engine owner, you are responsible for the performance of the required maintenance listed in your Owner’s Manual. HFT recommends that you retain all receipts covering maintenance on your engine, but HFT cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance. • As the engine owner, you should, however, be aware that HFT may deny you warranty coverage if your engine or a part has failed due to abuse, neglect, improper maintenance, or unapproved modifications. • You are responsible for shipping your engine to a HFT warranty station as soon as a problem exists. Contact the HFT Customer Service department at the number below to make shipping arrangements. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days. If you have any questions regarding your warranty rights and responsibilities, you should contact the Harbor Freight Tools Customer Service Department at 1-888-866-5797. Page 26 For technical questions, please call 1-888-866-5797. ITEM 61725 HFT warrants to a first retail purchaser and each subsequent purchaser that the engine is free from defects in materials and workmanship that cause the failure of warranted parts for a period of two (2) years after the date of delivery to the first retail purchaser. 2. No Charge Repair or Replacement Repair or replacement of any warranted part will be performed at no charge to the owner if the work is performed through a warranty station authorized by HFT. For emissions warranty service, contact the HFT Customer Service Department at 1-888-866-5797. Component parts which are not scheduled for replacement as required maintenance or are scheduled only for regular inspection to the effect of “repair or replace as necessary” are warranted for the warranty period. Any warranted part which is scheduled for replacement as required maintenance is warranted for the period of time up to the first scheduled replacement point for that part. Any replacement part, provided it is equivalent in durability and performance, may be used in performance of maintenance or repairs. The owner is responsible for commissioning a qualified technician/mechanic to perform all required maintenance, as outlined in the Inspection, Cleaning, and Maintenance section in this manual. 6. Warranted Parts 1) 3. Consequential Damages Coverage Coverage under this warranty shall also extend to the failure of any engine components caused by the failure of any warranted part while it is still covered under this warranty. 2) 4. Coverage Exclusions 3) 4) 5) Operation Warranty claims shall be filed in accordance with the provisions of the HFT warranty policy explained in the box at the top of the previous page. HFT shall not be liable for any loss of use of the engine, for any alternative usage, for any damage to goods, loss of time, or inconvenience. Warranty coverage shall also be excluded for any part which fails, malfunctions, or is damaged due to failure to follow the maintenance and operating instructions set forth in the Owner’s Manual including, but not limited to: a) Use of parts which are not authorized by HFT b) Improper installation, adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c) Failure to follow recommendations on fuel use contained in the Owner’s Manual d) Improper or inadequate maintenance of any warranted parts e) Repairs performed outside of the authorized warranty service dealers f) Alterations by changing, adding to or removing parts from the engine. Fuel Metering System i) Carburetor and its internal parts. ii) Fuel pump (if so equipped). iii) Cold start enrichment system. Air Induction System i) Intake pipe/manifold. ii) Air cleaner. Ignition System i) Spark plug. ii) Magneto ignition system. Catalyst System (if so equipped) i) Exhaust pipe stud. ii) Muffler. iii) Catalytic converter (if so equipped). Miscellaneous Items Used in Above Systems i) Vacuum, temperature and time sensitive valves and switches. ii) Hoses, belts, connectors, and assemblies. Safety 1. Length of Coverage 5. Service and Maintenance Setup Harbor Freight Tools Emissions Control Defects Warranty Provisions THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. Record Product’s Serial Number Here: Note: If product has no serial number, record month and year of purchase instead. ITEM 61725 Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. For technical questions, please call 1-888-866-5797. Page 27 Maintenance PLEASE READ THE FOLLOWING CAREFULLY Parts Lists and Diagrams Parts List Safety Part Setup Operation Maintenance 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Page 28 Description Cylinder Head Cover Bolt Cover, Cylinder Head Gasket, Cylinder Head Cover Plug, Spark Bolt, Cylinder Head Cylinder Head Right Cylinder Head Pin Gasket, Cylinder Head Cross-Band Veneer Stud Stud Cover, Cylinder Head Plug , Engine Oil Ring, Seal Crankcase Pin Washer, Flat Arm, Governor Seal, Oil Bolt, Drain Plug Washer, Flat Seal, Oil Strainer, Breath Groove Piece, Breath Gasket, Breath Groove Gasket, Breath Groove Plate, Breath Groove Cover Clamp Bolt Bolt Clamp Tube, Breather Gasket, Inlet Tube, Intake Nut Pump Asm, Gasoline Bolt Sleeve, Gasoline Pump Rubber Support, Gasoline Pump Strainer, Fuel Clamp Tube, Negative Pressure Tube, Negative Pressure Clamp Tube, Fuel Separator, Gas and Oil Tube, Fuel Mouth, Negative Pressure Sensor, Engine Oil Bolt Bolt Bolt Cover , Crankcase Pin Gasket, Crankcase Seal, Oil Tube, Suction Oil Washer Bolt Bolt Pin Pump Asm, Oil Cover, Oil Pump Spring, Pressure Relief Valve Ball, Steel Strainer, Oil Gear Asm, Governor Qty 2 1 2 2 8 1 1 4 4 2 4 4 1 1 1 1 2 3 1 1 2 2 1 1 1 1 1 1 1 2 2 2 1 2 1 4 1 3 2 1 1 6 1 1 2 1 1 1 1 1 2 7 2 1 2 1 1 1 1 2 2 2 1 1 1 1 1 1 Part 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 Description Oil Dipstick Gasket, Oil Pump Crankshaft Asm. Washer, Thrust Rod, Connecting Piston Pin, Piston Clip, Piston Pin Ring, The First Ring, The Second Ring Set, Oil Nut, Valve Lock Nut, Valve Adjusting Rocker, Valve Bolt, Valve Adjusting Lifter, Valve Tappet, Valve Seat, Valve Spring Check Ring Clamp, Valve Lock Spring, Valve Guide, Seal Retainer, Valve Spring Valve, Exhaust Valve, Intake Camshaft Asm. Washer, Camshaft Shield, Shroud Screw Nut Shroud Asm. Plate, Fan Shield Decorated Handle , Lock Shroud 2, Cylinder Body Diode Shroud, Cylinder Body Shield, Lower Bolt Sensor, Pressure Shield, Crankcase Side Bolt, Flange Shoulder Lug Bolt, Flange Shoulder Shield Shield Gasket, Oil Filter Cover Oil Filter Block Ring, Seal Tube, Oil Filter Installation Oil Filter Washer, Flat Adapter, Cooling Pipe Clamp Pipe, Cooling Pipe, Cooling Radiator Asm. Bolt Gasket Regulator, Voltage Clamp Gasket, Carburetor Gasket, Carburetor Insulator Joint, Intake Tube Bolt Bolt Washer Tube, Air Cleaner Connecting Bolt For technical questions, please call 1-888-866-5797. Qty 1 1 1 1 1 2 2 4 2 2 2 4 4 4 4 4 4 4 4 8 4 4 2 2 2 1 1 1 3 4 1 1 2 1 1 1 1 13 1 1 1 2 1 1 1 1 1 1 1 1 2 2 4 1 1 1 2 1 1 1 2 1 1 2 1 1 1 4 ITEM 61725 Parts List (continued) ITEM 61725 1 1 1 1 1 2 2 1 1 1 1 1 2 2 2 1 6 1 1 1 1 1 3 2 1 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 2 4 2 1 1 1 1 2 1 2 4 4 4 4 1 1 1 1 1 1 1 1 1 1 16 16 4 4 4 8 4 Part 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 Description Lifting Handle Screw Support, Engine Frame Shock Absorption Bolt Seat, Engine Frame Shock Absorption Bolt Regulator, Voltage Battery Bolt, Battery Nut Clamp, Battery Wire, Anode Wire, Cathode Clip Bolt Panel, Control Oil Temp Ind Protector, Overcurrent DC Cigarette Lighter Terminal, Grounding Socket, Power Supply Socket, Power Supply Socket, Power Supply Socket, Power Supply Harness, Control Panel Wiring Timer Key, Stop Engine Switch Switch Choke Zip Combination Protector, Overcurrent Protector, Overcurrent Breaker, Double-Pole Panel , Control Bolt Cover, Motor Front End Bracket, Motor Cover, Rear Motor Bolt, Stator Bolt, Rotor Washer, Flat Bolt Block, Terminal Brush , Carbon Band Nut Bolt Nut Washer, Flat Bolt Screw Motor Asm. Plate, Muffler Insulator Bolt Frame Cover Hinge Nut Guard Unit Protective Sleeve Bar, Handle Screw Cross Groove Pan Guard Unit 2 Bolt Thermal Baffle Tube, Handle Tube, Handle Seat, Handle Tube Connecting Bolt Nut Wheel, Front Nut Washer, Flat Shaft, Front Wheel For technical questions, please call 1-888-866-5797. Qty 1 1 2 8 2 2 1 1 2 2 1 1 1 2 2 1 1 1 1 1 1 1 1 2 1 1 1 1 1 3 2 1 1 6 1 1 1 4 1 1 8 1 1 4 4 4 2 4 2 1 1 1 4 2 8 1 1 1 2 2 8 1 1 2 2 6 6 2 4 2 2 Page 29 Safety Qty Setup Description Carburetor Asm. Clip, Governor Rod Line, Solenoid Valve AC Cleaner, Air Cover, Intake Tube Bolt Screw Collar Washer Tube, Fuel Coil, Ignition Coil, Ignition Bolt Stud Stud Coil , Charge Bolt Flywheel Asm. Washer Bolt, Flywheel Impeller Tray, Impeller Setting Bolt Pin Motor Asm,Starting Bolt Protector, Oil Bolt Control Asm, Throttle Bolt Spring, Governor Spring, Choke Return Spring, Governor Nut Bolt, Governor Support Support , Governor Rod, Governor Spring, Throttle Valve Returning Rod, Choke Clip, Choke Rod Bolt Nut Gasket, Exhaust Outlet Muffler Asm. Spark Collector Tank, Fuel Leveler Asm, Oil Screw, Cross Groove Pan Valve, One Way Tube, Fuel Sleeve, Fuel Tank Rubber Bush Washer, Flat Bolt Strainer, Fuel Chain Clip Cap Off The Chain Cover, Fuel Tank Cock Asm, Fuel Clamp Bellows Clamp Frame Asm, Engine Power Support Combination Bolt Nut Nut Washer, Flat Cushion, Engine Frame Bolt Bolt Operation 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 Maintenance Part Assembly Diagram 273 271 270 272 260 273 273 274 Safety 262 262 274 274 260 261 262 260 276 277 274 274 274 271 273 262 261 262 276 276 278 259 260 262 262 278 275 262 272 273 273 269 275 266 266 265 206 205 211 211 276 264 277 Setup 263 268 268 206 210 211 211 212 207 206 211 211 207 268 214 268 206 205 210 211 211 212 209 207 208 207 206 267 206 206 205 213 213 206 205 216 268 268 267 201 252 202 186 199 215 217 216 252 17 217 218 252 252 Operation 190 189 188 187 190 189 188 187 202 200 201 197 186 185 221 222 196 221 222 201 203 204 203 204 201 220 253 253 253 253 202 203 204 195 268 268 203 204 219 242 258 194 193 192 191 184 184 183 254 255 255 256 190 189 188 187 182 198 248 243 190 245 189 188 187 257 247 254 255 255 256 245 248 245 245 246 248 248 251 251 249 248250 248 248 Maintenance 244 248 251 251 ITEM 61725 For technical questions, please call 1-888-866-5797. Page 30 237237 235 234 239 240 52 54 224 225 223 230 229 227 Safety 237 236 231 52 57 228 226 241 241 56 55 55 241 241 241 241 62 62 63 70 64 60 69 59 58 61 60 68 61 178 178 77 78 79 177 178 178 73 181 123 121 106 108 104 106 106 106 102 177 107 106 76 74 179 Setup 238 231 52 52 53 65 76 75 109 110 124106 105 106 121 114 122 119 120 121 180 179 76 74 113 81 1 83 83 2 4 84 87 88 3 84 71 5 88 86 86 87 88 88 89 127 81 82 82 77 78 79 76 106 103 106 106 111 126 75 80 80 72 106 128 110 112 106 5 5 12 90 90 12 5 89 85 6 85 92 91 91 22 17 18 20 17 18 1918 21 147 49 8 8 85 12 95 93 12 8 9 85 14 15 5 13 3 5 9 10 8 9 80 81 10 82 83 1 11 7 5 9 35 36 42 36 38 42 39 38 33 89 32 90 91 4 5 11 11 11 80 81 82 93 30 37 38 163 162 162 161 157 155 156 160 41 36 36 34 2931 30 154 160 31 28 32 86 87 88 83 89 90 91 84 92 94 26 34 153 153 152 27 25 21 50 51 22 24 148 149 23 84 51 16 150 149 150 153 86 87 88 Operation 238 233 232 53 52 52 52 67 66 125 119 120 125 115 117 116 118 121 151 151 153 136 136 111 166 136 167 136 139 42 44 45 47 42 43 45 46 48 42 42 39 40 164 158 159 159 159 135 134 138 165 166 140a 140b 140c 140d 140e 140 142 141 145 140f 143 146 97 98 98 97 168 96 140g 175 171 176 173 172 129 130 129 131 133 132 132 143 142 144 137 128 169 170 174 99 98 97 98 100 101 101 Page 31 For technical questions, please call 1-888-866-5797. ITEM 61725 Maintenance Assembly Diagram (continued) 3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • 1-888-866-5797
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02 Instance ID : uuid:ad44dd43-a582-f540-b5ec-c928f5951f33 Original Document ID : adobe:docid:indd:a873f5cd-ca69-11df-874f-be20c629b62a Document ID : xmp.id:cf68b678-3635-43ea-b845-d6ab8e889a6b Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4d43e6ec-65f7-40cc-a35e-7f56c263dd79 Derived From Document ID : xmp.did:4d43e6ec-65f7-40cc-a35e-7f56c263dd79 Derived From Original Document ID: adobe:docid:indd:a873f5cd-ca69-11df-874f-be20c629b62a Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2015:01:28 10:52:44-08:00 Create Date : 2015:01:28 10:52:44-08:00 Modify Date : 2015:01:28 10:52:55-08:00 Metadata Date : 2015:01:28 10:52:55-08:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Export Script : Export pdf script v3.791 Format : application/pdf Rights : Copyright©2013 by Harbor Freight Tools®. All rights reserved. No portion of this document or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Web Statement : http://www.harborfreight.com Marked : True Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 32 Creator : Adobe InDesign CC 2014 (Macintosh)EXIF Metadata provided by EXIF.tools