Heiman Technology HS1CAZ Smart Carbon Monoxide Sensor User Manual

Shenzhen Heiman Technology Co.,Ltd. Smart Carbon Monoxide Sensor

User Manual

Download: Heiman Technology HS1CAZ Smart Carbon Monoxide Sensor User Manual
Mirror Download [FCC.gov]Heiman Technology HS1CAZ Smart Carbon Monoxide Sensor User Manual
Document ID3381800
Application ID05ZMaA/5XSujNoslAWflAA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize61.42kB (767786 bits)
Date Submitted2017-05-08 00:00:00
Date Available2017-05-08 00:00:00
Creation Date2016-09-13 02:01:17
Producing SoftwareCorel PDF Engine Version 14.0.0.653
Document Lastmod0000-00-00 00:00:00
Document Title智能一氧化碳报警器 HSICA-Z中性英文使用说明书.cdr
Document CreatorCorelDRAW
Document Author: USER

1.Working Voltage:DC3V(CR123A Lithium Battery)
Smart Carbon Monoxide Sensor
User Manual
2.Static Current:≤20uA
3.Alarm Current:≤60mA
7.Wireless Networking Distance:≥70m(open area)
8.Working Temperature:-10℃ ~ +50℃
9.Environment Humidity:≤ 95%RH
Networking Hole
LED Indicator
* Please read the user manual carefully before operation.
The guide picture is for reference only. please in kind prevail
Installation Step1
10.Dimension:60* 60*49.2mm
Installation Base
Sensor
boiler and places where sensor may false alarm.
Do not install in dirty, dusty or greasy places, oily,
dust or household chemicals may damage internal
sensor, and make sensor can not work normally.
4.Sensors can support wall mounted or placing on
the table, household and travel essential.
Bedroom
Livingroom
Bedroon
Aisle
Kitchen
Bedroom
Gagrage
Minimum recommended installation
Status
LED Indicator
Additional recommended installation
Status and battery replacement
Installation Step4
To increase safety factors in single-layer house,
suggest to install at least a sensor in each bedroom and
install a sensor at 6m from chimney and gas fixture.
To increase safety factors in multi-layer house, suggest
to install at least a sensor in each bedroom, install at
least one sensor in basement. Please install a sensor at
6m from chimney and gas fixture.
Basement
Installation Step3
Installation Step2
anywhere CO may leak, make sure each sleeping
area can hear sound alarm when choose
installation position.
2.Avoid suppressing or falling down sensors, keep
sensors away from humid, high voltage, strong
magnetic and children.
3 . Do not suggest install sensors in garage, kitchen,
Installation Drawing
6.Networking:Z-wave Ad-Hoc Networking
Tips
50ppm 60-90mins alarm
100ppm 10-40mins alarm
300ppm 3mins alarm
1 . Install the sensor in bedroom and living area or
Installation Instruction
4.Alarm Sound:85dB/1m
5.Alarm Sensitivity:30ppm 120mins alarm
Technical Data
Product Introduction
HS1CA-Z
This product is a smart carbon monoxide
sensor, adopts super low power consumption Zwave wireless networking technology, used for
detecting carbon monoxide. Sensor adopts high
performance electrochemical sensor, support
sound and flash alarm, It has high stability, super
low power consumption, little sensitivity drift and
many other features. Free installation design,
support instant bonding.
1, This product can not be used for detecting natural
gas(methane), propane, butane and other
combustible gas.
2, Clean once a month, users may use household
vacuum cleaner and soft brush when cleaning.
3, Do not use cleanser or solvent wipe sensors,
please avoid spraying air freshener, hair spray, oil
paint or other aerosol near sensors.
4, Effective working life span is 5 years, suggest
replace every 5 years no matter there is fault or
not. (Battery life span is 3 years).
5, Please be attention when alarm happens. Shut-off
valves immediately, opening the window, make
sure indoor airiness. Besides using sensors
c o r r e c t l y, u s e r s s h o u l d s t r e n g t h e n t h e
consciousness of fire protection.
Alarm
Test
Green-red-yellow-green LED flash alternatively once
4 beeps
Preheating
Green,red and yellow LED flash alternatively once
1 beep
Alarm
Red LED flash
4 beeps
Malfunction
Yellow LED flash twice every 10 seconds
2 beeps every 10 seconds
Low battery
Green LED flash every 53 seconds
1 beep every 53 seconds
Normal working
Red LED flash every 53 seconds
Expired sensor
Yellow LED flash twice
4 beeps every 10 seconds
Troubleshooting and test
Please take following advices for reference if sensors can not work normally:
1.Replace battery in time, if voltage too low and reach effective life span.
(Check table 1 for state reference)
2.Please clean sensor if the fault resulted from dust or oil stain ( Check table
1for state reference).
3.Make sure sensors screw into the base correctly.
Chart1
Anticlockwise rotating the bracket out from the installation
base, then remove the battery insulating strip to make
detector on power.
Click “Add Device” on the APP interface, and
enter the networking mode.
According to APP prompt, press the networking button 3 times in
1.5 seconds until green light flash, (the longest networking time
is 30 seconds) APP interface prompted, networking success.
Select device, click "delete" on APP,
then press the
networking button 3 times in 1.5 seconds until the green light
flashes slowly for 6 times, which indicates network is
disconnected successfully
C R 12
Screw the sensor into bracket, please remove the
double - sided adhesive membrane on the
installation base, and stick on the wall.
3A
Press test button on the product for 3 seconds, shows in above
picture, till alarm happens ( check table 1 for state reference).
Suggest test sensor at least once a week. Please pay attention once
*Please replace battery correctly, following the battery posi tive and
negative electrode.
10
alarm happens.
11
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved
by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Format                          : application/pdf
Creator                         : USER
Title                           : 智能一氧化碳报警器 HSICA-Z中性英文使用说明书.cdr
Creation Date--Text             : 
Mod Date--Text                  : 
Producer                        : Corel PDF Engine Version 14.0.0.653
Creator Tool                    : CorelDRAW
Modify Date                     : 2017:04:26 23:57:59+08:00
Metadata Date                   : 2017:04:26 23:57:59+08:00
Document ID                     : uuid:5128ce67-0ece-47b3-a39b-ac42a5528e58
Instance ID                     : uuid:313485a9-978d-4950-903b-9197988a7f9d
Page Count                      : 2
Create Date                     : D:20160913020117Z
Author                          : USER
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AK7XHS1CAZ

Navigation menu