Hewlett Packard Enterprise BJNGAFB0002 HP 425 Wireless 802.11n (AM) AP User Manual
Hewlett-Packard Company HP 425 Wireless 802.11n (AM) AP
Contents
- 1. user manual (statement) rev
- 2. user manual
user manual
Contents Preparing for installation ········································································································································································2 Safety recommendations ··········································································································································································2 Safety symbols·····················································································································································································2 General safety recommendations················································································································································2 Determining the installation position ··················································································································································2 Accessories provided with the AP ·························································································································································3 Installation preparation checklist ···························································································································································4 Installing the AP ·························································································································································································5 Mounting the AP on a table·····································································································································································5 Mounting the AP on a wall ·······································································································································································6 Mounting the AP to a T-rail ·····································································································································································9 Mounting the AP on a ceiling ·······························································································································································12 Connecting the power supply ·······························································································································································13 Connecting the AP to a local power supply ··························································································································13 Connecting the AP to a PoE power supply ····························································································································14 Connecting the AP to the network ······················································································································································14 Appendix A Chassis views and technical specifications ···········································································································16 Chassis views ································································································································································································16 Weights and dimensions ·······························································································································································17 Power consumption ········································································································································································17 Power specifications ··················································································································································································17 AC voltage range ··············································································································································································17 Power adapter specifications ······················································································································································17 Storage media and memory specifications ·····································································································································18 Appendix B LEDs ······················································································································································································19 Preparing for installation IMPORTANT: For regulatory identification purposes, the HP 425 is assigned a regulatory model number (RMN) BJNGA-FB0002. This regulatory number should not be confused with the marketing name HP 425, or product code JG653A, JG654A, JG655A, JG656A, JG687A, and JG688A. Safety recommendations WARNING! This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. Before installation and operation, read all of the safety instructions in Compliance and Safety Guide supplied with your AP. Safety symbols When reading this document, note the following symbols: WARNING means an alert that calls attention to important information that if not understood or followed can result in personal injury. CAUTION means an alert that calls attention to important information that if not understood or followed can result in data loss, data corruption, or damage to hardware or software. TIP means an alert that provides helpful information. General safety recommendations To avoid possible bodily injury or equipment damage, read the following safety recommendations before you install an HP 425. The recommendations do not cover every possible hazardous condition. Make sure the ground is dry and flat and anti-slip measures are in place. Keep the chassis clean and dust-free. Do not place the AP in a moist area and avoid liquid surrounding the AP. Keep the chassis and installation tools away from walkways. Determining the installation position 19 WARNING! Please carefully select the installation position and make sure the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty. Determine the installation position by observing the following principles: The product shall be installed at a location where the radiating antenna can be kept 40 cm (15.75 in) from nearby person in normal operation condition to meet regulatory RF exposure requirement. Leave as few obstacles (such as wall) as possible between APs and clients. Install APs away from electronic devices (such as microwave ovens) that might generate radio frequency (RF) noise. Install APs in a place where they will not hinder people's daily work and life. Do not install APs in a place where water seeping, water soaking, and condensing occur. Prevent water or moisture from entering the APs. Do not place the HP 425 on any metal surface. Place it on a place where there are no obstacles and good signal strength is available. Accessories provided with the AP WARNING! Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC/IC limit and is prohibited. Wall-mounting bracket T-rail holder First of 16 segment of MAC address EA=XXXXXXXXXXXX First of 16 segment of MAC address EA=XXXXXXXXXXXX First of 16 segment of MAC address EA=XXXXXXXXXXXX First of 16 segment of MAC address EA=XXXXXXXXXXXX MAC address label T-rail holder mounting screw Wall anchor kit Rubber feet 19 Hex-head bolt, washer, and nut Antennas, power adapter, and power cable are user-supplied. Installation preparation checklist Before you install an AP, verify the following items: Connect the power cord and connect the AP to the network. Examine the LED status to make sure the AP can operate correctly. For more information about AP LEDs, see "Appendix A Chassis views and technical specifications Chassis views The HP 425 provides the following external ports: Two 2.4 GHz antenna ports, two 5 GHz antenna ports A console port A 10/100/1000 Mbps copper Ethernet port A power supply port NOTE: The HP 425 also provides a reset button. Figure 1 HP 425 ports (1) 2.4G antenna port 2 (2) 2.4G antenna port 1 (3) 5G antenna port 1 (4) 5G antenna port 2 (5) Reset button (6) Console port 19 (7) 10/100/1000 Mbps copper Ethernet port (8) Local power port Table 1 HP 425 port description Port Standards and protocols Description 2.4G-1/2 IEEE802.11b IEEE802.11g IEEE802.11n The antenna ports are provided for 2.4 GHz single-RF antennas. 5G-1/2 IEEE802.11a IEEE802.11n The antenna ports are provided for 5 GHz single-RF antennas. 48V DC N/A The local power port is used for +48 VDC power supply to the device. ETHERNET IEEE802.3 IEEE802.3u IEEE802.3af 10/100/1000 Mbps copper Ethernet port .The Ethernet port can serve as an uplink interface to access the Internet or MAN, and as an 802.3af-compliant PoE port at the same time. Console port RS/EIA-232 The console port is used for configuration and management (for debugging when the AP operates as a fit AP). Weights and dimensions Item Description Height 51 mm (2.01 in) Width 188.6 mm (7.43 in) Depth 188.6 mm (7.43 in) Weight 640.5 g (22.59 oz) Power consumption Model Maximum power consumption HP 425 12.95 W Power specifications AC voltage range Table 2 AC voltage range Power supply mode Voltage range Frequency Single-phase three-wire (V) 100 V to 240 V 50 or 60 Hz 19 Power adapter specifications Item Description Input 100 VAC to 240 VAC Output +48V @ 0.63 A Storage media and memory specifications Item Description Nor Flash 4 MB Storage media Nand Flash 128 MB Memory DDR2 128 MB 19 Appendix B LEDs." Verify that cabling has been completed. The HP 425 supports 802.3af-compliant PoE. To achieve the best performance, HP recommends that you use GE connection to the power device. Record the MAC address and serial number of the AP (marked on the rear of the AP) for future use. If part of the power line is routed outdoors, use a power strip with lightning protection (user supplied) to connect the power cord of the AP to the power line. Installing the AP Figure 2 Installation flowchart Start Check before installation Ceiling mounting Determine the installation position T-rail mounting Attach the T-rail holder to the T-rail Attach the wallmounting bracket to the T-rail holder Mount the AP on a ceiling Mount the AP to a wall Mount the AP on a table Mount the wallmounting bracket to the ceiling Install the wallmounting bracket Install the AP Connect the power supply Connect the AP to the network End The HP 425 can only be used indoors. It has built-in antennas. When you install the AP, determine whether external antennas are needed. External antennas are not included with the AP and this document does not include external antenna installation procedures. Mounting the AP on a table 1. Attach the rubber feet supplied with the AP to the rear of the AP. Figure 3 Attaching the rubber feet 2. Place the AP on the table with the rubber feet facing down. 19 Figure 4 Mounting the AP on the table Mounting the AP on a wall IMPORTANT: Connect the AP to the network by using an Ethernet cable, and then install the AP to the wall-mounting bracket. To mount the AP on a wall, a wall-mounting bracket and wall anchor kit is required. Figure 5 Screw hole locations and sizes (in mm) 103.0 40.0 Ø 5.0 86.0 136.0 (1) Hook (2) Mounting hole (3) Clip (4) Mounting clip To mount the AP on a wall: 1. Use the wall-mounting bracket as a template to mark the locations of the mounting holes on the bracket. Drill three 5 mm (0.2 in) diameter holes on the marked mounting hole locations. 19 Figure 6 Drilling holes in the wall 40 mm 86 mm 2. Insert a wall anchor into each mounting hole, and tap the wall anchor with a rubber hammer until it is flush with the wall surface. Figure 7 Inserting a wall anchor 3. Align the holes in the wall-mounting bracket with the anchors and insert screws through the installation holes into the wall anchors. 4. Adjust the position of the wall-mounting bracket and tighten the screws. 19 Figure 8 Installing the wall-mounting bracket (1) Wall-mounting bracket (2) Hook (3) Clip (4) Screw 5. Connect the AP to the network by using an Ethernet cable. 6. Align the mounting keyhole on the rear of the AP over the hook on the wall-mounting bracket. See 錯誤! 找不到參照來源。. 7. Mount the AP on the hook on the wall-mounting bracket. See callout 1 in Figure 9. 8. Pull down the AP until it clicks into place. See callout 2 in Figure 9. 19 Figure 9 Mounting the AP to the wall mounting bracket Mounting the AP to a T-rail IMPORTANT: The width of the T-rail must be in the range of 16 mm to 28 mm (0.63 in to 1.10 in). 19 Figure 10 Screw hole locations and sizes (in mm) 103.0 40.0 Ø 5.0 86.0 136.0 (1) Hook (2) Mounting hole (3) Clip (4) Mounting clip Figure 11 T-rail holder (1) T-rail clip (2) M4 screw nut (3) Clip holder (4) T-rail holder (5) M3 screw nut (6) M4 × 5 screw (7) M3 × 8 screw (8) Mounting hook To mount the AP to a ceiling T-rail: 1. Loosen the two M3 × 8 screws on each clip holder. Do not remove the screws. 2. Adjust the T-rail clips to make the T-rail holder wider than the T-rail. See callout 1 in Figure 12. Then lock the T-rail with the T-rail holder according to the arrow indicated in callout 2 in Figure 12. 19 Figure 12 Attaching the T-rail holder to the T-rail 3. Tighten the four M3 × 8 screws on the two clip holders. 4. Verify that the T-rail holder is attached to the T-rail. 5. Hook the mounting clip (see callout 3 in Figure 13) of the wall-mounting bracket to the mounting hook (see callout 2 in Figure 13) of the T-rail holder. 6. Insert the two M4 × 5 screws (see callout 1 in Figure 13) through the two 5 mm (0.20 in) diameter holes on the wall-mounting bracket according to the dashed line shown in Figure 13 and attach the screws to the T-rail holder. 7. Verify that the wall-mounting bracket is attached to the T-rail. 8. Connect the AP to the network by using an Ethernet cable. 9. Install the AP to the wall-mounting bracket. For more information, see "Mounting the AP on a wall." Figure 13 Mounting the AP to the T-rail (1) M4 × 5 screw (2) Mounting hook (4) Hook 19 (3) Mounting clip Mounting the AP on a ceiling CAUTION: Verify that the AP is secured to the mounting bracket to avoid falloff. Do not use this method to mount the AP to a location made of low-intensity materials such as a plaster ceiling. If this installation method is required in such an environment, put a high-intensity plate beneath the ceiling to secure the installation. The ceiling tiles must be less than 18 mm (0.71 in) thick, and the ceiling can bear a weight of at least 5 kg (11.02 lb). The three bolt holes shown in Figure 14 are needed for mounting the AP on a ceiling. Figure 14 Bolt holes on the wall-mounting bracket (in mm) 40.0 Ø 5.0 86.0 (1) through (3) Bolt holes To install the AP on a ceiling: 1. Drill two 5.0 mm (0.20 in) diameter holes in the ceiling where you want to mount the AP. The distance between the two holes must be the same as the distance between the two bolt holes on the mounting bracket. 2. Insert the hex-head bolts into the bolt holes on the mounting bracket and the holes in the ceiling. From above the ceiling, fasten the hex nuts to the hex-head bolts to fix the mounting bracket to the ceiling. 3. Connect the AP to the network by using an Ethernet cable. 4. Install the AP to the wall-mounting bracket. For more information, see "Mounting the AP on a wall." 19 Figure 15 Installing the mounting bracket to a ceiling (1) Nut (2) Washer (3) Ceiling (4) Wall-mounting bracket (5) Hex-head bolt (6) Hook Connecting the power supply The HP 425 can be powered by using a local or PoE power supply. You can select either method as needed. Make sure the power supply for either method is well grounded before you power on the AP. Before connecting the local or PoE power supply, verify that the power supply is steady. You can use a local power source, uninterruptible power supply (UPS), or user-supplied power generator to supply power to the AP. After powering on the AP, examine the AP status LED. For more information about AP LEDs, see "Appendix A Chassis views and technical specifications Chassis views The HP 425 provides the following external ports: Two 2.4 GHz antenna ports, two 5 GHz antenna ports A console port A 10/100/1000 Mbps copper Ethernet port A power supply port NOTE: The HP 425 also provides a reset button. 19 Figure 16 HP 425 ports (1) 2.4G antenna port 2 (2) 2.4G antenna port 1 (3) 5G antenna port 1 (4) 5G antenna port 2 (5) Reset button (6) Console port (7) 10/100/1000 Mbps copper Ethernet port (8) Local power port Table 3 HP 425 port description Port Standards and protocols Description 2.4G-1/2 IEEE802.11b IEEE802.11g IEEE802.11n The antenna ports are provided for 2.4 GHz single-RF antennas. 5G-1/2 IEEE802.11a IEEE802.11n The antenna ports are provided for 5 GHz single-RF antennas. 48V DC N/A The local power port is used for +48 VDC power supply to the device. ETHERNET IEEE802.3 IEEE802.3u IEEE802.3af 10/100/1000 Mbps copper Ethernet port .The Ethernet port can serve as an uplink interface to access the Internet or MAN, and as an 802.3af-compliant PoE port at the same time. Console port RS/EIA-232 The console port is used for configuration and management (for debugging when the AP operates as a fit AP). Weights and dimensions 19 Item Description Height 51 mm (2.01 in) Width 188.6 mm (7.43 in) Depth 188.6 mm (7.43 in) Weight 640.5 g (22.59 oz) Power consumption Model Maximum power consumption HP 425 12.95 W Power specifications AC voltage range Table 4 AC voltage range Power supply mode Voltage range Frequency Single-phase three-wire (V) 100 V to 240 V 50 or 60 Hz Power adapter specifications Item Description Input 100 VAC to 240 VAC Output +48V @ 0.63 A Storage media and memory specifications Item Description Nor Flash 4 MB Storage media Nand Flash 128 MB Memory DDR2 128 MB 19 Appendix B LEDs." Connecting the AP to a local power supply The AP is not shipped with a power adapter or power cable. The HP 425 supports both listed AC and DC power adapters marked“LPS”or limited power source. You can connect the power port of the AP to the power source through a power adapter to supply power to the AP. Figure 17 Local power supply connection (1) Power port (2) Power adapter (3) Power source Connecting the AP to a PoE power supply CAUTION: Identify the marks for the network port and console port to avoid connection mistakes. When you apply 802.3af PoE power supply, connect one end of the network cable to the network port on the AP, and the other end to an Ethernet port on a PoE-capable device (for example, a PoE-capable Ethernet switch). If the uplink device of the AP is a PoE switch, use an Ethernet cable to directly connect the Ethernet port of the AP to the PoE device.(indoor used) 19 Figure 18 PoE connection (1) Ethernet port (2) Ethernet cable (3) PoE switch Connecting the AP to the network APs can access the Internet or metropolitan area network (MAN) through the Ethernet uplink interface. To implement Internet or MAN access, connect the Ethernet port of the AP to an Ethernet port of an Ethernet switch. When the AP operates as a fit AP, all of its settings are configured on the AC. You can use the display wlan ap all command to examine the AP status on the AC. When the AP status is R/M, the AP has been successfully connected to the AC.display wlan ap all Total Number of APs configured : 1 Total Number of configured APs connected : 1 Total Number of auto APs connected : 0 AP Profiles State : I = Idle, J = Join, JA = JoinAck, C = Config, R = Run, IL = ImageLoad KU = KeyUpdate, KC = KeyCfm -------------------------------------------------------------------------------AP Name State Model Serial-ID -------------------------------------------------------------------------------ap1 R/M 425-WW 219801A0FKC133000020 ------------------------------------------------------------------------------- 20 Appendix A Chassis views and technical specifications Chassis views The HP 425 provides the following external ports: Two 2.4 GHz antenna ports, two 5 GHz antenna ports A console port A 10/100/1000 Mbps copper Ethernet port A power supply port NOTE: The HP 425 also provides a reset button. Figure 19 HP 425 ports (1) 2.4G antenna port 2 (2) 2.4G antenna port 1 (3) 5G antenna port 1 (4) 5G antenna port 2 (5) Reset button (6) Console port (7) 10/100/1000 Mbps copper Ethernet port (8) Local power port Table 5 HP 425 port description Port Standards and protocols Description 21 Port Standards and protocols Description 2.4G-1/2 IEEE802.11b IEEE802.11g IEEE802.11n The antenna ports are provided for 2.4 GHz single-RF antennas. 5G-1/2 IEEE802.11a IEEE802.11n The antenna ports are provided for 5 GHz single-RF antennas. 48V DC N/A The local power port is used for +48 VDC power supply to the device. ETHERNET IEEE802.3 IEEE802.3u IEEE802.3af 10/100/1000 Mbps copper Ethernet port .The Ethernet port can serve as an uplink interface to access the Internet or MAN, and as an 802.3af-compliant PoE port at the same time. Console port RS/EIA-232 The console port is used for configuration and management (for debugging when the AP operates as a fit AP). Weights and dimensions Item Description Height 51 mm (2.01 in) Width 188.6 mm (7.43 in) Depth 188.6 mm (7.43 in) Weight 640.5 g (22.59 oz) Power consumption Model Maximum power consumption HP 425 12.95 W Power specifications AC voltage range Table 6 AC voltage range Power supply mode Voltage range Frequency Single-phase three-wire (V) 100 V to 240 V 50 or 60 Hz Power adapter specifications 22 Item Description Input 100 VAC to 240 VAC Output +48V @ 0.63 A Storage media and memory specifications Item Description Nor Flash 4 MB Storage media Nand Flash 128 MB Memory DDR2 128 MB 23 Appendix B LEDs Table 7 LED description Mark Color Status Description The AP is booting. NOTE: Flashing at 1 Hz Green When the AP operates as a fit AP, it is always in this state before it is registered to an AC. Breathing A client is connected to the 2.4G port. Flashing at 0.25 Hz The AP has been booted and has registered to the AC. It is in standby state (no client is connected to the AP). Flashing at 2 Hz The AP is updating its system software image. Breathing A client is connected to the 5G port. Steady on An initialization exception has occurred to the AP. Flashing at 1 Hz The AP cannot detect any radio interface. Flashing at 2 Hz An Ethernet port or radio interface is operating incorrectly. Breathing green and blue alternatively Clients are connected to both the 2.4G and 5G radio interfaces. Blue Red Alternating green and blue 24
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Annotate, Fill forms Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2013:06:13 18:32:56Z Creator Tool : Microsoft® Office Word 2007 Modify Date : 2013:06:13 19:28:33+08:00 Metadata Date : 2013:06:13 19:28:33+08:00 Format : application/pdf Creator : SaraWu Producer : Microsoft® Office Word 2007 Document ID : uuid:d099bf36-26e8-4174-9184-f4581a627129 Instance ID : uuid:2237a077-77c0-45b1-b4ae-024e1695931e Page Count : 24 Language : zh-TW Author : SaraWuEXIF Metadata provided by EXIF.tools