Honeywell Security Sensor CoE PP300850SE DUAL TEC Motion Sensor User Manual 800 13827 B DT8050A QIG 12 10 13
Honeywell Security Sensor CoE DUAL TEC Motion Sensor 800 13827 B DT8050A QIG 12 10 13
Contents
- 1. User Manual (1 of 2).PDF
- 2. User Manual (2 of 2).PDF
User Manual (1 of 2).PDF
DRAFT - QUICK INSTALL GUIDE - 12/10/13 DT8050A DT8050A DT8050A DT8050A DUAL TEC® Motion Sensor with Anti-Mask DUAL TEC® Motion Sensor with Anti-Mask DUAL TEC® Motion Sensor with Anti-Mask DUAL TEC® Motion Sensor with Anti-Mask Quick Installation Guide Quick Installation Guide (FR) Quick Installation Guide (SP) Quick Installation Guide (PG) 12” (30 cm) 6' 9" - 8' 9" (2.1 - 2.7 m) 7' 6" Optimal (2.3 m) Optimal Optimal Optimal * Keep Clear / Tenir à l'écart / Respetar obligatoriamente / Manter-se afastado #6 (3.5 mm) #6 x 1 1/4" (3.5 mm x 32 mm) B A Internal EOL Resistor DIP Switches Résistance interne EOL commutateur DIP Interruptores DIP internos EOL Resistor EOL interno Resistor DIP Switches Anti-mask Anti-masque Antienmascaramiento Anti-máscara DT8050A EOL KOhm ON ON 1 2 2.2 5.6 AM LED ON OFF MAX PULL TO DISABLE LOOK DOWN Enabled Activé Habilitado Habilitado ON EOL KOhm 1 2 2.2 5.6 MW SENSITIVITY W1 LOOK DOWN ON LED OFF *Disabled *Désactivé *Deshabilitado *Deshabilitado Microwave Range Adjustment Réglage de la portée Hyperfréquence Ajuste del rango de detección Microondas Ajuste de Alcance Microondas MAX MIN MW SENSITIVITY * Factory default / Réglage usine / Defecto de fábrica / Padrão de fábrica 5 24-20 AWG (0.2-0.52mm2) LED 0 VDC - Vsupply 1.8 mA max Trouble 30 mA 25 VDC Tamper 30 mA 25 VDC LED TBL TBL T Alarm 30 mA 25 VDC Power 18 mA 9 - 15 VDC NC V - V+ EOL 9 8 7 6 5 4 3 2 1 ON EOL KOhm 1 2 2.2 5.6 WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES / WIRING EXAMPLES FR) To connect all three outputs (sensor alarm, tamper and trouble/anti-mask) to one zone input: All alarm, tamper and trouble/anti-mask events are “alarms” when the system is armed or “fault” when disarmed. ES) To connect all three outputs (sensor alarm, tamper and trouble/anti-mask) to one zone input: All alarm, tamper and trouble/anti-mask events are “alarms” when the system is armed or “fault” when disarmed. PG) To connect all three outputs (sensor alarm, tamper and trouble/anti-mask) to one zone input: All alarm, tamper and trouble/anti-mask events are “alarms” when the system is armed or “fault” when disarmed. Control Panel Zone Zone COM Ground +12V T C NC V- V+ 9 8 7 6 5 4 3 2 1 LED TBL TBL T Sensor To connect all three outputs (sensor alarm, tamper and trouble/antimask) to one zone input: All alarm, tamper and trouble/anti-mask events are “alarms” when the system is armed or “fault” when disarmed. (On-Board, Internal EOLR) Anti-mask Enabled EOL ON ON EOL KOhm 1 2 2.2 5.6 Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. of the sensor clear. Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. of the sensor clear. Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. of the sensor clear. Note: A masking condition can occur when blocking or reflective material is placed in front of the sensor. of the sensor clear. To connect the sensor alarm output to one zone input and the tamper and trouble/anti-mask outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble/anti-mask are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble/anti-mask conditions. To connect the sensor alarm output to one zone input and the tamper and trouble/anti-mask outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble/anti-mask are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble/anti-mask conditions. To connect the sensor alarm output to one zone input and the tamper and trouble/anti-mask outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble/anti-mask are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble/anti-mask conditions. -2- Keep 12” (30cm) in front Keep 12” (30cm) in front Keep 12” (30cm) in front Control Panel Trouble Zone Zone Alarm COM Zone Ground +12V JUMPER V- V+ 9 8 7 6 5 4 3 2 1 LED TBL TBL T NC (On-Board, Internal EOLR) EOL ON Anti-mask Enabled W1 ON EOL KOhm 1 2 2.2 5.6 * Off-Board, External EOLR (Not supplied), best if installed inside the sensor housing. Cut Sensor To connect the sensor alarm output to one zone input and the tamper and trouble/anti-mask outputs to a second zone input: The alarm relay is wired to one zone; the tamper and trouble/anti-mask are wired to another zone; the control panel differentiates alarm conditions from tamper and trouble/anti-mask conditions. Keep 12” (30cm) in front Control Panel To connect the sensor alarm, tamper and trouble/anti-mask outputs to three separate zone inputs: The alarm, tamper and trouble/anti-mask are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble/anti-mask conditions. Trouble Zone Zone COM Tamper Zone Alarm Zone COM Zone Ground +12V V- V+ 9 8 7 6 5 4 3 2 1 LED TBL TBL T To connect the sensor alarm, tamper and trouble/anti-mask outputs to three separate zone inputs: The alarm, tamper and trouble/anti-mask are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble/anti-mask conditions. NC Sensor To connect the sensor alarm, tamper and trouble/anti-mask outputs to three separate zone inputs: The alarm, tamper and trouble/anti-mask are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble/anti-mask conditions. (On-Board, Internal EOLR) To connect the sensor alarm, tamper and trouble/anti-mask outputs to three separate zone inputs: The alarm, tamper and trouble/anti-mask are each wired to a separate zone; the control panel differentiates alarm, tamper and trouble/anti-mask conditions. Anti-mask Enabled EOL ON W1 ON Cut EOL KOhm 1 2 2.2 5.6 * Off-Board, External EOLR (Not supplied), best if installed inside the sensor housing. Walk Test Reset MAX 30 sec ON < 4 ft /1.2m MIN MW SENSITIVITY 4X (slowly) 10 45 AM LED 20 30 Top View Vue de dessus Vista Desde Arriba Vista Superior PLAN VIEW ALL ZONES Power Up Walk Test Normal Trouble AntiMask Red Slow Blink ON Alarm ON Alarm Fast Blink OFF Yellow OFF ON Microwave ON Microwave OFF Fast Blink Green OFF ON PIR ON PIR OFF OFF Side View Vue de coté Vista Lateral Vista Lateral 40’ 12 m 33’ 10 m 27’ 8m 20’ 6m 13’ 4m 7’ 2m 2.3m 1.85 0.5 7’ 13’ 20’ 27’ 33’ 40’ 46’ 53’ 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m A B Zones / Zones / Zonas / Zonas 7’ 2m 13’ 4m 20’ 6m 27’ 8m 33’ 10 m 40’ 12 m 0 LED 7’ 13’ 20’ 27’ 33’ 40’ 46’ 53’ 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m -3- Look-down / Basses / Vista Zona 0 / Vigilância inferior 12 Lower / Courtes / Cercana/ Mais baixas 10 Intermediate / Intermédiaires / Intermedia / Intermédias 36 Long / Longues / Largo Alcance / Longo alcance FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. APPROVAL/ LISTINGS: • • • • • FCC part 15, Class B verified IC ICES-003, Class B verified UL 639 ULC S306-03 SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. Product must be tested at least once each year. For appropriate wiring methods, refer to the National Electrical Code NFPA 70 and the Canadian Electrical Code (where applicable). Power must be provided by a power-limited UL603 Listed burglar alarm power supply with minimum 4 hours of standby power capability, or from a power-limited output of a UL Listed burglar alarm control unit with minimum 4 hours of standby power capability. For the latest documentation and online support information, please go to: Pour de l’assistance en ligne, visitez : Para recibir soporte en línea, visite: Para qualquer informação adicional, contacte: http://www.security.honeywell.com/hsc/resources/MyWebTech/ To protect the environment, a detailed installation guide is available on the Honeywell website – Please consider before printing the document! For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. Pour obtenir de l'information sur la garantie de ce produit, veuillez communiquer avec le représentant autorisé de Honeywell de votre région. Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto. Contacte o representante autorizado Honeywell local para obter informações relativas a garantia. 2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China. -4- 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security P/N 800-13827 12/13 Rev B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : E727032 Title : Microsoft Word - 800-13827-B_DT8050A-QIG_12-10-13 Create Date : 2013:12:10 05:54:16 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:12:20 10:50:13+08:00 Metadata Date : 2013:12:20 10:50:13+08:00 Producer : GPL Ghostscript 8.15 Document ID : uuid:e574d5df-6bb0-4376-97ae-9f528ac53e70 Instance ID : uuid:6203fcfd-85f6-46cd-ae83-b267b9b19626 Has XFA : No Page Count : 4 Author : E727032EXIF Metadata provided by EXIF.tools