Honeywell 202111TXR Switch User Manual EVORA Datasheet v2 0

INNCOM International Inc. Switch EVORA Datasheet v2 0

Manual.pdf

Download: Honeywell 202111TXR Switch User Manual EVORA Datasheet v2 0
Mirror Download [FCC.gov]Honeywell 202111TXR Switch User Manual EVORA Datasheet v2 0
Document ID1806077
Application IDrTChoVH/zbEuNvTo5moKlA==
Document DescriptionManual.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize68.12kB (851506 bits)
Date Submitted2012-10-02 00:00:00
Date Available2012-10-02 00:00:00
Creation Date2012-09-25 15:03:04
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2012-09-25 15:03:04
Document TitleMicrosoft Word - EVORA Datasheet v2.0.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: mahussain

Confidential
Copyright © 2012 INNCOM
EVORA Series Datasheet
Overview
The EVORA family of switches offers an elegantly designed, easy to use,
feature-rich user interface and control system providing a state-of-the-art
guestroom automation experience. EVORA allows guest control of multiple
lighting loads, temperature, drapes, and guest annunciation from multiple
switch locations in the guestroom. EVORA offers three different user interface
modules and multiple different Load Assemblies that include wired and
wireless communications, dimmers, and programmable controls designed to
operate within INNCOM’s Integrated Room Automation System (IRAS). The
EVORA system brings all guestroom control features into a sleekly designed
traditional keypad user interface.
Figure 1 EVORA Switch
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Up to 7 key configurations with up to 5 position key pad for programmable control of any IRAS feature
Nightlight configuration with 2 key positions
Doorbell configuration with 2 key positions
Optional multifunction key for up to 10 grouped features per device
Backlight illuminated keys and text
TRIAC dimmer
FET dimmer
Relay actuator
Master contactor application
12VDC power supply
Low-voltage adapter for load center applications
2.4Ghz 802.15.4 wireless RF network communications
S5bus wired network communications
Digital input for door switch contact / integration with the INNCOM energy management system (EMS)
Software programmable for any CBL feature
Application
EVORA was developed to extend INNCOM switch capabilities beyond those offered in the well-established SSeries (S217 and S5XX) product families and the innovative MODEVA series. The EVORA series uses a modular,
cross functional hardware platform that allows each of the three main products (multifunctional switch,
nightlight, and doorbell ) to share features in both hardware and software that were previously available only as
uniquely designed sub-assemblies in the legacy S-Series products.
EVORA has at its core the same Load Assembly (WBI) architecture used by INNCOM’s MODEVA line. The Load
Assembly is available in six configurations—500W relay, 500W TRIAC dimmer, 350W FET dimmer, 30A master
contactor, 200mA power supply, and a low-voltage adapter (LVA)—that provide the mechanical platform and load
bearing capability for the EVORA system. The EVORA series differs from MODEVA in several ways. It uses a
EVORA Datasheet
Page 2 of 10
standard dimension mounting bracket, for instance, allowing EVORAs to be ganged with other products (similar to
the S-Series). EVORA products come factory assembled.
Categories of Load Assembly Load Switching
•
TRIAC dimmer provides dimming control of resistive light loads such as incandescent, halogen, and
TRIAC dimmable LEDs. The TRIAC dimmer can dim 100–120VAC loads up to 500W.
•
FET dimmer dims capacitive loads such as dimmable fluorescent lamps and electronic ballasts. It can also
dim resistive loads such as incandescent, halogen, and dimmable LEDs. The FET dimmer is designed to
dim 100–120VAC up to 350W.
•
Relay power supply switches capacitive, inductive, resistive, and general purpose loads up to 500W.
•
Master contactor controls 30A relay at 120–240VAC.
•
200mA power supply used for applications where EVORA must be line powered but does not require
load dimming or switching.
•
Low-voltage adapter allows the EVORA products to run in a +12VDC powered device that does not
actuate a load. This is very similar to the legacy S5XX product.
Load Assembly Parallel Power Supplies
The WBI actuators operate in parallel to supply a higher load capacity on the +12VDC rail than that achievable by a
single actuator. The total output power of the actuators in parallel is based on the voltage specifications at maximum
load versus the output current at maximum load and nominal recovery time after a foldback condition occurs. This
design can aggregate up to 6 actuators into a system that permits up to a combined 990mA (~1A) +12VDC output.
See Class 2 Output table below.
Additional Load Assembly Technical Features
•
Air-gap relay required (for dimmers meeting UL 508). Where solid state dimmers are used, disengages
the load from the line power in the event that a failed actuator causes a short or a closed circuit (as with a
FET dimmer), a possible electric shock risk during routine maintenance or lamp replacement.
•
Additional overload detection circuit for FET dimmer that senses a catastrophic overload / short and
shuts down the dimmer to protect the solid state circuitry.
•
Dimming linearization curve may be set by application engineer to calibrate the duty cycle of a Pulse
Width Modulated signal driving the various lamp types that could be used.
•
Self contained actuator that can be used without the user interface. This is useful during installation (with
EVORA) and in repair to isolate symptoms related specifically to the actuator.
Load Assembly Installation
Locate the fuse panel and remove fuses or ensure the breaker is in the OFF position before installing the Load
Assembly.
1.
Pull the class-2 wires for Ground (Brown), +12VDC (Red) and S5bus (Orange) and digital inputs into the
wall box (See Wiring Diagrams). Make the connections using a dolphin DC-1000P Super B connector or
equivalent type connector to the S5bus or digital input harnesses and connect them to the appropriate
header on the Load Assembly.
2.
Prepare the line voltage wiring by stripping back the insulation 16mm (5/8th inch).
3.
Connect the Green (Earth) Cable attached to the Load Assembly Strap to Earth.
EVORA Datasheet
Page 3 of 10
4.
Wire the Load Assembly as described in the Wiring Diagrams. Depending on gang assembly using the
appropriate 10, 12, 14, 16, or 18 AWG wire nut.
5.
Push all wires back into the wall box and fasten the control to the wall box using the supplied mounting
screws. Be sure not to pinch or disconnect any of the wires.
6.
Ensure the intended load(s) are connected to the circuit.
7.
Replace the fuses in the fuse panel or move the breaker to ON before continuing.
Note: EVORA self test may require that an I/O map is configured. The following steps are general
guidance only. Installers should refer to the property-specific install and commissioning
documents for further guidance.
8.
Allow the EVORA switch to power up. To verify power, observe whether indicator light or backlight
illuminate or blink.
9.
Testing EVORA depends on the specific software configuration.
10. The EVORA User Interface will display start up behavior (refer to the property-specific installation and
commissioning guide(s) and then enter a self test mode for the first 20 seconds of operation.
Figure 2 Mounting Screw Holes
Figure 3 Decora Notch
EVORA Datasheet
Page 4 of 10
The EVORA and Load Assembly is supplied with two 1¼" 6/32 screws, two 3-pin S5bus harnesses and a two-pin
pig-tail harness for the digital input.
Wiring Diagrams
Figure 4 EVORA WBI Single Wiring
Figure 5 EVORA WBI Double Wiring
EVORA Datasheet
Page 5 of 10
Figure 6 EVORA WBI Triple Wiring
In double and triple configurations, refer to the wiring diagram for S5bus and digital input connections. Daisy
chaining is required only if all EVORA units need to be on the same S5bus or a parallel power design is needed
for higher load capacity (See Class 2 Output table below).
Master Contactor
Use for master contactor applications up to 30A. This assembly requires an external +12VDC source.
Figure 7 EVORA WBI Master Contactor Wiring
EVORA Datasheet
Page 6 of 10
WBI Power Supply
Use for applications where EVORA must be line powered but does not require load dimming or switching.
200mA DC output.
Figure 8 EVORA WBI Power Supply Wiring
Low Voltage Adapter
The EVORA can be equipped with the Low Voltage Adapter (LVA). This allows the EVORA to act as a remote,
+12VDC powered device only.
Figure 9 EVORA WBI Low Voltage Adapter Wiring
EVORA Datasheet
Page 7 of 10
Technical Specifications
User Interface
Maximum # of inputs
Alternate User Interface
Communications
Input Power
Audio
Micro controller
Dimensions
Tactile input
1-7 tactile keys
Keypad—traditional mechanical switches
Wired S5bus
2.4Ghz RF
12VDC, up to 250mA*
8 ohm, 0.5W speaker for door bell chime
16Mhz, 32-bit ARM based MCU
1 3/4” W x 1 3/4” D x4” H (including brackets)
45 mm W x 45 mm D x 100 mm H (including brackets)
FCC ID: GTC202111TXR
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
—
—
—
—
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate this equipment.
IC: 1609A-201217TXR
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
EVORA Datasheet
Page 8 of 10
Load Specifications
Single Gang Installation
The following table provides the load ratings at absolute maximum based on the load type in a single gang wall box.
Actuator
Ratings
Voltage
SMPS
Relay Actuator
TRIAC Dimmer
MOSFET Dimmer
Master Contactor
Frequency
Power / Amperes
120-240Vac
50/60Hz
200mA
120-240 Vac
120-240 Vac
120-240 Vac
120-240 Vac
120 Vac
120 Vac
120 Vac
120 Vac
120 Vac
120 Vac
120 Vac
120 Vac
120 Vac
120-240 Vac
120-240 Vac
120-240 Vac
120-240 Vac
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
4.1 A
4.1 A
500 W
250 VA
1/10 HP
2.9 A
500 W
250 VA
1/10 HP
2.9 A
2.9 A
350 W
250 VA
7200VA
960W
800VA
30A
Load Type
+12VDC Output
Only
Resistive
General Purpose
Tungsten / ELV
Electric Ballast
Motor
Resistive
Tungsten / ELV
Electronic Ballast
Motor
Resistive
General Purpose
Tungsten / ELV
Electronic Ballast
General Purpose
Tungsten / ELV
Electronic Ballast
Resistive
Class-2 Output
The Load Assembly has been designed to provide +12VDC power to devices connected to the S5bus. The Load
Assemblies can operate in parallel to supply a higher total load capacity than that achievable by a single Load
Assembly. However, the total output is derated as per the table below for accommodating the stability of the
power supply circuitry. The total available output power must be shared with the EVORA User Interface. Refer to
the following table for Class-2 Output ratings.
Number of Load
Assemblies
Nominal Voltage
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
Voltage at Maximum
Load
+11.0VDC
+11.0VDC
+11.1VDC
+11.1VDC
+11.2VDC
+11.2VDC
Output Rating
200mA
375mA
550mA
660mA
880mA
990mA
EVORA Datasheet
Page 9 of 10
Operating Conditions
Table Header
Table Header
Storage
Operating
68-176 degrees F; 20–80 degrees C, non-condensing
50-122 degrees F; 10–50 degrees C, non-condensing
Ordering Information
The highly configurable EVORA product line features many options for function (programmable control, doorbell,
nightlight), appearance, user interface, and Load Assembly. The Ordering Guide below is for the EVORA final
assembly. For detailed ordering information for all EVORA components, see the EVORA Ordering Guide.
Final Assembly
OPN
Description
Multifunction/Doorbell
Nightlight
201-217
201-564
Power Supply
OPN
Description
500W TRIAC Dimmer
350W FET Dimmer
500W Relay Actuator
30A Master Contactor
200mA Power Supply
Low Voltage Adapter
Part Number
T5
F3
R5
3M
PS
LVA
Part Number
03-7051
03-7052
03-7050
03-0310
03-7053
03-7073
EVORA Datasheet
Page 10 of 10
Logic
OPN
Description
1–5 button logic board w/radio
2 button nightlight logic board w/
radio
2 button logic board w/radio
MB
NL
202-111
202-113
DB
202-114
Button
OPN
Description
1, 2, 3, 3b, 4, 4b, 5 button (Nightlight
and Doorbell are 2 button only)
Part Number
Housing Color
OPN
Description
White
Black
Light Almond
Eagle Almond
Part Number
Part Number
WH
BK
LA
EA
Document Revision History
Revision
0.1
0.2
0.3
1.0
1.01
2.0
Date Issued
10-Mar-2012
15-Mar-2012
22-Mar-2012
23-Mar-2012
29-Jun-2012
07-Sep-2012
Reason
First draft
Incorporated R&D review comments
Updated drawings and Load Assembly text
Incorporated Marketing comments and released
Incorporate new load assemblies, order guide, IC statement
Incorporate FCC statement changes and republish

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 10
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2012:09:25 15:03:04
Modify Date                     : 2012:09:25 15:03:04
Title                           : Microsoft Word - EVORA Datasheet v2.0.doc
Creator                         : PScript5.dll Version 5.2.2
Author                          : mahussain
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GTC202111TXR

Navigation menu