Honeywell 50025034 50025034 User Manual B
Honeywell International Inc. 50025034 B
Contents
User Manual B
OneWireless XYR 6000 Pressure Transmitter User's Manual 34-XY-25-15 Revision 3 6/24/08 Notices and Trademarks Copyright 2008 by Honeywell International Inc. Revision 3 June 24, 2008 While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers. In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice. Honeywell, PlantScape, Experion PKS, and TotalPlant are registered trademarks of Honeywell International Inc. Other brand or product names are trademarks of their respective owners. Honeywell International Process Solutions 2500 West Union Hills Phoenix, AZ 85027 1-800 343-0228 ii OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 About This Document This document describes preparation, operation and maintenance of the XYR 6000 Wireless Pressure Transmitters. Mounting, installation and wiring are covered in other documents. Honeywell does not recommend using devices for critical control where there is a single point of failure or where single points of failure result in unsafe conditions. OneWireless is targeted at open loop control, supervisory control, and controls that do not have environmental or safety consequences. As with any process control solution, the end-user must weigh the risks and benefits to determine if the products used are the right match for the application based on security, safety, and performance. Additionally, it is up to the end-user to ensure that the control strategy sheds to a safe operating condition if any crucial segment of the control solution fails. Revision Information Document Name Document ID Revision Number Publication Date XYR 6000 Pressure Transmitter User's Manual 34-XY-25-15 6/7/07 8/7/07 6/24/08 References The following list identifies all documents that may be sources of reference for material discussed in this publication. Document Title XYR 6000 Transmitters Quick Start Guide Getting Started with Honeywell OneWireless Solutions OneWireless Wireless Builder User’s Guide OneWireless Builder Parameter Reference Support and contact info United States and Canada Contact: Honeywell Solution Support Center Phone: 1-800 822-7673. In Arizona: 602- 313-5558 Calls are answered by dispatcher between 6:00 am and 4:00 pm Mountain Standard Time. Emergency calls outside normal working hours are received by an answering service and returned within one hour. Facsimile: (602) 313-3293 Mail: Honeywell TAC, MS P13 2500 West Union Hills Drive Phoenix, AZ, 85027 Revision 4 6/8/08 OneWireless XYR 6000 Pressure Transmitter User's Manual iii Europe Contact: Phone: Facsimile: Mail: Honeywell TAC-EMEA +32-2-728-2732 +32-2-728-2696 TAC-BE02 Hermes Plaza Hermeslaan, 1H B-1831 Diegem, Belgium Contact: Phone: Honeywell Global TAC – Pacific 1300-300-4822 (toll free within Australia) +61-8-9362-9559 (outside Australia) +61-8-9362-9564 Honeywell Limited Australia 5 Kitchener Way Burswood 6100, Western Australia GTAC@honeywell.com Pacific Facsimile: Mail: Email: India Contact: Phone: Facsimile: Mail: Email: Honeywell Global TAC – India +91-20- 6603-9400 +91-20- 6603-9800 Honeywell Automation India Ltd. 56 and 57, Hadapsar Industrial Estate Hadapsar, Pune –411 013, India Global-TAC-India@honeywell.com Korea Contact: Phone: Facsimile: Mail: Email: Honeywell Global TAC – Korea +82-2-799-6317 +82-11-9227-6324 +82-2-792-9015 Honeywell Co., Ltd 17F, Kikje Center B/D, 191, Hangangro-2Ga Yongsan-gu, Seoul, 140-702, Korea Global-TAC-Korea@honeywell.com People’s Republic of China Contact: Honeywell Global TAC – China Phone: +86- 21-5257-4568 Mail: Honeywell (China) Co., Ltd 33/F, Tower A, City Center, 100 Zunyi Rd. Shanghai 200051, People’s Republic of China Email: Global-TAC-China@honeywell.com iv OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 Singapore Contact: Phone: Facsimile: Mail: Email: Honeywell Global TAC – South East Asia +65-6580-3500 +65-6580-3501 +65-6445-3033 Honeywell Private Limited Honeywell Building 17, Changi Business Park Central 1 Singapore 486073 GTAC-SEA@honeywell.com Taiwan Contact: Phone: Facsimile: Mail: Email: Honeywell Global TAC – Taiwan +886- 7- 536-2567 +886-7-536-2039 Honeywell Taiwan Ltd. 17F-1, No. 260, Jhongshan 2nd Road. Cianjhen District Kaohsiung, Taiwan, ROC Global-TAC-Taiwan@honeywell.com Japan Contact: Phone: Facsimile: Mail: Email: Honeywell Global TAC – Japan +81-3-6730-7160 +81-3-6730-7228 Honeywell Japan Inc. New Pier Takeshiba, South Tower Building, 20th Floor, 1-16-1 Kaigan, Minato-ku, Tokyo 105-0022, Japan Global-TAC-JapanJA25@honeywell.com World Wide Web Honeywell Solution Support Online: http://www.honeywell.com/ps Elsewhere Call your nearest Honeywell office. Training Classes Honeywell Automation College: http://www.automationcollege.com Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual Symbol Definitions The following table lists those symbols used in this document to denote certain conditions. Symbol Definition ATTENTION: Identifies information that requires special consideration. TIP: Identifies advice or hints for the user, often in terms of performing a task. CAUTION Indicates a situation which, if not avoided, may result in equipment or work (data) on the system being damaged or lost, or may result in the inability to properly operate the process. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION symbol on the equipment refers the user to the product manual for additional information. The symbol appears next to required information in the manual. WARNING: Indicates a potentially hazardous situation, which, if not avoided, could result in serious injury or death. WARNING symbol on the equipment refers the user to the product manual for additional information. The symbol appears next to required information in the manual. WARNING, Risk of electrical shock: Potential shock hazard where HAZARDOUS LIVE voltages greater than 30 Vrms, 42.4 Vpeak, or 60 VDC may be accessible. ESD HAZARD: Danger of an electro-static discharge to which equipment may be sensitive. Observe precautions for handling electrostatic sensitive devices. Protective Earth (PE) terminal: Provided for connection of the protective earth (green or green/yellow) supply system conductor. Functional earth terminal: Used for non-safety purposes such as noise immunity improvement. NOTE: This connection shall be bonded to Protective Earth at the source of supply in accordance with national local electrical code requirements. Earth Ground: Functional earth connection. NOTE: This connection shall be bonded to Protective Earth at the source of supply in accordance with national and local electrical code requirements. Chassis Ground: Identifies a connection to the chassis or frame of the equipment shall be bonded to Protective Earth at the source of supply in accordance with national and local electrical code requirements. continued vi OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 Symbol Description ® The Factory Mutual Approval mark means the equipment has been rigorously tested and certified to be reliable. The Canadian Standards mark means the equipment has been tested and meets applicable standards for safety and/or performance. The Ex mark means the equipment complies with the requirements of the European standards that are harmonised with the 94/9/EC Directive (ATEX Directive, named after the French "ATmosphere EXplosible"). For radio equipment used in the European Union in accordance with the R&TTE Directive the CE Mark and the notified body (NB) identification number is used when the NB is involved in the conformity assessment procedure. The alert sign must be used when a restriction on use (output power limit by a country at certain frequencies) applies to the equipment and must follow the CE marking. The C-Tick mark is a certification trade mark registered to ACMA (Australian Communications and Media Authority) in Australia under the Trade Marks Act 1995 and to RSM in New Zealand under section 47 of the NZ Trade Marks Act. The mark is only to be used in accordance with conditions laid down by ACMA and RSM. This mark is equal to the CE Mark used in the European Union. N314 directly under the logo is Honeywell’s unique supplier identification number. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual vii Contents 1. INTRODUCTION .................................................................................................... 1 1.1 Purpose ..........................................................................................................................................1 1.2 Scope..............................................................................................................................................1 1.3 OneWireless network overview ...................................................................................................1 1.4 About the transmitter....................................................................................................................1 2. SPECIFICATIONS ................................................................................................. 3 2.1 European Union Usage.................................................................................................................3 2.2 Certifications and approvals........................................................................................................4 Transmitter .............................................................................................................................................................4 Authentication Device.............................................................................................................................................5 3. PREPARATION ................................................................................................... 11 3.1 Installation ...................................................................................................................................11 3.2 Configuration...............................................................................................................................11 3.3 Connecting to network ...............................................................................................................11 3.4 Calibrating the transmitter .........................................................................................................11 Overview ..............................................................................................................................................................11 Calibrate zero .......................................................................................................................................................11 4. FUNCTION BLOCKS........................................................................................... 13 4.1 Introduction .................................................................................................................................13 4.2 Block description ........................................................................................................................13 Block types ...........................................................................................................................................................13 Block diagram.......................................................................................................................................................13 4.3 5. Parameter details ........................................................................................................................14 OPERATION ........................................................................................................ 15 5.1 Overview ......................................................................................................................................15 Display modes ......................................................................................................................................................15 Authentication Device...........................................................................................................................................15 5.2 Transmitter connection status...................................................................................................16 5.3 Transmitter PV display ...............................................................................................................17 5.4 Transmitter quick view of parameters ......................................................................................21 5.5 Transmitter menu ........................................................................................................................22 Menu tree .............................................................................................................................................................22 Revision 4 6/8/08 OneWireless XYR 6000 Pressure Transmitter User's Manual ix Contents 5.6 Authentication device menus ....................................................................................................23 Overview .............................................................................................................................................................. 23 Main menu ........................................................................................................................................................... 23 Security and Node Deployment ........................................................................................................................... 24 Device Local Configuration .................................................................................................................................. 26 Read Node Information ........................................................................................................................................ 27 Advanced Options................................................................................................................................................ 29 6. MAINTENANCE/REPAIR .................................................................................... 30 6.1 Introduction .................................................................................................................................30 6.2 Preventive maintenance .............................................................................................................30 6.3 Inspecting and cleaning barrier diaphragms ...........................................................................30 Tools required ...................................................................................................................................................... 30 Procedure ............................................................................................................................................................ 31 Torque ratings ...................................................................................................................................................... 32 6.4 Replacing sensor module ..........................................................................................................33 Tools required ...................................................................................................................................................... 33 Procedure ............................................................................................................................................................ 33 6.5 Replacing batteries .....................................................................................................................35 When to replace................................................................................................................................................... 35 Tools required ...................................................................................................................................................... 35 Procedure ............................................................................................................................................................ 35 6.6 Replacing antenna ......................................................................................................................37 Tools required ...................................................................................................................................................... 37 Procedure ............................................................................................................................................................ 37 6.7 Parts .............................................................................................................................................39 Transmitter body .................................................................................................................................................. 39 Meter body ........................................................................................................................................................... 41 6.8 Dimension drawings ...................................................................................................................46 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 Contents Tables Tables Table 1 Calibrate zero .................................................................................................................................12 Table 2 Transmitter connection status ........................................................................................................16 Table 3 PV engineering units ......................................................................................................................17 Table 4 PV status ........................................................................................................................................18 Table 5 Device status ..................................................................................................................................18 Table 6 Menu tree........................................................................................................................................22 Table 7 Buttons for Device Local Configuration ..........................................................................................26 Table 8 Advanced Options ..........................................................................................................................29 Table 9 Inspecting and Cleaning Barrier Diaphragms.................................................................................31 Table 10 Process Head Bolt Torque Ratings ..............................................................................................32 Table 11 Sensor module replacement.........................................................................................................33 Table 12 Battery replacement procedure ....................................................................................................35 Table 13 Antenna replacement procedure ..................................................................................................38 Table 14 Parts (see Figure 12, Figure 13)..................................................................................................42 Table 15 Parts (see Figure 14)....................................................................................................................45 Table 16 Drawing numbers for DP models STDW924, STDW930, STDW974 ..........................................46 Table 17 Drawing numbers for DHGP models STGW944, STGW974 .......................................................46 Table 18 Drawing numbers for GP/AP models STGW94L, STGW97L, STGW98L, STAW94L .................46 Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual xi Contents Figures Figures Figure 1 XYR 6000 Functional Diagram .......................................................................................................2 Figure 2 Block Diagram ...............................................................................................................................13 Figure 3 Main menu.....................................................................................................................................23 Figure 4 Security and Node Deployment.....................................................................................................24 Figure 5 Device Local Configuration screen................................................................................................26 Figure 6 Read Node Information .................................................................................................................27 Figure 7 Advanced Options .........................................................................................................................29 Figure 8 Assembly of DP Transmitter Process Heads ................................................................................32 Figure 9 Sensor module removal and replacement ....................................................................................34 Figure 10 Battery replacement ....................................................................................................................36 Figure 11 Antenna replacement ..................................................................................................................39 Figure 12 STDW924, STDW930, STDW974..............................................................................................41 Figure 13 STGW944, STGW974 .................................................................................................................41 Figure 14 STGW94L, STGW97L, STGW987L, STAW94L .........................................................................45 xii OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 1. Introduction 1.1. Purpose 1. Introduction 1.1 Purpose This manual describes the Honeywell OneWireless XYR 6000 Pressure Transmitter function, operation and maintenance. 1.2 Scope The manual includes: 1.3 • Details of topics that relate uniquely to the Honeywell XYR 6000 Pressure Transmitter, • This manual does not cover installation, mounting, or wiring. See XYR 6000 Transmitter Quick Start Guide (document 34-XY-25-21). OneWireless network overview OneWireless is an all digital, serial, two-way communication mesh network that interconnects industrial field sensors to a central system. OneWireless has defined standards to which field devices and operator stations communicate with one another. The communications protocol is built as an "open system" to allow all field devices and equipment that are built to OneWireless standard to be integrated into a system, regardless of the device manufacturer. This interoperability of devices using OneWireless technology is to become an industry standard for automation systems. 1.4 About the transmitter The XYR 6000 Pressure Transmitter is furnished with OneWireless interface to operate in a compatible distributed OneWireless system. The transmitter will interoperate with any OneWireless-registered device. The transmitter includes OneWireless electronics for operating in a 2.4GHz network. It features function block architecture. The XYR 6000 Pressure Transmitter comes in a variety of models for measurement applications involving one of these basic types of pressure: • Differential pressure, • Gauge pressure, • Absolute pressure. The transmitter measures the process pressure and transmits the measured value as a digital output signal in user-configured engineering units. Its major components are an electronics housing and a meter body as shown in Figure 1 (a typical differential pressure model transmitter). The XYR 6000 transmits its output in a digital OneWireless protocol format for direct digital communications with systems. The Process Variable (PV) is available for monitoring and alarm purposes. Available PV update rates: 1, 5, 10, 30 seconds and are set on Wireless Builder. Slower update rates extend battery life. The meter body temperature is also available as a secondary variable for monitoring. Figure 1 shows a block diagram of the XYR 6000 Pressure transmitter’s operating functions. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 1. Introduction 1.4. About the transmitter Configuration Data Factory Characterization Data Measurement Board DP or AP Sensor EEPROM Pressure Input SP Sensor Multiplexer A/D EEPROM Microprocessor Microprocessor EEPROM Temp Sensor Radio Board Antenna Battery Meter Body Electronics Housing Configuration Data Figure 1 XYR 6000 Functional Diagram OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 2. Specifications 2.1. European Union Usage 2. Specifications 2.1 European Union Usage This product may be used in any of the following European Union nations. ISO 3166 ISO 3166 Country Country 2 letter code 2 letter code Austria AT Latvia LV Belgium BE Liechtenstein LI Bulgaria BG Lithuania LT Cyprus CY Malta MT Czech Republic CZ Netherlands NL Denmark DK Norway NO Estonia EE Poland PL Finland FI Portugal PT France FR Romania RO Germany DE Slovakia SK Greece GR Slovenia SI Hungary HU Spain ES Iceland IS Sweden SE Ireland IE Switzerland CH Italy IT United Kingdom BG Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 2. Specifications 2.2. Certifications and approvals 2.2 Certifications and approvals Transmitter Refer to product lable for applicable ratings. Approval / Item Ratings / Description CSAcus Intrinsically Safe CL I, Div 1, Groups A, B, C, & D; CL II, Div 1, Groups E, F & G; CL III, T4 CL I, Zone 0: Ex ia IIC, T4; CL I, Zone 0: AEx ia IIC, T4 CSAcus Explosionproof CL I, Div 1, Groups A, B, C, & D; CL II, Div 1, Groups E, F & G; CL III, T4 CL I, Zone 1: Ex d IIC, T4; CL I, Zone 1: AEx d IIC, T4 CSAcus Nonincendive CL I, Div 2, Groups A, B, C & D; CL II, Div 2, Groups F & G; CL III, Div 2, T4 CL I, Zone 2: Ex nA IIC, T4; CL I, Zone 2: AEx nA IIC, T4 FM Approvals CL I, Div 1, Groups A, B, C, & D; CL II, Div 1, Groups E, F & G; CL III, T4 Intrinsically Safe CL I, Zone 0: AEx ia IIC, T4 FM Approvals CL I, Div 1, Groups A, B, C, & D; CL II, Div 1, Groups E, F & G; CL III, T4 Explosionproof CL I, Zone 1: AEx d IIC, T4 FM Approvals CL I, Div 2, Groups A, B, C & D; CL II, Div 2, Groups F & G; CL III, Div 2, T4 Nonincendive CL I, Zone 2: AEx nA IIC, T4 HON – ATEX , Ex nA IIC, T4; Ta = 85°C, Zone 2 Non-Sparking Process Connections in Division 2 / Zone 2 Division 2 / Zone 2 apparatus may only be connected to processes classified as non-hazardous or Division 2 / Zone 2. Connection to hazardous (flammable or ignition capable) Division 1 / Zone 0, or 1 process is not permitted. Enclosure Type Type 4X, IP 66/67 CRN Canadian Registration Number Class II and III installations and for Type 4X/IP66 applications require that all cable and unused entires be sealed with an NRTL listed cable gland or seal fitting. Cable glands and seal fittings are not supplied by Honeywell. For detailed transmitter specifications see the following Specification and Model Selection Guides. • XYR 6000 Wireless Transmitter Differential Pressure (document 34-XY-03-22) • XYR 6000 Wireless Transmitter Absolute Pressure (document 34-XY-03-23) • XYR 6000 Wireless Transmitter Gauge Pressure (document 34-XY-03-24) OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 2. Specifications 2.3. Agency compliance information 2.3 Agency compliance information This section contains the Federal Communications Commission (FCC), Industry Canada (IC) and Radio Frequency compliance statements for the OneWireless Multinode device. ATTENTION XYR6000 units must be professionally installed in accordance with the requirements specified in the OneWireless XYR6000 Agency Compliance Professional Installation Guide. FCC compliance statements • This device complies with Part 15 of FCC Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. • Intentional or unintentional changes or modifications must not be made to the Multinode unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty. IC compliance statements • To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropic radiated power (EIRP) is not more than that permitted for successful communication. • Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. • This Class A digital apparatus complies with Canadian ICES-003. • French: Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Radio Frequency (RF) statement To comply with FCC’s and Industry Canada’s RF exposure requirements, the following antenna installation and device operating configurations must be satisfied. • Remote Point-to-Multi-Point antenna(s) for this unit must be fixed and mounted on outdoor permanent structures with a separation distance between the antenna(s) of greater than 20cm and a separation distance of at least 20cm from all persons. • Remote Fixed Point–to-Point antenna(s) for this unit must be fixed and mounted on outdoor permanent structures with a separation distance between the antenna(s) of greater than 20cm and a separation distance of at least 100cm from all persons. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 2. Specifications 2.3. Agency compliance information • Furthermore, when using integral antenna(s) the Multinode unit must not be co-located with any other antenna or transmitter device and have a separation distance of at least 20cm from all persons. European Union restriction France restricts outdoor use to 10mW (10dBm) EIRP in the frequency range of 2,454-2,483.5 MHz. Installations in France must limit EIRP to 10dBm, for operating modes utilizing frequencies in the range of 2,454 – 2,483.5MHz. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 2. Specifications 2.4. Honeywell European (CE) Declaration of Conformity (DoC) 2.4 Honeywell European (CE) Declaration of Conformity (DoC) This section contains the European Declaration of Conformity (DoC) statement, for the OneWireless product line. R&TTE Directive 1999/5/EC LVD Directive 73/23/EEC EMC Directive 2004/108/EC ATEX Directive 94/9/EC Harmonized Standards Emissions Specification and Method: EN 300 328 V1.7.1 Emissions Spec and Method: EN 301 893 V1.4.1 Immunity Specification: EN 301 489-17 V1.2.1 Immunity Method: EN 301 489-1 V1.6.1 Product Standard: IEC61326-1 (1st Edition, 2002-02, Industrial Locations) EN 50014:1992, "Electrical Apparatus for Potentially Explosive Atmospheres – General Requirements" EN 50021:1999, "Electrical Apparatus for Potentially Explosive Atmospheres – Type of Protection "n" Manufacturer’s Name and Address Honeywell Process Solutions Compliance Statement The product herewith complies with the harmonized standards listed above. Typical product line systems and configurations have been tested, for compliance. Revision 4 6/24/08 2500 West Union Hills Drive, Phoenix, AZ 85027, USA OneWireless XYR 6000 Pressure Transmitter User's Manual 2. Specifications 2.4. Honeywell European (CE) Declaration of Conformity (DoC) European Declaration of Conformity statements Language Statement Česky (Czech): Honeywell tímto prohlašuje, že tento Multinode je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Dansk (Danish): Undertegnede Honeywell erklærer herved, at følgende udstyr Multinode overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch (German): Hiermit erklärt Honeywell, dass sich das Gerät Multinode in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti (Estonian): Käesolevaga kinnitab Honeywell seadme Multinode vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English Hereby, Honeywell, declares that this Multinode is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español (Spanish): Por medio de la presente Honeywell declara que el Multinode cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική (Greek): ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Honeywell ∆ΗΛΩΝΕΙ ΟΤΙ Multinode ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ Ο∆ΗΓΙΑΣ 1999/5/ΕΚ. Français (French): Par la présente Honeywell déclare que l'appareil Multinode est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Italiano (Italian): Con la presente Honeywell dichiara che questo Multinode è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski (Latvian): Ar šo Honeywell deklarē, ka Multinode atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Lietuvių (Lithuanian): Šiuo Honeywell deklaruoja, kad šis Multinode atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlands (Dutch): Hierbij verklaart Honeywell dat het toestel Multinode in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Malti (Maltese): Hawnhekk, Honeywell, jiddikjara li dan Multinode jikkonforma malħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fidDirrettiva 1999/5/EC. Magyar (Hungarian): Alulírott, Honeywell nyilatkozom, hogy a Multinode megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Polski (Polish): Niniejszym Honeywell oświadcza, że Multinode jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 2. Specifications 2.4. Honeywell European (CE) Declaration of Conformity (DoC) Language Statement postanowieniami Dyrektywy 1999/5/EC. Português (Portuguese): Honeywell declara que este Multinode está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Slovensko (Slovenian): Honeywell izjavlja, da je ta Multinode v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. Slovensky (Slovak): Honeywell týmto vyhlasuje, že Multinode spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi (Finnish): Honeywell vakuuttaa täten että Multinode tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Svenska (Swedish): Härmed intygar Honeywell att denna Multinode står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Íslenska (Icelandic): Hér með lýsir Honeywell yfir því að Multinode er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC. Norsk (Norwegian): Honeywell erklærer herved at utstyret Multinode er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF. For more information about the R&TTE Directive The following website contains additional information about the Radio and Telecommunications Terminal Equipment (R&TTE) directive: http://ec.europa.eu/enterprise/rtte/faq.htm Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 2. Specifications 2.4. Honeywell European (CE) Declaration of Conformity (DoC) Authentication Device Install the Authentication Device application on any PDA having 10 • Windows Mobile version 4.2+ • infrared port. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 3. Preparation 3.1. Installation 3. Preparation 3.1 Installation Refer to the XYR 6000 Transmitter Quick Start Guide (document 34-XY-25-21) for installation, mounting and wiring of your XYR 6000 transmitter. 3.2 Configuration The XYR 6000 Transmitter contains the electronics interface compatible for connecting to the OneWireless network. An operator uses the Wireless Builder application to configure blocks, to change operating parameters, and to create linkages between blocks that make up the transmitter’s configuration. These changes are written to the transmitter when it is authenticated by a security key. 3.3 Connecting to network Use Authentication Device to connect your transmitter to the OneWireless network. See page 24. 3.4 Calibrating the transmitter Overview For all calibration methods, Wireless Builder must be used to unlock and take the channel out of service. You can set the zero offset at the transmitter by use of the infrared port[TWR1]. Additional calibration commands such as upper and lower trim are available in Wireless Builder. Calibrate[RoboHelp2] zero Calibrates the sensor to correct the input measurement due to fill fluid and transmitter position effects once the transmitter is installed and operating under process conditions[H3]. ATTENTION Setting user trim points will effectively override the calibration zero. Normally the calibration zero is only required if you do not intend to provide processspecific trim points. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 11 3. Preparation 3.4. Calibrating the transmitter Table 1 Calibrate zero Step Action Apply zero input pressure for your transmitter’s pressure type as follows. Differential: With process pressure applied, connect HP and LP inputs together using the crossover valve on the 3-valve manifold or other equivalent method. Gauge: Isolate the input pressure from the process and vent to the atmosphere. Absolute: Due to the difficulty of applying absolute 0 psi, zero calibration of the AP transmitter is not recommended. In Wireless Builder, set the transmitter’s Write Lock to Unlocked. In Wireless Builder, set the transmitter’s channel to OOS (Out of Service). At the transmitter, verify the PV value is followed by an out of service (OUT SVC) message. Use Authentication Device’s Device Local Configuration buttons to navigate to the transmitter’s CAL menu. If the transmitter is locked a LOCKED message will be displayed. Go to step 2. If CAL menu is passcode protected, enter the passcode. If the channel is not out of service a WRONG MODE message will be displayed. Go to step 3. 12 Select CAL ZERO. With CAL ZERO displayed, press Enter to set the current applied pressure to zero. If successful the display will briefly show “ZERO SET”. If unsuccessful the display will briefly show “ERROR”. Exit the menu. Reverse step 1. When ready, in Wireless Builder return the transmitter’s channel to service and set Write Lock to Locked. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 4. Function blocks 4.1. Introduction 4. Function blocks 4.1 Introduction This section explains the construction and contents of the XYR 6000 Pressure Transmitter Function Blocks. 4.2 Block description Block types Blocks are the key elements that make up the transmitter’s configuration. The blocks contain data (block objects and parameters) which define the application, such as the inputs and outputs, signal processing and connections to other applications. The XYR 6000 Transmitter contains the following block types. Block Type Function Device Contains parameters related to the overall field device rather than a specific input or output channel within it. A field device has exactly one device block. AITB Contains parameters related to a specific process input or output channel in a measurement or actuation device. An AITB defines a measurement sensor channel for an analog process variable represented by a floating-point value. There is one AITB per sensor. Radio Contains parameters related to radio communication between the transmitter and the multimode(s). Block diagram Figure 2 shows the blocks of the XYR 6000 Transmitter. Transmitter Sensor Analog Input Transducer Block (AITB) Algorithm Device Block OUT Read/ Write Publish Read/ Write Communication Stack Figure 2 Block Diagram Each of these blocks contains parameters that are standard WNSIA-transmitter defined parameters. The AITB and device blocks contain standard parameters common to all XYR 6000 transmitter models (that is, pressure, temperature, DI, corrosion, HLAI) as well as pressure-specific parameters. The radio block contains parameters for communication with the wireless network. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 13 4. Function blocks 4.3. Parameter details 4.3 Parameter details The transmitter itself displays a few basic parameters, such as tag, serial number, device revision, build, device address, WFN ID. For more information on parameters, refer to the following documents. • OneWireless Wireless Builder User’s Guide • OneWireless Builder Parameter Reference [RoboHelp4] 14 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.1. Overview 5. Operation 5.1 Overview Display modes The transmitter has the following display modes. • Test. Appears briefly after power-up to self-test the display. • Connection status. Appears when transmitter is not fully connected to the OneWireless network. See section 5.2. • PV display. Default mode of the transmitter displays the PV and any status messages. See section 5.3 on page 17. • Quick view of transmitter identification parameters. Displays read-only parameters then returns to PV display. See section 5.4 on page 21. • Menu. See section 5.5 on page 22. Authentication Device To navigate the transmitter displays and menus, hold the Authentication Device no more than 6” from the transmitter and aim the infrared beam at the transmitter display while tapping the Device Local Configuration buttons (Table 7). Authentication Device menus are described in section 5.6 starting on page 23. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 15 5. Operation 5.2. Transmitter connection status 5.2 Transmitter connection status Table 2 Transmitter connection status Displayed status Definition What to do NO KEY Transmitter needs a key from the Authentication Device and is not transmitting. Transmit a key to the transmitter. See page 24. NOT CONN Transmitter is in between discovery attempts. If Transmitter does not make a connection within five minutes, do the following: • Check that Key is correct for the network you are trying to join. • Check that Multinode(s) in the local area are turned on and are already a secure part of the network. • Check if KeyServer is active. • Check the KeyServer Event Log to see if the Transmitter is actively trying to join. Errors in the Event Log show that the Transmitter is trying to join but that there are problems. Consult the OneWireless Wireless Builder documentation for troubleshooting errors. DISCOVER Transmitter has not made a connection to a Multinode and is in discovery (searching for a connection to a Multinode). Transmitter will automatically enter a power saving mode if it cannot make a connection and will retry later. Wait for connection. If Transmitter does not make a connection within five minutes, see NOT CONN in this table. SECURING Transmitter has connected with the network and is validating its key. Wait for connection. If Transmitter does not make a connection within five minutes, see NOT CONN in this table. CONNECTD For units with radio firmware build* 53 or higher: For units with radio firmware build* 53 or higher: No action required. Transmitter has validated the key and has made a secure connection with at least two Multinodes. Transmitter should appear in Wireless Builder as an uncommissioned device. For units with radio firmware build* 52: Transmitter will periodically look for a second Multinode in order to form a redundant connection to the network. If connected with only one Multinode Wireless Builder will display a Secondary Multinode Address of 0. For units with radio firmware build* 52: Transmitter has validated the key and has made a secure connection with at least one Multinode. Transmitter should appear in Wireless Builder as an uncommissioned device. NO REDUN Appears only on units with radio firmware build* 53 or higher. No redundancy, that is, Transmitter has connected with only one Multinode. No action required. The Transmitter will periodically look for a second Multinode in order to form a redundant connection to the network *Use the PDA to determine your radio firmware build number (page 21). 16 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.3. Transmitter PV display 5.3 Transmitter PV display In PV display, the following information is displayed in sequence. Item displayed Example Details PV value +14.7 Latest PV value. PV engineering units PSI See Table 3. PV status BAD See Table 4. If PV status is not displayed then the PV value is good. Device status LOW BATT See Table 5. If multiple device status messages are in effect, they are displayed one message per channel until all messages have been displayed. If no device status is displayed then the device status is normal. Table 3 PV engineering units Engineering units Revision 4 6/24/08 Description MPa milliPascals kPa kilopascals bar Bars mbar Millibars PSI Pounds per square inch G/CM2 Grams per square centimeter KG/CM2 Kilograms per square centimeter INH2O 4C Inches of water at 4° C INH2O 68F Inches of water at 68°F MMH2O 4C Millimeters of water at 4°C MMH2O 68F Millimeters of water at 68° F INHG 0C Inches of mercury at 0° C MMHG 0C Millimeters of mercury at 0° C PERCENT Percent OneWireless XYR 6000 Pressure Transmitter User's Manual 17 5. Operation 5.3. Transmitter PV display Table 4 PV status PV status Cause - Action (blank) • PV is normal – no action required BAD • Possible calibration error – Clear calibration • AITB can not execute due to internal firmware state – Attempt cold restart of device. • AITB can not execute due to hardware fault – Replace sensor board • Sensor failure – Check Connection between Sensor board and Meter Body. • Meter Body Characterization Data is Bad – Replace Meter Body • Meter Body A/D Failure – Replace Meter Body • Meter Body Sensor Fail – Replace Meter Body BAD CONFIG • BAD E FAIL • UNC • Configuration is bad – Check possible units and range settings for input type and correct AITB configuration. Hardware fault detected - Replace sensor board Warning: Calibration (zero or trim) is causing excessive adjustment to characterization value. • Warning: Input inaccurate due to uncertain input data integrity. • Warning: Input inaccurate due to input conversion limitations or resolution. • Warning: Input outside of characterized range. Value is estimated. Table 5 Device status Transmitter display 18 Wireless Builder display Definition What to do OUT SVC OOS All channels are out of service. Restore mode to Auto in Wireless Builder. SENS ERR Sensor Error Sensor can not access meter body A/D converter. Check connection between sensor module and meter body. If still doesn't work, replace sensor. See page 33. CHAR ERR Characterization Error Sensor can not access meter body characterization or the characterization is invalid. Check connection between sensor module and meter body. If still doesn't work, replace sensor. See page 33. OVR TEMP Over Temperature The meter body has exceeded the maximum temperature as defined by the meter body characterization data. Determine cause excessive temperature. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.3. Transmitter PV display Transmitter display Wireless Builder display Definition What to do OVR LOAD Over Load The applied pressure has exceeded the limit defined by the meter body characterization data. Determine cause of over pressure. CAL ERR Calibration Error Calibration Data Invalid or could not be read. Use Cal Clear, Restore, or User Calibrate. CFG ERR Configuration Error Configuration Check Error. Database is corrupted. Cold start and reload configuration. LOW BAT Low Battery Battery Voltage Critically Low Replace batteries as soon as possible. See page 35. NO RADIO Radio Interprocessor Comm Error Radio Board is not accessible. Restart both the radio and sensor. If condition persists, replace sensor module. See page 33. CHAR ERR Characterization Error Startup Diagnostics detected error in Meter Body Characterization Data Check connection between meter body and sensor module. Replace meter body if conditions persist. OVR TEMP Over Temperature Meter Body detected over temperature. The meter body is being subjected to temperatures above the specified operational range. Correct over-temperature condition. OVR LOAD Over Load Meter Body detected Pressure Overload The meter body is being subjected to pressure above the specified operational range. Correct overpressure condition. BAD RADIO SPI Sensor Radio SPI Communication Failure Radio detected loss of communication with sensor board over the inter-processor communication link. Restart both the radio and sensor. If condition persists, replace sensor module. See page 33. BAD RADIO EEPROM EEPROM SPI Communication Failure Radio EEPROM SPI Communication failure The radio will not be able to perform firmware upgrades but will operate normally using installed code. Replace sensor module. See page 33. RADIO WDT RESET WDT Reset Occurred Radio Watch Dog Timeout detected Restart both the radio and sensor. If condition persists, replace sensor module. See page 33. BAD RADIO Radio Circuitry Failure Radio circuitry has failed The radio processor detected error on internal radio circuitry. Replace sensor module. See page 33. The following status messages have multiple meanings. Refer to Wireless Builder Device Status for exact cause. INP FAIL Revision 4 6/24/08 Input Failure Input Error Possible meter body sensor failure. OneWireless XYR 6000 Pressure Transmitter User's Manual 19 5. Operation 5.3. Transmitter PV display Transmitter display Wireless Builder display Definition What to do INP FAIL A/D Failure Diagnostics detected defect with Analog to Digital Converter. Replace sensor module. See page 33. E FAIL A/D Failure Diagnostics detected defect with Analog to Digital Converter. Replace sensor module. See page 33. E FAIL Electronics Failure Electronic Failure detected on Sensor Board. Could be caused by one of the status items marked by *. Restart both the radio and sensor. If condition persists, replace sensor module. See page 33. E FAIL* NVM Fault* Startup diagnostics detected defect in Sensor Non-Volatile Memory Replace sensor module. See page 33. E FAIL* Program Memory Fault* Startup diagnostics detected defect in Sensor Read Only Memory Replace sensor module. See page 33. E FAIL* RAM Fault* Startup diagnostics detected defect in Processor Random Access Memory Replace sensor module. See page 33. The following statuses are displayed only in Wireless Builder Device Status. blank Excess Zero Calibration The selected zero offset or the lower calibration trim point is beyond 5% of the lower end of the characterized range of the device. Clear Calibration blank Excess Span Calibration The calibrated upper and lower trim has produced a span that is greater than 5% of the characterized span of the transmitter. Clear Calibration Or Set Factory Calibration Or Check the applied trim points and re-attempt lower and upper (trim) calibration. blank 20 Excess Calibrated Range The selected calibration points used for upper and lower trim are outside the characterized range of the transmitter. Check that the upper and lower trim points are both within the characterized range of the transmitter and re-attempt upper and lower (trim) calibration. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.4. Transmitter quick view of parameters Transmitter display blank Wireless Builder display Calibration Cleared Definition What to do Indicates that both the upper and lower trim points as well as the zero offset has been cleared. The calibration source is none. Select Factory Calibration Or Calibration the zero offset Or Calibrate using the lower and upper trim points. blank* Device/Firmware Mismatch* Sensor Board Firmware Error. The software did not pass verification tests. Replace sensor module. See page 33. blank* Heap Memory Not Available* Heap Allocation Failure. Software detected heap shortage and some communication packets may have been dropped. Clear by warm restart of device. If condition persists contact Honeywell service. blank* Watchdog Timer Error* Sensor Watchdog Timeout. The processor was restarted due to unexpected operation. Clear by warm restart of device. If condition persists contact Honeywell service. 5.4 Transmitter quick view of parameters If you press the up or down arrow key during the PV display, the following quick view parameters are shown sequentially, then the PV display resumes. Parameter Revision 4 6/24/08 Description Transmitter type HONEYWELL XYR 6000 PRESSURE Tag The name given to this transmitter Serial number Transmitter serial number. This is the WBSN on the transmitter’s nameplate. Do not confuse this with the other nameplate item marked “Serial.” Device revision This parameter changes whenever objects and parameters are added, deleted, or the data type or range changes. It does not change if the application firmware changes without affecting the device description. Build Sensor firmware number MB Serial number Meter body serial number OneWireless XYR 6000 Pressure Transmitter User's Manual 21 5. Operation 5.5. Transmitter menu 5.5 Transmitter menu Menu tree At the PV display, press Enter to access the menus. To interact with the menus use the Device Local Configuration onscreen buttons (page 26) or the buttons on your PDA. Table 6 Menu tree Menu item Description CAL Calibration menu. May be password-protected. See Table 7 on page 26 for password number entry. CAL ZERO RADIO Radio menu PRI RSSI 22 Calibrate zero. See page 11. Primary receive signal strength. Read only. Signal strength 00 is too weak to connect to the network. Displayed Value Value dBm Rx Margin dB 00 < -86 < 10 01 -86 to -81 10 to 15 02 -80 to -75 16 to 21 03 -74 to -69 22 to 27 04 -68 to -63 28 to 33 05 -62 to -57 34 to 39 06 -56 to -51 40 to 45 07 -50 to -45 46 to 51 08 -44 to -11 52 to 85 09 ≥ -10 Saturation SEC RSSI Secondary receive signal strength. Same as PRI RSSI. Read only. WFN ID Wireless Field Network ID. Read only. DEV ADD Device address. Read only. TX POWER Radio transmit power. Read only. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.6. Authentication device menus 5.6 Authentication device menus Overview Hold the Authentication Device no more than 6” from the transmitter and aim the infrared beam at the transmitter display while tapping on the screen command or button. Main menu The main menu is shown below. Details start on the next page. Figure 3 Main menu Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 23 5. Operation 5.6. Authentication device menus Security and Node Deployment Use this to: • receive new security keys, • transmit security keys for connecting the transmitter (or other nodes) to the OneWireless network, • clear all security keys from the PDA, • clear the transmitter’s key and reset its configuration to factory default (such as for decommissioning). Figure 4 Security and Node Deployment 24 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.6. Authentication device menus To connect your transmitter to the OneWireless network perform the following steps. Step Action If the PDA contains no keys, obtain new security keys from the PC application Key Server Manager. To do this, select Receive Security Keys. Keys can be received either through Infrared (by aiming PDA at the infrared dongle) or through an ActiveSync/USB connection. See Key Server Communication Method under Advanced options on page 29 for details. Important: The Comm Method settings must match in the PC’s Key Server Manager and in the Authentication Device (both must be set to Infrared or both to ActiveSync) in order for your PDA to receive security keys. See Key Server Communication Method under Advanced options on page 29 for details. When the Authentication Device has valid unexpired keys, aim it at the transmitter and transmit a key to the transmitter. The transmitter will validate the key and then use it to make a connection to the OneWireless Network. The Transmitter may continue to show the diagnostic message “NO KEY” for a brief time while it validates the key before showing the “DISCOVER” message. To verify your transmitter has been authenticated, see the Connection prompt on the Read Node Info screen (page 27). To decommission your transmitter from the OneWireless network, select Clear Key and Restart Node. This clears the transmitter’s key, network and security configurations, and resets the transmitter to its factory default settings. perform the following steps. Select Clear Keys from Handheld (under Advanced Options) when: • The PDA has keys from one system, but you have moved your Authentication Device to another system, or • you want to clear all keys so that you cannot deploy any more keys without going to the key server manager and getting more. For more details on keys, refer to Getting Started with Honeywell OneWireless Solutions. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 25 5. Operation 5.6. Authentication device menus Device Local Configuration Use Device Local Configuration buttons (Table 7) to navigate the transmitter menus (Table 6) and to make selections and changes. You can also use the PDA buttons. Figure 5 Device Local Configuration screen Table 7 Buttons for Device Local Configuration Button Function • Enter the Menu Tree. • Enter submenu of the menu that is appearing on the screen. • Execute action. • Submit the entered number while doing number entry. • Read value of certain displayed parameters. • Go to the next menu in the same level. • View quick view parameters in Normal Display Sequence (PV Display). • During number entry, increment the digit or change +/- sign. • Go to the previous menu in the same level. • View quick view parameters in Normal Display Sequence (PV Display). • During number entry, decrement the digit or change +/- sign. • Go to the upper menu level. • When changing a number value, move cursor to the left/more significant digit, then wrap around to the least significant digit. 26 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.6. Authentication device menus Read Node Information Use this to read the transmitter information shown in Figure 6. Similar to quick view parameters on the transmitter display. (See page 21.) Figure 6 Read Node Information Item Description Tag The name given to this transmitter Serial Transmitter serial number. This is the WBSN on the transmitter’s nameplate. Do not confuse this with the other nameplate item marked “Serial.” NwAddr Network Address of the device in hexadecimal. DevRev Device Revision. This parameter changes whenever objects and parameters are added, deleted, or their data type or range changes. It does not change if the application firmware changes without affecting the device description. Range: 0 to 65535. Build Sensor firmware and radio firmware build numbers. Radio Hardware radio type, FHSS or DSSS WFN ID: Wireless Field Network ID. Range: 0 to 255. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 27 5. Operation 5.6. Authentication device menus Item FH Mode Description Frequency group or frequency channel selection used by the wireless network of the device. The value must match the value set in the gateway and interface nodes to allow communication between the device and the wireless network. Modes: US Channel #1 US Channel #6 US Channel #11 US Guard Bands EU Channel #1 EU Channel #7 EU Channel #13 EU Guard Bands US/EU Spec Div A US/EU Spec Div B US/EU Channel #3 US/EU Channel #10 Complete Spectrum Connection The first line displays one of the following connection states. No Security Key – No security key has been deployed to the device or multinode. The user must give a security key to the device or multinode before it will join the wireless sensor network. No Connection – A security key exists in the device or multinode, but no connection has been formed. The device or multinode is waiting to form a connection and will automatically retry shortly. Users may transmit a new security key in order to force the device or multinode to immediately retry to form a connection. Discovering – The device is attempting to form a connection to the wireless sensor network. The device is discovering multinodes and, if a multinode is found, will transition to the securing state. Securing – The device is attempting to form a connection to the wireless sensor network. The device has discovered one or two multinodes and is attempting to form a secure session. If successful, the device will transition to the connected state. Connected – A secure connection is formed with one or two multinodes. The second line contains detailed state information useful for problem reporting. 28 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 5. Operation 5.6. Authentication device menus Advanced Options Advanced options are non-typical configuration commands. Figure 7 Advanced Options Table 8 Advanced Options Item Description Key Server Communication Method Determines how the PDA will receive security keys from the PC’s Key Server Manager application. From the Comm Method menu select one of the following methods. ActiveSync – Select this to receive keys over a USB connection, such as while the PDA battery is being charged in its base. Infrared – Select this to receive keys over the infrared port. Important: The Comm Method settings match in the PC’s Key Server Manager and in the Authentication Device (both must be set to Infrared or both to ActiveSync) in order for your PDA to receive security keys. Read Tracelog Flag Not available for transmitters. Used with multinodes. Reads conditional tracelog flag value. Tracelog flags are used to enable and disable logging functionality used for field support. Write Tracelog Flag Not available for transmitters. Used with multinodes. Writes conditional tracelog flag value. Tracelog flags are used to enable and disable logging functionality used for field support . Select Infrared Communication Port Overrides the detected infrared communication port detected on your PDA. If infrared communication is not functioning, you can override the detected settings using this option. Read TX Power Level Reads the transmission power level of the transmitter radio. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 29 6. Maintenance/Repair 6.1. Introduction 6. Maintenance/Repair 6.1 Introduction This section provides information about preventive maintenance routines and replacing damaged parts. The topics covered in this section are: Preventive maintenance of the meter body barrier diaphragms and process piping to the transmitter. Replacement of damaged parts such as the transmitter display/sensor and batteries. 6.2 Preventive maintenance The XYR 6000 transmitter itself does not require any specific maintenance routine at regularly scheduled intervals. However, you should consider carrying out these typical inspection and maintenance routines on a schedule that is dictated by the characteristics of the process medium being measured and whether blowdown facilities or purge systems are being used. Check piping for leaks. Clear the piping of sediment or other foreign matter. Clean the transmitter’s pressure chambers including the barrier diaphragms. 6.3 Inspecting and cleaning barrier diaphragms Depending on the characteristics of the process medium being measured, sediment or other foreign particles may collect in the process head cavity/chamber and cause faulty measurement. In addition, the barrier diaphragm or diaphragms in the transmitter’s meter body may become coated with a residue from the process medium. The latter is also true for external diaphragms on flange mount and remote seal type transmitters. In most cases, you can readily remove the process head or heads from the transmitter’s meter body to clean the process head cavity and inspect the barrier diaphragm or diaphragms. For flange mount and remote seal diaphragms, you may only need to run a purge line in the tank to rinse off the face of the diaphragm. The procedure in Table 9 outlines the general steps for inspecting and cleaning barrier diaphragms. You may have to modify the steps to meet your particular process or transmitter model requirements. Figure 8 shows an exploded view of a DP transmitter’s meter body for reference. WARNING Risk of death or serious injury by explosion. Do not open transmitter enclosure when an explosive gas atmosphere is present. Tools required 30 • 5/8” Wrench or Socket for 7/16” Dia. Hex Bolt • 3/4” Wrench or Socket for 7/16” Hex Nut • Calibrated torque wrench. For the most accurate performance, select a torque wrench with which the applied torque value is near the middle of the tool’s torque range. For example, if applying 68 N-M (50 Lb-Ft), select a torque wrench with range of 7 N-M to 136 N-M (5 to 100 Lb-Ft). OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.3. Inspecting and cleaning barrier diaphragms Procedure Table 9 Inspecting and Cleaning Barrier Diaphragms Step Action Close all valves and isolate transmitter from process. Open vent in process head to drain fluid from transmitter’s meter body, if required. ATTENTION We recommend that you remove the transmitter from service and move it to a clean area before taking it apart. WARNING Risk of death or serious injury by explosion. Do not open transmitter enclosure when an explosive gas atmosphere is present. Remove nuts from bolts that hold process head or heads to meter body. Remove process heads and bolts. See Figure 8. Remove gasket and clean interior of process head using soft bristle brush and suitable solvent. CAUTION Diaphragm surface is fragile. Be very gentle, do not damage. Inspect barrier diaphragm for any signs of deterioration or corrosion. Look for possible residue and clean if necessary. If diaphragm is dented, has distorted convolutions or radial wrinkles, performance may be affected. Contact Honeywell for assistance. Replace process head gasket. ATTENTION • We recommend that you install a new gasket whenever a process head is removed for cleaning. For process heads of a GP or AP transmitter with dual-head design, see illustration for differential pressure transmitters in Figure 8. Revision 4 6/24/08 Coat threads on process head bolts with anti-seize compound such as “Neverseize” or equivalent. Replace process head or heads and bolts. Finger tighten nuts. Use a torque wrench to gradually tighten nuts to torque rating shown in Table 10, in sequence shown in Figure 8. Tighten head bolts in stages of 1/3 full torque, 2/3 full torque, and then full torque. Return transmitter to service. OneWireless XYR 6000 Pressure Transmitter User's Manual 31 6. Maintenance/Repair 6.3. Inspecting and cleaning barrier diaphragms Tighten in sequence shown Figure 8 Assembly of DP Transmitter Process Heads Torque ratings Table 10 lists process head bolt torque ratings for given transmitter type. Table 10 Process Head Bolt Torque Ratings Bolt Type 7/16 x 14 UNC Meterbody Type 50019775XXXX 51452557-001 (Carbon Steel - standard; no option specified) 51452557-002 and –003 (NACE [“CR” option], NonNACE [“SS” option] 316 Stainless Steel) 51452557-004 (B7M Alloy Steel [“B7” option]) 67,8 N•M +/- 3,4 N•M (50.0 Lb-Ft +/- 2.5 Lb-Ft) 56,9 N•M +/- 2,8 N•M (42.0 Lb-Ft +/- 2.1 Lb-Ft) 48,8 N•M +/- 2,4 N•M (36.0 Lb-Ft +/- 1.8 Lb-Ft) [RoboHelp5] 32 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.4. Replacing sensor module 6.4 Replacing sensor module Tools required • #1 Phillips Screwdriver or 1/8” Slotted Screwdriver • Torque Screwdriver • 1.5 mm hex key Procedure WARNING Risk of death or serious injury by explosion. Do not open transmitter enclosure when an explosive gas atmosphere is present. CAUTION Take precautions against electrostatic discharge to prevent damaging the sensor module. Table 11 Sensor module replacement Step Action Honeywell recommends that the transmitter be removed from service and moved to a clean area before servicing. Loosen the M3 locking set screw on the display end-cap. See item 1 in Figure 9. Unscrew and remove the end cap. Loosen the two screws on the sensor module. See items 2 in Figure 9. Disconnect each connector on the sensor module. See items 3 in Figure 9. Install new sensor module. Be sure to orient sensor module in the proper viewing orientation before tightening two sensor compartment screws. Reverse steps 1-4. Torque screws to 0,4 – 0,6 N-M (3.5 – 5.3 Lb-in). Honeywell recommends lubricating the end cap O-ring with a Silcone Grease such as Dow Corning #55 or equivalent before replacing the end cap. Return transmitter to service. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 33 6. Maintenance/Repair 6.4. Replacing sensor module Figure 9 Sensor module removal and replacement 34 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.5. Replacing batteries 6.5 Replacing batteries When to replace When the transmitter displays a LO BATT message you have 2-4 weeks to replace both batteries before they expire. When batteries are removed or expired, all transmitter data is retained in the transmitter’s nonvolatile memory. Tools required • #1 Phillips Screwdriver or 1/8” Slotted Screwdriver • Torque Screwdriver • 1.5 mm hex key Procedure ATTENTION Batteries must be replaced only by a trained service technician. WARNINGS • Risk of death or serious injury by explosion. Do not open transmitter enclosure when an explosive gas atmosphere is present. • Batteries must not be changed in an explosive gas atmosphere. • The batteries used in this device may present a risk of fire or chemical burn if mistreated. Do not recharge, disassemble, heat above 100°C (212°F), or incinerate. Table 12 Battery replacement procedure Step Action ATTENTION You must replace both batteries. Both batteries must be the same model from the same manufacturer. Mixing old and new batteries or different manufacturers is not permitted. Use only the following 3.6V lithium thionyl chloride (Li-SOCl2) batteries (non-rechargeable), size D. No other batteries are approved for use in XYR 6000 Wireless Transmitters. Revision 4 6/24/08 • Xeno Energy XL-205F • Eagle Picher PT-2300H • Tadiran TL-5930/s • Honeywell p/n 50026010-001 (Two 3.6V lithium thionyl chloride batteries) (1 transmitter) • Honeywell p/n 50026010-002 (Four 3.6V lithium thionyl chloride batteries) (2 transmitters) • Honeywell p/n 50026010-003 (Ten 3.6V lithium thionyl chloride batteries) (5 transmitters) Loosen the M3 locking set screw on the battery end-cap (opposite end from display). See item 1 in Figure 10. Unscrew and remove the end cap. OneWireless XYR 6000 Pressure Transmitter User's Manual 35 6. Maintenance/Repair 6.5. Replacing batteries Step Action Using thumb and forefinger, squeeze the battery connector at top and bottom to disengage the locking mechanism, then pull to disconnect. See item 2 in Figure 10. Loosen the two battery holder retaining screws (closest to the batteries). See item 3 in Figure 10. The screws are captive. Pull the battery holder out of the transmitter. Remove the old batteries from the battery holder. If needed, pry out the batteries by using a slotted screwdriver as a lever in the holder’s side slots. See item 4 in Figure 10. Insert the new batteries using correct polarity shown on the battery holder. Insert the battery holder into the transmitter. Reattach the screws and tighten to 0,4 – 0,6 N-M (3.5 – 5.3 Lb-in). Re-connect battery connector. Honeywell recommends lubricating the end cap O-ring with a Silcone Grease such as Dow Corning #55 or equivalent before replacing the end cap. Screw the end cap back on and tighten the M3 locking screw. Dispose of used battery promptly per local regulations or the battery manufacturer’s recommendations. Keep away from children. Do not disassemble and do not dispose of in fire. Figure 10 Battery replacement 36 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.6. Replacing antenna 6.6 Replacing antenna Tools required • #1 Phillips Screwdriver or 1/8” Slotted Screwdriver • Torque Screwdriver • 1.5 mm hex key Procedure ATTENTION You must replace your antenna with the same type, that is, elbow, straight, or remote. Changing to a different antenna type is not permitted by approval agencies. CAUTION Take precautions against electrostatic discharge to prevent damaging the sensor module. WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD The integrally mounted antenna shroud is made of Teflon® and has a surface resistance greater than 1Gohm per square. When the XYR 6000 transmitter is installed in potentially hazardous locations care should be taken not to electrostatically charge the surface of the antenna shroud by rubbing the surface with a cloth, or cleaning the surface with a solvent. If electrostatically charged, discharge of the antenna shroud to a person or a tool could possibly ignite a surrounding hazardous atmosphere. Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 37 6. Maintenance/Repair 6.6. Replacing antenna Table 13 Antenna replacement procedure Step 38 Action Honeywell recommends that the transmitter be removed from service and moved to a clean area before servicing. Loosen the M3 locking set screw on the display end-cap. See item 1 in Figure 11. Unscrew and remove the front end cap. Loosen the two screws on the sensor module. See items 2 in Figure 11. Remove the sensor module from the transmitter body and disconnect the antenna connector from CN2 connector on the sensor module. See item 3 in Figure 11. Loosen the locking set screw at the antenna base. Unscrew the antenna from the transmitter. Remove the antenna and its connector from the transmitter. See Figure 11. Feed the new antenna’s connector through the antenna hole to the front of the transmitter. Do not connect to sensor module yet. Lubricate O-ring with a Silicone Grease such as Dow Corning #55Screw new antenna into transmitter body until finger-tight, then back off 180 degrees to permit adjustment later. Attach antenna connector to CN2 connector on sensor module. See item 3 in Figure 11. Insert sensor module. Orient in the proper viewing orientation before tightening two sensor compartment screws. See items 2 in Figure 11. Torque screws to 0,4 – 0,6 N-M (3.5 – 5.3 Lbin). Replace the front end cap. Honeywell recommends lubricating the front end cap O-ring with a Silcone Grease such as Dow Corning #55 or equivalent before replacing the end cap. 10 Adjust antenna for best reception. Don’t rotate antenna more than 180 degrees either direction or you could twist and break the antenna wiring inside. Tighten the antenna locking set screw. OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.7. Parts Antenna connector Figure 11 Antenna replacement 6.7 Parts Transmitter body The following replacement parts may be ordered from Honeywell. Part number Qty. Description 50015866-502 ELECTRONICS MODULE ASSEMBLY aka SENSOR MODULE for Pressure 50015866-506 ELECTRONICS MODULE ASSEMBLY aka SENSOR MODULE for PressureInstrinsically Safe 50015866-510 ELECTRONICS MODULE ASSEMBLY aka SENSOR MODULE for Pressure-DSSS Intrinsically Safe 50015843-501 TERMINAL BOARD Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 39 6. Maintenance/Repair 6.7. Parts Part number Qty. Description 50015623-501 CAP ASSEMBLY, BATTERY, ALUMINUM, DARK BEIGE 50016190-501 CAP ASSEMBLY, LCD, ALUMINUM, DARK BEIGE 50026009-501 CAP ASSEMBLY, BATTERY, STAINLESS STEEL 50026127-501 CAP ASSEMBLY, LCD, STAINLESS STEEL 50016229-501 ANTENNA ASSEMBLY, 2 dBi INTEGRAL RIGHT-ANGLE, ALUMINUM 50016229-502 ANTENNA ASSEMBLY, 2 dBi INTEGRAL RIGHT-ANGLE, STAINLESS STEEL 50020767-501 ANTENNA ASSEMBLY, 2 dBi INTEGRAL STRAIGHT, STAINLESS STEEL 50020767-502 ANTENNA ASSEMBLY, 2 dBi INTEGRAL STRAIGHT, ALUMINUM 50031714-501 ANTENNA ASSEMBLY, 4 dBi INTEGRAL STRAIGHT, STAINLESS STEEL 50031714-502 ANTENNA ASSEMBLY, 4 dBi INTEGRAL STRAIGHT, ALUMINUM 50031715-501 ANTENNA ASSEMBLY, 4 dBi INTEGRAL RIGHT-ANGLE, ALUMINUM 50031715-502 ANTENNA ASSEMBLY, 4 dBi INTEGRAL RIGHT-ANGLE, STAINLESS STEEL 50018414-001 REMOTE OMNI-DIRECTIONAL ANTENNA, 8 dBi 50018415-001 REMOTE DIRECTIONAL ANTENNA, 14 dBi 50016577-501 ANTENNA ADAPTER ASSEMBLY, REMOTE, TYPE TNC, STAINLESS STEEL 50016577-502 ANTENNA ADAPTER ASSEMBLY, REMOTE, TYPE TNC, ALUMINUM 50028364-501 ANTENNA ADAPTER ASSEMBLY, REMOTE, TYPE N, ALUMINUM 50028364-502 ANTENNA ADAPTER ASSEMBLY, REMOTE, TYPE N, STAINLESS STEEL 50018110-001 COAX CABLE ASSY, 1.0M ( 3.3 Ft) LONG, RP-TNC - N-MALE 50018110-002 COAX CABLE ASSY, 3.0M (10.0 Ft) LONG, RP-TNC - N-MALE 50018110-003 COAX CABLE ASSY, 10.0M (33.0 Ft) LONG, RP-TNC - N-MALE 50018278-001 COAX CABLE ASSY, 1.0M ( 3.3 Ft) LONG, N-MALE - N-MALE 50018278-002 COAX CABLE ASSY, 3.0M (10.0 Ft) LONG, N-MALE - N-MALE 50018278-003 COAX CABLE ASSY, 10.0M (33.0 Ft) LONG, N-MALE - N-MALE 50018279-090 LIGHTNING SURGE ARRESTOR 50025288-001 BATTERY HOLDER, PRESSURE 50025288-002 BATTERY HOLDER, TEMPERATURE, HLAI, CORROSION 50026010-001 3.6V LITHIUM THIONYL CHLORIDE (Li-SOCI2) BATTERY 50026010-002 3.6V LITHIUM THIONYL CHLORIDE (Li-SOCI2) BATTERY 50026010-003 10 3.6V LITHIUM THIONYL CHLORIDE (Li-SOCI2) BATTERY continued 40 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.7. Parts Meter body Use the following figures and table to find replacement parts. Figure 12 STDW924, STDW930, STDW974 Figure 13 STGW944, STGW974 Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 41 6. Maintenance/Repair 6.7. Parts Table 14 Parts (see Figure 12, Figure 13) Key No. Part Number Description Specify complete model number from nameplate Specify complete model number from nameplate Qty/ Unit Series 100 Meter Body replacement kit includes: Meter body (without Process Heads) Neoprene O-ring, Meter Body to Electronic Housing (K7; Part no. 30752785-009; 1/unit) Process Head Gasket; PTFE (K6; Part No. 51452560-002; 2/unit) Series 900 Meter Body replacement kit includes: Meter body (without Process Heads) Neoprene O-ring, Meter Body to Electronic Housing (K7; Part no. 30752785-009; 1/unit) Process Head Gasket; PTFE (K6; Part No. 51452560-002; 2/unit) Bolting Kits: 51452866-001 Bolts and Nuts Kit, Carbon Steel 51452866-002 Bolts A286 SS (NACE) and Nuts, 304 SS (NACE) Kit 51452866-003 Bolts, 316 SS (non-NACE) and Nuts, 316 SS (non-NACE) Kit 51452866-004 Bolts B7M and Nuts 7M Kit Each Bolts and Nuts Kit includes: Kc ································ Bolt, Hex head, 7/16-20 UNF, 1.50 Inches long (Flange Adapter)········ K4 ································ Nut, Hex, 7/16 UNC (Process Head)···················································· K8 ································ Bolt, Hex Head, 7/16 UNC X 3.25 inches long (Process Head)············ Vent and Plug Kits: 30753785-001 Drain and Plug Kit, stainless steel 30753787-001 Drain and Plug Kit, Monel 30753786-001 Drain and Plug Kit, Hastelloy C Each Drain and Plug Kit includes: K1 ································ Pipe Plug ···················································································· K2 ································ Vent Plug ····························································································· K3 ································ Vent Bushing ······················································································· Meterbody Gasket Kits: Meterbody Gasket Kit (PTFE Material); Kit includes: 51452865-002 Meterbody Gasket Kit (Viton Material); Kit includes: K6 ································· Gasket, Process Head ········································································· Ka ································· Gasket, Flange Adapter ······································································· ································· O-Ring, Meterbody to Electronics Housing ·········································· K7 42 51452865-001 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.7. Parts Key No. Part Number Description Qty/ Unit Process Head Gasket Kits: K6 51452868-001 Gasket only, Process Head (12 PTFE Gaskets/pack) 12 K6 51452868-002 Gasket only, Process Head (6 Viton Head O-Rings) K6 51452868-007 Gasket only, Process Head Graphite Gasket (use only as replacement of existing graphite gasket) Flange Adapter Gasket Kits: Ka 51452868-004 Gasket only, Flange Adapter, 6 PTFE Adapter Gaskets Ka 51452868-005 Gasket only, Flange Adapter, 6 VITON Adapter O-Rings Ka 51452868-078 Gasket only, Flange Adapter Graphite Gasket (use only as replacement of existing graphite gasket) ½ inch NPT Flange Adapter Kits: Flange Adapter Kit, with: 51452867-110 SS Flange Adapters and with carbon steel bolts 51452867-210 SS Flange Adapters and with A286 SS (NACE) bolts 51452867-310 SS Flange Adapters and with 316 SS (non-NACE) bolts 51452867-410 SS Flange Adapters and with B7M alloy steel bolts 51452867-150 Monel Flange Adapters and with carbon steel bolts 51452867-350 Monel Flange Adapters and with 316 SS (non-NACE) bolts 51452867-130 Hastelloy C Flange Adapters and with carbon steel bolts 51452867-330 Hastelloy C Flange Adapters and with 316 SS (non-NACE) bolts Each 1/2-inch NPT Flange Adapter Kit includes: ··································· Gasket, Flange Adapter ································································ Kb ··································· 1/2-inch NPT Flange Adapter ························································· Kc ··································· Bolt, hex head, 7/16-20 UNF, 1.50 inches long, Flange Adapter ·· Ka Blind Flange Adapter Kits: 51452867-100 SS Blind Flange Adapter Kit, with Carbon Steel bolts 51452867-200 SS Blind Flange Adapter Kit, with A286 SS (NACE) bolts 51452867-300 SS Blind Flange Adapter Kit, with 316 SS (non-NACE) bolts 51452867-400 SS Blind Flange Adapters and B7M alloy steel bolts Each Blind Flange Adapter Kit includes: ··································· Gasket, Flange Adapter ································································ Kb ··································· Blind Flange Adapter ······································································ Kc ··································· Bolt, hex head, 7/16-20 UNF, 1.50 inches long, Flange Adapter ·· Ka Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 43 6. Maintenance/Repair 6.7. Parts Key No. Part Number Description Qty/ Unit Process Head Kits: K1 K2 K3 K5 K6 Ka 51452864-010 51452864-012 Process Head Assembly Kit, with PTFE Gasket and with: Carbon steel head (zinc plated) without side vent/drain Carbon steel head (zinc plated) with side vent/drain 51452864-020 51452864-022 Stainless steel head without side vent/drain Stainless steel head with side vent/drain 51452864-030 51452864-032 Hastelloy C head without side vent/drain Hastelloy C head with side vent/drain 51452864-040 51452864-042 Monel head without side vent/drain Monel head with side vent/drain 51452864-050 51452864-052 Carbon steel head (nickel plated) without side vent/drain Carbon steel head (nickel plated) with side vent/drain 51452864-110 51452864-112 Process Head Assembly Kit, with VITON Gasket and with: Carbon steel head (zinc plated) without side vent/drain Carbon steel head (zinc plated) with side vent/drain 51452864-120 51452864-122 Stainless steel head without side vent/drain Stainless steel head with side vent/drain 51452864-130 51452864-132 Hastelloy C head without side vent/drain Hastelloy C head with side vent/drain 51452864-140 51452864-142 Monel head without side vent/drain Monel head with side vent/drain 51452864-150 51452864-152 Carbon steel head (nickel plated) without side vent/drain Carbon steel head (nickel plated) with side vent/drain ··································· ··································· ··································· ··································· ··································· ··································· Each Process head Assembly Kit includes: Pipe Plug (See Note 1, 2.)····························· ········································ Vent Plug (See Note 1.)···················································· ····················· Vent Bushing (See Note 1.)························································ ··········· Process Head ························································································ Gasket (PTFE), Process Head ······························································ Gasket (PTFE), Flange Adapter····························································· NOTE 1 : This item is made of the same material as the Process Heads, except for Kits with carbon steel Process Heads, which include stainless steel Pipe Plug, Vent Plug, and Vent Bushing. NOTE 2: The Kit for Process Heads without side vent/drain does not include Pipe Plugs (K1). Reference Head: K9 K9 44 51452951-001 51452951-002 Carbon Steel Blind Reference Head 316 SS Blind Reference Head (Model Selection Guide HR Option) OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.7. Parts Figure 14 STGW94L, STGW97L, STGW987L, STAW94L Table 15 Parts (see Figure 14) Key No. K7 Part Number Description Specify complete model number from nameplate Meter Body replacement kit includes: 30757503-001 Electronics enclosure seals kit for LGP/LAP models. Kit includes: Meter body Qty/ Unit ……..…….…………… O-ring for transmitter end caps ………………………… O-ring, meter body to electronics housing Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 45 6. Maintenance/Repair 6.8. Dimension drawings 6.8 Dimension drawings Dimension drawings are available for each transmitter model. If you need a copy of a drawing, please determine the appropriate drawing number from the following tables and contact your Honeywell representative. Table 16 Drawing numbers for DP models STDW924, STDW930, STDW974 Angle Bracket (“MB” or “SB”) Flat Bracket (“FB”) Vertical Pipe Vertical Pipe Horizontal Pipe 50022275 50022274 50022273 Horizontal Pipe 50022272 Table 17 Drawing numbers for DHGP models STGW944, STGW974 Angle Bracket (“MB” or “SB”) Flat Bracket (“FB”) Vertical Pipe Vertical Pipe 50022279 Horizontal Pipe 50022278 50022277 Horizontal Pipe 50022276 Table 18 Drawing numbers for GP/AP models STGW94L, STGW97L, STGW98L, STAW94L Angle Bracket (“MB” or “SB”) Flat Bracket (“FB”) Vertical Pipe Vertical Pipe 50022279 46 Horizontal Pipe 50022278 50022277 Horizontal Pipe 50022276 OneWireless XYR 6000 Pressure Transmitter User's Manual Revision 4 6/24/08 6. Maintenance/Repair 6.8. Dimension drawings Revision 4 6/24/08 OneWireless XYR 6000 Pressure Transmitter User's Manual 47
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2008:09:04 10:15:36-07:00 Modify Date : 2008:09:04 10:15:36-07:00 Page Count : 59 Creation Date : 2008:09:04 17:15:36Z Mod Date : 2008:09:04 17:15:36Z Producer : Acrobat Distiller 5.0.5 (Windows) Metadata Date : 2008:09:04 17:15:36ZEXIF Metadata provided by EXIF.tools